P33 snapshotHigh availability:
Hot-swap electronics and battery
Rating: 3000 VA, 2700 Watt
Configuration: 2U, 19” rack
Runtime (minutes):Half / Full load (15 / 5)
Input line cord:Same as rack
# of outlets (receptacles):15*
Options:EBM and SNMP
Voltage and frequency: 208-240 VAC, 50/60 Hz
*P33 has 9 receptacles and rack PDB has 6 receptacles
P33 key features
• High reliability, enhanced availability and serviceability • Hot-swappable electronics and battery increase uptime• Compact 2U rack design preserves valuable rack space• Advanced Battery Management (ABM®) technology
doubles battery service life • Pre-configured design guarantees out-of-box usability
with multiple IBM servers• High power 2700 Watt capacity supports up to 15
devices
P33 key features
• Optional Extended Battery Module (EBMs) prolong battery runtime
• Optional SNMP card allows remote network monitoring, configuration and control
• Wide Buck/Double Boost voltage regulation accommodates severe power problems without using the battery
• Load segments maximize uptime and provide configuration flexibility
• Comprehensive Software Suite CD bundled• User-friendly front panel display
P33 innovative technology
Combines high reliability, availability and serviceability (RAS) in a small footprint with cost-effective ownershipDeveloped for the global market placeMeets the uptime demands in a 24/7 world
P33 applicationsThe P33 was specifically designed, engineered and approved for IBM rack applications
• System p (pSeries and RS/6000)
• System x (xSeries) and other eServers
• Storage and Networking devices
Series 5 protectionThe P33 delivers power protection from power problems that threaten your equipment and data.
Power failure
Power sag
Power surge
Brownout
Over voltage
High-reliability and serviceability
Battery Electronics
Hot-swappable electronics and battery modules
Replacement of electronics or battery module is simple, hot-swappable and user-replaceable. Accessing modules through the front panel, users can safely install new modules without ever powering down connected server and server options. Electronics module weight 30 lb, 14 kg. Battery module weight 42 lb, 19 kg.
Compact 2U design
P33 UPS
FC 6607 EBM
Shown in white for illustration
Limiting the height to 2U saves room for other critical equipment such as servers and disk arrays. EBM is 2U. Up to four EBMs can be added per IBM rack to prolong runtime.
What is it?An intelligent battery-charging technology
Increases battery service life by charging only when neededOptimizes recharge timeIntelligent microprocessor controlled for most accurate advanced failure protectionSleep feature- no unnecessary drain
How it Works:ABM uses a 3-stage charging system:1. The battery is quickly charged to 90% to make
sure the UPS is prepared for the next power outage
2. Second, ABM finishes charging the battery with a more moderate float charge
3. Then, ABM turns the charger off- this prevents the batteries from being overcharged
With ABM the service life of the batteries is significantly increased so customers won’t have to replace them as often as with competitive models
Advanced Battery Management (ABM) Technology
ABM® technology
P33 out-of-box usability
9910 philosophy of a complete package*UPS, power & communication cables, software, mounting hardware and manualsBundled Multi-Server card provides communication with up to three servers
Easy-to-configure and start-upPick the same input power cord as for rack Rack devices connect to P33 using rack interconnect cords (RICs) and rack power distribution bus (PDB)
*P33 package includes: Accessory kit with three IEC-320-C13 to IEC-320-C14 power cords 6 ft (1.8m), three UPS to server communication cables 6 ft (1.8m) and manuals; 4-post rack mounting kit; and, based upon country or application, power cable kit (IBM FC 9851 or 9855).
