433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective...

48
R Installation and service of this fireplace should be performed by qualified personnel. Hearth & Home Technologies recommends NFI certified profes- sionals, or technicians supervised by an NFI certified professional. EPA CERTIFIED WOODBURNING FIREPLACE Fire Risk. WARNING For use with solid wood fuel only. Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide). O-T L Tested and Listed by Portland Oregon USA OMNI-Test Laboratories, Inc. C US Model(s): Installion Manual Installation and Fireplace Setup WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace. Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. Keep clothing, furniture, draperies and other flammable materials away. INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference. 7100FP-BK-B 7100FP-GD-B 7100FP-NL-B NOTICE: DO NOT discard this manual! DO NOT store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance. DO NOT overfire. Overfiring will void your warranty. • Comply with all minimum clearances to com- bustibles as specified. Failure to comply may cause house fire. WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death. Pour demander un exemplaire en français de ce Manuel du propriétaire, visitez www. heatnglo.com/translations. 1 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Transcript of 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective...

Page 1: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

R

Installationandserviceofthisfireplaceshouldbeperformedbyqualifiedpersonnel.Hearth&HomeTechnologiesrecommendsNFIcertifiedprofes-sionals,ortechnicianssupervisedbyanNFIcertifiedprofessional.

EPA CERTIFIED WOODBURNING FIREPLACE

Fire Risk.

WARNING

For use with solid wood fuel only.Other fuels may overfi re and generate poisonous gases (i.e. carbon monoxide).

O-T LTested and Listed by

PortlandOregon USA

OMNI-Test Laboratories, Inc.C US

Model(s):

Installion ManualInstallation and Fireplace Setup

WARNINGHOT SURFACES! GlassandothersurfacesarehotduringoperationANDcooldown.

Hot glass will cause burns.• DO NOTtouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway

• CAREFULLY SUPERVISE children in same room asfireplace.

• Alertchildrenandadultstohazardsofhightemperatures.

High temperatures may ignite clothing or other fl ammable materials.• Keep clothing, furniture, draperies and other flammablematerialsaway.

INSTALLER: Leave this manual with party responsible for use and operation.OWNER: Retain this manual for future reference.

7100FP-BK-B7100FP-GD-B7100FP-NL-B

NOTICE: DO NOT discard this manual!

• DO NOTstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthisoranyotherappliance.

• DO NOToverfire.Overfiringwillvoidyourwarranty.

• Complywithallminimumclearancestocom-bustiblesasspecified.Failuretocomplymaycausehousefire.

WARNING: If the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, personal injury, or death.

PourdemanderunexemplaireenfrançaisdeceManueldupropriétaire,visitezwww.heatnglo.com/translations.

1Quadra-Fire•7100FP•433-3610InstallationManual•RevF•3/25/14

Page 2: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

Safety Alert Key:• DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury.• WARNING!Indicatesahazardoussituationwhich,ifnotavoidedcouldresultindeathorseriousinjury.• CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderateinjury.• NOTICE:Indicatespracticeswhichmaycausedamagetothefireplaceortoproperty.

Table of Contents1 Product Specific & Important Safety Information

A.FireplaceCertification 4B.GlassSpecifications 4C.Non-CombustibleMaterials 4D.CombustibleMaterials 4E.ElectricalCodes 5

2 Getting Started A.TypicalFireplaceSystem 6B.DesignandInstallationConsiderations 7

1.SelectingFireplaceLocations 72.LocatingFireplace&Chimney 8

C.ToolsandSuppliesNeeded 9D.InspectFireplaceandComponents 9E.FireplaceSystemRequirements 9

3 Framing and Clearances A.FireplaceDimensions 10B.Clearances 11

1.MinimumClearancestoCombustibles 12C.ConstructtheChase 13D.FrametheFireplace 14E.SecureandLeveltheFireplace 14F. ProtectiveMetalHearthStrips 15G.FacingMaterial 15H.OutsideAirKit 16I. AuxiliaryConvectionAirSystem 18J. HeatZoneKit(Optional) 20

4 Electrical Wiring 5 Chimney and Termination Requirements

A.ChimneyRequirements 24B.Offsets/Returns 25C.TerminationRequirements 26

6 Chimney Installation A.TypicalChimneySystem 27B.AssembleChimneySections 28C.InstallChimneyAirkit(CAK4A) 28D.SecureOffset/Return 30E. InstallCeilingFirestops 30F. InstallAtticInsulationShield 31G.RoofPenetration 32H.ManufacturedHomeInstallation 32I. InstallChase/ChaseTop 33J. TerminationCapRequirements 34K. InstallTerminationCap 34

7 Finishing A.Template 36B FinishtheWall 36

1.Stone,BrickFinish 362.Tile,Granite,MarbleFinish 36

C.MantelandWallProjections 37D.FinishingtheHearthExtension 37E.Non-CombustibleSealantMaterial 39

8 Fireplace Setup A.FirebrickPlacement 40B.BaffleandBlanketPlacement 41C.InstallFascia(Fronts) 41

9 Reference Materials A.ChimneyComponents 42B.Accessories 46MESH-HHTFirescreen 46

2 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 3: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

Customer:Lot/Address

Model (circle one): 7100FP-BK-B 7100FP-GD-B7100FP-NL-B

Fireplace Install YES IF NO, WHY?Verifiedthatthechaseisinsulatedandsealed.(Pg.13)Requirednon-combustibleboardisinstalled.(Pg.15)Verifiedclearancestocombustibles.(Pg.11)Fireplaceisleveledandsecured.(Pg.14)Hearthextensionsize/heightdecided.(Pg.14&37)Outsideairkitinstalled.(Pg.16)OptionalHeatZonehasbeeninstalledbyaqualifiedservicetechnician.(Pg.18)

Chimney Section 5 (Pg. 24)Chimneyconfigurationcomplieswithdiagrams.Chimneyinstalled,lockedandsecuredinplacewithproperclearance.

