901-KIFA Kifaru Ground ORDER No: FIXINGwicksteed.co.uk › wp-content › uploads › 2016 › 11...
Transcript of 901-KIFA Kifaru Ground ORDER No: FIXINGwicksteed.co.uk › wp-content › uploads › 2016 › 11...
-
Complied by
Date
ISSUEECNDATESIGN
CUSTOMER: FIXING:ORDER No:
AB
30/04/12
901-KIFA Kifaru Ground
01655
01/05/12AB
11663
19/07/12AB
2
Minor30/10/13
DB
-
Complied by
Date
ISSUEECNDATESIGN
CUSTOMER: FIXING:ORDER No:
AB
30/04/12
901-KIFA Kifaru Ground
1525 750
350
75
044
5
1993
600
300
All foundations 300 x 300unless otherwise stated
All foundations 375 deepunless otherwise stated
750750
1440
1586
1050 x 950 DEEP
500
11663
19/07/12AB
01655
01/05/12AB
2
Minor30/10/13
DB
-
Complied by
Date
ISSUEECNDATESIGN
CUSTOMER: FIXING:ORDER No:
AB
30/04/12
901-KIFA Kifaru Ground
1600
3350
2000
2200 1100 550 3100
450
555
0950
1050 2850 3050
2775
2330
695
0
6950
Safety Surfacing38m² of 40mm wetpourwith 23m edging
R2200
R1500
R23
00
R1800
R2000
R10
00 R10001
166319/07/12
AB
01655
01/05/12AB
2
Minor30/10/13
DB
-
Complied by
Date
ISSUEECNDATESIGN
CUSTOMER: FIXING:ORDER No:
AB
30/04/12
901-KIFA Kifaru Ground
302
5
2350
70007500
Safety Surfacing44m² of 33mm tileswith 27m edging
11663
19/07/12AB
01655
01/05/12AB
2
Minor30/10/13
DB
-
Complied by
Date
ISSUEECNDATESIGN
CUSTOMER: FIXING:ORDER No:
AB
01/05/12
901-KIFA Kifaru Ground
55050
500
7500
7500
Safety Surfacing34 grassmats (1m x 1.5m)
11663
19/07/12AB
01655
01/05/12AB
2
Minor30/10/13
DB
-
Complied by
Date
ISSUEECNDATESIGN
CUSTOMER: FIXING:ORDER No:
AB
01/05/12
901-KIFA Kifaru Loose-fill
28
252375
180
03850
1400
70
50
1400 2000 950 1600 1100
1800 3450 1800
180
03
200
1100
950
7050
Safety Surfacing42m² of loose-fill areawith 24.5m edging
11663
19/07/12AB
01655
01/05/12AB
2
Minor30/10/13
DB
-
Complied by
Date
ISSUEECNDATESIGN
CUSTOMER: FIXING:ORDER No:
AB
01/05/12
901-KIFA Kifaru Ground
90165Ramp c/w handrailsand panels
90154Curved climbingwall
90154Curved climbing wall
90153Double tower
90151Quadrant tower
90122Metal barrier(Below deck)
90110Double arch bridge
90105Double widthslide
11663
19/07/12AB
01655
01/05/12AB
2
Minor30/10/13
DB
90156Monkey pole slider
-
SPECIFICATION
INSTALLATION INSTRUCTIONS
Note
Note
PROD. CODE
SIZE
AGE RANGE
F/ FALL HEIGHT
HEAVIEST PART
TOTAL WEIGHT
Tropica
Double Width Slide90105
Up to 8 years
1200mm
62 Kg Approx
90 Kg Approx
90105Page 1 of 5
1980 x 1550 x 3122mm
Chute made from 2mm stainless steel sheet.Guardrail made from 32mm nominal bore tube to BS 1387.Pedestals made from circular hollow section to BS 4848.Fixings are anti-vandal and plated for weather protection.Welds are copper free conforming to 2901 AIB for mild steel.Low lead polyester powder paint to BS EN 71.
1. Read all instructions thoroughly before commencing installation of unit.
2. Do not tighten fastenings until the unit is completely assembled.
3. Excavate foundations as per the foundation plan.
4. Place pedestals in the foundations and prop up in position.
5. Ensuring pedestals are plumb, square and upright, and at the correct height and centre of thedimensions, backfill foundations with concrete.
