7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8"...

16
P7/8-1 7 / 8 " CORRUGATED © Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com Eave Detail .......................................................... P7/8-9 Box Gutter Detail ................................................. P7/8-9 Valley Detail ....................................................... P7/8-10 Rake Detail ........................................................ P7/8-10 Rakewall Detail .................................................. P7/8-11 Endwall Detail .................................................... P7/8-11 Peak Detail ........................................................ P7/8-12 Ridge/Hip Detail................................................. P7/8-12 Gravel Stop Detail ............................................. P7/8-13 Outside Corner Detail ........................................ P7/8-13 Inside Corner Detail ........................................... P7/8-14 Jamb Detail........................................................ P7/8-14 Sill/Head Detail .................................................. P7/8-15 Base Detail ........................................................ P7/8-15 Notes ................................................................. P7/8-16 TABLE OF CONTENTS Product Page No. 7 /8" Corrugated Panel Profiles.............................. P7/8-2 Panel Overview ................................................... P7/8-2 Eave .................................................................... P7/8-3 Cleat .................................................................... P7/8-3 Box Gutter ........................................................... P7/8-3 Box Gutter End .................................................... P7/8-3 Universal Gutter/Downspout Strap ...................... P7/8-3 4" x 3 1 /2" Downspout ............................................ P7/8-3 4" x 3 1 /2" 90° Elbow.............................................. P7/8-3 Downspout Bracket ............................................. P7/8-3 Valley ................................................................... P7/8-3 Rake .................................................................... P7/8-3 Rakewall .............................................................. P7/8-3 Pitch Break .......................................................... P7/8-3 Counter Flashing ................................................. P7/8-3 Reglet Flashing.................................................... P7/8-3 Peak .................................................................... P7/8-3 11" Ridge/Hip Cover ............................................ P7/8-4 Gravel Stop.......................................................... P7/8-4 Outside Corner .................................................... P7/8-4 Inside Corner ....................................................... P7/8-4 1.5" Sill/Head ....................................................... P7/8-4 1.5" Sill to Soffit ................................................... P7/8-4 1.25" Base ........................................................... P7/8-4 Jamb .................................................................... P7/8-4 Universal Closure ................................................ P7/8-5 Tube Sealant ....................................................... P7/8-5 Tape Sealant........................................................ P7/8-5 Rubber Roof Jack ................................................ P7/8-5 Retro Roof Jack ................................................... P7/8-5 Rubber Roof Flash Kit ......................................... P7/8-5 Touch-Up Paint .................................................... P7/8-5 Continuous Ridge Vent ........................................ P7/8-5 Louver with Screen .............................................. P7/8-5 7 /8" Corrugated Closure........................................ P7/8-5 Section Properties (Roof Panel) .......................... P7/8-6 Section Properties (Roof Panel) .......................... P7/8-7 Fasting Patterns .................................................. P7/8-8 Panel Information Flashing Profiles Accessory Profiles Detail Conditions Product Page No. Testing Information Design/Installation Considerations Notes

Transcript of 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8"...

Page 1: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-1

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

Eave Detail ..........................................................P7/8-9Box Gutter Detail .................................................P7/8-9Valley Detail .......................................................P7/8-10Rake Detail ........................................................P7/8-10Rakewall Detail .................................................. P7/8-11Endwall Detail .................................................... P7/8-11Peak Detail ........................................................P7/8-12Ridge/Hip Detail.................................................P7/8-12Gravel Stop Detail .............................................P7/8-13Outside Corner Detail ........................................P7/8-13Inside Corner Detail ...........................................P7/8-14Jamb Detail........................................................P7/8-14Sill/Head Detail ..................................................P7/8-15Base Detail ........................................................P7/8-15

Notes .................................................................P7/8-16

Table of ConTenTs

Product Page No.

7/8" Corrugated Panel Profiles ..............................P7/8-2Panel Overview ...................................................P7/8-2

Eave ....................................................................P7/8-3Cleat ....................................................................P7/8-3Box Gutter ...........................................................P7/8-3Box Gutter End ....................................................P7/8-3Universal Gutter/Downspout Strap ......................P7/8-34" x 31/2" Downspout ............................................P7/8-34" x 31/2" 90° Elbow ..............................................P7/8-3Downspout Bracket .............................................P7/8-3Valley ...................................................................P7/8-3Rake ....................................................................P7/8-3Rakewall ..............................................................P7/8-3Pitch Break ..........................................................P7/8-3Counter Flashing .................................................P7/8-3Reglet Flashing....................................................P7/8-3Peak ....................................................................P7/8-311" Ridge/Hip Cover ............................................P7/8-4Gravel Stop..........................................................P7/8-4Outside Corner ....................................................P7/8-4Inside Corner .......................................................P7/8-41.5" Sill/Head .......................................................P7/8-41.5" Sill to Soffit ...................................................P7/8-41.25" Base ...........................................................P7/8-4Jamb ....................................................................P7/8-4

