877.566.3837 • - Meter, Valve And Controlmetervalveandcontrol.com/pdf/36035 MVNC Catalog.pdfAbout...
Transcript of 877.566.3837 • - Meter, Valve And Controlmetervalveandcontrol.com/pdf/36035 MVNC Catalog.pdfAbout...
877.566.38372
About Us
Meter, Valve and Control was founded in 2004 to provide exceptional process measurement and control products in the Western US. Our core product lines are gas meters, gas regulators, gas safety equipment, gas electronics, and water meters. Meter, Valve and Control serves both the utility and non-utility markets (commercial/industrial/submetering).
We aim to provide high quality, dependable measurement and control solutions to our customer base. Meter, Valve and Control is run by a team of highly experienced professionals with a focus on excellent customer service and quick delivery.
Karen HenrichPresident
Scott HenrichVice President
www.mvandc.com 3
Product Application Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Gas Regulator - Sizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Selecting The Proper Gas Regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6Gas Regulators - Itron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7Gas Regulators - Itron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8Sizing Table - Itron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9Ventless Regulators - Pietro Fiorentini . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10Sizing Table 2# / 5# - Pietro Fiorentini . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11Gas Regulator Cross Reference - Line Service . . . . . . . . . . . . . . . . . . . . . . . . . . . .12Industrial/Utility/Transmission - Pietro Fiorentini . . . . . . . . . . . . . . . . . . . . . . . . . . .13Industrial/Utility/Transmission - Pietro Fiorentini . . . . . . . . . . . . . . . . . . . . . . . . . . .14Gas Regulators - Marsh Bellofram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15Gas Regulators - Marsh Bellofram. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Gas Meters - Diaphragm and Turbine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17Rotary Meters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18Ultrasonic & Thermal Mass Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19Gas Meter Sizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20Gas Strainers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21Gas Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22Gas Control/Electronics - Eagle Research. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23Gas Accessories - IMAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24Earthquake Valves - PSP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25Earthquake Valves - Little Fire Fighter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Propane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27Water Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28Water Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29Submetering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30Products/Manufacturers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Contents
How to size a Regulator
Information Requested1. Inlet Pressure – Typically PSIG but may
be "wc2. Outlet Pressure – Typically in inches of water
column ("wc) but may be in PSIG3. Maximum Expected Gas Load or
Capacity – Typically BTU(H), (S)CFH, MBH, CCF
4. Pipe Size – Regulators are available in ½" through 10" sizes.
5. Gas Type – Typically natural gas but may be other gas like propane (LPG).
6. Indoor or Outdoor – If indoors you will likely want to consider regulators with vent limiters (line service regulators) to eliminate the need to run costly vent piping which is required on standard regulators with vents. If outdoors you can use either a service regulator or a painted line service regulator with vent limiter removed.
7. Optional Features – Overpressure protection such as internal relief, worker monitor, internal monitor, in-line monitor, overpressure shutoff, under pressure shutoff, silencers, etc.
Sizing1. Call us at 877-566-3837 and we will size for
you.2. Use sizing software found at https://www.
itron.com/na/productsandservices/pages/reg-ulator-sizing-application.aspx or http://www.Fiorentiniminireg.It/fiogovernorsus/
3. Use sizing tables on our website or in your catalog
Service RegulatorsStandard domestic springoperated regulator(most common) B42R-B31R-1/2 to 1-1/4"
Standard mobile home park gasregulator with 90 degreevalve body (B42R-3/4-90)
Standard spring operatedcommercial regulatorB34SR – 1-1/4 to 3"
Standard spring operatedindustrial regulatorB34 & B38R – 1-1/4 to 3"
Pilot operated regulatorfor fixed factormeasurement applicationsCL31-CL231-CL34-CL38-CL8383/4-3"
Spring operated highcapacity high pressureoutlet industrialregulatorRB1700-RB4000 1-1/2 to 3"
Line Service Regulators
Line service regulators made by Pietro Fiorentini are available in pipe sizes ½" through 4". All sizes can come with vent limiters installed (indoor applications) or with a vent cap (outdoor applications).These regulators are CSA/ANSI certified unlike most service regulators.
For 2 psig and 5 psig inlet pressures see quick sizing charts located on pages 9
and 11.
www.mvandc.com 5
Gas Regulator - SizingProduct Application Guide
877.566.38376
Gather Information • Inlet Pressure - psig • Outlet Pressure – “wc • Max Load – cfh/btuh/mbh • Pipe Size – “ • Indoor or Outdoor • Special Certs – CSA/AGA
Indoor Applications Governor Line Service Regulator best or Service Regulator with vent pipe
CSA/ANSI Z21.80 Spec
Governor Line Service Regulator – Governor series typically have higher capacities than service types.
Outdoor Application Service Regulator or Line Service Regulator with vent limiter removed.
Inlet Pressure > 5 psig Service Regulator
High Capacity Application
Governor Line Service
Pipe Size > 2” Governor Line Service Regulator for 3 and 4” or Itron 3
Wide Flow Range
Governor Line Service Regulator – Applications serving multiple appliances with variable flow rates can be an issue with service regulators.
Quick on/off Application Governor Line Service Regulator - Some applications go from high fire to off which require a fast acting line service regulator.
Regulator Types Defined Service Regulator – Commonly Itron B42R/B34SR/B34R or American 1813C/1803/1813. Requires vent pipe for indoor applications. Line Service Regulator – Pietro Fiorentini Governor Series RG-30___. Utilizes vent limiters to eliminate vent pipe on indoor applications.
AGA/ANSI B109.4 Spec Service Regulator
PAGE #
PAGE #
PAGE #
PAGE #
PAGE #
PAGE #
PAGE #
PAGE #
PAGE #
”
Selecting The Proper Gas Regulator
Page 7
Page 10
Page 7
Page 10
Page 10
Page 10
Page 10
Page 7
Page 10
www.mvandc.com 7
Gas Regulators - Itron
R - Internal Relief, N - No Internal Relief, HP - High PressureIMN - Internal Monitor, IMR - Internal Monitor with Relief, IMRV - IMR with Early Warning VentM - Monitor, D - Downstream Control Tap
Service and Industrial Appliance Regulators
877.566.38378
Gas Regulators - Itron
Constant-Loaded (Fixed Factor Billing) Regulators
CL31 Pilots: R,N
Options: IM, IMV
1 to 20 PSIG 3/4, 1, 1-1/4 NPT 125 PSIG 4,000
CL231 Pilots: R, N 1 to 20 PSIG 1-1/4, 1-1/2, 2 NPT
2, 3 FL 125 PSIG 7,500
CL34 Pilots: 1, 2
Options: M, IM, D
5-inch w.c. to 60 PSIG 1-1/4, 1-1/2, 2 NPT
2, 3 FL 150 PSIG 40,000
CL38 Pilots: 1, 2
Options: M, IM, IMV, D
5-inch w.c. to 30 PSIG 1-1/2, 2 NPT
2, 3 FL 150 PSIG 60,000
CL838 Pilots: 1, 2
Options: M, IM, IMV, D
5-inch w.c. to 30 PSIG 2 x 2 NPT
2 x 3, 2 x 4 FL 150 PSIG 100,000
High Pressure (Field Cut) Regulators
B36 R, N 1 PSIG to 60 PSIG 3/4, 1, 1-1/4 175 PSIG 10,000
B56 R, N 5 PSIG to 60 PSIG 1/2, 3/4, 1, 1-1/4 1000 PSIG 23,000
B35 R, N, M 5 to 150 PSIG 3/4, 1 NPT 1000 PSIG 20,000
Internal Monitor (IM) Principle of Operation
Standard regulator and upstream monitor orifice Standard regulator failed. Upstream monitor orifice control
Standard regulator orifice failed - upstream monitor orifice in No Flow.
V option. Vent small volume to atmosphere. Re-places tell-tale relief valve.
Constant-Loaded (Fixed Factor Billing) Regulators
CL31 Pilots: R,N
Options: IM, IMV
1 to 20 PSIG 3/4, 1, 1-1/4 NPT 125 PSIG 4,000
CL231 Pilots: R, N 1 to 20 PSIG 1-1/4, 1-1/2, 2 NPT
2, 3 FL 125 PSIG 7,500
CL34 Pilots: 1, 2
Options: M, IM, D
5-inch w.c. to 60 PSIG 1-1/4, 1-1/2, 2 NPT
2, 3 FL 150 PSIG 40,000
CL38 Pilots: 1, 2
Options: M, IM, IMV, D
5-inch w.c. to 30 PSIG 1-1/2, 2 NPT
2, 3 FL 150 PSIG 60,000
CL838 Pilots: 1, 2
Options: M, IM, IMV, D
5-inch w.c. to 30 PSIG 2 x 2 NPT
2 x 3, 2 x 4 FL 150 PSIG 100,000
High Pressure (Field Cut) Regulators
B36 R, N 1 PSIG to 60 PSIG 3/4, 1, 1-1/4 175 PSIG 10,000
B56 R, N 5 PSIG to 60 PSIG 1/2, 3/4, 1, 1-1/4 1000 PSIG 23,000
B35 R, N, M 5 to 150 PSIG 3/4, 1 NPT 1000 PSIG 20,000
Internal Monitor (IM) Principle of Operation
www.mvandc.com 9
Sizing Table - Itron
Itron Service Regulators
Quick Regulator Selection Chart
Itron Max Capacity (CFH) for 5 PSIG Inlet, 7"WC Outlet
Model Pipe Sizes
# 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 3" 4"
B42R 300 830 1,230 1,300
B57R/B58R 650 1,110 2,020
B31R 620 1,750 1,900
B531 600 1,250 1,500 2,000 3,150
B34SR 2,078 3,869 5,150 5,150
B34R 2,532 2,900 8,000 8,000
B38R 3,292 10,800 10,800
B838 11,500 18,900
CL34-1 2,500 7,500 10,000 10,000
CL38-1 7,500 13,500 13,500
RB1710 15,000
RB4010 38,000
Itron Service Regulators
Quick Regulator Selection Chart - 60# Inlet Control
Itron Max Capacity/ Orifice Size (CFH) for 5-60 PSIG Inlet, 7"WC Outlet
Model Pipe Sizes
# 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 3" MAX ORIFICE
B42R 200 500 500 600 1/4"
B57R/B58R 485 1,050 1,500 3/16X1/4"
B31R 700 1,090 1,550 3/8"
B531 400 950 1,200 1,700 2,280 3/8"
B34SR 350 800 1,120 1,120 1/4X3/8"
B34R 3,500 3,750 7,500 7,500 7/8"
B38R 4,000 8,000 8,000 1"
B838 6,100 10,200 3/4"
CL34-1 1,500 3,075 4,100 4,100 1/2"
CL38-1 9,225 12,300 12,300 1-1/4"
RB1710 15,000 1-1/8"
Itron Service Regulators
Quick Regulator Selection Chart
Itron Max Capacity (CFH) for 2 PSIG Inlet, 7"WC Outlet
Model Pipe Sizes
# 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 3" 4"
B42R 300 495 700 960
B57R/B58R 535 780 1,300
B31R 560 1,120 1,150
B531 600 830 960 1,250 2,040
B34SR 1,530 1,950 2,300 2,500
B34R 1,820 2,242 4,700 5,500
B38R 2,785 5,850 6,125
B838 6,400 8,450 10,300
CL34-1 2,500 4,570 6,100 7,000
CL38-1 6,500 8,400 9,000
RB1710 9,000
RB4010 18,000
Pietro Fiorentini’s Governor line of gas regulators are designed to comply with the latest CSA and international standards for regulators suitable for indoor and outdoor installations. The governor family of regulators is ideal for a wide range of residential through large industrial applications. Governors are best known for their ease of installation, especially in indoor applications where no vent pipe is required.
