9/30/2008 AC 150/5340-30D Appendix 1 179 COPPER-WIRE, AMERICAN WIRE GAUGE B&S B&S GAUGE NO. OHMS PER 1 000 FEET 25 ° C., 77 ° F. AREA CIRCULAR MILS DIAMETER IN MILS AT 20 ° C. APPROXIMATE POUNDS PER 1,000 FEET (305 m) 2 0.1593 66,370 257.6 201 4 0.2523 41,740 204.3 126 6 0.4028 26,250 162.0 79 8 0.6405 16,510 128.5 50 10 1.018 10,380 101.9 31 12 1.619 6,530 80.81 20 Calculations 1. To determine the AWG size wire necessary for a specific connected load to maintain the proper voltage for each miscellaneous lighting visual aid, use the above table and Ohms Law R E I = as follows: a. Example. What size wire will be necessary in a circuit of 120 volts AC to maintain a 2 percent voltage drop with the following connected load which is separated 500 feet from the power supply? (1) Lighted Wind Tee Load - 30 lamps, 25 watts each = 750 watts. (2) The total operating current for the wind tee is amperes volts watts I 25 . 6 120 750 = = = . (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with a separation of 500 feet (1,000 feet (305 m) of wire used) to maintain not more than 2.4 volts drop is ohms amperes volts I E R 384 . 0 25 . 6 4 . 2 = = = per 1,000 feet (305 m) of wire. (5) From the above table, obtain the wire size having a resistance per 1,000 feet (305 m) of wire that does not exceed 0.384 ohms per 1,000 feet (305 m) of wire. The wire size that meets this requirement is No. 4 AWG wire with a resistance of 0.2523 ohms per 1,000 feet (305 m) of wire. (6) By using No. 4 AWG wire in this circuit, the voltage drop is E=IR=6.25-amperes x 0.2523 ohms=1.58 volts which is less than the permissible voltage drop of 2.4 volts. 2. Where it has been determined that it will require an extra large size wire for homeruns to compensate for voltage drop in a 120-volt power supply, one of the following methods should be considered. a. A 120/240-volt power supply. b. A booster transformer, in either a 120-volt or 120/240-volt power supply, if it has been determined its use will be more economical. Figure 68. Calculations for Determining Wire Size.

Transcript of 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun...

Page 1: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

9/30/2008 AC 150/5340-30D Appendix 1

179

COPPER-WIRE, AMERICAN WIRE GAUGE B&S B&S

GAUGE NO.

OHMS PER 1 000 FEET 25°C., 77°F.

AREA CIRCULAR

MILS

DIAMETER IN MILS AT 20°C.

APPROXIMATE POUNDS PER

1,000 FEET (305 m)2 0.1593 66,370 257.6 201 4 0.2523 41,740 204.3 126 6 0.4028 26,250 162.0 79 8 0.6405 16,510 128.5 50

10 1.018 10,380 101.9 31 12 1.619 6,530 80.81 20

Calculations

1. To determine the AWG size wire necessary for a specific connected load to maintain the proper voltage

for each miscellaneous lighting visual aid, use the above table and Ohms Law REI = as follows:

a. Example. What size wire will be necessary in a circuit of 120 volts AC to maintain a 2 percent voltage drop with the following connected load which is separated 500 feet from the power supply?

(1) Lighted Wind Tee Load - 30 lamps, 25 watts each = 750 watts.

(2) The total operating current for the wind tee is amperesvoltswattsI 25.6

120750

=== .

(3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts.

(4) Maximum resistance of homerun wires with a separation of 500 feet (1,000 feet (305 m) of wire

used) to maintain not more than 2.4 volts drop is ohmsamperesvolts

IER 384.0

25.64.2

=== per

1,000 feet (305 m) of wire.

(5) From the above table, obtain the wire size having a resistance per 1,000 feet (305 m) of wire that does not exceed 0.384 ohms per 1,000 feet (305 m) of wire. The wire size that meets this requirement is No. 4 AWG wire with a resistance of 0.2523 ohms per 1,000 feet (305 m) of wire.

(6) By using No. 4 AWG wire in this circuit, the voltage drop is E=IR=6.25-amperes x 0.2523 ohms=1.58 volts which is less than the permissible voltage drop of 2.4 volts.

