5
3 265 CODES/STANDARDS USA 1B1 CODES/STANDARDS-CSA/CMVSS 1B1 265 4. POWER CORD BOX 3700 DROP (MAIN) FROM LOAD CENTER TO POWER CORD BOX RCP-2 (BLU) EXT COMPT 2 SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION. 1. AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATE FOR INSTALLATION. NOTES: WIRES ROUTED UNDER FLOOR. WIRE ROUTES THROUGH FLOOR IN THIS AREA. 900 LOOP TO RCP-EXTERIOR COMPARTMENT X-X FOR ELECTRICAL CALLOUTS SEE DWG NO. 121339-01-000 FOR ELECTRICAL TORQUE SPECIFICATIONS SEE DWG NO. 128783-01-000 2 2 12D ELECTRICAL SYSTEM 30 AMP 3 BLU, BRN CIRCUITS TO LEFT SIDE 2 (BLU) 5800 DROP THRU RCP-LAVATORY TO RCP-TV2 TO RCP-HALL (BRN) 500 DROP TO RCP-B UNDER DRESSER 3 UNSPECIFIED TOLERANCES: MATERIAL: C D 1 TWO-PLACE (X.XX) DSNR: DESCRIPTION: 8 2 B ALL DIMENSIONS ARE IN MILLIMETERS DFTR: 6 A 6 FIRST USED: A REV WHOLE DIM (X) D REF: 8 ITEM/PART NO: 4 WEIGHT: (LBS) SHEET: 7 B 2 4 REFER TO ES0018 FOR FASTENER TIGHTENING GUIDELINES ANGLE 5 5 1 3 COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC. ONE-PLACE (X.X) C 7 WIRING INSTL-BODY,110V 1 OF 5 000021890 / 31436201000 3 1.5 0.50 1 17 E32YE COOLING UPGRADE PACKAGE 073 AA VIEW AA VIEW AA 12D 073 FROM GENERATOR POWER CORD ATS PLATE-MOUNTING, LOAD CENTER 000024737 / 315088-01-CHT MAIN MAIN POWER CORD FROM GENERATOR 3 02-Jun-2017

Transcript of 8 7 6 5 4 3 1 2 - RVs, Motorhomes, Recreational Vehicles · sp-06 rcp-b (brn) under dresser ... rh...

3

265

CODES/STANDARDS USA1B1

CODES/STANDARDS-CSA/CMVSS

1B1 265

4.

POWER CORD BOX

3700 DROP (MAIN)FROM LOAD CENTERTO POWER CORD BOX

RCP-2 (BLU)EXT COMPT

2

SEE LOAD CENTER/ATS ASM FOR ADDITIONAL INFORMATION.

1.

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECUREDPER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 ORWIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX ORG56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

NOTES:

WIRES ROUTED UNDER FLOOR.

WIRE ROUTES THROUGH FLOOR IN THIS AREA.

900 LOOPTO RCP-EXTERIORCOMPARTMENT

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

2

2

12D ELECTRICAL SYSTEM 30 AMP

3

BLU, BRN CIRCUITSTO LEFT SIDE

2

(BLU) 5800 DROPTHRU RCP-LAVATORYTO RCP-TV2TO RCP-HALL(BRN) 500 DROPTO RCP-BUNDER DRESSER

3

UNSPECIFIED TOLERANCES: MATERIAL:

C

D

1

TWO-PLACE (X.XX)

DSNR:

DESCRIPTION:

8

2

B

ALL DIMENSIONS ARE IN MILLIMETERSDFTR:

6

A

6

FIRST USED:

A

REV

WHOLE DIM (X)

D

REF:

8

ITEM/PART NO:

4

WEIGHT: (LBS)

SHEET:

7

B

2

4

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

ANGLE

5

5

13

COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.

ONE-PLACE (X.X)

C

7

WIRING INSTL-BODY,110V

1 OF 5 000021890 / 31436201000

3

1.5

0.50

1

17 E32YE

COOLING UPGRADE PACKAGE073

AA

VIEW AAVIEW AA 12D073

FROMGENERATOR

POWER CORD

ATS

PLATE-MOUNTING, LOAD CENTER000024737 / 315088-01-CHT

MAINMAIN

POWER CORD

FROMGENERATOR

3

02-Jun-2017

NOTES:

RCP-2 (BLU)LAVATORY

265

WIRE ROUTED THRU FLOOR IN THIS AREA.

