8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

10
Daikin 8Zone MultiSplit System Activities 1

Transcript of 8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

Page 1: 8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

Daikin 8‐Zone Multi‐Split System

Activities

1

Page 2: 8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

1. 8 Zone Multi Split Control Wire Specification:

2.  Control Terminal Designations on 8 Zone Multi Split Condensers: 

3.  Control Terminal Designations on BPMXS048A2U or BPMX049A3U Branch Provider Boxes:

4.  Control Terminal Designations on Multi Split Fan Coils:

Indicate the Control Terminal Designations 

Indicate the Control Terminal Designations 

Indicate the Control Terminal Designations 

Indicate the 8 Zone Multi Split Control Wire Specification

Exercise #1Fill in your answers below.

2

Page 3: 8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

5. 8 Zone Multi Split REFNET positioning:

6.  8 Zone Multi Split Branch Provider Box positioning:

7. 8 Zone Multi Split Branch Provider Box positioning:

8.  Piping Rules:

Can 8 Zone branch provider boxes be installed in attics?

What is the maximum total length of piping for an 8 Zone Multi Split system?

Do branch provider boxes need to be installed level or can they be tilted?

Daikin REFNETS can be installed at what positions?

Exercise #1 ContinuedFill in your answers below.

3

Page 4: 8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

Wiring Exercise ExampleDraw in each circuit using a different color pencil or pen from component terminal to component terminal.

## ## ## ## ## ##

## ## ## ## ## ##

RMXS48LVJU FTXS15LVJU                          

## ## ## ## ## ##

4

Page 5: 8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

Zone A

RMXS48LVJU FTXS15LVJU                          

F1 F2 IN

F1 F2 OUT       

FFQ15LVJU                          

Zone B

F2F1

12

34

12

34

L2L1

1 2 3 4

12

34

1 2 3 4

Zone C

FDXS12LVJU                         

1 2 3 4

Exercise #2 RMXS48LVJU ‐ 3 zonesDraw in each circuit using a different color pencil or pen from component terminal to component terminal.

5

Page 6: 8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

FTXS__LVJU                           FFQ__LVJU                           FDXS__LVJU                          

Daikin ENVi ARC452Wireless

BRC7E830/BRC4C82

Wireless  Kit

BRC944Wired BRC1E72

Navigation

ARC447Quaternity

Exercise #3 Indoor Units andRemote ControllersDraw a line from the indoor unit to the remote controller(s) that can be used with it.

6

Page 7: 8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

1. 8 Zone Multi Split Control Wire Specification:

2.  Control Terminal Designations on 8 Zone Multi Split Condensers: 

3.  Control Terminal Designations on BPMXS048A2U or BPMX049A3U Branch Provider Boxes:

4.  Control Terminal Designations on Multi Split Fan Coils:

Indicate the Control Terminal Designations 

Indicate the Control Terminal Designations 

Indicate the Control Terminal Designations 

Indicate the 8 Zone Multi Split Control Wire Specification

Exercise #1 Answer KeyFill in your answers below.

AWG 18-16 from OD to BP, From BP to ID is AWG 14-16

F1 F2 In

F1 F2

1, 2, 3, 4 & ground

7

Page 8: 8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

5. 8 Zone Multi Split REFNET positioning:

6.  8 Zone Multi Split Branch Provider Box positioning:

7. 8 Zone Multi Split Branch Provider Box positioning:

8.  Piping Rules:

Can 8 Zone branch provider boxes be installed in attics?

What is the maximum total length of piping for an 8 Zone Multi Split system?

Do branch provider boxes need to be installed level or can they be tilted?

Daikin REFNETS can be installed at what positions?

Exercise #1 Continued Answer KeyFill in your answers below.

Straight up, straight down, level (+/- 30°)

Attic installation is allowed, however, branch provider boxes cannot be installed in hot or humid locations where the temperature reaches 140°

Branch provider boxes must be installed level

440 ft

8

Page 9: 8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

Zone A

RMXS48LVJU FTXS15LVJU                          

F1 F2 IN

F1 F2 OUT       

FFQ15LVJU                          

Zone B

F2F1

12

34

12

34

L2L1

1 2 3 4

12

34

1 2 3 4

Zone C

FDXS12LVJU                         

1 2 3 4

Exercise #2 RMXS48LVJU ‐ 3 zonesAnswer Key

9

Page 10: 8-Zone Multi-Split System Key Points Install Module Participant Activity -Participant Version

Daikin ENVi ARC452Wireless

BRC7E830/BRC4C82

Wireless  Kit

BRC944Wired BRC1E72

Navigation

ARC447Quaternity

Exercise #3 Indoor Units andRemote Controllers Answer Key.

FTXS__LVJU                           FFQ__LVJU                           FDXS__LVJU                          

10