58784587-ZTE

22
Scope of Activities Per Site 5950 Scope 2 - BTS Implementation Per Site 4760 Scope 3 – Minilink HOP(1+0) Per Hop 1440 Scope 4 – Minilink(1+1) Per Hop 2040 1440 Scope 6 - Expansion (4,4,4 to 6,6,6) Per Site 2464 960 4760 1200 600 Scope 10 - Antenna changeover Per Site 400 Scope11-1800 SITE (Co-located with 900) MBC Per Site 2816 Scope 12 -TRU ADDITION 200 2112 3168 3872 2816 Per Hop 2816 Unit of Measurement Scope I - BTS and Minilink (1+0 ) outdoor and indoor Scope 5 - Expansion for RBS 2202 (2,2,2 to 4,4,4) Per Site (with cabinet expansion) Scope 7 - Preventive site Maintenance of Bharti-All Circles Per site (Not applicable for ASP who have separate site maintenance contract) Scope 8 – Macro-cell change out (replacing 2202 with 2206) Per Site (Including Transportation charges) Scope 9 -GSM Antenna Height Reduction (With Antenna Mounts or without Antenna Mount ) Per Site (With Antenna Mounts) Per Site (Without Antenna Mounts) Per Site (Upto 3 TRU's) Scope 13 – Micro cell Installation (2302 or 2308) Per Site (Excluding Transportation charges) Scope 14 – Microcell Installation (2*2308 or 2*2302) Per Site (Excluding Transportation charges) Scope 15 – Microcell Installation (2*2308 or 2*2302) with Minilink Per Site (Excluding Transportation charges) Scope 16 – Microcell Installation (2308 or micro BTS) with Minilink Per Site (Excluding Transportation charges) Scope 17 - Microwave hop Installation (1.8 meter & 1.2 meter), one antenna each at both ends, 1+0 0r 1+1) on backbone site.

Transcript of 58784587-ZTE

Page 1: 58784587-ZTE

Scope of Activities

Per Site 5950

Scope 2 - BTS Implementation Per Site 4760

Scope 3 – Minilink HOP(1+0) Per Hop 1440

Scope 4 – Minilink(1+1) Per Hop 2040

1440

Scope 6 - Expansion (4,4,4 to 6,6,6) Per Site 2464

960

4760

1200

600

Scope 10 - Antenna changeover Per Site 400

Scope11-1800 SITE (Co-located with 900) MBC Per Site 2816

Scope 12 -TRU ADDITION 200

Scope 13 – Micro cell Installation (2302 or 2308) 2112

3168

3872

2816

Per Hop 2816

Per Hop 3910

Per Site 2112

Unit of Measurement

Scope I - BTS and Minilink (1+0 ) outdoor and indoor

Scope 5 - Expansion for RBS 2202 (2,2,2 to 4,4,4)

Per Site (with cabinet expansion)

Scope 7 - Preventive site Maintenance of Bharti-All Circles

Per site (Not applicable for ASP who have separate site maintenance contract)

Scope 8 – Macro-cell change out (replacing 2202 with 2206)

Per Site (Including Transportation charges)

Scope 9 -GSM Antenna Height Reduction (With Antenna Mounts or without Antenna Mount )

Per Site (With Antenna Mounts)

Per Site (Without Antenna Mounts)

Per Site (Upto 3 TRU's)

Per Site (Excluding Transportation charges)

Scope 14 – Microcell Installation (2*2308 or 2*2302)

Per Site (Excluding Transportation charges)

Scope 15 – Microcell Installation (2*2308 or 2*2302) with Minilink

Per Site (Excluding Transportation charges)

Scope 16 – Microcell Installation (2308 or micro BTS) with Minilink

Per Site (Excluding Transportation charges)

Scope 17 - Microwave hop Installation (1.8 meter & 1.2 meter), one antenna each at both ends, 1+0 0r 1+1) on backbone site.

Scope 18 - Microwave hop Installation (1.8 meter & 1.2 meter), two antenna each at both ends, (1+1) on backbone site.