Application: Ventless, Residential & CommercialCapacity Range: 0 - 40,000 SCFHOutlet Pressures 2.5" WC. to 4 PSIGMax Inlet Pressure Rating: 7 PSIGConnection Size(s): 1/2" to 4"
Standard ModelInlet Pressure Range: 3" W.C. to 2 PSIG
Overpressure Device (OPD) ModelInlet Pressure Range: 7" W.C. to 5 PSIG
Main Features -
• CSA 6.22a-2005 ANSI Z21.80A2005 Class I for outlet pressures up to 14"W.C. Certified
• Integral Vent Limiter
• External Vent Limiter – no vent line required*
• Positive dead-end lockup
• Inlet and Outlet test ports
• 500 to 1 Turndown (500:1)
• Minimum Δ P – 1"W.C.
Main Features -
• CSA Certified to ANSI Z21.80A2005
• CSA Certified 6.22a-2005 Class I for outlet pressures up to 14"W.C. and inlet pressure up to 5 PSIG
• Integral Vent Limiter
• External Vent Limiter – no vent line required*
• Positive dead-end lockup
• Inlet and Outlet test ports
• 500 to 1 Turndown (500:1)
877.566.383710
Ventless Regulators - Pietro Fiorentini
Line Service Regulators - Ventless
Pietro Ventless - 2 PSIG Inlet
Fiorentini Max Capacity (CFH) For 2 PSIG Inlet, 7"WC Outlet
Governor Pipe Sizes
Model 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 3" 4"
RG-30051-1/2"-EVL 928 RG-30150-HC-1/2"-EVL 2,205
RG-30052-3/4"-EVL 1,155 RG-30151-HC-3/4"-EVL 2,785
RG-30053-1"-EVL 1,501 RG-30152-HC-1"-EVL 3,308 RG-30153-1.25"-EVL 7,891 RG-30154-1.5"-EVL 8,240 RG-30155-2"-EVL 15,087
RG-31057F-3"-EVL 23,202 RG-30158F-4"-EVL 40,612
Line Service Regulators - Ventless
Pietro Ventless - 5 PSIG Inlet
Fiorentini Max Capacity (CFH) For 5 PSIG Inlet, 7"WC Outlet
Governor Pipe Sizes
Model 1/2" 3/4" 1" 1-1/4" 1-1/2" 2" 3" 4"
RG-30051DC-1/2"-EVL 928 RG-30150DC-HC-1/2"-EVL 2,205
RG-30052DC-3/4"-EVL 1,155 RG-30151DC-HC-3/4"-EVL 2,785
RG-30053DC-1"-EVL 1,501 RG-30152DC-HC-1"-EVL 3,308 RG-30153DC-1.25"-EVL 7,891 RG-30154DC-1.5"-EVL 8,240 RG-30155DC-2"-EVL 15,087
RG-30157FDC-3F-EVL 23,202 RG-30158FDC-4"-EVL 40,612
www.mvandc.com 11
Sizing Table 2#-5# - Pietro Fiorentini
Items in blue print are CSA/ANSI Z21.80 certified for up to 2 PSIG inlet pressureItems in red print are CSA/ANSI Z21.80 certified for up to 5 PSIG inlet pressureCapacities for PF apply to individual appliance or total load of all equipment downstream. Maxitrol capacities shown are for single appliance. Multiple appliances may allow slightly larger capacities.PF Governor Information • Certified for installation in any position. Maxitrol must be installed horizontal only. • Includes both internal and external vent limiter for added safety. • Includes two diaphragms for added safety. • Utilizes a true balanced valve design providing accurate outlet pressures with a 500 to 1 (500:1) turndown. • Provides complete bubble tight lock up in the absence of gas flow. • Inlet and outlet test ports are standard. • Requires a minimum of 1"W.C. differential to operate. • CSA certified outlet pressures up to 14"W.C. for 2 PSIG regulators and 1 PSIG outlet for 5 PSIG regulators. Outlet pressures of up to 4.26 PSIG can be achieved when CSA certification is not a requirement.
Pietro Itron/ Sensus Fiorentini (PF) Actaris/ Elster/ Invensys/ Governor Schlumberger American Fisher Equimeter/ Line Series Maxitrol Sprague Singer Model Rockwell Size Model # Model # Model # Model # # Model # Capacity Notes 3/8 325-3L-EVL 496 325-3L = 140 CFH 325-3L47-EVL RV20/RV47
1/2 RG-30051-1/2"-EVL 325-3L-EVL B42R 1213B 496 30051 CAPACITY = 928 CFH RG-30150-HC-1/2" -EVL 325-5AL-EVL 30150 = 2,205 CFH RG-30051DC-1/2"-EVL 325-3L47-EVL 325-5AL = 300 CFH RG-30150DC-HC-1/2"-EVL 32S-3L48-EVL 30051DC = 928 CFH 325-5AL48-EVL 30051DC-HC = 2,205 CFH RV47/RV48/RV52 325-5AL48 = 320 CFH
3/4 RG-30052-3/4" -EVL 325-5AL-EVL B42R 1213B HSR 496 30052 CAPACITY =1,155 CFH RG-30151-HC-3/4" -EVL 325-5AL48-EVL B57R 1813C CS200 143 30151 = 2,785 CFH RG-30052DC-3/4" -EVL 325-5AL600-EVL B58R SR100 325-5AL = 300 CFH RG-30151DC-HC-3/4" -EVL RV52/RV53 B31R CR4000 30052DC = 1,115 CFH 30151DC-HC = 2,785 CFH 325-5AL48 = 320 CFH
1 RG-30053-1"-EVL 325-5AL-EVL B42R 1213B HSR 496 30053 CAPACITY =1,501 CFH RG-30152-HC-1"-EVL 325-5AL-600-EVL B57R 1813C CS200 143 30152 = 3,308 CFH RG-30053DC-1" -EVL RV53/RV61 B58R SR100 325-5AL = 300 CFH RG-30152DC-HC-1" -EVL 210D B31R CR4000 30053DC = 1,501 CFH 30152DC-HC = 3,308 CFH 325-5AL600 = 425 CFH
1-1/4 RG-30153-1.25"-EVL 325-7AL-EVL B42R 1813C CS200 143 30153 CAPACITY = 7,891 CFH RG-30153DC-1.25"-EVL 325-7AL-210D-EVL B57R 3000 CS400 243-8 325-7AL = 1,250 CFH RV61/RV81 B58R S201 243-12 30053DC = 7,891 CFH 210D B31R 325-7AL-210D = 1,250 CFH B34SR B34R
1-1/2 RG-30154-1.5"-EVL 325-7AL-EVL B34SR 1813 CS400 243-8 30154 CAPACITY = 8,240 CFH RG-30154DC-1.5" -EVL 325-7AL-210D-EVL B34R 3000 S201 243-12 325-7AL= 1,250 CFH RV81 B38R 30154DC = 8,240 CFH 210D/210E RB1700 325-7AL-210D = 1,250 CFH
2 RG-30155-2" -EVL RV91 B34SR 1813 CS400 243-8 30155 CAPACITY = 15,087 CFH RG-30155DC-2"-EVL 210E B34R 3000 S201 243-12 30155DC = 15,087 CFH B38R 441
3 RG-31057F-3"-EVL RV111 B34SR 3000 121 30157 CAPACITY = 23,202 CFH RG-30157FDC-3F-EVL 210G B34R 441 30157DC = 23,202 CFH B38R
4 RG-30158F-4"-EVL RV131 RB4000 3000 121 30158 CAPACITY = 40,612 CFH RG-30158FDC-4"-EVL 210J 441 30158DC = 40,612 CFH
877.566.383712
Gas Regulator Cross Reference - Line Service
Pietro Fiorentini offers a complete line of high quality regulators that can beused in Industrial, Commercial, Transmission and Distribution applications. All of theseregulators have extremely high turndown rates, wide outlet pressure ranges, and cover low to high inlet pressure ratings. PF regulators are direct acting or pilotoperated gas pressure regulators with integral options for slam shut valves, inlinemonitors, silencers, and remote operations built right in.