CODES/STANDARDS USA1B1

CODES/STANDARDS-CSA/CMVSSAT MINIMUM ALL WIRES TO BE SUPPORTED AND SECUREDPER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 ORWIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX ORG56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

2

WIRE ROUTED IN SIDEWALL.

1B1

3.

2

1

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

RCP-2 (BRN)DINETTE

SPACER-RCP133713-04-CHTSCREWG11-08-20D (4)

265

1

1

RCP-2 (BRN)TV1

WIRE PART OFWIRE ASM-CHASSIS

110V CONNECTORSDETAIL BA

SP-06

RCP-B (BRN)UNDER DRESSER

DETAIL BA1

CONNECTOR-WIRE,NM144283-02-000SCREWG39-06-24U (2)

TO DINETTE RCPFROM 110V

CONNECTIONSDETAIL CA

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000021890 / 31436201000 2 OF 5

1

RCP-2 (BLU)HALL

RCP-2 (BLU)TV2

RCP-2 (BRN)COUCH

1 SP-06 RCP-2 (BRN)COUNTERTOP

02-Jun-2017

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECUREDPER CODE REQUIREMENTS. USE CLAMP 10495 OR 10497 ORWIRE TIE 8343 OR 108046 AND SCREW G67-XX-XXX ORG56-XX-XXX AS APPROPRIATE FOR INSTALLATION.

CODES/STANDARDS-CSA/CMVSS

NOTES:

2

WIRE ROUTED IN ROOF.1B1 265

WIRE ROUTED IN SIDEWALL.

265

CODES/STANDARDS USA1B1

WIRE ROUTED THRU FLOOR IN THIS AREA.

3

4.

1

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

SP-061

SP-06 1

2

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000021890 / 31436201000 3 OF 5

ELECTRICAL SYSTEM 30 AMP12D

RCP-B (BRN)RH FRONT

RCP-2 (BRN)SDWL,RH,FRT

RCP-2 (BRN)A/V CABINET

RCP-1 (BLK)MICROWAVE

RCP-3 (YEL)REFRIGERATOR

RCP-B (BRN)SHOWER WALL 1

RCP-2 (BRN)BDRM REAR

RCP-B (BRN)UNDER GALLEY

COOLING UPGRADE PACKAGE073

EXT TV ENTERTAINMENT CENTER1DF

RCP-2 (BLU)EXT TV (REF) 1DF

RCP-2 (BLU)GALLEY 2

LOAD CENTER/ATS ASM000021891 / 314363-01-000000026587 / 315705-01-000

12D073

RCP-1 (YEL)CONVERTER

PANEL-RECEPTACLE188004-02-CHTSCREWG39-10-12U (2)

073

RCP-B (BLU)SIDEWALL

RCP-2 (BRN)BDRM FRT

110V CONNECTIONSDETAIL CB

110V CONNECTIONSDETAIL CA

RCP-B (GRN)SHOWER WALL 3

RCP-B (RED)SHOWER WALL 2

073

TO 110VCONNECTIONSDETAIL BA

DETAIL CA

FROM RCP-B(UNDER GALLEY)

THROW IN #1 WIRE PART OFWIRE ASM-CHASSIS

FROM RCP-B(UNDER GALLEY)

TO 110VCONNECTIONSDETAIL CB

WIRE PART OFWIRE ASM-CHASSIS

THROW IN #2

WIRE PART OFWIRE ASM-CHASSIS

THROW IN #3

TO RCP-BDRM FRONT

DETAIL CB

TO 110VCONNECTIONSDETAIL CA

BRACKET-110V CONNECTOR155223-05-CHTSCREWG39-10-12U(2)

RECEPTACLE-DOUBLE176149-01-CHT (YEL-2)(REFRIGERATOR)

144

79W

REFRIGERATOR-DOUBLE DOOR144

REFRIGERATOR-4 DOOR79W

RECEPTACLE ASM-GFI,US-15A000120175 / 322736-01-XXXRECEPTACLE ASM-GFI,CAN-15A000120176 / 322737-01-XXX(BLU) (GALLEY)

265

1B1

02-Jun-2017

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

2651B1

CODES/STANDARDS-CSA/CMVSS

1B1 CODES/STANDARDS USA

265

WIRE IN ROOF.