Scope 19 - Replacement of BTS 2202 with BTS 2206 - INDOOR

Page 2: 58784587-ZTE

Per Site 2464

Scope 21 - Alignment of Existing Hop Per Hop 720

Per Site 480

Per Site 2816

Per Feeder Cable 320

800

1232

Per Pole 360

Scope 26 - Changing of ODU Per ODU 200

Per Hop 1000

Per Hop 2288

Scope 29 - Polarization Changes Per Site 200

Scope 30 – Repeater installation & de-installation

1440

640

Scope 31 – Swaping of 2302 with 2308/2309 Per Site 1440

Per Hop 2816

Scope 33 – Dismantle of BTS includingML Per Site 2464

Scope 34 – Dismantle of ML hop (0.6m) Per Hop 880

Scope 35 – Dismantle of ML hop (1.2m) Per Hop 1440

Per Site 4420

Per Site 3740

Per Site 7820

Scope 39 – Installation of BTS (2 RBS cabinets) Per Site 7140

Per Site 2816

Per Site 3520

Per Site 3520

Per Site 4080

Per Site 2112

Scope 20 - Expansion of BTS 2206 with BTS 2202 collocated

Scope 22 - Installation of ODU,IF CABLE,MMU, Wave guide Splitters and Base Plates (for 1+1 hops)

Scope 23 – Replacement of RBS 2202 with RBS 2206 along with 2 to 3 sector addition - 2 days

Scope 24 - Replacement of Feeder Cable with connectorization and Earthing

2 to 3 Feeder Cables

4 to 6 Feeder Cables

Scope 25 - Installation/Deinstallation of MW/GSM Pole

Scope 27 - Upgradation of MW from 1+0 to 1+1 Config.

Scope 28 - Changing of Antenna from 0.3/0.6 mtr. To 1.2 mtr

Per Site (Repeator Installation)

Per Site(Repeator De-Installation)

Scope 32 – High Capacity MW installation with ECI MUX or AXX or TRAFFIC NODE

Scope 36 – Installation of outdoor BTS & ML site (RBS 2106/2104/2954)

Scope 37 - Installation of outdoor BTS only (RBS 2106/2104/2954)

Scope 38 – Installation of BTS (2 RBS cabinets)& ML hop

Scope 40 – INSTALLATION OF RBS 2111 With SMPS & Battery BankScope 41 – INSTALLATION OF RBS 2111 with Mini Link, With SMPS & Battery Bank

Scope 42 – INSTALLATION OF RBS 2111(Two cabinets) With SMPS & Battery Bank

Scope 43 – INSTALLATION OF RBS 2* 2111 with Mini Link

Scope 44 :- EXPANSION of RBS 2111 (2,2,2 to 4,4,4)

Page 3: 58784587-ZTE

Per Site 1440

Scope 46 – INSTALLATION OF AXX 9300) Per Site 2112

Per Site 1440

Per Site 4760

2464

2816

Per Site 4760

Per Site 5950

Per Site 14110

Scope 53 – Installation of OMS 16XX Nodes Per Site 3910

Per Site 10200

Per Site 11900

Scope 56 –Installation of 12xx nodes Per Site 3168

Per Site 8840

Per Site 14110

Per Site 10200

Per Site 3910

Per Site 11900

Scope 62 –Installation of MD202 Nodes Per Site 3168

Per Site 8840

9350

5100

Scope 45 – INSTALLATION OF AXX 9100 or 9200

Scope 47 – SWAP OUT OF MACRO BTS WITH 2308/2309(Micro)

Scope 48 – INSTALLATION OF BTS (With Antenna Mounts)

Scope 49 – EXPANSION FROM 2+2+2 TO 6+6+6 (Single cabinet & double cabinet)

Per Site (for Single Cabinet expansion)

Per Site (for Double Cabinet expansion)

Scope 50 – Implementation of Node B(Only) (WCDMA)

Scope 51 – Implementation of Node B with Mini Link (WCDMA)

Scope 52 – Installation, Commissioning, Integration and AT of OMS 16XX Nodes (includes test equipment for AT )

Scope 54 – Commissioning, Integration and AT of OMS 16XX Nodes (includes test equipment for AT )

Scope 55 – Installation, Commissioning, Integration and AT of OMS 12XX Nodes (includes test equipment for AT)