6. Allow 48 hours of drying time before fixing slide to pedestals.
M8 bolts to be torqued to 18 Nm (13lbft). M10 bolts to be torqued to 34 Nm (25lbft).M12 bolts to be torqued to 55 Nm (40lbft). All protruding screw threads to be peened over to remove sharpedges. Lifting aid will be required when installing this peice of equipment.
All installation aids to be removed before first use!
In accordance with 6.1.3 EN1176-1:2008 we recommend that slides do notface south or near due south due to heat build up.
-
90105
Page 2 of 5
Foundation Detail(Care must be taken under abnormal conditions)
15861443
1050
500
TOWER
TOWER
875
875
Finished Surface Level
Brick
Underside of slide runout tofinished surface level shall be amaximum dimension of 200mm
40
0B
AR
K
475
47
5
300
Foundation Detail:Ground Fixed 1050 x 500 x 875mm
Foundation Detail:Bark Fixed 1050 x 500 x 475mm
-
90105
Page 3 of 5
Surfacing & Free Space Detail
R1000R1000
R1500R1500
FREE
SPACE
FREE
SPACE
3
5
11
7
4
5
11
7
Fixing pedestals to chute:1. To fit pedestals to chute use M12 x 25mm Lg PentButton Head Screws, placing a M12 fibre washer eitherside of the pedestal top plate.
2. Ensure spragging iron is in place before.
-
90105
Page 4 of 5
6
1
End Plug DetailInsert the two plastic end plugs into slide barrierspigots before securing to slide and tower.
8
12
8
1
Fixing Detail to TowerAttach slide and barrier to tower using M10 x25mm Lg pent button head screws and M10Wicksteed washers.
13
10
-
REV
ECN
SIG.
DATE:
COMPILED
DATE:
90105
Page 5 of 5
MH
13/11/01
Parts ListDESCRIPTIONPART NUMBERQTYITEM
DOUBLE WIDTH SLIDE BARRIER90105-0211
CHUTE ASSEMBLY90105-0112
PEDESTAL SUPPORT LEG - RUNOUT4013-03823
PEDESTAL SUPPORT LEG - MIDDLE4013-03724
SPRAGGING IRON3031-01145
END PLUG (1¼ NB)2611-00526
M12 Fibre Washer2571-013327
Wicksteed Washer2215-51968
M12 Plain Washer2215-50929
M10 Safety Fastener2177-002210
M12 x 25 Pent Button Head2176-1761611
M10 x 50 Pent Button Head2176-129212
M10 x 25 Pent Button Head2176-126413
NEW
1396
MH
13/11/01
1
Minor
PG
29/04/02
All spare parts are available from Wicksteed Playscapes on request
2
Minor
DB
12/03/14
3
Minor
DB
15/07/15 18/08/15
MC
4
Minor
-
SPECIFICATION Bridge: Made from 250 and 20 mm Nominal bore tube to BS 1387. Floor Panel: Made from Durbar 3 mm thick Chequer plate Logs: Made from recycled plastic. Fasteners: Non standard anti-vandal, plated for weather protection. Finish: Low lead polyester powder paint to BSEN 71 Part 3
INSTALLATION INSTRUCTIONS 1 Read installation instructions through before commencing erection of unit. 2 Do NOT tighten fastenings until the unit is completely assembled
DELIVERY LIST
Part No. Description Qty
90110-01 Double Arch Bridge Assembly 1
- Fixings pack 1
TROPICA DOUBLE ARCH BRIDGE
PROD CODE: 90110
SIZE: 1446 x 785 x 1100 mm
AGE RANGE: UP TO 8 YEARS
WEIGHT OF HEAVIEST PART 25 Kg
OVERALL WEIGHT OF UNIT 93 Kg
TROPICA - Double Arch Bridge 90110 page 1 of 3
Fixing Detail to Tower: 1. Attach Double Arch Bridge To Tower
using M10 x 50 lg Pent button head screws (B).
