64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning...

21
64 Slice CT Scanner for all purpose scanning including coronary Angiography. The system is to be bought on buy back basis of the existing CT scan machine in the department of radiology .The buy back is mandatory. The vendor will have to take the machine in its existing condition on their own & install new machine. The tenders are invited for installation of 64 Slice s of detector CT Scan at 1) Shri V.N.Govt. Medical College, Yavatmal 2) S.R.T.R. Rural Medical College & Hospital, Ambajogai 3) Govt. Medical College & Hospital, Akola It is mandatory for the tenderers to quote in the commercial bid as mentioned below - 1) Cost of 64 Slice of detector CT Scanner with all accessories as per specifications 2) Buy back cost for the existing CT Scan in the department 3) Turn Key cost separately for above mentioned 2 institutes 4) The Price of films required for dry camera 5) CMC cost inclusive of CT Tube for seven years post warranty period. 6) CMC cost exclusive of CT Tube for seven years post warranty period. 7) Price of the CT Tube should be quoted separately. These prices will be freezed for seven years Note :- GMC, Akola needs only 64 Slice CT Scanner on buy back basis without Turnkey (No need to quote turnkey cost for GMC, Akola) A complete multislice helical CT scanner with all necessary software & hardware required to perform various clinical protocols. It should be DICOM ready with capability of transferring images to the hospital PACS, all cost born by company. The software upgrades or system improvement must be provided during warranty period and CMC. The vendor should indicate & include recent any technological advances that arent mentioned here but are appropriate for the system. Describe all work in progress. Detector Detector should acquire 64 slice in one rotation It should have 64 rows of detectors Please specify the number of elements in each row. Mention the Z axis coverage. The scan length available should at least be 40cm. Indicate the maximum reference scan length. Cone beam correction should be present Solid state detectors. Spiral Acquisition a) Scan time should be 0.4 sec. or less, for full 360 deg. rotation. b) Specify time in minutes for warm up from fully off in normal as well as emergency. c) Minimum slice thickness 0.625 mm. or less. Specify minimum slice thickness in axial, spiral and cardiac modes. d) Specify the pitch factor for general radiological application. For cardiac scanning pitch should be 0.2 or less

Transcript of 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning...

Page 1: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

64 Slice CT Scanner for all purpose scanning including coronary Angiography.

The system is to be bought on buy back basis of the existing CT scan machine in the department of radiology .The buy back is mandatory. The vendor will have to take the machine in its existing condition on their own & install new machine. The tenders are invited for installation of 64 Slice s of detector CT Scan at 1) Shri V.N.Govt. Medical College, Yavatmal 2) S.R.T.R. Rural Medical College & Hospital, Ambajogai 3) Govt. Medical College & Hospital, Akola

It is mandatory for the tenderers to quote in the commercial bid as mentioned below - 1) Cost of 64 Slice of detector CT Scanner with all accessories as per specifications 2) Buy back cost for the existing CT Scan in the department 3) Turn Key cost separately for above mentioned 2 institutes 4) The Price of films required for dry camera 5) CMC cost inclusive of CT Tube for seven years post warranty period. 6) CMC cost exclusive of CT Tube for seven years post warranty period. 7) Price of the CT Tube should be quoted separately. These prices will be freezed for seven years Note :- GMC, Akola needs only 64 Slice CT Scanner on buy back basis without Turnkey (No need to quote turnkey cost for GMC, Akola) A complete multislice helical CT scanner with all necessary software & hardware required to perform various clinical protocols. It should be DICOM ready with capability of transferring images to the hospital PACS, all cost born by company. The software upgrades or system improvement must be provided during warranty period and CMC. The vendor should indicate & include recent any technological advances that arent mentioned here but are appropriate for the system. Describe all work in progress. Detector Detector should acquire 64 slice in one rotation It should have 64 rows of detectors Please specify the number of elements in each row. Mention the Z axis coverage. The scan length available should at least be 40cm. Indicate the maximum reference scan length. Cone beam correction should be present Solid state detectors. Spiral Acquisition a) Scan time should be 0.4 sec. or less, for full 360 deg. rotation. b) Specify time in minutes for warm up from fully off in normal as well as emergency. c) Minimum slice thickness 0.625 mm. or less. Specify minimum slice thickness in axial, spiral and cardiac modes. d) Specify the pitch factor for general radiological application. For cardiac scanning pitch should be 0.2 or less