Scope 57 – Commissioning, Integration and AT of OMS 12XX Nodes (includes test equipment for AT)

Scope 58 – Installation, Commissioning, Integration and AT of MHL3000 (single row or dual row) Nodes(includes test equipment for AT)

Scope 59 – Commission, Integration & AT for MHL 3000 (single row or dual row) ; (includes test equipment for AT )

Scope 60 – Installation of MHL3000 Nodes (single row or dual row )

Scope 61 – Installation, Commissioning, Integration and AT of MD202 Nodes(includes test equipment for AT)

Scope 63 – Commissioning, Integration and AT of MD202 Nodes (includes test equipment for AT)

Scope 64 – Installation, Commissioning, Integration and AT of XMP1 Nodes or MHL

compact node (For Optical or Electrical testing) ; (includes test equipment for AT)

Per Site (For Optical & Electrical testing)

Per Site (For Electrical testing)

Page 4: 58784587-ZTE

Per Site 2640

6800

2640

Per Site 2816

Per Site 1440

Scope 69 – Installation of 8xx nodes Per Site 1440

Scope 70 - 2 to 3 sector expansion Per Site 1000

Scope 71 - TMA or Filter Installation Per Site 600

200

300

Scope 73 – Supply of Manpower 0

Supervisor Per Month 8800

Supervisor Per Day 360

Technician/Installation Engineer Per Month 7200

Technician/Installation Engineer Per Day 280

Testing Engineer Per Day 440

Rigger Per Month 4800

Rigger Per Day 180

Per Day 200

Per Day 280

Per Site 5100

Per Site 3910

Per Site 1620

Per Site 1800

Per Site 1980

Scope 65 – Installation of XMP1 Nodes or MHL compact node

Scope 66 – Commissioning, Integration & AT of XMP1 or MHL compact node (For Optical or

Electrical testing);(includes test equipment for AT )

Per Site (For Optical & Electrical testing)

Per Site (For Electrical testing)

Scope 67 – Installation, Commissioning, Integration and AT of OMS 8XX Nodes (includes test equipment for AT)

Scope 68 – Commissioning, Integration and AT of OMS 8XX Nodes(includes test equipment for AT )

Scope 72 - Cut-out for cable inlets (Roxtec) 7/8” or 1-1/4” or 1-5/8”

Per cable inlet ( 7/8” )

Per cable inlet (1-1/4”or1-5/8”)

Rigger Daily Allowance (Only applicable If asked to work outside of base city for Night Accomodation other living expenses other than Metro cities defined

Rigger Daily Allowance (Only applicable If asked to work outside of base city for Night Accomodation other living expenses for Delhi and NCR region, Chennai, Kolkatta, Bangalore, Pune, Hyderabad & Mumbai

Scope 74 - Implementation of BTS & ML site (GSM/WCDMA)-3 Days-Without battery bank & smps installation

Scope 75 - Implementation of BTS (GSM/WCDMA) – 2 Days-Without battery bank & SMPS installation.

Scope 76 - REPLACEMENT OF BTS 2202 WITH BTS 2206 INDOOR- (1 Day)(Without battery bank and SMPS.)

Scope 77 - EXPANSION OF BTS 2206 WITH BTS 2202 COLLOCATED - (1.5 Day) Without battery bank and SMPS

Scope 78 - Replacement of BTS 2202 with BTS 2206 - indoor and third sector addition – 2 Days-(Without battery bank and SMPS)

Page 5: 58784587-ZTE

Per Hop 1980

Per Site 1980

Per Hop 480

Per Hop 1000

Per Site 6970

Per Site 6290

Per Site 2288

Per Site 3060

Per Site 2992

Per Site 3696

Per Site 600

Per Site 1400

Per Site 1000

Per Site 3910

Per Site 3910

Per Site 5100

Per Site 4420

Per Site 3740

Per Site 7820

Scope79 - HIGH CAPACITY MW INSTALLATION WITH ECI MUX OR AXX OR TRAFFIC NODE – (2 Days)-Without battery bank and SMPS

Scope 80 - DISMANTLING OF BTS &ML – (1 Day)-Without battery bank and power plant

Scope 81 - Dismantle of ML hop (0.6m) – (0.5 Day)-Without battery bank and power plant