4

NOTES:

3 WIRE IN SIDEWALL.

SEE MANUFACTURER'S DIAGRAM.

1 ALL OUTLETS DOWN STREAM AND INCLUDINGTHIS OUTLET ARE GROUND FAULT INTERRUPTPROTECTED.

2

RCP-REFRIGERATOR

CONTROL CENTER

RCP-EXT COMPT

15

RCP-BSHOWERWALL 2

ROOFAIR

CONDITIONER

8 GRN CHASSISGROUND

20

RCP-MICROWAVE

15151530

FLEX CORD

210-2

POWERCORDASM

POWER CORDRECP BOX

JUNCTIONBOX

GENERATOR

14-214-2

10-2 14-2

12-2

THROW INWIRE #1

4

RCP-GFIGALLEY 1

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000021890 / 31436201000 4 OF 5

12D

ELECTRICAL SYSTEM 30 AMP12D

EXT TV ENTERTAINMENT CENTER1DF5 WIRES ARE PART OF WIRE ASM-CHASSIS.

14-2

1DF RCP-EXT TV

RCP-BSIDEWALL

3

RCP-GALLEY 2

RCP-LAVATORY

RCP-TV 2

RCP-HALL

RCP-BUNDERGALLEY

RCP-BSHOWERWALL 1

RCP-BRH FRONT

RCP-A/V

RCP-RT,FRT

SIDEWALL

2 3

THROW INWIRE #2

110V CONNECTION(UNDER GALLEY)

110V CONNECTION(IN SLIDEOUT)

5

RCP-COUCH

RCP-DINETTE

3

110V CONNECTION(UNDER BED)

110V CONNECTION(UNDER GALLEY)

RCP-BDRMFRONT

RCP-BDRMREAR

5 FLEX CORD THROW INWIRE #3

RCP-BUNDER

DRESSER

3

RCP-TV1

3

RCP-COUNTERTOP

02-Jun-2017

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

2651B1

CODES/STANDARDS-CSA/CMVSS

1B1 CODES/STANDARDS USA

265

WIRE IN ROOF.

4

NOTES:

3 WIRE IN SIDEWALL.

SEE MANUFACTURER'S DIAGRAM.

1 ALL OUTLETS DOWN STREAM AND INCLUDINGTHIS OUTLET ARE GROUND FAULT INTERRUPTPROTECTED.

2

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,110V

000021890 / 31436201000 5 OF 5

073

COOLING UPGRADE PACKAGE073

EXT TV ENTERTAINMENT CENTER1DF5 WIRES ARE PART OF WIRE ASM-CHASSIS.

YEL 2

BLK

BLK/YEL

WHT

RED

WHT

BLK

BLK

RED

WIRE SUPPLIEDWITH GENERATOR

2

WHT

GENERATOR

15

12-2

1520

8 GA

POWERCORD

6-3

14-2

GROUND

FRONTROOF AIR

CONDITIONER

14-2

RCP-MICROWAVE

R2

6-3

50

GROUND

RCP-REFRIGERATOR

8 GRN

15 15 15

RCP-CONVERTER

14-2

REARROOF AIR

CONDITIONER

8 GRN

RCP-BSHOWERWALL 2

CHASSISGROUND

14-2 14-2

LOAD CENTER

50

EMS

L2

14-2 14-2

N

R1

12-2

AUTOMATICTRANSFER

SWITCH

L1

8 GRN

20

2RCP-B

SHOWERWALL 3

RCP-GALLEY

RCP-EXT TV

RCP-EXT COMPT1

1DF

RCP-BSIDEWALL

RCP-GALLEY 2

3

RCP-TV 2

RCP-LAVATORY

RCP-HALL

14-2

RCP-BSHOWERWALL 1

RCP-A/V

RCP-BUNDER

DRESSER

RCP-COUNTERTOP

110V CONNECTION(UNDER GALLEY)

RCP-BDRMFRONT

110V CONNECTION(IN SLIDEOUT)

110V CONNECTION(UNDER BED)

RCP-TV1

RCP-COUCH

RCP-DINETTE

RCP-BDRMREAR

RCP-RT,FRT

SIDEWALL

RCP-BRH FRONT

110V CONNECTION(UNDER GALLEY)

3

5 FLEX CORD THROW INWIRE #3

5

THROW INWIRE #2

THROW INWIRE #1

32

RCP-BUNDERGALLEY

FLEX CORD

33