Page 2: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

e) Single continuous spiral scan time should be at least 50 sec. or more. f) Bolus triggered or bolus chase spiral acquisition should be available. Contrast Resolution : a) High contrast spatial resolution : Minimum of 15 or more 1p/cm at minimum MTF is essential. b) Low contrast resolution : The low contrast resolution at 20 cm CATPHAN phantom should be 5mm @ 3 H.U. Gantry Gantry aperture should be 70 cm or more Gantry tilt of +/- 30 degree. Scan FOV of 50 cm or more. Specify minimum and maximum FOV with increment value. integrated ECG, remote control of gantry should be possible. 3D laser lights for accurate centering. Specify focus to iso centre distance and focus to detector distance. Patient table Mention loading capacity : higher will be preferred. Faster horizontal table speed. Indicate couch length .Table top must be 2000 mm .Mention the metal free scannable area. Indicate weight limit & Maximum weight capacity. Carbon fibre table top. Positioning facilities for horizontal isocentre should be present. Freely selectable pitch needed. Slice thickness should be minimum of 0.625cm Mention slices thickness range on spiral mode or axial mode. Horizontal movement range and it should be sufficient to cover the patient from head to toe. Tube specification. The tube should have a history of low tube failure rate. Tube should have ability to handle high patient through put & handle rapid volume acquisitions consecutively. Indicate maximum mA allowed . Indicate the Kvp range mention heat storage capacity ( 8MHU) mention heat dissipation rate of anode ( 1600KHU/mm) radiation does modulation & optimization should be provided. Mention the small and large focal spot size. Generator High frequency generator A Minimum output of 60 KW at max current of 500mA more. if the vendor has a model with higher generator capacity , in the 64-64 type, the one with higher capacity should be quoted . Mention kv selections. mA range should be mentioned. Operator console Should have a LCD medical grade monitor of high resolute. 21" inch size display matrix of 1024 x 1024 , better is preferred Should allow scanning and processing simultaneously -dual, monitor console User friendly

Page 3: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

menu driver functions. all function of the image reconstruction, documentation , archiving , transfer, mip, volume rendering and all the various application should be present on the operating console and two separate work stations simultaneously and independently. performing scan of next sequence should start prior to complete reconstruction of previous scan. Should be DICOM compatible One console and two separate workstations with replication of the soft functions and post processing software's from the console duplicated on the workstations should be provided. Minimum number of uncompressed image in 512 x512 images : 5 lac images or more on main console and 5 lac on more or additional workstation. Radiation and specification and image quality indicate the maximum image resolution mention the display matrix - higher available should be quoted mention the reconstruction matrix - higher available should be quoted Indicate low contrast resolution in % at various scan time ; scan thickness and tune voltage, ma Indicate special resolution at various scan time and scan thickness at available kV and ma. Indicate the noise standard deviation Indicate radiation dose in mSv for routine head and body scan and during coronary CT. Dose optimization software should be provided. Describe in detail the method and the maximum amount of does reduction that canbe advised tabulated for various possible studies. ECG gated dose modulation to reduce dose during undesired cardiac phase Dose display like CDTI, volume, dose efficiency should be possible dynamic tube current modulation and automatic optimized tube current selection for minimizing dose should be provided. Algorithm for dose reduction during cardiac scanning will be an essential requirement. Paediatric and infant based protocols. Work station System should include two multimodality diagnostic reporting work stations , all the function of data processing, filming , archiving, mip and mpr, volume rendering and various software's, coronary processing should be available on both the operating console and the work station, independently and simultaneously. all functions which are possible on the console should be duplicated on both the work stations High transfer rate DICOM connectivity from main console to additional workstation. All workstation software upgrades should be available during period of warranty and CMC They should have 21 inch LCD monitors with high resolution matrix (mention matrix size) Computer and image processor - 65 bit main CPU should be 2GHZ ram or better Pentium i 7 CPU with 1tb hard disc mention image storage capacity at 512 matrix, 4lac images minimum, higher is needed. CD/DVD archival should be possible mention image reconstruction time, faster will be preferred for all types of acquisition modes with a standard 512 matrix. Should be DICOM compatible Minimum number of uncompressed image in 512 x 512 images : 5 lac images or more

Page 4: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

on main console and 5 lac or more on additional workstation Networking and dicom capability Dicom 3.0 capability or higher vesion System should be capable of interfacing with the HIS/RIS system of the status vendor should provide DICOM conformance statement All costs associated with connecting system with HIS/RIS will be vendor's responsibility ( interfacing licenses software and hardware)-pacs interface ready. The system should provide remote diagnostic capabilities via internet access. The internet access should be provided by the vendor during the period of warranty and CMC the remote diagnostic capabilities should allow to remotely connect to the system on regular basis to retrieve information and allow service support through the operator console PACS interface ready system. Clinical application Contrast media tracking CT angiography /venography whole body with quantitative vessel analysis advanced 3d analysis virtual endoscopy software dynamic cerebral perfusion mapping along with angiography at single injection. Neuro perfusion /Evaluation with Neuro perfusion analysis over large area of 80 mm or more in one examination. Routine body scan and body perfusion CT Bone densitometry dental / mandible software MIP,MPR Oncology Package including computer assisted detection: a) Auto CAD software for lung nodule evaluation. b) automated evaluation of liver. Volume rendering techniques in all modes virtual colonoscopy ,SSD MIP slab Cardiac imaging 1 calculi/m scoring 2. coronary tree extractions 3. High image reconstruction software 4. prospective ECG gating 5 . Easy volume reading of the heart 6. one click coronary angio 7.Functional analysis in long and short axis of heart Indicate the time and steps to run entire protocol - acquisition to post processing to archiving Image Evaluation and display Inaddition to the software for all routine functions like measurements, annotations, windowing, image addition and subtraction, artefact reduction capability, reversal of images, filters, reference scale and grid, the following software should also be available: a) Real time MPR ( curved /Oblique/coronal/sagital). b)Dynamic scanning and cine display specify the frame and number of images that can