Scope 82 - Dismantle of ML hop (1.2m) – (0.5 Day)- Without battery bank and power plant

Scope 83 - INSTALLATION OF BTS (2 RBS CABINETS)& ML HOP - (4 Days) Without battery bank and SMPS

Scope 84 - INSTALLATION OF BTS (2 RBS CABINETS) – (3 Days) Without battery bank and SMPS

Scope 85 - INSTALLATION OF RBS 2111 – (1.5 Days)-Without battery bank and UPS

Scope 86 - INSTALLATION OF RBS 2111 with Mini Link – (2 Days) -Without battery bank and UPS

Scope 87 - INSTALLATION OF RBS 2111(Two cabinets) – (2 Days)Without battery bank and UPS

Scope 88 - INSTALLATION OF RBS 2* 2111 with Mini Link – (3 Days) Without battery bank and UPS

Scope 89 - INSTALLATION OF AXX 9100/9200 – (1 Day) Without battery bank and power plant

Scope 90 - INSTALLATION OF AXX 9300 – (1.5 Day) Without battery bank and SMPS

Scope 91- SWAP OUT OF MACRO BTS WITH 2308/2309 (Micro) – (1 Day) Without Battery Bank and SMPS

Scope 92 - INSTALLATION OF BTS (With Antenna Mounts) - (2 Days) Without battery bank and SMPS

Scope 93 - Implementation of Node B (Only) (WCDMA) – (2 Days) Without battery bank and SMPS

Scope 94 - Implementation of Node B with Mini Link (WCDMA) – (3 Days) Without battery bank and SMPS

Scope 95 - INSTALLATION OF OUTDOOR BTS 2954/ 2974 Enclosure(having one cabinet with maximum capacity of 4+4+4) with ML(1+0) – (2.5 Days)

Scope 96 - INSTALLATION OF OUTDOOR BTS 2954/2974 enclosure only(having single RBS cabinet with a maximum capacity of 4+4+4) – (1.5 Day)

Scope 97- INSTALLATION OF 2954/2974 Enclosure (having 2 BTS CABINETS) with ML HOP(1+0) - (4 Days)

Page 6: 58784587-ZTE

Per Site 7140

Per Site 3740

Per Site 3740

0

Per Site 2160

Per Site 2816

Per Site 5168

Per Site 8568

Per Site 6698

Per Site 8568

0

Per Site 2112

Per Site 2816

0

Per Site 2112

Per Site 2816

Per Site 2816

Per Site 3168

0

A) I&C done by other ASP Per Site 1000

B) I&C done by self Per Site 800

0

Scope 98 - INSTALLATION OF 2954/2974 Enclosure (having 2 BTS CABINETS) only – (3 days)

Scope 99 - Swapping of Nokia/Motorola outdoor with Ericsson 2974/2954 enclosure (having one cabinet with maximum capacity of 4+4+4

Scope 100 - Expansion in 2974 BTS enclosure from one cabinet with 4,4,4 configuration to 6,6,6/8,8,8 configuration

Scope101 - Replacement of 2202 cabinet with 444 config & Expansion upto 888 with (900+1800) RBS 2206/2964-3 days

A) REPLACEMENT OF BTS 2202 WITH BTS 2206/2964 INDOOR- (1 Day)

B) 1800 SITE (CO-located WITH 900), Multi Band CELL (MBC)–(2 Days)

Scope102 - INSTALLATION OF OUTDOOR BTS 2954/2974 Enclosure(having one cabinet with maximum capacity of 4+4+4) with ML(1+1)

Scope 103 - INSTALLATION OF OUTDOOR 2954/2974 Enclosure (having 2 BTS CABINETS) with ML HOP(1+1)

Scope 104 - Implementation of BTS & ML(1+1) site (GSM/WCDMA)-3 Days

Scope 105 - INSTALLATION OF BTS (2 RBS CABINETS)& ML HOP(1+1)

Scope 106 - Swapping of Nokia BTS cabinet with 444 config & Expansion upto 666/888 with (900+1800) RBS 2206/2964-3 days

