800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor...

26
242 www.emersonct.com 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete family solution – from the compact Series 2120 chassis drive to the powerful Series 2230 MKII and it’s feature rich application specific options. Fincor drives have earned a reputation for reliability and extensive features which put them a step ahead of the competition. These options are standard on MKII drives and available as noted on other drive series. Some of these features include: Isolated Regulator protects internal control circuits from the AC power source, operators and equipment. The control reference input common may be grounded or connected without additional isolation to additional drives or grounded external sources. Isolation eliminates the common condition of line voltage to ground potential being present at the operator station potentiometer. External DC Signal Follower includes isolation and impedance matching circuitry to interface an externally supplied grounded or ungrounded, isolated or nonisolated 0-5 VDC, 0-10 VDC or 4-20 mA DC signal source, with the motor controller reference input. This provides a linear transfer of the external signal to motor speed. AC Line Starting (Auto-Restart) simplifies restart control wiring requirements. Also permits run-stop control of unidirectional models by using an external AC line contactor. Smooth starting capabilities are included. DC Tachometer Feedback provides wider speed range, improved speed regulation with load changes and reduced sensitivity to operating conditions such as line voltage variations, ambient temperature changes, motor field heating and other operating variables. The controller will automatically transfer to counter EMF voltage feedback to prevent run away if the tachometer circuit is disconnected. Tachometers producing 7 to 150 VDC at maximum motor speed may be used. Analog DC Drive 1/6 to 5 hp (115-230 VAC) Non-regen and Regen models Chassis, Bookshelf, NEMA 1, or NEMA 4/12 Tachometer or armature feedback Complete motor solutions 2610 2610 —Conveyor —Rugged —Extruder —Reliable —Mixer —Flexible —Conveyor —Simple TYPICAL APPLICATIONS 2610 Ad t ble Adjustable S d Speed D Drives Ad t ble S d D Contact factory for “Operator Stations” A P P R O V A L I S O 9 0 0 1 : 2 0 0 0

Transcript of 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor...

Page 1: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

242

www.emersonct.com

800-334-3040

Fincor

Fincor DC DrivesFlexible & Powerful Fincor single-phase DC drives provide a complete family solution – from the compact Series 2120 chassis drive to the powerful Series 2230 MKII and it’s feature rich application specific options.

Fincor drives have earned a reputation for reliability and extensive features which put them a step ahead of the competition. These options are standard on MKII drives and available as noted on other drive series. Some of these features include:

• Isolated Regulator protects internal control circuits from the AC power source, operators and equipment. The control reference input common may be grounded or connected without additional isolation to additional drives or grounded external sources. Isolation eliminates the common condition of line voltage to ground potential being present at the operator station potentiometer.

• External DC Signal Follower includes isolation and impedance matching circuitry to interface an externally supplied grounded or ungrounded, isolated or nonisolated 0-5 VDC, 0-10 VDC or 4-20 mA DC signal source, with the motor controller reference input. This provides a linear transfer of the external signal to motor speed.

• AC Line Starting (Auto-Restart) simplifi es restart control wiring requirements. Also permits run-stop control of unidirectional models by using an external AC line contactor. Smooth starting capabilities are included.

• DC Tachometer Feedback provides wider speed range, improved speed regulation with load changes and reduced sensitivity to operating conditions such as line voltage variations, ambient temperature changes, motor fi eld heating and other operating variables. The controller will automatically transfer to counter EMF voltage feedback to prevent run away if the tachometer circuit is disconnected. Tachometers producing 7 to 150 VDC at maximum motor speed may be used.

• Analog DC Drive • 1/6 to 5 hp (115-230 VAC)• Non-regen and Regen models• Chassis, Bookshelf, NEMA 1, or NEMA 4/12• Tachometer or armature feedback• Complete motor solutions

2610

AdjustableSpeedDrives

2610j

ble

AdjustableSpeedDriDrives

jble

Dri

—Conveyor

—Rugged—Extruder

—Reliable

—Mixer

—Flexible

—Conveyor

—Simple

TYPICAL APPLICATIONS

2610

Adt ble

AdjustableS

dSpeedDDrives

Adt ble

SdD

Contact factory for “Operator Stations”

APPROVAL

ISO

9001:2000

Page 2: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

243

www.emersonct.com

800-334-3040

Finc

or

Order String

Cover Configuration: 0 = No Elements, 1 = Run/Stop/Jog/Speed Pot, 2 = Run/Stop/Jog/Fwd/Rev/Speed Pot, 3 = Run/Stop/Jog/Fwd/Rev P.B./Speed

Pot, 7 = Run/Stop/Jog/Manual-Auto Switch/Speed Pot,

Basic Configuration: No Letter = Chassis, P = Enclosed (top cover)

Armature Contactor: No Letter = None, A = Armature Contactor Reversing with DB, B = Unidirectional Armature Contactor with DB

Frame Size (type): 1 = 1/6 - 2 hp, 2 = 1/2 - 5 hp

Drive Series Revision Level: i.e. 2 = 2120, 3 = 2230, 4 = 2240,

1 = Base, 2 = Regen, 3 = Non-Regen, 6 = Non-Regen high end

2 = Single Phase Input Drive Basic Model

2 x x x x x x

CHOOSE NON-REGEN OR REGENERATIVENon-regenerative drives are used when friction or a dynamic brake stopping is adequate. A contactor may be used to achieve reversing operation. Non-regen drives are less expensive than Regen drives when reversing is not required.

Regenerative drives include static reversing and are used when you need four quadrant control or Forward & Reverse operation from a bidirectional control signal (+/- 10 VDC). It will stop the load smoothly and faster than a dynamic brake for fast stop or emergency stop requirements and it will regenerate power to the supply if the load is overhauling (wanting to go faster than the motor set speed).

CHOOSE DRIVE SERIESNow choose the drive series from either Non-regen or Regen product pages. The chart below compares features and horsepower ratings, with the simplest and least expensive drive at the top and highest horsepower range and fl exibility towards the bottom.

Reg

en

era

tive

Series

2120 / 2130

2330 MKII

2610 MKII

2601 / 2602

2230 MKII

2240

Horsepower

No

n-R

eg

en

era

tive Micro Drive / non-isolated

Limited options / speed input

Full Featured / isolated8 options / speed & torque input

Full Featured / isolated16 options / speed & torque in/out

Full Featured / isolated / room for custom optionsspeed & torque input

Full Featured / isolated12 options / speed & torque in/out

Full Featured / isolated / room for custom optionsspeed & torque input

Fincor Single Phase DC Selection Chart

– Option 1 – Option 2 ...

Page 3: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

244

www.emersonct.com

800-334-3040

Fincor 2100

Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor. These drives may provide speed or torque control from a potentiometer or unidirectional (0-10 VDC or 4-20 mA) control signal. Reversing requires a switch or contact closure to initiate the change. Upon the reversing signal, the drive will allow the motor to coast to a stop (or perform a control stop under a decel ramp with control stop option) or utilize a dynamic braking resistor to pull it to a stop before switching the motor leads with a contactor and starting the motor in the opposite direction.

Fincor Series 2100 drives feature compact size and lowest pricing in chassis, NEMA 1 Panel, NEMA 1, or NEMA 12 enclosures. Chassis units are dimensionally interchangeable with many competitive units. They are ideal for the OEM or panel builder who builds a custom system by integrating the drive into an enclosure with special logic or auxiliary control devices. Enclosed units utilize the enclosure as an integral heatsink and are offered as complete self-contained packages ready for wall or machine mounting.

• 1/6 to 3 hp (115 -230V) • Budget Priced • Speed Control • Current Limit • UL Listed (Enclosed) or UL Recognized (chassis, NEMA 1 Panel)

Open Chassis

EnclosedPanel Mount

2123 2121 & 2122

RATINGS: 1/12 TO 3 hp (120-240 VAC)Series 2100 Non-Regenerative DC Drives

ModelMotor

HP 5

Input Output RUN-STOPRUN-STOP,

Reverse

AC Volts Amps DC Volts Amps

Order Code Order Code Arm Field Arm Field

Chassis1, 3

1/6-1/2 120 8.7 90 50/100 5.4 1.0 21211/6-1/2 120 8.7 90 50/100 5.4 1.0

21221/2-1.0 240 8.8 180 100/200 5.5 1.01/6-1.0 120 15 90 50/100 10.5 1.0

212221/2-2.0 240 15.8 180 100/200 11.6 1.01/6-1.0 120 15 90 50/100 10.5 1.0

21231/2-3.0 240 24 180 100/200 16 1.0

Panel Assembly4 1/6-1/2 120 8.7 90 50/100 5.4 1.02131P1 2131P2

1/2-1.0 240 8.8 180 100/200 5.5 1.0

NEMA 1 Enclosed1/6-1/2 120 8.7 90 50/100 5.4 1.0

2131P1E 2131P2E1/2-1.0 240 8.8 180 100/200 5.5 1.0

NEMA 12 Enclosed1/6-1/2 120 8.7 90 50/100 5.4 1.0

2132P1E 2132P2E1/2-1.0 240 8.8 180 100/200 5.5 1.0

(1) Model 2120 units are furnished with a potentiometer rated 5K ohms, 1/2 watt for separate mounting.(2) Requires either option 1761 for 1 hp on 115 VAC and 2 hp on 230 VAC or option 1760 for 3/4 hp on 115 VAC and 1.5 hp on 230 VAC(3) Armature contactor Run-Stop-DB, and contactor reversing and dynamic braking are provided by Options 1001E and 1004E.(4) Panel assembly models do not include an enclosure. They are intended for mounting on a door or other panel surface through an aperture cut into the users NEMA 1 or NEMA 12 enclosure.(5) Units may be easily recalibrated using trimpots for any standard rating within the hp range.

Fincor Series 2120/2130

Fincor Non-Regen Drives

Page 4: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

245

www.emersonct.com

800-334-3040

Finc

or 2

100

Fincor Series 2120/2130 DIMENSIONS

3.00 ” (76.2 mm)

9.00”(228.6 mm)

3.12”(79.25 mm)

Weight (Enclosed)1 lb. .45 kg

ON

OFF

FORWARD

REVERSE

STOP

2130 Enclosed*

*2130 Panel mount has the same dimensions but has no enclosure.

