![Page 1: 9510-9515-9516 (ENG - 090611) · Formula linking flow Q (in l/s) and theoretical valve headloss ∆p (in kPa). Kv depends on handwheel position as indicated on table. 19,59 29,72](https://reader036.fdocuments.us/reader036/viewer/2022071013/5fcb1cfe8ac66078d535d22a/html5/thumbnails/1.jpg)
Fixed orifice DZR brass double regulating valveThreaded F/F (ISO 228/1 for DN15 and DN20, ISO7/1 Rp above)Olive and nut mounting kit for European copper tubing (EN1057) on request:● DN15, kit for 15mm pipe● DN20, kit for 22mm pipeDesign according BS7350Tolerance on nominal Kvs ±3% (test according BS7350)Available on following versions:● Fig. 9510, with threaded and plugged drains (¼" ISO 7/1Rp)
(allow later mounting of test points)● Fig. 9515, with test points● Fig. 9516, with test points (high pressure TP with drain)Gost compliant
PN25 (Max 25bar up to 80°C, max 20bar at 100°C)
Working conditions:● Water: -10°C to +130°C
below 0°C only for water with added antifreezing fluidsover 100°C only for water with additives avoiding boiling
N.1234567891011121314151617
1Only on DN32, DN40 and DN50
Test point / plug DZR Brass EN12164 CW602NTie Polyprop. (blue / red) -
Handwheel ABS (blue) -Nut Zinc plated steel EN10025 Fe42
Screw Steel -
Disc1
Disc O-ring1
Disc stem
DZR Brass
Stem O-ring EPDM Perox
EN12164 CW602N
EN12164 CW602NEN12165 CW602N
Gasket disc PTFE -
Body DZR BrassBalancing cone DZR Brass
Part Material NormVenturi insert DZR Brass EN12164 CW602N
-EN12164 CW602N
-
EPDM PeroxDZR Brass
Union1 DZR Brass EN12165 CW602NStem Brass EN12164 CW617N
Bonnet DZR Brass EN12164 CW602NStop spring ring Spring steel -
951x951x951x951xFixed Orifice DZR Brass Double
Regulating Valve
Via Circonvallazione, 1013018 Valduggia (VC), Italy
Tel: +39 0163 47891Fax: +39 0163 47895
www.vironline.com
valvoindustria ing.Rizzio s.p.a.
Description
Part List
2
1
5
4
3
10
9
8
7
6
11
12
13
14
15
16
17
For Fig. 9516
For Fig. 9510
For Fig. 9515
090611
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
![Page 2: 9510-9515-9516 (ENG - 090611) · Formula linking flow Q (in l/s) and theoretical valve headloss ∆p (in kPa). Kv depends on handwheel position as indicated on table. 19,59 29,72](https://reader036.fdocuments.us/reader036/viewer/2022071013/5fcb1cfe8ac66078d535d22a/html5/thumbnails/2.jpg)
Formula linking flow Q (in l/s)and ∆p measured at test points(in kPa).Minimum flow that can bemeasured for each diametermay be calculated by using inthe formula minimum ∆p thatcan be measured by usedmanometer.Valves are anyway designedfor best performances whenused on range previouslysuggested and as indicated byBS7350.
0,017-0,045015LF ½" 103,0 87,82 17,5 70 22 5562 0,031-0,074
17,5 70 22 5582015ULF ½" 103,0 87,82
1,520-3,5104
1ISO 228/1 for DN15 and DN20, ISO7/1 Rp above2For olive and nut version length 109,2mm, weight +63g3For olive and nut version length 119,1mm, weight +65g4Suggested flow range applicability (BS7350).
