5. MMS System - Vogel · .5 Modular Protection System Identification and access control Protect...

9
192 MMS System 2 .5

Transcript of 5. MMS System - Vogel · .5 Modular Protection System Identification and access control Protect...

Page 1: 5. MMS System - Vogel · .5 Modular Protection System Identification and access control Protect your safety cabinets against unauthorised access, with the Modular Protection System

192

MMS System2.5

Page 2: 5. MMS System - Vogel · .5 Modular Protection System Identification and access control Protect your safety cabinets against unauthorised access, with the Modular Protection System

193

MediaManagement system the modern handling of hazardous substances

2.5

Type 90

Page 3: 5. MMS System - Vogel · .5 Modular Protection System Identification and access control Protect your safety cabinets against unauthorised access, with the Modular Protection System

[email protected]

www.dueperthal.comDUEPERTHAL SICHERHEITSTECHNIK GMBH & CO. KG Frankenstrasse 3, 63791 Karlstein, Germany

Phone + 49 6188 9139-0 Fax + 49 6188 9139-121 194

2.5

The MediaManagement System (MMS) is a diverse, multifunctional and high-quality solution for modern laboratory management. The large benefit for laboratory operators and managers is already considered to point the way ahead. The modular system has a programmable control terminal and a large number of functional applications for intelligent use of resources and work equipment.

The solution for users and laboratory managers.

A certified system solution

futurehandling

Page 4: 5. MMS System - Vogel · .5 Modular Protection System Identification and access control Protect your safety cabinets against unauthorised access, with the Modular Protection System

[email protected]

www.dueperthal.comDUEPERTHAL SICHERHEITSTECHNIK GMBH & CO. KG Frankenstrasse 3, 63791 Karlstein, Germany

Phone + 49 6188 9139-0 Fax + 49 6188 9139-121 195

2.5

The solution for users and laboratory managers.

MMS offer you:

Modern laboratory management:lThe paperless organisation is supported, the internal work flow refined in data terms.lMedia consumption can be continuously evaluated and performance indicators are available for cost accounting (controlling).lContinuous analysis of the media consumption enables optimisation of the internal and external logistics areas and helps to save surplus media.lHighly compatible with existing data management systems, integrated interfaces reduce operating costs.

Optimisation of work safety:lControl of the removal or filling of containers by means of diverse safety modules.lOptimises safety procedures in practice, ideal as a risk analysis module.lAuthorised qualified personnel only has access to the hazardous substances, the risk of misuse is reduced.lDocumentation of the hazardous substances used according to the industrial safety regulations, hazardous substances regulations and occupational safety.lClear traceability of the work operations via data storage including analysis option.

handling

working safety

The safe control centre ...

Page 5: 5. MMS System - Vogel · .5 Modular Protection System Identification and access control Protect your safety cabinets against unauthorised access, with the Modular Protection System

[email protected]

www.dueperthal.comDUEPERTHAL SICHERHEITSTECHNIK GMBH & CO. KG Frankenstrasse 3, 63791 Karlstein, Germany

Phone + 49 6188 9139-0 Fax + 49 6188 9139-121 196

2.5

A certified system solution

the solution for users and laboratory managers

The identification module enables authorised persons only to receive access to the relevant hazardous substances. With active storage, the media release always takes place via the identification. Input via programmable PIN codes is provided for identification. Identification via transponder keys or biometric analysers is possible on request.

Exhaust air monitor module for monitoring and alarm signalling. The ventilation of safety cabinets approved for active storage must run constantly. The exhaust volume flow must be monitored and an alarm emitted in the event of failure. This requirement can be fulfilled with the exhaust air monitor module, i.e. an alarm is triggered if the air stream drops and, e.g. a signal is sent to the central control.

Metering module for precise filling. With the metering module, metered filling of the smallest quantities of media from large containers becomes a simple, safe process The ideal add-on to a COMPLEX line drum sta-tion not only provides metering, but also the ability to continuously analyse consumption and remaining quantity data.

Level indicator module, warns of overfilling of containers. With the level indicator module, the risk of overfilling is substantially minimised and safety increases for users and the environment. The level indicator module completes the perfect DISPOSAL line solution. Combining the DISPOSAL line and COMPLEX line provides ideal preconditions for safe and easy media management.

Door opening module. Door opening can be activated using the keypad. After confirming the input command, a warning signal informs the user that the automatic door opening is starting. The pneumatic control from DUEPERTHAL is free of electrical and electronic components and is therefore the ideal solution in and around potentially explosive atmospheres.

Door locking module. Used in conjunction with identification, the door locking module not only enables media release but also locking and unlocking of the doors. Authorisation can therefore be extended to access to the safety cabinets.

Media Management System with programmable control terminal and a large number of functional modules for maximum working safety. A control terminal can be used for several safety cabinets and equipped with all kinds of different modules.