1.87”(48 mm)

Weight (Chassis)1 lb. .45 kg

7”(178 mm)

4.25”(108 mm)

2123 Chassis

1.64”(42 mm)

Weight (Chassis).5 lb. .23 kg

4.25”(108 mm)

3.55”(90 mm)

2121 & 2122Chassis

SPECIFICATIONS: Operating Conditions Horsepower 1/6 thru 3 hp , Trim Pot Selectable

Line Voltage 115-230VAC ±10%, Bi Voltage Input Rated Frequency 50/60Hz ±2%

Enclosure Chassis, NEMA 1 Panel, NEMA 1, NEMA 12

Ambient Temperature 0 – 40°C (32°F - 104°F) (Enclosed)

0 – 55°C (32°F - 131°F) (Chassis)

Altitude 1000m (3,300 ft)

Relative Humidity 95% Non condensing

Overload Capacity 150% for 1 minute (UL Listed Motor Overload Protection) (120% Timing Threshold)

Standard Features Regulator Function Speed Regulated

Power Conversion 2 SCR plus Freewheeling Diode

Field Supply Full Wave

Protection MOV Voltage Transient Suppression High Interrupting Capacity Line Fuse

Speed Regulation Armature or DC Tach Feedback

Control Control Logic Power Common for Maintained Switch

Speed Potentiometer 5K Ohms, ½ Watt

Input Reference 0 – 10Vdc

Speed Regulation 2% with Armature Feedback (95% Load Change) 1% with Tachometer Feedback

Adjustments Maximum Speed 60% – 100% of Motor Base Speed

Minimum Speed 0% – 40% of Motor Base Speed

Current Limit 0 – 150% of Full Load

IR Compensation 0 – 100% Boost

Acceleration/Deceleration 0-4 Seconds

Efficiency Controller (only) 98%

With Motor (typical) 85%

Approvals & Listings UL and cUL

Page 5: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

246

www.emersonct.com

800-334-3040

Fincor 2100

Series 2100 Allowable Option Combinations

Option GroupsUse with Model

Order CodeOption Description

Fact. Install Fld. Install

C) Power Options - Choice of one within this group. 2120 1001E 106409501 Armature Contactor, 2-Pole with Dynamic Braking

2120 1004E 106409601 Armature Contactor, Reversing, with Dynamic Braking

D) Input Signal Option 2120 1749A 106409401 Follower, External Signal

G) External Option 2120 1721 2067109 Knob and Dial Plate Kit

H) Miscellaneous Options — Choice of any or all within this group. 2120 1719 2067114 Fuse Block Kit

2120 1730A 106409701 Barrier Terminal Board (115VAC)

2120 1730B 106409702 Barrier Terminal Board (230VAC)

2120 1731 2067118 Dual Connector Terminal Adapter (for 2120 Tacho F/B)

2120 1760 2067106 Heat Sink Kit (Flat)

2120 1761 2067098 Heat Sink Kit (Radial)

Series 2100 Detailed Option Descriptions

Option Description

1001E Armature Contactor, 2-Pole with Dynamic Braking — The basic Series 2120 chassis controller is designed for Run-Stop unidirectional operation without an armature contactor. This option provides a two-pole armature contactor which is necessary whenever the application requires a positive disconnection of the rectifi ed armature power source from the motor on a stop command. Action of the contactor is sequenced with the SCR regulator to ensure that the DC power circuit is “phased-off” before the contactor is opened. This results in “Dry switching” for improved contactor longevity. This option also includes dynamic braking which provides exponential rate braking of the DC motor armature. Included is a DB resistor with an anti-plug circuit to prevent restarting the controller until the braking cycle is complete, thereby preventing a potentially damaging electrical surge and mechanical stress. This option permits motor Start/Stop operation by pushbuttons or external logic in 115 or 230 VAC applications. The DB resistor is rated for stopping a typical load, when the external machine inertia does not exceed that of the motor armature, as shown in the table.

1004E Armature Contactor, Reversing, with Dynamic Braking — This option is the same as Option 1001E except two double pole contactors are provided for reversing the DC motor armature rated 1 hp at 90 VDC armature or 3 hp at 180 VDC maximum. Anti-plug protection is provided to prevent armature reversal until a safe minimum speed is attained. The direction of motor rotation is controlled by external RUN/FORWARD-REVERSE pushbuttons, switches or logic. Braking times are same as option 1001E above.

1719 Fuse Block Kit — Kit includes a fuse block, lead wire with spade connectors, and mounting screw. The option provides external line fuse protection for Series 2120 chassis controllers (fuse not included).

1721 Knob and Dial Plate Kit — This option provides a knob and a dial face graduated 0-100% for use with the potentiometer provided with Series 2120 units.

1730A Barrier Terminal Board — 115VAC Kit includes screw terminals for all external wiring, one line fuse holder, and an LED power on indicator in an assembly that plugs piggy-back onto chassis model units. (fuse not included).

1730B Barrier Terminal Board — 230VAC Kit includes screw terminals for all external wiring, one line fuse holder, and an LED power on indicator in an assembly that plugs piggy-back onto chassis model units. (fuse not included).

1731 Dual Connector Terminal Adapter — This option provides a two (male) into one (female) push-on terminal to facilitate connection of Series 2120 units for tachometer feedback and/or inhibit.

1749A Follower, External signal — This option is intended as a low cost alternative which offers greater accuracy and fl exibility. Option 1749A is capable of operating from the following isolated or nonisolated signals: 4-20 DC ma, 0-10 VDC. This option includes a scaling potentiometer for offset adjustment. Dimensions 1.5” (38) X 3.38” (86) X .75” (19).

1760 Heatsink Kit (Flat) — This option consists of an extruded aluminum heatsink and hardware to mount a Model 2122 controller. This heatsink is intended for use only with Model 2122 where its greater heat dissipation permits increasing the units original rated horsepower. Option includes special white silicone grease compound to improve heat transfer. Dimensions: 4.4375” (113) X 6.75” (171) X .875” (22).

1761 Heatsink Kit (Radial) — This option consists of a unique space saving radial design heatsink and hardware to mount to a Model 2122 controller. This heatsink is intended for use only with Model 2122 where it’s greater heat dissipation permits a greater horsepower rating than when using the 1760 Flat Heatsink Kit. Option includes special white silicon grease compound to improve heat transfer. Dimensions: 2” (51) X 1.375” (35) X 4.25” (108).

Page 6: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

247

www.emersonct.com

800-334-3040

Finc

or 2

330

Fincor Series 2330 MKIIFincor Series 2330 MKII drives features a fully isolated regulator using surface mount technology. It includes an isolated customer run contact, low voltage operator control circuitry, and full wave power conversion.

Enclosed

Open Chassis

Book Case

• 1/6 to 5 hp (115-230V)• Fully Isolated Regulator• Speed or Torque Control• 0-10 VDC or 4-20 mA input signal• Fused Input• Line Start (Auto Restart)• Dual Field Supply• Tachometer Input standard

RATINGS: 1/6 TO 5 hp (115-230 VAC)Series 2330 MKII Non-Regenerative DC Drives

ModelMotor

HP

Input OutputRun-Stop,

(Basic)

Run-Stop, Arm. Cont.

DB

Run-Stop, Arm. Cont., Rev. & DB

AC Volts Amps DC Volts Amps

Order Code Order Code Order Code Arm Field Arm Field

Chassisw/o Operator

Controls

1/6-1.0 120 15.8 90 50/100 10.5 1.02331 2331B 2331A

1/2-2.0 240 15.8 180 100/200 11.6 1.0

1/6-1.0 120 15.8 90 50/100 10.5 1.02332 2332B 2332A

1/2-3.0 240 22 180 100/200 15.1 1.0

Book Case w/o Operator

Controls

1/6-1.0 120 15.8 90 50/100 10.5 1.02335 2235B 2235A

1/2-2.0 240 15.8 180 100/200 11.6 1.0

1/6-1.0 120 15.8 90 50/100 10.5 1.02336 2336B 2336A

1/2-3.0 240 22 180 100/200 15.1 1.0

1/6-1.0 120 15.8 90 50/100 10.5 1.02337

1/2-5.0 240 32 180 100/200 25 2.0

NEMA 4/12 w/o Operator Controls

1/6-1.0 120 15.8 90 50/100 10.5 1.02331P0 2331BP0 2331AP0

1/2-2.0 240 15.8 180 100/200 11.6 1.0

NEMA 4/12 with Integral Operator

Controls

1/6-1.0 120 15.8 90 50/100 10.5 1.02331P1* 2331BP1* 2331AP3

1/2-2.0 240 15.8 180 100/200 11.6 1.0

1/6-1.0 120 15.8 90 50/100 10.5 1.02331P2*

1/2-2.0 240 15.8 180 100/200 11.6 1.0

Units shipped calibrated for desired hp rating but jumpers can be adjusted for others. Units shipped ready for 230VAC but may be reconnected for 115VAC.

* P1, PB1, & PB2 have additional Jog controls.

Page 7: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

248

www.emersonct.com

800-334-3040

Fincor 2330

Fincor Series 2330 MKIIDIMENSIONS

RUN

JOGSTOP

FWD

REV

5”(127 mm)

9.5”(231 mm)

5.25”(133 mm)

Weight (Enclosed)3 lbs. 1.56 kg

2330

Adjustable

AdjustableSpeedSpeedDrivesDrives

AdjustableSpeedDrives

MOTOR SPEED (%)

5”(127 mm)

9.5”(241 mm)

4.25”(108 mm)

Weight (Chassis)3 lbs. 1.36 kg

2330

1.75”(43 mm)

8.85”(218 mm)

4.25”(108 mm)

Weight (Bookcase)1 lb. .45 kg

2330 MKII Enclosed

2330 MKII Chassis2330 MKII

Bookcase

SPECIFICATIONS: Operating Conditions Horsepower 1/6 thru 5 hp, Jumper Selectable

Line Voltage 115-230VAC ±10%, Jumper Selectable

Rated Frequency 50/60Hz ±2%

Enclosure Chassis, Bookcase, NEMA 4/12

Ambient Temperature 0 – 40°C (32°F - 104°F) (Enclosed)

0 – 55°C (32°F - 131°F) (Chassis)

Altitude 1000m (3,300 ft)

Relative Humidity 95% Non condensing

Overload Capacity 150% for 1 minute (UL Listed Motor Overload Protection) (120% Timing Threshold)

Standard Features Isolated Regulator Circuit Grounded I/O signals possible Regulator Function Speed or Torque selectable

Power Conversion 4 SCR plus Freewheeling Diode

Field Supply Full or Half Wave

Protection MOV Voltage Transient Suppression High Interrupting Capacity Line Fuse

Speed Regulation Armature or DC Tach Feedback

Line Start Selectable for Auto Restart

Diagnostic LED Green Normal – Red Current Limit

Option Connector Connects Additional Option Boards

Control Control Logic Power 24VDC for Maintained Switch or Pushbutton Operation

Speed Potentiometer 5K Ohms, ½ Watt

Input Reference 0 – 10Vdc or 4 – 20ma

Speed Regulation 2% with Armature Feedback (95% Load Change) 0.5% with Tachometer Feedback

