536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de...

14
1 4005304-04 President Cast Front Insert Model 536CXBI Approved for use with Valor heater 530 & 530 insert models only ©2018, Miles Industries Ltd. HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. DANGER ! A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. Notes: This kit must be installed or serviced by a qualified installer, service agency or gas supplier. These instructions are to be used in conjunction with the main installation instructions for the above listed heater models. INSTALLER Leave this manual with the appliance. CONSUMER Retain this manual for future reference. Applications The President Cast Front for Insert 536CXBI is intended to install on the Valor Portrait 530 heater when installed as an insert fireplace. The Valor model 530 heater with the 536CXBI President Cast Front and 582 or 583 Closure Plate comes ready for installation as an insert unit into existing solid-fuel burning fireplaces provided space and local codes permit. Requires the use of a 582CPB or 583CPB Closure Plate (sold seperately) INSTALLATION MANUAL Portrait

Transcript of 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de...

Page 1: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

14005304-04

President Cast Front Insert Model 536CXBIApproved for use with Valor heater 530 & 530 insert models only

©2018, Miles Industries Ltd.

HOT GLASS WILL CAUSE BURNS.

DO NOT TOUCH GLASS UNTIL COOLED.

NEVER ALLOW CHILDREN TO TOUCH GLASS.

DANGER!

A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.

Notes: This kit must be installed or serviced by a qualifi ed installer, service agency or gas supplier. These instructions are to be used in conjunction with the main installation instructions for the above listed heater models.

INSTALLERLeave this manual with the appliance.

CONSUMERRetain this manual for

future reference.

ApplicationsThe President Cast Front for Insert 536CXBI is intended to install on the Valor Portrait 530 heater when installed as an insert fi replace. The Valor model 530 heater with the 536CXBI President Cast Front and 582 or 583 Closure Plate comes ready for installation as an insert unit into existing solid-fuel burning fi replaces provided space and local codes permit.

Requires the use of a 582CPB or 583CPB Closure Plate (sold seperately)

INSTALLATION MANUAL

Portrait

Page 2: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

2

Casting TolerancesDue to the nature of cast iron, dimensional consistency may vary from one unit to the next and some variation in surface fi nish and fl atness is to be expected. We have done our best to control and make allowance for this; however some variation is inevitable.

Top Baffle

Front Casting withBarrier Screen

Kit Contents

536CXBI1 Front Casting Assembly with Barrier Screen1 Top Baffl e1 Pack of Screws

582CPB or 583CPB Closure Plateeach kit supplied with the following:

1 Closure plate2 Mounting brackets4 M4 x 12 mm screws6 No 8 x 3/8 screwsThe two models of closure plates vary in size. See following pages for Dimensions and installation of the closure plates.

Mounting Brackets

583 Closure Plate582 Closure Plate

536CXBI

582CPB or 583CPB

Page 3: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

3

7/8”

25-1

/4”

‘A’

‘B’

20”

8-3/

4”

‘D’

‘E’

MantellegSee table

19-1

/4”

3/8”8-3/4”

3/4”

3/4” 3/4”

4-1/8”

Ensure base of heater is flush with finished hearth height, otherwise cast front will not fit.

2 x 3” dia. colinear

vent

2 x 3” dia. colinearadaptor

4-3/4”x 3” dia. co-axialadaptor

530 engine with 556CLA co-linear adaptor

530 insert engine with standard co-linear vent

530 insert engine with 530CVA co-axial vent adapter

Do not putfurniture or objects within 36” of front of appliance

Mantel depth “A” Min. clearance “B”Up to 7” 4”Above 7” up to 8” 5”Above 8” up to 9” 7”Above 9” up to 10” 8”Above 10” up to 12” 9”More than 12” 9”+extra 1” for every

1” depth above 12”

Mantel leg projection “D”

Min. clearance from appliance side “E”

Up to 8” 2”More than 8” 6”

Insert dimensions for 3 engine confi gurationsThese dimensions are for non-combustible installations

Clearances

Page 4: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

4

Installation1. Fit the top baffl e under the top panel of the

appliance case. Secure with 2 thread forming screws.

2. Locate and secure mounting brackets to side of engine with 2 screws each side; brackets are set forward from liner body front approximately 10mm (3/8”)

582CPB or 583CPB Closure Plate (required)Dimensions

30” (762 mm)

33” (

838

mm

)

583CPB Closure Plate

26” (660 mm)

31” (

787

mm

)

582CPB Closure Plate

Page 5: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

5

3. Secure Closure Plate to Mounting Brackets with 6 thread forming screws.

4. If the hooks have been shipped loose with the cast front, fi x them to the front at its top corners. Hang the front on the appliance.

Page 6: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

6

Cleaning

To clean the barrier screen and the cast front use a soft brush.If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.To clean the fi replace glass window, refer to the owner’s manual supplied with the appliance.DO NOT clean the glass with ammonia.Removing the front unitUnhook the front unit. Lift it up by holding the decorative grille. DO NOT lift it by holding the top.Always securely replace the window and the front with barrier screen before lighting.

