Explosion-proof Standard
Model Name Options
EXN22-AFBD(PP)EXN60-AFBD(PP)EXN80-AFBD(PP)
Ex ‘d’ *1 Flame-proof
Ⅱ *2 For factories and industrial buildings
B+H2 *3 Group B including H2
T6 *4 Temperature grade below 95℃
*1 While the methods of protection from explosion are various, the certificates of explosion-proof lamps include the flame-proof enclosure, increased-safety explosion-proof certificate, and non-incendive explosion-proofing. Among these methods of protection, "Flame-proof Enclosure" is an international term describing an enclosure that can withstand the pressure developed during an internal explosion of an explosive mixture and that prevents the transmission of the explosion to the explosive atmosphere surrounding the enclosure and that operates at such an external temperature that a surrounding explosive gas or vapor will not be ignited thereby. This enclosure is most durable and similar to an explosion-proof enclosure. This type of protection is referred to by IEC as “Ex ‘d’”. These LED lamps are certified with the flame-proof enclosure.
* 2 Classification terms designating dangerous locations differ by countries. The term "Zone" is used in Europe (CENELEC and IEC), while the term "Division" is used in the United States and Canada.
"Zone" or "Division" is the international method of specifying the probability that a location is made hazardous by the presence, or potential presence of flammable concentrations of gases or vapors.
・Zone 0 (Division 1) : An area in which an explosive gas-air mixture is continuously present or present for long periods. In the U.S., Zone 0 and Zone 1 are incorporated into Division 1.
・Zone 1 (Division 1) : An area in which an explosive gas-air mixture is likely to occur in normal operation. Equal to a Division 1 hazardous location in the U.S. and Canadian classifications.
・Zone 2 (Division 2) : An area in which an explosive gas-air mixture is not likely to occur and if it does occur, will only exist for a short time.
* 3 This LED lamp encompasses all the atmospheres (hazardous gases or vapors) in Group B as well as H₂ in Group C.
*4 The temperature identification number represents the maximum surface temperature of any component that may come in contact with the flammable gas or vapor mixture. Six temperature classes are allocated to the explosion-proof lamp from T1 to T6. This LED lamp was certified with the highest T6 class.
NO. PARTS NAME MATERIAL ETC.
① LENS TEMPERED GLASS ー
② BODY ALUMINUM FLUORINE COATING
③ CONVERTER CASE ー FLUORINE COATING
④ JOINT BOX ALUMINUM FLUORINE COATING
NO. PARTS NAME MATERIAL ETC.
① LENS TEMPERED GLASS ー
② BODY ALUMINUM FLUORINE COATING
③ CONVERTER CASE ー FLUORINE COATING
④ JOINT BOX ALUMINUM FLUORINE COATING
NO. PARTS NAME MATERIAL ETC.
① LENS TEMPERED GLASS ー
② BODY ALUMINUM FLUORINE COATING
③ CONVERTER CASE ー FLUORINE COATING
④ JOINT BOX ALUMINUM FLUORINE COATING
91.0
116.0
321
520
91.0116.0
①②
③
④
91.0
116.0
321
520
91.0116.0
①②
③
④
350cd
0cd
700cd
1,050cd
1,750cd
2,100cd
1,400cd
180°
0°
90°270°
-0°H-90° H
Illuminance at a DistanceCenter Beam (lx)
■ Vert. Spread: 104.1°■ Horiz. Spread: 104.0°
507.2 lx
126.8 lx
56.4 lx
31.7 lx
20.3 lx
14.1 lx
5.1m
10.3m
15.4m
20.5m
25.7m
30.8m
5.1m
10.2m
15.4m
20.5m
25.6m
30.7m
Beam Width
2.0m
4.0m
6.0m
8.0m
10.0m
12.0m
105cd
0cd
210cd
315cd
525cd
630cd
420cd
180°
0°
90°270°
-0°H-90° H
Illuminance at a DistanceCenter Beam (lx)
■ Vert. Spread: 113.6°■ Horiz. Spread: 113.6°
2,437.9 lx
609.5 lx
270.9 lx
152.4 lx
97.5 lx
67.7 lx
1.5m
3.1m
4.6m
6.1m
7.6m
9.2m
1.5m
3.1m
4.6m
6.1m
7.6m
9.2m
Beam Width
0.5m
1.0m
1.5m
2.0m
2.5m
3.0m
483cd
0cd
967cd
1,450cd
2,417cd
2,900cd
1,933cd
180°
0°
90°270°
-0°H-90° H
Illuminance at a DistanceCenter Beam (lx)
■ Vert. Spread: 100.7°■ Horiz. Spread: 101.5°
711.7 lx
177.9 lx
79.1 lx
44.5 lx
28.5 lx
19.8 lx
4.8m
9.6m
14.5m
19.3m
24.1m
28.9m
4.9m
9.8m
14.7m
19.6m
24.5m
29.4m
Beam Width
2.0m
4.0m
6.0m
8.0m
10.0m
12.0m
Model NamePower
Consumption(W)
ColorTemperature
(K)
TotalLuminous Flux
(lm)
Input(V/Hz)
CRIWeight
(kg)Certification
BeamAngle
(°)IP
EXN80-AFBDS(PP) 80 5,700 6,400 100-240 50/60 >73 8.5(Arm 0°type) IEC, IECEx, ATEX 110 65
Model NamePower
Consumption(W)
ColorTemperature
(K)
TotalLuminous Flux
(lm)
Input(V/Hz)
CRIWeight
(kg)Certification
BeamAngle
(°)IP
EXN22-AFBDS(PP) 22 5,700 1,650 100-240 50/60 >75 3.2(Arm 0°type) IEC, IECEx, ATEX 110 65
Model NamePower
Consumption(W)
ColorTemperature
(K)
TotalLuminous Flux
(lm)
Input(V/Hz)
CRIWeight
(kg)Certification
BeamAngle
(°)IP
EXN60-AFBDS(PP) 60 5,700 4,800 100-240 50/60 >75 8.3(Arm 0°type) IEC, IECEx, ATEX 110 65
unit : mm
unit : mm
SPECIFICATIONS
180
344
91.0
116.0
91.0116.0
①②
③
④
INTRODUCTION OF PRODUCTS
The EXN series LED Lamps safely replace conventional explosion-proof lamps. These LED Lamps have obtained IECEx certification, the international certification requirement for safety and explosion-proof equipment in explosive environments.
■ Components
■ Components■ Components
■ Illumination Data
■ Illumination Data■ Illumination Data
■ Drawings
■ Drawings
■ Drawings
EXN80-AFBD(PP)
EXN60-AFBD(PP)
EXN22-AFBD(PP)
EXPLOSION-PROOF LED LAMPKOWA