Energy Performance Certificate Page 1 of 4 East Castle, Tiers Cross, HAVERFORDWEST, SA62 3EG Dwelling type: Detached house Reference number: 0469-3842-6071-9906-5285 Date of assessment: 02 March 2016 Type of assessment: SAP, new dwelling Date of certificate: 02 March 2016 Total floor area: 301 m² Use this document to: Compare current ratings of properties to see which properties are more energy efficient Find out how you can save energy and money by installing improvement measures Estimated energy costs of dwelling for 3 years: £ 2,832 Estimated energy costs of this home Current costs Potential costs Potential future savings Lighting £ 411 over 3 years £ 411 over 3 years Heating £ 2,172 over 3 years £ 2,172 over 3 years Hot Water £ 249 over 3 years £ 249 over 3 years Totals £ 2,832 £ 2,832 Not applicable These figures show how much the average household would spend in this property for heating, lighting and hot water. This excludes energy use for running appliances like TVs, computers and cookers, and any electricity generated by microgeneration. Energy Efficiency Rating The graph shows the current energy efficiency of your home. The higher the rating the lower your fuel bills are likely to be. The potential rating shows the effect of undertaking the recommendations on page 3. The average energy efficiency rating for a dwelling in England and Wales is band D (rating 60). Actions you can take to save money and make your home more efficient Recommended measures Indicative cost Typical savings over 3 years 1 Solar photovoltaic panels, 2.5 kWp £5,000 - £8,000 £ 879

Transcript of pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area...

Page 1: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Energy Performance Certificate

Page 1 of 4

East Castle, Tiers Cross, HAVERFORDWEST, SA62 3EGDwelling type: Detached house Reference number: 0469-3842-6071-9906-5285Date of assessment: 02 March 2016 Type of assessment: SAP, new dwellingDate of certificate: 02 March 2016 Total floor area: 301 m²

Use this document to:• Compare current ratings of properties to see which properties are more energy efficient• Find out how you can save energy and money by installing improvement measures

Estimated energy costs of dwelling for 3 years: £ 2,832

Estimated energy costs of this home Current costs Potential costs Potential future savings

Lighting £ 411 over 3 years £ 411 over 3 years

Heating £ 2,172 over 3 years £ 2,172 over 3 years

Hot Water £ 249 over 3 years £ 249 over 3 years

Totals £ 2,832 £ 2,832

Not applicable

These figures show how much the average household would spend in this property for heating, lighting and hotwater. This excludes energy use for running appliances like TVs, computers and cookers, and any electricitygenerated by microgeneration.

Energy Efficiency Rating

The graph shows the current energy efficiency of yourhome.

The higher the rating the lower your fuel bills are likelyto be.

The potential rating shows the effect of undertakingthe recommendations on page 3.

The average energy efficiency rating for a dwelling inEngland and Wales is band D (rating 60).

Actions you can take to save money and make your home more efficient

Recommended measures Indicative cost Typical savingsover 3 years

1 Solar photovoltaic panels, 2.5 kWp £5,000 - £8,000 £ 879

Page 2: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Energy Performance CertificateEast Castle, Tiers Cross, , HAVERFORDWEST, SA62 3EG02 March 2016 RRN: 0469-3842-6071-9906-5285

Elmhurst Sap 2012 Desktop 1.16r09 (SAP9.92)

Page 2 of 4

Summary of this home's energy performance related featuresElement Description Energy Efficiency

Walls Average thermal transmittance 0.25 W/m²K

Roof Average thermal transmittance 0.17 W/m²K

Floor Average thermal transmittance 0.12 W/m²K

Windows Fully double glazed

Main heating Boiler and radiators, oil

Main heating controls Time and temperature zone control

Secondary heating Room heaters, wood logs —

Hot water From main system, plus solar

Lighting Low energy lighting in 83% of fixed outlets

Air tightness Air permeability 8.0 m³/h.m² (as tested)

Thermal transmittance is a measure of the rate of heat loss through a building element; the lower the value the betterthe energy performance.Air permeability is a measure of the air tightness of a building; the lower the value the better the air tightness.

Current primary energy use per square metre of floor area: 67 kWh/m² per year

Low and zero carbon energy sourcesLow and zero carbon energy sources are sources of energy that release either very little or no carbon dioxideinto the atmosphere when they are used. Installing these sources may help reduce energy bills as well as cuttingcarbon. The following low or zero carbon energy sources are provided for this home:• Biofuel secondary heating• Solar water heating

Page 3: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Energy Performance CertificateEast Castle, Tiers Cross, , HAVERFORDWEST, SA62 3EG02 March 2016 RRN: 0469-3842-6071-9906-5285

Page 3 of 4

RecommendationsThe measures below will improve the energy performance of your dwelling. The performance ratings afterimprovements listed below are cumulative; that is, they assume the improvements have been installed in the orderthat they appear in the table. Further information about the recommended measures and other simple actions youcould take today to save money is available at www.direct.gov.uk/savingenergy. Before installing measures,you should make sure you have secured the appropriate permissions, where necessary. Such permissions mightinclude permission from your landlord (if you are a tenant) or approval under Building Regulations for certain typesof work.

Recommended measures Indicative cost Typical savingsper year

Rating afterimprovement

Solar photovoltaic panels, 2.5 kWp £5,000 - £8,000 £ 293

Page 4: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Building Regulation Compliance Page 1 of 3

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

CHECKLIST FOR DWELLING AS BUILT

Site reference

Builder

Builder Control body

SAP assessment by

Plot reference

Contact

Contact

Contact

Evidence of competency:

Tel:

Tel:

Tel:

Elmhurst Energy Systems Accredited Assessor. ID I000-0008

Ian Macrae

No. Check Evidence Produced by Design OK

1 Criterion 1: Predicted carbon dioxide emission from proposed dwelling does not exceed the target.

(kg CO2/m )1.1 N/AAuthorised SAP AssessorTER Main fuel - OilFuel factor = 1.17TER = 19.15

2

DER for(kg CO2/m )

1.2 N/AAuthorised SAP AssessorDER = 16.682

dwelling as built

1.3 Authorised SAP AssessorDER 16.68 < TER 19.15 OKAre emissions from dwelling as built less than or equal to the target?Criterion 2: The performance of the building fabric and the heating, hot water and fixed lighting systems should be no worse than the design limits.

2

OK0.28 (0.70)0.18 (0.35)0.12 (0.70)2.50 (3.30)

0.25 (0.35)0.17 (0.25)0.12 (0.25)1.96 (2.20)

Highest Average ElementWallRoofFloorOpenings

Authorised SAP AssessorAre all U-values better than the design limits in Table 2?

Fabric U-values2.1OKOKOKOK

Common areas in buildings with multiple dwellings (where relevant)

If the common areas are un-heated, are all U-values better than the limits in Table 2?(If heated, use L-2A)

2.2 Builder’s submission N/ASchedule of U-values

Heating and hot water systems

2.3 Does the efficiency of the heating systems meet the minimum value set out in the Domestic Heating Compliance Guide?

OKAuthorised SAP AssessorOil condensing, Pumped: pump in heated spaceEfficiency - Database: 95.0%Minimum permitted: 85.0% - OKSecondary heating: Manufacturer's data: Vision 500, Tested to BS EN 13229, HETAS approved Manufacturer: clearview Stoves, Efficiency: 65.2%Minimum permitted: 65.0% - OK

Main heating system :

2.4 Does the insulation of the hot water cylinder meet the standards set out in the Domestic Heating Compliance Guide?

Authorised SAP Assessor Cylinder :Volume = 300 litresNominal cylinder loss: 3.36 kWh/dayPermitted by DHCG: 3.98 kWh/day - OKPrimary pipework insulated: Yes - OK

OK

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 5: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Building Regulation Compliance Page 2 of 3

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

CHECKLIST FOR DWELLING AS BUILT

No. Check Evidence Produced by Design OK

Dedicated solar store volume: 150 litres (separate store) (required: 70 l) - OK

Solar Cylinder :

Space heating control :2.5 Do controls meet the minimum controls provision set out in the Domestic Heating Compliance Guide?

Authorised SAP AssessorTime and temperature zone control - OK

OK

Hot water control :Cylinder thermostat - OKSeparate water control - OK

2.6 Does the heating and hot water system meet the other minimum provisions in the Domestic Heating Compliance Guide?

Schedule of compliance provisions Builder’s submission

Fixed internal and external lighting

2.7 Does fixed internal lighting comply with paragraphs 42 and 44?

Schedule of installed fixed internal lighting

Builder’s submission(see schedule below)

OKLight fittings: 48, L.E.L. fittings: 40 = 83.00% > 25% - OKL.E.L. fittings required per 25m2 or part of TFA: 13 < 40 - OK

2.8 Does the external lighting comply with paragraph 45?

Schedule of installed external lighting Builder’s submission(see schedule below) OKExternal lights: Yes, controlled: Yes

Criterion 3: The dwelling has appropriate passive control measures to limit solar gains.3

Does the dwelling have a strong tendency to high summertime temperatures?

3.1 OKRegion: Wales (14)Thermal mass parameter = 19.0Ventilation rate in hot weather = 8.0Overheating risk (Orientation 'S') = Not significant - OK

Authorised SAP Assessor

4 Criterion 4: The performance of the dwelling, as built, is consistent with the DER.

4.1 Have the key features of the design been included (or bettered) in practice?

N/AWall U-value 0.25 < 0.28Floor U-value 0.12 < 0.20Wall U-value 0.21 < 0.28Roof U-value 0.14 < 0.15Boiler efficiency 95.0% (> 89.0%)Openings U-value 1.30 < 1.80Solar panel

Authorised SAP Assessor

Fabric construction

Builder’s submissionSchedule of details used and their reference codes.

Have accredited details been adopted?

4.2

Builder’s submissionEvidence that details conform to standards set out in IP/06.

Have non-accredited details been used?

4.3

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 6: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Building Regulation Compliance Page 3 of 3

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

CHECKLIST FOR DWELLING AS BUILT

No. Check Evidence Produced by Design OK4.4 Builder’s submissionCompleted pro-formas showing

checklists have been completed.Has satisfactory documentary evidence of site inspection checks been produced?

N/A

4.5(m /(h.m ) at 50Pa)

Actual air permeability = 8.0 OK23

Authorised SAP AssessorActual air permeability

N/ASample pressure test results in comparison to design value.

Has evidence been provided that demonstrates that the Actual air permeability has been achieved satisfactorily (see paragraph 56)

4.6 Builder’s submission(see schedule below)

Commissioning heating and hot water systems

N/ACommissioning completion certificateEvidence that the heating and hot water systems have been commissioned satisfactorily

4.7 Builder’s submission(see schedule below)

Criterion 5: The necessary provisions for energy efficient operation of the dwelling are put in place.5

SAP = 83Has all the relevant information been provided?

N/ABuilder’s submissionO&M instructions5.1

Schedule of supporting competenciesEvidence of competencyTelephoneOrganisation providing evidenceNo.

