TH9000 Series Equipment Interface Module Installation Guide 69-2406EFS-01 ® U.S. Registered Trademark. US Patent No. 6,208,263; 6,373,376; 6,448,901; 7,012,927 and other patents pending. Copyright © 2010 Honeywell International Inc. All rights reserved. English: Page 1 • Français: Page 6 • Español: Página 11 For up to 4 Heat/2 Cool systems with Equipment Interface Module or equivalent. System Types CAUTION: ELECTRICAL HAZARD. Can cause electrical shock or equipment damage. Disconnect power before beginning installation. MERCURY NOTICE: If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste manage- ment authority for instructions regarding recycling and proper disposal. Must be installed by a trained, experienced technician Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. Gas, oil, or electric heat with air conditioning Warm air, hot water, high- efficiency furnaces, heat pumps, steam, gravity Heat only Heat only with fan Cool only

Transcript of 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3...

Page 1: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

TH9000 SeriesEquipment Interface Module

Installation Guide

69-2406EFS-01

® U.S. Registered Trademark. US Patent No. 6,208,263; 6,373,376; 6,448,901; 7,012,927 and other patents pending.

Copyright © 2010 Honeywell International Inc. All rights reserved.

English: Page 1 • Français: Page 6 • Español: Página 11

For up to 4 Heat/2 Cool systems with Equipment Interface Module or equivalent.

System Types

CAUTION: ELECTRICAL HAZARD. Can cause electrical shock or equipment damage. Disconnect power before beginning installation.

MERCURY NOTICE: If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste manage-ment authority for instructions regarding recycling and proper disposal.

Must be installed by a trained, experienced technicianRead these instructions carefully. Failure to follow these instructions

can damage the product or cause a hazardous condition.

• Gas,oil,orelectricheatwithairconditioning

• Warmair,hotwater,high-efficiency furnaces, heat pumps, steam, gravity

• Heatonly

• Heatonlywithfan

• Coolonly

Page 2: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

TH9000 Series Equipment Interface Module

69-2406EFS—01 2

Installation

1 Remove cover from Equipment Interface Module (EIM).

2 EIM can be mounted on equipment or on wall. Use included wall anchors for mounting onto drywall (drill 3/16" holes for drywall; 7/32" holes for plaster).

Wiring

Connect wires as shown below (see wiring guides on following pages).

CAUTION: This product may be damaged if mounted inside HVAC equipment. Install only on the outside of HVAC equipment.

M29796

LED

Restore power and check LED:

• LEDblinksrapidly:Normalinformationtransfer.

• LEDblinksonce:IncomingmessagetoEIM.

• LEDblinkscontinuously:Wiringproblem.Check wiring to terminals 1, 2, 3.

• LEDalwaysoff:Wiringproblem.Checkwiring to terminals 1, 2, 3.

• LEDalwayson:EIMmayneedreplacement.

NOTE: It is normal for the LED to blink continuously during startup, and while checking equipment status (Auto Discover mode).

Page 3: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

English: Page 1 • Français: Page 6 • Español: Página 11

3 69-2406EFS—01

Wiring guide

M23487

FACTORY INSTALLED JUMPER BETWEEN R, RC AND RH

123CRRCRH

COMMUNICATIONTERMINALS

COMMUNICATION LED

W1W2W3YY2G

24 VAC

O/BAUXAUX2YY2G

123

CONV. HP

HEAT 1 RELAY

HEAT 2 RELAY

HEAT 3 RELAY

COOL 1 RELAY

COOL 2 RELAY

FAN RELAY

WIRE TO TERMINALS ON THERMOSTAT.1

1

Typical hookup of conventional system with up to three-stage heat and two-stage cool with one transformer (3H/2C, 2H/2C, 2H/1C, 1H/2C, 1H/1C, 1H, 2H, 3H, 1C, 2C conventional).

M23490

1

2

3

C

R

RC

RH

24 VAC

H1UM2D1HM2V1N T2

OR

POWEREDHUMIDIFIER

Typical hookup of powered humidifier.