2. Where it has been determined that it will require an extra large size wire for homeruns to compensate for voltage drop in a 120-volt power supply, one of the following methods should be considered.

a. A 120/240-volt power supply.

b. A booster transformer, in either a 120-volt or 120/240-volt power supply, if it has been determined its use will be more economical.

Figure 68. Calculations for Determining Wire Size.

Page 2: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

AC 150/5340-30D 9/30/2008 Appendix 1

180

Figure 69. Typical Automatic Control.

Page 3: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

9/30/2008 AC 150/5340-30D Appendix 1

181

Figure 70. 120-Volt AC and 48-Volt DC Remote Control.

Page 4: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

AC 150/5340-30D 9/30/2008 Appendix 1

182

Figure 71. Typical Structural Beacon Tower.

Page 5: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

9/30/2008 AC 150/5340-30D Appendix 1

183

L-802A AIRPORT ROTATING BEACON

OPTIONAL 8' LONGLIGHTNING RODS (3)

52'-'6"NOMINAL BEACONMOUNTING HEIGHT

51'-0"NOMINAL

7' Ø BEACON BASKET

HANDHOLE 18" ABOVE BASE PLATE ANOTHER AT25' ABOVE BASE PLATE LEVEL

BEACON POLE FOUNDATION

12"

CLIMBING RUNGS

CLIMBER SAFETY DEVICE (TOP)

CLIMBER SAFETY DEVICE (BOTTOM)

24"

BEACON POLE PAINTING DETAIL(ITEMS NOT SHOWN

OMITTED FOR CLARITY)

7'-6" APPROX ORANGE STRIPE

7'-6" APPROXWHITE STRIPE

Figure 72. Typical Tubular Steel Beacon Tower.

Page 6: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

AC 150/5340-30D 9/30/2008 Appendix 1

184

L-802A AIRPORT ROTATING BEACON

OPTIONAL 8' LONGLIGHTNING ROD

55'-0"NOMINAL BEACONMOUNTING HEIGHT

HANDHOLE

HANDHOLE

HAND POWERED WINCHWITH REMOVABLEHAND CRANK (HIDDEN)

BEACON POLEHINGE LOCATION

BEACON POLEFOUNDATION

BEACON MOUNTING PLATE

BEACON POLE PAINTING DETAIL(ITEMS NOT SHOWN

OMITTED FOR CLARITY)

7'-10" APPROX ORANGE STRIPE

7'-10" APPROXWHITE STRIPE

Figure 72a. Typical Airport Beacon Tip-Down Pole

Page 7: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

9/30/2008 AC 150/5340-30D Appendix 1

185

Figure 73. Typical Pre-fabricated Beacon Tower Structure.

Page 8: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

AC 150/5340-30D 9/30/2008 Appendix 1

186

SUPPLEMENTAL WIND CONE CANNOT BE INSTALLED WITHIN THE RSA.

SUPPLEMENTAL WIND CONE CANNOT BE INSTALLED WITHIN THE OFA UNLESS THERE ISOPERATIONAL NEED. DOCUMENTATION MUST BE PROVIDED TO EXPLAIN REASON FORLOCATION. MUST BE MOUNTED ON FRANGIBLE STRUCTURE.

PREFERRED WIND CONE LOCATION OUTSIDE OF OFA.

OBJECT FREE AREA (OFA)

RUNWAY SAFETY AREA (RSA)

1,000 FT [305 M]NOTES:

SEE AC 150/5300-13 FOR DETAILED INFORMATION ABOUT THE LENGTH AND WIDTH OF THE RSA AND OFA - DIMENSIONS OF BOTHAREAS ARE DEPENDENT UPON THE AIRPLANE DESIGN GROUP AND AIRCRAFT APPROACH CATEGORY.

THE OBSTACLE FREE ZONE (OFZ) IS NOT SHOWN. SEE AC 150/5300-13 FOR DETAILED INFORMATION. THE SUPPLEMENTAL WINDCONE MUST NOT PENETRATE THE OFZ.

THE PREFERRED LOCATION FOR THE SUPPLEMENTAL WIND CONE LOCATION IS BETWEEN 0 AND 1,000 FT FROM THE RUNWAY END.

2.

3.

1.

Figure 74. Typical Location of Supplemental Wind Cone.

Page 9: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

9/30/2008 AC 150/5340-30D Appendix 1

187

Figure 75. Externally Lighted Wind Cone Assembly (Frangible).

