    STC CU/ECU alarms handling1/19 Procedure V1.0

    STC CU/ECU alarms handling procedure

    STC CU/ECU alarms handling procedure

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    2/19

    STC CU/ECU alarms handling2/19 Procedure V1.0

    Table of contents:

    1) Introduction

    2) Issue Description

    3) Technical Description

    3.1) Main CU/ECU alarms description.

    4) Clearance Actions

    5) Recommendations

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    3/19

    STC CU/ECU alarms handling3/19 Procedure V1.0

    1) Introduction

    The current document is intended to provide information about the CU/ECU alarm handling for

    STC network in order to improve the current behavior of alarms and HW issues in the CU/ECU

    module, it is based in the standard NSN operation documentation and should not be used

    as a replacement of such documentation but as a quick reference and support for the field

    engineers . For ex-Siemens BR equipment document number A50016-G5100-A001-07-

    76K5 is available and all personal working with ex-Siemens GSM radio equipment should

    be familiar with it, please refer to this documentation for further technical details.

    The high system functionality of the base station system is achieved by means of system-

    integrated routine tests. These routine tests continually check the correct functioning of the

    base station subsystems including the BTSEs. In most cases, the results of these routine

    tests are sufficient to localize the fault and clear it immediately at the BTSE.

    The modular design of the BTSE allows STC to clear a large percentage of faults in the

    system by replacing a defective module.

    Sometimes, however, it may happen that faults do not result from defective modules, but

    from interface problems in general (for example interrupted cables). In this case, special

    trouble shooting procedures for interfaces are provided. This maintenance concept

    guarantees a simple and fast fault clearance and leads to high operational efficiency.

    2) Issue description

    It has been found that the number of alarms received from the CU/ECU modules is higher than

    other vendors for equivalent modules within STC network. It is necessary to review the

    procedure being followed to clear these alarms and to study the current behavior and alarm

    clearance process.

    3) Technical description

    3.1) Main CU/ECU alarms description.

    The following items provide the error description which has to be taken into account when

    troubleshooting any CU/ECU alarm. The more common service affecting alarms in STC network

    are listed.

    3.1.1) The RF part of the CU/ECU has problems (34835)

    Error description:

    The power stage of the CU/ECU detected one of the following errors: Over temperature of the power

    stage Loop1 of Power stage does not close Loop2 of Power stage does not close FlexCU only: Overcurrent alarm

    Other words:

    The other word information provides additional information about every single alarm

    generate by ex-Siemens BSS, it is mandatory to analyze this information to define the

    appropriate action to be taken (please refer to annex C for details). For the case of alarm

    numbered 34835 RF part of the CU/ECU has problems the other words information is

    explained as followed:

    1718(D):

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    4/19

    STC CU/ECU alarms handling4/19 Procedure V1.0

    17=Bit field showing the errors of the power stage. If bit 0 -> error

    bit0: over temperature

    bit1: unused

    bit2: loop1 alarm (reduced output power)

    bit3: loop2 alarm (excessive output power)

    18=if 0: over current alarm (on FlexCU only)

    As per above information for this alarm octet 17 can take the hexadecimal values 1

    (overtemperature), 4 (reduced output power) or 8 (excessive output power).

    3.1.2) Loss of Board (22356)

    Error description:

    Board lost. Communication supervision detects a loss of board. In case of the board loss

    alarm caused by ACT all associated alarms will remain in the same status e.g. if BCOM is

    connected and fails no alarm would be sent.

    Other words:

    In this case the other words information does not provide any hint to the field engineer.

    3.1.3) RF power reflected warning (34910)

    Error description:

    The power amplifier detects reflected RF power.

    The error can be caused by:

    1. Cable problems in the TX/RX path, especially a defective TX cable from the CU/ECUto the

    combiner or a defective antenna cable.

    2. A defective CU/ECU or FlexCU

    As a consequence, the nominal output power is reduced for safety reasons:

    If TX power reduction = 0 dB, the output power is reduced by 6 dB.

    If TX power reduction = 2 dB, the output power is reduced by 4 dB.

    If TX power reduction = 4 dB, the output power is reduced by 2 dB.

    If TX power reduction > 4 dB, the power is not reduced.