2.7

2.8

4.6

4.7

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 7: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

DESIGN INPUT & RESULTS

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

SUMMARY OF INPUT DATA FOR DWELLING AS BUILT: Page 1 of 2

Region & Orientation Region: WA Wales (14), House Orientation: S South

60.96, fraction: 0.208.0 Living Area116.23 m2, 99.72 m2, 85.39 m27.0 Internal Floor Area48.30 m, 43.47 m, 41.66 m6.0 Internal Walls Perimeter

5.0 Sunlight/Shade A Average or unknown4.0 Sheltered Sides3.0 Date Built2.0 Number of Storeys1.0 Property Type H House, D Detached

3

22009

2.60 m, 2.45 m, 1.43 m9.0 Average Storey Height9.1 Conservatory None Openings Glazing Type Frame or

Door Type Orientation Air

Gap Uvalue Description Solar

Trans Argon

Fill Area

Double,Low E,Hard Coat Glazed PVC 16 mm 2.50 (T)10.0 Ext. Doors Front Door No0.72 2.07Draught Lobby

Double,Low E,Hard Coat PVC 16 mm 2.00 (T)11.0 Windows Front Elevation No0.72 South (0°) 7.90Double,Low E,Hard Coat PVC 16 mm 2.00 (T)Rear Elevation No0.72 North (180°) 10.86Double,Low E,Hard Coat PVC 16 mm 2.00 (T)Side Elevation No0.72 East (90°) 6.63Double,Low E,Hard Coat PVC 16 mm 2.00 (T)Side Elevation No0.72 West (270°) 13.94Double,Low E,Hard Coat Wood 16 mm 1.30 (M)12.0 Roof Lights Rear Elevation No0.72 North (180°) 2.07Double,Low E,Hard Coat Wood 16 mm 1.30 (M)Side Elevation No0.72 West (270°) 1.75

Openings Average: U: 1.96 Uvalue legend: (T) = Uvalue defaulted from SAP Table (M) = Manufacturer supplied100% 13.0 Draught Proofing

14.0 Thermal Bridging Default - Robust ConstructionThermal Bridges Y 0.080 Description

15.0 Pressure Test (q50)16.0 Mechanical Ventilation None, Windows open during hot weather: Windows fully open

Cross ventilation possible: Yes

Air permeability 8.0 m³/h.m² (as tested)

17.1 Lighting Light fittings: 48, L.E.L. fittings: 40, External lights: Yes, controlled: Yes4, 0, 117.0 Fans, Chimneys, Flues

U - value Room in Roof

Timber Description Shelter Area Curtain Walling

Wall 188.58 No0.25 0.0018.0 Wall Types NoDormer 3.65 Yes0.28 0.00 NoStud Wall to roof Space 4.66 Yes0.32 0.50 NoWall to Porch 3.79 No0.25 0.68 No

Walls uvalue average: U: 0.25Timber or Steel frame area 8.31Roof Ceiling 21.280.1419.0 Plane RoofsCoved Roof 124.810.18

Roofs uvalue average: U: 0.17Ground Floor 116.23 (X) No0.1220.0 Ground Floor Types

Floors uvalue average: U: 0.1220.1 Thermal Mass Simple Thermal Mass Parameter calculation: 19.00

Ground Floor Mass: Medium - solid floorExternal Wall Mass: High - masonry walls (cavity fill or external insulation) with dense plasterSeparating Wall Mass: High - masonry walls dense plasterInternal Partition Mass: High - masonry internal walls with dense plaster

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 8: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

DESIGN INPUT & RESULTS

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

SUMMARY OF INPUT DATA FOR DWELLING AS BUILT: Page 2 of 2

20.2 Fixed Air Conditioning NoBOD Oil condensing, Pumped: pump in heated spaceMain Heating21.0

Heating Controls CBI Time and temperature zone controlBoiler interlock - Yes

Manufacturer & Model Grant, Vortex, Utility System 15-26S, 95.00%Database: 95.0%MHS Efficiency

Underfloor Heating NoneSecondary Heating Manufacturer's data: Vision 500, Tested to BS EN 13229, HETAS approved

clearview Stoves, Efficiency: 65.2%SHS Details 21.1

22.0 HWP From the primary heating systemHot Water HeatingSolar panel: Yes, aperture area: 2.80 m2, Type: TE Evacuated tubeCollector zero-loss efficiency: 0.60Collector heat loss coefficient: 3.00Solar panel ratio A/G: 0.72Orientation: West, Elevation: 45°, Overshading: None or little (< 20%)Solar powered pump, Dedicated solar store volume: 150 litres (separate store)

Solar Water Heating

24.023.0 Thermal Store None

Hot Water Cylinder Yes, in heated space, With statWater heating separately timed: Yes

25.0

Foam, Thickness: 50 mm, Pipes insulatedInsulation300.00 litres, Cylinder contains dedicated solar storageVolume

Community Heating NoneCHP Unit

S - Standard26.0 Electricity TariffNone27.0 Photovoltaic Unit027.1 Micro Wind Turbines Count

27.2 Small-scale Hydro electricity 0.00

None28.0 Special Features

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 9: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Full SAP Calculation Printout

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 1

SAP2005 - 9.81 input data (DesignData) -

Regs Region: EnglandCalculation Type: NewDwellingAsBuiltRegion: WA Wales (14)Orientation: S SouthPropType: H House, D DetachedStoreys: 3Property Age: 2009Sheltered Sides: 2Sunlight Shade: A Average or unknownWall Perimeter: 48.30 m, 43.47 m, 41.66 mFloor Area: 116.23 m2, 99.72 m2, 85.39 m2Living Floor Area: 60.96 m2, fraction:0.00Storey Height: 2.60 m, 2.45 m, 1.43 mConservatory: NoneDoors Front Door: Double,Low E,Hard Coat, Glazed PVC, 16 mm, uvalue: 2.50 (T), area: 2.07 m2, argon: No, solar trans: 0.72Windows Front Elevation: Double,Low E,Hard Coat, PVC, 16 mm, South (0°), uvalue: 2.00 (T), area: 7.90 m2, argon: No, solar trans: 0.72 Rear Elevation: Double,Low E,Hard Coat, PVC, 16 mm, North (180°), uvalue: 2.00 (T), area: 10.86 m2, argon: No, solar trans: 0.72 Side Elevation: Double,Low E,Hard Coat, PVC, 16 mm, East (90°), uvalue: 2.00 (T), area: 6.63 m2, argon: No, solar trans: 0.72 Side Elevation: Double,Low E,Hard Coat, PVC, 16 mm, West (270°), uvalue: 2.00 (T), area: 13.94 m2, argon: No, solar trans: 0.72Draught Lobby: YesDraught Proofing: 100%Roof Lights Rear Elevation: Double,Low E,Hard Coat, Wood, 16 mm, North (180°), uvalue: 1.30 (M), area: 2.07 m2, argon: No, solar trans: 0.72 Side Elevation: Double,Low E,Hard Coat, Wood, 16 mm, West (270°), uvalue: 1.30 (M), area: 1.75 m2, argon: No, solar trans: 0.72Pressure Test: Air permeability 8.0 m³/h.m² (as tested)Mechanical Ventilation: None, Windows open during hot weather: Windows fully open Cross ventilation possible: YesFans, Chimneys, Flues: 4, 0, 1Lighting: Light fittings: 48, L.E.L. fittings: 40, External lights: Yes, controlled: YesMain Wall Type: U: 0.25 A: 188.58 m2Extented Wall Types: U: 0.28 A: 3.65 m2, U: 0.28 A: 4.66 m2, U: 0.21 A: 3.79 m2Timber Frame Wall Area: 8.31Roof Ceiling U: 0.14 A: 21.28 m2Coved Roof U: 0.18 A: 124.81 m2Main Floor Type: U: 0.12 A: 116.23 m2Thermal Mass: Simple Thermal Mass Parameter calculation: 19.00 Ground Floor Mass: Medium - solid floor External Wall Mass: High - masonry walls (cavity fill or external insulation) with dense plaster Separating Wall Mass: High - masonry walls dense plaster Internal Partition Mass: High - masonry internal walls with dense plasterTimber Floor: No Timber FloorFixed Air Conditioning: NoMain Heating: BOD Oil condensing, Pumped: pump in heated spaceMain Heating Manufacturer: Grant, Vortex, Utility System 15-26S, 95.00%

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 10: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 2Heating Controls: CBI Time and temperature zone control Boiler interlock - YesUnderfloor Heating: NoneSecondary Heating: Manufacturer's data: Vision 500, Tested to BS EN 13229, HETAS approvedManufacturer: clearview Stoves, Efficiency: 65.2%Thermal Store: NoneHot Water Heating: HWP From the primary heating systemSolar Water Heating: Solar panel: Yes, aperture area: 2.80 m2, Type: TE Evacuated tube Collector zero-loss efficiency: 0.60 Collector heat loss coefficient: 3.00 Solar panel ratio A/G: 0.72 Orientation: West, Elevation: 45°, Overshading: None or little (< 20%) Solar powered pump, Dedicated solar store volume: 150 litres (separate store)Thermal Store: NoneHot Water Cylinder: Yes, in heated space, With stat Water heating separately timed: YesHot Water Cylinder Insulation: Foam, Thickness: 50 mm, Pipes insulatedHot Water Cylinder Volume: 300.00 litres, Cylinder contains dedicated solar storageCommunity Heating: NoneCHP Unit:Electricity Tariff: S - StandardThermal Bridges: DefaultRobustConstr, Thermal bridging factor y = 0.08PV Cells: NoneEnergy Saved:Energy Used:Terrain Type: UrbanNumber of Wind Turbines: 0

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 11: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 3

SAP calculation (New Dwelling as Built)

1. Overall dwelling dimensionsGround floor 116.230 * 2.600 302.1980First floor 99.720 * 2.450 244.3140Second floor 85.390 * 1.430 122.1077Total floor area 301.340 (5)Total house volume 668.6197 (6)

2. Ventilation rateNumber of chimneys 0 * 40 0 (7)Number of flues 1 * 20 20 (8)Number of fans 4 * 10 40 (9)Flueless gas fire 0 * 40 0 (9a)Infiltration 0.0897 (10)

Pressure test value 8.0100 (q50)Infiltration rate 0.4902 (19)

Sides sheltered 2 (20)Shelter factor 0.8500 (21)Adjusted infiltration rate 0.4167 (22)Air change natural ventilation 0.5868 (24)Effective air change rate 0.5868 (25)

3. Heat losses and heat loss parameterFront Door 2.0700 * 2.50 5.1750 (26)

Windows Front Elevation 7.9000 * (2.00) 1.85 14.6296 (27)Windows Rear Elevation 10.8600 * (2.00) 1.85 20.1111 (27)Windows Side Elevation 6.6300 * (2.00) 1.85 12.2778 (27)Windows Side Elevation 13.9400 * (2.00) 1.85 25.8148 (27)

Roof windows Rear Elevation 2.0700 * (1.30) 1.24 2.5580 (27)Roof windows Side Elevation 1.7500 * (1.30) 1.24 2.1625 (27)

Ground Floor 116.2300 * 0.12 13.9476 (28)

Wall 188.5800 * 0.25 47.1450 (29)Walls Dormer 3.6500 * 0.28 1.0220 (29)Stud Wall to roof Space 4.6600 * (0.32) 0.28 1.2855 (29)Wall to Porch 3.7900 * (0.25) 0.21 0.8098 (29)

Roof Ceiling 21.2800 * 0.14 2.9792 (30)Coved Roof 124.8100 * 0.18 22.4658 (30)

Total area of elements 508.2200 (32)Fabric heat loss 172.3838 (33)Appendix K: Thermal bridging 0.0800 (y)Effect of thermal bridges 40.6576 (34)Total fabric heat loss 213.0414 (35)Ventilation heat loss 129.4786 (36)Heat loss coefficient 342.5200 (37)Heat loss parameter (HLP) 1.1367 (38)

4. Water heating energy requirementsEnergy content of heated water 3908.2048 (39)Distribution loss 689.6832 (40)Cylinder volume 300.0000 (43)Cylinder loss factor (kWh/litre/day) 0.0152 (44)Volume factor from Table 2a 0.7368 (44a)Temperature factor from Table 2b 0.5400 (44b)Energy lost from water storage, kWh/year 661.5784 (45)

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 12: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 4Energy lost from cylinder in kWh/year 330.7892 (47)Primary circuit loss 360.0000 (48)Aperture area of solar collector 2.8000 (H1)Zero-loss collector efficiency 0.6000 (H2)Collector heat loss coefficient 3.0000 (H3)Collector performance ratio 5.0000 (H4)Annual solar radiation per m2 829.0000 (H5)Overshading factor 1.0000 (H6)Solar energy available 1392.7200 (H7)Solar-to-load ratio 0.3029 (H8)Utilisation factor 0.9632 (H9)Collector performance factor 0.7150 (H10)Dedicated solar storage volume 150.0000 (H11)Total volume of cylinder 300.0000 (H12)Effective solar volume 195.0000 (H13)Daily hot water demand 215.4070 (H14)Volume ratio Veff/V 0.9053 (H15)Solar storage volume factor 0.9801 (H16)Solar input 940.0250 (H17)Solar input -940.0250 (50)Output from water heater 4348.6522 (51)Gains from water heating 2081.4291 (52)

5. Internal gainsLighting, appliances, cooking and metabolic (Table 5) 1359.7691 (53)Reduction of internal gains due to LE lighting (Appendix L)Correction factor for low-energy outlets 0.5850 (C1)Window 1 0.9 * 7.900 * 0.80 * 0.7 * 0.83 / 301.340 0.0110Window 2 0.9 * 10.860 * 0.80 * 0.7 * 0.83 / 301.340 0.0151Window 3 0.9 * 6.630 * 0.80 * 0.7 * 0.83 / 301.340 0.0092Window 4 0.9 * 13.940 * 0.80 * 0.7 * 0.83 / 301.340 0.0194Rooflight 1 0.9 * 2.070 * 0.80 * 0.7 * 1.00 / 301.340 0.0035Rooflight 2 0.9 * 1.750 * 0.80 * 0.7 * 1.00 / 301.340 0.0029Ratio of glass area to floor area 0.0610 (GL)Correction factor for daylighting 1.0209 (C2)Annual energy used for lighting in the house 1673.7748 (EL)Reduction in lighting use due to low energy lights 1187.3787 (deltaEL)Low energy lighting -178.1068 (53a)Additional gains - central heating pump 10.0000Additional gains (Table 5a) 10.0000 (53b)Water heating 237.6061 (54)Total internal gains 1429.2684 (55)