M23488

FACTORY INSTALLED JUMPER BETWEEN R, RC AND RH

123CRRCRH

COMMUNICATIONTERMINALS

COMMUNICATION LED

W1W2W3YY2G

24 VAC

O/BAUXAUX2YY2G

123

CONV. HP

CHANGEOVER

AUX 1 (HEAT 3)

AUX 2 (HEAT 4)

COMP 1

COMP 2

FAN RELAY

WIRE TO TERMINALS ON THERMOSTAT.1

1

Typical hookup of heat pump system with up to four-stage heat and two-stage cool with one transformer (4H/2C, 3H/2C, 2H/2C, 2H/1C, 1H/1C heat pump systems).

Wiring guide—equipment

With power supply Without power supply

M23489

FIELD INSTALLED JUMPER BETWEEN R AND HUM 1

1

2

3

C

R

RC

RH

24 VAC

H1UM2D1HM2V1N T2

OR

NON-POWEREDHUMIDIFIER

Typical hookup of non-powered humidifier.

Page 4: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

TH9000 Series Equipment Interface Module

69-2406EFS—01 4

M23493

FIELD INSTALLED JUMPER BETWEEN R AND VNT 1

1

2

3

C

R

RC

RH

24 VAC

H1UM2D1HM2V1N T2

OR

NON-POWEREDVENTILATOR

Typical hookup of non-powered ventilation.

M23491

FIELD INSTALLED JUMPER BETWEEN R AND DHM 1

1

2

3

C

R

RC

RH

24 VAC

H1 U M2

D1 H M2

V1 N T2

OR LOW SPEED FAN

Typical hookup of variable speed blower for dehumidification in low speed.

M23494

1

2

3

C

R

RC

RH

24 VAC

H1UM2D1HM2V1N T2

OR

POWEREDVENTILATOR

Typical hookup of powered ventilation.

M23492

1

2

3

C

R

RC

RH

24 VAC

H1UM2D1HM2V1N T2

ORPOWEREDDEHUMIDIFIER

Typical hookup of powered dehumidifier (whole house dehumidifier).

Wiring guide—equipment

With power supply Without power supply

M23685

KEY

= NORMALLY OPEN, DRY CONTACTS

= NORMALLY CLOSED, DRY CONTACTS

Page 5: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

English: Page 1 • Français: Page 6 • Español: Página 11

5 69-2406EFS—01

Specifications

Temperature Ranges• Heat:40°to90°F(4.5°to32°C)• Cool:50°to99°F(10°to37°C)

Operating Ambient Temperature• -30°to150°F(-34to66°C)

Shipping Temperature• -30°to150°F(-34to66°C)

Operating Relative Humidity• 5%to90%(non-condensing)

Physical Dimensions• 7-9/16"Hx4-35/64"Wx1-21/64"D 185mmHx116mmWx34mmD

Electrical Ratings

Terminal Voltage(50/60Hz) RunningCurrent

W Heating 20-30 Vac 0.02-1.0 A

W2 Heating 20-30 Vac 0.02-1.0 A

W3 Heating 20-30 Vac 0.02-1.0 A

Y Cooling 20-30 Vac 0.02-1.0 A

Y2 Cooling 20-30 Vac 0.02-1.0 A

AuxAuxiliaryHeat 20-30Vac 0.02-1.0A

Aux2AuxiliaryHeat 20-30Vac 0.02-1.0A

G Fan 20-30 Vac 0.02-1.0 A

O/B Changeover 20-30 Vac 0.02-1.0 A

Page 6: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

TH9000 SérieEquipment Interface Module

Guide d’installation

English: Page 1 • Français: Page 6 • Español: Página 11

Pour installations comportant 4 circuits de chauffage/2 circuits de climatisation avec Equipment Interface Module ou équivalent.