A)      REPLACEMENT OF Nokia BTS with BTS 2206/2964 INDOOR- (1 Day)

B)      1800SITE(CO-located WITH 900),Multi Band CELL(MBC)– (2 Days)

Scope 107 - Swapping of Nortel/Nokia BTS cabinet with 444 config & Expansion upto 666/888 with (900) RBS 2206/2964

A)      REPLACEMENT OF Nortel/Nokia BTS with BTS 2206/2964 INDOOR- (1 Day)

B)      BTS Expansion (4,4,4 to 6,6,6/888) - (1.5 Days)

Scope 108 - Swapping of Nortel/Nokia BTS cabinet having config of 444 to 444 with RBS 2206/2964

Scope 109 - Swapping of Nortel/Nokia BTS (with Mini-Link De-installation cabinet having config of 444 to 444 with RBS 2206/2964

Scope 110 - Scope of work of a BTS Tester (Not to be Used)

Scope 111 - Replacement of 2202 cabinet with 444 config & Expansion upto 888 with RBS 2206/2964-(900 or 1800)

Page 7: 58784587-ZTE

Per Site 2112

Per Site 2464

Per Hop 1200

Per Hop 1000

Per Site 4420

Per Site 2816

Per Site 3520

Per Site 3590.4

Per Site 4216

Per Site 3696

Per Site 4250

Per Site 5270

Per Site 3696

Per Site 1400

Per Hop 2464

Per Hop 2816

Per Site 1600

Per Site 1920

Per Site 1200

A)      REPLACEMENT OF BTS 2202 WITH BTS 2206/2964 INDOOR- (1 Day)

B)      Expansion from 444 to 666/888

Scope 112 - PDH Hop upgrade from 4*2 TO 16*2 & 1+0 to 1+1 configuration

Scope 113 - PDH TO SDH HOP UPGRADE with 1+0 configuration

Scope 114 - Swapping of Nokia/Motorola outdoor with Ericsson 2974/2954 enclosure (having two cabinets with maximum capacity of 8+8+8)

Scope 115 - Swapping of Motorola micro cabinet with 2111 BTS

Scope 116 - Swapping of Motorola micro cabinet with 2111 BTS(double cabinet )

Scope 117 - Swapping of Motorola/Nokia BTS cabinet with one/two RBS 2964 having maximum configuration of 888

Scope 118 - Swapping of Motorola BTS cabinet with RBS 2964( Three/four cabinets)

Scope 119 - Swapping of Nortel/Nokia BTS (with Mini-Link Dismantling &new Minilink hop installation cabinet having config of 444 to 444 with RBS 2206/2964

Scope 120- Nokia/Nortel swap 444 with RBS 2974 with Minilink dismanteling, Battery bank & SMPS swap and new Ericsson MW hop installation

Scope 121 - Nokia/Nortel Swap 444 to 444 with RBS 2206/2964 + expansion upto 888 in 900+1800 (MBC) config with Minilink de-installation and new Ericsson Minilink HOP Installation

Scope 126 -Implementation of BTS (GSM/WCDMA) – 2 Days-Without battery bank, SMPS & GSM Antennas installation

Scope 127 -De-installation of BTS 2111 (1 to 2) MU and RRU's without Battery, SMPS & MW – 1 Day Unit Rate 3500/- Per Site

Scope 128 -Microwave hop Installation (1.2 meter), one antenna each at both ends, 1+0 0r 1+1) on access site.

Scope 129 -Microwave hop Installation (1.8 meter), one antenna each at both ends, 1+0 0r 1+1) on access site.

Scope 134 -BTS Integration & Acceptance Testing (H/O) to Custoemr/Ericsson (Site Installed by Self)

Scope 135 -Integration & Acceptance Testing (H/O) to Custoemr/Ericsson (Site Installed by other ASP)

Scope 136 -Acceptance Testing (H/O in case of Prvate Operators) (Site Installation and Integration done by other ASP)

Page 8: 58784587-ZTE

Per Site 1000

Scope 137 -MW Integration & Acceptance Testing (H/O) to Custoemr/Ericsson (Site Installed by Self)