Page 5: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

be displayed. c) 3D shared surface display. d)advanced 3D volume rendering technique. e) C.T. Angiography with coloured facility: MIP MPR, SSD, VR f)3D Virtual endoscopy (CT endoscopy, bronchoscopy, colonoscopy, colonography and angioscopy) g)Automatic bone sulpting. h) Advanced vessel analysis including stenosis quantification Upgradability All software upgrade on the system console workstation on the existing applications must be provided by vendor indefinitely at no cost. This will include any hardware or parts if the software added needs them to enhance the existing capabilities . New software shall be made available to the purchaser at 70% of discounted cost of the cost of the actual listed price for a period of the CMC and warranty free trial software should be enlisted and provided at the users request. Accessories : A list of accessories should be provided separately. All patient positioning accessories should be included Dual head pressure injector with 500 syringes and 1000 y tubings UPS for entire ct system with 30 minute backup. this should also include the workstation and console, at least of 120 KVPS. Dry camera ( Laser /thermal ) of 500 dpi which can print 14 & film size with digital interface. 1. Resolution - 16 bits/500 dpi 2. supports multiple film size -14"x 17" is must 3.Throughput of 100 films or more per hour 4. DICOM compatible. 5.Company should connect the machine with existing cameras in the department for alternate recording. 6. Company should supply 2000 films of -14"x 17" size for the supplied camera for testing and initial use. A. colour ink jet printer for printing images of the coronary scan which allows low cost printing . Anesthesia equipments ; - These equipments should allow anesthesia to adults and pediatric patients and should have all the necessary attachments for the same. These may be certified and verified by the concerned expert. 2 high end class 1 Boyle's apparatus (anesthesia delivery system with a multiparameter monitor equivalent CE /ISO /US-FDA certified system.) A state of art general anesthesia induction equipment with vaporizer capable of co2 monitoring with a pediatric and adult ventilator and monitors. Facility for non invasive monitoring of oxygen saturation blood pressure, respiratory rate and skin temperature during acquisition should be provided for both adult and pediatric patients. External cardiac rhythm monitor cum defibrillator with capability for synchronized biphasic shock from 5-150 joules. the device should have adult and pediatric pedals and also connectivity to patch defibrillation electrode. it should reach full charge in less than 6 seconds. it should also have external pacemaker facility. 02 line to gantry room. waiting room and the recovery area.

Page 6: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

A high quality DLP p projector 3000 ANSI Lumens and digital zoom facilities for teaching and presentations related to CT images. the projector should have wireless wifi data transmission and USB ports. Voltage stabilizer for the complete system -1 no. UPS for digital part of the system 1 no. Lead glass of approx 100 * 120 cms size 1 no. 3 good quality zero lead wrap around radiation protection apron- 5nos. Pentium i 7 processor based pcs with following specification - two 3 gb necc ddr2800mhz sdram memory 500gb sata 3.0 gb/s hard drive with native command queuing 2*1 tbb sata 3.0 gb/s hard drive with native command queuing. 19 'LCD Monitor with integrated speaker integrated intel graphics media accelrator * 4500hd windows 7 professional version. dvd rw drives optical mouse and standard keyboard two inkjet printers with low maintenance and low cost consumption qc phantoms CATPHAN should be included water phantom should be included intercom for communication between patient and system operator two iv stands two led apron stands a weighing scale a room thermometer one stretcher and one wheel chair to move patients indicator lamp at the door Miscellaneous Radiation Safety : Company should observe all the norms laid down by A.E.R.B, during supply and installation, which include certification of the whole system and permission for installation. Warranty for five (5) Years The cabling from the transformer to the site of installment should be provided by the company. CMC :- Should include the machine and its accessories, the tube and detectors, other components of the machine, UPS, computers printers, air conditioner,s pressure injectors and anesthesia equipment supplied along with the machine. Maintenance of the dry camera, computers, printers, cartridge or ink supplies, antivirus software and their up gradation and the setting up and maintenances of internet connection should also be included in the CMC. The prices of films used in the dry camera (Which are proprietary items) for all the present and future models of the supplying companies should be quoted in the price bid. These prices will be fixed and freezed for the next five years. The companies will also be bound to supply these films uninterrupted at least for the 5 years period after supply of machine or till the period the prices are freezed. The DATA sheet for the specifications in original or a certified copy of the same by the appropriate company authority should be provided. Rate for the CMC for next 8 years to be fixed at the purchase.