-
TROPICA - Oriental roof 90123 page 2 of 3
TROPICA - Double Arch Bridge 90110 page 2 of 3
MINIMUM SPACE
FOUNDATION DETAIL:
Fixing Detail 1. Logs are attached to chequer plate floor,
using (E) M10 x 25 lg Pent button head screw, Neoprene Washer (F) and (D) M10 Safety fastener.
FIXING DETAIL FOR LOGS
-
REF QTY DESCRIPTION PART No
A 1 Double Arch Bridge Assembly 90110-01
B 8 M10 x 50 lg Pent button head screw 2176-129
C 7 Plastic log 90110-02
D 21 M10 Safety Fastener 2177-002
E 21 M10 x 25 lg Pent button head screw 2176-126
F 21 Neoprene Washer 2900-041
COMPILED: APPROVED : REV NEW 1 2 3
MH ECN 1396 1455 minor minor
DATE: DATE: SIG. MH SB PK SB
31/010/01 DATE. 31/10/01 23/09/03 18/03/04 18/05/05
Note:-All spare parts are available from Wicksteed Leisure on request.
For maintenance instructions see separate sheet.
TROPICA - Double Arch Bridge 90110 page 3 of 3
Note:-Ensure all installation aids are removed before first use.
-
SPECIFICATION Barrier: Made from 20 mm Nominal Bore Tube, medium gauge to BS 1387, infills are 16Ø mm mild steel bar. Fasteners: Non standard anti-vandal, plated for weather protection. Finish: Low Lead Polyester powder paint to BS EN71 Pt. 3. Welds: Copper free wire diameter 1 mm conforming to 2091 AIB for Mild Steel.
INSTALLATION INSTRUCTIONS 1 Read installation instructions through before commencing erection of unit. 2 Do NOT tighten fastenings until the unit is completely assembled
DELIVERY LIST
Part No. Description Qty
90122-01 Metal Barrier Assembly 1
- Fixings Pack 1
TROPICA METAL BARRIER
PROD CODE: 90122
SIZE: 788 x 28 x 910 mm
AGE RANGE: UP TO 8 YEARS
WEIGHT OF HEAVIEST PART 15 Kg
OVERALL WEIGHT OF UNIT 15 Kg
TROPICA-Metal barrier 90122 page 1 of 2
Fixing detail to tower: 1. Attach (A) Metal barrier to tower using (B)
M10 x 25 lg Pent button head screws and (C) M10 Wicksteed washers.
-
REF QTY DESCRIPTION PART No
A 1 Metal Barrier assembly 90122-01
B 4 M10 x 25 lg Pent button head screws 2176-126
C 4 Wicksteed Washer 2215-519
COMPILED: APPROVED : REV NEW
MH ECN 1396
DATE: DATE: SIG. MH
2/11/01 DATE. 2/11/01
For maintenance instructions see separate sheet.
Note:-All spare parts are available from Wicksteed Leisure on request.
TROPICA-Metal barrier 90122 page 2 of 2
Note:-Ensure all installation aids are removed before first use.
Note: M8 bolts to be torqued to 18 Nm (13lbft.). M10 bolts to be torqued to 34 Nm (25lbft) M12 bolts to be torqued to 55 Nm (40lbft). All protruding screw threads to be peened over to remove sharp edges.
-
SPECIFICATION
INSTALLATION INSTRUCTIONS
Note
Note
PROD. CODE
SIZE
AGE RANGE
F/ FALL HEIGHT
HEAVIEST PART
TOTAL WEIGHT
Planet Jungle
Single Towers90150/90151/90152
0.8 x 0.8 x 3.25
990mm
Approx 70 - 78 kg ea
90150/1/2Page 1 of 3
90150SquareTower
90151QuadrantTower
90152OpenTower
Solid steel to BS 970 part 1Steel RHS to BS 4848 part 23mm Durbar chequer plateWelds are from copper-free wire to BS EN 440Low lead polyester powder paint to BS 71 part 3
1 Read instructions thoroughly before commencing installation of unit
2 Excavate foundations as shown in the foundation plan
3 Position tower in the excavated foundations on a brick, ensuring it is plumb,square and at the correct height, orientation and distance
4 When unit is fully assembled and all fixings secure, back fill the foundationswith concrete (4 parts gravel/2 parts sand/1 part cement) 0.095m² for towerswith 3 legs, 0.125m² for towers with 4 legs
5 Allow concrete to set for 48 hours before first use
ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE
-
90150/1/2
Page 2 of 3
1295
deck
heig
ht
220
8
3248
324
8
2898324
8
2898
90150SquareTower
90151QuadrantTower
90152OpenTower
800800
800
800
-
REV
ECN
SIG.