Roofflashinginstalledandsealed.Terminationsinstalledandsealed.

Electrical Section 4 (Pg. 23)Switchwiresproperlyinstalled.

Finishing Section 7 (Pg. 36)Combustible materials not installed in non-combustible areas

Dealer/Distributor Phone #Serial #:

WARNING! Risk of Fire or Explosion! Failure to install fireplace acording to these instructions can lead to a fire or explosion.

Firestopsinstalled.Chimneyairkitinstalled.

Atticinsulationshieldsinstalled.

ATTENTION INSTALLER:Follow this Standard Work Checklist

Thisstandardworkchecklististobeusedbytheinstallerinconjuctionwith,notinsteadof,theinstructionscontainedinthis installation manual.

Date Installed:Location of Fireplace:Installer:

Combustible materials not installed in non-combustible areas.Verifiedallclearancesmeetinstallationmanualrequirements.Mantelsandwallprojectionscomplywithinstallationmanualrequirements.Protectivehearthstripsandhearthextensioninstalledpermanualrequirements.

Fireplace Setup Section 8 (Pg. 40)Allpackagingandprotectivematerialsremoved.Firebrick,baffleandceramicblanketinstalledcorrectly.Faciaanddoorsproperlyinstalled.

Allpackagingmaterialsareremovedfrominside/underthefireplace.

Hearth & Home Technologies recommends the following:•Photographingtheinstallationandcopyingthischecklistforyourfile.•Thatthischecklistremainvisibleatalltimesonthefireplaceuntiltheinstallationiscomplete.

Commentscommunicatedtopartyresponsible

Part#4017-254•RevB•01/29/13

__________________________by______________________on_________(Builder/Gen.Contractor)(Installer)(Date)

Comments:Furtherdescriptionoftheissues,whoisresponsible(Installer/Builder/OtherTrades,etc.)andcorrectiveactionneeded:_________________________________________________________________________________________________

Manualbagandallofitscontentsareremovedfrominside/underthefireplaceandgiventothepartyresponsibleforuseandoperation.

________________________________________________________________________________________________________________________________________________________________________________________________________________

3Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 4: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

1 Product Specific & Important Safety Information

A. Fireplace CertificationThisfireplacesystemhasbeentestedandlistedinac-cordancewithUL127andULC-S610-M87and(UM)84-HUDstandardsforinstallationandoperationintheUnitedStatesandCanadaasdescribedinthismanual.

Checkwithyourlocalbuildingcodeagencybeforeyoubeginyourinstallationtoensurecompliancewithlocalcodes,includingtheneedforpermitsandfollow-upin-spections.BesurelocalbuildingcodesdonotsupersedeULspecificationsandalwaysobtainabuildingpermitsothatinsuranceprotectionbenefitscannotbeunexpectedlycancelled.

QuadrafireisaregisteredtrademarkofHearth&HomeTechnologies.

C. Non-Combustible Materials• Materialswhichwillnot igniteandburn,composedof

anycombinationofthefollowing:- Steel - Iron- Brick - Tile- Concrete - Slate- Glass - Plasters

• MaterialsreportedaspassingASTM E 136, Standard Test Method for Behavior of Metals, in a Vertical Tube Furnace at 750° C

B. Glass SpecificationsThisfireplaceisequippedwith5mmceramicglass.Re-placeglassonlywith5mmceramicglass.Pleasecontactyourdealerforreplacementglass.

NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the UL127, (UM) 84-HUD and NFPA211 in the U.S.A. and the ULC 610-M87 and CAN/CSA-B365 Installation Codes in Canada.

WARNING! Risk of Fire! Hearth & Home Technologies disclaims any responsibility for, and the warranty and agen-cy listing will be voided by the following actions.DO NOT:• installoroperatedamagedfireplace• modifyfireplace• install other than as instructed by Hearth & Home

Technologies• operate the fireplace without fully assembling all

components• overfire• installanygaslogset• installanycomponentnotapprovedbyHearth&Home

Technologies• installpartsorcomponentsnotListedorapprovedImproper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualifiedinstaller, service agency or your dealer.

Model: 7100FPEPACertified WoodburningFireplace

Laboratory: OMNITestLaboratories,Inc.Report No: 061-S-41-2Type: WoodFireplaceStandard: UL127andULC-S610-M87and

(UM)84-HUD,ManufacturedHomeApproved.

EPA# and Original Date: #5714-1-03

EPA Certified: 3.1gramsperhour

Efficiency: upto77%

BTU Output with EPA test fuel: 58,000/hr.

with Cord Wood: 90,000/hr.