Page 9: 58784587-ZTE

Sl.No Description unit Division Item unit1 Core Equipment Installation Scenario

1.1 per Rack 3400

1.2 per Rack 3400

1.3 Cable Tray Installation at Core Room per Meter 16

1.4 DDF RACK Installation per Rack 800

1.5 ODF Rack Installation per Rack 800

2 BTS Installation Scenario 0

2.1 per Site 800

2.2 per Site Site

2.3 per Site 5600

2.4 per Site 4000

2.5 per Site 2000

2.6 per Sector 720

2.7 per Sector 360

2.8 per Site 800

2.9 per Site 800

2.10 per Site 640

2.11 Grounding Testing per Site 400

2.12 BTS Expansion per Site 2800

2.13 BTS Swapping per Site 4800

2.14 GSM Antenna change over. Per Sector 720

2.15 Realignment of Existing hop Per Sector 1120

2.16 MW ODU replacement Per Rack 600

Target price 2010

Server Rack (MSC,MGW,BSC,NGN,UMS,MSG,SS1,HLRe,OMC) Installation With cabling, Routing, Connectivity & Terminations

Switch Rack (MSC,MGW,BSC,NGN,UMS,MSG,SS1,HLRe) Installation With Cabling, Routing, Alarm Box, Connectivity & Terminations

BTS Site Survey, providing Site Survey detail report along with as built drawings / Engineering Site Survey

BTS Indoor Installation, Commissioning, Integration & ATP Sign-Off

BTS indoor Installation (only Indoor installation and Cabling work, no commissioning and no AT work)

BTS Indoor +Outdoor Installation, Commissioning, Integration & ATP Sign-Off

MBTS/BBU Site Indoor Installation and RFS/RRU Tower Top Mounted (Optical cable &Power Cable Routing, No Feeder cable)

BTS Outdoor Installation (Hoisting of 3 Antennas, Connectivity & Routing of Feeder Cables)(without cable tray)

BTS Outdoor Installation (Hoisting of 1 Omni-Antenna, Connectivity & Routing of Feeder Cables)

Installation of Antenna Pole or RRU or MW Pole

VSWR&DFT Measurement at site with data recording (provided soft copy of data) ,Testing Meter Provide by Vendor

Power Calibration Only, Power Meter Provide by Vendor

RRU to BBU Optical Cable Power loss Measurement

Page 10: 58784587-ZTE

2.17 MW Hop up gradation from 1+0 to 1+1 Per Hop 1200

2.18 Per Meter 20

3 MW Scenario

3.1 per Hop 2800 Hop

3.2 per Hop 3600 Hop

Hop

3.3 per Hop 4800 Hop

4 Power Equipment Scenario

4.1 per Set 720

4.2 per Set 1000

4.3 per Set 720

4.4 per Set 1120

4.5 per Set 1520

4.6 per Set 1520

4.7 per Set 1920

4.8 per Set 2320

4.9 per Set 3120

4.1 per Set 1120

4.11 per Set 1520

4.12 per Set 1520

5

5.1 per Rack 1120

Replacement of Feeder cable with connectorization, weather proofing and earthing.

Microwave Installation, Commissioning, Integration &AT(Diameter<=0.6m)

Microwave Installation ( Diameter <=.6m)

Microwave Installation, Commissioning &AT(Diameter<=1.2m)

Microwave Installation ( Diameter <=1.2m)Microwave Commissioning & Integration ( Diameter <=1.2m)

Microwave Installation, Commissioning &AT(Diameter<=2.1m)

Microwave Installation ( Diameter <=2.1m)

BTS Power Plant(SMPS) Installation, Commissioning & ATP Sign-off

Core Room Power Plant(SMPS) Installation, Commissioning &ATP Sign-off(Capacity of power plant)

ZTE - Battery Bank Installation, Commissioning (240 AH) with ATP

BTS - Battery Bank Installation, Commissioning (240 ~ 500AH) With ATP

BTS - Battery Bank Installation, Commissioning (600 AH) With ATP

BTS - Battery Bank Installation, Commissioning (800 AH) With ATP

BTS - Battery Bank Installation, Commissioning (1000 AH ~ 1500AH) With ATPCore Room -Battery Bank Installation, Commissioning (1600 AH ~ 3000AH) With ATP(Core Room )Core Room -Battery Bank Installation, Commissioning (3000 AH Plus) With ATP(Core Room )