DATE:
COMPILED
DATE:
90150/1/2
Page 3 of 3
AB
23/04/12
3 LEG TOWER - FOR BARK FIX ADD
DESCRIPTIONPART NUMBERQTYITEM
BELOW GROUND ASSY5071-00331
SPRAGGING IRON3031-01032
M12 x 25 LG HEX HD SCREW2175-13463
4 LEG TOWER - FOR BARK FIX ADD
DESCRIPTIONPART NUMBERQTYITEM
BELOW GROUND ASSY5071-00341
SPRAGGING IRON3031-01042
M12 x 25 LG HEX HD SCREW2175-13483
FoundationsCare must be taken in abnormal conditions
750
750
750
750
300 square
300 square
380
Brick
400
305
38
0
Round offconcrete
Bark
Brick
123
Typical foundation detailsfor all single towers
01655AB
23/04/12
990
de
ckheig
ht
1
Minor
DB
30/10/13
-
SPECIFICATION
INSTALLATION INSTRUCTIONS
Note
Note
PROD. CODE
SIZE
AGE RANGE
F/ FALL HEIGHT
HEAVIEST PART
TOTAL WEIGHT
Planet Jungle
Double Tower90153
0.8 x 1.6 x 3.25
990mm
Approx 66.5 kg
Approx 129 kg
90153Page 1 of 4
Solid steel to BS 970 part 1Steel RHS to BS 4848 part 23mm Durbar chequer plateWelds are from copper-free wire to BS EN 440Low lead polyester powder paint to BS 71 part 3
1 Read instructions thoroughly before commencing installation of unit
2 Excavate foundations as shown in the foundation plan
3 Position tower in the excavated foundations on a brick, ensuring it is plumb,square and at the correct height, orientation and distance
4 Fix the towers together as shown
5 When unit is fully assembled and all fixings secure, back fill the foundationswith 0.155m² concrete (4 parts gravel/2 parts sand/1 part cement)
6 Allow concrete to set for 48 hours before first use
ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE
-
90153
Page 2 of 4
FoundationsCare must be taken in abnormal conditions
750
750750
300 square995
deck
heig
ht
38
0
Brick
40
0
305
380
Round offconcrete
Bark
8910
-
A ( 1 : 5 )
B ( 1 : 5 )Note - quarter deck not shown
C ( 1 : 5 )
90153
Page 3 of 4
A
B
C
354
4 7 3
6
-
REV
ECN
SIG.
DATE:
COMPILED
DATE:
90153
Page 4 of 4
AB
23/04/12
PARTS LIST
DESCRIPTIONPART NUMBERQTYITEM
DOUBLE TOWER B90153-0211
DOUBLE TOWER A90153-0112
Black Poepplemann Cup2611-031_Cup33
Black Poepplemann Cap2611-031_Cap34
M10 x 70 HEX HEAD BOLT2185-04215
M10 x 65 Hex Head Bolt2185-04126
M10 x 50 Hex Head Bolt2185-03827
FOR BARK FIX ADD
DESCRIPTIONPART NUMBERQTYITEM
BELOW GROUND ASSY5071-00358
SPRAGGING IRON3031-01059
M12 x 25 LG HEX HD SCREW2175-1341010
01655AB
23/04/12
1
Minor
DB
30/10/13
-
SPECIFICATION
INSTALLATION INSTRUCTIONS
Note
Note
PROD. CODE
SIZE
AGE RANGE
F/ FALL HEIGHT
HEAVIEST PART
TOTAL WEIGHT
Planet JungleCurved Climbing Wall
90154
1.09 x 0.24 x 1.89
6 to Adult
1.01m
Approx 22.5 kg
Approx 23.5 kg
90154Page 1 of 2
15mm thick HDPE 100% recyclableStandard fixings are made to either BS 3692 or BS 4190Non-standard fixings are anti-vandal and corrosion resistant
1 Read instructions thoroughly before commencing installation of unit
The climbing wall is overbent
2 To fit the panel position it against the tower and gently push in the centre,easing the panel over the struts and uprights as necessary
3 Fit the fixings down the middle of the panel
4 Fit the fixings down both sides
ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE
-
A ( 1 : 5 )
REV
ECN
SIG.