Universal Closure ................................................P7/8-5Tube Sealant .......................................................P7/8-5Tape Sealant........................................................P7/8-5Rubber Roof Jack ................................................P7/8-5Retro Roof Jack ...................................................P7/8-5Rubber Roof Flash Kit .........................................P7/8-5Touch-Up Paint ....................................................P7/8-5Continuous Ridge Vent ........................................P7/8-5Louver with Screen ..............................................P7/8-57/8" Corrugated Closure........................................P7/8-5

Section Properties (Roof Panel) ..........................P7/8-6Section Properties (Roof Panel) ..........................P7/8-7

Fasting Patterns ..................................................P7/8-8

Panel Information

Flashing Profiles

Accessory Profiles

Detail Conditions

Product Page No.

Testing Information

Design/Installation Considerations

Notes

Page 2: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-2

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

Panel overview

ROOF PANEL PROFILE

SLOPE

SUBSTRATE

COVERAGE

LENGTH

AVAILABILITY

APPLICATION

FASTENING SYSTEM

FASTENERS

MATERIALS

FINISH

The minimum recommended slope for any 7/8" Corrugated panel roofing panel is 1:12.

7/8" Corrugated panel is designed to be utilized over open structural framing, but can easily be used wth a solid substrate. For solid substrate applications, the recommended substrate is 5/8" plywood with a 30 pound felt moisture barrier. To avoid panel distortion, use a properly aligned and uniform substructure.

7/8" Corrugated panel roof coverage is 32", and wall coverage is 342/3".

Lengths under 5'-0" are available with some cutting restrictions. Maximum recommended panel length is 45'-0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult your Metal Sales branch for recommendations (see PGI-2 and 3 for locations).

Panels are available in 26, 24, 22 Gauge. 20 Gauge optional. Minimum quantity may apply.

Commercial, Industrial panel.

Direct fastened (exposed).

The fastener selection guide should be consulted for choosing proper fasteners for specific applications. Quantity and type of fastener must meet necessary loading and code requirements (see PGI-12-14).

Steel grade 50 for 26, 24, and 22 Gauge. Steel Grade 33 for 20 Gauge, per ASTM A-792.

*Acrylic Coated Galvalume® (ACG) / ASTM A-792 - AZ55Prepainted Galvalume / ASTM A-792 - AZ50**Fluorocarbon (PVDF) * Differential appearance of Acrylic Coated Galvalume roofing materials is not a cause for rejection. ** Meets both Kynar 500 and Hylar 5000 specifications.

2 2/3"

WALL PANEL PROFILE

7/8"

C

34 2/3" Coverage

32" Coverage

7/8"

C

2 2/3"

Page 3: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-3

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

Length 10'-2" - *Specify Slope Angle

EAVE

flashing Profiles

C

Hem

3"X*

5/8"

47/8"

VALLEY

C

10"2"

X*

Length 10'-2", 20'-3" - *Specify Slope Angle

BOX GUTTER END UNIVERSAL GUTTER/DOWNSPOUT STRAP

COUNTER FLASHING

1" C

3/4"

3/4"

5/8"

Length 10'-2"3/8"

6"

5" X*

Length 10'-2", 20'-3" - *Specify Slope Angle

CPEAK

BOX GUTTER

Length 10'-2", 20'-3" - *Specify Slope Angle

C

31/2"

5"

1"

1"

Hem

4"

5"

X*

5"

1"

1"4"

5"

11/2"

16"

Hem

DOWNSPOUT 4" x 31/2"

4" 31/2"

C

950 ELBOW 4" x 31/2"

(Also available 6" x 4")

4"

C

31/2"

Length 10'-2", 20'-3"(Also available 6" x 4")

4"

DOWNSPOUT BRACKET

(Also available 6")

C

PITCH BREAK

C

6"

X*4"

Length 10'-2" - *Specify Slope Angle

CLEAT

1/2"

21/2"

C135°

Length 10'-2"

RAKE

Length 10'-2", 20'-3"

C

5/8"

5"

Hem

4"

RAKEWALL

LENGTH 10'-2", 20'-3"

4"

HEM

3 1/2"

C

REGLET FLASHING

1/2"C

1"

2"

Hem

Length 10'-2"

(Also available in 45°)

Page 4: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-4

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

flashing Profiles (ConT.)OUTSIDE CORNER

C- Indicates color side of flashing.