Page 7: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

Training The application specialist of the company should be available on site at intermittent intervals till the radiographers and the radiologists are fully trained with all applications. Training for two radiologist and two technicians at reputed institute for 15 days should be arranged. Operator manuals and technical manuals, guide books etc should be provided. Rodent control Company should take all precautions to strengthen the present construction and a fill up all the holes to prevent rodent entry in gantry and console room. Air conditioning and turnkey details should be taken from the end user. The company shall provide names, addressees, phone numbers of all the personal needed for trouble shooting of the machine, the accessories including computers antivirus software and anesthesia equipments and air conditioners and all the items covered under the warranty and CMC. The hierarchical contact list for each of these may be provided in case a call is not attended to and higher authorities need be contacted for the same.

Page 8: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

Turn Key Project Shri Vasant Rao Naik Govt. medical College, Yeotmal

The Area to be done is approximately 2000 square feel. The turnkey should include the following. (I) CIVIL WORKS 1. Providing & fixing 300 x 300 x 11.5mm thick polished vetrified tiles,

Manufactured by M/s. H.R. Johnson or equivalent make, for flooring over 40mm thick cement mortar 1:4 with to proper line level filling with white cement, curing, & cleaning, complete. Costs would include cutting from random sizes.

2. Providing & fixing 52 mm thick cement concrete flooring in Electrical room. 3. Providing & laying Dado upto 7' ht false ceiling ht using 600 x600 polished

vetrified tiles, Manufactured by H.R. Johnson or equivalent make of approved shade complete.

4. Providing & Fixing 6" black granite sill 15mm thick. on windows with 4" kota

stone in step form as per detail with cement bedding, to proper line and level etc. Costs to include necessary moulding pata, edges polished with tin oxide, complete.

5. Providing & Fixing 300 x 300 H.R. Johnson Make ceramic Tiles of approved

shade complete in toilet. For floor 6. Providing & Laying Dado in the toilet up to 7" using 8 " x 12" H .R. Johnson

Make ceramic Tiles of approved shade complete 7. Laying Plaster of Paris on flooring to give adequate protection to the Flooring and

finally removing the same. Including cleaning and washing the flooring with acid. 8. Making R.C.C. Loft on toilet area. 9. Floor trench of size 500 mm x 250 mm with open able trench covers made form

plywood. 10. P &F MS safety grill for all windows. Including one coat of red oxide paint and 2

coats of oil paint. 11. Providing & Fixing 2mm thick PVC Vinyl Flooring Including leveling the existing

damage flooring it required. (Electrical Rooms) 12. Providing and fixing carpet over flooring. FALSE CEILING 1. Providing & fixing Armstrong metal ceiling system ( non perforated ) with 0.5 mm

thick standard metal, clip in tiles 600 x 600 to be suspended from slab with 4 mm GI wire.

2. Providing opening in false ceiling with framing for tube light fitting as per size.

Page 9: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

3. Packing above false ceiling with Gypsum sheet. 4. Under deck insulation with 25 mm thick (TF quality) thremocol stuck with

adhesives below the ceiling slab .Area includes CT area. (II) CARPENTRY WORKS 1 Providing & Fixing reception table in Reporting room with single drawers in

Marine ply , laminated finish, edge moulding in hand polish, complete. Size : 10' -3" X 2'-0" x 2'-6 "ht.

2 Providing & fixing work reception table in Reporting room with single drawers in

Marine ply, Laminated finish, edge moulding in hand polish, complete. a) Size 5'-0" x 2'0" x 2'6" b) Size 4'-0" x 2'0 x 2'6"

3 Providing and making Heavy gauged aluminum doors with novopan board panel of approved shade, above and below lock Rail including door closers. standard fitting & accessories complete. including aluminum door frame.

a) Size 6'-0" x 7'-0" ht ( double leaf door with floor spring)

4 Providing & Fixing door frame with 2½ " x 5" c.p. Teak wood, complete, with 2mm lead sheet for door of CT examination

5 Providing & fixing single shutter Marine flush door with 2 mm lead sandwiched,

laminated on both sides for examination room. a) Size : 5' - 0" x 7' - 0" ht (double shutter door) b) Size : 3' - 0" x 7"- 0" ht

6 Providing and fixing 5 mm lead sheet sandwiched with laminated on both sides

in gantry room wall for 7 feet height on all inner walls.

7 Providing and fixing 5mm lead sheet sandwiched with laminated on both sides in gantry room wall for 7 feet height on all inner walls.