Adjustments Maximum Speed 50% – 100% of Motor Base Speed

Minimum Speed 0% – 40% of Motor Base Speed

Current Limit 0 – 150% of Full Load

IR Compensation 0 – 100% Boost

Acceleration/Deceleration 0.2-30 Seconds

Efficiency Controller (only) 98%

With Motor (typical) 85%

Approvals & Listings UL and cUL

Page 8: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

249

www.emersonct.com

800-334-3040

Finc

or 2

330

Minimum Speed

+10V RefExt Current Ref Input

Circuit Common

Tachometer Fdbk InputRun Enable Input (+24VDC)

+24VDCRun Relay N.O. ContactsRun Relay N.O. Contacts

Current Loop Follower Input

Speed Ref Input

Motor Armature

Speed Ref Pot

Torque Ref Pot

4-20ma

HalfWaveField

TERMINAL DIAGRAM: 2330 MKII

TERMINAL DESCRIPTION

Pin# Type Notes

L1 Line Voltage Input 115 or 230VAC J1 Selectable

L2 Line Voltage Input 115 or 230VAC J1 Selectable

F+ Field Voltage Output +100VDC @ 115VAC or +200VDC @230VAC Input

F/2 Field Voltage (Half-Wave) Output

+50VDC @ 115VAC or +100VDC @230VAC Input

F- Field Voltage Output Field Minus Output

A1 Armature + Output 0 to +90VDC @ 115VAC or 0 to +180VDC @ 230VAC Input

A2 Armature - Output Armature Minus Output

TB1Pin# Type Notes

1 Speed Reference Pot ‘0’ End With On-board Min Speed Pot Active

2 Speed Reference Input 200KΩ Input Resistance

3 +10V Reference Output 5ma max

4 External Current Reference Input FWD

Refer to DIP Switch SW3-

5 Circuit Common Isolated From Line – Can be connected to Earth

6 Current Loop Follower Input Refer to DIP Switch SW3-2 (1-5, 4-20, 5-50ma)

7 Tachometer Input (Speed Feedback)

Polarity Insensitive for Reversing Applications (3-30Vdc, 31-175Vdc)

8 Enable Input (+24VDC) – Run Relay

24VDC @ 6ma Input

9 +24VDC For drive enable use only

10 Run Relay N.O. Contacts Form A Contact Rated 0.5A @ 115VAC or 2A @ 30VDC11 Run Relay N.O. Contacts

TB2

TB1 TB2

Page 9: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

250

www.emersonct.com

800-334-3040

Fincor 2600

2610 MKII Enclosed Fincor Series 2600 / 2610 MKII drives feature a fully isolated regulator and numerous options. Series 2610 MKII has new and improved board design with more standard features to 3 hp while the larger Series 2600 offers ratings to 5 hp and additional space for internally mounted options.

RATINGS: 1/6 TO 5 hp (115-230 VAC)

Series 2600/2610 MKII Non-Regenerative DC DrivesModel Motor

HPInput Output

Run-Stop, (Basic)

Run-Stop, Arm. Cont.

DB

Run-Stop, Arm. Cont., Rev. & DB

AC Volts Amps DC Volts Amps Order Code Order Code Order Code Arm Field Arm Field

Chassis

1/6-1.0 115 15.8 90 50/100 10.5 1.0 2611 2611B 2611A1/2-2.0 230 15.8 180 100/200 11.6 1.01/6-1.0 115 15.8 90 50/100 10.5 1.0 2612 2612B 2612A1/2-3.0 230 22 180 100/200 15.1 1.51/6-1.0 115 15.8 90 50/100 10.5 1.0 2601 2601B 2601A1/2-3.0 230 22 180 100/200 15.1 1.51/6-1.0 115 15.8 90 50/100 10.5 1.0 2602 2602B 2602A1/2 -5.0 230 32 180 100/200 25 2.0

NEMA 4/12 w/o Integral Operator

Controls

1/6-1.0 115 15.8 90 50/100 10.5 1.0 2611P0 2611BP0 2611AP01/2-2.0 230 15.8 180 100/200 11.6 1.01/6-1.0 115 15.8 90 50/100 10.5 1.0 2601P0 2611BP0 2611AP01/2-3.0 230 22 180 100/200 15.1 1.51/6-1.0 115 15.8 90 50/100 10.5 1.0 2602P0 2602BP0 2602AP01/2-5.0 230 32 180 100/200 25 2.0

NEMA 4/12 with Integral Operator

Controls

1/6-1.0 115 15.8 90 50/100 10.5 1.0 2611P1* 2611BP1 2611AP3*1/2-2.0 230 15.8 180 100/200 10.5 1.01/6-1.0 115 15.8 90 50/100 10.5 1.0 2601P1 2601BP1 2601AP3*1/2-2.0 230 15.8 180 100/200 11.6 1.01/6-1.0 115 15.8 90 50/100 10.5 1.0 2602P1* 2602BP1 2602AP3*1/2-5.0 230 32 180 100/200 25 2.01/6-1.0 115 15.8 90 50/100 10.5 1.0 2611P21/2-2.0 230 15.8 180 100/200 11.6 1.01/6-1.0 115 15.8 90 50/100 10.5 1.0 2611P7 2611BP7 Manual / Auto

Switch, Used for automatic control by an

external signal, not compatible with tach follower.

1/2-3.0 230 22 180 100/200 15.1 1.51/6-1.0 115 15.8 90 50/100 10.5 1.0 2601P7 2601BP71/2-3.0 230 22 180 100/200 15.1 1.51/6-1.0 115 15.8 90 50/100 10.5 1.0

2602P7 2602BP71/2-5.0 230 32 180 100/200 25 2.0

Units shipped calibrated for desired hp rating but jumpers can be adjusted for others. Units shipped ready for 230VAC but may be reconnected for 115VAC. * Has additional Jog control.

Fincor Series 2600/2610 MKII

FINCOR 2600/2610 MKII • Speed or Torque Control • 0-10 VDC or 4-20 mA input signal • Line Start (Auto Restart) • Dual Field Supply • Tachometer Input standard

FINCOR 2610 MKII SPECIFIC • 1/12 to 2 hp (3 hp in chassis) • Fully Isolated Regulator • PID / Speed Trim Control • Monitoring Output (0-10 VDC or 4-20 mA)

FINCOR 2600 SPECIFIC • 1/6 to 5 hp (115-230V)

Open Chassis Book Case

2600 Enclosed

Page 10: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

251

www.emersonct.com

800-334-3040

Finc

or 2

600

DIMENSIONSFincor Series 2600

2600 Chassis

9”(228 mm)

12.1”(307 mm)

8.6”(218 mm)

Weight (Enclosed)13.2 lbs. 5.99 kg

RUN

JOGSTOP

Adjustable

AdjustableSpeedSpeedDrivesDrives

AdjustableSpeedDrives

MOTOR SPEED (%)

9”(228 mm)

12.1”(307 mm)

8.6”(218 mm)

Weight (Enclosed)13.2 lbs. 5.99 kg

2600Enclosed

SPECIFICATIONS: Operating Conditions Horsepower 1/6 thru 5 hp, Clip-out Shunt Wires

Line Voltage 115-230VAC ±10%

Rated Frequency 50/60Hz ±2%

Enclosure Chassis, NEMA 4/12

Ambient Temperature 0 – 40°C (32°F - 104°F) (Enclosed)

0 – 55°C (32°F - 131°F) (Chassis)

Altitude 1000m (3,300 ft)

Relative Humidity 95% Non condensing

Overload Capacity 150% for 1 minute (UL Listed Motor Overload Protection – File # E184521) (120% Timing Threshold)

Standard Features Regulator Function Speed or Torque selectable

Power Conversion 4 SCR plus Freewheeling Diode

Field Supply Full or Half Wave Protection MOV Voltage Transient Suppression High Interrupting Capacity Line Fuse

Speed Regulation Armature or DC Tach Feedback

Line Start Selectable for Auto-Restart

Zero Speed Deadband Selectable 2% or Off

Option Connector Connects Additional Option Boards

Control Control Logic Power 24VDC for Maintained Switch or Pushbutton Operation Speed Potentiometer 5K Ohms, ½ Watt

Input Reference 0 – 10Vdc or -10 – +10Vdc Speed Regulation 2% with Armature Feedback (95% Load Change) 0.5% with Tachometer Feedback Adjustments Maximum Speed 50% – 100% of Motor Base Speed

Current Limit FWD 0% – 150% of Full Load Current Limit REV 0% – 150% of Full Load

IR Comp/Tach Scaling 0 – 10% IR or 0 – 100% Tach

Acceleration/Deceleration 0.2 – 30 Seconds

Efficiency Controller (only) 98%

With Motor (typical) 85%

Approvals & Listings UL and cUL

Page 11: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

252

www.emersonct.com

800-334-3040

Fincor 2600

DIMENSIONSFincor Series 2610

2610 MKII Enclosed

2610 MKIIChassis

RUN

JOGSTOP

5”(127 mm)

9.5”(241 mm)

5.25”(133 mm)

Weight (Enclosed)3.25 lbs. 1.48 kg

2610

Adjustable

AdjustableSpeedSpeedDrivesDrives

AdjustableSpeedDrives

MOTOR SPEED (%)

5”(127 mm)

9.5”(241 mm)

4.25”(108 mm)

Weight (Chassis)3 lbs. 1.36 kg

2610

1.75”(43 mm)

8.85”(218 mm)

4.25”(108 mm)

Weight (Bookcase)1 lb. .45 kg

2615 MKIIBookcase

SPECIFICATIONS: Operating Conditions Horsepower 1/6 thru 3 hp, Jumper Selectable

Line Voltage 115-230VAC ±10%, Jumper Selectable

Rated Frequency 50/60Hz ±2%

Enclosure Chassis, Bookcase, NEMA 4/12

Ambient Temperature 0 – 40°C (32°F - 104°F) (Enclosed)

0 – 55°C (32°F - 131°F) (Chassis)

Altitude 1000m (3,300 ft)

Relative Humidity 95% Non condensing

Overload Capacity 150% for 1 minute (UL Listed Motor Overload Protection – File # E184521) (120% Timing Threshold)

Standard Features Isolated Regulator Function Grounded I/O signals possible

Regulator Function Speed or Torque selectable

Power Conversion 4 SCR plus Freewheeling Diode

Field Supply Full or Half Wave Protection MOV Voltage Transient Suppression High Interrupting Capacity Line Fuse

Speed Regulation Armature or DC Tach Feedback

Line Start Selectable for Auto-Restart

Controlled Stop Provides ramp to stop function

Zero Speed Indication Open Collector – Active Low

Speed Regulation Node External PID Input or Speed Trim

Speed Outputs 0 – 10Vdc and 4 – 20ma

Torque Outputs 0 – 10Vdc and 4 – 20ma

Diagnostic LED Green Normal – Red Current Limit

Option Connector Connects Additional Option Boards

Control Control Logic Power 24VDC for Maintained Switch or Pushbutton Operation Speed Potentiometer 5K Ohms, ½ Watt