Heating Capacity: upto3,500sqft

Chimney Size: 8inches

HHT SL300Series

DuraVent DuraPlus

Max Wood Length: 24inches

Fuel: CordWood

Shipping Weight: 670lbs

Firebox Size 3.4cubicfeet WARNING! Risk of Fire! Hearth & Home Technologies is not responsible for

discoloration, cracking or other material failures of finishingmaterialsduetoheatexposureorsmoke.

• Choosefinishingmaterialscarefully.

4 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 5: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

E. Electrical Codes

NOTICE: This fireplacemust be electrically wired andgrounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA C22.1.

• A110-120VACcircuitforthisproductmustbeprotectedwith ground-fault circuit-interrupter protection, incompliancewiththeapplicableelectricalcodes,whenitisinstalledindamplocations.

WARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury or property dam-age.

D. Combustible Materials• Materialsmadeoforsurfacedwithanyofthefollowing

materials:- Wood - Compressedpaper- Plantfibers - Plastic- Plywood/OSB - Sheetrock(drywall)

• Anymaterialthatcanigniteandburn;flameproofedornot,plasteredorun-plastered

5Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 6: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

2 Getting Started

Termination Cap

Chimney penetrates roof preferably without affectingroof rafters

Offset/Return (with hanger straps)

Attic insulation shield must be used to keep insulation away from chimney if attic is insulated

Storm Collar

Framing headed off in ceiling joists

Mantel

Chimney system

Combustible framing/headeron top of V-shaped standoffs (spacers)

Non-combustible material

Hearth extension

Non-combustibleroof flashing maintainsminimum clearancearound chimney

Additional lateralsupport for chimneyabove roof (or enclosedin chase) if needed

Enclosed space aboveand around fireplace

Ceiling firestopon floor of attic

Support strapson rafter supportschimney (not shown)

Outsidecombustion air

Outsidecombustion air

Chimney Air Kit (CAK-4A) (not shown) must be used with SL300 chimney

Protective metalhearth strip(s)

A. Typical Fireplace System

Figure 2.1 Typical Fireplace System

6 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 7: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

D

CA

E

F

AH

GB

A

B

B

AI

In an exterior chase or projecting into a garage

Across a corner

Along a wall

As a room divider

24 in. (610mm)

24 in. (610mm)

24 in. (610mm)

48 in. (1219mm)

24 in. (610mm)

I

A

Figure 2.2 Fireplace Locations

NOTICE:• Illustrationsandphotosreflecttypicalinstallationsand

are FOR DESIGN PURPOSES ONLY.• Illustrations/diagramsarenotdrawntoscale.• Actualinstallation/appearancemayvaryduetoindividual

design preference.• Hearth&HomeTechnologiesreservestherighttoalter

its products.

NOTICE: In addition to these framing dimensions, also reference the following section:

• Clearances (Section 3).

NOTICE: A minimum 1/2 in. air clearance at the back and a minimum 1 in. air clearance to the sides of the fireplaceassemblymustbemaintained.Chimney sections at any level require a 2 in. mini-mum air space clearance between the framing and chimney sections.

B. Design and Installation Considerations

NOTICE: Check building codes prior to installation.

• InstallationMUSTcomplywithlocal,regional,stateandnationalcodesandregulations.

• Consult insurancecarrier, localbuildinginspector,fireofficialsorauthoritieshavingjurisdictionoverrestrictions,installationinspectionandpermits.

1. Selecting Fireplace LocationsThisfireplacemaybeusedasaroomdivider,installedalongawall,acrossacornerorusedinanexteriorchase.SeeFigure2.2.

Locatingthefireplaceinabasement,nearfrequentlyopeneddoors,centralheatoutletsorreturns,orotherlocationsofconsiderableairmovementcanaffecttheperformance.

Outsideairmustbeusedforcombustion.The7100FPcomesequippedwithanoutsideairinlettofeedcombus-tionairfromoutsidethehome,alongwithanoutsideairterminationcap;therigidmetalductisrequiredbutnotsupplied.Considerationshouldbegiventothesefactorsbeforedecidingonalocation.

Model#7100FP A B C D E F G H I

(Dimensionsfor finishedwalls)

in. 42-1/4 16 89-1/2 63-5/16 22-7/16 44-3/4 14-1/16 55-15/16 50-7/8

mm 1063 406 2273 1608 570 1137 357 1421 1292

7Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 8: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

2. Locating Fireplace & Chimney

Locationofthefireplaceandchimneywillaffectperfor-mance.

• Installwithinthewarmairspaceenclosedbythebuildingenvelope.Thishelpstoproducemoredraft,especiallyduringlightinganddie-downofthefire.

• Penetratethehighestpartof theroof.Thisminimizestheeffectsofwindloading.

• Locate termination cap away from trees, adjacentstructures,unevenrooflinesandotherobstructions.

• Minimizetheuseofchimneyoffsets.• Considerthefireplacelocationrelativetofloorandceiling

andatticjoists.• Takeintoconsiderationtheterminationrequirementsin

Sections5and6.