Types d’installations• Chauffageaugaz,aumazoutou

électrique avec climatisation

• Chaudièresàhautrendementàairchaud,eauchaude,thermopompes, vapeur, calorifères

• Chauffageseulement

• Chauffageseulementavecventilateur

• Climatisationseulement

® U.S. Marque déposée Brevets US N0. 6 208 263; 6 373 376; 6 448 901; 7 012 927 et autres brevets en instance.

Copyright © 2010 Honeywell International Inc. Tous droits réservés.

MISE EN GARDE : RISQUE ÉLECTRIQUE. Peut provoquer des secousses électriques ou endommager le matériel. Coupez l’alimentation avant d’entreprendre l’installation.

AVIS CONCERNANT LE MERCURE : Si ce produit remplace un dispositif de régula-tion contenant une ampoule de mercure, ne placez pas ce dernier dans les ordures. Contactezl'agencedegestiondesdéchetsdelalocalitépourconnaîtrelesrèglementsconcernant le recyclage et la mise au rebut.

Doit être installé par un technicien expérimenté et qualifié.Lireattentivementcesinstructions.Lemanquementàsuivrecesinstructionspeut entraîner des dommages au produit et causer des conditions dangereuses.

Page 7: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

TH9000 SérieEquipment Interface Module

English: Page 1 • Français: Page 6 • Español: Página 11

7 69-2406EFS—01

Installation

1 Enlevez la couverture de Equipment Interface Module (EIM).

2 Le module d’interface peut être installé sur le matériel ou au mur. Utiliser les chevilles d’ancrage fournies pour une installation sur un mur de placoplâtre (percer des ouvertures de 3/16 po dans un mur de placoplâtre; percer des ouvertures de 7/32 po dans un mur de plâtre).

Câblage

Reliezlesfilscommemontrésci-dessous(voirlesguidesdecâblageauxpagessuivantes).

ATTENTION :Pouréviterdesdommages,n'installezpasceproduitàl'intérieurd'équipementdelaHVAC.Installezseulementsurl'extérieurdel'équipementdelaHVAC.

M29796

LED

Reconstituerez l'énergie électrique & vérifiez l'opération :

• Lalumièreclignoterapidement:Transfertdel'information normal.

• Clignotementsdelumièreunefois:MessageentrantàEIM.

• Lalumièreclignotesansinterruption:Problèmedecâblage.Vérifiezlecâblageauxbornes 1, 2, 3.

• Lumièretoujoursauloin:Problèmedecâblage.Vérifiezlecâblageauxbornes 1, 2, 3.

• Lumièretoujoursdessus:EIMpeutavoirbesoin de remplacement.

REMARQUE : Il est normal que la LED clignote sans interruption pendant le démarrage, et tout en vérifiant le statut d'équipement (le mode Auto Discover).

Page 8: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

TH9000 Series Equipment Interface Module

69-2406EFS—01 8

Guide de câblage

MF23487

CAVALIER INSTALLÉ À L’USINEENTRE R, RC ET RH

1 2 3 C R RC RH

BORNES DECOMMUNICATION

VOYANT DE COMMUNICATION

W1 W2 W3 Y Y2 G

24 VCA

O/B AUX AUX2 Y Y2 G

1 2 3

CONV. HP

RELAIS DE CHAUFFAGE 1

RELAIS DE CHAUFFAGE 2

RELAIS DE CHAUFFAGE 3

RELAIS DE REFROID. 1

RELAIS DE REFROID. 2

RELAIS DE VENTILATEUR

FIL VERS LES BORNES DU THERMOSTAT.1

1

Raccordementtyped’unsystèmeclassiqueoffrantjusqu’à3étagesdechauffage et 2 étages de refroidissement avec un transformateur

(3C/2R, 2C/2R, 2C/1R, 1C/2R, 1C/1R, 1C, 2C, 3C, 1R, 2R classique).

MF23490

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

OU

HUMIDIFICATEURALIMENTÉ

Raccordement type d’un humidificateur alimenté.