UPS and Battery(Internal) Installation& Commissioning &AT With Accessories &Terminals (Capacity <= 10KVA )

UPS and Battery(Internal) Installation& Commissioning &AT With Accessories &Terminals (Capacity <= 20KVA )

UPS and Battery(Internal) Installation& Commissioning &AT With Accessories &Terminals (Capacity <= 30KVA )

De-installation Scenario ZTE MSC /MGW/BSC/NGN/UMS/MSG/SS1/ Server Rack De-installation(All AC Server Rack) With Accessories & Terminals(With out material)

Page 11: 58784587-ZTE

5.2 per Rack 1120

5.3 DDF RACK De-installation per Rack 360

5.4 ODF Rack De-installation per Rack 360

5.5 per Site 1120

5.6 per Site 1520

5.7 per Sector 360

5.8 per Site 1120

5.9 per Site 1520

5.10 per Site 1920

5.11 per Site 360

5.12 per Set 360

5.13 per Set 400

5.14 per Set 720

5.15 per Set 720

5.16 per Set 1320

5.17 per Set 1720

5.18 per Set 2320

5.19 per Set 2320

6

6.1 per Site 1920

6.2 per Site 720

6.3 per Site 720

6.4 per Site 1520

6.5 per KM 6

Additional

7.1 480 Sector

7.2 320 Sector

7.3 400 Each Visit

7.4 600 Site

ZTE MSC /MGW/BSC/NGN/UMS/MSG/SS1/ Switch Rack De-installation(All DC Switch Rack) With Accessories & Terminals

De-installation of BTS(Indoor only) With Accessories (Exclusive of Feeder Cable & Antenna's)De-installation of BTS(outdoor only) With Accessories ( Feeder Cable & Antenna's)De-installation of Hoisting 1 Antenna Poles Hoisting De-installation of Existing MW & other Accessories (Inclusive of Feeder Cable & Antenna) (Antenna Diameter<=0.6m)De-installation of Existing MW & other Accessories (Inclusive of Feeder Cable & Antenna) (Antenna Diameter<=1.2m)De-installation of Existing MW & other Accessories (Inclusive of Feeder Cable & Antenna) (Antenna Diameter<=2.1m)De-installation of Existing MW & other Accessories (Exclusive of Feeder Cable & Antenna) only IDU' De-installation of Existing SMPS & other Accessories Battery Bank De- Installation (240AH) with cable & AccessoriesBattery Bank De- Installation (240 ~500AH) with cable & AccessoriesBattery Bank De-Installation (600 AH Plus)with cable & AccessoriesBattery Bank De- Installation (800AH) with cable & AccessoriesBattery Bank De- Installation (1000 ~ 1500AH) with cable & Accessories

Battery Bank De-Installation (1600~ 3000AH ) with cable & Accessories

Battery Bank De-Installation (3000AH Plus)with cable & Accessories

Transportation Scenario Supply of Wooden Boxes & Packing Materials - - (BTS-12mm Plywood Box, Wrapping up with Bubble Sheet, Rapper sheet & Thermo coal Packing inside Box.)

Packing of BTS including Loading & Unloading(at Site& Warehouse)

Transportation from Site to WH up to 100Km (Based One way distance)

Transportation from Site to WH up to 200Km (Based One way distance)

Transportation from Site to WH above 200Km (Based One way distance)

Feeder Installation(RF Cable Installation, connectoriztion, weatherproofing, labelling, earthing & routing of feeder cable , Excluding Antenna)Antenna Installation(Excluding feeder)

On Site Charge(Extra No of times)

Board expansion(Card Exchange)

Page 12: 58784587-ZTE

7.5 340 Sector

7.6 220 Sector

0 Microwave

7.7 3300 Hop

7.8 1980 Hop

7.9 1320 Hop

7.10 1120 Upgradation of IDU Hop

7.11 1300 Upgradation of ODU Hop

7.12 200 TMA De-Installation Nos.

7.13 600 Duplexer Installation Nos.

7.14 400 TMA Installation Nos.