Input Reference 0 – 10Vdc or -10 – +10Vdc Speed Regulation 2% with Armature Feedback (95% Load Change) 0.5% with Tachometer Feedback Adjustments Maximum Speed 50% – 100% of Motor Base Speed

Minimum Speed 50% – 40% of Motor Base Speed Current Torque Limit 0% – 150% of Full Load

IR Compensation 0 – 10% Boost

Acceleration/Deceleration 0.1 – 30 Seconds Voltage (Speed) Stability Speed Gain Fine Tune Current (Torque) Stability Current Gain Fine Tune

Efficiency Controller (only) 98%

With Motor (typical) 85%

Approvals & Listings UL and cUL

Page 12: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

253

www.emersonct.com

800-334-3040

Finc

or 2

600

Min Speed

+10V RefExt Current Ref Input

Current Common

Tachometer Fdbk InputRun Enable Input (+24VDC)

+24VDCRun Relay N.O. ContactsRun Relay N.O. Contacts

Controlled Stop Input

Speed Reg Node InputCur. (4 to 20mA) Output Speed

Circuit Common0 to +10VDC Output Speed

Zero Speed Output

Current Loop Follower Input

Speed Ref Input

Circuit Common

Circuit Common0 to +10VDC Output Torque

Circuit Common

Cur. (4 to 20mA) Output Torque

Speed Ref Pot

Torque Ref Pot

K

Controlled Stop

HalfWaveField

Motor Armature

4-20ma

TERMINAL DIAGRAM: 2600/2610 MKII

TERMINAL DESCRIPTION

Pin# Type Notes

L1 Line Voltage Input 115 or 230VAC J1 Selectable

L2 Line Voltage Input 115 or 230VAC J1 Selectable

F+ Field Voltage Output +100VDC @ 115VAC or +200VDC @230VAC Input

F/2 Field Voltage (Half-Wave) Output

+50VDC @ 115VAC or +100VDC @230VAC Input

F- Field Voltage Output Field Minus Output

A1 Armature + Output 0 to +90VDC @ 115VAC or 0 to +180VDC @ 230VAC Input

A2 Armature - Output Armature Minus Output

TB1 TB2

TB1

Pin# Type Notes

8 Enable Input (+24VDC) – Run Relay

24VDC @ 6ma Input

9 +24VDC For drive enable use only

10 Run Relay N.O. Contacts Form A Contact Rated 0.5A @ 115VAC or 2A @ 30VDC11 Run Relay N.O. Contacts

12 Controlled Stop Input (+24VDC)

Momentary +24VDC Input to Initiate Controlled (Ramp) to Stop

13 Zero Speed Indication Output Open Collector, Active Low, Rated 24VDC @ 50ma

14 Speed Regulator Node Input Speed Trim or External PID Input (Bypasses Accel/Decel Ramps)

15 Current Loop Output 4 to 20ma – Speed (Arm Volts)

16 Current Loop Output 4 to 20ma – Speed (Arm Volts)

17 Voltage Output 0 to 10VDC – Speed (Arm Volts)

18 Voltage Output Common Isolated From Line – Can be connected to Earth

19 Current Loop Output 4 to 20ma – Torque (Arm Amps)20 Current Loop

21 Voltage Output 0 to 10VDC – Load (Arm Amps)

22 Voltage Output Common Isolated From Line – Can be connected to Earth

TB2Pin# Type Notes

1 Speed Reference Pot ‘0’ End With On-board Min Speed Pot Active

2 Speed Reference Input 200KΩ Input Resistance

3 +10V Reference Output 5ma max

4 External Current Reference Input

Refer to DIP Switch SW3-2 (1-5, 4-20, 5-50ma)

5 Circuit Common Isolated From Line – Can be connected to Earth

6 Current Loop Follower Input Refer to DIP Switch SW3-2 (1-5, 4-20, 5-50ma)

7 Tachometer Input (Speed Feedback)

Polarity Insensitive for Reversing Ap-plications (3-30VDC, 31-175VDC)

TB2 Continued

Page 13: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

254

www.emersonct.com

800-334-3040

Fincor 2600

Series 2600 & 2610 MKII Options with Allowable Combinations

Option Groups Use with Model

Order Code Option Code

Option description

Fact. Install Fld. InstallA) Enclosure Options — Choice of any or all within this group. Option 1170A is required whenever Model 2602 is operated at a 5 hp rating as an enclosed unit.

2601, 2602 1170A 106151401 XK Fan Assembly (5 hp only)2601, 2602 1638 105567001 XK Hinge, Enclosure Cover

B) Options Used To Convert Open Chassis Units into Enclosed Package Controllers — Choice of one within this group.

2610 1639 106116204 XK Cover Assembly, Blank Type “P0”2610 1639C 106116201 XK Cover Assembly, Type “P1”2610 1639E 106116202 XK Cover Assembly, Type “P2”2610 1639G 106116203 XK Cover Assembly, Type “P3”

2601, 2602 1639 106108604 XK Cover Assembly, Blank Type “P0”2601, 2602 1639C 106108601 XK Cover Assembly, Type “P1”2601, 2602 1639G 106108603 XK Cover Assembly, Type “P3”

C) Power Options 2611 1001(2 hp) 106242801 XK Armature Contactor, Unidirectional With DB (2 hp)2601, 2612 1001(3 hp) 106242802 XK Armature Contactor, Unidirectional With DB (3 hp)

2602 1001(5 hp) 106242803 XK Armature Contactor, Unidirectional With DB (5 hp)2611 1004(2 hp) 106154301 XK Armature Contactor, Reversing With DB (2 hp)

2601, 2612 1004(3 hp) 106154302 XK Armature Contactor, Reversing With DB (3 hp)2601 1010(3 hp) 105535403 XK Circuit Breaker 2-Pole (3 hp)2602 1010(5 hp) 105535404 XK Circuit Breaker 2-Pole (5 hp)

D) Signal Options 2601, 2602 1049*1 2660165 XK, P Follower, External DC SignalAny 1050*1 2660170 XK, P Follower, External AC SignalAny 1050A*1 1043525 XK, P Follower, AC Current TransducerAny 1055*1 2550163 XK, P Follower, AC or DC Tachometer GeneratorAny 1057A*1 2660270 XK, P Follower, Digital Pulse Generator

2601, 2602 1059*1 104696301 XK, P Reference, Precision2611, 2612 1059A 104438501 XK, P External DC Power Supply (4-20mA Signal Output)

Any 1775*1 106155801 XK Interface, Signal Options (Pre-requisite)E) Feedback Options — Choice of one within this group. Can be combined with options from all groups except Group F. Option 1775 is a prerequi-site for all options in this group.

2601, 2602 1061C*1 104736301 XK, P AC or DC Tach FeedbackAny 1062A*1 2660269 XK, P Feedback, Digital Pulse GeneratorAny 1190 2660164 XK Torque Taper

F) Input and Feedback Options — Choice of one within this group. Can be combined with options from all groups except Groups D and E.

2601, 2602 1037 104309601 XK, P Input/Feedback Adapter Interface BoardAny 1190 2660164 XK Torque TaperAny 1220 104406401 XK Constant Velocity Winder

G) External Options — Choice of any or all within this group.

Any 1022 Jog, Toggle Switch Selection2601, 2602 1037A 104309501 XK, P Input/Feedback Adapter 1-Position2601, 2602 1037B 104311201 XK, P Input/Feedback Adapter 2-Position

Any 1058A 104195209 K Follower/Manual Mode Selector Switch (SCS168)Any 1120A 2660168 K Motor Speed Potentiometer, Ten-Turn With Analog

DialAny 1120B 104192505 K Motor Speed Potentiometer, One-TurnAny 1120C 104319401 K Motor Speed Potentiometer, Ten-Turn With Digital DialAny 1166 BOOK-0795 K Extra Equipment Manuals

H) Miscellaneous Options — Choice of any or all within this group.

2600 10152 106456601 XK Magnetic Control Interface 115VAny 1081B3 106343221 XK Current (Torque) Monitor

2601, 2602 1072A4 2660271 XK Aux. Contacts (2 Form C)

Notes:* This option requires Option 1775 interface

XK–Factory or Field Kit, K–Field Kit, P–Plug-In Option

1) Option 1775 is a prerequisite to enable the use of all options market *. Option 1775 mounts within the chassis of Models 2601 or 2602. Option 1775 may also be used with Models 2611 and 2612 but must be mounted external to these units.(2) Bidirectional requires quantity of 2.(3) Not compatible with tachometer feedback(4) This option can only be used with the 2601 and 2602 if it is to be mounted in the controller enclosure. This option requires the controller to have the contactor board as well. Not offered in any other confi guration.

Page 14: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

255

www.emersonct.com

800-334-3040

Finc

or

Fincor Regenerative DC Drives Regenerative adjustable speed drives also known as four-quadrant drives, are capable of controlling not only the speed and direction of motor rotation, but also the direction of motor torque. This is illustrated below.

The term regenerative describes the ability of the drive under braking conditions to convert the mechanical energy of the motor and connected load into electrical energy which is returned (or regenerated) to the AC power source.

When the drive is operating in Quadrants I & III, both motor rotation and torque are in the same direction and it functions as a conventional non-regenerative drive. The unique characteristics of a regenerative drive are apparent in Quadrants II & IV. In these quadrants, the motor torque opposes the direction of motor rotation which provides a controlled braking or retarding force. A high performance regenerative drive, such as the Series 2230, is able to switch rapidly from motoring to braking modes while simultaneously controlling the direction of motor rotation.

MOTOR ROTATION

TORQUE

NOTE:

QUADRANT I

QUADRANT III

QUADRANT II

QUADRANT IV

ARROWSSAME DIRECTION

MOTORING (PULLING)

ARROWSOPPOSITE DIRECTIONBRAKING (HOLDING)

—Material Payoff

—Performance

—Conveyor

—Reliable

TYPICAL APPLICATIONS

RUN

JOGSTOP

Adjustable

AdjustableSpeedSpeedDrivesDrives

AdjustableSpeedDrives

MOTOR SPEED (%)

RUN

JOGSTOP

2610

Adjustable

AdjustableSpeedSpeedDrivesDrives

AdjustableSpeedDrives

MOTOR SPEED (%)

Regenerative drives provide reversing without the use of a contactor. This reduces system cost while eliminating moving parts and greatly improving reversing and braking performance.

Although the regenerative drive eliminates the requirement of a contactor for reversing or normal operational braking, a contactor is used if dynamic braking is still required. Although regenerative braking stops the motor and it’s load faster under normal conditions, a dynamic brake may be required to stop the motor and it’s connected load in emergency stop conditions such as drive failure or if the drive enable is removed before the motor comes to a complete stop.