8 Providing & fixing door frame with 2½ " x 5" c.p. Teak wood, complete.

9 Providing & fixing single shutter Marine flush door with two colour laminate on

both sides including door closer, hinges, handle , lock & accessories opening for the vision at 5'level in glass.

a) Size 3'-0 x 7'-0"ht ( 900 mm clear door) b) Size 6'0 x 7'-0 " ht ( double shutter door)

10 Providing & fixing fiber reinforced door for toilet cost including door frame. (Size 2'-6 x 7'-0 " ht)

11 Providing & Fixing Heavy gauged anodised aluminum windows with 4 .5 mm thick plain glass including the window frame in toilets to provide louvered frosted glass after leveling the window sil.

12 Providing chairs in reporting, doctor room & Reception area.

13 Providing & Fixing Corner table 14 Computer table 3 ( Three) IN Number 4' -6" x 2'-0" x 2' 6" ht. with laminated

Page 10: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

finish.

15 Providing & Fixing powder coated metal perforated chair in reception area. ( Continuous sitting)

a) Two seater 2 ( Two) In Number b) Two seater 2 ( Two) In Number 16 Providing & fixing table in Console room with single drawers in Marine Ply,

Laminated finish, edge moulding in hand polish , complete. a) Size 6'-0" x 2'-6 " x 2'-6".

17 Providing & fixing table and side table in consultant room with three drawers unit in Marine ply, laminated finish, edge moulding in hand polish, complete. Including side credenza (3' x 1'-3" x 2'x6") a)Size 5' x 2'-6" x 2'-6"

18 Providing & fixing trap door with wooden frame supported from ceiling & 12mm

thk Marine ply shutter with paint finish for air conditioning unit. ( Size: 6'-0"x5'-0")

19 P & F cover moulding 11/2" x 3/4" to door frame to flush door both inside and

out side to flush with tiling.

20 P & F Mirror including frame and Backing support

21 P & F Soap Dispenser

22 P & F Chromium plated Towel Rod - Small size.

23 Providing & fixing Shoe Racks as per design. Size 2'-9" x 2'-9 " x 1'-3" ht.

(III) Electrical 1 Providing & fixing Primary Light point wiring with 1.5 sqmm copper wire in pvc

conduits

2. Providing & Fixing secondary light point wiring with 1.5 sqmm copper wire in pvc conduits

3. Providing & fixing 6/16 Amp. Plug & switch with 4 .00 sqmm copper wire.

4. Providing & Fixing 6 Am. Plug & switch with 2.5 sqmm copper wire.

5. P & F of Telephone RJ 11 ( D) telephone jack.

6. Providing & termination of CAT 6 Information socket with face plate & box

7. Providing & Fixing 50 A /415 V TPN MCB, 10KA 'C' series with sheet metal enclosure ( MDS MAKE)

8. Providing & fixing 63 A/415 V TPN MCB 10KA 'C' series with sheet metal enclosure( MDS MAKE)

Page 11: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

Circuits 1. Providing & Fixing of Lighting / Raw Power Circuits with 2 nos x 2.5 sqmm . + 1

no x 1.5 sqmm pvc insulated copper wire.

2. Providing & Fixing of power Circuits with 2 nos x 4 sqmm + 1no x 2.5 sqmm pvc insulated copper wire for power plug.

3. Providing & Fixing Deltron make 4 pair 0.51mm size telephone cable

4. providing & Fixing D link make CAT 6, 4 pair UTP cable including 1000mtrs cable as per tender.

5. Supplying & Instilling of Earth station with 600 x 600 x 3mm thk copper

earthing plate with charcoal, salt , watering pipe, funel, CI cover for chamber.

6. 25x 3mm copper earth patti from pit to meter panel.

7. UPS connection with 2 nos x 16 sqmm + 1no x 6 sqmm copper wire ( maximum length = 20rft.)

8. Supplying and fixing 4C x 6 sqmm copper cable from mains panel to AC indoor

unit main switch.

9. P & F of Earthing wire 1 no. x 8 gauge for AC indoor unit

10. S & F 18 SWG GI perforated cable trays 300 x 50 mm along with anchor fastener, hadware , GI support for cable trays and coupler.

11. Providing & Fixing or 2 nos x 8 SWG bare copper wire along with above cabel for

earthing

12. Networking Hardware ( details of net working : 3nos. CISCO 24 port switches( for a 1GBPS network).

Lighting Fixtures:

1. Providing & Fixing Philips / equivalent make mirror optic fitting for modular ceiling ( TBS 088 /418-C5 HPF 4 x 18 )

2. Providing & fixing Philips Make minolta 4'0" ,1 X 36,TMC,501 HF tube fitting.

3. Providing & Fixing Philips make minolta 2'0" tube fitting

4. Providing& Fixing 9" exhaust fan., Unique OR Bajaj make

5. Providing & Fixing Red colour warning light above CT room main door.

C.T. PANAL , A.C. LDB & PDB ( FOR C.T. EXAMI. . & BALANCE AREA) MAIN INCOMER 400 A TP + N MCCB , 36 KA,MDS MAKE 500A Tinned Copper Busbars T.P.N with chamber Digital Ammeter with 4 nos CT, 400 /5A Digital Voltmeter with 0-500 V, rating