P33 supports up to 15 devices
15 outlet (receptacle) power connectionsP33 has 9 outletsRack PDB has 6 outlets
Examples of configurations supported• 7015-R50 720 Watts with 2 power connections• 7026-B80 (640) 450 W with 2 power connections• 7026-HA-B80 (640) 1860 W with 10 power connections 7026-H80,
6Hx (660) 965 W with 4 power connections• 7026-HA-H80, 6Hx (660) 2410 W with 10 power connections• 7026-M80 1065 W with 4 power connections• 7046-B50^ (15 ea) 2100 W with 15 power connections
*Maximum: 15 devices each with one power connection; or, 7 devices each with two power connections (non- or dual-redundant). Number of devices support limited to P33 2700 Watt capacity. ^FC 2932 connects P33 as a node in a SNMP network, capable of managing multiple servers.
Extended Battery Module optionThe EBM option allows you to prolong battery runtime to accommodate application or business needs. Features include
•Hot-swappable, user-replaceable modules utilize same type module as P33 -- simplifying service•Identical 2U foot print as P33 •Factory install or option to field upgrade •IBM rack accommodates up to four EBMs and two P33s •Add up to four EBMs per P33
+1 EBM (Half / Full) 61 / 25 Min+2 EBM 103 / 49+3 EBM 146 / 69+4 EBM 190 / 90
•IBM FC 6607, IBM PN 21P7221•Powerware PN 05147156-3901
P33 and one EBM
Shown in white for illustration
ConnectUPS SNMP optionThe ConnectUPS SNMP option is ideal for managing UPSs providing protection for network devices and gives network managers the ability to perform tasks via network or out-of-band (modem) connections. Features include
•Enables network administrators to remotely monitor and reset hung network devices•Ability to remotely control selected power outlets•Compatible with leading SNMP network management software packages (IBM NetView, HP OpenView, SunNet Mgr, etc.) and Powerware’s Software Suite•Automatically records UPS events and alarms•Configurable over the network via BOOTP•Provides automatic dial out to pager or computer using UPSdial software included•Powerware’s PowerMIB and UPS Standard MIB software included•Ethernet (10Mbps) twisted pair
•IBM FC 2932, IBM PN 04N7026, Powerware PN 05146288-3901
SNMP card shownreplaces P33 Multi-Server card
Buck and double boost voltage regulationWidest available input voltage range accommodates severe environmentsTight output voltage -- provides clean power to connected equipmentRegulates output without using the battery -- prolonging battery life
Nominal Voltage +6%
-10%
+20%
-25%Sine wave output Single phase
Load segments maximize uptimePower down sequencing
Extends runtime for critical devicesReboots locked-up devices
Power up sequencingOrderly power up of devices
Scheduled on/off timesTurns off devices for security and power conservation
Three outlet (receptacle) groupsIndependently controlled with LanSafe III software
Bundled management softwareLanSafe: serial, USB, network:Safe shutdown for computers on low battery alarm: up to 63 additional LanSafe members safely shutdown from one LanSafe controller
Email alarms, execute programs, see UPS stateLoad shedding to extend runtime during outageEvent Calendar View, Power Savings CalculatorProvides SNMP proxy for serial or USB UPS’s
Bundled Free
User-friendly front panel display
On
Off/Standby
Test/Alarm reset
Load level LEDs
1. General Alarm 3. Bad Battery/Low Battery 5. Utility LED2. On Battery 4. Site Wiring Fault Indicator
1 2 3 4 5
Shown in white for illustration
Collaterals
Go to www.powerware.com/ibmSelect the Products tabChoose 9910 UPS for System i or System pScroll down to the P33 link
Materials availableTechnical specificationsSizing guidesProduct presentationUser’s manuals
Key elements• High availability: Hot-swap electronics and battery• Supports up to 15 devices: One rack - one P33• Out-of-box usability: 9910 philosophy of a complete package• Options: Extended Battery and SNMP• Compact 2U rack design preserves valuable rack space• Advanced Battery Management® technology doubles battery service
life • Wide Buck/Double Boost voltage regulation accommodates severe
power problems without using the battery• Load segments maximize uptime and provide configuration flexibility• Comprehensive Software Suite CD bundled• User-friendly front panel display