MF23488

CAVALIER INSTALLÉ À L’USINEENTRE R, RC ET RH

1 2 3 C R RC RH

BORNES DECOMMUNICATION

VOYANT DE COMMUNICATION

W1 W2 W3 Y Y2 G

24 VCA

O/B AUX AUX2 Y Y2 G

1 2 3

CONV. HP

COMMUTATIONCHAUD-FROID

AUX 1 (CHAUFFAGE 3)

AUX 2 (CHAUFFAGE 4)

COMP 1

COMP 2

RELAIS DE VENTILATEUR

FIL VERS LES BORNES DU THERMOSTAT.1

1

Raccordementtyped’unsystèmeavecthermopompeàuntransformateuroffrant jusqu’àquatreétagesdechauffageetdeuxétagesderefroidissementet

(thermopompes 4C/2R, 3C/2R, 2C/2R, 2C/1R, 1C/1R).

Guide de raccordement – matériel

Avec alimentation électrique Sans alimentation électrique

MF23489

CAVALIER INSTALLÉÀ L’USINE ENTRER ET HUM1

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

OU

HUMIDIFICATEURNON ALIMENTÉ

Raccordement type d’un humidificateur non alimenté.

Page 9: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

English: Page 1 • Français: Page 6 • Español: Página 11

9 69-2406EFS—01

MF23493

CAVALIER INSTALLÉÀ L’USINE ENTRE RET VNT1

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

OU

VENTILATEURNON ALIMENTÉ

Raccordement type d’un ventilateur non alimenté.

MF23491

CAVALIER INSTALLÉÀ L’USINE ENTRER ET HUM1

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

OUVENTILATEUR ÀFAIBLE VITESSE

Raccordementtyped’unventilateuràvitessevariableservantàladéshumidificationàfaiblevitesse.

MF23494

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

OU

VENTILATEURALIMENTÉ

Raccordement type d’un ventilateur alimenté.

MF23492

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

OUDÉSHUMIDIFICATEURALIMENTÉ

Raccordement type d’un déshumidificateur alimenté (déshumidificateur pour toute la maison).

Guide de raccordement – matériel

Avec alimentation électrique Sans alimentation électrique

CLÉ

MF23685

= CONTACTS SECS, NORMALEMENT OUVERTS

= CONTACTS SECS, NORMALEMENT FERMÉS

Page 10: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

TH9000 Series Equipment Interface Module

69-2406EFS—01 10

Caractéristiques techniques

Gammes de température• Chauffage:4,5°à32°C

(40°à90°F)• Climatisation:10°à37°C

(50°à99°F)

Température ambiante de fonc-tionnement

• -34°à66°C(-30°à150°F)

Température d’expédition• -34°à66°C(-30°à150°F)

Humidité relative de fonctionnement• 5%à90%(sincondensación)

Dimensions• 7-9/16"Hx4-35/64"Lx1-21/64"Ép 185mmHx116mmLx34mmÉp

Caractéristiques électriques

Borne Tension(50/60Hz) Courant

W Chauffage 20-30 Vca 0,02-1,0 A

W2 Chauffage 20-30 Vca 0,02-1,0 A

W3 Chauffage 20-30 Vca 0,02-1,0 A

Y Climatisation 20-30 Vca 0,02-1,0 A

Y2 Climatisation 20-30 Vca 0,02-1,0 A

Aux Chauffageaux 20-30 Vca 0,02-1,0 A

Aux2 Chauffageaux 20-30 Vca 0,02-1,0 A

G Ventilateur 20-30 Vca 0,02-1,0 A

O/B Inversion 20-30 Vca 0,02-1,0 A

Page 11: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

TH9000 SerieEquipment Interface Module

Guía de instalación

English: Page 1 • Français: Page 6 • Español: Página 11

Parahasta4sistemasdecalefacción/2derefrigeraciónconEquipmentInterfaceModule o equivalente.