    Further consequence: If after 20 seconds the error condition is removed, the alarm is

    cleared and the output power is set back to its original value. If the alarm persists after 20

    sec, the error condition persists and the alarm 34892 is raised.

    Other words:

    Octet 17 = A value unequal zero indicates a VSWR problem

    3.1.4) Device driver initialization failed (94)

    Error description:

    The initialization function of a device driver returned a non-zero error code to the OS, i.e.

    the initialization failed. The device driver can be identified by the address of its initialization

    function; its name can be found in the linker map file.

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    5/19

    STC CU/ECU alarms handling5/19 Procedure V1.0

    Other words:

    In this case the other words information does not provide any hint to the field engineer.

    3.1.5) RF power reflected into power stage (34892)

    Error description:

    The power amplifier detected reflected RF power. So either the connection between the

    power amplifier and the combining equipment is not correct or the power amplifier itself

    does not work correctly.

    Other words:

    In this case the other words information does not provide any hint to the field engineer.

    3.1.6) No startup-request after reset (24603)

    Error description:

    Reset-supervision failed: The core did not receive a startup-request message from the

    peripheral board after it was brought into boot-phase by reset. If this FER from object CU/ECU

    occurs sporadically, it can be ignored. This can occur when Booter falsely starts test SW

    instead of system SW because of a wrong transmission of test mode bits via CC Link.

    Other words:

    Not applicable

    3.1.7) Hardware error (4110)

    Error description:

    A hardware error was detected on one of the following BTSE boards: CCTRL,

    BBSIG/BBSIG44, TRXD/TRXD2(TPU), ALCO, TRXA, CCLK, LI, CORE, CU/ECU Possible

    causes: 1) A hardware test procedure has detected a chip error 2) BBSIG/BBSIG44:Timout at loading BB1(/BB2) with Boot-SW or Load-SW TRXD: Timeout at loading

    DR1/DR2 with Boot-SW or Load-SW TRXD2: Timeout at loading LEA with Load-SW

    Because of HW tolerances this error can occur during startup of TPU (TPU1 HW version)

    with the following additional infos: HW test number = 0b, HW test result = 01.

    The TPU is afterwards recovering successfully without any problem! NOTE: This error

    replaces the former error CBM_AEID_HW_ERROR beginning with BR3.0. It provides more

    detailed error information. NOTE2: For EdgeCU/FlexCU in BR8.0 this alarm was enhanced

    with more additional information about failures on HIT DSPs.

    Other words:

    Not applicable

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    6/19

    STC CU/ECU alarms handling6/19 Procedure V1.0

    3.1.8) Hardware Error on CU/ECU detected by BIC (20603)

    Error description:

    Power Supply Unit (PSU) does not work correctly

    Other words:

    Not applicable

    3.1.9) Any of the PLLs shows lockproblems (34836)

    Error description:

    Any of PLLs on the SIPRO has lockproblems.

    Other words:

    Not applicable

    3.1.10) Test Result failed (28675)

    Error description:

    The initiated PerformTest or AutomaticTest don't pass. It fails, see corresponding Test

    Report.

    Other words:

    Not applicable

    3.1.11) No phys. Recovery after BTSE restart (30784)

    Error description:

    No physical recovery is performed for a faulty processor board after a BTSE restart (theboard remains in state DISABLED.NOT_INSTALLED). With this alarm the board is set to

    DISABLED.FAILED in order to indicate on LMT and RC that there is a problem with this

    board (note that the original alarm is no longer available after a BTSE restart).

    Other words:

    Not applicable

    3.1.12) Error in Flash or mismatch with database (34832)

    Error description:

    There are two possibilities for this error: Either the cell allocation number in the database

    does not match to the actual hardware, or the ramping FLASH could not be read

    completely.

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    7/19

    STC CU/ECU alarms handling7/19 Procedure V1.0

    Other words:

    Not applicable

    3.1.13) Inter board communication timeout (24581)

    Error description:

    A task located on the core has not received the expected message from a peripheral board.

    Other words:

    Not applicable

    3.1.14) Local AE-queue full (20543)

    Error description:

    The local AE-Queueing buffer is full.

    Other words:

    Not applicable

    3.1.15) Error in downlink message from COP/HIT (34841)

    Error description:

    U1-BIC (baseband information controller) received a message from COP (coding/decodingproc essor on CU/ECU/GCU) / HIT (highly integrated transceiver, DSP on ECU/FlexCU ) in which either:

    The checksum is not correct.

