8 Series P5 Processors - Lutron...

4
http://resi.lutron.com Technical Support: [email protected] INTRODUCTION SPECIFICATION & DESIGN FRONT ROOM BACK ROOM APPENDIX Model Numbers Input Voltage Regulatory Approvals Environment Cooling Method Heat Generated Fully Loaded Line-Voltage Connections Low-Voltage Wire Type Low-Voltage Wiring Configuration Low-Voltage Connections Addressing Diagnostics ESD Protection Surge Protection Miswire Protection Power-Failure Memory Internal Timeclock Mounting Mounting Hole Locations Shipping Weight (all model numbers) H8P5-120: Wired Processor only H8P5-D48-120: Wired Processor with one integral Dimmer Interface (D48) H8P5-H48-120: Wired Processor with one integral Dimmer Interface (H48) H8P5-MI-120: Wired Processor with one integral Module Interface H8P5-MI-D48-120: Wired Processor with one integral Module Interface and one integral Dimmer Interface (D48) H8P5-MI-H48-120: Wired Processor with one integral Module Interface and one integral Dimmer Interface (H48) 120 V 50 / 60 Hz UL, CSA, NOM Ambient operating temperature: 0 °C to 40 °C, 32 °F to 104 °F Ambient operating humidity: 0-90% humidity, non-condensing Indoor use only Passive cooling 18 BTUs per hr Mates with Lutron-provided 2-pin pigtail on DIN-rail terminal block Power switch provided on top left of processor Terminal blocks should be tightened to 35-50 in-lbs (040-057 Nm) Two pair — one pair #18 AWG (10 mm 2 ), one pair #18-22 AWG (10-05 mm 2 ) twisted shield- ed — NEC ® Class 2 (IEC PELV) cable All processors in a multi-processor system must have the inter-processor communication links connected in a daisy-chain configuration 4-pin removable terminal block Each of the four terminals will accept up to two #18 AWG (10 mm 2 ) wires Up to two standard female DB-9 serial RS-232 connections and one RJ-45 standard ethernet connection Via DIP Switch Counts as 1 of 16 processor addresses See Fig. 7, pg. 96. Power LED, Communication link power short circuit LED, Links 1-8 Tx and Rx LEDs Meets or exceeds the IEC 61000-4-2 standard Meets or exceeds ANSI/IEEE standard c6241 All terminal block inputs are over-voltage and miswire protected against wire reversals and shorts Lithium battery provides a minimum of ten years of data retention Accuracy ± 1 minute per year (specified as during data retention time) HWI-PNL-8: Processor mounts at bottom of panel See Fig. 10, pg. 98. HWI-LV32-120: Processor mounts at top of enclosure See Fig. 9, pg. 98. See Fig. 6, pg. 96. 9 lbs (41 kg) 8 Series P5 Processors

Transcript of 8 Series P5 Processors - Lutron...

��http://resi.lutron.com Technical Support: [email protected]

IN

TRO

DU

CTION

SP

ECIFICATIO

N &

DESIG

N

FRO

NT R

OO

M

BA

CK R

OO

M

A

PP

END

IX

Model Numbers

Input Voltage

Regulatory Approvals

Environment

Cooling Method

Heat Generated Fully Loaded

Line-Voltage Connections

Low-Voltage Wire Type

Low-Voltage Wiring Configuration

Low-Voltage Connections

Addressing

Diagnostics

ESD Protection

Surge Protection

Miswire Protection

Power-Failure Memory

Internal Timeclock

Mounting

Mounting Hole Locations

Shipping Weight (all model numbers)

H8P5-120: Wired Processor only . H8P5-D48-120: Wired Processor with one integral Dimmer Interface (D48) . H8P5-H48-120: Wired Processor with one integral Dimmer Interface (H48) . H8P5-MI-120: Wired Processor with one integral Module Interface . H8P5-MI-D48-120: Wired Processor with one integral Module Interface and

one integral Dimmer Interface (D48) .H8P5-MI-H48-120: Wired Processor with one integral Module Interface and

one integral Dimmer Interface (H48) .

120 V 50 / 60 Hz

UL, CSA, NOM

Ambient operating temperature: 0 °C to 40 °C, 32 °F to 104 °F Ambient operating humidity: 0-90% humidity, non-condensing . Indoor use only .

Passive cooling .