Page 10: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

AC 150/5340-30D 9/30/2008 Appendix 1

188

1000

'+1

00'

-0'14

00'

+100

'-0

'

7 C

EN

TER

LIN

E BA

RS

(WH

ITE)

200

' SPA

CIN

G S

EE

NO

TE 9

+100

'-0

'

20'

20'

RU

NW

AYE

XTE

ND

ED

RU

NW

AY

CEN

TER

LIN

E

SYM

BOLS

:E

XIST

ING

RU

NW

AY E

DG

E LI

GH

TSE

XIST

ING

RU

NW

AY

THR

ESH

OLD

LIG

HTS

STE

ADY

BU

RN

ING

APP

RO

ACH

LIG

HTS

SE

QU

EN

CE

D F

LASH

ING

LIG

HTS

NO

TES

:

1. T

HE

OP

TIM

UM

LO

CAT

ION

OF

THE

APP

RO

ACH

LIG

HTS

IS IN

A H

OR

IZO

NTA

L

PLA

NE

AT

RU

NW

AY E

ND

ELE

VATI

ON

. PR

OV

IDE

AT L

EAST

TH

RE

E

CO

NS

EC

UTI

VE

LIG

HT

BAR

STA

TIO

NS

IN A

SLO

PIN

G S

EGM

EN

T O

F TH

E

SYS

TEM

. TH

E S

LOP

ING

SEG

ME

NT

MA

Y S

TAR

T A

T TH

E FI

RST

LIG

HT

BAR

A

ND

EXT

END

TO

TH

E E

ND

OF

SYS

TEM

OR

MA

Y BE

PR

EC

EDED

BY

A

HO

RIZ

ON

TAL

SEG

ME

NT

OR

FO

LLO

WE

D B

Y E

ITH

ER

A H

OR

IZO

NTA

L O

R

NEG

ATI

VE S

LOP

ING

SEG

MEN

T.

2. A

MA

XIM

UM

2 P

ER

CEN

T U

PW

AR

D L

ON

GIT

UD

INA

L S

LOP

E TO

LER

AN

CE

M

AY B

E U

SED

TO

RA

ISE

TH

E L

IGH

T PA

TTER

N A

BOV

E O

BJE

CTS

WIT

HIN

IT

S A

REA

.

3. A

MA

XIM

UM

1 P

ERC

EN

T D

OW

NW

ARD

LO

NG

ITU

DIN

AL

SLO

PE

TOLE

RA

NC

E

MA

Y B

E U

SED

TO

RE

DU

CE

THE

HEI

GH

T O

F SU

PPO

RTI

NG

STR

UC

TUR

ES.

4. A

LL S

TEAD

Y B

UR

NIN

G A

ND

FLA

SHIN

G L

IGH

TS A

RE

AIM

ED W

ITH

TH

EIR

B

EAM

AXE

S P

ARA

LLE

L TO

TH

E R

UN

WAY

CEN

TER

LIN

E A

ND

INTE

RC

EPT

ING

A

N A

SSU

ME

D 3

' GLI

DE

SLO

PE (I

NTE

RC

EP

TIN

G T

HE

RU

NW

AY

1000

FE

ET

F

RO

M T

HE

LAN

DIN

G T

HR

ESH

OLD

) AT

A H

OR

IZO

NTA

L D

ISTA

NC

E O

F

160

0 FE

ET IN

AD

VAN

CE

OF

THE

LIG

HT.

5.

ALL

OBS

TRU

CTI

ON

S A

S D

ETE

RM

INED

BY

APPL

ICAB

LE C

RIT

ERIA

(14C

FR P

AR

T 77

)

FO

R D

ETE

RM

ININ

G O

BS

TRU

CTI

ON

S T

O A

IR N

AV

IGA

TIO

N A

RE

LIG

HTE

D

A

ND

MAR

KE

D A

S R

EQ

UIR

ED

.

6.

ALL

STE

ADY

BU

RN

ING

AN

D F

LASH

ING

LIG

HTS

IN T

HE

SYS

TEM

EM

IT W

HIT

E LI

GH

T.

7.

INTE

NS

ITY

CO

NTR

OL

IS P

RO

VID

ED

FO

R T

HE

STE

AD

Y B

UR

NIN

G L

IGH

TS.

8.