    The downlink burst type is illegal.

    The training sequence code is illegal.

    The time slot number is wrong.

    The number of received data packet(s) is wrong.

    The packet size is wrong.

    There is a collision of downlink data on FlexCU.

    The error can be caused by:

    Cable problems on CC-Link

    A defective COBA

    A defective CU (GCU/ECU/FlexCU)

    Other words:

    Not applicable

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    8/19

    STC CU/ECU alarms handling8/19 Procedure V1.0

    3.1.16) Critical SELIC problem (8260)

    Error description:

    A SELIC-ASIC indicates a critical problem. The problem does not allow any further processing of theSELIC-ASIC. The following critical problems can occur: * Illegal CC Link configuration * RAM BIST

    failure.

    Other words:

    Not applicable

    3.1.17) Diversity Receive Branch Failed (34837)

    Error description:

    A diversity receive branch failed because of a bad signal receive level or because of a bad

    signal to noise ratio. The error can be located in the whole receive path, i.e.: - at the

    antenna - at the RF cabling - in the combining equipment - inside the CU/GCU/ECU/FCU A

    CU/GCU/ECU/FCU test can give a hint whether the error is situated in the CU/GCU/ECU or

    outside of it. If the CU/GCU/ECU/FCU test fails the error is located inside the

    CU/GCU/ECU/FCU, otherwise the error is located outside. Cause for this alarm may also

    be a strong interfering signal, which disturbs the receiver. In this case the

    CU/GCU/ECU/FCU test should pass. The alarm changes the availability status of the

    CU/GCU/ECU/FCU to "degraded". It is recommended to perform a CU/GCU/ECU/FCU test

    in order to locate the error. The CU/GCU/ECU/FCU leaves the availability status

    "degraded" if: - both receivers have a good receive quality - the supervision is switched off -

    reception with diversity is switched off - Call Processing is blocked i.e. the

    CU/GCU/ECU/FCU is locked or a fault occured on an object which is necessary for this

    TRX.

    Other words:

    1718(D):

    17=(G)CU (Octet 1 = 0x6a):

    Shows the number of timeslots of the main receiver which do not receive properly.

    ECU/FCU (Octet 1 = 0x62):Alarm type discriminator: operating mode

    0: Invalid1: 2Rx

    2: 4Rx3: Switch Beam (not supported in BR8)

    4: 4RxTxDiv5: 0Rx

    18=(G)CU (Octet 1 = 0x6a):

    The upper four bits show the number of timeslots of the main receiver which do not receive properly

    due to a bad signal to noise ratio.The lower four bits show the number of timeslots of the main receiver which do not receive properly

    due to bad signal strength.ECU/FCU (Octet 1 = 0x62):

    Processor ID of alarm originator1920(D):

    19=(G)CU (Octet 1 = 0x6a):

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    9/19

    STC CU/ECU alarms handling9/19 Procedure V1.0

    This octet shows the number of timeslots of the diversity receiver which do not receive properly.ECU/FCU (Octet 1 = 0x62):

    Equalizer diversity configuration

    20=(G)CU (Octet 1 = 0x6a):

    The upper four bits show the number of timeslots of the diversity receiver which do not receiveproperly due to a bad signal to noise ratio.

    The lower four bits show the number of timeslots of the diversity receiver which do not receiveproperly due to bad signal strength.

    ECU/FCU (Octet 1 = 0x62):Shows the number of timeslots of the 1st receive branch which do not receive properly.

    2122(D):

    21=ECU/FCU (Octet 1 = 0x62):

    The upper four bits show the number of timeslots of the 1st receive branch which do not receiveproperly due to a bad signal to noise ratio.

    The lower four bits show the number of timeslots of the 1st receive branch which do not receiveproperly due to bad signal strength.

    22=ECU/FCU (Octet 1 = 0x62):

    Shows the number of timeslots of the 2nd receive branch which do not receive properly.

    2324(D):

    23=ECU/FCU (Octet 1 = 0x62):

    The upper four bits show the number of timeslots of the 2nd receive branch which do not receive

    properly due to a bad signal to noise ratio.The lower four bits show the number of timeslots of the 2nd receivebranch which do not receive properly due to bad signal strength.