If used with measuring manometers different from those proposed by VIR please verify that sensibility of themeasuring device is compatible with indicated minimum flow (see flow measurement paragraph)
29,2 70 22 2064050 2" 135,6 145,3
0,540-1,2504
040 1½" 125,4 127,0 24,8 70 22 1446 0,810-1,8804
24,8 70 22 1191032 1¼" 123,3 117,5
0,138-0,3254
025 1" 103,0 100,0 22,5 70 22 751 0,258-0,6034
5502 0,062-0,1484
020 ¾" 103,0 95,93 19,0 70 22 6203
(l/s)B ØV
015 ½" 103,0 87,82 17,5 70 22
(mm) (mm) (mm) (g)I WgtDN G1 H L Flow range
(mm) (mm)
Dimensions
Via Circonvallazione, 1013018 Valduggia (VC), Italy
Tel: +39 0163 47891Fax: +39 0163 47895
www.vironline.com
Flow Measurement
090611
Q (flow)
∆pTP
High pressure test pointLow pressure test point
36
TPventurivs pK
Q∆⋅
=
10,000 100,000
DN15,
100,00
10,00
1,00
0,10
DN20,
DN25,
DN32,
DN40,
DN50,
∆pT
P [k
Pa]
Flow [l/s]0,1000,001 1,0000,010
DN15ULF,
DN15LF,
Kvs venturi 0,55
Kvs venturi 1,15
Kvs venturi 2,80
Kvs venturi 5,33
Kvs venturi 9,72
Kvs venturi 20,25
Kvs venturi 30,23
Kvs venturi 55,07
H
ØV
G
BL
I
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
![Page 3: 9510-9515-9516 (ENG - 090611) · Formula linking flow Q (in l/s) and theoretical valve headloss ∆p (in kPa). Kv depends on handwheel position as indicated on table. 19,59 29,72](https://reader036.fdocuments.us/reader036/viewer/2022071013/5fcb1cfe8ac66078d535d22a/html5/thumbnails/3.jpg)
Formula linking flow Q (in l/s) andtheoretical valve headloss ∆p (in kPa).Kv depends on handwheel position asindicated on table.
19,59 29,720,523 0,852 1,92 3,67 6,24 - - -
1,89 3,51 6,14 12,54
18,63 27,440,515 0,800 1,83 3,24 5,88 12,40 19,17 28,42
1,76 2,93 5,74 12,06
16,34 24,840,500 0,747 1,63 2,54 5,61 11,58 17,88 26,44
1,38 2,13 5,27 10,56
12,29 21,730,456 0,643 1,14 1,94 4,87 9,05 14,13 23,06
1,02 1,72 4,57 7,92
7,78 17,450,442 0,579 0,95 1,40 4,18 6,76 10,45 20,20
0,86 1,20 3,57 5,42
4,82 12,370,335 0,433 0,78 1,08 3,01 4,54 5,71 14,39
0,70 0,97 2,70 4,182,44 3,88 4,29 10,540,286 0,341 0,62 0,78
3,12 6,540,53 0,58 2,09 3,42 3,69 8,350,41 0,47 1,73 2,92
040 0500,153 0,138 0,41 0,41 1,47 2,56 2,72 5,36
To obtain the best performances valve must be installed on a pipe with its samenominal size preceded and followed by straight pipe lengths as per figureindications.
0,381
Handwheel position
Kv (m3/h @ 1bar)015ULF
0,5015LF 015 020 025 032
0,71,0 0,245 0,248
0,178 0,161
0,771
1,31,5
0,447 0,602
0,487 0,716
0,385 0,507
0,307
0,824
1,72,02,32,52,73,03,33,5 0,5143,74,04,4
0,522
Headloss calculation
Min 5xDN(10xDN if installed
on pump outlet)Min 2xDN
Installation
Via Circonvallazione, 1013018 Valduggia (VC), Italy
Tel: +39 0163 47891Fax: +39 0163 47895
www.vironline.com
Q (flow) ∆p(headloss)
236
⋅=∆VK
Qp
Drawings, photos and data contained in this card are provided for information only. VIR reserves the right to change them without notice.
![Page 4: 9510-9515-9516 (ENG - 090611) · Formula linking flow Q (in l/s) and theoretical valve headloss ∆p (in kPa). Kv depends on handwheel position as indicated on table. 19,59 29,72](https://reader036.fdocuments.us/reader036/viewer/2022071013/5fcb1cfe8ac66078d535d22a/html5/thumbnails/4.jpg)
1)
2)
3)
4)
In the example for a design flowrate of 2m3/h and design ∆p 15kPa handwheel position of 2,9 is
determined for a DN25 valve
By using diagram above is possible toesteem the presetting position of the valvewith given design flowrate and headloss:
draw a straight line joining design flowrateand design headloss;determine design Kv value as intersectionof drawn line and Kv axis;draw a straight horizontal line fromintersection previously identified and thespecific valve DN Axis;intersection determines handwheel position to use for presetting.
Via Circonvallazione, 1013018 Valduggia (VC), Italy
Tel: +39 0163 47891Fax: +39 0163 47895
www.vironline.com
Presetting