6. Solar gains Area Flux g FF Access Gains (m2) Factor (W)Windows 'S ' 0.9 * 7.9000 * 72 * 0.72 * 0.7000 * 0.77 198.6659 (60)Windows (1) 'N ' 0.9 * 10.8600 * 29 * 0.72 * 0.7000 * 0.77 109.9997 (56)Windows (2) 'E ' 0.9 * 6.6300 * 48 * 0.72 * 0.7000 * 0.77 111.1523 (58)Windows (3) 'W ' 0.9 * 13.9400 * 48 * 0.72 * 0.7000 * 0.77 233.7049 (62)Roof windows 'N ' 0.9 * 2.0700 * 29 * 0.72 * 0.7000 * 1.00 27.2296 (64)Roof windows (1) 'W '0.9 * 1.7500 * 48 * 0.72 * 0.7000 * 1.00 38.1024 (64)Total solar gains 718.8548 (65)Total gains, W 2148.1232 (66)Gains/loss ratio (GLR) 6.2715 (67)Utilisation factor 0.9433 (68)Useful gains, W 2026.3410 (69)

7. Mean internal temperatureMean internal temperature of living zone (heating type = 1) 18.8800 (70)Temperature addjustment 0.0000 (71)Adjustment for gains 0.3832 (72)Adjusted room temperature 19.2632 (73)Temperature difference between zones 1.7965 (74)Living area fraction 0.2023 (75)

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 13: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 5Rest of house floor fraction 0.7977 (76)Mean internal temperature 17.8302 (77)

8. Degree-daysTemperature raise from gains 5.9160 (78)Base temperature 11.9142 (79)Degree days 1326.9762 (80)

9a. Energy requirements - individual heating systems, including Micro CHPSpace heating requirement (useful) 10908.3829 (81)Fraction of heat from secondary system 0.1000 (82)Database boiler reference number : 9734Model name : VortexManufacturer: Grant EngineeringMHS efficiency 95.0000Main system efficiency 95.0000 (83)Test Method : BS EN 13229Model name : Vision 500Manufacturer: clearview StovesSecondary system efficiency 65.2000 (84)Space heating fuel - main HS 10334.2575 (85)Space heating fuel - secondary HS 1673.0649 (85a)Efficiency of water heater 95.0000 (86) (from SEDBUK database)Energy required for water heating 4348.6522Energy used for water heating 4577.5287 (86a)For each central heating pump 230.0000 (87a)Electricity for pumps and fans 230.0000 (87)Electricity for pumps and fans - total 230.0000Electricity for lighting (83% fixed LEL) 1673.7748 (87g)

10a. Fuel costs - individual heating systemsMHS heating cost 10334.2575 * 2.1700 224.2534 (88)SHS heating cost 1673.0649 * 2.2000 36.8074 (89)Water heating cost 4577.5287 * 2.1700 99.3324 (91)Pump/fan energy 230.0000 * 7.1200 16.3760 (92)Lighting energy 1673.7748 * 7.1200 119.1728 (93)Additional standing charges 0.0000 (94)-----------------------------------------------------------------------------Total energy cost 495.9420 (97)Total energy cost using Sedbuk db prices 873.2206

11a. SAP ratingEnergy cost deflator 0.9100 (98)Energy cost factor (ECF) 1.2165 (99)ECF unrounded = 1.21645543992808SAP value 83.0183 (99a)SAP value unrounded = 83.018282058604SAP Energy rating 83 (100)SAP Energy rating band B

12a. Carbon dioxide emissionsMHS heating CO2 - box (85) 10334.2575 * 0.2650 2738.5782 (101)SHS heating CO2 - box (85a) 1673.0649 * 0.0250 41.8266 (102)WHS heating CO2 - box (86a) 4577.5287 * 0.2650 1213.0451 (103)Space and water heating CO2 3993.4500 (107)Pumps and fans CO2 - box (87) 230.0000 * 0.4220 97.0600 (108)Electricity for lighting 1673.7748 * 0.4220 706.3330 (109)Total CO2 emissions in kg/year 4796.8429 (112)CO2 emissions per m? 15.9184Dwelling's Carbon Factor 13.8501 (CF)EI value 81.4409 (113a)EI rating 81 (114)EI band B

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 14: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 6

13a. Primary energyMHS heating P.E. - box (85) 10334.2575 * 1.1900 12297.7664SHS heating P.E. - box (85a) 1673.0649 * 1.1000 1840.3713WHS heating P.E. - box (86a) 4577.5287 * 1.1900 5447.2591Space and water heating P.E. 19585.3969 (107)Pumps and fans P.E. - box (87) 230.0000 * 2.8000 644.0000 (108)Electricity for lighting 1673.7748 * 2.8000 4686.5695 (109)Primary energy kWh/year 24915.9663 (112)Primary energy kWh/m2/year 82.6839

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 15: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 7

DER calculation (New Dwelling as Built)

1. Overall dwelling dimensionsGround floor 116.230 * 2.600 302.1980First floor 99.720 * 2.450 244.3140Second floor 85.390 * 1.430 122.1077Total floor area 301.340 (5)Total house volume 668.6197 (6)

2. Ventilation rateNumber of chimneys 0 * 40 0 (7)Number of flues 1 * 20 20 (8)Number of fans 4 * 10 40 (9)Flueless gas fire 0 * 40 0 (9a)Infiltration 0.0897 (10)

Pressure test value 8.0100 (q50)Infiltration rate 0.4902 (19)

Sides sheltered 2 (20)Shelter factor 0.8500 (21)Adjusted infiltration rate 0.4167 (22)Air change natural ventilation 0.5868 (24)Effective air change rate 0.5868 (25)

3. Heat losses and heat loss parameterFront Door 2.0700 * 2.50 5.1750 (26)

Windows Front Elevation 7.9000 * (2.00) 1.85 14.6296 (27)Windows Rear Elevation 10.8600 * (2.00) 1.85 20.1111 (27)Windows Side Elevation 6.6300 * (2.00) 1.85 12.2778 (27)Windows Side Elevation 13.9400 * (2.00) 1.85 25.8148 (27)

Roof windows Rear Elevation 2.0700 * (1.30) 1.24 2.5580 (27)Roof windows Side Elevation 1.7500 * (1.30) 1.24 2.1625 (27)

Ground Floor 116.2300 * 0.12 13.9476 (28)

Wall 188.5800 * 0.25 47.1450 (29)Walls Dormer 3.6500 * 0.28 1.0220 (29)Stud Wall to roof Space 4.6600 * (0.32) 0.28 1.2855 (29)Wall to Porch 3.7900 * (0.25) 0.21 0.8098 (29)

Roof Ceiling 21.2800 * 0.14 2.9792 (30)Coved Roof 124.8100 * 0.18 22.4658 (30)

Total area of elements 508.2200 (32)Fabric heat loss 172.3838 (33)Appendix K: Thermal bridging 0.0800 (y)Effect of thermal bridges 40.6576 (34)Total fabric heat loss 213.0414 (35)Ventilation heat loss 129.4786 (36)Heat loss coefficient 342.5200 (37)Heat loss parameter (HLP) 1.1367 (38)

4. Water heating energy requirementsEnergy content of heated water 3908.2048 (39)Distribution loss 689.6832 (40)Cylinder volume 300.0000 (43)Cylinder loss factor (kWh/litre/day) 0.0152 (44)Volume factor from Table 2a 0.7368 (44a)Temperature factor from Table 2b 0.5400 (44b)Energy lost from water storage, kWh/year 661.5784 (45)

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 16: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 8Energy lost from cylinder in kWh/year 330.7892 (47)Primary circuit loss 360.0000 (48)Aperture area of solar collector 2.8000 (H1)Zero-loss collector efficiency 0.6000 (H2)Collector heat loss coefficient 3.0000 (H3)Collector performance ratio 5.0000 (H4)Annual solar radiation per m2 829.0000 (H5)Overshading factor 1.0000 (H6)Solar energy available 1392.7200 (H7)Solar-to-load ratio 0.3029 (H8)Utilisation factor 0.9632 (H9)Collector performance factor 0.7150 (H10)Dedicated solar storage volume 150.0000 (H11)Total volume of cylinder 300.0000 (H12)Effective solar volume 195.0000 (H13)Daily hot water demand 215.4070 (H14)Volume ratio Veff/V 0.9053 (H15)Solar storage volume factor 0.9801 (H16)Solar input 940.0250 (H17)Solar input -940.0250 (50)Output from water heater 4348.6522 (51)Gains from water heating 2081.4291 (52)

5. Internal gainsLighting, appliances, cooking and metabolic (Table 5) 1359.7691 (53)Reduction of internal gains due to LE lighting (Appendix L)Correction factor for low-energy outlets 0.8500 (C1)Window 1 0.9 * 7.900 * 0.80 * 0.7 * 0.83 / 301.340 0.0110Window 2 0.9 * 10.860 * 0.80 * 0.7 * 0.83 / 301.340 0.0151Window 3 0.9 * 6.630 * 0.80 * 0.7 * 0.83 / 301.340 0.0092Window 4 0.9 * 13.940 * 0.80 * 0.7 * 0.83 / 301.340 0.0194Rooflight 1 0.9 * 2.070 * 0.80 * 0.7 * 1.00 / 301.340 0.0035Rooflight 2 0.9 * 1.750 * 0.80 * 0.7 * 1.00 / 301.340 0.0029Ratio of glass area to floor area 0.0610 (GL)Correction factor for daylighting 1.0209 (C2)Annual energy used for lighting in the house 2431.9805 (EL)Reduction in lighting use due to low energy lights 429.1730 (deltaEL)Low energy lighting -64.3760 (53a)Additional gains - central heating pump 10.0000Additional gains (Table 5a) 10.0000 (53b)Water heating 237.6061 (54)Total internal gains 1542.9992 (55)

6. Solar gains Area Flux g FF Access Gains (m2) Factor (W)Windows 'S ' 0.9 * 7.9000 * 72 * 0.72 * 0.7000 * 0.77 198.6659 (60)Windows (1) 'N ' 0.9 * 10.8600 * 29 * 0.72 * 0.7000 * 0.77 109.9997 (56)Windows (2) 'E ' 0.9 * 6.6300 * 48 * 0.72 * 0.7000 * 0.77 111.1523 (58)Windows (3) 'W ' 0.9 * 13.9400 * 48 * 0.72 * 0.7000 * 0.77 233.7049 (62)Roof windows 'N ' 0.9 * 2.0700 * 29 * 0.72 * 0.7000 * 1.00 27.2296 (64)Roof windows (1) 'W '0.9 * 1.7500 * 48 * 0.72 * 0.7000 * 1.00 38.1024 (64)Total solar gains 718.8548 (65)Total gains, W 2261.8541 (66)Gains/loss ratio (GLR) 6.6036 (67)Utilisation factor 0.9345 (68)Useful gains, W 2113.7166 (69)

7. Mean internal temperatureMean internal temperature of living zone (heating type = 1) 18.8800 (70)Temperature addjustment 0.0000 (71)Adjustment for gains 0.4342 (72)Adjusted room temperature 19.3142 (73)Temperature difference between zones 1.7965 (74)Living area fraction 0.2023 (75)

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 17: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 9Rest of house floor fraction 0.7977 (76)Mean internal temperature 17.8812 (77)

8. Degree-daysTemperature raise from gains 6.1711 (78)Base temperature 11.7101 (79)Degree days 1284.1200 (80)

9a. Energy requirements - individual heating systems, including Micro CHPSpace heating requirement (useful) 10556.0842 (81)Fraction of heat from secondary system 0.1000 (82)Database boiler reference number : 9734Model name : VortexManufacturer: Grant EngineeringMHS efficiency 95.0000Main system efficiency 95.0000 (83)Test Method : BS EN 13229Model name : Vision 500Manufacturer: clearview StovesSecondary system efficiency 65.2000 (84)Space heating fuel - main HS 10000.5008 (85)Space heating fuel - secondary HS 1619.0313 (85a)Efficiency of water heater 95.0000 (86) (from SEDBUK database)Energy required for water heating 4348.6522Energy used for water heating 4577.5287 (86a)For each central heating pump 230.0000 (87a)Electricity for pumps and fans 230.0000 (87)Electricity for pumps and fans - total 230.0000Electricity for lighting (30% fixed LEL) 2431.9805 (87g)