Page 12: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

RYB Indicator ( LED type) with 4 A fuse Out Going 1. C.T. machine / UPS 125A TP +N MCCB, 36 KA - 1 no 2. For Lighting and power DB which consist of following. 80A /415 V, 4 pole MCB - 1 no, 10 KA, as incommer for Lighting & Power 40A /

230V, DP, 100MA, ELCB - 3 nos for lighting SP MCB - 10 A - 6 nos, 16 A- 3nos, 20 A- 3 nos, 25A-6 nos ( total 15 MCB) 40 A /415 V TPN MCB - 1no ( Spare)

Earthing link, neutral Link , Base frame complete with interconnection 3. AIR CONDITIONAL PANEL CONSIST OF 63A / 415 V , MANUAL CHANGE OVER SWITCH 4POLE - 2 NOS 63 A/ 415 V TPN MCB - 1nos ( Spare) 63A/100MA ELCB - 1 no ( Spare) 4. APFC MAIN SWITCH PROVISON 200 A/ 415 V TP MCCB for power factor panel - 1no for capacitor capacity euqal

to 100 KVA FABRICATION, PAINTING and WIRING CHARGES Panel shall be made from 16/18 SWG CRCS sheet with 3 tank process, power

coated with Siemens grey colour, Indicator lamp, 500A copper bus bar + earthing copper bar . Floor mounted with all name plate for all outgoing, proper interlocking arrangement shall be provided.

NOTE : PLEASE SUBMIT SLD and PANEL LAYOUT BEFORE EXECUTION (IV) PLUMBING WORKS

1 Supplying & fixing bib tap & pillar tap.

2. Supplying & Fixing angle cocks.

3. Supplying & fixing wall hung wash basin . ( small)

4. Supplying & Fixing jet spray

5. Supplying & Fixing wall hung W.C. of Parryware or equivalent make

6. Supplying & Fixing plastic flush tank for w.c of commander or equivalent make

7. Internal plumbing, including drainage & waste water pipes for wash basin & sink, including water supply connection from overhead tank to toilets and pantry as per layout. Including making gully trap. Note : Toilet flush water connection is Bore water while sink, Basin &Shower connection is municipal water.

8. 500 litres Sintex Overhead tank

Note

Page 13: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

1. External drainage is not part of the scope, Assumed drainage will be given upto our gullyy trap.

2. Water supply pipe line will be given upto out inlet.

MISCELLANEOUS 1 Providing & fixing inauguration plaque Size : 4' X 3' 2. Providing & fixing CT indicator light fitting made from acrylic 3. Providing & fixing room signage 4. Providing & fixing 4 " vertical blinds AIR CONDITIONERS : 1. The Whole area has to centrally air conditioned. 2. Additional 1.5 tone spilt Air conditioners 4 ( Four) in number in gantry room and

2 ( two) in console room. Note :- The vendor should visit the site personally and after inspection of

site, Price should be quoted

Page 14: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the
Page 15: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

Turn Key Project ( S. R. T. R. Govt. medical College, Ambajogai)

The Area to be done is approximately 2000 square feel. The turnkey should include the following. (I) CIVIL WORKS 1. Providing & fixing 300 x 300 x 11.5mm thk polished vetrified tiles,

Manufactured by M/s. H.R. Johnson or equivalent make, for flooring over 40mm thick cement mortar 1:4 with to proper line level filling with white cement, curing, & cleaning, complete. Costs would include cutting from random sizes.

2. Providing & fixing 52 mm thick cement concrete flooring in Electrical room.

3. Providing & laying Dado upto 7' ht false ceiling ht using 600 x600 polished vetrified tiles , Manufactured by H.R. Johnson or equivalent make of approved shade complete .

4. Providing & Fixing 6" black granite sill 15mm thick.on windows with 4" kota

stone in step form as per detail with cement bedding, to proper line and level etc. Costs to include necessary moulding pata, edges polished with tin oxide, complete.

5. Providing & Fixing 300 x 300 H.R. Johnson Make ceramic Tiles of approved

shade complete in toilet. For floor

6. Providing & Laying Dado in the toilet up to 7' using 8 " x 12" H .R. Johnson Make ceramic Tiles of approved shade complete

7. Laying Plaster of Paris on flooring to give adequate protection to the Flooring

and finally removing the same . Including cleaning and washing the flooring with acid.

8. Making R.C.C. Loft on toilet area.

9. Floor trench of size 500 mm x 250 mm with open able trench covers made

form plywood.

10. P &F MS safety grill for all windows. Including one coat of red oxide paint and 2 coats of oil paint.

11. Providing & Fixing 2mm thick PVC Vinyl Flooring Including leveling the

existing damage flooring if required. (Electrical Rooms) FALSE CEILING

1. Providing & fixing Armstrong metal ceiling system ( non perforated ) with 0.5 mm thick standard metal, clip in tiles 600 x 600 to be suspended from slab with 4 mm GI wire.