Marginal Location:• Below peak

Location NOT recommended:• Not the highest point of the roof• Wind loading possible

Multi-level Roofs

Windward

Leeward

Recommended Location:• Above peak

Recommended:• Insulated exterior chase

in cooler climates

Recommended Location:• Above peak• Inside heated space

Location NOT recommended:• Too close to tree• Below adjacent structure• Lower roof line• Avoid outside wall

Marginal Location:• Wind loading possible

Figure 2.3 Recommended Chimney Locations

• Installtheoutsideairkitwiththeintakefacingprevailingwindsduringtheheatingseason.

• Ensure adequate outdoor air for all combustionappliancesandexhaustequipment.

• Ensurefurnaceandairconditioningreturnventsarenotlocatedintheimmediatevicinityofthefireplace.

• Avoid installingthefireplaceneardoors,walkwaysorsmallisolatedspaces.

• Recessedlightingshouldbea“sealedcan”design.• Attichatchesweatherstrippedorsealed.• Atticmountedductworkandairhandlerjointsandseams

tapedorsealed.

8 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 9: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

C. Tools and Supplies NeededBeforebeginningtheinstallationbesurethefollowingtoolsandbuildingsuppliesareavailable:

Reciprocatingsaw Framingmaterial

Pliers Non-combustiblesealant

Hammer Gloves

Phillipsscrewdriver Framingsquare

Flatbladescrewdriver Electricdrillandbits

Plumbline Safetyglasses

Level Tapemeasure

1/2-3/4in.length,#6or#8self-drillingscrews

Misc.screwsandnails

D. Inspect Fireplace and Components

WARNING! Risk of Fire and/or Explosion! Damaged parts could impair safe operation. DO NOT install dam-aged,incompleteorsubstitutecomponents.Keepfire-place dry.

• Removefireplaceandcomponentsfrompackagingandinspectfordamage.

• Vent system components and doors are shipped inseparatepackages.

• Reporttoyourdealeranypartsdamagedinshipment.• Read all the instructions before starting the

installation. Follow these instructions carefully during the installation to ensure maximum safety and benefit.

E. Fireplace System RequirementsTheQuadra-Firefireplacesystemrequirementsconsistofthefollowing:

• Fireplace- Firebrick(includedwithfireplace)- Door(includedwithfireplace)- Non-combustible facingmaterial (included with

fireplace)- HearthExtension

• OutsideAir System (hood and collars includedwithfireplace)

• Fascia• ChimneySystem

- Chimneyairkit(includedwithfireplace,requiredwithSL300serieschimney)

- AtticInsulationShield(includedwithfireplace)- Chimneyterminationcap

• Non-combustiblefinishmaterial

Optionalcomponentsinclude:• Firescreen• LintelBar• HeatZoneKit

9Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 10: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

3 Framing and Clearances

A. Fireplace Dimensions

CL

Blower Electric Access(right side of fireplace)

3-1/2 in.(89 mm)

32-1/2 in.(826 mm)

38 in.(965 mm)

40 in.(1016 mm)

42-5/16 in.(1075 mm)

45-13/16 in.(1148 mm)

23-7/16 in.(595 mm)

13-3/16 in.(335 mm)

10-13/16 in.(259 mm)

4-5/16 in.(109 mm)

6 in.(152 mm)

1 in.(25 mm)

13-3/4 in.(349 mm)

9-7/16 in.(240 mm)

43 in.(1092 mm)

Figure 3.1 Fireplace Dimensions

10 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 11: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

B. ClearancesWARNING! Risk of Fire!

YoumustcomplywithallminimumairspaceclearancestocombustiblesasspecifiedinFigure3.2.DO NOT pack required airspaceswithinsulationorothermaterials.Framingorfinishingmaterialusedonthefrontof,orinfrontof,thefireplacecloser than the minimums listed must be constucted entirely of non-combustible materials (i.e., steel studs, concrete board, etc.).Failuretocomplymaycausefire.

Figure 3.2 Clearances to Combustible Materials

(ceiling)

(roof)

(ceiling)

2 in. (51 mm) min.

Attic Insulation

Shield

Ceiling Firestop(attic)

Storm Collar

Roof Flashing

2 in. min.(51 mm)

2 in. (51 mm) min.

2 in. (51 mm) min.

Ceiling Firestop Offset/Return with hanger straps

2 in.(51 mm)

min.

2 in. (51 mm) min.

Must have 2 in. (51 mm)minimum clearance

to header

Electrical wires must be 3-1/2: (89mm) from top

0 in. to levelof standoffs

1 in. (25mm) to side of appliance

1/2 in. (13 mm) to backof appliance

0 in.to floor

36 in. (914 mm) standoffs to ceiling

Chimney Air Kit required with SL chimney

11Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 12: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

1. Minimum Clearances to Combustibles

Position combustible/ non-combustible mantel60 in. (1524 mm) from base of fireplace

12 in.(305 mm)

46-1/4 in.(1175 mm)

24 in.(610 mm)

2 in.(51 mm)

48-1/4 in.(1226 mm)

42-1/4 in.(1073 mm)

The finished cavity depth must be no less than 24 in. (610 mm) from the finished backwall to the outside of front wall framing.