12a. Carbon dioxide emissionsMHS heating CO2 - box (85) 10000.5008 * 0.2650 2650.1327 (101)SHS heating CO2 - box (85a) 1619.0313 * 0.0250 40.4758 (102)WHS heating CO2 - box (86a) 4577.5287 * 0.2650 1213.0451 (103)Space and water heating CO2 3903.6536 (107)Pumps and fans CO2 - box (87) 230.0000 * 0.4220 97.0600 (108)Electricity for lighting 2431.9805 * 0.4220 1026.2958 (109)Total CO2 emissions in kg/year 5027.0094 (112)CO2 emissions per m? 16.6822

Dwelling's Carbon Emission Rate (DER) - orientation: S 16.6822 (113)

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 18: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 10

TER calculation (New Dwelling as Built)

1. Overall dwelling dimensionsGround floor 116.230 * 2.600 302.1980First floor 99.720 * 2.450 244.3140Second floor 85.390 * 1.430 122.1077Total floor area 301.340 (5)Total house volume 668.6197 (6)

2. Ventilation rateNumber of chimneys 0 * 40 0 (7)Number of flues 0 * 20 0 (8)Number of fans 3 * 10 30 (9)Flueless gas fire 0 * 40 0 (9a)Infiltration 0.0449 (10)

Pressure test value 10.0000 (q50)Infiltration rate 0.5449 (19)

Sides sheltered 2 (20)Shelter factor 0.8500 (21)Adjusted infiltration rate 0.4631 (22)Air change natural ventilation 0.6072 (24)Effective air change rate 0.6072 (25)

3. Heat losses and heat loss parameterOne opaque door 1.8500 * 2.00 3.7000 (26)

Windows Double glazed, low-E 73.4850 * (2.00) 1.85 136.0833 (27)

Ground Floor 116.2300 * 0.25 29.0575 (28)

Wall 166.7450 * 0.35 58.3608 (29)

Roof Ceiling 25.1000 * 0.16 4.0160 (30)Coved Roof 124.8100 * 0.16 19.9696 (30)

Total area of elements 508.2200 (32)Fabric heat loss 251.1872 (33)Appendix K: Thermal bridging 0.1100 (y)Effect of thermal bridges 55.9042 (34)Total fabric heat loss 307.0914 (35)Ventilation heat loss 133.9860 (36)Heat loss coefficient 441.0774 (37)Heat loss parameter (HLP) 1.4637 (38)

4. Water heating energy requirementsEnergy content of heated water 3908.2048 (39)Distribution loss 689.6832 (40)Cylinder volume 150.0000 (43)Cylinder loss factor (kWh/litre/day) 0.0191 (44)Volume factor from Table 2a 0.9283 (44a)Temperature factor from Table 2b 0.5400 (44b)Energy lost from water storage, kWh/year 524.2835 (45)Energy lost from cylinder in kWh/year 524.2835 (47)Primary circuit loss 610.0000 (48)Output from water heater 5732.1716 (51)Gains from water heating 2436.2246 (52)

5. Internal gainsLighting, appliances, cooking and metabolic (Table 5) 1359.7691 (53)Reduction of internal gains due to LE lighting (Appendix L)

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 19: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 11Correction factor for low-energy outlets 0.8500 (C1)Window 1 0.9 * 73.485 * 0.80 * 0.7 * 0.83 / 301.340 0.1020Ratio of glass area to floor area 0.1020 (GL)Correction factor for daylighting 0.9600 (C2)Annual energy used for lighting in the house 2286.8090 (EL)Reduction in lighting use due to low energy lights 403.5545 (deltaEL)Low energy lighting -60.5332 (53a)Additional gains - central heating pump 10.0000Additional gains (Table 5a) 10.0000 (53b)Water heating 278.1078 (54)Total internal gains 1587.3438 (55)

6. Solar gains Area Flux g FF Access Gains (m2) Factor (W)Windows 'E ' 0.9 * 73.4850 * 48 * 0.72 * 0.7000 * 0.77 1231.9801 (58)Total solar gains 1231.9801 (65)Total gains, W 2819.3239 (66)Gains/loss ratio (GLR) 6.3919 (67)Utilisation factor 0.9402 (68)Useful gains, W 2650.6125 (69)

7. Mean internal temperatureMean internal temperature of living zone (heating type = 1) 18.8800 (70)Temperature addjustment 0.0000 (71)Adjustment for gains 0.4019 (72)Adjusted room temperature 19.2819 (73)Temperature difference between zones 1.4842 (74)Living area fraction 0.2023 (75)Rest of house floor fraction 0.7977 (76)Mean internal temperature 18.0979 (77)

8. Degree-daysTemperature raise from gains 6.0094 (78)Base temperature 12.0885 (79)Degree days 1363.5911 (80)

9a. Energy requirements - individual heating systems, including Micro CHPSpace heating requirement (useful) 14434.7818 (81)Fraction of heat from secondary system 0.1000 (82)Test Method :Model name : AnyManufacturer: AnyMHS efficiency 78.0000Main system efficiency 78.0000 (83)Secondary system efficiency 100.0000 (84)Space heating fuel - main HS 16655.5174 (85)Space heating fuel - secondary HS 1443.4782 (85a)Efficiency of water heater 78.0000 (86)Energy required for water heating 5732.1716Energy used for water heating 7348.9379 (86a)For each central heating pump 130.0000 (87a)For each boiler with F.A.F 45.0000 (87b)Electricity for pumps and fans 175.0000 (87)Electricity for pumps and fans - total 175.0000Electricity for lighting (30% fixed LEL) 2286.8090 (87g)

12a. Carbon dioxide emissionsMHS heating CO2 - box (85) 16655.5174 * 0.1940 3231.1704 (101)SHS heating CO2 - box (85a) 1443.4782 * 0.4220 609.1478 (102)WHS heating CO2 - box (86a) 7348.9379 * 0.1940 1425.6940 (103)Space and water heating CO2 5266.0121 (107)Pumps and fans CO2 - box (87) 175.0000 * 0.4220 73.8500 (108)Electricity for lighting 2286.8090 * 0.4220 965.0334 (109)

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 20: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 12Total CO2 emissions in kg/year 6304.8955 (112)CO2 emissions per m? 20.9229

CO2 for heating and hot water 5339.8621 (CH)CO2 emissions from internal lighting 965.0334 (CL)ADL1A - Table 1 Fuel factor 1.1700 (FuelFactor)Level of reduction in CO2 - Improvement factor 20 (%)Total floor area 301.3400 (TFA)Target Carbon Dioxide Emission Rate (TER) 19.1483 (113)

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 21: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 13

Regulation compliance checklist

1 TER and DER OK1.1 Target Carbon Dioxide Emission RateMain fuel - Oil, Fuel factor = 1.17, TER = 19.151.2 Dwelling Carbon Dioxide Emission Rate - DER = 16.681.3 DER 16.68 < TER 19.15

2.1 Fabric U-values OKWall 0.25 (0.35) 0.28 (0.70) OKRoof 0.17 (0.25) 0.18 (0.35) OKFloor 0.12 (0.25) 0.12 (0.70) OKOpenings 1.96 (2.20) 2.50 (3.30) OK

2.3 Heating efficiency OKOil condensing, Pumped: pump in heated spaceEfficiency - Database: 95.0%Minimum permitted: 85.0% - OKSecondary heating: Manufacturer's data: Vision 500, Tested to BS EN 13229, HETAS approvedManufacturer: clearview Stoves, Efficiency: 65.2%Minimum permitted: 65.0% - OK

2.4 Cylinder insulation OKVolume = 300 litresNominal cylinder loss: 3.36 kWh/dayPermitted by DHCG: 3.98 kWh/day - OKPrimary pipework insulated: Yes - OK

2.5 Controls OKTime and temperature zone control - OKCylinder thermostat - OK, Separate water control - OK

2.7 Low energy lighting OKLight fittings: 48, L.E.L. fittings: 40 = 83.00% > 25% - OKL.E.L. fittings required per 25m2 or part of TFA: 13 < 40 - OK

2.8 External lighting OKExternal lights: Yes, controlled: Yes

3.1 Summertime temperature OKRegion: Wales (14)Thermal mass parameter = 19.0Ventilation rate in hot weather = 8.0Overheating risk (Orientation 'S') = Not significant - OK

4.1 Key featuresWall U-value 0.25 < 0.28Floor U-value 0.12 < 0.20Wall U-value 0.21 < 0.28Roof U-value 0.14 < 0.15Boiler efficiency 95.0% (> 89.0%)Openings U-value 1.30 < 1.80Solar panel

4.5 Design air permeability OKActual air permeability = 8.0

Overall result: OK

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 22: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 14

Recommendation Level E

E Low energy lighting : 100% Recommendation result : RecommendedE Recommendation no : 35E Recommendation text : Low energy lighting for all fixed outlets CO2 emissions : 4723.627 (change = -73.216) Total energy cost (97) : 481.388 (change = 14.554) Total energy cost (Sedbuk) : 851.125 (change = -22.095) SAP rating : 84 (value = 83.552) EI rating : 82 (value = 81.724)E Recommendation : SAP change (83.552 - 83.018), increase = 0.534

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 23: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 15

Recommendation Level N

Recommendation result : AlreadyInstalledN Recommendation text : Solar panel recommendation

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 24: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 16

Recommendation Level U

U Photovoltaics : 2.5 kWp Recommendation result : RecommendedU Recommendation no : 34U Recommendation text : Solar photovoltaic panels, 2.5 kWp CO2 emissions : 3776.657 (change = -946.970) Total energy cost (97) : 374.520 (change = 106.868) Total energy cost (Sedbuk) : 683.822 (change = -167.304) SAP rating : 87 (value = 87.472) EI rating : 85 (value = 85.388)U Recommendation : SAP change (87.472 - 83.552), increase = 3.920

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 25: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 17

Recommendation Level

V Wind turbine : blade diameter 1.75 m Recommendation result : RecommendedV Recommendation no : 44V Recommendation text : Wind turbine CO2 emissions : 3749.898 (change = -26.759) Total energy cost (97) : 371.367 (change = 3.154) Total energy cost (Sedbuk) : 678.884 (change = -4.938) SAP rating : 88 (value = 87.588) EI rating : 85 (value = 85.492)V Recommendation : SAP change (87.588 - 87.472), increase = 0.116 EffectTooSmall

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 26: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 18

Recommendation Total

E Low energy lighting : 100%U Photovoltaics : 2.5 kWp

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 27: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 19

