- AUTO/MANUAL
B11 B12
B21 B22
DI1
DI2
DI3
DI4
DI5
DI6
DIIL
X22/1
DGND1X22/9
DGND2X22/10
B11 B12B11 B12
1
7
6
4
5
8
9
12
11
10
L1
L2
L3
T1
T2
T3
U2
V2
W2
(U2)
(V2)
(W2)
Sh
KW
KW
U2
V2
W2
(U2)
(V2)
(W2)
(11)
U1
V1
W1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
RDIO-01
X22/2
X22/3
X22/4
X22/5
X22/6
X22/11
1,5
EMERGENCYSTOP
1,5
SPARE
EMERGENCYSTOP
LOCAL CONTROL STATION
(NOTE 2)
3 Ph
60 Hz
INPUT
OUTPUT
NOTES:
1
2
3
4
- EMERGENCY STOP
- START VF- STOP VF
- SET POINT SPEED ADJUST
- LOCAL/REMOTE SELECTION
- SPEED FEEDBACK
- DRIVE READY- RUNNING- DRIVE FAULT- MOTOR CURRENT- MOTOR VOLTAGE
- ENERGIZED
TABLE N^1
(8)
B21 B22
(4)
(5)
SELECTOR
REMOTE
SELECTOR
LOCAL
(8)
(11)
(4)
SPARE33 34
(N^)
LEGEND
: MC POWER TERMINAL
: MOTOR POWER TERMINAL
: INDICATE DESIGNATION NUMBER OF CONDUCTOR
: TERMINAL IN DEVICE LOCATED IN THE FIELD
: 24 Vdc & 120 Vac DIGITAL INPUT
: VARIABLE FREQUENCY DRIVE TERMINAL
380 V
VARIABLE FREQUENCY DRIVE
: 120 Vac DIGITAL OUTPUT
CONTACTOR FILTERDISCONNECT
SWITCH - CB
CONTROL CIRCUIT
1.- THE COMMUNICATION CABLE BETWEEN THE DRIVE AND THE PROJECT S PAS (PROCESS AUTOMATION SYSTEM) HAS CAPABILITY TO MONITOR AND CONTROL THE DRIVE SPEED.
SIGNALS TO BE TRANSMITTED VIA SERIAL COMUNICATIONPROFIBUS DP TO PAS (PROCESS AUTOMATION SYSTEM)
A.- SIGNALS FROM CONTROL SYSTEM PAS TO VF
- PREDETERMINED SPEED
B.- SIGNALS FROM VF TO CONTROL SYSTEM PAS
C.- FROM LOCAL CONTROL STATION IN FIELD TO VF
- SELECTOR LOCAL/REMOTE
LOCREM
X
X(4)
(5)
SELECTOR
C22C11
C33
LOCREM
X
X
C22C11
C33
SELECTOR
- RUNNING TIME
FILTER
AC DCLINK INVESTORCONVERTER
FREQUENCY CONVERTERUNIT
COMMUNICATIONUNIT
PROFIBUS-DP
1
3
5
2
4
6
1
3
5
2
4
6
K01Q0120A
X21/2
1
R2
3
24Vdc X23/1
X25/2
X26/2
X27/2
X25/3
X26/3
X27/3
X23/2
GND0
READY
RUNNING
FAULT
X22/2
X21/3
X11/1
X11/2
X22/3
DI1
R01X80/4
X80/3
X80/1
X80/2
DRIVE
SPARE
RUNNING
13 13 14 43 44 A1 A2K01
R CSUP
K01
S05
Q01
K01
15
16
(13)
FROM 24 DCPOWER SUPPLY
F02
21
22
12
11
10
6
5
F02A50A2A
F0250A2A
F02
50A2A
2 4
1 3
X11/0
+24VdcX34/2
GND
X34/3
X22/7
X22/8
+24Vdc
+24Vdc
G
Y
A1
B1
A2
B2
S
PROFIBUS-DPCOMMUNICATION CABLE
CONNECTED TO OTHER DEVICE IN MC(BY INSTRUMENTATION)
AVAILABLE
CDP 312RCONTROL PANEL
X39/1
PE PE PE
AN
AL
OG
IN
PU
T A
ND
OU
TP
UT
A1
B1
A2
B2
S
GREEN
RED
GREEN
RED
SHIELD
X80
12
22
15
21
13
14
16
20
X10.1
10
11
(13)
(5)
(12)
(-)(+)
24 Vdc
PE(PE)
: MC TERMINAL
(13)
(12)
Q01
R02 (IMPULSE)
20
(12)
14
(8)(11)
RP
BA
-01
X21
PE (PE)
T1 (U2)
T2 (V2)
T3 (W2)
SPARE7 8S05
(BEHIND THE
13
14
C NO
AI
2
3
AO
LOCAL CONTROL STATION
PE
287CK110M1-LS
287CK110M1-VF287CK110M1-LS
287CK110M1-VF
287CK110M1-VF
BLUE DOOR )
T02400/120V
+/-5%;+/-2,5%200 VA
TEST 1 2
2.- CONNECTION DIRECTLY TO GROUNDING GRID ONLY IN HAZARDOUS AREAS.
23-0
7-2
012
q:\
share
d\r
0534200\0
2_eng_dw
g\0
7_ele
\02_in
t_app\d
iagra
mas e
squem
ati
cos\5
60-2
87-D
I-E
-105.d
gn
11:5
4:2
9
candiaf
0
TOROMOCHO PROJECT
C-560PROJECT :REV
MINERA CHINALCO PERU S.A.
DRAWING N^:
TITLE:
REV.DRAW APPROVED BY
FCT GBO GRO560-287-DI-E-105
CLIENT/PROJECT:
No
RE
VIS
ION
S
DESCRIPTION
0
DATE
ISSUED FOR CONSTRUCTION
287CK110M1-C01
287CK110M1-D01
287CK110M1-M01
17/07/12
LV SCHEMATICS DIAGRAM287-CK-110-M1
COOLER
287-CK-110-M1
287-CK-110-M1
(NOTE 3)
3.- LOCAL CONTROL STATION SHALL BE PROVIDED WITH SEPARATOR FOR DIFFERENT VOLTAGE LEVELS.
280-MC-006A
280-MC-006A