2. Providing opening in false ceiling with framing for tube light fitting as per

size.

Page 16: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

3. Packing above false ceiling with Gypsum sheet.

4. Under deck insulation with 25mm thick (TF quality ) thremocol stuck with adhesives below the ceiling slab .Area includes CT area.

(II) CARPENTRY WORKS 1. Providing & Fixing Reception table with single drawers in Marine ply ,

laminated finish, edge moulding in hand polish, complete. Size : 10' -3" X 2'-0" x 2'-6Ht.

2. Providing & fixing work table in reporting roomwith single drawers in marine

ply, Laminated finish, edge moulding in hand polish complete. a) Size 5'0 x 2'0 x 2'6" b) Size 4'0 x 2'0 x 2'6"

3. Providing and making Heavy gauged aluminum doors with novopan board panel of approved shade, above and below lock Rail including door closers. standard fitting & accessories complete. including aluminum door frame.

a) Size 6'-0" x 2'0 x 7'-0" ht ( double leaf door with floor spring)

4. Providing & Fixing door frame with 2½ " x 5" c.p. Teak wood, complete, with 2mm lead sheet for door of CT examination

5. Providing & fixing single shutter Marine flush door with 2 mm lead

sanwiched, laminated on both sides for examination room. a) Size 5'-0" x 7'-0"ht ( double shutter door) b) Size 3'-0 x 7'-0"ht

6. Providing and fixing wooden frame with 2½ " x 3" c.p. Teak 2mm lead

sheet in console room and fixing 1.0 meter x 1.5 meter lead galss ( Provide by philips)

7. Providing & fixing door frame with 2½ " x 5" c.p. Teak wood, complete.

8. Providing & fixing single shutter Marine flush door with two colour laminate on both sides including door closer, hinges, handle , lock & accessories opening for the vision at 5'level in glass.

a) Size 3'-0" x 7'-0"ht ( 900 mm clear door) b) Size 6'-0' x 7'-0 "ht ( double shutter door)

9. Providing & fixing fiber reinforced door for toilet cost including door frame. Size 2'-6" x 7'-0 " ht

10. Providing & Fixing Heavy gauged anodised aluminum windows with 4 .5 mm th plain glass including the window frame in toilets to provide louvered frosted glass after leveling the window sil.

11. Providing chairs in reporting, doctor room & Reception area.

12. Providing & Fixing Corner table

13. Computer table 3 ( Three) IN Number 4' -6" x 2'-0" x 2' 6" ht. with laminated

Page 17: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

finish.

14. Providing & Fixing powder coated metal perforated chair in reception area. ( Continuous sitting)

a) Two seater 15. Providing & fixing table in Console room with single drawers in Marine Ply,

Laminated finish, edge moulding in hand polish , complete. a) Size 6'-0" x 2'-6 " x 2'-6".

16. Providing & fixing table and side tabel in consultant room with three drawers unit in Marine ply, laminated finish, edge moulding in hand polish, complete. Including side credenza (3' x 1'3" x 2'x6") a)Size 5' x 2'-6" x 2'-6"

17. Providing & fixing trap door with wooden frame supported from ceiling &

12mm thk Marine ply shutter with paint finish for air conditioning unit. ( Size: 6'-0"x5'-0")

18. P & F cover moulding 11/2" x 3/4" to door frame to flush door both inside

and out side to flush with tiling.

19. P & F Mirror including frame and Backing support

20. P & F Soap Dispenser

21. P & F Chromium plated Towel; Rod - Small size.

22. Providing & fixing Shoe Racks as per design. Size 2'-9" x 2'-9 " x 1'-3" ht. Electrical

1 Providing & fixing Primary Light point wiring with 1.5 sqmm copper wire in pvc conduits

2. Providing & Fixing secondary light point wiring with 1.5 sqmm copper wire

in pvc conduits

3. Providing & fixing 6/16 Amp. Plug & switch with 4 .00 sqmm copper wire.

4. Providing & Fixing 6 Am. Plug & switch with 2.5 sqmm copper wire.

5. P & F of Telephone RJ 11 ( D) telephone jack.

6. Providing & termination of CAT 6 Information socket with face plate & box

7. Providing & Fixing 50 A /415 V TPN MCB, 10KA 'C' series with sheet metal enclosure ( MDS MAKE)

8. Providing & fixing 63 A/415 V TPN MCB 10KA 'C' series with sheet metal enclosure ( MDS MAKE)

Page 18: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

Circuits

1. Providing & Fixing of Lighting / Raw Power Circuits with 2 nos x 2.5 sqmm . + 1 no x 1.5 sqmm pvc insulated copper wire.

2. Providing & Fixing of power Circuits with 2 nos x 4 sqmm + 1no x 2.5 sqmm

pvc insulated copper wire for power plug.

