4
G3A-b 72.5/145kV 325/650kV 140/275kV 50/60Hz 1250/2000/2500/3150 A 31.5/40kA-3sec. 0.7 MPa(GCB)/0.7 MPa(GIS) IEC Type Rated voltage Rated lightning impulse withstand voltage Rated power frequency withstand voltage Rated frequency Rated current Rated short time withstand current Rated gas pressure (abs.) Applied standards Ratings       G       3       A          b

Transcript of 5410-3.pdf

Page 1: 5410-3.pdf

8/10/2019 5410-3.pdf

http://slidepdf.com/reader/full/5410-3pdf 1/4

G3A-b

72.5/145kV

325/650kV

140/275kV

50/60Hz

1250/2000/2500/3150 A31.5/40kA-3sec.

0.7 MPa(GCB)/0.7 MPa(GIS)

IEC

Type

Rated voltage

Rated lightning impulse withstand voltage

Rated power frequency withstand voltage

Rated frequency

Rated currentRated short time withstand current

Rated gas pressure (abs.)

Applied standards

Ratings

      G      3      A   -      b

Page 2: 5410-3.pdf

8/10/2019 5410-3.pdf

http://slidepdf.com/reader/full/5410-3pdf 2/4

Certificate of KEMA

Typical Construction of 72.5145kV GIS

SF6gas

Insulators

Live partsCT/PT

Eathed parts

Disconnectorandmaintenanceearthing switch(DS/M-ES)

 Voltage transformer(VT)

Earthing switch(ES)

Cable sealing end(CH)

Disconnector(DS)

Disconnector andmaintenance earthingswitch(DS/M-ES)

Gas circuit breaker(GCB)

Current transformer(CT)

Bushar

Page 3: 5410-3.pdf

8/10/2019 5410-3.pdf

http://slidepdf.com/reader/full/5410-3pdf 3/4

Insulating spacer

Insulating rod

Operatingmechanism

Plane View

Side View

Motor Charged Spring Mechanism of GCB Operating Mechanism of 3 Position Type DS/M-ES

Feature of 3 Position Type for Busbar DS/M-ESGas Circuit Breaker

Puffer piston

Exhaust hole

Puffer cylinderArcing contact

Arcing contactNozzle

(A) Initial stage of current interruption

DS : ONES : OFF

DS : OFFES : OFF

DS : OFFES : ON

(B) Final stage of current interruption

Effective arc energy transfer to pressure rise

Optimum puffer cylinder dimensions

Reduce the driving energy

Principle of advanced hybrid puffer

Design phyrosophy for interrupting chanber

Easy access to maintenance partsCompactness for small size of mechanical box

Reduced number of partsOnly one driving mechanismCompactnessPhysically mechanical interlock system

Opening spring

Motor

Closing spring

Closing coil

Opening coil

Aux.sw

Fixed contact

of ES

Fixed contact of DS

Moving contactof DS/ES

Page 4: 5410-3.pdf

8/10/2019 5410-3.pdf

http://slidepdf.com/reader/full/5410-3pdf 4/4

Single Line Diagram

Typical Arrangement (Double Busbar System)

L I N E

B / C BA NK

Double Busbar System

5410-3 '08-04T1

Transmission Distribution & Industrial Systems Company1-1, Shibaura 1-chome, Minato-ku, Tokyo 105-8001, Japan

Phone. +81-3-3457-3658 Facsimile. +81-3-5444-9168

The data given in this catalog are subject to change without notice.

LINE

LCP

BB-2GCB

CT

CT

BB-1

DS/ES

DS/ES

VT

DS

DS DS

ES

ES

CT

GCB

CT

H-ES

CH

LINE B/C BUS-VT

VT

DS

DS DS

ES ES ES

ES

ES

VT

VT

ES

CT

CT

GCB

CTGCB

CT

H-ES

CH

DS

BANK

DS DS

ES

CT

GCB

CT

CH

H-ES

BB-2

BB-1

DS

       5       5        0        0

        3        0        0        0

       5       5        0        0

2900

LCP

BB-2 CT

CT

CH

H-ES

GCB

BB-1

DS

DS/ES

4000

3.0 t 3.0 t

        3        4        0        0

        4        0        0        0

800

LINE

800 800 800

LINE

B/C BANK

BUS-VT

       5       5        0        0

LCP

BB-2 CT

CT

DS/ES

CH

VT

H-ES

GCB

BB-1

DS

DS/ES

4000

3.0 t

        3        4        0        0