WARNINGFOR YOUR SAFETY, ensure the barr ier FOR YOUR SAFETY, ensure the barr ier screen is reinstal led on the f i replace screen is reinstal led on the f i replace after maintenance.after maintenance.

WARNINGDO NOT TOUCH THE BARRIER SCREEN, DO NOT TOUCH THE BARRIER SCREEN, THE CAST FRONT OR THE GLASS WHILE THE CAST FRONT OR THE GLASS WHILE THEY ARE HOT! THEY ARE HOT! Let the fireplace cool first Let the fireplace cool first before cleaning it.before cleaning it.

Page 7: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

7

Repair Parts List

1

11

8

7

109

62

34

5

# Description Number Alternate no.1 Front Unit 568979 040A5192 Door Hinge Bolt 568999 420K5583 Ashpan Door 568989 540K048AZ4 Washer 532529 100B8105 Magnet unit 569009 020A0856 Front Casting 568929 050A255AZ7 Front Casting Hook RH 568949 330A9238 Front Casting Hook LH 568939 330A9229 Top Casting 568969 550K065AZ

10 Top Baffl e 569019 340B252AZ11 Barrier Screen 4003359 400335912 Closure Plate 582 - 26” wide 31” high 4005203AZ13 Closure Plate 583 - 30” wide 33” high 4005198AZ14 Mounting Bracket (2) with each plate 4005199

Designed and Manufactured by / forMiles Industries Ltd.

190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1Tel. 604-984-3496 Fax 604-984-0246

www.valorfi replaces.com

Because our policy is one of constant development and improvement, details may vary slightly from those given in this publication.

14

12 (582CPB)

13 (583CPB)

Page 8: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

8

Devanture de fonte President pour encastrables 536CXBIHomologuée pour usage avec les foyers Valor 530 et 530 encastrables seulement

ApplicationsLa Devanture de fonte President pour encastrables 536CSBI est conçue pour installer avec le foyer Valor Portrait 530 dans une application encastrable.Mis ensemble, le foyer Valor 530, la Devanture de fonte 536CXBI et la Plaque de fi nition 582CPB ou 583CPB fournissent les éléments nécessaires à l’installation comme encastrables dans les foyers à combustibles solides lorsque l’espace et les codes locaux le permettent.

Exige l’usage de la Plaque de fi nition 582CPB ou 583CPB (vendues séparément)

Note : Cette devanture doit être installée par un installateur qualifi ée, une agence de ser-vice certifi ée ou un fournisseur de gaz. Ces instructions doi-vent être utilisées conjointe-ment avec les instructions fournies avec le foyer.

I N S TA L L AT E U RLaissez cette notice

avec l’appareilC O N S O M M AT E U RConservez cette notice

pour consultation ultérieure

VITRE CHAUDE - RISQUE DE BRÛLURES.

NE TOUCHEZ PAS UNE VITRE NON REFROIDIE.

NE LAISSEZ JAMAIS UN ENFANT TOUCHER LA VITRE.

L’écran pare-étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection des enfants et des personnes à risques.

DANGER!

PortraitDIRECTIVES D’INSTALLATION

LE PREMIER FOYER À GAZ RADIANT

MC

®

Page 9: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

9

Variations de la fonteDe par leur nature, deux articles de fonte fabriqués du même moule peuvent montrer de légères variations dans leurs dimensions et leur fi nition. Nous faisons tout ce qui est possible pour limiter ces variations qui ne peuvent cependant pas être éliminées.

Déflecteur du haut

Devanture de fonteavec Pare-étincelles

Contenu des kits536CXBI1 Devanture de fonte avec Pare-étincelles1 Défl ecteur du haut1 Ensemble de vis

Plaques de fi nition 582CPB ou 583CPBchaque Plaque de fi nition fournie avec les articles suivants :

1 Plaque de fi nition2 Supports de montage4 Vis M4 x 12 mm6 Vis no 8 x 3/8Les deux de plaques de fi nition off ertes sont de taille diff érente. Consultez les pages suivantes pour connaître les dimensions et les directives d’installation des plaques de fi nition.

Supports de montage

Plaque de finition 583

Plaque de finition 582

536CXBI

582CPB ou 583CPB

Page 10: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

10

‘A’

‘B’

‘D’

‘E’

3/8”(10 mm) 7/8”

(22 mm)

3/4”(19 mm)

3/4”(19 mm)

3/4”(19 mm)

Raccord colinéaire à 2 buses de 3” dia.

Évent colinéaire 2 buses de 3” dia. Raccord

coaxial4-3/4 x 3” dia.

8-3/4”

(222 mm)

8-3/4” (222 mm)

Manteau

Assurez-vous que la base du foyer est

égale à la surface de la dalle protectrice

devant le foyer; autre-ment la devanture de fonte ne pourra

pas être installée.