INSIDE CORNER

GRAVEL STOP

1.5" SILL TO SOFFIT

4"

3/8"

51/2"

X*

1/2"C

Length 10'-2", 20'-3" - *Specify Slope Angle

51/2"

51/2"

51/2"

51/2"

C

C

Length 10'-2", 20'-3"

Length 10'-2", 20'-3" Length 10'-2"

C

3/8"

43/4"

1/2"

21/2" 11/2"

11" RIDGE/HIP COVER

C51/2"

X*

Length 10'-2", 20'-3" - *Specify Slope Angle

1.5" SILL/HEAD

Length 10'-2"

C

1" 1/2"

21/2" 11/2"

1.25" BASE

Length 10'-2"

C25/8"

11/4"

5/8"

JAMB

Length 10'-2"

C 1"

21/2"

1"

Page 5: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-5

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

aCCessory Profiles

Available in pintsPVDF / MS Colorfast45

RETRO ROOF JACK RUBBER ROOF

UNIVERSAL CLOSURE

TOUCH-UP PAINT

TUBE SEALANT

10.3 oz. CartridgeUrethane

TAPE SEALANT

MINI (1/4" to 11/8" O.D. Pipe)#2 (13/4" to 3" O.D. Pipe)#4 (3" to 6" O.D. Pipe)#6 (6" to 9" O.D. Pipe)#8 (7" to 13" O.D. Pipe)

RUBBER ROOF JACKFLASH KIT

#801RETRO (3/4" to 23/4" O.D. Pipe)#802RETRO (2" to 71/4" O.D. Pipe)#803RETRO (31/4" to 10" O.D. Pipe)

12" x 50'-0" Flash Kit18" x 50'-0" Flash Kit

1" x 11/2" x 50' Polyethylene Foam1" x 11/2" x 10' Polyethylene Foam

3/8" X 3/32" X 50'Single BeadButyl - Gray

9" X 10'-0"12" X 10'-0"

CONTINUOUS RIDGE VENT

3'-0" X 3'-0"3'-0" X 4'-0"

LOUVER WITH SCREEN

Polyethylene Foam

CORRUGATED CLOSURE

Page 6: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-6

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

seCTion ProPerTies & general informaTion (roof Panel)

1. Section properties and allowable loads are calculated per AISI 2001 including 2004 Supplement.2. Ixx and Sxx are effective section properties for deflection and bending3. Allowable loads/spans are calculated considering bending, shear, combined bending and shear and deflection.4. Allowable loads/spans calculations do not include consideration for web crippling, fastener / connection limitations or uplift testing.5. Allowable loads/spans do not include a 1/3 stress increase.6. Allowable loads for 24 ga on 16 ga purlins are based on ASTM E 1592 test results.

ALLOWABLE UNIFORM LIVE LOADS PSF(3 or More Equal Spans)

2' 2.5' 3' 3.5' 4' 5' 2' 2.5' 3' 3.5' 4' 5'

SECTION PROPERTIES

Bottom in CompressionWidth(in.)

YieldKSI

32" 80

32" 50

32" 50

32" 33

26

Ga.

242220

SxxIn3/ft

IxxIn4/ft

WeightPSF

1.02

1.33

1.73

2.11

Top in Compression

SxxIn3/ft

IxxIn4/ft

0.0278 0.0624 0.0278 0.0624 418 272 170 107 72 37 418 272 170 107 72 37

0.0338 0.0801 0.0338 0.0801 156 143 131 113 99 80 156 143 131 113 99 80

0.0450 0.1029 0.0450 0.1029 574 373 262 173 116 59 574 373 262 173 116 59

0.0525 0.1234 0.0525 0.1234 454 295 207 153 117 69 454 295 207 153 117 69

Inward Load

OutwardLoad

Slope

Substructure

Coverage

Length

Fastener

Availability

GENERAL INFORMATIONROOF ATTACHMENT

FASTENING PATTERNS

The minimum recommended slope for 7/8" Corrugated roofing panel is 1:12.

7/8" Corrugated panel is designed to be utilized over open structural framing but can easily be used with a solid substrate. To avoid panel distortion use a properly aligned and uniform substructure.

7/8" Corrugated panel has a coverage width of 32"

Minimum factory cut length is 3'-0". Maximum recommended panel length is 45'-0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult Metal Sales for recommendations.

