789 789/787B 2 1 2 ProcessMeter™ - Flukeassets.fluke.com/manuals/789_____qreng0100.pdf · injury,...

2
PN 4276679 August 2012, Rev. 1, 1/17 © 2012-2017 Fluke Corporation. All rights reserved. 789/787B ProcessMeter™ Quick Reference Guide XW Warning To prevent possible electrical shock, fire, or personal injury, read the “789/787B Safety Information” before you use this Product. » Consult user documentation. Go to www.fluke.com to register your product and find more information. 0% RANGE HOLD REL MIN MAX Hz 100% 789PROCESSMETER BEEP 1 2 0% RANGE HOLD REL MIN MAX Hz 100% 10 1x = 2x = 3x = 1 2 3 4 x AA Alkaline 0% RANGE HOLD REL MIN MAX Hz 100% 789PROCESSMETER 0% RANGE HOLD REL MIN MAX Hz 100% 789PROCESSMETER 0% RANGE HOLD REL MIN MAX Hz 100% 789PROCESSMETER Fuse 1 Fuse 1 and 2 Fuse Good = <2 MΩ Replace Fuse 1 if reading is OL Check Fuse Use Ohm-meter to test each fuse if reading is . mA Fuse 1 (mA) Fuse 2 (A) 1 2 3 0% RANGE HOLD REL MIN MAX Hz 100% 789PROCESSMETER 0% RANGE HOLD REL MIN MAX Hz 100% 789PROCESSMETER 1 2

Transcript of 789 789/787B 2 1 2 ProcessMeter™ - Flukeassets.fluke.com/manuals/789_____qreng0100.pdf · injury,...

Page 1: 789 789/787B 2 1 2 ProcessMeter™ - Flukeassets.fluke.com/manuals/789_____qreng0100.pdf · injury, read the “789/787B Safety Information” before you use this Product.

PN 4276679 August 2012, Rev. 1, 1/17© 2012-2017 Fluke Corporation. All rights reserved.

789/787BProcessMeter™

Quick Reference GuideXW Warning

To prevent possible electrical shock, fire, or personal injury, read the “789/787B Safety Information” before you use this Product.

» Consult user documentation.

Go to www.fluke.com to register your product and find more information.

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

BEEP

12

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

10

1x =2x =3x =

1

2

3

4 x AAAlkaline

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

Fuse 1 Fuse 1 and 2

Fuse Good = <2 MΩ

Replace Fuse 1 if reading is OL

Check FuseUse Ohm-meter to test each fuse if reading is .

mA

Fuse 1 (mA)Fuse 2 (A)

1

2

3

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

1 2

Page 2: 789 789/787B 2 1 2 ProcessMeter™ - Flukeassets.fluke.com/manuals/789_____qreng0100.pdf · injury, read the “789/787B Safety Information” before you use this Product.

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

Shorted

Reverse BiasForward Bias

Bad DiodeBad Diode

Open

Good Diode Good Diode

1

2

2

2

21

1 1

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

40

20

0 100

80

60

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

40

20

0 100

80

60dc V Power Supply

COM +24V

TEST DC PWR+ –

–+

0%

RANGE HOLD

REL

MIN MAX

Hz

100%

789 PROCESSMETER

for optional250 Ω HART

1 2

= conventional current flow.