SAP2005 - 9.81 input data (DesignData) -

Regs Region: EnglandCalculation Type: NewDwellingAsBuiltRegion: WA Wales (14)Orientation: S SouthPropType: H House, D DetachedStoreys: 3Property Age: 2009Sheltered Sides: 2Sunlight Shade: A Average or unknownWall Perimeter: 48.30 m, 43.47 m, 41.66 mFloor Area: 116.23 m2, 99.72 m2, 85.39 m2Living Floor Area: 60.96 m2, fraction:0.20Storey Height: 2.60 m, 2.45 m, 1.43 mConservatory: NoneDoors Front Door: Double,Low E,Hard Coat, Glazed PVC, 16 mm, uvalue: 2.50 (T), area: 2.07 m2, argon: No, solar trans: 0.72Windows Front Elevation: Double,Low E,Hard Coat, PVC, 16 mm, South (0°), uvalue: 2.00 (T), area: 7.90 m2, argon: No, solar trans: 0.72 Rear Elevation: Double,Low E,Hard Coat, PVC, 16 mm, North (180°), uvalue: 2.00 (T), area: 10.86 m2, argon: No, solar trans: 0.72 Side Elevation: Double,Low E,Hard Coat, PVC, 16 mm, East (90°), uvalue: 2.00 (T), area: 6.63 m2, argon: No, solar trans: 0.72 Side Elevation: Double,Low E,Hard Coat, PVC, 16 mm, West (270°), uvalue: 2.00 (T), area: 13.94 m2, argon: No, solar trans: 0.72Draught Lobby: YesDraught Proofing: 100%Roof Lights Rear Elevation: Double,Low E,Hard Coat, Wood, 16 mm, North (180°), uvalue: 1.30 (M), area: 2.07 m2, argon: No, solar trans: 0.72 Side Elevation: Double,Low E,Hard Coat, Wood, 16 mm, West (270°), uvalue: 1.30 (M), area: 1.75 m2, argon: No, solar trans: 0.72Pressure Test: Air permeability 8.0 m³/h.m² (as tested)Mechanical Ventilation: None, Windows open during hot weather: Windows fully open Cross ventilation possible: YesFans, Chimneys, Flues: 4, 0, 1Lighting: Light fittings: 48, L.E.L. fittings: 48, External lights: Yes, controlled: YesMain Wall Type: U: 0.25 A: 188.58 m2Extented Wall Types: U: 0.28 A: 3.65 m2, U: 0.28 A: 4.66 m2, U: 0.21 A: 3.79 m2Timber Frame Wall Area: 8.31Roof Ceiling U: 0.14 A: 21.28 m2Coved Roof U: 0.18 A: 124.81 m2Main Floor Type: U: 0.12 A: 116.23 m2Thermal Mass: Simple Thermal Mass Parameter calculation: 19.00 Ground Floor Mass: Medium - solid floor External Wall Mass: High - masonry walls (cavity fill or external insulation) with dense plaster Separating Wall Mass: High - masonry walls dense plaster Internal Partition Mass: High - masonry internal walls with dense plasterTimber Floor: No Timber FloorFixed Air Conditioning: NoMain Heating: BOD Oil condensing, Pumped: pump in heated spaceMain Heating Manufacturer: Grant, Vortex, Utility System 15-26S, 95.00%Heating Controls: CBI Time and temperature zone control Boiler interlock - YesUnderfloor Heating: NoneSecondary Heating: Manufacturer's data: Vision 500, Tested to BS EN 13229, HETAS approvedManufacturer: clearview Stoves, Efficiency: 65.2%Thermal Store: NoneHot Water Heating: HWP From the primary heating systemSolar Water Heating: Solar panel: Yes, aperture area: 2.80 m2, Type: TE Evacuated tube Collector zero-loss efficiency: 0.60 Collector heat loss coefficient: 3.00 Solar panel ratio A/G: 0.72 Orientation: West, Elevation: 45°, Overshading: None or little (< 20%) Solar powered pump, Dedicated solar store volume: 150 litres (separate store)Thermal Store: NoneHot Water Cylinder: Yes, in heated space, With stat Water heating separately timed: Yes

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 28: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 20Hot Water Cylinder Insulation: Foam, Thickness: 50 mm, Pipes insulatedHot Water Cylinder Volume: 300.00 litres, Cylinder contains dedicated solar storageCommunity Heating: NoneCHP Unit:Electricity Tariff: S - StandardThermal Bridges: DefaultRobustConstr, Thermal bridging factor y = 0.08PV Cells: PV cells Peak Power: 2.50 Orientation: South, Elevation: 30°, Overshading: Modest (20% - 60%)Energy Saved:Energy Used:Terrain Type: UrbanNumber of Wind Turbines: 0

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 29: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 21

Recommendations calculation (New Dwelling as Built)

1. Overall dwelling dimensionsGround floor 116.230 * 2.600 302.1980First floor 99.720 * 2.450 244.3140Second floor 85.390 * 1.430 122.1077Total floor area 301.340 (5)Total house volume 668.6197 (6)

2. Ventilation rateNumber of chimneys 0 * 40 0 (7)Number of flues 1 * 20 20 (8)Number of fans 4 * 10 40 (9)Flueless gas fire 0 * 40 0 (9a)Infiltration 0.0897 (10)

Pressure test value 8.0100 (q50)Infiltration rate 0.4902 (19)

Sides sheltered 2 (20)Shelter factor 0.8500 (21)Adjusted infiltration rate 0.4167 (22)Air change natural ventilation 0.5868 (24)Effective air change rate 0.5868 (25)

3. Heat losses and heat loss parameterFront Door 2.0700 * 2.50 5.1750 (26)

Windows Front Elevation 7.9000 * (2.00) 1.85 14.6296 (27)Windows Rear Elevation 10.8600 * (2.00) 1.85 20.1111 (27)Windows Side Elevation 6.6300 * (2.00) 1.85 12.2778 (27)Windows Side Elevation 13.9400 * (2.00) 1.85 25.8148 (27)

Roof windows Rear Elevation 2.0700 * (1.30) 1.24 2.5580 (27)Roof windows Side Elevation 1.7500 * (1.30) 1.24 2.1625 (27)

Ground Floor 116.2300 * 0.12 13.9476 (28)

Wall 188.5800 * 0.25 47.1450 (29)Walls Dormer 3.6500 * 0.28 1.0220 (29)Stud Wall to roof Space 4.6600 * (0.32) 0.28 1.2855 (29)Wall to Porch 3.7900 * (0.25) 0.21 0.8098 (29)

Roof Ceiling 21.2800 * 0.14 2.9792 (30)Coved Roof 124.8100 * 0.18 22.4658 (30)

Total area of elements 508.2200 (32)Fabric heat loss 172.3838 (33)Appendix K: Thermal bridging 0.0800 (y)Effect of thermal bridges 40.6576 (34)Total fabric heat loss 213.0414 (35)Ventilation heat loss 129.4786 (36)Heat loss coefficient 342.5200 (37)Heat loss parameter (HLP) 1.1367 (38)

4. Water heating energy requirementsEnergy content of heated water 3908.2048 (39)Distribution loss 689.6832 (40)Cylinder volume 300.0000 (43)Cylinder loss factor (kWh/litre/day) 0.0152 (44)Volume factor from Table 2a 0.7368 (44a)Temperature factor from Table 2b 0.5400 (44b)Energy lost from water storage, kWh/year 661.5784 (45)

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 30: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 22Energy lost from cylinder in kWh/year 330.7892 (47)Primary circuit loss 360.0000 (48)Aperture area of solar collector 2.8000 (H1)Zero-loss collector efficiency 0.6000 (H2)Collector heat loss coefficient 3.0000 (H3)Collector performance ratio 5.0000 (H4)Annual solar radiation per m2 829.0000 (H5)Overshading factor 1.0000 (H6)Solar energy available 1392.7200 (H7)Solar-to-load ratio 0.3029 (H8)Utilisation factor 0.9632 (H9)Collector performance factor 0.7150 (H10)Dedicated solar storage volume 150.0000 (H11)Total volume of cylinder 300.0000 (H12)Effective solar volume 195.0000 (H13)Daily hot water demand 215.4070 (H14)Volume ratio Veff/V 0.9053 (H15)Solar storage volume factor 0.9801 (H16)Solar input 940.0250 (H17)Solar input -940.0250 (50)Output from water heater 4348.6522 (51)Gains from water heating 2081.4291 (52)

5. Internal gainsLighting, appliances, cooking and metabolic (Table 5) 1359.7691 (53)Low energy lighting -214.5865 (53a)Additional gains - central heating pump 10.0000Additional gains (Table 5a) 10.0000 (53b)Water heating 237.6061 (54)Total internal gains 1392.7887 (55)

6. Solar gains Area Flux g FF Access Gains (m2) Factor (W)Windows 'S ' 0.9 * 7.9000 * 72 * 0.72 * 0.7000 * 0.77 198.6659 (60)Windows (1) 'N ' 0.9 * 10.8600 * 29 * 0.72 * 0.7000 * 0.77 109.9997 (56)Windows (2) 'E ' 0.9 * 6.6300 * 48 * 0.72 * 0.7000 * 0.77 111.1523 (58)Windows (3) 'W ' 0.9 * 13.9400 * 48 * 0.72 * 0.7000 * 0.77 233.7049 (62)Roof windows 'N ' 0.9 * 2.0700 * 29 * 0.72 * 0.7000 * 1.00 27.2296 (64)Roof windows (1) 'W '0.9 * 1.7500 * 48 * 0.72 * 0.7000 * 1.00 38.1024 (64)Total solar gains 718.8548 (65)Total gains, W 2111.6435 (66)Gains/loss ratio (GLR) 6.1650 (67)Utilisation factor 0.9461 (68)Useful gains, W 1997.7204 (69)

7. Mean internal temperatureMean internal temperature of living zone (heating type = 1) 18.8800 (70)Temperature addjustment 0.0000 (71)Adjustment for gains 0.3665 (72)Adjusted room temperature 19.2465 (73)Temperature difference between zones 1.7965 (74)Living area fraction 0.2023 (75)Rest of house floor fraction 0.7977 (76)Mean internal temperature 17.8134 (77)

8. Degree-daysTemperature raise from gains 5.8324 (78)Base temperature 11.9810 (79)Degree days 1341.0141 (80)

9a. Energy requirements - individual heating systems, including Micro CHPSpace heating requirement (useful) 11023.7811 (81)Fraction of heat from secondary system 0.1000 (82)Database boiler reference number : 9734

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 31: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 23Model name : VortexManufacturer: Grant EngineeringMHS efficiency 95.0000Main system efficiency 95.0000 (83)Test Method : BS EN 13229Model name : Vision 500Manufacturer: clearview StovesSecondary system efficiency 65.2000 (84)Space heating fuel - main HS 10443.5821 (85)Space heating fuel - secondary HS 1690.7640 (85a)Efficiency of water heater 95.0000 (86) (from SEDBUK database)Energy required for water heating 4348.6522Energy used for water heating 4577.5287 (86a)For each central heating pump 230.0000 (87a)Electricity for pumps and fans 230.0000 (87)Electricity for pumps and fans - total 230.0000Electricity for lighting (100% fixed LEL) 1430.5768 (87g)

10a. Fuel costs - individual heating systemsMHS heating cost 10443.5821 * 2.1700 226.6257 (88)SHS heating cost 1690.7640 * 2.2000 37.1968 (89)Water heating cost 4577.5287 * 2.1700 99.3324 (91)Pump/fan energy 230.0000 * 7.1200 16.3760 (92)Lighting energy 1430.5768 * 7.1200 101.8571 (93)Additional standing charges 0.0000 (94)Appendix M1: Energy from Photovoltaic (PV) technology -----------------------Effective price depends on a factor 0.5000 (Beta)Normal electricity price 7.1200Exported electricity price 5.7000Effective fuel price 6.4100Photovoltaic energy 0.80 * 2.50 * 1042.0 * 0.80 1667.2000 (95)Produced energy -1667.2000 * 6.4100 -106.8675 (95a)-----------------------------------------------------------------------------Total energy cost 374.5205 (97)Total energy cost using Sedbuk db prices 683.8217

11a. SAP ratingEnergy cost deflator 0.9100 (98)Energy cost factor (ECF) 0.8974 (99)ECF unrounded = 0.897423385841112SAP value 87.4720 (99a)SAP value unrounded = 87.4719695336581SAP Energy rating 87 (100)SAP Energy rating band B

12a. Carbon dioxide emissionsMHS heating CO2 - box (85) 10443.5821 * 0.2650 2767.5493 (101)SHS heating CO2 - box (85a) 1690.7640 * 0.0250 42.2691 (102)WHS heating CO2 - box (86a) 4577.5287 * 0.2650 1213.0451 (103)Space and water heating CO2 4022.8635 (107)Pumps and fans CO2 - box (87) 230.0000 * 0.4220 97.0600 (108)Electricity for lighting 1430.5768 * 0.4220 603.7034 (109)Produced energy - PV - CO2 -1667.2000 * 0.5680 -946.9696 (110)Total CO2 emissions in kg/year 3776.6572 (112)CO2 emissions per m? 12.5329Dwelling's Carbon Factor 10.9045 (CF)EI value 85.3880 (113a)EI rating 85 (114)EI band B

13a. Primary energyMHS heating P.E. - box (85) 10443.5821 * 1.1900 12427.8627SHS heating P.E. - box (85a) 1690.7640 * 1.1000 1859.8404

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 32: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

CALCULATION DETAILS for survey reference no 'A998-0001-09-56' Page: 24WHS heating P.E. - box (86a) 4577.5287 * 1.1900 5447.2591Space and water heating P.E. 19734.9622 (107)Pumps and fans P.E. - box (87) 230.0000 * 2.8000 644.0000 (108)Electricity for lighting 1430.5768 * 2.8000 4005.6149 (109)Produced energy - PV - P.E. -1667.2000 * 2.8000 -4668.1600 (110)Primary energy kWh/year 19716.4171 (112)Primary energy kWh/m2/year 65.4291

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 33: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