18 BTUs per hr .

Mates with Lutron-provided 2-pin pigtail on DIN-rail terminal block . Power switch provided on top left of processor . Terminal blocks should be tightened to 3 .5-5 .0 in .-lbs . (0 .40-0 .57 N•m)

Two pair — one pair #18 AWG (1 .0 mm2), one pair #18-22 AWG (1 .0-0 .5 mm2) twisted shield-ed — NEC® Class 2 (IEC PELV) cable .

All processors in a multi-processor system must have the inter-processor communication links connected in a daisy-chain configuration .

4-pin removable terminal block . Each of the four terminals will accept up to two #18 AWG (1 .0 mm2) wires . Up to two standard female DB-9 serial RS-232 connections and one RJ-45 standard ethernet connection .

Via DIP Switch . Counts as 1 of 16 processor addresses . See Fig. 7, pg. 96.

Power LED, Communication link power short circuit LED, Links 1-8 Tx and Rx LEDs .

Meets or exceeds the IEC 61000-4-2 standard .

Meets or exceeds ANSI/IEEE standard c62 .41 .

All terminal block inputs are over-voltage and miswire protected against wire reversals and shorts .

Lithium battery provides a minimum of ten years of data retention .

Accuracy ± 1 minute per year (specified as during data retention time) .

HWI-PNL-8: Processor mounts at bottom of panel . See Fig. 10, pg. 98. HWI-LV32-120: Processor mounts at top of enclosure . See Fig. 9, pg. 98.

See Fig. 6, pg. 96.

9 lbs . (4 .1 kg)

8 Series P5 Processors

�� Technical Support • 24 Hours a Day/7 Days a Week • 1.800.523.9466

IN

TRO

DU

CTION

SP

ECIFICATIO

N &

DESIG

N

FRO

NT R

OO

M

BA

CK R

OO

M

A

PP

END

IX

8 Series P5 Processors (cont .)

Power Switch

Power Cord

Contact Closure Inputs

ConfigurationSwitch

Ethernet Port

Configuration DIP Switches

DIP Switch OFF ON

1 Normal Mode Boot Mode

2 User-Configured 9600 Baud Baud Rate

3-6 Address

Processor Board (all models)

Dimmer Hub (H8P5-H48-120, H8P5-D48-120,

H8P5-MI-H48-120(shown), and

H8P5-MI-D48-120 only)

Link Identification Label

Mounting Keyhole Mounting Keyhole Manual Override Switch

RPM harness connector (H8P5-MI-120, H8P5-MI-H48-120, and H8P5-MI-D48-120 only)

RPM harness (H8P5-MI-120, H8P5-MI-H48-120, and H8P5-MI-D48-120 only)

#16-24 AWG (1 .5 mm2- 0 .5 mm2) Wiring

Mounting Hole

hWI-MI-120

Figure � - 8 Series P5 Processor (h8P5-MI-h48-120 shown)

Figure � - Address DIP Switch Settings (configure switch S1)

Example: Setting Switch #6 ON.

OFF - Left

ON -Right

��http://resi.lutron.com Technical Support: [email protected]

IN

TRO

DU

CTION

SP

ECIFICATIO

N &

DESIG

N

FRO

NT R

OO

M

BA

CK R

OO

M

A

PP

END

IX

8 Series P5 Processors (cont .)

9 .95 in(252 .81 mm)

11 .96 in(303 .66 mm)

10 in(254 mm)

0 .93 in (23 .61 mm)

1 in (25 .4 mm)

11 .56 in (293 .6 mm)

5 .93 in (150 .61 mm)

Figure � – 8 Series P5 Processor Dimensions

25⁄16 in(59 .6 mm)

Front View Side View

�� Technical Support • 24 Hours a Day/7 Days a Week • 1.800.523.9466

IN

TRO

DU

CTION

SP

ECIFICATIO

N &

DESIG

N

FRO

NT R

OO

M

BA

CK R

OO

M

A

PP

END

IX

Figure � – Mounting location in an hWI-lv32-120

Control WiringEntry (Class 2)

Preferred PowerWiring Entry

HomeWorks Processor

HNN

H

NG

Control Wiring Entry (NEC Class 2; IEC PELV)

Preferred PowerWiring Entry

Alternate Power Wiring Entry

HomeWorks Processor

31⁄4 in (8 .25 cm)

Figure 10 – Mounting location in an hWI-PNl-8

8 Series P5 Processors (cont .)