DATE:
COMPILED
DATE:
90154
Page 2 of 2
AB
24/04/12
PARTS LIST
DESCRIPTIONPART NUMBERQTYITEM
CURVED CLIMBING PANEL90154-0111
FIXING WASHER2900-041162
Black Poepplemann Cup2611-031_Cup323
Black Poepplemann Cap2611-031_Cap324
FIXING SPACER (15 panel)2472-009165
Wicksteed Washer2215-519166
M10 Binx Nut2191-010167
M10 x 50 Hex Head Bolt2185-038168
A
6 3 7 4
5
24 8 3
1
These fixings to goagainst inside oftower strut
01655AB
24/04/12
11672AB
03/12/12
-
SPECIFICATION
INSTALLATION INSTRUCTIONS
Note
Note
PROD. CODE
SIZE
AGE RANGE
F/ FALL HEIGHT
HEAVIEST PART
TOTAL WEIGHT
Planet Jungle
Monkey Pole Slider90156
0.8 x 0.45 x 2.37
Up to 8 years old
990mm
Aprox 25.25 kg
Approx 25.5 kg
90156Page 1 of 3
Solid steel to BS 970 part 1Steel nominal bore tube (medium) to BS 1387Welds are from copper-free wire to BS EN 440Low lead polyester powder paint to BS 71 part 3
Standard fixings are made toBS 3692 or BS 4190Non-standard fixings are anti-vandaland corrosion resistant
1 Read instructions thoroughly before commencing installation of unit
2 Excavate foundations as shown in the plan
3 Position pole slider on a brick in the excavated hole, ensuring it is plumb, squareand at the correct height
4 Fix the pole slider to the tower as shown
5 When the unit is fully assembled and all fixings secure, backfill the foundationwith 0.03m³ of concrete (4 parts gravel/2 parts sand/1 part cement)
6 Allow concrete to set for 48 hours before first use
ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE
-
90156
Page 2 of 3
FoundationsCare must be taken in abnormal conditions
375
375
445
300 square
375
Brick
40
0
300
380
Round offconcrete
Bark
Brick
456
-
REV
ECN
SIG.
DATE:
COMPILED
DATE:
90156
Page 3 of 3
AB
24/04/12
PARTS LIST
DESCRIPTIONPART NUMBERQTYITEM
WELDED MONKEY POLE SLIDER90156-0211
Wicksteed Washer2215-51942
M10 x 25 Pent Button Head2176-12643
Sliding Pole Assy4202-48115
M10 x 40 Pent Button Head2176-13316
M10 Safety Fastener2177-00217
FOR BARK FIX ADD
DESCRIPTIONPART NUMBERQTYITEM
BELOW GROUND ASSY5071-00314
SPRAGGING IRON3031-01015
M12 x 25 LG HEX HD SCREW2175-13426
2
3
1
Fixingsintotower
01655AB
24/04/12
11707AB
25/11/14
2
Minor
DB
21/08/15
-
SPECIFICATION
INSTALLATION INSTRUCTIONS
Note
Note
PROD. CODE
SIZE
AGE RANGE
F/ FALL HEIGHT
HEAVIEST PART
TOTAL WEIGHT
Planet JungleRamp c/w handrails & panels
90165
0.8 x 3 x 1.05
Up to 8 years old
990mm
Approx 57 kg
Approx 155 kg
90165Page 1 of 5
Solid steel components to BS 970 part 1Nominal bore tube (medium) to BS 1387RHS to BS 4848 part 23mm Durbar chequer plate15mm HD polyethylene 100% recyclableand non-toxic
Logs made from dia 72mm half round recycledplasticStandard fixings are to BS 3692 or BS 4190Non-standard fixings are anti-vandal andcorrosion resistantWelds are from copper-free wire to BS EN 440Low lead polyester powder paint to BS 71
1 Read instructions thoroughly before commencing installation of unit
2 Excavate foundations as shown
3 Position ramp on bricks in foundations and fix to tower as shown
4 Fix handrails to ramp and tower as shown
5 Fit panels to handrails as shown
6 When unit is fully assembled and all fixings secure, backfill foundations with0.13m³ of concrete (4 parts gravel/2 parts sand/1 part cement)
7 Allow concrete to set for 48 hours before first use
ENSURE ALL INSTALLATION AIDS ARE REMOVED BEFORE FIRST USE
-
90165
Page 2 of 5
FoundationsCare must be taken in abnormal conditions
1993
600
300
375
Bricks
400
300
38
0
BarkRound offconcrete
18
19
20Brick
-
90165
Page 3 of 5
16
10
15
10
15
10
14
11
10
13
1
2
4
3
5
5
Panels to handrails and handrailsto ramp fixing detail
7
-
90165
Page 4 of 5
9
17
9
17
8
6
12
17
Log fixingdetail
Ramp and handrailfixing to tower
-
REV
ECN
SIG.