Page 15: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

256

www.emersonct.com

800-334-3040

Fincor 2200

Fincor Series 2200 regenerative drives are ideal for your more demanding applications. They feature flexibility with ratings up to 5 horsepower. The Series 2230 MKII offers new and improved board design with more standard features to 3 hp while the larger Series 2240 offers ratings to 5 hp and additional space for internally mounted options.

2240 Enclosed

Open Chassis Book Case

2230 MKII Enclosed

Fincor Series 2230 MKII/2240

FINCOR SERIES 2230 MKII / 2240 • Speed or Torque Control • 0-10 VDC or +/- 10 VDC input signal • Current Stability Adjust • PID / Speed Trim Control • Fused Input • Line Start / Auto Restart Enable / Disable • Dual Field Supply • Tachometer Input standard • Monitoring Output (0-10 VDC or 4-20 mA) • Diagnostic LED

FINCOR SERIES 2230 MKII SPECIFIC • 1/6 to 3 hp (115-230V) • Fully Isolated Regulator • Speed or Current Monitoring (0-10 VDC or 4-20 mA) • Surface mount technology circuit board

FINCOR SERIES 2240 SPECIFIC • 1/6 to 5 hp (115-230V) • Motor contactor option mounts inside enclosure

RATINGS: 1/6 TO 5 hp (115-230 VAC)Series 2200 Regenerative DC Drives

Model MotorHP

Input Output Run-Stop, Static *

Run-Stop, DB **

AC Volts Amps DC Volts Amps Order Code Order Code

Arm Field Arm Field

Chassis w/o Integral Operator Controls

1/6 - 1.0 120 15.8 90 50/100 10.5 1.0 2231 2231B1/2 - 2.0 240 15.8 180 100/200 11.6 1.01/6 - 1.0 120 15.8 90 50/100 10.5 1.0 2232 2232B1/2 - 3.0 240 22 180 100/200 11.6 1.01/6 - 1.0 120 15.8 90 50/100 10.5 1.0 2242 2242B1/2 - 5.0 240 32 180 100/200 25 2.0

Book Case w/o Integral Operator

Controls

1/6 - 1.0 120 15.8 90 50/100 10.5 1.0 2235 2235B1/2 - 2.0 240 15.8 180 100/200 11.6 1.01/6 - 1.0 120 15.8 90 50/100 10.5 1.0

2236 2236B1/2 - 3.0 240 22 180 100/200 15.1 1.0

NEMA 4/12 w/o Operator Controls

1/6 - 1.0 120 15.8 90 50/100 10.5 1.0 2231P0 2231BP01/2 - 2.0 240 15.8 180 100/200 11.6 1.01/6 - 1.0 120 15.8 90 50/100 10.5 1.0 2242P0 2242BP01/2 - 5.0 240 32 180 100/200 25 2.0

NEMA 4/12 with Integral Operator

Controls

1/6 - 1.0 120 15.8 90 50/100 10.5 1.0 2231P1 2231BP11/2 - 2.0 240 15.8 180 100/200 11.6 1.01/6 - 1.0 120 15.8 90 50/100 10.5 1.0 2242P1 2242BP11/2 - 5.0 240 32 180 100/200 25 2.0

Units shipped calibrated for desired hp rating but jumpers can be adjusted for others. Units shipped ready for 230VAC but may be reconnected for 115VAC.

* RUN-STOP, Static, Contactorless Control ** RUN-STOP / DB, Armature Contactor Control & Dynamic Braking

Page 16: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

257

www.emersonct.com

800-334-3040

Finc

or 2

200

Fincor Series 2230 MKII DIMENSIONS

2230 MKII Enclosure

2230 MKII Bookcase

2230 MKII Chassis

RUN

JOGSTOP

5”(127 mm)

9.5”(241 mm)

5.25”(133 mm)

Weight (Enclosed)3 lbs. 1.36 kg

2230

Adjustable

AdjustableSpeedSpeedDrivesDrives

AdjustableSpeedDrives

MOTOR SPEED (%)

5”(127 mm)

9.5”(241 mm)

4.25”(108 mm)

Weight (Chassis)3 lbs. 1.36 kg

2230

1.75”(43 mm)

8.85”(218 mm)

4.25”(108 mm)

Weight (Bookcase)1 lb. .45 kg

SPECIFICATIONS: Operating Conditions Horsepower 1/6 thru 3 hp, Jumper Selectable Line Voltage 115-230VAC ±10%, Jumper Selectable Enclosure Chassis, Bookcase, NEMA 4/12 Rated Frequency 50/60Hz ±2% Selectable Ambient Temperature 0 – 40°C (32°F - 104°F) (Enclosed) 0 – 55°C (32°F - 131°F) (Chassis) Altitude 1000m (3,300 ft) Relative Humidity 95% Non condensing Overload Capacity 150% for 1 minute (UL Listed Motor Overload Protection – File # E184521) (120% Timing Threshold)

Standard Features Isolated Regulator Circuit Grounded I/O signals possible Regulator Function Speed or Torque selectable Power Conversion 8 SCR Full Wave - Four Quadrant Field Supply Full Wave Protection MOV Voltage Transient Suppression High Interrupting Capacity Line Fuse Speed Regulation Armature or DC Tach Feedback Line Start Selectable for Auto-Restart Controlled Stop Provides Ramp to Stop Function Zero Speed Deadband Selectable 2% or Off Zero Speed Indication Open Collector – Active Low Direction Indication Open Collector – Active Low = FWD Speed Regulator Node External PID Input or Speed Trim Speed Outputs -10 – 10Vdc and 4 – 20ma Torque Outputs -10 – 10Vdc and 4 – 20ma Diagnostic LED Green Normal – Red Current Limit

Option Connector Connects Additional Option Boards

Control Control Logic Power 24VDC for Maintained Switch or Pushbutton Operation Speed Potentiometer 5K Ohms, ½ Watt Input Reference 0 – 10Vdc or -10 – +10Vdc Speed Regulation 2% with Armature Feedback

(95% Load Change) 0.5% with Tachometer Feedback

Adjustments Maximum Speed 50% – 100% of Motor Base Speed Current Limit FWD 0 – 150% of Full Load Current Limit REV 0 – 150% of Full Load IR Comp/Tach Scaling 0 – 10% IR or 0 – 100% Tach Acceleration/Deceleration 0.1 – 30 Seconds Voltage (Speed) Stability Speed Gain Fine Tune Current Stability FWD Current Gain FWD Fine Tune Current Stability REV Current Gain REV Fine Tune

Efficiency Controller (only) 98%

With Motor (typical) 85%

Approvals & Listings UL and cUL

Page 17: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

258

www.emersonct.com

800-334-3040

Fincor 2200

Circuit Common

+10V Ref-10V Ref

Ext Current Ref Input FWD

Tachometer Fdbk InputRun Enable Input (+24VDC)

+24VDCRun Relay N.O. ContactsRun Relay N.O. Contacts

Controlled Stop Input

Speed Reg Node InputCur. (4 to 20mA) Output Speed

Circuit Common-10 to +10VDC Output Speed

Zero Speed Output

Ext Current Ref Input REV

Speed Ref Input

Direction Output

Circuit Common-10 to +10VDC Output Torque

Circuit Common

Cur. (4 to 20mA) Output Torque

Speed Ref Pot

TorqueRef PotFWD

TorqueRef Pot

REV

K

K

Controlled Stop

TERMINAL DESCRIPTION

Pin# Type Notes

L1 Line Voltage Input 115 or 230VAC J1 Selectable

L2 Line Voltage Input 115 or 230VAC J1 Selectable

F+ Field Voltage Output +100VDC @ 115VAC or +200VDC @230VAC Input

F/2 Field Voltage (Half-Wave) Output

+50VDC @ 115VAC or +100VDC @230VAC Input

F- Field Voltage Output Field Minus Output

A1 Armature Output -90 to +90VDC @ 115VAC or -180 to +180VDC @ 230VAC InputA2 Armature Output

TB1 TB2

TB1

Pin# Type Notes

1 Speed Reference Pot ‘0’ End Speed Pot Common for Uni-Directional Operation

2 Speed Reference Input 200KΩ Input Resistance

3 +10V Reference Output 5ma max

4 -10V Reference Output 5ma max

5 External Current Reference Input FWD

Refer to DIP Switch SW3-2

6 External Current Reference Input REV

Refer to DIP Switch SW3-7

7 Tachometer Input (Speed Feedback)

3-30VDC, 31-175VDC

TB2

TERMINAL DIAGRAM: 2230 MKII

Pin# Type Notes

8 Enable Input (+24VDC) – Run Relay

24VDC @ 6ma Input

9 +24VDC For drive enable use only

10 Run Relay N.O. Contacts Form A Contact Rated 0.5A @ 115VAC or 2A @ 30VDC11 Run Relay N.O. Contacts

12 Controlled Stop Input (+24VDC)

Momentary +24VDC Input to Initiate Controlled (Ramp) to Stop

13 Zero Speed Indication Output Open Collector, Active Low, Rated 24VDC @ 50ma

14 Speed Regulator Node Input Speed Trim or External PID Input (Bypasses Accel/Decel Ramps)

15 Current Loop Output 4 to 20ma – Speed (Arm Volts)

16 Current Loop Output 4 to 20ma – Speed (Arm Volts)

17 Voltage Output -10 to 10VDC – Speed (Arm Volts)

18 Direction Indicator Output Open Collector, Active Low for FWD; Rated 24VDC @ 50ma

19 Current Loop Output 4 to 20ma – Torque (Arm Amps)20 Current Loop

21 Voltage Output -10 to 10VDC – Load (Arm Amps)

22 Voltage Output Common Isolated From Line – Can be connected to Earth

TB2 Continued

Page 18: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

259

www.emersonct.com

800-334-3040

Finc

or 2

200

SPECIFICATIONS: Operating Conditions Horsepower 1/6 thru 3 hp, Clip-out Shunt Wires

Line Voltage 115-230VAC ±10%, Jumper Selectable

Rated Frequency 50/60Hz ±2% Selectable

Enclosure Chassis, NEMA 4/12

Ambient Temperature 0 – 40°C (32°F - 104°F) (Enclosed)

0 – 55°C (32°F - 131°F) (Chassis)

Altitude 1000m (3,300 ft)

Relative Humidity 95% Non condensing

Overload Capacity 150% for 1 minute

Standard Features Regulator Function Speed or Torque selectable

Power Conversion 8 SCR Full Wave - Four Quadrant

Field Supply Full Wave

Protection MOV Voltage Transient Suppression High Interrupting Capacity Line Fuse