Figure 3.3 Framing the Fireplace

WITHIN ENCLOSURE AREAFireplacetobackwall 1in.(25mm)Fireplacetosidewall 1in.(25mm)Ductbootstoframing 0in.(0mm)Topstandoffstoheader 0in.(0mm)Dooropeningtosidewall 22-7/8in.(581mm)

EXPOSED SURFACESFaceplatetosidewall 16in.(406mm)Heatzoneairgrillstoceiling 12in.(305mm)

MANTELNon-combustiblemantel(Non-combustibleframingmaterialsabovethefireplacetoceiling) 46in.(1168mm)Combustiblemantel(Combustibleframingmaterialsabovethefireplacetoceiling) 60in.(1524mm)Maximummanteldepth 12in.(305mm)

12 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 13: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

C. Construct the ChaseAchaseisaverticalboxlikestructurebuilttoenclosethefireplaceand/oritsventsystem.Verticalchimneysthatrunontheoutsideofabuildingmustbeinstalledinsideachase.

Incoldclimates,Hearth&HomeTechnologiesrecom-mendsthatthechasebewellinsulatedusingbatttypeinsulationbetweenthejoists.

Constructionofthechasemayvarywiththetypeofbuild-ing.Theseinstructionsarenotsubstitutesfortherequire-mentsoflocalbuildingcodes.LocalbuildingcodesMUSTbechecked.

Chasesshouldbeconstructedinthemannerofalloutsidewallsofthehometopreventcoldairdraftingproblems.Thechaseshouldnotbreaktheoutsidebuildingenvelopeinanymanner.Allouterwallsneedtobeinsulated.

Buildingcodesrequirefalseceilingandceilingfirestops/atticshieldsateachfloorofthechaseorevery10ft(3048mm)ofclearspacetocontrolspreadoffire.

Walls,ceiling,baseplateandcantileverflooratthefirstlevelofthechaseshouldbeinsulated(seeFigure3.4.)Vaporandairinfiltrationbarriersshouldbeinstalledinthechaseasperregionalcodesfortherestofthehome.Ad-ditionally,Hearth&HomeTechnologiesrecommendsthattheinsidesurfacesbedrywalledandtaped(ortheuseofanequivalentmethod)formaximumairtightness.

Holesandotheropeningsshouldbecaulkedwithhightemperaturecaulkorstuffedwithunfacedfiberglassinsulation.

Ceiling Firestop

Metal Chase Top

Round Termination Cap

False Ceiling

Insulation in the outside walls of the chase

Attic Insulation

Shield

Chimney

Ceiling Firestop

Tabs

False Ceiling False Ceiling Insulation Insulation

Storm Collar

Figure 3.4 Chase Assembly

1 2 3

All outside walls should be insulated.

Figure 3.5 Chase Constructions

1. Fireplaceandchimneyenclosedinanexteriorchase. 2. Chimneyoffsetthroughexteriorwallandenclosedinchase. 3. Chaseconstructedonroof.

• Thechaseisconstructedusingframingmaterialsmuchthesameasthewallsinyourhome.Avarietyofsidingmaterialsmaybeused includingbrick, stone, veneerbrick,orstandardsidingmaterials.

• In constructing the chase, several factorsmust beconsidered:- Maintain a 2 in. (51mm) air space around the

chimney.- The chase top must be constructed of non-

combustiblematerial.- Incoldclimates,afirestopspacerandatticinsulation

shieldshouldbeinstalledinaninsulatedfalseceilingat the 8 ft. (2438mm) level above the fireplaceassembly.Thisreducesheatlossthroughthechase.

- Incoldclimates, thewallsof thechaseshouldbeinsulatedtothelevelofthefalseceilingasshowninFigure3.4.Thiswillhelpreduceheatlossfromthehomearoundthefireplace.

ThreeexamplesofchaseapplicationsareshowninFig-ure3.5.

WARNING! You must install false ceilings and ceil-ing firestops at each floor of the chase or every 10 ft (3.05 m) to control spread of fire.

WARNING! Risk of Fire! DO NOT sealareabetweenfirestop opening and chimney pipe except where they enter the attic or leave the warm air envelope of the home (use 600° F sealant).

WARNING! Risk of Fire! You must maintain a minimum 2 in. (51 mm) air space clearance to insulation and other materials surrounding the chimney system.• Insulationandothermaterialsmustbefirmlysecuredto

prevent accidental contact with chimney system.• Thechasemustbeproperlyblockedtopreventblown

insulation or other combustibles from entering and makingcontactwithfireplaceorchimney.

• Failuretopreventcontactbetweeninsulationorothermaterials and chimney system may cause overheating andfire.

13Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 14: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

D. Frame the Fireplace

NOTICE: Hearth extension designmust be determinedbeforeinstallationoffireplace.

Ifthefireplaceisplacedonthefloorthemaximumheightofafinishedraisedhearthis5-3/4”,ifyouwantahigherraisedhearththefireplacemustbeplacedonaplatform.

NOTICE: Wiring for fans must be done before framed enclosure is completed. If using a Heat Zone Kit, it also must be installed before enclosure is complete.The7100FPFireplacewillfitaframedopeningheightof46-1/4in.(1174mm)talland42-1/4in.(1073mm)wide.

WARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles. DO NOT pack required air spaces with insulation or other materi-als.