Industrial & Commercial (1" to 8")
Transmission & Distribution (1" to 10")
Safety Valves: Relief, Slam-Shut & Controllers (1" to 8")
www.mvandc.com 13
Industrial/Utility/Transmission - Pietro Fiorentini
877.566.383714
Industrial/Utility/Transmission - Pietro Fiorentini
Max Outlet Minimum
Size Inlet Pressure Pressure Regulator Body Regulator Connection
Model (inches) Pressure Range Differential Operation Material Turndown Type
Industrial & Commercial - Direct Acting Regulators
Dival 5001"x1" or 1"x1.5" 290 PSIG 4" WC to 30 PSIG
6" WC (MP Head) / 4.4
PSI (TR Head) Direct
Ductile Iron/Steel 500 to 1
150 RF or Threaded
Dival 600 1", 1.5", 2" 290 PSIG 4" WC to 60.9 PSIG
5" WC (BP)1.2 PSIG (MP)4.3 PSIG (TR) Direct
Ductile Iron/Steel 500 to 1
ANSI 150RF or ANSI 125FF
Norval (1"-3") 1", 2", 3" 232 PSIG 3" WC to 65 PSIG 1 PSIG DirectDuctile
Iron/Steel 500 to 1
ANSI 150/300/600
RF or RTJ
Norval (4"-8") 4", 6", 8" 165 PSIG 5" WC to 65 PSIG 1 PSIG DirectDuctile
Iron/Steel 500 to 1
ANSI 150/300/600
RF or RTJ
Transmission and Distribution (1" to 10") - Pilot Operated Regulators
Reval 182
1", 2", 3", 4",
6", 8" 10" 275 PSIG 3" WC to 174 PSIG 1.45 PSIG Pilot
Ductile Iron/Cast
Steel 1,000 to 1ANSI 150RF
or RTJ
Aperval 101 2", 3", 4" 275 PSIG 2" WC to 130 PSIG 7 PSIG PilotDuctile
Iron 500 to 1 150 RF
Aperval1", 2", 3",
4" 275 PSIG 8" WC to 261 PSIG 7 PSIG Pilot
Ductile Iron/Cast
Steel 500 to 1ANSI 150RF
or RTJ
Aperflux 101 2", 3"1.232 PSIG 12 to 1,073 PSIG 15 PSIG Pilot Cast Steel 500 to 1
ANSI 300/600 RF or RTJ
Aperflux 851
1", 2", 3", 4", 6", 8",
10"1,232 PSIG 12 to 942 PSIG 7 PSIG Pilot Cast Steel 500 to 1
ANSI 300/600 RF or RTJ
Reflux 819
1", 2", 3", 4", 6", 8",
10"1,450 PSIG 4 to 1,073 PSIG 7.25 PSIG Pilot Cast Steel 1,000 to 1
ANSI 300/600 RF or RTJ
Reflux 819 FO
1", 2", 3", 4", 6", 8",
10"1,450 PSIG 14.5 to 1,073 PSIG 30 PSIG Pilot Cast Steel 1,000 to 1
ANSI 150/300/ 600 RF or RTJ
ATF 15 (Anti-freeze) 1"
3,190 PSIG 21.7 to 870 PSIG N/A Direct Steel High Threaded
Safety Valves: Relief, Slam-Shut and Controllers (1" to 8")
SBC 7821", 2", 3", 4", 6" & 8"
1,479 PSIG .29 to 1,305 PSIG Shutoff N/A
Overpressure Slam Shut Cast Steel N/A
ANSI 150/300/ 600 RF or RTJ
HBC 9754", 6", 8",
10"1,479 PSIG
145 to 1,232 PSIG Overpres-sure/ 58 to 1087 PSIG Under-
pressure N/A
Overpressure/ Underpressure
Slam Shut Cast Steel N/AANSI 300/600
RF OR RTJ
PVS 7821", 2", 3", 4", 6" & 8"
1,232 PSIG 20 to 1,102 PSIG Relief N/A
Relief Valve (Pilot)
Ductile Iron/Cast
Steel N/AANSI 150/300/
600 RF
FIO (Five In One)
Aperflux Aperval
Dixi Reflux Reval Terval
The Five In One allows for the user to remotely control pressure reduction stations of a natural gas distribu-tion network. The F.I.O. features five functions including indirect flow measurement, outlet pressure control,
flow limitation, remote monitoring and end user management.
www.mvandc.com 15
Max Outlet
Size Inlet Pressure Body
Model (inches) Pressure Range Operation Material Picture
T371/2", 3/4"
NPT400 PSIG 10 to 125 PSIG Direct Aluminum
T383/8", 1/2",
3/4", 1" NPT400 PSIG 10 to 125 PSIG Direct Zinc, Aluminum
T39 1/4" NPT 6,000 PSIG 10 to 500 PSIG DirectBrass, Stainless
Steel, Nickel Plated
T50 1/4" NPT 250 PSIG 10 to 120 PSIG Direct Aluminum
T79V3/8", 1/2",
3/4", 1" NPT400 PSIG 0 to 200 PSIG
Relay/ Volume Booster
Zinc, Aluminum
T95H1/2", 3/4", 1"
NPT300 PSIG
(Steel)15 to 150 PSIG Direct
Cast Itron, Steel, Stainless Steel
T98H 3/4", 1" NPT300 PSIG
(Steel)15 to 200 PSIG Direct Aluminum
T1193/4", 1",
1-1/4" NPT150 PSIG 3 TO 60 PSIG Control Valve
Cast Itron, WCB Steel
TF6273/4", 1", 2"
NPT250 PSIG 5 to 100 PSIG Pilot
Ductile Iron, WCB Steel, LCC
T52551/4", 1/2",
3/4", 1" NPT425 PSIG 3 to 150 PSIG Direct 316 Stainless Steel
T289 1", 2" NPT 100 PSIG 7" WC - 75 PSIGRelief Valve/ Back
Pressure1"-Aluminum, 2"-Cast Iron
T6273/4", 1", 2"
NPT2,000 PSIG 5 to 500 PSIG Direct
Cast Iron, Steel, LCC
T701/4", 3/8", 1/2" NPT
250 PSIG 0 to 200 PSIG Direct Aluminum
T1808 2" NPT 125 PSIG 3 to 125 PSIGRelief Valve/ Back
PressureCast Itron, WCB
Steel
Gas Regulators - Marsh Bellofram
Air/Process Gas Regulators
877.566.383716
Max Outlet
Size Inlet Pressure Body
Model (inches) Pressure Range Operation Material Picture
T600 3/4", 1" NPT 150 PSIG 4" WC to 7 PSIG Direct Cast Iron
T2001-1/4", 1-1/2",
2" NPT125 PSIG 2" WC to 10 PSIG Direct
Ductile Cast Iron, WCB Steel
T133 2" NPT 125 PSIG 2" WC to 10 PSIG DirectDuctile Cast Iron,
WCB Steel
T912Inlet - 1/4"
Outlet - 1/4", 3/8" NPT
250 PSIG 3" WC to 5 PSIG Direct Zinc
T1433/4", 1",
1-1/4" NPT125 PSIG 3.5" WC to 6 PSIG
Direct, Low-Pres-sure Cut-off
Cast Iron
T99 2" NPT 400 PSIG 7" WC to 100 PSIG Integrated Pilot Cast Iron, Steel
TL6273/4", 1", 2"
NPT250 PSIG 5 to 40 PSIG Direct
Ductile Cast Iron Body, Aluminum
Bonnet
T39 1/4" NPT 6,000 PSIG 10 to 500 PSIG DirectBrass/ Stainless
Steel
T627W3/4", 1", 2"
NPT900 PSIG 10 to 500 PSIG Direct
Ductile Iron, WCB Steel
T1808 2" NPT 125 PSIG 3 to 125 PSIGRelief Valve/
Back PressureCast Iron/ WCB
Steel
T98H 3/4", 1" NPT300 PSIG
(Steel)15 to 200 PSIG
Relief Valve/ Back Pressure
Cast Iron, Steel, Stainless Steel
T95H1/2", 3/4", 1"
NPT300 PSIG
(Steel)15 to 150 PSIG Direct
Cast Iron, Steel, Stainless Steel
T95H1/2", 3/4", 1"
NPT300 PSIG 15 to 150 PSIG Direct
Steel, Stainless Steel
T98H 3/4", 1" NPT 300 PSIG 15 to 200 PSIGRelief Valve/
Back PressureSteel, Stainless
Steel
Accessories
T800 In-Line Relief
1/4" NPT Ports
250 PSIG2 to 50 PSIG Relief Pressure
Set PointsRelief Valve Cast Iron
T350 Stainless or Aluminum Filter
1/4" NPT 4,000 PSIG1, 5, 25, and 50 Micron Glass
Microfiber/Stainless Mesh Filter
Stainless Steel, Aluminum
T1367 Instrument Supply Manifold
1/4" NPT 4,000 PSIG10 to 60 PSIG Instrument
Supply RangeSupply Manifold
Stainless Steel, Aluminum, Cast
Iron
Needle Valves Call For More Information Shut Off Valve316 Stainless Steel, Carbon Plated Steel
Gas Regulators - Marsh Bellofram
Burner Control Regulators
Water/Process Liquid Regulators
Steam Regulators
www.mvandc.com 17
Diaphragm Gas MetersThe G4 should be used for indoor low usage submetering applications and comes standard with pulse output. The 250-1000A meters are all manufactured by Itron and can be used for indoor or in harsh outdoor weather conditions. The Metris 250 and 400A are well known for their compact and long life design. The 675A-1000A meters are known for their high quality and high capacities actually exceeding the base rating of the meter.
675A790 CFH25 PSIGNTC/TC
1" TO 1-1/2"
800A890 CFH25 PSIGNTC/TC
1-1/4, 1-1/2"
1000A1040 CFH25 PSIGNTC/TC
1-1/4, 1-1/2", 2"
400A400 CFH MAX10 OR 25 PSIG
MAXNTC OR TC
3/4" TO 1-1/2"
METRIS 250250 CFH MAX5 PSIG MAXNTC OR TC
3/4, 1"
G4200 CFH MAX5 PSIG MAXNTC ONLY
3/4, 1"
Gas Meters - Diaphragm and Turbine
Turbine Gas MetersThe SZ and Q400 turbine meters are ideal for low cost, indoor applications requiring a pulse output. The SZ line comes with permanently lubricated bearings so no oil is required at start-up or during the useful life of the meter. The Mark II turbine meters are used by gas utilities and in commercial/industrial applications for medium to high flow rate applications. Mark II meters are available in all pressure classes and 4-12” sizes. The Mark II is available with auto-adjust (AAT) calibrating impeller which provides real time accuracy monitoring and makes necessary adjustments. The GTS series is available in 3-12” sizes in all pressure classes. The GTX series offers a lower cost solution in 4-8” sizes and includes permanently lubricated bearings so no oiling is required during the life of the meter.
SZ TURBINE/ Q400900 - 25,000 CFH MAX
175 PSIG MAXNTC ONLY
1”NPT, 1-1/2” NPT, 2”-4” WAFER,
4” FLANGED (Q400)
MARK II18,000 – 230,000 CFH MAX240, 720, 1440 PSIG MAX
NTC ONLY4” – 12” FLANGED
AUTO-ADJUST OPTION
GTX/GTS10,000 TO 150,000 CFH MAX
175, 740, 1480 PSIG MAXNTC ONLY3” WAFER
GTS 4”–12” FLANGEDGTX 4”-8” FLANGED (175 PSIG)
Gas Meters – Ultrasonic and Thermal Mass
FLOWSIC500 - Ultrasonic • Ultrasonic measurement • No moving parts • No straight pipe required • Temperature and/or
pressure correction option • Self diagnostics
• Battery powered • Sizes/Flow Ranges
o 2”/46 to 5,650 cfh o 3”/88 to 14,125 cfh o 4”/141 to 23,000 cfh o 6”/141 to 35,314 cfh
• Amb Temp -40 to 158 Deg F • Pressure – 285 psi max • Enclosure Rating IP65 • Outputs – (1) Digital, (1) RS-
485 or (1) optical • Orientation – horz/vert
FLOWSIC600 - Ultrasonic
• Ultrasonic measurement • Direct 2, 4, 4+1 or 4+4 path • Bidirectional measurement • Rangeability up to 130 to1 • Self diagnostics • Integrated datalogging
• 2 to 48” diameters • Flow ranges dependent upon
diameter • Outputs - (1) analog, (3) digital,
RS-485, modbus ASCI II, Modbus RTU, Hart
• Amb Temp -40 to 140 Deg F • Pressure – 3,626 psig max • Enclosure rating IP67 • Suitable for natural gas,
custody transfer (4 path), biogas, process gas
Thermal Mass - Insertion Style – Standard (2 Sensor Design)
• Insertion style • Monitor flow rate and total • Accuracy +/- 1% of reading
plus 0.5% of full scale • Input power 18-30 VDC or
100-240 VAC
• Gas temp -40 to 350 F • Ambient temp -40 to 120 F • Max pressure 230 psi • Pulse, flow rate, Modbus
RTU, Hart outputs • Little to no straight pipe
• Pressure and temperature corrected readings
• Display 2x12 LCD • 316 SS Wetted parts • CE, CSA, ATEX, FM, IP65,
Nema 4X • Hot tap kits available
Thermal Mass – Inline – Standard (2 Sensor Design)
• Inline style • ¼” to 8” npt • 1” to 8” Flanged • Accuracy +/- 1% of reading
plus 0.5% of full scale • Input power 18-30 VDC or
100-240 VAC
• High temperature option to 750 Deg F
• Max pressure 230 psi • Pulse, flow rate, Modbus RTU,
Hart outputs • Straight pipe required
• Pressure and temperature corrected readings
• Display 2x12 LCD • 316 SS Wetted parts • CE, CSA, ATEX, FM, IP65,
Nema 4X
Thermal Mass - Insertion and Inline – High Accuracy (4 Sensor Design)
Thermal Mass – Insertion – Least Cost
• Inline or insertion style • 4 path sensor technology • Insertion – 1 to 48” • Inline – ½” to 8” • Accuracy +/-0.5% above
50% of full scale flow, 1% otherwise.