Speed Regulation Armature or DC Tach Feedback

Line Start Selectable for Auto-Restart

Zero Speed Deadband Selectable 2% or Off

Option Connector Connects Additional Option Boards

Control Control Logic Power 24VDC for Maintained Switch or Pushbutton Operation

Speed Potentiometer 5K Ohms, ½ Watt

Input Reference 0 – 10Vdc or -10 – +10Vdc

Speed Regulation 2% with Armature Feedback

(95% Load Change) 0.5% with Tachometer Feedback

Adjustments Maximum Speed 50% – 100% of Motor Base Speed

Current Limit FWD 0 – 150% of Full Load

Current Limit REV 0 – 150% of Full Load

IR Comp/Tach Scaling 0 – 10% IR or 0 – 100% Tach

Acceleration/Deceleration 0.2 – 30 Seconds

Efficiency Controller (only) 98%

With Motor (typical) 85%

Approvals & Listings UL and cUL

Fincor Series 2240 DIMENSIONS

2240 Chassis

9”(228 mm)

12.1”(307 mm)

8.6”(218 mm)

Weight (Enclosed)13.2 lbs. 5.99 kg

RUN

JOGSTOP

Adjustable

AdjustableSpeedSpeedDrivesDrives

AdjustableSpeedDrives

MOTOR SPEED (%)

9”(228 mm)

12.1”(307 mm)

8.6”(218 mm)

Weight (Enclosed)13.2 lbs. 5.99 kg

2240 Enclosure

Page 19: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

260

www.emersonct.com

800-334-3040

Fincor 2200

Circuit Common

+10V Ref-10V Ref

Ext Current Ref Input FWD

Tachometer Fdbk InputRun Enable Input (+24VDC)

+24VDCRun Relay N.O. ContactsRun Relay N.O. Contacts

Ext Current Ref Input REV

Speed Ref Input

Speed Ref Pot

TorqueRef PotFWD

TorqueRef Pot

REV

Motor Armature

TB

TB

TB

TB

TERMINAL DIAGRAM: 2240

TERMINAL DESCRIPTION

Pin# Type Notes

L1 Line Voltage Input 115 or 230VAC J1 Selectable

L2 Line Voltage Input 115 or 230VAC J1 Selectable

F+ Field Voltage Output +100VDC @ 115VAC or +200VDC @230VAC Input

F/2 Field Voltage (Half-Wave) Output

+50VDC @ 115VAC or +100VDC @230VAC Input

F- Field Voltage Output Field Minus Output

A1 Armature Output -90 to +90VDC @ 115VAC or -180 to +180VDC @ 230VAC InputA2 Armature Output

TB1Pin# Type Notes

1 Speed Reference Pot ‘0’ End Speed Pot Common for Uni-Directional Operation

2 Speed Reference Input 200KΩ Input Resistance

3 +10V Reference Output 5ma max

4 -10V Reference Output 5ma max

5 External Current Reference Input FWD

Refer to DIP Switch SW3-2

6 External Current Reference Input REV

Refer to DIP Switch SW3-7

7 Tachometer Input (Speed Feedback)

3-30VDC, 31-175VDC

8 Enable Input (+24VDC) – Run Relay

24VDC @ 12ma Input

9 +24VDC For drive enable use only

10 Run Relay N.O. Contacts Form A Contact Rated 0.5A @ 115VAC or 2A @ 30VDC11 Run Relay N.O. Contacts

TB2

TB1

Page 20: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

261

www.emersonct.com

800-334-3040

Finc

or 2

200

Series 2230 MKII Options with Allowable Combinations

Option Groups Use with Model

Order Code Option Code

Option description

Fact. Install Fld. Install

B) Options Used To Convert Open Chassis Units into Enclosed Package Controllers — Choice of one within this group.

2231 - 2236 1639 106353803 XK Cover Assembly, Blank Type “P0”

2231 - 2236 1639C 106353801 XK Cover Assembly, Type “P1”

C) Power Options 2231 - 2236 1001(2 hp) 106242801 XK Armature Contactor With Dynamic Braking (2 hp)

2231 - 2236 1001(3 hp) 106242802 XK Armature Contactor With Dynamic Braking (3 hp)

D) Input Signal Options 2231 - 2236 1048 106334702 XK Limit Switch Reversing

E) Feedback Options — Choice of one within this group.

2231 - 2236 1190 106342803 XK Torque Taper

2231 - 2236 1670 106345202 XK Pulse Tachometer Feedback/Follower

G) External Options — Choice of any or all within this group.

2231 - 2236 1120 104259401 K Operator Control Station — Remote

2231 - 2236 1120A 2660168 K Motor Speed Potentiometer, Ten-Turn With Analog Dial

2231 - 2236 1120B 104192505 K Motor Speed Potentiometer, One-Turn

2231 - 2236 1120C 104319401 K Motor Speed Potentiometer, Ten-Turn With Digital Dial

2231 - 2236 1166 BOOK 0873 K Extra Equipment Manuals

2231 - 2236 1614 106349301 XK Option/Contactor Mounting Kit for 2235 or 2236

Notes: XK–Factory or Field Kit, K–Field Kit, P–Plug-In Option

Series 2240 Options with Allowable Combinations

Option Groups Use with Model

Order Code Option Code

Option description

Fact. Install Fld. Install

A) Enclosure Options — Choice of any or all within this group.

2242 1170A 106151401 XK Fan Assembly (5 hp Units Only) (Required When En-closed Model 2242 is Operated at 5 hp Rating)

2242 1638 105567001 XK Hinge kit to allow the cover to swing open

B) Options Used To Convert Open Chassis Units into Enclosed Package Controllers — Choice of one within this group.

2242 1639 106356403 XK Cover Assembly, Blank Type P0

2242 1639C 106356401 XK Cover Assembly, Type P1

2242 1001(3 hp) 10624802 XK Armature Contactor With Dynamic Braking (3 hp)

2242 1001(5 hp) 10624803 XK Armature Contactor With Dynamic Braking (5 hp)

2242 1010(3 hp) 105535403 XK Circuit Breaker — Two Pole (3 hp)

2242 1010(5 hp) 105535404 XK Circuit Breaker — Two Pole (5 hp)

D) Input Signal Options — Choice of one within this group.

2242 1036 106318202 XK Four-Quadrant Acceleration/Deceleration

2242 1048 106334702 XK Limit Switch Reversing

2242 1052 106330702 XK Isolated Input

E) Feedback Options — Choice of one within this group.

2242 1190 106342803 XK Torque Taper

2242 1670 106345202 XK Pulse Tachometer Feedback/Follower

G) External Options — Choice of any or all within this group.

2242 1120 104259401 K Operator Control Station — Remote (SCS171)

2242 1120A 2660168 K Motor Speed Potentiometer, Ten-Turn With Analog Dial

2242 1120B 104192505 K Motor Speed Potentiometer, One-Turn

2242 1120C 104319401 K Motor Speed Potentiometer, Ten-Turn With Digital Dial

2242 1166 BOOK 0873-B K Extra Equipment Manuals

2242 1611 106360301 XK Option Guide Card Kit

Notes: XK–Factory or Field Kit, K–Field Kit, P–Plug-In Option

Page 21: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

262

www.emersonct.com

800-334-3040

Fincor

Fincor Series 2330, 2230, 2240, 2600, 2610 Detailed Option DescriptionsOption Controller Description

1001 2230, 2240

Motor Contactor with Dynamic Braking — The basic series 2230 and 2240 controllers are designed for bidirectional operation without an armature contactor. This option provides a two pole armature contactor which is necessary whenever the application requires a positive discon-nection of the rectifi ed armature source from the motor on a stop command. This option also includes a dynamic braking resistor which provides exponential rate braking of the DC motor armature and an anti-plug circuit to prevent restarting the controller until the braking cycle is complete. The dynamic braking resistor is rated for stopping a typical load, when the external machine inertia does not exceed that of the motor armature.

1004 2600, 2610

Armature Contactor Kit - Reverse Run and Dynamic Braking. This option is included with reversing and DB confi gurations.

1010 2240, 2600

AC Line Circuit Breaker, Two Pole — Provides a two-pole, magnetic only, fast trip circuit breaker as a means of manually disconnecting the Model 2242 controller from the AC line. The high interrupting capacity fuse in the basic unit is retained as primary short circuit protection.

1015 2600 Magnetic Control Interface for 115VAC control. 1022 2610 Jog, Toggle Switch Selection Option includes a RUN-JOG selector switch and a JOG SPEED potentiometer for installation in the operator control

panel. The RUN-JOG toggle switch (maintained) contacts in the operator station open the contactor seal-in circuit. Controller then jogs when the RUN pushbutton is pressed and held at the JOG SPEED potentiometer setting. Jog action is momentary, causing motor rotation only when the RUN pushbutton is depressed. This option is also suitable for reversing units where identical forward and reverse jog speeds are acceptable.

1036 2240 Four-Quadrant Acceleration/Deceleration — This option board has four adjustment potentiometers consisting of a forward acceleration potenti-ometer, a forward deceleration potentiometer, a reverse acceleration potentiometer and a reverse deceleration potentiometer. The potentiometers have an adjustment range of .3 to 30 seconds.

1037 2600 Input / Feedback Adapter Interface Board - Brings the internal regulator circuits of the control board to screw terminal connection points. 1037A 2600 Input / Feedback Adapter, 1-Position - Assembly capable of accepting either a standard input option board or a feedback option board. (external) 1037B 2600 Input / Feedback Adapter, 2-Position - Assembly capable of accepting feedback and input boards. (external) 1048 2230,

2240Limit Switch Reversing — This option board allows interfacing the controller with a variety of external devices, such as limit switches, push buttons and potentiometers. There are two speed potentiometers on this board, one for forward speed and one for reverse speed. These internal potentiometers can be switched out if external potentiometers are required. In addition, this board will allow a controlled stop feature with an adjustable speed dropout.

1049 1 2600 External DC Signal Follower Provides necessary impedance matching, isolation, signal conversion and fi ltering as required to adjust the speed of the drive (or drives) from an external DC signal source.

1050 1 2600, 2610

External AC Signal Follower Provides necessary impedance matching, isolation, signal conversion and fi ltering as required to adjust the speed of the drive (or drives) from an external AC signal source.

1050A 1 2600, 2610

AC Current Transducer Follower, Intended for automatic control systems where it is necessary for the drive to follow an AC signal proportional to the load current of an AC constant speed, induction motor. Typical examples are conveying systems where the material feed rate has a direct infl u-ence over the loading of the AC motor, i.e: the carriage or conveyor feeding logs to a saw powered by an AC motor. In order that a proper current transformer may be supplied it is necessary that nameplate data such as horsepower, voltage, load current, etc. be provided from the AC motor.

1052 2240 Isolated Input and Follower — This option board isolates the motor speed potentiometer from the non-isolated controller for operator and equip-ment safety. Also, it will allow the controller to follow a 4-20mA DC current signal and a wide range of DC voltage signals (±.05 to ±500 VDC). This makes the option ideal for following signal transducers, motor shunts, DC tachometer generators and the armature voltage from DC motors.