Tipos de sistemas

• Calefacciónagas,petróleooeléctrica con aire acondicionado

• Airecaliente,aguacaliente,estufas de alta eficiencia, bombasdecalefacción,vapor,gravedad

•Sólocalefacción

•Sólocalefacciónconventilador

•Sólorefrigeración

® Marca registrada en EE.UU. Patente en EE.UU: Nº 6,208,263; 6,373,376; 6,448,901; 7,012,927 y otras patentes pendientes.

Copyright © 2010 Honeywell International Inc. Todos los derechos reservados.

PRECAUCIÓN: PELIGRO ELÉCTRICO. Puede causar descarga eléctrica o daño del equipo.Desconectelaalimentacióndeenergíaantesdeiniciarlainstalación.

AVISO DE MERCURIO: Si este producto reemplaza a un control que contiene mer-curioenuntubosellado,noarrojeelcontrolviejoalabasura.Comuníqueseconlaautoridadlocaldedisposicióndedesechospararecibirinstruccionessobrerecicladoyeliminacióncorrecta.

Debe ser instalado por un técnico capacitado y experimentado

Lea estas instrucciones atentamente. Si no sigue estas instrucciones, puede dañar el producto u ocasionar un riesgo.

Page 12: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

TH9000 Series Equipment Interface Module

69-2406EFS—01 12

Instalación

1 Quite la cubierta de Equipment Interface Module (EIM).

2 ElEIMpuedemontarseenelequipooenlapared.Utilicelasanclasdeexpansiónparaelmontajesobretablarroca(entablarroca,realiceagujerosde3/16”yenyeso,de7/32”).

Cableado

Conecteloscablessegúnlodemostradoabajo(verlasguíasdecableadoenlaspáginassiguientes).

PRECAUCIÓN: Para evitar daño, no instale este producto dentro del equipo de la HVAC.InstalesolamenteenelexteriordelequipodelaHVAC.

M29796

LED

Reactivaron corriente eléctrica y verifique la operación:

• Laluzcentelleorápidamente:Transmisióninformativa normal.

• Centelleosdelaluzunavez:Mensajeentrante a EIM.

• Laluzcentelleocontinuamente:Problemadel cableado. Compruebe el cableado a los terminales 1, 2, 3.

• Luzsiempreapagado:Problemadelcableado. Compruebe el cableado a los terminales 1, 2, 3.

• Luzsiempreencendido:EIMpuedenecesitarel reemplazo.

NOTA: Es normal para que la luz centelleo continuamente durante arranque, y mientras que comprueba estado del equipo (el modo Auto Discover).

Page 13: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

English: Page 1 • Français: Page 6 • Español: Página 11

13 69-2406EFS—01

Guía de cableado

MS23487

PUENTE INSTALADO ENFÁBRICA ENTRE R, RC Y RH

1 2 3 C R RC RH

TERMINALES DECOMUNICACIÓN

LED DE COMUNICACIÓN

W1 W2 W3 Y Y2 G

24 VCA

O/B AUX AUX2 Y Y2 G

1 2 3

CONV. HP

RELÉ DE CALOR 1

RELÉ DE CALEFACCIÓN 2

RELÉ DE CALEFACCIÓN 3

RELÉ DE REFRIG. 1

RELÉ DE REFRIG. 2

RELÉ DEL VENTILADOR

CABLE A TERMINALES EN EL TERMOSTATO.1

1

Conexióntípicadelsistemaconvencionalconcalordehastatresetapasyfrío de hasta dos etapas con un transformador

(convencional de 3C/2R, 2C/2R, 2C/1R, 1C/2R, 1C/1R, 1C, 2C, 3C, 1R, 2R).

MS23490

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

O

HUMIDIFICADOR CON ENERGÍA

Conexióntípicadehumidificadorconenergía.