• Input power 24 VDC or 100-240 VAC
• Gas temp -40 to 392 F • Ambient temp -40 to 120 F • Pressure ranges 30, 100,
300, 500 psia • Display 2x12 LCD
• Mass flow and temperature readings (std), pressure (optional)
• 4-20mA, temp and pressure outputs
• See brochure for straight pipe requirements
• Insertion style • Economical and easy install • Natural gas, propane,
methane • 1 to 6” pipe sizes • Accuracy +/- 3 or 1% of full
scale • Input power 15-18 VDC • 0 to 120 psig
• Display 2x12 LCD displaying total
• 316 SS wetted parts • CE, Nema 4X • 3/8” compression fitting • Software interface • Pulse, 0-5 VDC and 4-20mA
proportional to mass flow, Modbus RTU
• Upstream/downstream straight pipe required
• Typical calibrated max flow rates (Sch 40, 1 atm, 70F) o 1.25”/ 0 to 4,800 scfh o 1.5”/0 to 6,600 scfh o 2”/0 to 11,100 scfh o 2.5”/0 to 15,900 scfh o 3”/0 to 24,600 scfh o 4”/141 to 42,300 cfh o 6”/0 to 96,000 scfh
877.566.383718
Rotary Meters
Delta Compact
The Itron Delta rotary meter is the most compact rotary meter in the US market with a 2M capacity. This meter has a standard counter and low frequency pulse output.
METER BASE RATING FLANGE X FLANGE HEAD TO TAIL HEIGHT WEIGHT(LBS)
DC2M-NPT-1.5"-CF 2000 ACFH 4.75" 7.95" 4.96" 10
DC2M-2"-CF 2000 ACFH 6.75" 8.5" 4.96" 14
Dresser Roots Series B3
The Dresser Roots series B rotary meters are gas meters designed to provide highly accurate gas measurement over a very wide range of flow, pressure and temperature conditions. Options for the meters include the standard counter, instrument drive, temperature compensation, pulse output and integral volume correctors.
Units 8C175 15C175 2M175 3M175 5M175 7M175 11M175 16M175 23M232 38M175 56M175
Pipe Size in. 2 2 2 2 3 3 4 4 4 6 8
Base Rating acfh 800 1,500 2,000 3,000 5,000 7,000 11,000 16,000 23,000 38,000 56,000
Flg/Flg Dim. in. 6.75 6.75 6.75 6.75 6.75 9.50 9.50 9.50 9.50 18 21
Diff. 100% Flow in w.c. 0.45 0.75 0.65 1.10 1.10 1.60 1.06 2.10 2.08 1.90 2.20
Net Weight lbs. 22 27 30 33 38 58 75 86 100 247 287
Romet RM Imperial Series
Romet RM Imperial series rotary gas meters are offered in a wide variety of sizes all while keeping accuracy in mind. Options for the meters include the standard counter, instrument drive, temperature compensation, pulse output and integral corrector options.
Units RM1000 RM1500 RM2000 RM3000 RM5000 RM7000 RM11000 RM16000 RM23000
Pipe Size in. 2 2 2 2 3 3 4 4 4
Base Rating acfh 1,000 1,500 2,000 3,000 5,000 7,000 11,000 16,000 23,000
Flg/Flg Dim. in. 6.75 6.75 6.75 6.75 6.75 9.50 9.50 9.50 9.50
Diff. 100% Flow in w.c. 0.46 0.53 0.59 0.67 0.74 0.80 0.82 1.42 1.92
Net Weight lbs. 15 16 26 27 32 48 60 62 78
Gas Meters – Ultrasonic and Thermal Mass
FLOWSIC500 - Ultrasonic • Ultrasonic measurement • No moving parts • No straight pipe required • Temperature and/or
pressure correction option • Self diagnostics
• Battery powered • Sizes/Flow Ranges
o 2”/46 to 5,650 cfh o 3”/88 to 14,125 cfh o 4”/141 to 23,000 cfh o 6”/141 to 35,314 cfh
• Amb Temp -40 to 158 Deg F • Pressure – 285 psi max • Enclosure Rating IP65 • Outputs – (1) Digital, (1) RS-
485 or (1) optical • Orientation – horz/vert
FLOWSIC600 - Ultrasonic
• Ultrasonic measurement • Direct 2, 4, 4+1 or 4+4 path • Bidirectional measurement • Rangeability up to 130 to1 • Self diagnostics • Integrated datalogging
• 2 to 48” diameters • Flow ranges dependent upon
diameter • Outputs - (1) analog, (3) digital,
RS-485, modbus ASCI II, Modbus RTU, Hart
• Amb Temp -40 to 140 Deg F • Pressure – 3,626 psig max • Enclosure rating IP67 • Suitable for natural gas,
custody transfer (4 path), biogas, process gas
Thermal Mass - Insertion Style – Standard (2 Sensor Design)
• Insertion style • Monitor flow rate and total • Accuracy +/- 1% of reading
plus 0.5% of full scale • Input power 18-30 VDC or
100-240 VAC
• Gas temp -40 to 350 F • Ambient temp -40 to 120 F • Max pressure 230 psi • Pulse, flow rate, Modbus
RTU, Hart outputs • Little to no straight pipe
• Pressure and temperature corrected readings
• Display 2x12 LCD • 316 SS Wetted parts • CE, CSA, ATEX, FM, IP65,
Nema 4X • Hot tap kits available
Thermal Mass – Inline – Standard (2 Sensor Design)
• Inline style • ¼” to 8” npt • 1” to 8” Flanged • Accuracy +/- 1% of reading
plus 0.5% of full scale • Input power 18-30 VDC or
100-240 VAC
• High temperature option to 750 Deg F
• Max pressure 230 psi • Pulse, flow rate, Modbus RTU,
Hart outputs • Straight pipe required
• Pressure and temperature corrected readings
• Display 2x12 LCD • 316 SS Wetted parts • CE, CSA, ATEX, FM, IP65,
Nema 4X
Thermal Mass - Insertion and Inline – High Accuracy (4 Sensor Design)
Thermal Mass – Insertion – Least Cost
• Inline or insertion style • 4 path sensor technology • Insertion – 1 to 48” • Inline – ½” to 8” • Accuracy +/-0.5% above
50% of full scale flow, 1% otherwise.
• Input power 24 VDC or 100-240 VAC
• Gas temp -40 to 392 F • Ambient temp -40 to 120 F • Pressure ranges 30, 100,
300, 500 psia • Display 2x12 LCD
• Mass flow and temperature readings (std), pressure (optional)
• 4-20mA, temp and pressure outputs
• See brochure for straight pipe requirements
• Insertion style • Economical and easy install • Natural gas, propane,
methane • 1 to 6” pipe sizes • Accuracy +/- 3 or 1% of full
scale • Input power 15-18 VDC • 0 to 120 psig
• Display 2x12 LCD displaying total
• 316 SS wetted parts • CE, Nema 4X • 3/8” compression fitting • Software interface • Pulse, 0-5 VDC and 4-20mA
proportional to mass flow, Modbus RTU
• Upstream/downstream straight pipe required
• Typical calibrated max flow rates (Sch 40, 1 atm, 70F) o 1.25”/ 0 to 4,800 scfh o 1.5”/0 to 6,600 scfh o 2”/0 to 11,100 scfh o 2.5”/0 to 15,900 scfh o 3”/0 to 24,600 scfh o 4”/141 to 42,300 cfh o 6”/0 to 96,000 scfh
www.mvandc.com 19
Ultrasonic & Thermal Mass Meters
877.566.383720
Gas Meter Sizing
SIZES READILY METER METER CAPACITY (SCFH) AT OPERATING PRESSURES (PSIG), NATURAL GAS
AVAILABLE4 MODEL # TYPES 7”WC (BASE) 14”WC 1 2 3 5 10 25
DIAPHRAGM METERS - 3/4” TO 2”
3/4 &1” (INDOOR) MTW G4 DIAPHRAGM 211 211 221 235 249 278 - -
3/4 &1” METRIS 250 DIAPHRAGM 250 610 638 679 721 803 - -
3/4, 1, 1.25, 1.5 400A DIAPHRAGM 400 860 899 958 1,016 1,133 1,425 2,300
1, 1.25 675A DIAPHRAGM 790 1,675 1,751 1,865 1,979 2,206 2,775 4,480
1.25, 1.5” 800A DIAPHRAGM 890 1,930 2,018 2,149 2,280 2,542 3,197 5,162
1.25, 1.5, 2” 1000A DIAPHRAGM 1,040 2,215 2,316 2,466 2,617 2,917 3,669 5,925
ROTARY METERS - 2” TO 8”
2” 8C ROTARY 800 814 841 900 1,000 1,100 1,300 2,200
2” 1M ROTARY 1,000 1,017 1,051 1,100 1,200 1,300 1,700 2,700
2” 1.5M ROTARY 1,500 1,526 1,577 1,700 1,800 2,000 2,500 4,000
2” 2M ROTARY 2,000 2,034 2,102 2,300 2,400 2,700 3,400 5,400
2” 3M ROTARY 3,000 3,051 3,154 3,400 3,600 4,000 5,000 8,100
2” & 3” 5M ROTARY 5,000 5,086 5,256 5,700 6,000 6,700 8,400 13,500
2” & 3” 7M ROTARY 7,000 7,120 7,358 8,000 8,400 9,400 11,800 18,900
2”, 3” & 4” 11M ROTARY 11,000 11,188 11,563 12,500 13,200 14,700 18,500 29,700
4” 16M ROTARY 16,000 16,274 16,819 18,200 19,300 21,400 26,900 43,200
4” 23M ROTARY 23,000 23,393 24,178 26,100 27,700 30,800 38,600 62,000
4” & 6” 38M ROTARY 38,000 38,650 39,946 43,200 45,700 50,900 63,800 102,500
4” & 8” 56M ROTARY 56,000 56,958 58,867 54,000 64,500 75,000 94,000 151,000
ULTRASONIC METERS - 2” TO 6”
2” 5.5M ULTRASONIC 5,600 5,725 5,850 6,235 6,620 7,380 9,280 14,980
3” 14M ULTRASONIC 14,000 14,320 14,640 15,590 16,540 18,440 27,940 37,450
4” 23M ULTRASONIC 23,000 23,525 24,050 25,610 27,170 30,290 38,100 61,520
6” 35M ULTRASONIC 35,000 35,795 36,590 38,965 41,340 46,100 57,980 93,620
TURBINE METERS - 1” TO 12”
1” SZ-1 TURBINE 900 915 950 1,020 1,070 1,200 1,500 2,430
1” SZ-2 TURBINE 1,500 1,525 1,575 1,700 1,780 2,000 2,500 4,050
1-1/2” SZ-40 TURBINE 2,300 2,340 2,420 2,610 2,730 3,080 3,860 6,210
2” SZ-65 TURBINE 3,500 3,560 3,680 3,975 4,160 4,690 5,880 9,450
3” SZ-100 TURBINE 5,600 5,695 5,885 6,360 6,650 7,500 9,410 15,125
3” SZ-160 TURBINE 8,800 8,950 9,250 9,990 10,450 11,795 14,785 23,765
4” SZ-250 TURBINE 15,000 15,255 15,770 17,040 17,815 20,100 25,200 40,500
4” Q-400 TURBINE 24,000 24,500 25,000 26,500 28,000 31,000 39,000 62,000
4”-12” MARK II TURBINE Capacities vary depending upon pipe size and pressure. See technical brochure for sizing.