WARNING! Risk of Fire! Comply with all minimum clear-ancesspecified.• Aminimum 1/2 in. (13mm) air clearancemust be

maintained at the back and 1 in. (25 mm) to the sides ofthefireplaceassembly.

• Chimneysectionsatanylevelrequirea2in.(51mm)minimum air space clearance between the framing and chimney section.

Figure3.3showsatypicalframing(using2x4lumber)ofthefireplace,assumingcombustiblematerialsareused.Allrequiredclearancestocombustiblesaroundthefireplacemustbeadheredto.SeeFigure3.2.Anyframingacrossthetopofthefireplacemustbeabovethelevelofthetopstandoffs.(Norecessabovestandoffs.)

The finished cavity depth must be no less than 24 in.(610mm)fromthefinishedbackwalltotheoutsideoffrontwallframing.Framingmustextendstraightupallthewaytotheceiling.

CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp.

WARNING! Risk of Fire! Prevent contact with sagging, loose insulation. • DO NOT install against vapor barriers or exposed

insulation.• Secureinsulationandvaporbarriers.• Provideminimumairspaceclearancesatthesidesand

backofthefireplaceassemblyasoutlinedinSection3.

E. Secure and Level the FireplaceThisfireplacemaybeplacedoneitheracombustibleornoncombustiblecontinuousflatsurface.Followthein-structionsforframinginSection3.Slidethefireplaceintoposition.Besuretoprovidetheminimum1in.airclear-anceatthesidesand1/2in.atthebackofthefireplace.

Thefireplaceshouldbepositionedsothefaceofthenon-combustiblematerialonthefireplacewillbeflushwiththefaceofthedrywallonthewalls.SeeFigure3.6.

Levelthefireplaceandshimasnecessary.

These surfaces must be even!

Drywall Non-combustiblefacing material

Figure 3.6 Drywall - Non-combustible Facing Material

14 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 15: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

1in. (25 mm) Overlap

Metal strips 2 in. (51 mm) under edge of Fireplace and Hearth Extension and extended 2 in. (51 mm) beyond both sides of fireplace opening.Nail or screw metal strips in place.

Pallet Mounting/Floor Brackets

Raised Platform

Floor

2 in.(51 mm)

1 in. (25 mm) min.overlap

2 in.(51 mm)

Top piece must overlapbottom piece

Figure 3.8 Protect the Front of an Elevated Platform

F. Protective Metal Hearth Strips

Figure 3.7 Position the Protective Metal Hearth Strips

• Locatethetwoprotectivemetalhearthstripsmeasuringapproximately26in.x4in.(660mmx102mm)includedwiththisfireplace.

• Slideeachmetalstrip2in.(51mm)underfrontedgeoffireplace.

• Overlapstripsinthemiddleoffireplaceopeningby1in. (25mm)minimum.

• Metal stripsmust extendbeyond the front and sidesof the fireplace opening by at least 2 in. (51mm),Figure3.7).

• Protectthefrontofaplatformelevatedabovethehearthextensionwithmetalstrips(notincludedwithfireplace)per Figure 3.8. See Section 6 for hearth extensioninstructions.

WARNING! Risk of Fire! Protective metal hearth strips MUST be installed on combustible surfaces. DO NOT cover metal strips with combustible materials. Sparksorembersmayigniteflooring.

WARNING! Risk of fire! High temperatures, sparks, embers or other burning material falling from the fireplacemayigniteflooringorconcealedcombustiblesurfaces.• ProtectivemetalhearthstripsMUSTbeinstalled.• Hearth extensionsMUSTbe installed exactly as

specified.

WARNING! Risk of Fire!Follow these instructions exactly.Facing materials must be installed properly to prevent fire.No materials may be substituted without authorization by Hearth & Home Technologies.

G. Facing Material

TOOLS NEEDED: Powered drill with #2 Phillips head bit;caulkinggun.Onlynon-combustiblematerials(suppliedwithfireplace)maybeusedtocoverthemetalfireplacefront.

NOTE: All boards are pre-drilled for your convenience. Boards MUST be attached in the following order: bottom, top, and then the two sides, red-painted side out. The top and bottom board should each have a hang tag attached. Leave them attached for referral for the finishingoperation.

• Attach the bottom board to the bottom of the outerfireplacecanwithenclosedscrews,ensuringtheboardiscentered.DO NOT remove hang tags.

• Centerandattachthetopboardtotheoutercanandframingmembers. DO NOT remove hang tags.

• Using the SuperCalstick, run a light bead (1/8 in.minimum)between themetalsurfaceof thefireplaceandthebuttedgesofthetopboard.SeeFigure3.9.

• Ensuringthetopofthesidepiecesandthetopboardalign,attachthesidepiecestotheoutercanandframingmembers.

NOTICE: 1/8 in. of the facing material may be visible afterfinishingmaterialsareapplied.This1/8 in.mustbe painted or the red will show.