UVALUE CALCULATION

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

Building Elements:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Building Element Floor 1 - Slab on the ground floorFloor Type: Slab on groundArea = 116.23 m², Perimeter = 48.30 m, Wall thickness = 300 mm, Soil: UnknownHorizontal edge insulation: noneVertical edge insulation: none

Layer FractionRλThicknessDescriptionExternal surface 0.040Layer1 Concrete, dense

Main construction 100 mm 2.000 100.00 %0.050

Layer2 Expanded polystyreneMain construction 80 mm 0.040 100.00 %2.000

Corrections - Air Gap: Level 0, Fasteners: None or plasticLayer3 Celotex

Main construction 100 mm 0.023 100.00 %4.348Corrections - Air Gap: Level 0, Fasteners: None or plastic

Layer4 ScreedMain construction 75 mm 0.410 100.00 %0.183

Internal surface 0.170 Upper limit = 6.581 m²K/W Lower limit = 6.581 m²K/W Average = 6.581 m²K/WTotal resistance:

U-value (unrounded) = 0.0000 W/m²KSlab on Ground floor corrections:Horizontal delta Psi = -0.0002 Vertical delta Psi = -0.0005 B' = 4.8128 Delta U = -0.00029

U-value: 0.12 W/m²KTotal thickness: 355 mm

Building Element Roof Plane 1 - Pitched roof - insulated ceilingRoof Type: Pitched Roof, insulated flat ceiling

Layer FractionRλThicknessDescriptionExternal surface 0.040Layer1 Mineral wool

Main construction 150 mm 0.040 100.00 %3.750Corrections - Air Gap: Level 0, Fasteners: None or plastic

Layer2 Mineral woolMain construction 150 mm 0.040 91.67 %3.750

Corrections - Air Gap: Level 0, Fasteners: None or plasticBridging - Wood 150 mm 0.130 8.33 %0.000

Layer3 Plasterboard, standardMain construction 13 mm 0.210 100.00 %0.060

Internal surface 0.100 Upper limit = 7.387 m²K/W Lower limit = 7.108 m²K/W Average = 7.247 m²K/WTotal resistance:

U-value (unrounded) = 0.1380 W/m²KUnheated space: None

U-value: 0.14 W/m²KTotal thickness: 313 mm

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 34: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

UVALUE CALCULATION

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

Building Elements:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Building Element Roof Slope 1 - Pitched roof - insulated slope, sloping ceilingRoof Type: Pitched Roof, insulated sloping ceiling

Layer FractionRλThicknessDescriptionExternal surface 0.100Layer1 Tiling, clay

Main construction 15 mm 1.000 100.00 %0.000

Layer2 Standard cavityMain construction 25 mm 0.250 100.00 %0.000

Corrections - Cavity Ventilated, Emissivity: NormalLayer3 Sarking felt

Main construction 1 mm 0.190 100.00 %0.000

Layer4 Standard cavityMain construction 50 mm 0.500 100.00 %0.000

Corrections - Cavity Ventilated, Emissivity: NormalLayer5 Celotex

Main construction 100 mm 0.023 87.50 %4.348Corrections - Air Gap: Level 0, Fasteners: None or plastic

Bridging - Timber 100 mm 0.130 12.50 %0.000Layer6 Celotex

Main construction 50 mm 0.023 100.00 %2.174Corrections - Air Gap: Level 0, Fasteners: None or plastic

Layer7 Plasterboard, standardMain construction 13 mm 0.210 100.00 %0.060

Internal surface 0.100 Upper limit = 5.950 m²K/W Lower limit = 5.183 m²K/W Average = 5.566 m²K/WTotal resistance:

U-value (unrounded) = 0.1796 W/m²KUnheated space: None

U-value: 0.18 W/m²KTotal thickness: 254 mm

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 35: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

UVALUE CALCULATION

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

Building Elements:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Building Element Wall Main - Dense Block with 70 CelotexLayer FractionRλThicknessDescriptionExternal surface 0.040Layer1 Render

Main construction 20 mm 0.570 100.00 %0.035

Layer2 Blockwork, denseMain construction 100 mm 1.590 100.00 %0.063

Layer3 High E CavityMain construction 50 mm 0.075 100.00 %0.665

Layer4 Tuff-RTM Zero GA3000ZMain construction 70 mm 0.023 100.00 %3.043

Corrections - Air Gap: Level 0, Fasteners: Wall ties, Cross sectional area: 12.50 mm², Lambda: 17.000 W/m.K, per m²: 2.500

Layer5 Blockwork, denseMain construction 100 mm 1.590 100.00 %0.063

Layer6 Plaster, denseMain construction 18 mm 0.570 100.00 %0.032

Internal surface 0.130 Upper limit = 4.071 m²K/W Lower limit = 4.071 m²K/W Average = 4.071 m²K/WTotal resistance:

U-value (unrounded) = 0.2456 W/m²KUnheated space: None

U-value: 0.25 W/m²KTotal thickness: 358 mm

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 36: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

UVALUE CALCULATION

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

Building Elements:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Building Element Wall Type 1 - Dormer Timber Frame RenderedLayer FractionRλThicknessDescriptionExternal surface 0.040Layer1 Render

Main construction 18 mm 0.570 100.00 %0.032

Layer2 PlywoodMain construction 12 mm 0.130 100.00 %0.092

Layer3 Tuff-RTM Zero GA3000ZMain construction 50 mm 0.023 87.50 %2.174

Corrections - Air Gap: Level 0, Fasteners: None or plasticBridging - Timber 50 mm 0.130 12.50 %0.000

Layer4 Tuff-RTM Zero GA3000ZMain construction 50 mm 0.023 87.50 %0.000

Corrections - Air Gap: Level 0, Fasteners: None or plasticBridging - Timber 50 mm 0.130 12.50 %2.174

Layer5 Polythene,1000 gaugeMain construction 0 mm 0.000 100.00 %0.000

Layer6 Plasterboard, standardMain construction 13 mm 0.210 100.00 %0.060

Internal surface 0.130 Upper limit = 3.970 m²K/W Lower limit = 3.103 m²K/W Average = 3.536 m²K/WTotal resistance:

U-value (unrounded) = 0.2828 W/m²KUnheated space: None

U-value: 0.28 W/m²KTotal thickness: 143 mm

Building Element Wall Type 2 - Stud Walls to Roof SpacesLayer FractionRλThicknessDescriptionExternal surface 0.040Layer1 Celotex

Main construction 100 mm 0.023 87.50 %0.000Corrections - Air Gap: Level 0, Fasteners: None or plastic

Bridging - Timber 100 mm 0.130 12.50 %4.348Layer2 12.5mm Gyproc Wallboard

Main construction 13 mm 0.190 100.00 %0.066Corrections - Air Gap: Level 0, Fasteners: None or plastic

Internal surface 0.130 Upper limit = 3.172 m²K/W Lower limit = 2.985 m²K/W Average = 3.078 m²K/WTotal resistance:

U-value (unrounded) = 0.3248 W/m²KUnheated space: None

U-value: 0.32 W/m²KTotal thickness: 113 mm

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 37: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 1

CONDENSATION RISK ANALYSIS

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Wall Main - Dense Block with 70 Celotex

Environmental conditions:

External conditions: Temperature: 5 °C Relative Humidity: 95 %

Internal conditions: Relative Humidity: 65 %Temperature: 15 °C

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 38: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 2

Vapourresistance

GN.s/kg

Vapourresistivity

GN.s/kg.m

Thermalresistance

m2.K/W

Thermalconduct.

W/m.K

Width

mm

Layer Cumulativethermal

resistancem2.K/W

Cumulativevapour

resistanceGN.s/kg

Table of layers:

External surface 0.100 0.100 0.00- 0.000 0.000 0.0001. Tiling, clay 0.000 0.100 3.7515.0 1.000 250.0 3.752. Standard cavity 0.000 0.100 3.7525.0 0.000 0.000 0.0003. Sarking felt 0.000 0.100 4.751.0 0.190 1,000.0 1.004. Standard cavity 0.000 0.100 4.7550.0 0.000 0.000 0.0005. Celotex 4.348 4.448 4,342.05100.0 0.023 43,373.0 4,337.306. Celotex 2.174 6.622 6,510.7050.0 0.023 43,373.0 2,168.657. Plasterboard, standard 0.060 6.681 6,511.2612.5 0.210 45.0 0.56Internal surface 0.100 6.681 6,511.26- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Celotex 4.348 4.388 4,337.30100.0 0.023 43,373.0 4,337.302. 12.5mm Gyproc Wallboard 0.066 4.454 4,338.0512.5 0.190 60.0 0.75Internal surface 0.130 4.454 4,338.05- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.032 0.072 1.8018.0 0.570 100.0 1.802. Plywood 0.092 0.164 7.2012.0 0.130 450.0 5.403. Tuff-RTM Zero GA3000Z 2.174 2.338 2,175.8550.0 0.023 43,373.0 2,168.654. Tuff-RTM Zero GA3000Z 2.174 4.512 4,344.5050.0 0.023 43,373.0 2,168.655. Polythene,1000 gauge 0.000 4.512 4,844.50- 0.000 0.000 500.006. Plasterboard, standard 0.060 4.571 4,845.0612.5 0.210 45.0 0.56Internal surface 0.130 4.571 4,845.06- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Concrete, dense 0.050 0.090 20.00100.0 2.000 200.0 20.002. Expanded polystyrene 2.000 2.090 44.0080.0 0.040 300.0 24.003. Celotex 4.348 6.438 4,381.30100.0 0.023 43,373.0 4,337.304. Screed 0.183 6.621 4,381.3075.0 0.410 0.000 0.000Internal surface 0.170 6.621 4,381.30- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Mineral wool 3.750 3.790 1.50150.0 0.040 10.0 1.502. Mineral wool 3.750 7.540 3.00150.0 0.040 10.0 1.503. Plasterboard, standard 0.060 7.600 3.5612.5 0.210 45.0 0.56Internal surface 0.100 7.600 3.56- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.035 0.075 2.0020.0 0.570 100.0 2.002. Blockwork, dense 0.063 0.138 12.00100.0 1.590 100.0 10.003. High E Cavity 0.665 0.803 12.0050.0 0.000 0.000 0.0004. Tuff-RTM Zero GA3000Z 3.043 3.846 3,048.1170.0 0.023 43,373.0 3,036.115. Blockwork, dense 0.063 3.909 3,058.11100.0 1.590 100.0 10.006. Plaster, dense 0.032 3.941 3,059.1918.0 0.570 60.0 1.08Internal surface 0.130 3.941 3,059.19- 0.000 0.000 0.000

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 39: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 3

Satur.vapour

pressurePa

Vapourpressure

Pa

Interfacetemp.

°C

Interface - between layers

Vapour pressure table:

Cond.rate

60 daysg/m2.h

Cond.risk

Y/N

Cond.rate

g/m2.h

Dewpoint

°C

External surface 5.00 828.3 871.9 0.00 No0.004.271. External surface / Render 5.10 828.3 877.9 0.00 No0.004.272. Render / Blockwork, dense 5.18 828.5 883.2 0.00 No0.004.273. Blockwork, dense / High E Cavity 5.34 829.4 892.7 0.00 No0.004.294. High E Cavity / Tuff-RTM Zero GA3000Z 6.97 829.4 999.4 0.00 No0.004.295. Tuff-RTM Zero GA3000Z / Blockwork, dense 14.45 1 106.9 1 644.8 0.00 No0.008.476. Blockwork, dense / Plaster, dense 14.60 1 107.8 1 661.3 0.00 No0.008.487. Plaster, dense / Internal surface 14.68 1 107.9 1 669.7 0.00 No0.008.48Internal surface 15.00 1 107.9 1 669.7 0.00 No0.008.48

800

1000

1200

1400

1600

1800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

VPressure SatVPressure

Interface

Vapo

ur p

ress

ure

(Pa)

4

6

8

10

12

14

16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

Temperature DewPoint

Interface

Tem

pera

ture

(Pa)

Interface temperature / Dew point graphical representation:

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 40: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 4

CONDENSATION RISK ANALYSIS

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Roof Plane 1 - Pitched roof - insulated ceiling

Environmental conditions:

External conditions: Temperature: 5 °C Relative Humidity: 95 %

Internal conditions: Relative Humidity: 65 %Temperature: 15 °C

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 41: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 5

Vapourresistance

GN.s/kg

Vapourresistivity

GN.s/kg.m

Thermalresistance

m2.K/W

Thermalconduct.