DATE:
COMPILED
DATE:
90165
Page 5 of 5
AB
25/04/12
FOR BARK FIX ADD
DESCRIPTIONPART NUMBERQTYITEM
BELOW GROUND ASSY5071-003218
SPRAGGING IRON3031-010219
M12 x 25 LG HEX HD SCREW2175-134420
PARTS LIST
DESCRIPTIONPART NUMBERQTYITEM
BOTTOM LH INFILL PANEL90165-0411
TOP LH INFILL PANEL90165-0312
BOTTOM RH INFILL PANEL90165-0213
TOP RH INFILL PANEL90165-0114
HAND RAIL ASSY90139-0225
PLASTIC LOG90110-02106
LOG RAMP WELDED ASSY90103-0217
FIXING WASHER2900-041308
Wicksteed Washer2215-51949
M10 Washer2215-5083010
M8 Washer2215-5072411
M10 Safety Fastener2177-0023012
M8 Safety Fastener2177-0012413
M8 x 16 Pent Button Head2176-1512414
M10 x 30 Pent Button Head2176-132415
M10 x 50 Pent Button Head2176-129216
M10 x 25 Pent Button Head2176-1263417
01655AB
25/04/1207/10/14MC
Minor
1
-
Product: Date of Issue: 27/04/12
Issue:
Item Unit Qty Part No. Checked
1 1 90105-02
2 1 90105-01
3 2 4013-038
4 17 90110-02
5 1 90110-01
6 1 90122-01
7 1 90151-01
8 1 90153-02
9 1 90153-01
10 2 90154-01
11 1 90156-02
12 1 4202-481
13 1 90165-04
14 1 Top LH infill panel 90165-03
15 1 Bottom RH infill panel 90165-02
16 1 Top RH infill panel 90165-01
17 2 Hand rail assy 90139-02
18 1 Log ramp welded assy 90103-02
19 2 Pedestal support leg - middle 4013-037
1 Fixing pack
Picked By: Checked By:
COMPILED REV 0 1 2 3 4BY: AB ECN No. 1655 1663 1672 1707 Minor
DATE 27/04/2012 12/09/2012 03/12/2012 12/12/2014 24/08/2015
DATE: 27/04/12 SIGN AB AB AB AB DB
Sheet 1 of 1
Curved climbing panel *
Welded quadrant tower assy
DESPATCH LIST
Plastic log *
Metal barrier
Wide slide chute
Description
901-KIFA Kifaru
Double tower A
Total No. of Items
Sliding Pole Assy
Bottom LH infill panel
Welded monkey pole slider
Order No:
Double width slide barrier
Pedestal support leg - runout
Double tower B
Items marked * to be fitted prior to despatch
Double arch bridge welded assy
-
Product: Date of Issue: 27/04/12
Issue:
Item Unit Qty Part No. Checked
1 4 3031-010
2 2 2611-005
3 6 2215-519
4 32 2571-013
5 2 2176-129
6 16 2176-176
7 2 2177-002
8 4 2176-126
9 2 2215-509
10 21 Fixing washer * 2900-041
11 21 M10 safety fastener * 2177-002
12 8 M10 x 50 pent button head screw 2176-129
13 21 M10 x 25 pent button head screw * 2176-126
14 4 2215-519
15 4 2176-126
16 3 2611-031
17 3 2611-031
18 1 2185-042
Picked By: Checked By:
COMPILED REV 0 1 2 3 4 5BY: AB ECN No. 1655 1663 1672 Minor Minor Minor
DATE 27/04/2012 12/09/2012 03/12/2012 23/09/2013 30/10/2013 13/03/2014DATE: 27/04/12 SIGN AB AB AB MC DB DB
REV 6 7
ECN No. Minor Minor
DATE 07/10/2014 24/08/2015
SIGN MC DB
Order No:
Wicksteed washer
90105 Wide Slide
M10 x 50 Pent Button Head
M12 x 25 pent button head screw
End plug (1¼NB)
Description
90122 Metal barrier
Spragging iron
Sheet 1 of 3
M10 Safety Fastener
FIXINGS LIST
M12 fibre washer
M10 x 25 pent button head screw
M12 Plain Washer
Wicksteed washer
M10 x 25 pent button head screw
901-KIFA Kifaru
90110 Double Arch Bridge
Total No. of Items
Black Poepplemann cup
Black Poepplemann cap
M10 x 70 hex head bolt
Items marked * to be fitted before despatch
90153 Double Tower
-
Product: Date of Issue: 27/04/12
Issue:
Item Unit Qty Part No. Checked
19 2 2185-041
20 2 2185-038
21 32 2900-041
22 64 2611-031
23 64 2611-031
24 32 2472-009
25 32 2215-519
26 32 2191-010
27 32 2185-038
28 4 2215-519
29 4 2176-126
30 1 2176-133
31 1 2177-002
32 30 2900-041
33 4 Wicksteed washer 2215-519
34 30 M10 washer * 2215-508
35 24 M8 washer 2215-507
Picked By: Checked By:
COMPILED REV 0 1 2 3 4 5BY: AB ECN No. 1655 1663 1672 Minor Minor Minor
DATE 27/04/2012 12/09/2012 03/12/2012 23/09/2013 30/10/2013 13/03/2014DATE: 27/04/12 SIGN AB AB AB MC DB DB
REV 6 7
ECN No. Minor Minor
DATE 07/10/2014 24/08/2015
SIGN MC DB
Items marked * to be fitted before despatch
Total No. of Items
90165 Ramp c/w Handrails & Panels
Fixing washer *
90156 Monkey Pole Slider
Wicksteed washer
M10 x 25 pent button head screw
M10 x 40mm Pent Button Head
M10 Safety Fastener
Black Poepplemann cup *
Black Poepplemann cap *
Fixing spacer (15 panel) *
Wicksteed washer *
M10 binx nut *
M10 x 50 hex head bolt *
90153 Double Tower (cont)
M10 x 65 hex head bolt
M10 x 50 hex head bolt
90154 Curved Climbing Wall
Fixing washer *
FIXINGS LIST Sheet 2 of 3
901-KIFA Kifaru
Order No:
Description
-
Product: Date of Issue: 27/04/12
Issue:
Item Unit Qty Part No. Checked
36 30 2177-002
37 24 2177-001
38 24 M8 x 16 pent button head screw 2176-151
39 4 2176-132
40 2 M10 x 50 pent button head screw 2176-129
41 34 M10 x 25 pent button head screw (30 off *) 2176-126
42 20 Insert plug M10 2611-016
43 2 M8 pent key 2372-003
44 2 M10/M12 pent key 2372-007
Picked By: Checked By:
COMPILED REV 0 1 2 3 4 5BY: AB ECN No. 1655 1663 1672 Minor Minor Minor
DATE 27/04/2012 12/09/2012 03/12/2012 23/09/2013 30/10/2013 13/03/2014DATE: 27/04/12 SIGN AB AB AB MC DB DB
REV 6 7
ECN No. Minor Minor
DATE 07/10/2014 24/08/2015
SIGN MC DB
Items marked * to be fitted before despatch
Total No. of Items
FIXINGS LIST Sheet 3 of 3
901-KIFA Kifaru
Order No:
Description
90165 Ramp c/w Handrails & Panels (cont)
M8 safety fastener
M10 x 30 pent button head screw
M10 safety fastener *