3. Providing & Fixing Deltron make 4 pair 0.51mm size telephone cable

4. providing & Fixing D link make CAT 6, 4 pair UTP cable including 1000mtrs cable as per tender.

5. Supplying & Instilling of Earth station with 600 x 600 x 3mm thk copper

earthing plate with charcoal, salt , watering pipe, funel, CI cover for chamber.

6. 25x 3mm copper earth patti from pit to meter panel.

7. UPS connection with 2 nos x 16 sqmm + 1no x 6 sqmm copper wire ( maximum length = 20rft.)

8. Supplying & fixing 4C x 6 sqmm copper cable from mains panel to AC

indoor unit main switch. 9. P & F of Earthing wire 1 no. x 8 gauge for AC indoor unit

10. S & F 18 SWG GI perforated cable trays 300 x 50 mm along with anchor fastener, hadware , GI support for cable trays and coupler.

11. Providing & Fixing or 2 nos x 8 SWG bare copper wire along with above cabel

for earthing

12. Networking Hardware ( details of net working : 3nos. Cisco 24 port switches( for a 1GBPS network).

Lighting Fixtures:

1. Providing & Fixing Philips / equivalent make mirror optic fitting for modular ceiling ( TBS 088 /418-C5 HPF 4 x 18 PHILIPS)

2. Providing & fixing Philips Make minolta 4'0" ,1 X 36,TMC,501 HF tube fitting.

3. Providing & Fixing Philips make minolta 2'0" tube fitting

4. Providing& Fixing 9" exhaust fan., Unique OR Bajaj make

5. Providing & Fixing Red colour warning light above CT room main door. C.T. PANAL , A.C. < LDB & PDB ( FOR C.T. EXAMI. . & BALANCE AREA) MAIN INCOMER

Page 19: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

400 A TP + N MCCB , 36 KA,MDS MAKE 500A Tinned Copper Busbars T.P.N with chamber Digital Ammeter with 4 nos CT, 400 /5A Digital Voltmeter with 0-500 V, rating RYB Indicator ( LED type) with 4 A fuse Out Going 1. C.T. machine / UPS 125A TP +N MCCB, 36 KA - 1no

2. For Lighting and power DB which consist of following.

80A /415 V, 4 pole MCB - 1 no, 10 KA, as incommer for Lighting & Power 40A / 230V, DP, 100MA, ELCB - 3 nos for lighting SP MCB - 10 A - 6 nos, 16 A- 3nos, 20 A- 3 nos, 25A-6 nos ( total 15 MCB) 40 A /415 V TPN MCB - 1no ( Spare)

Earthing link, neutral Link , Base frame complete with interconnection 3. AIR CONDITIONAL PANEL CONSIST OF 63A / 415 V , MANUAL CHANGE OVER SWITCH 4POLE - 2

NOS 63 A/ 415 V TPN MCB - 1nos ( Spare) 63A/100MA ELCB - 1 no ( Spare)

4. APFC MAIN SWITCH PROVISON 200 A/ 415 V TP MCCB for power factor panel - 1no for capacitor capacity

euqal to 100 KVA

FABRICATION, PAINTING & WIRING CHARGES Panel shall be made from 16/18 SWG CRCS sheet with 3 tank process,

power coated with Siemens grey colour, Indicator lamp, 500A copper bus bar + earthing copper bar . Floor mounted with all name plate for all outgoing, proper interlocking arrangement shall be provided.

NOTE : PLEASE SUBMIT SLD & PANEL LAYOUT BEFORE EXECUTION) (IV) PLUMBING WORKS

1 Supplying & fixing bib tap & pillar tap.

2. Supplying & Fixing angle cocks.

3. Supplying & fixing wall hung wash basin . ( small)

4. Supplying & Fixing jet spray

5. Supplying & Fixing wall hung W.C. of Parryware or equivalent make

6. Supplying & Fixing plastic flush tank for W.C. of commander or equivalent make

7. Internal plumbing, including drainage & waste water pipes for wash basin &

sink, including water supply connection from overhead tank to toilets and pantry as per

Page 20: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the

layout. Including making gully trap. Note : Toilet flush water connection is Bore water while sink, Basin &Shower connection is municipal water.

8. 500 litres Sintex Overhead tank

Note 1 External drainage is not part of the scope, Assumed drainage will be given

upto our gully trap. 2. Water supply pipe line will be given upto out inlet. MISCELLANEOUS

1 Providing & fixing inauguration plaque Size : 4' X 3' 2. Providing & fixing CT indicator light fitting made from acrylic 3. Providing & fixing room signage 4. Providing & fixing 4 " vertical blinds AIR CONDITIONERS :

1. The Whole area has to centrally air conditioned. Note :- The vendor should visit the site personally and after inspection

of site, Price should be quoted

Page 21: 64 Slice CT Scanner for all purpose scanning including ... Slice CT Scanner for all purpose scanning including coronary Angiography. ... (CT endoscopy, bronchoscopy ... cost of the