3”-12” GTX/GTS TURBINE Capacities vary depending upon pipe size and pressure. See technical brochure for sizing.
THERMAL MASS METERS – 1” AND GREATER
1/4” AND UP 620/640/720 INSERTION/INLINE Capacities vary depending upon pipe size, pressure and calibration. See technical brochure for sizing.
Information Needed to Size Gas MetersSizing Table Notes
1. 7”WC – Capacities shown reflect a 0.5”wc pressure drop across the meter for G4-1000A meters.
2. 14”WC - Capacities shown reflect a 2”wc pressure drop across the meter for 250-1000A meters.
3. Refer to technical manuals for pressure drops at specific capacities for turbine, rotary, ultrasonic, and thermal mass meters.
4. BTUH/1000 = SCFH
1. Gas Type (Natural Gas, Propane, etc.)2. Max Flow Rate (CFH or BTUH)3. Meter Pressure (PSIG or “ WC)4. Pipe Size (Inches)5. Indoor or Outdoor Installation6. Optional Information to Provide (Orientation, Pulse Output,
Pressure and /or Temperature Correction, Wireless, 4-20 mA, Modbus, etc.)
www.mvandc.com 21
Gas Strainers
ITEM MODEL PIPE ANSI CONN MICRON/MESH
TYPE MANUFACTURER NO SIZE CLASS TYPE RATING PICTURE
GASKET STRAINER
GS-2 2"
ANSI 150 ANSI 300
RING OR
FULL FACE
Mesh Ratings - 20, 40, 60, 80, 100 or
120.
GS-3 3"
GS-4 4"
GS-6 6"
GS-8 8"
T (90 DEG) STRAINERS NPT
STR-T-IMAC-1"-NPT 1"
CLASS 125 NPTMesh Ratings - 20, 40, 60, 80, 100 or
120.
STR-T-IMAC-1.5"-NPT 1.5"
STR-T-IMAC-2"-NPT 2"
STR-T-IMAC-3"-NPT 3"
STR-T-IMAC-4"-NPT 4"
T (90 DEG) STRAINERS FLG
STR-T-IMAC-2"-FLG 2"
CLASS 125 FLGMesh Ratings - 20, 40, 60, 80, 100 or
120. STR-T-IMAC-3"-FLG 3"
STR-T-IMAC-4"-FLG 4"
Y STRAINERS NPT
STR-YS-12-CI-1/2"-NPT 1/2"
MAX P = 250 PSI
NPT
Mesh Ratings - 60 (std), others
available upon request
STR-YS-12-CI-3/4"-NPT 3/4"
STR-YS-12-CI-1"-NPT 1"
STR-YS-12-CI-1.25"-NPT 1.25"
STR-YS-12-CI-1.5"-NPT 1.5"
STR-YS-12-CI-2"-NPT 2"
STR-YS-12-CI-2.5"-NPT 2.5"
STR-YS-12-CI-3"-NPT 3"
Y STRAINERS FLG
STR-YS-58-CI-2"-FLG 2"
CLASS 125 FLG
Mesh Ratings - 60 (std), others
available upon request
STR-YS-58-CI-3"-FLG 3"
STR-YS-58-CI-4"-FLG 4"
STR-YS-58-CI-6"-FLG 6"
STR-YS-58-CI-8"-FLG 8"
STR-YS-58-CI-10"-FLG 10"
STR-YS-58-CI-12"-FLG 12"
Call for larger sizes to 24" 24"
Y STRAINERS NPT
STR-ME650S-DI-1/2"-NPT 1/2"
MAX P = 600 PSI
NPT
Mesh Ratings - 20, 40 and 80. Plug
not included unless specified.
STR-ME651S-DI-3/4"-NPT 3/4"
STR-ME652S-DI-1"-NPT 1"
STR-ME653S-DI-1.25"-NPT 1.25"
STR-ME654S-DI-1.5"-NPT 1.5"
STR-ME655S-DI-2"-NPT 2"
STR-ME656S-DI-3"-NPT 3"
877.566.383722
Gas Filters
ITEM PIPE ANSI CONN TOP MICRON TYPE MANUFACTURER BASE MODEL NO SIZE CLASS TYPE STYLE RATING PICTURE
C-SERIES STYLE 1
C2-180/285 2" 180 PSIG
OR ANSI 150 (285
PSIG)
FLG (STD) NPT
WELD
QUICK OPEN
(STD), BF, KO
0.3 C3-180/285 3"
C4180/285 4"
C6-180/285 6"
C-SERIES STYLE 2
C2-740/1480 2"ANSI 150
300/600
FLG OR WELD
BF (STD) OR KO
0.3 C3-740/1480 3"
C4-740/1480 4"
C8-285 8"
C-SERIES STYLE 3
C6-740/1480 6"
ANSI 150/300
600
FLG OR WELD
BF (STD) OR KO
0.3
C8-740/1480 8"
C10-285/740/1480 10"
C12-285/740/1480 12"
C-SERIES STYLE 4
C10-1480 10" ANSI
600FLG OR WELD
BF 0.3 C12-1480 12"
Coalescing Filters
ITEM BASE PIPE PRESS CONN TOP MICRON TYPE MANUFACTURER MODEL NO SIZE CLASS TYPE STYLE RATING PICTURE
IN-LINE
PHILPOTT
F-CFR-3/4" 3/4"
150 PSI NPT NA5
MICRON
F-CFR-1" 1"
F-125S 1.25"
F-150S 1.5"
F-200S 2"
F SERIES STYLE 1
F1.5M-180 1.5"180
PSIG OR
ANSI 150 (285
PSIG)
FLG (STD) NPT
WELD
QUICK OPEN (STD), BLIND
FLG (BF), KNOCK-OFF (KO)
10 (STD) OR 5
F2M-180 2"
F1.5-180/285 1.5"
F2-180/285 2"
F3-180/285 3"
F4180/285 4"
F6-180/285 6"
F SERIES STYLE 2
F2-740/1480 2"
ANSI 300/600
FLG OR WELD
BF (STD) OR KO
10 (STD) OR 5
F3-740/1480 3"
F4-740/1480 4"
F SERIES STYLE 3
F6-740/1480 6"ANSI
150/300 600
FLG OR WELD
BF (STD) OR KO
10 (STD) OR 5
F8-740/1480 8"
F10-285/740/1480 10"
F12-285/740/1480 12"
F SERIES STYLE 3
F10-1480 10" ANSI
600FLG OR WELD
BF10 (STD)
OR 5 F12-1480 12"
Dry Particulate Filters
www.mvandc.com 23
XARTU/1 Volume Corrector• Single and bi-directional versions available.• AGA7, AGA8 (detail and gross method 1 & 2), &
NX19• API chapter 21 compliant• Configurable for forward, reverse, and net
volumes• Ultrasonic & coriolis applications available• All wireless options supported• Optional LDVI
XARTU/1 Orifice Flow Computer• API chapter 21 compliant• AGA3, AGA8, (detail and gross method 1 & 2), &
NX19• Single and bi-directional measurement• Multiple run capability• All wireless option supported
XARTU/1 Pressure Recorder• Up to 6 individual pressure measurements• Pressure control at city gate stations• Compressor suction, recirculation, and discharge
pressure control programmability• Storage well testing• Seasonal Injection and withdrawal• Pressure scan of 1/sec or less depending on user
requirements
XARTU/1 Volume Accumulator• Accepts high or low frequency pulses• Up to 4 meters connected simultaneously• All wireless options supported• Optional LDVI
XARTU/1 Remote Terminal Unit (RTU)• Configurable as a drop in operational replacement
for many legacy RTU’s• Configurable as either a MODBUS master or
MODBUS slave• Supports most manufactures wired and wireless
communications products• Software programmable to handle most
measurement, control, data gathering and alarm functions
XARTU/1 Cathodic Protection• 110/220vAC design with battery back-up• Programmable historical data storage• Sample and hold precision surge suppression
rectifier monitoring• GPS interruption available for synchronized
interrupting and testing
MP PLUS Volume Corrector• AGA5, AGA7, NX-19, AGA8 (detail and gross
methods)• Optional LVDI (vertical), that imposes very little
drag on the meter index drive, for 10ft³ drive and above
• Universal turbine and positive displacement meter mounting plate
• Available in single and bi-directional meter rotation
Transfer Prover• Prover electronics XARTU-TP• Detachable high frequency pulser • Master meter• Net weight 3M only 85lbs• NEMA 4X enclosure with 4-line LCD and keypad
Wireless Remote I/O• Distributed wired or wireless I/O• Communications support RS232, RS485 (2-wire
and 4-wire), Zigbee• MODBUS protocol (can be used with 3rd party
RTU’s)• Configure up to 8 in one network
Plunger Lift• Analyze and adaptively control production• Control the dropping of the plunger into the well• Attempt to assure that it makes a full trip on each
run
Process Controller• Pneumatic or current analog output options• Pressure,temperature, differential pressure, pulses
or an AGA calculation of flow, and the PID logic is performed electronically
• Built-in battery allows continued control with DC power loss
• Stand alone or remote set point change options• 12 or 24 volt A/C or solar
Solenoid Control• Remote control of pressure or flow• No need for process piping modifications• Operate self-contained or pilot operated pressure
regulators• Control diaphragm actuated instrument valves
Gas Control/Electronics - Eagle Research
877.566.383724
Gas Accessories - IMAC
Valvitalia2 - 30" Sizes StockedASME VII Div I-App 2
NACE MRO 175
Factory AssembledFactory Tested2 - 30" Sizes
ANSI 150/300/600
Pete's Plug IIPressure and
Temperature Test Plug,Rotary Meter Oil fill
Applications
Thermcat HeatersFM/CSA Certified
Pilot Space or PipeHeaters
Market LeaderFD-19, FD-4, FD-5Quick Lead TimesCustom Designs
Gasket & T-Strainers (90˚)
20/40/60/80/100/120Mesh
Fits all ID MetersPulse Rates of 1, 2, 5,10, 20, 50, and 100
Single or Dual Outputs
Asbestos FreeGaskets
1 - 12", ANSI150/300/600
PTFE Yellow Seal Gas Tape
Stainless Steel Tape
Used and RefurbishedDiaphragm, Rotary and
Turbine Meters
Repair of Diaphragm,Rotary and Turbine
Meters
Quick Shot TurbineOiler
Rotary Meter OilerRotary Meter Oil Drain
Custom AluminumScreen Vents for Gas
Regulator Vents,Valve Breathers and
More
Protects Gas RegulatorVent Lines From
Water Intrusion inVaults, Pits, or Areas Subject to Flooding
Itron Gas RegulatorSpring and OrificeAdjustment Tools,Regulator Flange
Spacers
¾ and 1" Inlet1" and 2" Outlet
Relief Setpoings from0.5 to 300 PSIG
www.mvandc.com 25
Earthquake Valves - PSPEarthquake Valves – Pacific Seismic Products
The “California Valve” manufactured by Pacific Seismic Products (formerly Koso) includes the most complete line of mechanical earthquake valves on the market today. Valves are offered in multiple orientations (horizontal, vertical bottom inlet and vertical top inlet), sizes (3/4" through 8") and pressure classes (7 psig and 60 psig max). All valves are UL certified, approved by the State of California, City of Los Angeles and are manufactured in accordance with ASCE 25-06.