The fastener selection guide should be consulted for choosing the proper fastener for specific applications. Quantity and type of fastener must meet necessary loading and code requirements NOTE: All panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the face of the panel at or near the point of attachment.

Finishes: Bare galvanized, MS Colorfast45®, PVDF, Weathering Steel, and Acrylic Coated Galvalume® Gauges: 26ga and 24ga standard, 22ga and 20ga optional

ROOF

Tape Sealant

#12-14 Self Drillerat supports

Stitch Screw (1'-0" o.c.)between supports

#12-14 Self Driller (4 per Panel)

2 2/3"32" Coverage

7/8"

C

Page 7: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-7

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

1. Section properties and allowable loads are calculated per AISI 2001 including 2004 Supplement.2. Ixx and Sxx are effective section properties for deflection and bending3. Allowable loads/spans are calculated considering bending, shear, combined bending and shear and deflection.4. Allowable loads/spans calculations do not include consideration for web crippling, fastener / connection limitations or uplift testing.5. Allowable loads/spans do not include a 1/3 stress increase.6. Allowable loads for 24 ga. are based on ASTM E 330 test results attaching to 16 ga. girts

ALLOWABLE UNIFORM LIVE LOADS PSF(3 or More Equal Spans)

2’ 3’ 4’ 5’ 6’ 7’ 2’ 3’ 4’ 5’ 6’ 7’

SECTION PROPERTIES

Bottom in CompressionWidth(in.)

YieldKSI

34.67" 80

34.67" 50

34.67" 50

34.67" 33

26

Ga.

242220

SxxIn3/ft

IxxIn4/ft

WeightPSF

0.94

1.22

1.60

1.95

Top in Compression

SxxIn3/ft

IxxIn4/ft

0.0255 0.0580 0.0255 0.0580 386 156 66 34 20 8 386 156 66 34 20 8

0.0330 0.0744 0.0330 0.0744 175 151 127 102 78 30 175 151 127 102 78 30

0.0413 0.0956 0.0413 0.0955 530 241 107 55 32 13 530 241 107 55 32 13

0.0488 0.1146 0.0488 0.1146 419 191 108 64 37 16 419 191 108 64 37 16

Inward Load

OutwardLoad

Substructure

Coverage

Length

Fastener

Availability

GENERAL INFORMATIONWALL ATTACHMENT

FASTENING PATTERN

7/8" Corrugated panel is designed to be utilized over open structural framing but can easily be used with a solid substrate. To avoid panel distortion use a properly aligned and uniform substructure.

7/8" Corrugated panel has a coverage width of 34 2/3"

Minimum factory cut length is 3'-0". Maximum recommended panel length is 45'-0". Longer panels require additional consideration in packaging, shipping, and erection. Please consult Metal Sales for recommendations.

The fastener selection guide should be consulted for choosing the proper fastener for specific applications. Quantity and type of fastener must meet necessary loading and code requirements NOTE: All panels are subject to surface distortion due to improperly applied fasteners. Overdriven fasteners will cause stress and induce oil canning across the face of the panel at or near the point of attachment.

Finishes: Bare galvanized, MS Colorfast45®, PVDF, Weathering Steel, and Acrylic Coated Galvalume® Gauges: 26ga, 24ga, 22ga, and 20ga

WALL

#12-14 Self Driller

2 2/3"34 2/3" Coverage

7/8"

C

seCTion ProPerTies & general informaTion (wall Panel)

Page 8: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-8

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

Design / insTallaTion ConsiDeraTions (ConT.)

#12-14 x 11/4" Self Driller

ROOF PANEL FASTENING PATTERN

WALL PANEL FASTENING PATTERN

#12-14 x 2" Self Driller

Tape Sealant

Page 9: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-9

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

eave DeTail

box guTTer DeTail

1:12 SlopeMinimum

Tape Sealant

7/8" Corrugated Roof Panel

Eave

#12-14 x 2" Self Driller (See Below)

7/8" CorrugaTeD1:12 SlopeMinimum

Closure

Tape Sealant

Box Gutter

Universal Gutter/Downspout Strap

Closure

1/8" x 3/16" Pop-Rivet (every strap)

7/8" Corrugated Wall Panel

7/8" Corrugated Roof Panel

7/8" Corrugated Wall Panel

Closure

1/4"-14 x 7/8" Stitch Screw (1'-0" o.c.)