W/m.K

Width

mm

Layer Cumulativethermal

resistancem2.K/W

Cumulativevapour

resistanceGN.s/kg

Table of layers:

External surface 0.100 0.100 0.00- 0.000 0.000 0.0001. Tiling, clay 0.000 0.100 3.7515.0 1.000 250.0 3.752. Standard cavity 0.000 0.100 3.7525.0 0.000 0.000 0.0003. Sarking felt 0.000 0.100 4.751.0 0.190 1,000.0 1.004. Standard cavity 0.000 0.100 4.7550.0 0.000 0.000 0.0005. Celotex 4.348 4.448 4,342.05100.0 0.023 43,373.0 4,337.306. Celotex 2.174 6.622 6,510.7050.0 0.023 43,373.0 2,168.657. Plasterboard, standard 0.060 6.681 6,511.2612.5 0.210 45.0 0.56Internal surface 0.100 6.681 6,511.26- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Celotex 4.348 4.388 4,337.30100.0 0.023 43,373.0 4,337.302. 12.5mm Gyproc Wallboard 0.066 4.454 4,338.0512.5 0.190 60.0 0.75Internal surface 0.130 4.454 4,338.05- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.032 0.072 1.8018.0 0.570 100.0 1.802. Plywood 0.092 0.164 7.2012.0 0.130 450.0 5.403. Tuff-RTM Zero GA3000Z 2.174 2.338 2,175.8550.0 0.023 43,373.0 2,168.654. Tuff-RTM Zero GA3000Z 2.174 4.512 4,344.5050.0 0.023 43,373.0 2,168.655. Polythene,1000 gauge 0.000 4.512 4,844.50- 0.000 0.000 500.006. Plasterboard, standard 0.060 4.571 4,845.0612.5 0.210 45.0 0.56Internal surface 0.130 4.571 4,845.06- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Concrete, dense 0.050 0.090 20.00100.0 2.000 200.0 20.002. Expanded polystyrene 2.000 2.090 44.0080.0 0.040 300.0 24.003. Celotex 4.348 6.438 4,381.30100.0 0.023 43,373.0 4,337.304. Screed 0.183 6.621 4,381.3075.0 0.410 0.000 0.000Internal surface 0.170 6.621 4,381.30- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Mineral wool 3.750 3.790 1.50150.0 0.040 10.0 1.502. Mineral wool 3.750 7.540 3.00150.0 0.040 10.0 1.503. Plasterboard, standard 0.060 7.600 3.5612.5 0.210 45.0 0.56Internal surface 0.100 7.600 3.56- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.035 0.075 2.0020.0 0.570 100.0 2.002. Blockwork, dense 0.063 0.138 12.00100.0 1.590 100.0 10.003. High E Cavity 0.665 0.803 12.0050.0 0.000 0.000 0.0004. Tuff-RTM Zero GA3000Z 3.043 3.846 3,048.1170.0 0.023 43,373.0 3,036.115. Blockwork, dense 0.063 3.909 3,058.11100.0 1.590 100.0 10.006. Plaster, dense 0.032 3.941 3,059.1918.0 0.570 60.0 1.08Internal surface 0.130 3.941 3,059.19- 0.000 0.000 0.000

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 42: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 6

Satur.vapour

pressurePa

Vapourpressure

Pa

Interfacetemp.

°C

Interface - between layers

Vapour pressure table:

Cond.rate

60 daysg/m2.h

Cond.risk

Y/N

Cond.rate

g/m2.h

Dewpoint

°C

External surface 5.00 828.3 871.9 0.00 No0.004.271. External surface / Mineral wool 5.05 828.3 875.0 0.00 No0.004.272. Mineral wool / Mineral wool 9.92 946.0 1 220.9 0.00 No0.006.173. Mineral wool / Plasterboard, standard 14.79 1 063.7 1 681.8 0.00 No0.007.884. Plasterboard, standard / Internal surface 14.87 1 107.9 1 690.2 0.00 No0.008.48Internal surface 15.00 1 107.9 1 690.2 0.00 No0.008.48

800

1000

1200

1400

1600

1800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

VPressure SatVPressure

Interface

Vapo

ur p

ress

ure

(Pa)

4

6

8

10

12

14

16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

Temperature DewPoint

Interface

Tem

pera

ture

(Pa)

Interface temperature / Dew point graphical representation:

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 43: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 7

CONDENSATION RISK ANALYSIS

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Floor 1 - Slab on the ground floor

Environmental conditions:

External conditions: Temperature: 5 °C Relative Humidity: 95 %

Internal conditions: Relative Humidity: 65 %Temperature: 15 °C

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 44: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 8

Vapourresistance

GN.s/kg

Vapourresistivity

GN.s/kg.m

Thermalresistance

m2.K/W

Thermalconduct.

W/m.K

Width

mm

Layer Cumulativethermal

resistancem2.K/W

Cumulativevapour

resistanceGN.s/kg

Table of layers:

External surface 0.100 0.100 0.00- 0.000 0.000 0.0001. Tiling, clay 0.000 0.100 3.7515.0 1.000 250.0 3.752. Standard cavity 0.000 0.100 3.7525.0 0.000 0.000 0.0003. Sarking felt 0.000 0.100 4.751.0 0.190 1,000.0 1.004. Standard cavity 0.000 0.100 4.7550.0 0.000 0.000 0.0005. Celotex 4.348 4.448 4,342.05100.0 0.023 43,373.0 4,337.306. Celotex 2.174 6.622 6,510.7050.0 0.023 43,373.0 2,168.657. Plasterboard, standard 0.060 6.681 6,511.2612.5 0.210 45.0 0.56Internal surface 0.100 6.681 6,511.26- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Celotex 4.348 4.388 4,337.30100.0 0.023 43,373.0 4,337.302. 12.5mm Gyproc Wallboard 0.066 4.454 4,338.0512.5 0.190 60.0 0.75Internal surface 0.130 4.454 4,338.05- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.032 0.072 1.8018.0 0.570 100.0 1.802. Plywood 0.092 0.164 7.2012.0 0.130 450.0 5.403. Tuff-RTM Zero GA3000Z 2.174 2.338 2,175.8550.0 0.023 43,373.0 2,168.654. Tuff-RTM Zero GA3000Z 2.174 4.512 4,344.5050.0 0.023 43,373.0 2,168.655. Polythene,1000 gauge 0.000 4.512 4,844.50- 0.000 0.000 500.006. Plasterboard, standard 0.060 4.571 4,845.0612.5 0.210 45.0 0.56Internal surface 0.130 4.571 4,845.06- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Concrete, dense 0.050 0.090 20.00100.0 2.000 200.0 20.002. Expanded polystyrene 2.000 2.090 44.0080.0 0.040 300.0 24.003. Celotex 4.348 6.438 4,381.30100.0 0.023 43,373.0 4,337.304. Screed 0.183 6.621 4,381.3075.0 0.410 0.000 0.000Internal surface 0.170 6.621 4,381.30- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Mineral wool 3.750 3.790 1.50150.0 0.040 10.0 1.502. Mineral wool 3.750 7.540 3.00150.0 0.040 10.0 1.503. Plasterboard, standard 0.060 7.600 3.5612.5 0.210 45.0 0.56Internal surface 0.100 7.600 3.56- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.035 0.075 2.0020.0 0.570 100.0 2.002. Blockwork, dense 0.063 0.138 12.00100.0 1.590 100.0 10.003. High E Cavity 0.665 0.803 12.0050.0 0.000 0.000 0.0004. Tuff-RTM Zero GA3000Z 3.043 3.846 3,048.1170.0 0.023 43,373.0 3,036.115. Blockwork, dense 0.063 3.909 3,058.11100.0 1.590 100.0 10.006. Plaster, dense 0.032 3.941 3,059.1918.0 0.570 60.0 1.08Internal surface 0.130 3.941 3,059.19- 0.000 0.000 0.000

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 45: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 9

Satur.vapour

pressurePa

Vapourpressure

Pa

Interfacetemp.

°C

Interface - between layers

Vapour pressure table:

Cond.rate

60 daysg/m2.h

Cond.risk

Y/N

Cond.rate

g/m2.h

Dewpoint

°C

External surface 5.00 828.3 871.9 0.00 No0.004.271. External surface / Concrete, dense 5.06 828.3 875.5 0.00 No0.004.272. Concrete, dense / Expanded polystyrene 5.13 829.5 880.0 0.00 No0.004.293. Expanded polystyrene / Celotex 8.08 831.1 1 077.9 0.00 No0.004.324. Celotex / Screed 14.48 1 107.9 1 648.2 0.00 No0.008.485. Screed / Internal surface 14.75 1 107.9 1 677.1 0.00 No0.008.48Internal surface 15.00 1 107.9 1 677.1 0.00 No0.008.48

800

1000

1200

1400

1600

1800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

VPressure SatVPressure

Interface

Vapo

ur p

ress

ure

(Pa)

4

6

8

10

12

14

16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

Temperature DewPoint

Interface

Tem

pera

ture

(Pa)

Interface temperature / Dew point graphical representation:

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 46: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 10

CONDENSATION RISK ANALYSIS

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Wall Type 1 - Dormer Timber Frame Rendered

Environmental conditions:

External conditions: Temperature: 5 °C Relative Humidity: 95 %

Internal conditions: Relative Humidity: 65 %Temperature: 15 °C

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 47: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 11

Vapourresistance

GN.s/kg

Vapourresistivity

GN.s/kg.m

Thermalresistance

m2.K/W

Thermalconduct.

W/m.K

Width

mm

Layer Cumulativethermal

resistancem2.K/W

Cumulativevapour

resistanceGN.s/kg

Table of layers:

External surface 0.100 0.100 0.00- 0.000 0.000 0.0001. Tiling, clay 0.000 0.100 3.7515.0 1.000 250.0 3.752. Standard cavity 0.000 0.100 3.7525.0 0.000 0.000 0.0003. Sarking felt 0.000 0.100 4.751.0 0.190 1,000.0 1.004. Standard cavity 0.000 0.100 4.7550.0 0.000 0.000 0.0005. Celotex 4.348 4.448 4,342.05100.0 0.023 43,373.0 4,337.306. Celotex 2.174 6.622 6,510.7050.0 0.023 43,373.0 2,168.657. Plasterboard, standard 0.060 6.681 6,511.2612.5 0.210 45.0 0.56Internal surface 0.100 6.681 6,511.26- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Celotex 4.348 4.388 4,337.30100.0 0.023 43,373.0 4,337.302. 12.5mm Gyproc Wallboard 0.066 4.454 4,338.0512.5 0.190 60.0 0.75Internal surface 0.130 4.454 4,338.05- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.032 0.072 1.8018.0 0.570 100.0 1.802. Plywood 0.092 0.164 7.2012.0 0.130 450.0 5.403. Tuff-RTM Zero GA3000Z 2.174 2.338 2,175.8550.0 0.023 43,373.0 2,168.654. Tuff-RTM Zero GA3000Z 2.174 4.512 4,344.5050.0 0.023 43,373.0 2,168.655. Polythene,1000 gauge 0.000 4.512 4,844.50- 0.000 0.000 500.006. Plasterboard, standard 0.060 4.571 4,845.0612.5 0.210 45.0 0.56Internal surface 0.130 4.571 4,845.06- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Concrete, dense 0.050 0.090 20.00100.0 2.000 200.0 20.002. Expanded polystyrene 2.000 2.090 44.0080.0 0.040 300.0 24.003. Celotex 4.348 6.438 4,381.30100.0 0.023 43,373.0 4,337.304. Screed 0.183 6.621 4,381.3075.0 0.410 0.000 0.000Internal surface 0.170 6.621 4,381.30- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Mineral wool 3.750 3.790 1.50150.0 0.040 10.0 1.502. Mineral wool 3.750 7.540 3.00150.0 0.040 10.0 1.503. Plasterboard, standard 0.060 7.600 3.5612.5 0.210 45.0 0.56Internal surface 0.100 7.600 3.56- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.035 0.075 2.0020.0 0.570 100.0 2.002. Blockwork, dense 0.063 0.138 12.00100.0 1.590 100.0 10.003. High E Cavity 0.665 0.803 12.0050.0 0.000 0.000 0.0004. Tuff-RTM Zero GA3000Z 3.043 3.846 3,048.1170.0 0.023 43,373.0 3,036.115. Blockwork, dense 0.063 3.909 3,058.11100.0 1.590 100.0 10.006. Plaster, dense 0.032 3.941 3,059.1918.0 0.570 60.0 1.08Internal surface 0.130 3.941 3,059.19- 0.000 0.000 0.000

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 48: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 12

Satur.vapour

pressurePa

Vapourpressure

Pa

Interfacetemp.