Threaded Valves
NPT VALVE DIMENSIONS PIPE MODEL # FOR FLOW DIRECTION MAX LENGTH HEIGHT WIDTH SHIP
SIZE HORZ UP DOWN PSIG A B C WEIGHT
(LBS)
3/4" 300-7 VB-300-7 VT-300-7 7 4" 4-3/4" 3-7/8" 4
3/4" 310-60 VB-310-60 VT-310-60 60 4" 4-3/4" 3-7/8" 4
1" 301-7 VB-301-7 VT-301-7 7 4" 4-3/4" 3-7/8" 4
1" 311-60 VB-311-60 VT-311-60 60 4" 4-3/4" 3-7/8" 4
1-1/4" 302-7 VB-302-7 VT-302-7 7 5-1/4" 5" 3-7/8" 5
1-1/4" 312-60 VB-312-60 VT-312-60 60 5-1/4" 5" 3-7/8" 5
1-1/2" 303-7 VB-303-7 VT-303-7 7 5-1/4" 5" 3-7/8" 5
1-1/2" 313-60 VB-313-60 VT-313-60 60 5-1/4" 5" 3-7/8" 5
2" 314-60 VB-314-60 VT-314-60 60 5-5/8" 5-1/4" 3-7/8" 6
2-1/2" 318-60 VB-318-60 VT-318-60 60 8-1/8" 5-1/8" 4-3/4" 9
3" 315-60 VB-315-60 VT-315-60 60 8-1/8" 5-1/8" 4-3/4" 12
4" 316-60 VB-316-60 VT-316-60 60 8-3/8" 6-1/4" 5-3/4" 15
Flanged Valves
FLANGED VALVE DIMENSIONS PIPE MODEL # FOR FLOW DIRECTION MAX LENGTH HEIGHT WIDTH DIA # BOLT SHIP
SIZE HORZ UP DOWN PSIG A B C D HOLES WEIGHT
(LBS)
2" 314F-60 VB-314F-60 VT-314F-60 60 7-1/8" 5-3/8" 6" 4-3/4" 4 9
2-1/2" 318F-60 VB-318F-60 VT-318F-60 60 7-1/2" 5-3/8" 7" 5-1/2" 4 10
3" 315F-60 VB--315F-60 VT--315F-60 60 7-1/2" 5-3/8" 7-1/2" 6" 4 12
4" 316F-60 VB-316F-60 VT-316F-60 60 7-1/2" 6-3/8" 9" 7-1/2" 8 17
6" 317F-60 VB-317F-60 VT-317F-60 60 12-1/2" 7-1/2" 11" 9-1/2" 8 31
8" 319F-60 VB-319F-60 VT-319F-60 60 16-3/8" 9-5/8" 13-1/2" 11-3/4" 8 52
Earthquake Valves – Pacific Seismic Products
The “California Valve” manufactured by Pacific Seismic Products (formerly Koso) includes the most complete line of mechanical earthquake valves on the market today. Valves are offered in multiple orientations (horizontal, vertical bottom inlet and vertical top inlet), sizes (3/4" through 8") and pressure classes (7 psig and 60 psig max). All valves are UL certified, approved by the State of California, City of Los Angeles and are manufactured in accordance with ASCE 25-06.
Threaded Valves
NPT VALVE DIMENSIONS PIPE MODEL # FOR FLOW DIRECTION MAX LENGTH HEIGHT WIDTH SHIP
SIZE HORZ UP DOWN PSIG A B C WEIGHT
(LBS)
3/4" 300-7 VB-300-7 VT-300-7 7 4" 4-3/4" 3-7/8" 4
3/4" 310-60 VB-310-60 VT-310-60 60 4" 4-3/4" 3-7/8" 4
1" 301-7 VB-301-7 VT-301-7 7 4" 4-3/4" 3-7/8" 4
1" 311-60 VB-311-60 VT-311-60 60 4" 4-3/4" 3-7/8" 4
1-1/4" 302-7 VB-302-7 VT-302-7 7 5-1/4" 5" 3-7/8" 5
1-1/4" 312-60 VB-312-60 VT-312-60 60 5-1/4" 5" 3-7/8" 5
1-1/2" 303-7 VB-303-7 VT-303-7 7 5-1/4" 5" 3-7/8" 5
1-1/2" 313-60 VB-313-60 VT-313-60 60 5-1/4" 5" 3-7/8" 5
2" 314-60 VB-314-60 VT-314-60 60 5-5/8" 5-1/4" 3-7/8" 6
2-1/2" 318-60 VB-318-60 VT-318-60 60 8-1/8" 5-1/8" 4-3/4" 9
3" 315-60 VB-315-60 VT-315-60 60 8-1/8" 5-1/8" 4-3/4" 12
4" 316-60 VB-316-60 VT-316-60 60 8-3/8" 6-1/4" 5-3/4" 15
Flanged Valves
FLANGED VALVE DIMENSIONS PIPE MODEL # FOR FLOW DIRECTION MAX LENGTH HEIGHT WIDTH DIA # BOLT SHIP
SIZE HORZ UP DOWN PSIG A B C D HOLES WEIGHT
(LBS)
2" 314F-60 VB-314F-60 VT-314F-60 60 7-1/8" 5-3/8" 6" 4-3/4" 4 9
2-1/2" 318F-60 VB-318F-60 VT-318F-60 60 7-1/2" 5-3/8" 7" 5-1/2" 4 10
3" 315F-60 VB--315F-60 VT--315F-60 60 7-1/2" 5-3/8" 7-1/2" 6" 4 12
4" 316F-60 VB-316F-60 VT-316F-60 60 7-1/2" 6-3/8" 9" 7-1/2" 8 17
6" 317F-60 VB-317F-60 VT-317F-60 60 12-1/2" 7-1/2" 11" 9-1/2" 8 31
8" 319F-60 VB-319F-60 VT-319F-60 60 16-3/8" 9-5/8" 13-1/2" 11-3/4" 8 52
877.566.383726
The Little Firefighter Automatic Shut-Off Valve is the most lightweight and compact valve sold on the market. Automatically shuts off gas when triggered by a significant seismic event. Easy 1/8 turn of coin slot for emergency manual shut-off. Valves are offered in multiple orientations (horizontal and vertical top inlet), sizes (3/4" through 4") and pressure classes (2, 5, 10 and 60 psig max). All valves are CSA certified, approved by the State of Cali-fornia, City of Los Angeles and are manufactured in accordance with ASCE 25-06.