Closure

#12-14 x 11/4" Self Driller

#12-14 x 2" Self Driller (See Below)

#12-14 x 11/4" Self Driller

Tape Sealant#12-14 x 2" Self Driller

7/8" Corrugated Roof Fastening Pattern

Tape Sealant#12-14 x 2" Self Driller

7/8" Corrugated Roof Fastening Pattern

Page 10: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-10

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

valley DeTail

rake DeTail

1:12 SlopeMinimum

Tape Sealant

Valley

7/8" CorrugaTeD

Universal Closure

3" Minimum

Tape Sealant

Rake

Closure

7/8" Corrugated Wall Panel

7/8" Corrugated Roof Panel

7/8" Corrugated Roof Panel

1/4"-14 x 7/8" Stitch Screw (1'-0" o.c.)

Tape Sealant

Valley Plate

#12-14 x 2" Self Driller (See Below)

#12-14 x 2" Self Driller (1'-0" o.c.)

Rake Angle

#12-14 x 11/4" Self Driller

Tape Sealant#12-14 x 2" Self Driller

7/8" Corrugated Roof Fastening Pattern

CL

Page 11: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-11

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

rakewall wiTh wall Panel DeTail

enDwall wiTh wall Panel DeTail

1:12 SlopeMinimum

Tape Sealant

Rakewall

7/8" CorrugaTeD1:12 SlopeMinimum

Closure

Tape Sealant

Pitch Break

Closure

7/8" Corrugated Roof Panel

7/8" Corrugated Wall Panel

7/8" Corrugated Roof Panel

7/8" Corrugated Wall Panel

#12-14 x 2" Self Driller (1'-0" o.c.)

#12-14 x 11/4" Self Driller (See Below)

Rake Angle

#12-14 x 2" Self Driller (See Below)

#12-14 x 11/4" Self Driller

Tape Sealant#12-14 x 2" Self Driller

7/8" Corrugated Roof Fastening Pattern

Tape Sealant#12-14 x 2" Self Driller

7/8" Corrugated Roof Fastening Pattern

Page 12: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-12

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

Peak DeTail

riDge/hiP DeTail

1:12 SlopeMinimum

Tape Sealant

Peak

7/8" CorrugaTeD1:12 SlopeMinimum

Universal Closure

Tape Sealant

11" Ridge/Hip Cover

Closure*

7/8" Corrugated Roof Panel

7/8" Corrugated Roof Panel

#12-14 x 2" Self Driller (See Below)

#12-14 x 11/4" Self Driller

1/4"-14 x 7/8" Stitch Screw (1'-0" o.c.)

#12-14 x 2" Self Driller (See Below)

* Standard Formed Closure for ridge. Universal Closure for hip.

Tape Sealant#12-14 x 2" Self Driller

7/8" Corrugated Roof Fastening Pattern

Tape Sealant#12-14 x 2" Self Driller

7/8" Corrugated Roof Fastening Pattern

Page 13: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-13

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

gravel sToP DeTail

ouTsiDe Corner DeTail

Tape Sealant

Gravel Stop

Fastener (by others)

7/8" CorrugaTeD

Closure

Tape Sealant

Outside Corner

7/8" Corrugated Wall Panel

7/8" Corrugated Wall Panel

1/4"-14 x 7/8" Stitch Screw (1'-0" o.c.)

1/4"-14 x 7/8" Stitch Screw (1'-0" o.c.)

#12-14 x 11/4" Self Driller

#12-14 x 11/4" Self Driller

Page 14: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-14

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

insiDe Corner DeTail

Jamb DeTail

Tape Sealant

Inside Corner

7/8" CorrugaTeD

Jamb

7/8" Corrugated Wall Panel

7/8" Corrugated Wall Panel

1/4"-14 x 7/8" Stitch Screw (1'-0" o.c.)

#12-14 x 11/4" Self Driller

#12-14 x 11/4" Self Driller (1'-0" o.c.)

Page 15: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-15

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

sill/heaD DeTail

base DeTail

Tape Sealant

7/8" CorrugaTeD

Closure

11/2" Sill/Head

Tape Sealant

11/4" Base

Closure

7/8" Corrugated Wall Panel

7/8" Corrugated Wall Panel

#12-14 x 11/4" Self Driller (See Below)

Tape Sealant#12-14 x 2" Self Driller

7/8" Corrugated Roof Fastening Pattern

#12-14 x 11/4" Self Driller (See Below)

Tape Sealant#12-14 x 2" Self Driller

7/8" Corrugated Roof Fastening Pattern

Page 16: 7 CORRUGATED able of onTenTs - Metal Sales...8" Corrugated panel roofing panel is 1:12. 7/ 8" Corrugated panel is designed to be utilized over open structural framing, but can easily

P7/8-16

7/8" CORRUGATED

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11 800.406.7387 (Corporate Office) • www.metalsales.us.com

noTes