Figure 3.9 Apply Non-combustible Materials

Side Board

Bottom Board

Side Board

Top Board

DO NOT remove hang

tags

Apply bead of Super Calstick to

edge here

15Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 16: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

H. Outside Air KitAnoutsideairkitmustbeusedforcombustion.Hearth&HomeTechnologiesrecommendsyouutilizetheshortestductruntooptimizetheperformanceoftheoutsideairkit.Theoutsideairinlethoodshouldbepositionedinamannerthatwillnotallowsnow,leaves,etc.toblocktheinlet.Insomeinstallationstheairductmayneedtoberunvertically.Insuchaninstallation,a3ft(914mm)heightdifferencemustbemaintainedfromthetopoftheupper-mostchimneysectiontotheoutsideairinlethood.

RefertoFigures3.10and3.11whenplacingtheoutsideairinlethood.

Theoutsideairkitisinstalledontherighthandsideofthefireplace.SeeFigure3.12forhandlelocation/operation.

• Cuta6in.(152mm)holeinoutsidewalltoaccommodateairpiping.

• Use6in.(152mm)metalflexorrigidpiping(notsupplied)todirectlyconnectoutsideairtofireplaceintake.Insulatethepipetopreventfrostcondensation.

• Usethesuppliedoutsideairinlethood.• Seal between thewall and the pipewith silicone to

preventmoisturepenetrationandairleaks.• Sealbetweentheoutsideairinlethoodandthehouse

withsiliconetopreventairinfiltration.

CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp.

CAUTION! Risk of Fire or Asphyxiation! DO NOT draw outsidecombustionairfromwall,floororceilingcavity,orenclosed spaces such as an attic or garage. • DO NOT place outside air inlet hood close to exhaust

vents or chimneys. Fumes or odor could be drawn into theroomthroughthefireplace.

• Locateoutsideairinlethoodtopreventblockagefromleaves, snow/ice, or other debris. Blockages could cause combustion air starvation.

16 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 17: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

3 ft. (91cm) min. from top of uppermost chimney section to outside air inlet.

Locate outside air inlet to prevent blockage from leaves, snow/ice, or other debris.

Attic insulation shield must be used to keep insulation away from chimney.

Ceiling firestop on floor of attic

Outlet blocked bysnow, leaves, etc.

NO

Garage orcombustible

liquids storage

NO

Attic spaceNO

Outlet placedhigher than 3 ft

below thetermination cap

NO

UL181 Listed Class 0 or Class 1 metal flex orrigid duct Figure 3.11 Outside Air Installation

Figure 3.10 Outside Air Inlet Locations

17Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 18: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

I. Auxiliary Convection Air SystemNote: Boththeoutsideairandauxiliaryairkitsareinstalledontherighthandsideofthefireplace.

Theauxiliaryconvectionairsystemallowstheoptionatthetimeofinstallationofthefireplace,toruna6inch(152mm)diameterducttotheoutsideofthehome,andbringoutsideairoverthefanswhereitisheatedandthendistributedintotheroom.Thisproducesapostivepres-sureinsidethehome.

Figure 3.13 Auxiliary Convection Air Duct

Alternatively,a6inch(152mm)ductcanberuntoan-otherlocationinthehomeandusedasacoldairreturnwithinthehomeanddistributedintotheroomwherethefireplaceislocated.SeeFigure3.13.

Ifnoductingisinstalled,thefanswillpullairfromtheroomandre-circulateheatedairbackintotheroom.

Figure 3.12 Outside Air

Termination Caps supplied with fireplace

UL 181 Listed Class 0 or Class 1 metal flex or rigid duct

Outside Air intake

Auxiliary Convection

Air

Open/Close Knob for

outside air

OUTSIDE AIR

OPENCLOSED

18 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 19: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

Auxiliary Convection Air LeverTheauxiliaryconvectionairleverislockedfromthefac-tory.Ifyouaregoingtousethisfunctionforairmove-mentyoumustremovethelock.

Afterremovingthefascia,removetheonescrewandplatetoallowthehandletobemovedinthefullmotionrighttoleft.SeeFigure3.14.

Discardtheplateandscrew.Replacefascia.

The auxiliary convection lever is located underneaththefrontlowerpanelasshowninFigure3.14.

Figure 3.14 Auxiliary Convection Air Lever

8-32 Screw

Convection Lock Bracket

19Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 20: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

DUCT RUN REQUIREMENTS

MAXIMUMDuctRun=40-ft.(12m)MINIMUMDuctRun=36in.(914mm)

DUCTING MATERIAL

6in.(152mm)B-VentOnlyDONOTductintoexistingfurnaceplenum

MINIMUM CLEARANCE TO COMBUSTIBLES

1in.(25mm)fromtheB-Vent1/2in.(13mm)fromtop&bottomofoutletbox0in.(0mm)fromthesidesofoutletbox12in.(305mm)fromwallregistertoceilingRefertoFigure3.15.

CAUTION! ALLwiringshouldbedonebyaqualifiedelec-trician and shall be in compliance with local codes and with the National Electric Code NFPA/NEC No. 70-current. CSC22.1 Canadian Electric Code.

Possible Air Duct Runs / Locations

Figure 3.15 Minimum Clearances to Combustibles

Ceiling RegisterWall Register

Floor Register

Two Duct Kits

Ceiling Register

12 in. (305mm) minimum clearance from register to ceiling

J. Heat Zone Kit (Optional)TheHeat-Zoneaccessorykitconveyswarmairfromthefireplacethroughairduct(s)toremotelocationsinthesameroomorotherroomsofthebuilding.Youmayinstall1or2Heat-Zonekitsonthefireplace.InstallationofthiskitMUSTbeperformedbyaqualifiedservicetechnician.Ifanypartsaremissingordamaged,contactyourlocaldealerbeforestartinginstallation.DONOTinstalladam-agedkit.