25-1

/4” (

641

mm

)

19-1

/4” (

489

mm

)

20” (508 mm)

Patte demanteau-voir table

Ne placez aucun meuble ou objet à

moins de 36” (914 mm)du devant du foyer

Foyer 530 avec raccordcolinéaire 556CLA

Foyer 530 encastrable avecraccord d’évent coaxial 530CVA

Foyer 530 encastrableavec évent colinéaire

4-1/8”(105 mm)

Profondeur de manteau “A” Dégagement minimum “B”Jusqu’à 7” (178 mm) 4” (102 mm)De 7” à 8” (178 à 203 mm) 5” (127 mm)De 8” à 9” (203 à 229 mm) 7” (178 mm)De 9” à 10” (229 à 254 mm) 8” (203 mm)De 10” à 12” (254 à 305 mm) 9” (229 mm)

Plus de 12” (305 mm)

9” (229 mm) + 1” (25 mm) extra pour chaque 1” (25 mm) de profondeur au-

dessus de 12” (305 mm)

Projection de la patte de manteau “D”

Dégagement minimum du côté de l’appareil “E”

Jusqu’à 8” (203 mm) 2” (51 mm)Plus de 8” (203 mm) 6” (153 mm)

Dimensions, applications encastrables - 3 confi gurations Ces dimensions sont pour installations incombustibles

Dégagements

(553 mm)

(708

mm

)

Page 11: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

11

Installation1. Placez le défl ecteur du haut sous le panneau de

dessus de la boîte de foyer. Fixez-le avec 2 vis autoformeuses.

2. Positionnez et fi xez les supports de montage de chaque côté de la caisse du foyer à l’aide de 2 vis par côté; les supports dépassent l’avant de la caisse d’environ 3/8 de pouce (10mm).

Plaque de fi nition 582CPB ou 583CPB (exigée)Dimensions

30” (762 mm)

33” (

838

mm

)

Plaque de fi nition 583CPB

26” (660 mm)

31” (

787

mm

)

Plaque de fi nition 582CPB

Page 12: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

12

3. Fixez la plaque de fi nition aux supports de montage à l’aide de 6 vis autotaraudeuses.

4. Si les crochets ne sont pas installés, installez-les aux coins supérieurs de la devanture de fonte. Accrochez la devanture à l’appareil.

Page 13: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

13

Entretien

Pour nettoyer le pare-étincelles et la devanture de fonte, utilisez une brosse souple.Si le pare-étincelles est endommagé, il doit être remplacé par le pare-étincelles conçu par le manu-facturier pour cet appareil.Pour nettoyer la vitre de la fenêtre du foyer, consultez le guide du consommateur fourni avec le foyer. NE PAS nettoyer la vitre avec un produit à base d’ammoniaque. Enlèvement de la devantureDécrochez la devanture en la tenant sous la parure ornementale du haut. NE PAS soulever la devanture par son bord supérieur.Toujours remettre la fenêtre et la devanture munie du pare-étincelles en place et les fi xer solidement avant d’allumer le foyer.

AVERTISSEMENTNE TOUCHEZ PAS LE NE TOUCHEZ PAS LE PARE-ÉTINCELLESPARE-ÉTINCELLES, LA , LA DEVANTURE OU LA FENÊTRE LORSQU’ILS DEVANTURE OU LA FENÊTRE LORSQU’ILS SONT CHAUDS! SONT CHAUDS! Laissez le foyer refroidir avant de Laissez le foyer refroidir avant de le nettoyer.le nettoyer.

AVERTISSEMENTPOUR RAISONS DE SÉCURITÉ, assurez-vous POUR RAISONS DE SÉCURITÉ, assurez-vous que le pare-étincelles soit réinstallé sur le foyer que le pare-étincelles soit réinstallé sur le foyer après l’entretien.après l’entretien.

Page 14: 536CXBI - 4005304-04 536CXBI President Front Insert E-F · 1 Plaque de fi nition 2 Supports de montage 4 Vis M4 x 12 mm 6 Vis no 8 x 3/8 Les deux de plaques de fi nition off ertes

14

Liste de pièces

1

11

8

7

109

62

34

5

# Description Numéro Numéro alternatif

1 Devanture complète 568979 040A5192 Boulon, charnière du garde-cendres 568999 420K5583 Garde-cendres 568989 540K048AZ4 Rondelle 532529 100B8105 Aimant 569009 020A0856 Devanture de fonte 568929 050A255AZ7 Crochet, côté droit 568949 330A9238 Crochet, côté gauche 568939 330A9229 Dessus de fonte 568969 550K065AZ

10 Défl ecteur d’air 569019 340B252AZ11 Pare-étincelles 4003359 400335912 Plaque de fi nition 26” sur 31” 4005203AZ13 Plaque de fi nition 30” sur 33” 4005198AZ14 Supports de montage (2) avec chaque plaque 4005199

Conçue et fabriquée par / pourMiles Industries Ltd.

190 – 2255 Dollarton Highway, North Vancouver, BC, CANADA V7H 3B1Tél. 604-984-3496 Téléc. 604-984-0246

www.foyervalor.com

Parce que nous favorisons une politique de développement continu, certains détails de la présente publication peuvent varier.

14

12 (582CPB)

13 (583CPB)