0 Transportation

7.15 1960 Site

7.16 1400 Site

7.17 2200 Site

7.18 2320 Site

7.19 2200 Site

7.20 1400 Site

7.21 1600 Site

7.22 2400 Site

Feeder De-Installation(Deinsrtallation of RF Cable, connectors, weatherproofing, labelling, earthing, provide packing list and packaging, Excluding Antenna)Antenna De-Installation(Excluding feeder)

Microwave Installation ( Diameter >2.1m)Commissioning & Integration ( Diameter Microwave AT ( Diameter >2.1m)

Supply of Wooden Boxes & Packing Materials (BTS-12mm Plywood Box, Wrapping up with Bubble Sheet, Rapper sheet & Thermo coal Packing inside Box.)

Supply of Wooden Boxes & Packing Materials ( Accessories-12mm Plywood Box, Wrapping up with Bubble Sheet, Rapper sheet & Thermo coal Packing inside Box.)Supply of packing Material for Rack / Bay/ OLA without Cards (Wrapping with Stretch Wrapping Film 23 micron, 2 ply Corrugate sheet 140 GSM & 20 BS )Supply of packing Material for Rack / Bay/ OLA without Cards (Wooden / Ply Box- Pelletize Base 3" x 3 " wooden leg, 4" x 1" Wooden plunks for Frame, and 18 mm Ply at all 6 side. )

Supply of packing Material for Electronic Cards (Wrapping with Stretch Wrapping Film 23 micron, 2 ply Corrugate sheet 120/ 140 GSM & 17/ 20 BS, 20 / 25 mm Thermacole at all six side of Cartons & 5 Ply Cartons .

Supply of packing Material for Electronic Cards (Wooden / Ply Box- 4" x 3/4" Wooden plunks for Frame and 12mm Ply at all 6 side.)

Supply of packing Material for Electronic Cards ( 10 -12 cards are being packed in one carton box & carton box to be packed in Wooden / Ply)Supply of packing Material for Rack / Bay/ OLA with Cards (Wrapping with Stretch Wrapping Film 23 micron ( Double), 3 ply Corrugate sheet 140 GSM & 20 BS, 25 -30 mm Thermacole sheet at all six side.)

Page 13: 58784587-ZTE

7.23 2320 Site

7.24 320 Site

7.25 200 Site

7.26 720 Site

7.27 720 Site

0 Other Items for RFI

7.28 400 Floor

7.29 960 Floor

7.30 1200 Floor

0 Special AT

7.31 1800 Site

0 BSC/MSC HI & SC

7.32 2400 PDF Installation Site

Supply of packing Material for Rack / Bay/ OLA with Cards Wooden / Ply Box- Pelletize Base 3" x 3 " wooden leg, 4" x 1" Wooden plunks for Frame, and 18 mm Ply at all 6 side.Packing of BTS/MSC /MGW/BSC/NGN/UMS/MSG/SS1/ Server Rack (at Site& Warehouse)

Packing of BTS/MSC /MGW/BSC/NGN/UMS/MSG/SS1/ Server Rack's Accessories (at Site& Warehouse)

Loading & Unloading of BTS/MSC /MGW/BSC/NGN/UMS/MSG/SS1/ Server Rack (at Site & warehouse)

Loading & Unloading of BTS/MSC /MGW/BSC/NGN/UMS/MSG/SS1/ Server Rack 's Accessories (at Site & warehouse)

Labour charges for Unloading and shifting BTS/BSC/MSC/MGW/Server Rack, RF & Antenna, SMPS, BB and other items from site to up to 3 Floor

Labour charges for Unloading and shifting BTS/BSC/MSC/MGW/Server Rack, RF & Antenna, SMPS, BB and other items from site to up to 8 FloorLabour charges for Unloading and shifting BTS/BSC/MSC/MGW/Server Rack, RF & Antenna, SMPS, BB and other items from site to above 8 FloorSystem AT for Govt. Operator

Page 14: 58784587-ZTE

3600.0

ZTE Target Price(INR)

Page 15: 58784587-ZTE

80

28003600

0

48000

0

Page 16: 58784587-ZTE

0

0

Page 17: 58784587-ZTE
Page 18: 58784587-ZTE