    24=ECU/FCU (Octet 1 = 0x62):

    Shows the number of timeslots of the 3rd receive branch which do not

    receive properly.2526(D):

    25=ECU/FCU (Octet 1 = 0x62):

    The upper four bits show the number of timeslots of the 3rd receivebranch which do not receive properly due to a bad signal to noise

    ratio.

    The lower four bits show the number of timeslots of the 3rd receivebranch which do not receive properly due to bad signal strength.

    26=ECU/FCU (Octet 1 = 0x62):

    Shows the number of timeslots of the 4th receive branch which do notreceive properly.

    2728(D):

    27=ECU/FCU (Octet 1 = 0x62):

    The upper four bits show the number of timeslots of the 4th receivebranch which do not receive properly due to a bad signal to noise

    ratio.The lower four bits show the number of timeslots of the 4th receive

    3.1.18) Increased path loss difference (38956)

    Error description:

    The absolute mean value of the path loss difference of the corresponding TRX (see additional info)is above the specified alarm threshold (RFL Alarm Threshold). This indicates possible hardware

    degradation of the BTS RF path. The path loss difference is represented as a signed integer numberwith 4 bytes length. Positive values indicate higher UL path loss than DL path loss -> Degradation at

    the receiver equipment.

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    10/19

    STC CU/ECU alarms handling10/19 Procedure V1.0

    Negative values indicate higher DL path loss than UL path loss -> Degradation at the transmitterequipment. The alarm contains some information about the responsible HW object. With this

    information all affected RF cabling, boosters, combiners, power amplifiers, etc. can be located byusing the wiring data of the relevant cell. The reported TRX ID keeps it's validity up to the next

    configuration change. Locking a BTS RFLoopBack scanner with active alarm conditions will ceasethese alarms, even if the error condition still exists.

    Other words:

    1718(D):

    17=TRX ID, octet 1 (LSB)

    18=TRX ID, octet 2

    1920(D):

    19=TRX ID, octet 3

    20=TRX ID, octet 4 (MSB)

    2122(D):

    21=Measurement count, octet 1 (LSB)

    22=Measurement Count, octet 2

    2324(D):

    23=Measurement count, octet 3 (MSB)

    24=call count, octet 1 (LSB)

    2526(D):

    25=call count, octet 2

    26=call count, octet 3 (MSB)

    2728(D):

    27=mean value of path loss difference, octet 1 (LSB)

    28=mean value of path loss difference, octet 2

    2930(D):

    29=mean value of path loss difference, octet 3

    30=mean value of path loss difference, octet 4 (MSB)

    4) Clearance actions

    Most of the alarms can appear in the CU/ECU only when the traffic over that particular CU/ECU

    increases e.g. The RF power reflected in the CU/ECU will depend on the traffic carried by this

    CU/ECU in case that particular CU/ECU is not carrying the BCCH.

    Due to this behavior is mandatory to define within O&M team the responsibility of

    detecting and tracking the actual faulty modules, since the initial test of a module not

    working properly can pass successfully during low traffic conditions and this can lead to the

    reuse of a faulty module in another site. It is also recommended to switch the BCCH to the

    CU/ECU that was generating the alarm after this is cleared.

    Some of the alarms could also be caused by environmental issues in the site itself e.g. over

    temperature, so it is also important to keep record and to track each site behavior when it

    comes to faulty modules and alarms cleared in that particular site to easily recognize any

    pattern that may show up.

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    11/19

    STC CU/ECU alarms handling11/19 Procedure V1.0

    4.1.1) The RF part of the CU/ECU has problems

    The initial step to clear this alarm is to perform a test on the module; this can be done

    remotely from the RC or the BSC. If the test is failed the module can be deleted and

    recreated to force a restart, if the module keeps disabled the O&M engineer should visit the

    site and swap the CU/ECU another with CU/ECU of the same BTSE, this will rule out a possiblefailure in the CU/ECU position of the rack and provide a HW rest of the module. If the same CU/ECU

    is disabled after swapping, it has to be replaced and sent to repair (please refer to annex A

    and B for further details).