PIPE CONN MAX VALVE VALVE VALVE SHIP CASE
MODEL NO SIZE TYPE PSI OREINTATION LENGTH WIDTH HEIGHT WEIGHT QTY
HORZ-5 PSI
EV-AGV-075 3/4" THD 5 PSI HORZ 3" 1.5" 3" 2# 12
EV-AGV-100 1" THD 5 PSI HORZ 4" 1.75" 3.5" 3# 12
EV-AGV-125 1-1/4" THD 5 PSI HORZ 4" 2.33" 4.66" 4# 12
EV-AGV-150 1-1/2" THD 5 PSI HORZ 6" 3" 5.5" 9# 1
EV-AGV-200 2" THD 5 PSI HORZ 6" 3" 5.5" 9# 1
HORZ-60 PSI
EV-AGV-150HP 1-1/2" THD 60 PSI HORZ 6" 3" 5.5" 9# 1
EV-AGV-200HP 2" THD 60 PSI HORZ 6" 3" 5.5" 9# 1
EV-AGV-250 2-1/2" THD 60 PSI HORZ 6.8" 3.6" 6.2" 11# 1
EV-AGV-300 3" THD 60 PSI HORZ 8.5" 4.5" 8.2" 16# 1
EV-AGV-400 4" THD 60 PSI HORZ 10.1" 5.9" 9.0" 25# 1
VERT-10 PSI
EV-VAGV-075 3/4" THD 10 PSI VERT 2.5" 2" 3.375" 2# 12
EV-VAGV-100 1" THD 10 PSI VERT 2.5" 2" 3.375" 2# 12
EV-VAGV-125 1-1/4" THD 10 PSI VERT 2.5" 2" 3.4" 2# 12
VERT-2 PSI
EV-VAGV-125HF 1-1/4" THD 2 PSI VERT 4.2" 3.33" 5.2" 7# 1
EV-VAGV-150 1-1/2" THD 2 PSI VERT 4.2" 3.33" 5.2" 8# 1
EV-VAGV-200 2" THD 2 PSI VERT 4.2" 3.33" 5.2" 8# 1
VERT-60 PSI
EV-VAGV-150HP 1-1/2" THD 60 PSI VERT 4.2" 3.33" 5.2" 7# 1
EV-VAGV-200HP 2" THD 60 PSI VERT 4.2" 3.33" 5.2" 7# 1
90 DEG-5 PSI
EV-NAGV-075 3/4" THD 5 PSI 90 3.2" 2" 3" 2# 12
EV-NAGV-100 1" THD 5 PSI 90 3.2" 2" 3.1" 2# 12
EV-NAGV-125 1-1/4" THD 5 PSI 90 3.3" 2" 3.1" 2# 12
Earthquake Valves - Little Fire Fighter
www.mvandc.com 27
Propane
Max Outlet
Size Inlet Pressure Max
Model Manufacturer (inches) Pressure Range Capacity (LP) Picture
1st Stage Propane Regulators
R122H (AAJ) 1/4" X 1/2" FPT 250 PSIG 8 to 12 PSIG 1,100,000 BTU
R622H (JGJ & DGJ)
FPOL X 3/4" FPT/ 3/4" X 3/4" FPT
125 PSIG 8 to 12 PSIG2,250,000 BTU (JGJ)/ 2,400,000 BTU (DGJ)
MEGR-1622H (JGJ)
3/4" FPT 250 PSIG 9 to 12 PSIG 2,300,000 BTU
TL627 3/4", 1", 2" NPT 250 PSIG 5 to 40 PSIG25,200,000 BTU (5 & 10 PSIG Set Point)
T37 1/2", 3/4" NPT 400 PSIG 10 to 125 PSIG7,000,000 BTU (10
PSIG Set Point)
T38 1" NPT 400 PSIG 10 to 125 PSIG9,000,000 BTU (10
PSIG Set Point)
T39 1/4" NPT 6000 PSIG 0 to 120 PSIG 3,800,000 BTU
2nd Stage Propane Regulator
R222-BAF 1/2" FPT 10 PSIG 9.5 to 13" WC 450,000 BTU
R622-DFF 3/4" FPT 10 PSIG 9 to 20" WC 1,400,000 BTU
R642-DFF 3/4" FPT X 3/4" (90°) 10 PSIG 9 to 20" WC 900,000 BTU
HSRL (BFC & CFC)
3/4" FPT (BFC)/ 1" FPT (CFC)
10 PSIG 9 to 13" WC2,300,000 BTU (BFC)/ 2,600,000 BTU (CFC)
1622-DFF 3/4" FPT 10 PSIG 9 to 13" WC 1,300,000 BTU
1652-DFF 3/4" FPT X 3/4" (90°) 10 PSIG 9 to 13" WC 1,000,000 BTU
B Series 1/2" to 3" See Full Line of Itron Regulators on Page 7
Governors 1/2" to 4" See Full Line of Pietro Governors on Page 10
Twin Stage Propane Regulator
R232 (BBF/HBF)
1/4" X 1/2" FPT (BBF)/ FPOL X 1/2"
FPT (HBF)250 PSIG 9 TO 13" WC 350,000 BTU
R632 (JFF/CFF)
FPOL X 3/4" FPT (JFF)/ 1/4" X 3/4" FPT
(CFF)250 PSIG 9.5 TO 13" WC 750,000 BTU
MEGR-1632-JFF
FPOL X 3/4" OUTLET 250 PSIG 9" TO 13" WC 900,000 BTU
Single Stage and Appliance Propane Regulators
T9121/4" NPT / 1/4" X 3/8"
NPT250 PSIG 9.25 to 13" WC 220,000 BTU
Governors 1/2" to 4" See Full Line of Pietro Governors on Page 10
Propane (LPG) Regulators
877.566.383728
Water Meters
I O CA
N R
D I C
O O P E E
Size Max Max Flow Connection Body O U I N R
Model Manufacturer (inches) Pressure T Range Type Material R T T T T Meter
AWWA C700 - Positive Displacement Water Meters
T10 5/8" to 2" 150 PSIG 149°F1/2 to 160
GPM
Threaded (5/8" - 2") and Flanged
(1.5"-2")
Lead Free High Copper
Alloy ✓ ✓ H ✓
Recordall Disc 5/8" to 2" 150 PSIG 80°F1/8 to 170
GPM
Threaded (5/8" - 2") and Flanged
(1.5"-2")
Lead Free Bronze & Poly-
mer (5/8-1") ✓ ✓ ✓H/ VU
✓ (5/8-1")
SR-II 5/8" to 1" 150 PSIG 120°F1 to 50 GPM
ThreadedEnviroBrass (Lead Free) ✓ H
accuSTREAM 5/8" to 1" 150 PSIG 150°F1/4 to
50 GPMThreaded
Polymer (Lead Free) ✓ H
SM15 5/8"x3/4" 150 PSIG 120°F1/8 to
20 GPMThreaded
Copper Alloy/ Bronze ✓ ✓ ✓ H
C700 5/8" to 2" 150 PSIG 120°F1 to 160
GPM
Threaded (5/8" - 1") and Flanged
(1.5"-2")
Lead Free Brass ✓ ✓ ✓ H ✓
AWWA C708 - Single/ Multi-Jet Water Meters
MJ20/ MJ420 3/4" 150 PSIG
105°F-MJ20/ 140°F-MJ420
1 to 20 GPM
ThreadedPolymer body/ Brass threads
(Lead Free)✓ A
Versamag 5/8"x3/4" 150 PSIG105°F (Cold)/
160°F (Hot)
1 to 20 GPM
ThreadedPolymer (Lead
Free) ✓ A
Multimag 3/4" to 2" 150 PSIG105°F (Cold)/
194°F (Hot)
1/2 to 160
GPMThreaded
Ecobrass (Lead Free) ✓ H
FAM 5/8" x 3/4" 150 PSIG 120°F1 to 20 GPM
ThreadedPolymer (Lead
Free) ✓ A ✓
BLMJ 5/8" to 1" 150 PSIG 120°F1 to 50 GPM
ThreadedLead Free Bronze/ Polymer
✓ ✓ H
MS-MJ 1.5" & 2" 150 PSIG 120°F5 to 160
GPMThreaded and
FlangedLead Free
Bronze ✓ ✓ H
1700 Series1/2" to 1-1/2"
150 PSIG 200°F1/10 to 90 GPM
ThreadedBrass/ Cast
Iron ✓ ✓ A
1800 Series 1/2" to 2" 232 PSIG 248°F1/10
to 132 GPM
Threaded / Flanged (2")
Brass/ Cast Iron ✓ ✓ A
MNL 1/2" to 2" 150 PSIG 122 °F1/4 to
160 GPM
ThreadedLead Free Eco
Brass ✓ ✓ H
AWWA C702 - Compound Water Meters
Tru/Flo 2" to 8" 150 PSIG 80°F1/2 to 2,000 GPM
FlangedLead Free
High Copper Alloy
✓ ✓ ✓ H
Recordall Compound
2" to 6" 150 PSIG 120°F1/4 to 1,500 GPM
FlangedCast Bronze/
Lead Free Alloy
✓ ✓ ✓ H
Omni C21-1/2" to
10"200 PSIG 150°F
1/2 to 4,000 GPM
FlangedCoated Ductile
Iron ✓ ✓ ✓ A
www.mvandc.com 29
Water Meters
I O CA
N R
D I C
O O P E E
Size Max Max Flow Connection Body O U I N R
Model Manufacturer (inches) Pressure T Range Type Material R T T T T Meter
AWWA C701 - Turbine Water Meters
MMT 2" to 8" 175 PSIG 150°F4 to
2,700 GPM
FlangedLead Free
EnviroBrass ✓ ✓ ✓ A
HP Turbine1-1/2" to
10"175 PSIG 80°F
4 to 6,500 GPM
FlangedLead Free
Copper Alloy ✓ ✓ ✓ H
Turbo1-1/2" to
12"150 PSIG 120°F
2-1/2 to 6,200 GPM
FlangedCast Bronze/
Low Lead Alloy
✓ ✓ ✓ H
Omni T21-1/2" to
10"200 PSIG 150°F
3/4 to 7,000 GPM
FlangedCoated Duc-
tile Iron ✓ ✓ ✓ A
T40001-1/2" to 6"
150 PSIG 120°F3 to
3,100 GPM
FlangedLead Free
Bronze ✓ ✓ ✓ A
TM 2" to 6" 230 PSIG
104°F (Cold)/ 194°F (Hot)
2 to 2,200 GPM
FlangedCast Iron. Ep-oxy Coated ✓ ✓ H
1800 Series (Woltmann
Design)2" to 12" 232 PSIG 248°F
2 to 5,284 GPM
Flanged Cast Iron ✓ ✓ A
Insertion Style Onicon Water Meters
F-1100 (Single Turbine)
1-1/2" to 36"
400 PSIG
180°F (STD)/ 280°F
(316SS)
4/5 to 60,900 GPM
InsertionElectroless
Nickel Plated Brass
✓ ✓
F-1200 (Bi-Directional)
2-1/2" to 36"
400 PSIG
180°F (STD)/ 280°F
(316SS)
2.5 to 60,900 GPM
InsertionElectroless
Nickel Plated Brass
✓ ✓
F-3500 Electromagnetic
3" to 36" 400 PSIG 250°F2.4 to 60,900 GPM
InsertionElectroless
Nickel Plated Brass
✓ ✓
In-Line Style Onicon Water Meters
F-1300 (In-Line Turbine)
3/4" & 1" 400 PSIG 180°F 4/5 to 38
GPMSweat/ Threaded Brass ✓ ✓ H
F-3100/3200 (In-Line
Electromagnetic)1" to 48"
230 to 580 PSIG
212°F1/5 to
182,596 GPM
Wafer/ FlangedCaron Steel/ 316 Stainless
Steel✓ ✓ H
Irigation Style Water Meters
1900 2" to 8" 230 PSIG 125°F 10-1/2
to 4,000 GPM
FlangedCoated Duc-
tile Iron ✓ ✓ H
101/102 3" to 36"150/ 300
PSIG100°F
80 to 24,000 GPM
FlangedDuctile Iron/ Fabricated
Steel✓ ✓ A
Ultrasonic Style Water Meters
E-Series 5/8" to 2" 175 PSIG 140°F 1/10
to 160 GPM
Threaded/ FlangedStainless
Steel/ Lead Free
✓ ✓ A
F-4200 (Clamp On)
1/2" to 48"
250°F1/3 to
218,800 GPM
Clamp On
Steel Enclo-sure/ Stain-less Steel Hardware
✓ ✓
Strainers for Water Meters
Plate Strainers 2" to 20" 150 PSIG 120°F FlangedLead Free
Bronze Alloy ✓ ✓ A
Strainers 2" to 12" 175 PSIG 150°F Flanged
Lead Free Bronze/
Epoxy Coated Cast Iron
✓ ✓ A
Strainers1-1/2" to
20"150 PSIG 80°F Flanged
Rilsan Ny-lon-Coated Ductile Iron (Lead Free)
✓ ✓ A
· H=Horizontal Orientation A=Any Position D=Vertical Down U=Vertical Up B=Vertical Up or Down· Threaded meters require couplings of respective size.