THE

THR

EE

FLAS

HIN

G L

IGH

TS F

LAS

H IN

SEQ

UE

NC

E.

9.

THE

MA

LS L

IGH

T B

AR C

LOS

EST

TO T

HE

RU

NW

AY T

HR

ESH

OLD

IS L

OC

ATE

D A

T A

D

ISTA

NC

E O

F 20

0'

.

ALL

OTH

ER L

IGH

T B

ARS

SH

OU

LD B

E IN

STAL

LED

AT

200'

INTE

RV

ALS

WIT

H A

±20

' TO

LER

ANC

E A

T E

ACH

LIG

HT

BAR

STA

TIO

N.

THE

ABO

VE T

OLE

RAN

CE

S M

AY

BE U

SED

WH

ER

E IT

IS IM

PR

ACTI

CAL

TO

INST

ALL

LIG

HT

BAR

S A

T TH

E O

PTI

MU

M L

OC

ATIO

NS.

10. T

HE

MIN

IMU

M L

AN

D R

EQ

UIR

EM

ENTS

FO

R M

ALS

F IS

AN

AR

EA 1

600'

IN

LE

NG

TH B

Y 4

00' W

IDE

.

11. P

RO

VID

E A

CLE

AR

LIN

E O

F SI

GH

T TO

ALL

LIG

HTS

OF

THE

SYS

TEM

FR

OM

AN

Y

P

OIN

T O

N A

SU

RFA

CE

1 2 ' B

ELO

W A

3' G

LID

E P

ATH

, IN

TER

SEC

TIN

G T

HE

RU

NW

AY

10

00' F

RO

M T

HE

LA

ND

ING

TH

RE

SH

OLD

.

±20'

200'

200'

+100

'-0

'

Figure 76. Typical Layout for MALSF.

Page 11: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

9/30/2008 AC 150/5340-30D Appendix 1

189

Figure 77. Typical Layout for Runway End Identifier Lights (REILs).

Page 12: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

AC 150/5340-30D 9/30/2008 Appendix 1

190

300 ±25'

300 ±25'

300 ±25'

300 ±25'

300 ±25'

1,200 ±100'

STROBE NUMBER 3 OPTICAL HEAD(POWER SUPPLY REMOTELY INSTALLED)

+35'-0'

REMOTE LOCATION (OPTIONAL) FORPOWER SUPPLY UNIT OF STROBE NUMBER 3

AS REQUIRED

TYPICAL LOCATION OF SYSTEM POWER AND CONTROL UNIT

150' MAXIMUM

150' 40'

ODAL LIGHTS 6A AND 6B ARE IN LINE WITH RUNWAY THRESHOLDEXISTING RUNWAY

EDGE LIGHTING SYTEM 6A6B

5

4

3

2

1

CLRUNWAY

EXTENDED

OMNIDIRECTIONAL STROBE LIGHT(OPTICAL HEAD AND POWER SUPPLY UNIT)TYPICAL FOR UNITS 1, 2, 4, 5, 6A AND 6B

Figure 78. Typical ODALS Layout

Page 13: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

9/30/2008 AC 150/5340-30D Appendix 1

191

THE VISUAL GLIDE PATH ANGLE IS THE CENTER OF THE ON-COURSE ZONE, AND IS A NOMINAL 3 DEGREES WHEN MEASUREDFROM THE HORIZONTAL SURFACE OF THE RUNWAY.

A. FOR NON-JET RUNWAYS, THE GLIDE PATH MAY BE RAISED TO 4 DEGREES MAXIMUM TO PROVIDE OBSTACLE CLEARANCE.

B. IF THE PAPI GLIDE PATH IS CHANGED TO A HIGHER ANGLE FROM THE NOMINAL 3 DEGREES, IT MUST BE COMMUNICATED IN A NOTICE TO AIRMAN (NOTAM) AND PUBLISHED IN THE AIRPORT FACILITY DIRECTORY.

PAPI OBSTACLE CLEARANCE SURFACE (OCS).

A. THE PAPI OCS PROVIDES THE PILOT WITH A MINIMUM APPROACH CLEARANCE.

B. THE PAPI MUST BE POSITIONED AND AIMED SO NO OBSTACLES PENETRATE ITS SURFACE.(1) THE OCS BEGINS 300 FEET [90M] IN FRONT OF THE PAPI SYSTEM.(2) THE OCS IS PROJECTED INTO THE APPROACH ZONE ONE DEGREE LESS THEN AIMING ANGLE OF THE THIRD LIGHT

UNIT FROM THE RUNWAY FOR AN L-880 SYSTEM, OR THE OUTSIDE LIGHT UNIT FOR AN L-881 SYSTEM.