    If the test passes or the module is recovered after re-creation or swap it is necessary to

    keep track of the behavior of this CU/ECU to make sure it does not fail again, in case the alarm

    is generated again and the other words information indicate an over temperature problem it

    is recommended to visit the site to make sure there is no physical issue with the rack e.g.

    missing cover plate, rack door open etc

    If the alarm reappears the module has to be sent for repair (please refer to annex A and B

    for further details).

    4.1.2) Loss of board alarm, Hardware error Alarm or Test result failed alarm

    The initial step to clear this alarm is to perform a test on the module; this can be done

    remotely from the RC or the BSC. If the test is failed the module can be deleted and

    recreated to force a restart, if the module keeps disabled the O&M engineer should visit the

    site and swap the CU/ECU with another CU/ECU of the same BTSE, this will rule out a possible

    failure in the CU/ECU position of the rack and provide a HW rest of the module. If the same CU/ECU

    is disabled after swapping, it has to be replaced and sent to repair (please refer to annex A

    and B for further details).

    If another CU/ECU does not work in the faulty CU/ECU position in the rack.

    the CU backplane need to be checked

    If the test passes or the module is recovered after re-creation or swap it is necessary to

    keep track of the behavior of this CU/ECU to make sure it does not fail again, in case of a new

    failure the module should be replaced and sent for repair (please refer to annex A and B for

    further details)

    4.1.3) RF power reflected warning and RF power reflected into powerstage

    These two alarms are closely related and normally generated due to a problem outside the

    module, initially the module has to be tested remotely but the test its very likely to be

    successful (the CU/ECU has to be sent to repair if the test fails), in case and the alarm appears

    again the O&M engineer has to visit the site to pinpoint the failure.

    The failure can be located in:

    1) The physical TX output port of the CU/ECU.

    2) The TX FlexiCable connecting the CU/ECU with the combiner.

    3) The TX input port of the antenna combiner.

    4) A high VSWR in the feeder (indicated in the other words of the RF power reflected

    warning)

    If the test is successful from the RC or BSC and the alarm appears again the O&M

    engineer should visit the site and sequentially perform the following steps:

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    12/19

    STC CU/ECU alarms handling12/19 Procedure V1.0

    A) Perform a visual inspection of all flexicables and input/output ports of the CU/ECU and

    corresponding combiner. Replace the related module/flexicable in case any physical

    damage is found.

    B) Perform a VSWR test of the corresponding feeder. If necessary measure the insertion

    loss of the feeder to make sure it is within the range define by the feeder manufacturer.

    Items A and B should pinpoint most of the possible reasons for this alarm, in case it is still

    not clear where the problem is located the O&M engineer should continue as follows:

    C)

    1- Swap the CU/ECU with the alarm with another CU/ECU of the same BTSE for example CU/ECU:X.2- Swap the TX flexicable with another one from the same BTSE for example CU/ECU:Y.

    D)

    1-If the alarm moved to position X the CU/ECU has to be changed.

    E) If the alarm stayed in the same CU/ECU position, swap the combiner where the CU/ECUis

    connected to make sure the fault is located in the combiner, once this is determine the

    combiner should be replaced and sent for repair (please refer to annex A and B for furtherdetails).

    4.1.4) Device driver initialization failed

    The initial step to clear this alarm is to perform a test on the module; this can be done

    remotely from the RC or the BSC. If the test is failed the module can be deleted and

    recreated to force a restart, if the module keeps disabled the O&M engineer should visit the

    site and swap the CU/ECU another with CU/ECU of the same BTSE, this will rule out a possible

    failure in the CU/ECU position of the rack and provide a HW rest of the module. If the same CU/ECU

    is disabled after swapping, it has to be replaced and sent to repair (please refer to annex A

    and B for further details).

    If the test passes or the module is recovered after re-creation or swap it is necessary to

    keep track of the behavior of this CU/ECU to make sure it does not fail again, in case of a new

    failure the module should be replaced and sent for repair (please refer to annex A and B for

    further details).

    Alarms in items 3.1.6 to 3.1.14 should be troubleshooted as per 4.1.4

    4.1.5) Error in downlink message from COP/HIT (34841)

    Initally perform a visual inspection including the CC-link cables related to the CU/ECU with the

    alarm (replace if necessary). Then proceed to troubleshoot as per 4.1.4, if the alarm

    persists replace the COBA of the site.

    4.1.6) Critical SELIC problem (8260)

    Proceed as per 4.1.5.