1055 1 2600, 2610

AC or DC Tachometer Generator Follower, Intended for automatic control systems where it is necessary for the drive to follow the speed of a pre-ceding drive unit or rotating machine coupled to an AC or DC tachometer generator. The tachometer voltage signal provides the speed reference for the “follower” drive. Option 1055 is not recommended for use where multiple drive controllers are required to operate from a common signal source, unless the controllers are isolated.

1057A 1 2600, 2610

Digital Pulse Generator Follower, This option provides signal conditioning and isolation for accepting a signal from a magnetic pulse pick-up mechanically coupled to a preceding drive motor, rotating machinery or various static pulse generators permitting the drive to follow at an adjust-able ratio.

1058A 2610 Manual/Follower Mode Select (Toggle Switch) This option is intended as a companion to Option 1055, Option 1049 and Option 1052. Options 1055, 1049 and 1052 do not include a selector switch and rely upon a zero speed setting of the MOTOR SPEED potentiometer to transfer to full automatic control by the external signal. Option 1058A, when used with these options, allows manual switch selection of either the MOTOR SPEED potentiometer or automatic control by the external signal. Option 1058A includes a switch with a MANUAL/FOLLOWER legend plate for installation in the operator control panel.

1059 1 2600 Precision Reference - Includes a regulated power supply.

1059A 2610 This option provides a ±24/12VDC power supply source to provide power to operate a remote transmitter requiring an external power source. It has a power output capability of 100mA total for all the power outputs inclusively. This option requires external mounting by the customer and requires a .5amp fused 115/230V power source supplied by the customer.

1061C 1 2600 AC or DC Tachometer Feedback

1062A 2600, 2610

Digital Pulse Generator Feedback, Provides signal conditioning and isolation for accepting a signal from a magnetic pulse pick-up mechanically coupled to the drive motor armature. The magnetic pulse pick-up must provide a minimum of 450 pulses per second at motor speed (60 tooth gear on a 1750 RPM motor). The pulse pick-up signal defeats the IR compensation circuitry in the drive controller, making the unit directly sensi-tive to motor speed. Speed range is limited to 35:1. The option results in improved speed regulation with load changes (equal to DC tachometer feedback) and reduced sensitivity to operating conditions such as line voltage variations, ambient temperature changes, motor fi eld heating and other variables.

Page 22: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

263

www.emersonct.com

800-334-3040

Finc

or

Fincor Series 2330, 2230, 2240, 2600, 2610 Detailed Option DescriptionsOption Controller Description

1064A 2610 Current Regulator Follower, Provides a means of controlling motor armature current and torque by a manually adjusted potentiometer or an external DC voltage reference signal. The circuit includes internal isolation permitting direct connection to a grounded signal source or the arma-ture circuit shunt of another DC drive controller. Since torque is directly controlled independent of motor speed, provision is included for limiting maximum motor speed.

1072 2600A Auxiliary Contacts - This option can only be used with the 2601A and 2602A if it is to be mounted in the controller enclosure.

1081B 2 2600, 2610

Torque (Current) Monitor Provides an adjustable, static circuit that monitors motor armature current and provides a programmed shutdown of the drive under sustained overload conditions to prevent motor damage. The circuit provides greater versatility than the standard, nonadjustable overload circuit calibrated to trip whenever armature current exceeds 120% for 80 seconds.

1120A 2330, 2240, 2600, 2610

Potentiometer, Ten-Turn Motor Speed (Analog Dial) — Provides a ten-turn, 2W potentiometer, knob and analog counting dial for separate mount-ing by user.

1120B 2330, 2240, 2600, 2610

Potentiometer, Single-Turn Motor Speed Assembly — Provides a single-turn, 2W potentiometer, knob and dial wired to a terminal board for separate mounting by user.

1120C 2330, 2240, 2600, 2610

Potentiometer, Ten-Turn Motor Speed (Digital Dial) — Provides a ten-turn, 2W potentiometer, with digital counting indicator dial assembly for separate mounting by user.

1170A 2240, 2600

Fan Assembly — All 2242 enclosed models (used for 5 hp) require this fan assembly when operated at the fi ve horsepower rating in a 40°C en-vironment. Option includes a special base assembly/air baffl e with a 24 VDC fan powered by a power supply within the Model 2242. This option may also be used for ratings less than fi ve horsepower when open chassis models must operate in environments greater than 55°C, and enclosed models above 40°C.

1072 2600A Auxiliary Contacts - This option can only be used with the 2601A and 2602A if it is to be mounted in the controller enclosure.

1081B 2 2600, 2610

Torque (Current) Monitor Provides an adjustable, static circuit that monitors motor armature current and provides a programmed shutdown of the drive under sustained overload conditions to prevent motor damage. The circuit provides greater versatility than the standard, nonadjustable overload circuit calibrated to trip whenever armature current exceeds 120% for 80 seconds.

1190 1 2230, 2240, 2600, 2610

Torque Taper— This option consists of a plug-in circuit board. This board provides an inverse-linear speed-torque relationship when operating in the braking (regenerative) mode, and provides constant torque in the motoring mode of operation. Motoring torque and braking torque are indi-vidually adjustable as well as forward and reverse torque taper. Applications include the following: 1. Winders where the material being wound travels at a constant speed during winder roll buildup. 2. Unwinders, since this option provides relatively constant holdback tension (±20%) from full roll to empty roll.

1220 1 2600, 2610

Constant Velocity Winder This option provides an economical but accurate method of automatically controlling the tension of process material in strip, web, wire or cable form as wound by a center driven winder.

1611 2240 Option Card Guide Kit — This option is required when mounting the option cards in the 2242 enclosure or if the option cards are mounted external.

1614 2230 Option Mounting Kit — This kit contains standoffs for mounting an optional contactor or option board onto a Series 2235 or 2236 “Bookcase” chassis.

1638 2240, 2600

Hinge Kit, Enclosure Cover — Model 2242 enclosed controllers include a screw fi xed, gasket cover which is removable for increased accessibility during installation, troubleshooting or repair. When desired the cover may also be provided with optional hinges making servicing more conve-nient. This option may be provided factory installed or a kit is offered for simple fi eld installation.

1639 2230, 2240

Cover Kit, Blank Type “P0” — Provides an enclosed blank (no operator devices) cover for fi eld conversion of open chassis models (except 2235, 2235B, 2236 and 2236B models) into an enclosed unit for remote control.

1639C 2230, 2240

Cover Kit, Type “P1” (Run-Stop-Jog) — Provides an enclosed (run-stop-jog switch with motor speed potentiometer) cover for fi eld conversion of open chassis models (except 2235, 2235B, 2236 and 2236B models) into an enclosed unit for local control.

1670 2230, 2240

Pulse Tachometer Feedback/Follower — This option interfaces the controller to a pulse train for speed reference or as a feedback signal. It allows the use of a 60 tooth gear for either speed reference or feedback. It is capable of providing digital pulse tach reference and/or feedback functions. The sensor can be a magnetic pickup (2 wire), proximity sensor (3 wire), AC tachometer generator (18 cycles/revolution), two-phase AC tachometer generator, or digital tachometer generator or encoder (240 pulses/revolution). Note: two phase AC tachometer generator can be used for follower or feedback applications, but not both.

1775 2600, 2610

Signal Options Interface. Required to enable the use of all options marked with Note (1). Option 1775 mounts within the chassis of Models 2601 or 2602 and externally when used with Models 2611 and 2612.

Notes: 1 Requires Option 1775 Signal Options Interface.2 Not compatible with tachometer feedback.

Page 23: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

264

www.emersonct.com

800-334-3040

Fincor DC M

otors

Fincor DC MotorsPermanent Magnet DC Motors Series 9300Fincor Series 9300 permanent magnet motors are industrial rated general purpose DC motors designed for use with single-phase DC drives. They provide constant-torque adjustable-speed operation by armature voltage control to base speed. The motors are suitable for a wide range of applications including full power start-stop conditions, continuous high speed operation, precision speed regulation, regenerative braking and reversing, low speed contactor reversing, power off dynamic braking, and crawling duty.

Series 9300 motors feature a permanent magnet field with a conventional wound armature and feature excellent starting torque, speed regulation, dynamic response, and heat dissipation. Series 9300 motors should only be plug reversed when reversing currents are limited to less than locked rotor current.

HPBase

SpeedArmVolts

ArmAmps

Enclosure FrameStock

Number Order Code

Weight(lbs)

1/6 1725 90 2.2 TENV 56C 5009322 9301609TNL 151/4 1725 90 2.5 TENV 56C 5009323 9302509TNL 171/3 1725 90 3.5 TENV 56C 5009324 9303309TNL 21

1/2 172590 5 TEFC 56C 5009325 9305009TFL 25180 2.5 TEFC 56C 5009326 9305018TFL 25

3/4 172590 7.3 TEFC 56C 5009327 9307509TFL 32180 3.8 TEFC 56C 5009328 9307518TFL 32

1 172590 10.6 TEFC 56C 5009329 9310009TFL 39180 5 TEFC 56C 5009330 9310018TFL 39

1.5 1750 180 7.5 TEFC 145TC 5009331 9315018TFL 682 1750 180 9.5 TEFC 145TC 5009332 9320018TFL 733 1750 180 12.9 TEFC 182/45TC 5009333 9330018TFL 935 1750 180 19.6 TEFC 1810ATC 5008070 9350018TFB 157

Removable Mounting Feet are IncludedAll items normally stocked

Permanent Magnet DC Motors - Series 9300

% RATED TORQUE (TYPICAL)

0

40

100%

RA

TE

D S

PE

ED

120

60

80

20

D-CSupply

A

100 500400300200

N S

SPEED TORQUE CURVE

Page 24: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

265

www.emersonct.com

800-334-3040

Finc

or D

C M

otor

s

Description Factory Installed 2

Order CodeField InstalledOrder Code

AC Tachometer Generator, 50 VAC/1000 RPM, Double C-Face Mounted, with load shaft

56C motor frame -5055A (56) 3120036

145 to 184TC motor frames -5055A (184) 3120037

Digital Pulse Generator - C-Face mounted adapter ring with magnetic pickup and motor shaft

56C motor frame -5055B (56) 3110012

145 to 184TC motor frames -5055B (184) 3110011

DC Tachometer Generator Type XPY, 50V/1000 RPM with mounting hardware

1/6 to 3/4 hp -5056 (56-3/4) 106890101

1 hp -5056 (56-1) 106890102

182/145TC motor frames -5056 (145) 106890103

DC Tachometer Generator 50V/1000 RPM, with mounting hardware 1

1/6 to 3/4 hp -5056F (56-3/4) 106890201

1 hp motor -5056F (56-1) 106890202

182/145TC motor frames -5056F (145) 106890203

Mounting Hardware Only for XPY or Fincor DC Tachometer Generator

1/6 to 3/4 hp -5063A (56-3/4) 106890301

1 hp -5063A (56-1) 106890302

182/145TC motor frames -5063A (145) 106890303

Thermostat -5064A

Options for Model TNL, TFL Series 9300 DC Motors

(1) Not suggested for use with regenerative drives.(2) Factory Installed Options Not Returnable

All motors are designed to comply with standard NEMA mounting dimensions, and manufactured to meet or exceed NEMA electrical and mechanical specifi cations and test procedures.