877.566.383730
Submetering
Itron Domestic250/400A meterpulsers – 1 Cubic
Foot per Pulse
Riotronics PulsersAdaptable to all
diaphragm metersand Dresser rotary
IMAC Domestic PulserUsed on all small gasdiaphragm meters.
(Itron/American/Sensus)
IMAC PulsimaticUsed on all instrument drive meters includingdiaphragm, rotary and
turbine
T210 Counter workswith all pulse output
meters.
RCM-100 works with allpulse output meters.
Single or Dual Display.
HF-RC works with allpulse output meters.Single or Dual Display
DR3 works with bothpulse and encoder
output meters
ITRON makeswireless modules for
gas (100G), water(100W) and electricmeters. This systemis very popular withmunicipal/military
clients. Meter readscan be read via:
HandheldDrive by
Fixed NetworkSoftware
Inovoics & TehemaInovonics and
Tehema Wirelessmake low poweredwireless systems.
Inovonics works withpulse based meterswhile Tehema workswith either pulse orencoder outputs.
Meter reads can beread via:
Third PartySoftware
Star/Hexagram, nowAclara, offers a high
strength fixed networkwireless system.
Aclara can read bothpulse and encoder
output meters. Meterreads can be read via:
EmailThird PartySoftware
NoWire is a low costsystem for projectswith less than 100metering points. Nospecial software is
required. Works withpulse based metersonly. Meter Readscan be read via:
Local DisplayModbus
CellConnect – WebThird PartySoftware
Submetering EquipmentSubmetering equipment generally consists of the items needed to remotely read meters including pulse output modules, remote counters, and wireless reading systems. For information on specific gas or water meters refer to other pages of this brochure.
Gas Meter Pulse Output Modules
Remote Counters
Wireless Reading Systems
www.mvandc.com 31
Products/Manufacturers
Product ManufacturerActuated Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MaxonAMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Itron/AclaraAutomatic Gas Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BasoBalancing Valves . . . . . . . . . . . . . . . . . . . . . . . . .FlowGuard/Flow DesignBall Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Apollo/Jomar/NibcoBall Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sharpe/Smith - CooperBTU Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cadillac/Istec/OniconButterfly Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . JamesburyCatalytic Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ThermcatCathodic Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IMAC/EagleCheck Valves . . . . . . . . . . . . . . . . . . . . . . . . . . Bonney Forge/Check - AllCoalescing Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter Fab/FiniteControllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .EzeioCryogenic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CashcoData Acquisition Servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ObviousEarthquake Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PSP/KosoEarthquake Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Little FirefighterElectric Meters. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Dent/Emon/EZ MeterElectric Meters. . . . . . . . . . . . . . . . . . . . . . . . . . . Intellimeter/Itron/SharkExcess Flow Valves . . . . . . . . . . . . . . . . . . . . . . . Brasscraft/Chem - TecExcess Flow Valves . . . . . . . . . . . . . . . . . . . . . . . . . . Elster/Gas BreakerExcess Flow Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . OmegaFlex/UMACFilters - Coalescing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter Fab/FiniteFilters - Dry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter Fab/PhilpottFire Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .AnsulFlanges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . AnvilFlexible Gas Pipe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Gastite/FlexpipeGas Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Imac SystemsGas Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Safety FirstGas Electronics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eagle ResearchGas Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter Fab/Philpott/FiniteGas Flow Computers . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eagle ResearchGas Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ThermcatGas Leak Detection . . . . . . . . . . . . . . . . . . . . . . . Gas Guardian/MacurcoGas Meters - Diaphragm . . . . . . . . . . . . . . . . . . . . . . Itron/Elster/SensusGas Meters - Solid State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Itron/SickGas Meters - Rotary. . . . . . . . . . . . . . . . . . . . . . . . . Itron/Dresser/RometGas Meters - Turbine . . . . . . . . . . . . . . . . . . . . . . Elster/Sensus/BlancettGas Meters - Turbine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Imac/SponslerGas Meters - Ultrasonic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SickGas Meters - Thermal Mass. . . . . . . . . . . . . . . . . . . .FCI/Fox/Sage/SierraGas Meter Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . Richards/SGSGas Regulators - Service . . . . . . . . . . . . . . . . Itron/Elster/Sensus/BelgasGas Regulators - Trans . . . . . . . . . . . . . . . . . . . . Pietro Fiorentini/FisherGas Regulators - Ventless . . . . . . . . . . . . . . . . . Pietro Fiorentini/MaxitrolGas Regulators - LPG. . . . . . . . . . . . . . . . . . . . . . . Fisher/Marshall/RegoGas Regulators - Air. . . . . . . . . . . . . . . . . . . . . . . . . . . . Marsh BelloframGas Regulators - Process. . . . . . . . . . . . . . . . . . . . . . . . Marsh BelloframGas Regulators - Relief . . . . . . . . . . . . . . . . . . . . . . Pietro Fiorentini (PF)Gas Regulators - Relief . . . . . . . . . . . . . . . . . . . . . . . . . Marsh BelloframGas Regulators - Steam. . . . . . . . . . . . . . . . . . . . . . . . . Marsh BelloframGasket Strainers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ImacInsertion Meters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . OniconInstrument Filters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Imac
Product ManufacturerInsulating Joints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Barlow/ImacInsulating Flange Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ImacMeter Gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ScadametricsMeter Readers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CelloMeter Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FordMonolithic Insulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ImacNeedle Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . .Marsh Bellofram/ImacOrifice Flow Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . Eagle ResearchPilot Operated PRV. . . . . . . . . . . . . . . . . . . . . . . . . .Itron/Pietro FiorentiniPlug Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nordstrom/FlowservePortable Ultrasonic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dynasonics/GEPortable Ultrasonic. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Endress - HauserPressure Gauges . . . . . . . . . . . . . . . . . . . . . . . .Marsh Bellofram/WintersPressure Recorder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eagle ResearchPropane Equipment . . . . . . . . . . . Marsh Bellofram/Marshall/Fisher/RegoPressure Reducing Valve . . . . . . . . . . . . . . . . . . See Gas Regs/WaterPRVProcess Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eagle ResearchPRV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .See Gas Regs/Water PRVPulsers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Imac/RiotronicsRelays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SSIRelief Valves . . . . . . . . . . . . . . . . . . . . . . . . . .PF/Marsh Bellofram/FarrisRemote Counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elster/MarsRotary Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dresser/Itron/RometRTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eagle ResearchSlam Shut Valves. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pietro FiorentiniSmart Manometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MeriamSolenoid Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eagle ResearchSolenoid Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ASCO/MagnitrolSteam . . . . . . . . . . . . . . . . . . . . . . . . . . . . Marsh Bellofram/Spirax SarcoSteam Meters . . . . . . . . . . . . . . . . . . . . . . . . Sierra/Emco/Onicon/VortekStraightening Vanes. . . . . . . . . . . . . . . . . . . . . . . . . . Apollo EngineeringTest Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pete’s PlugsThermal Shutoff. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FirebagTransmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RosemountTransfer Prover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eagle ResearchTrunion Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Jag/MirUltrasonic Meters. . . . . . . . . . . . . . . . . . . . . . . . Flowsick/EESiFlo/FleximUltrasonic Meters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .GE/ProsonicValves - Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . Crane/DHV/HomesteadValves - Gas . . . . . . . . . . . . . . . . . . . . . . . . . Industrial Valco/JamesburyVentless Gas Regs . . . . . . . . . . . . . . . . . . . . . . . Pietro Fiorentini/MaxitrolVolume Corrector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Eagle ResearchWater Meters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Badger/Carlon/DLJWater Meters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Elster/Hersey/IstecWater Meters. . . . . . . . . . . . . . . . . . . . . . . . . . Mastermeter/McCrometerWater Meters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . MTW/Neptune/NiagraWater Meters. . . . . . . . . . . . . . . . . . . . . . . . . Onicon/Seametrics/SensusWater - PRV. . . . . . . . . . . . . . . . . . . . . . . . . WIIKins/Zurn/Cla - Val/WattsWater Shutoff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FloLogicWeld Ball Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KerotestWireless Metering . . . . . . . . . . . . . . . . . . . . . . . . . Aclara/Inovonics/ItronWireless Metering . . . . . . . . . . . . . . . . . . . . . . .NoWire/Obvious/TehemaY - Strainers . . . . . . . . . . . . . . . . . . . . . . . . . . . Marshall Excelsior/Titan
PLEASE NOTE: The images displayed in this catalog are for display purposes only and may not accurately represent the actual item.
Become a Distributor today! Contact us @ 877-566-3837
01
23
45
67
89
1011
22
22
22
22
22
2p
pp
pp
pp
pp
p4
44
44
44
44
44
aa
aa
aa
aa
aa
ab
bb
bb
bb
bb
bc
cc
cc
cc
cc
c8
88
88
88
88
88
DISTRIBUTED BY: Meter, Valve & Control Inc. WBEPhone: 877-566-3837Fax: 925-407-2903Email: [email protected]: mvandc.com1499 Sunnybrook RoadAlamo, CA. 94507
Unit Conversions
Natural Gas (NG)1 Cubic Foot (CF) = 1,000 BTU100 CF = 1 Therm = 100,000 BTU1000 CF = 1 MCF1 MCF = 1 DekathermMMCF = 1,000,000 CFMCFD = 1,000 CF Per DayMMCFD = 1,000,000 CF Per Day1 MBH = 1,000 BTU per Hour1 CFH = 1 MBH = 1,000 BTUH100 CFH = 100 MBH = 100,000 BTUHSpecific Gravity = 0.6
Liquid Propane Gas (LPG)1 CF = 2,500 BTUSpecific Gravity = 1.53CFH (NG) = BTU (LPG) / 1,575CFH (LPG) = CFH (NG) x 0.63 1 Gallon Liquid Propane = 35.97 CF LPG
Pressure1 psi = 27.67 inches water column (“wc)7"wc = 0.25 pound per square inch (psi)14"wc = 0.5 psi
Metric to US Centimeters (cm) x 0.3937 = InchesMeters x 3.281 = FeetMeters x 1.094 = YardsKilometers x 0.6214 = MilesCubic cm x 0.06103 = Cubic InchesCF x 7.4805 = GallonsLiters / 28.316 = Cubic FeetLiters / 3.785 = GallonsKilograms x 2.205 = PoundsGrams / 28.35 = OuncesKPA x 100 = BarsKPA / 0.145 = psiBars / 14.5 = psiDeg Celsius x 1.8 +32 = Deg Fahrenheit