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

    2- In case the alarm moves to the position Y where the flexicable was moved to, this flexicable has to be replaced

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    13/19

    STC CU/ECU alarms handling13/19 Procedure V1.0

    4.1.7) Diversity Receive Branch Failed (34837) for CU or ECU

    As mentioned in the error description this alarm indicated a bad signal received level or a

    bad signal to noise ratio. Normally the problem is located outside the CU in the RX path

    (Antenna, Flexicable or Combiner). This alarm does not leave the related TRX in disabled

    state so the CU keeps carrying traffic, this requires for the field engineer to have all thenecessary precautions to avoid any call drops (please refer to Annex B).

    4.1.8) Increased path loss difference (38956)

    Based on the other words information it is possible to determine if a problem is present in

    the RX or the TX path. If the problem is present in the RX path O&M engineer should

    proceed as per 4.1.7 otherwise perform the procedure described in 4.1.3.

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

    2- To find out the CU is healthy or not perform test either locally or from remote so if

    A- The test failed the CU is faulty and need to be changed.B- If the test pass this means the CU is healthy and the problem outside the CU

    Either

    1- If the alarm is present in more than one CU/ECU in more than one sector in the site or, if the

    other words information indicates a bad signal to noise ratio in more than one RX path this

    may indicate an interference problem in the site, contact OPT for support.

    1) The physical RX output port of the CU.

    2) The RX FlexiCable connecting the CU with the combiner.

    3) The RX input port of the antenna combiner.

    4) High insertion loss in the antenna feeder.

    FLM has to do swap for each mentioned items , the CU with other one the site for example CU:X,Swap The RXFlexi cables with other ones in the site for example with the two RX cables of CU:Y&Z.

    Swap the related Combiner with other combiners of the mentioned CUs (X/Y/Z) for example with combiner

    Of CUs ( A,B,C,&D)

    Swap the related Feeder with other one in the same sector from BTSE side for example with feeder of CU:M&N.

    After that keep monitoring the site and check the alarm where will be appeared either

    In CU:X means the CU is faulty, CU:Y or Z so changed the related RX cable, one of CU X,Y or Z so check the

    Combiner or in the CUs M&N so the feeder need to be checked.

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    14/19

    STC CU/ECU alarms handling14/19 Procedure V1.0

    5) Recommendations

    - All the replacements procedures have to be performed as indicated in the official

    NSN operating documentation; this includes the usage of all the ESD precautions

    among all the others recommendations as indicated in the Maintain Hardware

    document (A50016-G5100-B326-04-7620).

    - It is recommended to keep track of the tested modules and to define if the

    replacement has to be done even if the test of module is successful.

    - O&M engineer on the field should keep a record of the replaced modules with its

    serial number to avoid the usage of a replaced module in a different site. This could

    happen since a faulty module can be enabled right after installation if there is no

    traffic in it. Since the rotation of the field engineers is very frequent in STC a proper

    track of the replacement is mandatory to avoid this kind of situations.

    - The uninstalled modules (spare parts or replaced faulty modules) should be packed

    and transported all the time as received from NSN to avoid any further damage in a

    faulty module or a fault in a spare due to mishandling.

    - STC could designed a checklist database where the parties involved can register

    the steps performed in one particular module and can also check and advise based

    on such information.

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    15/19

    STC CU/ECU alarms handling15/19 Procedure V1.0

    ANNEX A. Module replacement and ESD precautions

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    16/19

    STC CU/ECU alarms handling16/19 Procedure V1.0

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    17/19

    STC CU/ECU alarms handling17/19 Procedure V1.0

    Annex B. Avoiding the lost of calls

    Khalil Al Ngashy

    NSN CM Team NSN MS Use

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    18/19

    STC CU/ECU alarms handling18/19 Procedure V1.0

    NSN CM Team NSN MS Use

    Khalil Al Ngashy

    Annex C. Other words

  • 7/30/2019 55434737 CU ECU Alarm Handling Procedure

    19/19

    STC CU/ECU alarms handling19/19 Procedure V1.0

    When connected to the LMT the information of the alarm will be displayed as below:

    The additional words are always presented in octes as in above example, for this particular

    example octet 4 is H61, octet 15 H07 and octet 15 HFF.

    NSN CM Team NSN MS Use