MS23488

PUENTE INSTALADO ENFÁBRICA ENTRE R, RC Y RH

1 2 3 C R RC RH

TERMINALES DECOMUNICACIÓN

LED DE COMUNICACIÓN

W1 W2 W3 Y Y2 G

24 VCA

O/B AUX AUX2 Y Y2 G

1 2 3

CONV. HP

CONVERSIÓN

AUX 1 (CALEFACCIÓN 3)

AUX 2 (CALEFACCIÓN 4)

RELÉ DE REFRIG. 4

RELÉ DE REFRIG. 5

RELÉ DEL VENTILADOR

CABLE A TERMINALES EN EL TERMOSTATO.1

1

Conexióntípicadelsistemadebombadecalorconuntransformador, concalordehastacuatroetapasyfríodehastadosetapas

(sistemas de bombas de calor 4C/2R, 3C/2R, 2C/2R, 2C/1R, 1C/1R).

Guía de cableado—equipo

Con suministro de energía Sin suministro de energía

MS23489

PUENTE INSTALADOEN CAMPO ENTRER Y HUM 1

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

O

HUMIDIFICADOR SIN ENERGÍA

Conexióntípicadehumidificadorsinenergía.

Page 14: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

TH9000 Series Equipment Interface Module

69-2406EFS—01 14

MS23493

PUENTE INSTALADOEN CAMPO ENTRER Y VNT 1

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

O

VENTILADORSIN ENERGÍA

Conexióntípicadeventilaciónsinenergía.

MS23491

PUENTE INSTALADOEN CAMPO ENTRER Y DHM 1

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

OVENTILADOR DEBAJA VELOCIDAD

Conexióntípicadelventiladorde velocidadvariableparadeshumidificación abajavelocidad.

MS23494

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

O

VENTILADORCON ENERGÍA

Conexióntípicadeventilaciónconenergía.

MS23492

1

2

3

C

R

RC

RH

24 VCA

H1 U M2

D1 H M2

V1 N T2

ODESHUMIDIFICADORCON ENERGÍA

Conexióntípicadedeshumidificadorconenergía(deshumidificadordehogares).

Guía de cableado—equipo

Con suministro de energía Sin suministro de energía

TECLA

MS23685

= CONTACTOS SECOS, NORMALMENTE ABIERTOS

= CONTACTOS SECOS, NORMALMENTE ABIERTOS

Page 15: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

English: Page 1 • Français: Page 6 • Español: Página 11

15 69-2406EFS—01

Especificaciones

Rangos de temperatura• Calefacción:40°a90°F

(4,5°a32°C)• Refrigeración:50°a99°F

(10°a37°C)

Temperatura ambiental de funcionamiento

• -30°a150°F(-34°a66°C)

Temperatura de envío• -30°a150°F(-34°a66°C)

Humedad relativa de funcionamiento• 5%a90%(sincondensación)

Dimensiones físicas• 7-9/16"Hx4-35/64"Ax1-21/64"P 185mmHx116mmAx34mmP

Regímenes eléctricos

Terminal Tensión(50/60Hz) Corriente

WCalefacción 20-30VCA 0,02-1,0 A

W2Calefacción 20-30VCA 0,02-1,0 A

W3Calefacción 20-30VCA 0,02-1,0 A

YRefrigeración 20-30VCA 0,02-1,0 A

Y2Refrigeración 20-30VCA 0,02-1,0 A

AuxCalefacciónaux. 20-30VCA 0,02-1,0 A

Aux2Calefacciónaux. 20-30VCA 0,02-1,0 A

G Ventilador 20-30 VCA 0,02-1,0 A

O/B Cambio 20-30 VCA 0,02-1,0 A

Page 16: 69-2406EFS-01 - TH9000 Series · english: page 1 • français: page 6 • español: página 11 3 69-2406efs—01 wiring guide m23487 factory installed jumper between r, rc and rh

Installation Guide

® U.S. Registered Trademark.© 2010 Honeywell International Inc.69-2406EFS—01 M.S. 01-10Printed in U.S.A.

Need Help?For assistance with this product please call Customer Care toll-free at

1-800-468-1502

Besoin d’aide?Pourobtenirdel’aideetapprendreàfairefonctionnervotreproduit, adresserauxServicesàlaclientèleencomposantle1800468-1502

¿Necesita ayuda?Llamandosincargoaatenciónalcliente1-800-468-1502