9600-TO-9650 CONVERSION GUIDE - ATM … CONVERSION GUIDE 2 ... Open the ATM control panel and turn...

4
9600-TO-9650 CONVERSION GUIDE TDN 07103-00020B May 2004 COPYRIGHT NOTICE Copyright © Delaware Capital Formation, Inc., 2004. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language, in any form, by any means whatsoever, without the express written permission of Delaware Capital Formation, Inc. DOVER and the DOVER logo are registered trademarks of Delaware capital Formation, Inc., a wholly-owned subsidiary of Dover Corporation. CORPORATE HEADQUARTERS: RMA (RETURN MATERIAL AUTHORIZATION) RETURN ADDRESS: 522 E. Railroad Street 21405 B Street Long Beach, MS 39560 Long Beach, MS 39560 PHONE: (228) 868-1317 FAX: (228) 868-0437 (US and UK Models)

Transcript of 9600-TO-9650 CONVERSION GUIDE - ATM … CONVERSION GUIDE 2 ... Open the ATM control panel and turn...

9600-TO-9650CONVERSION GUIDE

TDN 07103-00020B May 2004

COPYRIGHT NOTICE

Copyright © Delaware Capital Formation, Inc., 2004. All rights reserved. No part of thispublication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translatedinto any human or computer language, in any form, by any means whatsoever, without theexpress written permission of Delaware Capital Formation, Inc. DOVER and the DOVER logoare registered trademarks of Delaware capital Formation, Inc., a wholly-owned subsidiary ofDover Corporation.

CORPORATE HEADQUARTERS: RMA (RETURN MATERIAL AUTHORIZATION)RETURN ADDRESS:

522 E. Railroad Street 21405 B StreetLong Beach, MS 39560 Long Beach, MS 39560PHONE: (228) 868-1317FAX: (228) 868-0437

(US and UK Models)

9600-TO-9650 CONVERSION GUIDE

2

PURPOSE

The following procedure assumes you are converting aModel 9600 Cash Dispenser to a Model 9650 CashDispenser, using the 9600-to-9650 Conversion Kit.

PARTS SUPPLIED

CONVERSION PROCEDURE

1. Open the ATM control panel and turn the powerswitch (on the power supply panel) to the OFF (0)position.

2. Open the vault and disconnect the power and datacables from the rear of the existing dispenser.(Figure 1)

3. Remove the existing dispenser from the slide tray.

4. Remove the slide tray. Press up/down on the sliderelease levers located on each slide to release theslide members. (Figure 2) Pull the slide tray outand remove it from the cabinet.

5. Extend the left side slide rail to its fully extendedposition.Remove the 4 screws holding theouter slidemember to the left side of the cabinet . Repeat theprocedure for the right side. Remove the cabinetslides. (Figure 3)

Figure 1. Power and Data Cable

Figure 2. Power and Data Cable Connectors

Power Cable

Data CableDEILPPUSSTRAP

TIKNOISREVNOCKU0569-ot-006965000-00260:NP

1 87000-11030 tekcarBgnitnuoMedilStfeLdettolS07/0569

1 97000-11030 tekcarBgnitnuoMedilSthgiRdettolS07/0569

2 00000-28030 riaP)Z49060440(edilSmotsuC"81kcohcS

1 78020-00690 ylbmessAylppusrewoPzH05/V032naeporuE0569

1 75000-00690 elbaCataDhceM-ot-JE0469

1 91000-00890 elbaCrewoPCDresnepsiD0569

1 63020-00690 eludoMJEwolleY

2 40100-11030 tekcarBeldnaH04-hceM0469

01 05000-45020 rehsaWhtooTtxe/wdaeHnaPspillihP-wercS8/3X23-8#

6 84000-45020 daeHspillihPssurTcniZwercS8/3x23-8#

8 18000-45020 daeHssurTspillihP01x4#

1 01000-03010 eludoMetirreF

1 38000-30170 launaMsnoitarepO07/0569

4 51000-27030 sparWeiT"6

1 02000-30170 serudecorPedargpUdleiF0569-0069

DEDEENSLOOT

revirDtuN)mm11(.ni-61/7

srevirdwercSspillihP2#dna1#

srevirdwercSdaeHtalFmuideMdnallamS

Figure 3. Screw location for slide rails.

9600-TO-9650 CONVERSION GUIDE

3

6. Install the Left Side Mounting Bracket (03011-00078)using a Phillips screwdriver. Repeat theprocess for the Right Side Mounting Bracket (03011-00079).

7. Install the Schock custom slides to the mountingbrackets and dispenser mechanism. ( 03082-00000)[There are 2 pair of slides. Pull the slides apart.One slide gets mounted to the mounting bracket,the other to the dispenser handle bracket (03011-00104) ]

Slide Mounting BracketSlide

Slide

Handle Bracket

5. Disconnect the 2 cables from the E.J. Unbolt the9600 E.J. from the cabinet and install the 9650 E.J(09600-02036)

6. Reconnect the E.J. to Backplane data cable. (Oneclosest to front of cabinet) Remove the 9600 E.J.to dispenser cable. Connect the 9640/50 E.J toDispenser data cable (09600-00057) to the E.J (Oneclosest to rear of cabinet). Let the other end ofcable rest in cabinet until dispenser is installed.

Dispenser Cable

Bolts

Backplanecable

Electronic Journal (E.J.)

7. Open the Control Panel. Disconnect all cablesconnected to the AC input module located onthe power supply plate. Remove the two screws(upper left/right) that attach the power supplyassembly to the card cage assembly.

Screws

9600-TO-9650 CONVERSION GUIDE

4

8. Pivot the power supply plate down and disconnectthe Phone Line In cable from the connector labeledJ1 on the surge protector board. Disconnect thephone line to backplane cable from the connectoron the backplane labeled J5. Disconnect the powersupply cable connector. Remove the 9600 PowerSupply Assembly from the unit. Disconnect the9600 Dispenser Power Cable plugged into J9 andremove the cable from the unit.

9. Plug the 9650 Dispenser Power Cable (09800-00019) into the connector labeled J9 on thebackplane. There is a polarizing pin on theconnector, so make sure that the connector isproperly aligned with the mating connector on thebackplane before proceed. Route the end of thecable into the cabinet through the oval slot in thetop of the cabinet. Snap the Ferrite Clip onto thecable next to the backplane connector.

13. Slide the 9650 Dispenser Mechanism into thecabinet while viewing the dispenser cables.

14. Connect the 9650 DC Power Cable and EJ DataCable to the left side of the dispenser mechanism.Note: The EJ data cable is connected to the mostforward connector.

DispenserPower Cable

Route end of cable through holein the cabinet

DC Power Connection EJ Communication DataCable

10. Install the 9650 European Power Supply Assembly( 09600-02087) into the card cage. Reverse thesteps in Step 8. Make sure the new Power Supplybeing installed has the correct part number. ( 9600-2087 is European P.S.)

11. Close the power supply to the card cage and securewith the 2 screws. Reconnect the cables connectedto the AC input module located on the power supplyplate.

J5

Powr supply cableconnectorJ9

J1

12. Use the tie wraps provided to secure thedispenser power cable to the cabinet.