°C

Interface - between layers

Vapour pressure table:

Cond.rate

60 daysg/m2.h

Cond.risk

Y/N

Cond.rate

g/m2.h

Dewpoint

°C

External surface 5.00 828.3 871.9 0.00 No0.004.271. External surface / Render 5.09 828.3 877.1 0.00 No0.004.272. Render / Plywood 5.15 828.4 881.2 0.00 No0.004.273. Plywood / Tuff-RTM Zero GA3000Z 5.35 828.7 893.3 0.00 No0.004.274. Tuff-RTM Zero GA3000Z / Tuff-RTM Zero GA3000Z 9.97 953.8 1 225.1 0.00 No0.006.295. Tuff-RTM Zero GA3000Z / Polythene,1000 gauge 14.60 1 079.0 1 660.7 0.00 No0.008.096. Polythene,1000 gauge / Plasterboard, standard 14.60 1 107.8 1 660.7 0.00 No0.008.487. Plasterboard, standard / Internal surface 14.72 1 107.9 1 674.3 0.00 No0.008.48Internal surface 15.00 1 107.9 1 674.3 0.00 No0.008.48

800

1000

1200

1400

1600

1800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

VPressure SatVPressure

Interface

Vapo

ur p

ress

ure

(Pa)

4

6

8

10

12

14

16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

Temperature DewPoint

Interface

Tem

pera

ture

(Pa)

Interface temperature / Dew point graphical representation:

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 49: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 13

CONDENSATION RISK ANALYSIS

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Wall Type 2 - Stud Walls to Roof Spaces

Environmental conditions:

External conditions: Temperature: 5 °C Relative Humidity: 95 %

Internal conditions: Relative Humidity: 65 %Temperature: 15 °C

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 50: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 14

Vapourresistance

GN.s/kg

Vapourresistivity

GN.s/kg.m

Thermalresistance

m2.K/W

Thermalconduct.

W/m.K

Width

mm

Layer Cumulativethermal

resistancem2.K/W

Cumulativevapour

resistanceGN.s/kg

Table of layers:

External surface 0.100 0.100 0.00- 0.000 0.000 0.0001. Tiling, clay 0.000 0.100 3.7515.0 1.000 250.0 3.752. Standard cavity 0.000 0.100 3.7525.0 0.000 0.000 0.0003. Sarking felt 0.000 0.100 4.751.0 0.190 1,000.0 1.004. Standard cavity 0.000 0.100 4.7550.0 0.000 0.000 0.0005. Celotex 4.348 4.448 4,342.05100.0 0.023 43,373.0 4,337.306. Celotex 2.174 6.622 6,510.7050.0 0.023 43,373.0 2,168.657. Plasterboard, standard 0.060 6.681 6,511.2612.5 0.210 45.0 0.56Internal surface 0.100 6.681 6,511.26- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Celotex 4.348 4.388 4,337.30100.0 0.023 43,373.0 4,337.302. 12.5mm Gyproc Wallboard 0.066 4.454 4,338.0512.5 0.190 60.0 0.75Internal surface 0.130 4.454 4,338.05- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.032 0.072 1.8018.0 0.570 100.0 1.802. Plywood 0.092 0.164 7.2012.0 0.130 450.0 5.403. Tuff-RTM Zero GA3000Z 2.174 2.338 2,175.8550.0 0.023 43,373.0 2,168.654. Tuff-RTM Zero GA3000Z 2.174 4.512 4,344.5050.0 0.023 43,373.0 2,168.655. Polythene,1000 gauge 0.000 4.512 4,844.50- 0.000 0.000 500.006. Plasterboard, standard 0.060 4.571 4,845.0612.5 0.210 45.0 0.56Internal surface 0.130 4.571 4,845.06- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Concrete, dense 0.050 0.090 20.00100.0 2.000 200.0 20.002. Expanded polystyrene 2.000 2.090 44.0080.0 0.040 300.0 24.003. Celotex 4.348 6.438 4,381.30100.0 0.023 43,373.0 4,337.304. Screed 0.183 6.621 4,381.3075.0 0.410 0.000 0.000Internal surface 0.170 6.621 4,381.30- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Mineral wool 3.750 3.790 1.50150.0 0.040 10.0 1.502. Mineral wool 3.750 7.540 3.00150.0 0.040 10.0 1.503. Plasterboard, standard 0.060 7.600 3.5612.5 0.210 45.0 0.56Internal surface 0.100 7.600 3.56- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.035 0.075 2.0020.0 0.570 100.0 2.002. Blockwork, dense 0.063 0.138 12.00100.0 1.590 100.0 10.003. High E Cavity 0.665 0.803 12.0050.0 0.000 0.000 0.0004. Tuff-RTM Zero GA3000Z 3.043 3.846 3,048.1170.0 0.023 43,373.0 3,036.115. Blockwork, dense 0.063 3.909 3,058.11100.0 1.590 100.0 10.006. Plaster, dense 0.032 3.941 3,059.1918.0 0.570 60.0 1.08Internal surface 0.130 3.941 3,059.19- 0.000 0.000 0.000

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 51: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 15

Satur.vapour

pressurePa

Vapourpressure

Pa

Interfacetemp.

°C

Interface - between layers

Vapour pressure table:

Cond.rate

60 daysg/m2.h

Cond.risk

Y/N

Cond.rate

g/m2.h

Dewpoint

°C

External surface 5.00 828.3 871.9 0.00 No0.004.271. External surface / Celotex 5.09 828.3 877.2 0.00 No0.004.272. Celotex / 12.5mm Gyproc Wallboard 14.57 1 107.8 1 658.1 0.00 No0.008.483. 12.5mm Gyproc Wallboard / Internal surface 14.72 1 107.9 1 673.5 0.00 No0.008.48Internal surface 15.00 1 107.9 1 673.5 0.00 No0.008.48

800

1000

1200

1400

1600

1800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

VPressure SatVPressure

Interface

Vapo

ur p

ress

ure

(Pa)

4

6

8

10

12

14

16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

Temperature DewPoint

Interface

Tem

pera

ture

(Pa)

Interface temperature / Dew point graphical representation:

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 52: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 16

CONDENSATION RISK ANALYSIS

DER: 16.68TER: 19.15

Prop Type Ref:Issued on: 2.March.2016

East Castle, Tiers Cross, HAVERFORDWEST, Dyfed, SA62 3EG

A998-0001-09-56

Property:

Users Ref:

0.00ZC:1Ene1:SAP Energy Cost: CO2 Emissions: 4.80 t/year

Energy used: 83 kWh/m2/yearSAP Rating: £495.94EI Rating:

83 B81 B

SAP version: 9.81 Regs Region: England and Wales (Part L1A 2006), Calculation Type: New BuildSoftware Version: EES SAP 2005.018.03, October 2009 (Design System), BRE SAP Worksheet 9.81

I000-0008, Ian MacraeSurveyor:Address:Client:

Calculation method: BS EN ISO 6946, BS EN ISO 13370, BS 5250

Roof Slope 1 - Pitched roof - insulated slope, sloping ceiling

Environmental conditions:

External conditions: Temperature: 5 °C Relative Humidity: 95 %

Internal conditions: Relative Humidity: 65 %Temperature: 15 °C

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 53: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 17

Vapourresistance

GN.s/kg

Vapourresistivity

GN.s/kg.m

Thermalresistance

m2.K/W

Thermalconduct.

W/m.K

Width

mm

Layer Cumulativethermal

resistancem2.K/W

Cumulativevapour

resistanceGN.s/kg

Table of layers:

External surface 0.100 0.100 0.00- 0.000 0.000 0.0001. Tiling, clay 0.000 0.100 3.7515.0 1.000 250.0 3.752. Standard cavity 0.000 0.100 3.7525.0 0.000 0.000 0.0003. Sarking felt 0.000 0.100 4.751.0 0.190 1,000.0 1.004. Standard cavity 0.000 0.100 4.7550.0 0.000 0.000 0.0005. Celotex 4.348 4.448 4,342.05100.0 0.023 43,373.0 4,337.306. Celotex 2.174 6.622 6,510.7050.0 0.023 43,373.0 2,168.657. Plasterboard, standard 0.060 6.681 6,511.2612.5 0.210 45.0 0.56Internal surface 0.100 6.681 6,511.26- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Celotex 4.348 4.388 4,337.30100.0 0.023 43,373.0 4,337.302. 12.5mm Gyproc Wallboard 0.066 4.454 4,338.0512.5 0.190 60.0 0.75Internal surface 0.130 4.454 4,338.05- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.032 0.072 1.8018.0 0.570 100.0 1.802. Plywood 0.092 0.164 7.2012.0 0.130 450.0 5.403. Tuff-RTM Zero GA3000Z 2.174 2.338 2,175.8550.0 0.023 43,373.0 2,168.654. Tuff-RTM Zero GA3000Z 2.174 4.512 4,344.5050.0 0.023 43,373.0 2,168.655. Polythene,1000 gauge 0.000 4.512 4,844.50- 0.000 0.000 500.006. Plasterboard, standard 0.060 4.571 4,845.0612.5 0.210 45.0 0.56Internal surface 0.130 4.571 4,845.06- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Concrete, dense 0.050 0.090 20.00100.0 2.000 200.0 20.002. Expanded polystyrene 2.000 2.090 44.0080.0 0.040 300.0 24.003. Celotex 4.348 6.438 4,381.30100.0 0.023 43,373.0 4,337.304. Screed 0.183 6.621 4,381.3075.0 0.410 0.000 0.000Internal surface 0.170 6.621 4,381.30- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Mineral wool 3.750 3.790 1.50150.0 0.040 10.0 1.502. Mineral wool 3.750 7.540 3.00150.0 0.040 10.0 1.503. Plasterboard, standard 0.060 7.600 3.5612.5 0.210 45.0 0.56Internal surface 0.100 7.600 3.56- 0.000 0.000 0.000External surface 0.040 0.040 0.00- 0.000 0.000 0.0001. Render 0.035 0.075 2.0020.0 0.570 100.0 2.002. Blockwork, dense 0.063 0.138 12.00100.0 1.590 100.0 10.003. High E Cavity 0.665 0.803 12.0050.0 0.000 0.000 0.0004. Tuff-RTM Zero GA3000Z 3.043 3.846 3,048.1170.0 0.023 43,373.0 3,036.115. Blockwork, dense 0.063 3.909 3,058.11100.0 1.590 100.0 10.006. Plaster, dense 0.032 3.941 3,059.1918.0 0.570 60.0 1.08Internal surface 0.130 3.941 3,059.19- 0.000 0.000 0.000

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB

Page 54: pbproduction.blob.core.windows.net · 8.0 Living Area 60.96, fraction: 0.20 7.0 Internal Floor Area 116.23 m2, 99.72 m2, 85.39 m2 6.0 Internal Walls Perimeter 48.30 m, 43.47 m, 41.66

Page: 18

Satur.vapour

pressurePa

Vapourpressure

Pa

Interfacetemp.

°C

Interface - between layers

Vapour pressure table:

Cond.rate

60 daysg/m2.h

Cond.risk

Y/N

Cond.rate

g/m2.h

Dewpoint

°C

External surface 5.00 828.3 871.9 0.00 No0.004.271. External surface / Tiling, clay 5.15 828.3 880.9 0.00 No0.004.272. Tiling, clay / Standard cavity 5.15 828.4 880.9 0.00 No0.004.273. Standard cavity / Sarking felt 5.15 828.4 880.9 0.00 No0.004.274. Sarking felt / Standard cavity 5.15 828.5 880.9 0.00 No0.004.275. Standard cavity / Celotex 5.15 828.5 880.9 0.00 No0.004.276. Celotex / Celotex 11.56 1 014.7 1 361.6 0.00 No0.007.197. Celotex / Plasterboard, standard 14.76 1 107.8 1 678.8 0.00 No0.008.488. Plasterboard, standard / Internal surface 14.85 1 107.9 1 688.3 0.00 No0.008.48Internal surface 15.00 1 107.9 1 688.3 0.00 No0.008.48

800

1000

1200

1400

1600

1800

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

VPressure SatVPressure

Interface

Vapo

ur p

ress

ure

(Pa)

4

6

8

10

12

14

16

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45

Temperature DewPoint

Interface

Tem

pera

ture

(Pa)

Interface temperature / Dew point graphical representation:

Elmhurst Energy Systems Limited Registered Office Unit 16, St Johns Business Park, Lutterworth, Leicestershire LE17 4HB