NOTES:

1.

2.

DISTANCE FROM THRESHOLD CHOSENTO GIVE CORRECT TCH AND OCS

PAPI(4 OR 2 LIGHTUNITS)

OBSTACLE CLEARANCESURFACE (OCS)BEGINS*

PAPI OCS ANGLE = LOWEST ON-COURSE AIMING ANGLE - 1 DEGREE

THRESHOLD CROSSING HEIGHT (TCH) TABLE 1.

OBSTACLE CLEARANCE

LOWEST ON-COURSE

SURFACE (OCS)*

AIMING ANGLE*300 FEET

50 FEET +10-0

20 TO 30 FEET

4 MILE RADIUS

10°

10°

Figure 79. PAPI Obstacle Clearance Surface.

Page 14: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

AC 150/5340-30D 9/30/2008 Appendix 1

192

(1) Above correct glide path All lamps white.

(2) Slightly above correct glide path. 3 white, 1 red.

(1) Above the correct glide path: 2 white lamps.

(3) On the correct glide path. Two white, two red.

(4) Slightly below the correct glide path. 1 white, 3 red.

(2) On the correct glide path: 1 white, 1 red.

(5) Below the correct glide path: All red.

(3) Below the correct glide path: Two red lamps.

Type L-880 Type L-881

NOTE: The PAPI is a system of either four or two identical light units placed on the left of the runway in a line perpendicular to the centerline. The boxes are positioned and aimed to produce the visual signal shown above.

Figure 80. PAPI Signal Presentation.

10

10

10

10

10

10

10

10

Page 15: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

9/30/2008 AC 150/5340-30D Appendix 1

193

REFERENCE PLANE

AIMING ANGLE OR

VISUAL APPROACH PATH

TCH

T

RUNW AY

D1

d

IDEAL RRP

RRP

e

θ

θ

e

RRP

IDEAL RRP

d

D1

RUNW AY

T

TCH

AIMING ANGLE OR

VISUAL APPROACH PATH

REFERENCE PLANE

Siting station displaced toward threshold

ideal (zero gradient) distance from threshold

runway longitudinal gradient

threshold crossing height

threshold

elevation difference between threshold and RRP

runway reference point (where aim ing angle or visual approach path intersects runway profile)

adjusted distance from threshold

aim ing angle

percent slope of runway = e/dS =

=

d =

RRP =

e =

T =

TCH =

RW Y =

D1 =

θ

SYMBOLS:

Siting station displaced from threshold

d =TCH

- Sθtan

S

S

(S is used in decimal form in the equations)

d =TCH + e

θtan

Figure 81. Correction for Runway Longitudinal Gradient.

Page 16: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

AC 150/5340-30D 9/30/2008 Appendix 1

194

Figure 82. General Wiring Diagram for MALSF with 120-Volt, AC Remote Control.

Page 17: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

9/30/2008 AC 150/5340-30D Appendix 1

195

Figure 83. Typical Wiring Diagram for MALSF Controlled from Runway Lighting Circuit.

Page 18: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

AC 150/5340-30D 9/30/2008 Appendix 1

196

Figure 84. Typical Field Wiring Circuits for MALSF.

Page 19: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

9/30/2008 AC 150/5340-30D Appendix 1

197

Figure 85. Typical Installation Details for Frangible MALS Structures – 6 foot (1.8 m) Maximum.

Page 20: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

AC 150/5340-30D 9/30/2008 Appendix 1

198

Figure 86. Typical Wiring for REILs Multiple Operation

Page 21: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

9/30/2008 AC 150/5340-30D Appendix 1

199

Figure 87. Typical Wiring for REIL Series Operation

Page 22: 9/30/2008 AC 150/5340-30D Appendix 1 COPPER-WIRE, … · (3) Permissible voltage drop for homerun wire is 120 volts x 2% = 2.4 volts. (4) Maximum resistance of homerun wires with

AC 150/5340-30D 9/30/2008 Appendix 1

200

Figure 88. FAA L-880 Style B (Constant Current) System Wiring Diagram.