Page 6: 5. MMS System - Vogel · .5 Modular Protection System Identification and access control Protect your safety cabinets against unauthorised access, with the Modular Protection System

[email protected]

www.dueperthal.comDUEPERTHAL SICHERHEITSTECHNIK GMBH & CO. KG Frankenstrasse 3, 63791 Karlstein, Germany

Phone + 49 6188 9139-0 Fax + 49 6188 9139-121 197

MMS module

2.5 in detail

the solution for users and laboratory managers

Print-out or media ID label

Signal to control unit/center

Data transmission - liquid supplier

Data interface - external costing

Downloading File: From MMSystem to my computer

Page 7: 5. MMS System - Vogel · .5 Modular Protection System Identification and access control Protect your safety cabinets against unauthorised access, with the Modular Protection System

[email protected]

www.dueperthal.comDUEPERTHAL SICHERHEITSTECHNIK GMBH & CO. KG Frankenstrasse 3, 63791 Karlstein, Germany

Phone + 49 6188 9139-0 Fax + 49 6188 9139-121 198

2.5

handling

future

capabilit iesDUEPERTHAL safety cabinets in use with MediaManagement system.

Page 8: 5. MMS System - Vogel · .5 Modular Protection System Identification and access control Protect your safety cabinets against unauthorised access, with the Modular Protection System

[email protected]

www.dueperthal.comDUEPERTHAL SICHERHEITSTECHNIK GMBH & CO. KG Frankenstrasse 3, 63791 Karlstein, Germany

Phone + 49 6188 9139-0 Fax + 49 6188 9139-121 199

2.5

C H E C K L I S T

2. Safety cabinets

The following DUEPERTHAL safety cabinets should be activated with the MMS control terminal:

Safety cabinet 1 - model:

Safety cabinet 2 - model:

Safety cabinet 3 - model:

Safety cabinet 4 - model:

3.5 Door opening module

The door opening module enables activation of automatic door opening and closing including the option of real time control

Door opening module requested? yes no

for cabinet: 1 2 3 4

3.6 Door locking module

By using the door locking module in combination with the identification module, you authorise for which user the cabinet doors are unlocked.

Door locking module requested? yes no

for cabinet: 1 2 3 4

3.7 Data software DBS

For analysis of the MMS data at the PC. The data is transferred via the USB stick.

Data software requested? yes no

date | signature | stamp

1. Your data

Name: Phone:

Company: Fax:

Street/P.O.Box: E-mail:

Postcode/City:

3.1 Modul for identification

With the identification module you utilise the option of documenting who accessed the contents of the safety cabinet (media) at what time.

Idenfification module requested? yes no

for cabinet: 1 2 3 4

3.2 Exhaust air monitor module

With the exhaust air monitor module you can control the ventilation for each specific use and optimise energy consumption.

Exhaust air monitor module requested? yes no

for cabinet: 1 2 3 4

3.3 Metering module

With the metering module you can preselect the smallest quantities (ml) through to large quantities (l) and then precisely fill.

Metering module requested? yes no

for cabinet: 1 2 3 4

3.4 Fill level module

The level indicator module warns of overfilling and reduces the risk of environmental contamination.

Fill level module requested? yes no

for cabinet: 1 2 3 4

3. Selection of the functions:

Select the modules to match your control terminal for functional application and intelligent use of resources and work equipment.

Page 9: 5. MMS System - Vogel · .5 Modular Protection System Identification and access control Protect your safety cabinets against unauthorised access, with the Modular Protection System

[email protected]

www.dueperthal.comDUEPERTHAL SICHERHEITSTECHNIK GMBH & CO. KG Frankenstrasse 3, 63791 Karlstein, Germany

Phone + 49 6188 9139-0 Fax + 49 6188 9139-121 200

2.5

ModularProtection System

Identification and access control

Protect your safety cabinets against unauthorised access, with the Modular Protection System (MPS). The system enables you to implement modern physical access control to resources and hazardous substances.

Note!If you have any questions or wish to place an order for the MPS system, we require the model number of the DUEPERTHAL safety cabinet selected by you.

A certified system solution

The intelligent access control.

The identification enables authorised persons only to receive access to the relevant hazardous substances. Input via programmable PIN codes is provided for identification. Used in combina-tion with the identification module, it enables the doors to be locked and unlocked. Authorisation can therefore be extended to access to the safety cabinets.The MPS is an important module to help you fulfil the ever-increasing risk analysis requirements with respect to access control. For example, use in practice can mean that work instructions for safe and controlled handling of dangerous substances can be simplified, e.g. TRGS 526.

Functional application of the MPS also includes the option of equipping safety cabinets with the new one-hand door technology ONE with automa-tic door closing. This can be enabled via PIN input and other identifiers, e.g. transponders, biometric analysers, etc.

2.5.2 Modular Protection System

Modular Protection System with:

Identification and access control Ref. no.

- MPS system 1 50-30000-920

Identification, access control and automatic door closing

- MPS system 2 50-30000-921

futurehandling