TNL & TFL Models TFL ModelsHP

Model Number

AG Maximum 1 Wt. (Lbs.) 2 Enclosure

ªAº ªBº

1/6 9301609TNL 7.13 – 15TENV1/4 9302509TNL 7.66 – 17

1/3 9303309TNL 8.16 – 21

1/29305009TFL – 9.875

25

TEFC

9305018TFL – 9.875

3/49307509TFL – 12.375

329307518TFL – 12.375

19310009TFL – 14.375

399310018TFL – 14.375

AG MAX.TEFC

AG MAX.TENV4.483.60.88 DIA.1.80

2.68.61

4.56

3.47

5.13NOM.

.36

.34 3.03*2.97

4.00 MAX.2.56

NOM.

2.0852.035

.6248

.6245

.16 MAX.

1.41 MIN.

KEYWAY

* MOUNTING FEET ARE OPTIONAL.

SEE SHAFTDETAIL

6.5NOM.

3/8-16 UNC-2B HOLE–

4 EQUALLY SPACED

ON A5.875 D.B.C. 3.12

1.56

8.06NOM.

45°3.503.47

2.4552.425 4.91

4.85

4.5004.497

1.41 MIN.

6.50

D3.50/3.47E

A7.0 MAX.

E.2765/2.735

U.8750/.8745 DIA.

FULL KEYWAY

ES1.41 MIN.

V2.0 MIN.

AH2.145/2.095

AK4.500/4.497 DIA.

.56 DEEPEQUALLY SPACED

BF3/8-16 UNC-2B (4)

BD6.5 O.D.

S.190/.188

AJ5.875 D.B.C.

*The optional mounting feet have six mounting holes for mounting either the 143TC or 145TC Frame. 2F: 143TC Frame 4.030/3.970 2F: 145TC Frame 5.030/4.970

AG MAX.BAA

3/4-14 NPT BB.160 MAX.

N-W2.13

BC.12

BA2.75

*2F*2F

B6.0 MAX.

H.390/.340

DIA.

Notes: 1 To convert dimension fi gures shown to metric equivalents (mm) multiply by 25.4.2 To convert weights shown to metric equivalents (kgs) multiply by 0.45.

HPModel

NumberAG Maximum 1 Wt.

(Lbs.) 2 EnclosureªBº

1 1/2 9315018TFL 16.35 68TEFC2 9320018TFL 17.35 73

3 9330018TFL 19.75 93

Page 25: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

266

www.emersonct.com

800-334-3040

Fincor DC M

otors

Fincor DC MotorsShunt Wound DC Motors - Series 9200Fincor Series 9200 motors are industrial rated general purpose DC motors designed for use with single-phase DC drives. Series 9200 motors are shunt-wound, or stabilized shunt-wound and are suitable for constant torque-adjustable speed operation by armature voltage control to base speed. The field winding is typically excited by a separate power supply. With constant armature voltage and field excitation, a shunt-wound motor offers relatively flat speed-torque characteristics.

Options for Model TFB & DPB Series 9200 DC Motors

Shunt Wound DC Motors - Series 9200

DescriptionFactory Installed 2

Order Suffi xField InstalledOrder Code

AC Tachometer Generator, 50 VAC/1000 RPM, Double C-Face Mounted, with load shaft

56C motor frame -5055A (56) 3120036145 to 184TC motor frames -5055A (184) 3120037

Digital Pulse Generator - C-Face mounted adapter ring with magnetic pickup and motor shaft

56C motor frame -5055B (56) 3110012145 to 184TC motor frames -5055B (184) 3110011215C motor frames -5055B (215) 3110014256UC motor frames -5055B (256) 3110013

DC Tachometer Generator Type XPY, 50V/1000 RPM with mounting hardware

1/6 to 3/4 hp -B5056 (-3/4) 1063432221 hp -B5056 (1) 1063432231.5 to 2 hp -B5056 (1.5-2) 1063432243 hp DPG -B5056 (3DP) 1063432253 hp TEFC -B5056 (3FC) 1063432265 hp DPG -B5056 (5DP) 1063432275 hp TEFC -B5056 (5FC) 106343228

DC Tachometer Generator 50V/1000 RPM, with mounting hardware 1

1/6 to 3/4 hp -B5056F (-3/4) 1063432291 hp -B5056F (1) 1063432301.5 to 2 hp -B5056F (1.5-2) 1063432313 hp DPG -B5056F (3DPG) 1063432323 hp TEFC -B5056F (3FC) 1063432335 hp DPG -B5056F (5DPG) 1063432345 hp TEFC -B5056F (5FC) 106343235

Mounting Hardware Only for XPY or Fincor DC Tachometer Generator for

1/6 to 3/4 hp -B5063A (-3/4) 1043558011 hp -B5063A (1) 1043558091.5 to 2 hp -B5063A (1.5-2) 1043558083 hp DPG -B5063A (3DPG) 1043558043 hp TEFC -B5063A (3FC) 1043558055 hp DPG -B5063A (5DPG) 104355806 5 hp TEFC -B5063A (5FC) 104355807

Thermostats -B5064A

(1) Not suggested for use with regenerative drives.(2) Factory Installed Options Not Returnable

Field Installed items are shipped “loose” for customer mounting Consult Factory for Availability

HPBase

SpeedArmVolts

ArmAmps

FieldVolts

Enc FrameStock

Number Order Code

Weight(lbs)

1/6 1750 90 2 50/100 TEFC 56C 5002698 9201609TFB 231/4 1750 90 2.8 50/100 TEFC 56C 5002319 9202509TFB 241/3 1750 90 3.5 50/100 TEFC 56C 5002396 9203309TFB 24

1/2 1750 90 5.4 50/100 TEFC 56C 5002291 9205009TFB 29180 2.6 100/200 TEFC 56C 5002454 9205018TFB 29

3/4 1750 90 8.1 50/100 TEFC 56C 5002320 9207509TFB 34180 3.8 100/200 TEFC 56C 5002292 9207518TFB 34

1 1750 90 10.5 50/100 TEFC 56C 5002401 9210009TFB 52180 5.5 100/200 TEFC 56C 5002649 9210018TFB 53

1.5 1750 180 8.2 100/200 DPG 184C 5002378 9215018DPB 84TEFC 184C 5002648 9215018TFB 84

2 1750 180 11.6 100/200 DPG 184C 5002631 9220018DPB 98TEFC 184C 5002632 9220018TFB 98

3 1750 180 15.1 100/200 DPG 215C 5002248 9230018DPB 137TEFC 215C 5002284 9230018TFB 137

5 1750 180 24 100/200 DPG 256UC 5002297 9250018DPB 304TEFC 256UC 5002296 9250018TFB 304

All items normally stocked

Page 26: 800-334-3040 Fincor DC Drives - SIECA - Servicios de … · 2008-02-07 · 242 800-334-3040 Fincor Fincor DC Drives Flexible & Powerful Fincor single-phase DC drives provide a complete

267

www.emersonct.com

800-334-3040

Finc

or D

C M

otor

s

% RATED TORQUE (TYPICAL)

0

40

100

% R

AT

ED

SP

EE

D

120

60

80

20

SH

UN

T F

IEL

D

D-CSupply A

100 500400300200

TBF & DPB Models

BF

AJ

EE

D

O

P

45°

OPEN MOTOR ONLY

UAK

KEYC (TEFC)

C (OPEN)

FPDIA.

VENTS-OPENMOTOR ONLY

H = HOLE

F BA

AH

45°

HPFrame Size 1

Model Number

Dimensions, Inches 2

C D E F H Key O P U AH AJ AK BA BF(tap) FP

1-1/2184C

9215018DPB 15.438 4.5 3.75 5.5 0.406 0.188 8.375 7.75 0.875 2.125 5.875 4.5 2.75 3/8-16 –9215018TFB 17.375 4.5 3.75 5.5 0.406 0.188 8.375 7.75 0.875 2.125 5.875 4.5 2.75 3/8-16 8.5

29220018DPB 18.625 4.5 3.75 5.5 0.406 0.188 8.375 7.875 0.875 2.125 5.875 4.5 2.75 3/8-16 8.59220018TFB 18.625 4.5 3.75 5.5 0.406 0.188 8.375 7.75 0.875 2.125 5.875 4.5 2.75 3/8-16 8.5

3 215C9230018DPB 20.938 5.25 4.25 7.0 0.406 0.25 9.938 9.375 1.125 2.75 7.25 8.5 3.5 1/2-13 –9230018TFB 21.188 5.25 4.25 7.0 0.406 0.25 9.938 9.375 1.125 2.75 7.25 8.5 3.5 1/2-13 10.188

5 256UC9250018DPB 24.75 6.25 5.0 10.0 0.531 0.313 11.938 11.375 1.375 3.50 7.25 8.5 4.25 1/2-13 –9250018TFB 25.875 6.25 5.0 10.0 0.531 0.313 11.938 11.375 1.375 3.50 7.25 8.5 4.25 1/2-13 12.375

F BA

U

AK

KEY

AH (215C, 256 UC)AH (184C)

C

FPDIA.

11/16(REF.)

O

D

E E

H = HOLE

AJ

BF45°

LEAD HOLE7/8 DIA.

45°

TBF Models

HPFrame Size 1

Model Number

Dimensions, Inches 2

C D E F H Key O P U AH AJ AK BA BF(tap) FP1/6

56C

9201609TFB 13.25 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.1251/4 9202509TFB 13.25 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.1251/3 9203309TFB 13.25 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.125

1/29205009TFB 14.25 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.1259205018TFB 14.25 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.125

3/49207509TFB 14.75 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.1259207518TFB 14.75 3.5 2.438 3.0 or 4.0 0.344 slot 0.188 7.25 5.688 0.625 2.06 5.875 4.5 2.75 3/8-16 6.125

19210009TFB 16.125 3.5 2.438 3.0 0.406 slot 0.188 7.75 6.625 0.625 2.06 5.875 4.5 2.75 3/8-16 7.1889210018TFB 16.125 3.5 2.438 3.0 0.406 slot 0.188 7.75 6.625 0.625 2.06 5.875 4.5 2.75 3/8-16 7.188

Notes: 1 1750 RPM Base Speed only.2 Dimensions for estimating only.

SPEED TORQUE CURVE