Thiskitistestedandsafewheninstalledinaccordancewiththisinstallationmanual.Itisyourresponsibilitytoreadallinstructionsbeforestartinginstallationandtofol-lowtheseinstructionscarefullyduringinstallations.

TheHeat-Zone®Woodkitiscarefullyengineeredandmustbeinstalledonlyasspecified.Ifyoumodifyitoranyofitscomponentsyouwillvoidthewarrantyandyoumaypossiblycauseafirehazard.Installationmustbedoneaccordingtoapplicablelocal,state,provincialand/ornationalcodes.

Planthelocationofthefireplaceandwarmairductrun(s).

20 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 21: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

Installation• Removetheknockoutorcoverplatefromthetopofthe

fireplaceanddiscardit.SeeFigure3.16.• Cuta3in.(76mm)holeintheinsulationboardasper

thedimensionsshowninFigure3.16.

Adapter

Mounting Plate

Starter Pipe

Knockout

Cut a 3 in. (76 mm)

hole in insulation board

3-13/16 in. (97 mm)

3-1/8 in. (79 mm)

CL

Run Length Cut Pipe20 - 40 ft (6-12 m) 2 in. (51 mm)*

*A minimum of 2 in. (51 mm) pipe must be used to cover the raw insulation to prevent it from blowing out through the return air grille.

10 - 20 ft (3 - 6 m) 8 in. (203 mm) 3 - 10 ft (1 - 3 m) No cut needed**

**Use full 16 in. (406 mm) as supplied

• DeterminethenecessarylengthofstarterpipefromtheTable3.1andcutasrequired.

Figure 3.16

• Slide the starter pipe into the fireplace,matching theholesintheplatetotheholesinthefireplace.

• Placetheadapteronthemountingplateliningupholes.Usingfoursheetmetalscrewsincludedinthekit,securethe adapter andmounting plate into fireplace.Aftersecuringtothefireplace,tapedowntheadapteredgestothetopofthefireplacewithaluminumtapetopreventleakage.

• Determine the location for the air register and fanhousingassembly.Cuta7-5/8in.x13-5/8in.(143mmx346mm)holebetweenframingmembers(wallstudsorfloor joists).Thebracketscanberotated180°andmountedtothebacksideofthe2x4ifnecessary.SeeFigure3.18.

NOTICE: The fan and electrical connections must be accessible for servicing per local code requirements.

NOTICE: If the fan housing is installed in a 2 x 4 wall, the front of the housing will protrude approximately 1/4 in.(6mm)fromthefinishedwall.

• Attachenough6 in. (152mm)B-Ventas required foryourinstallationtothefanhousing.A maximum of (4) 90° elbows is recommended. Securely twistlocktheB-Venttotheadapter. AlsoscrewtheB-Venttotheoutletboxonthefan

housing.SeeFigure3.19.Supportductatintervalsofnogreaterthan4ft(1m)asrequiredbylocalcode.

Figure 3.17

WARNING! Risk of Fire! Comply with all minimum clearancesspecified.• A minimum 1 in. (13 mm) air clearance must be

maintained at the back and 1 in. (25mm) to the sides ofthefireplaceassembly.

NOTE: It is important the pipe length be adhered to or it will affect the performance of your fireplace.

• Onthemountingplate,handbendthetabsdownward.Slidethetabsovertheoutsideofthestarterpipe.Securewith four sheetmetal screws included in fastenerspackage.Figure3.17.

Table 3.1

21Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 22: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

Securely Twist Lock B-Vent to Adapter

Secure B-Vent to Fan Housing with sheet metal screws

Return Air GrilleInstall with Louvers pointed down

Bracket

Can rotate 180o

2 x 4 Wall

Fan Housing

1/2 in. (13mm)clearance tocombustiblesmust bemaintained.

2 x 4 wall

Sheet Rock

Leave 1/4" (6mm) clearance from all 4 outer edges

Seal grille using gasketing supplied with the kit

• Installthevariablespeedwallrheostat(withsettingon“OFF”)inaconvenientlocation.ThisswitchwillcontroltheHeat-Zonefanoperation.

• Remove the junctionbox.Wire110VACserviceTOthewall rheostatandFROM thewall rheostat to thefanjunctionbox.Usewirenutstosecurethe110VACservicewirestothehot(black)andneutral(white)fanwiresandscrewthe110VACgroundwiretothejunctionbox.SeeFigure3.21.

• Securethereturnairgrilletothefanhousingmakingsure it is flush.Thegrillemust be installedwith thelouverspointingdown.

NOTICE: DO NOT USE ADJUSTABLE REGISTERS.

Junction Box Removed

Wire Clamp

Wire Nuts

Junction Box

Bla

ck

White

NOTICE: Secure the duct so that clearance to the fire-place outer wrap is maintained. Tape all seams with alumi-numtape1-1/4in.(32mm)minimumwidthorasspecifiedby local codes.)• Sealallthewayaroundtheinsideofthereturnairgrilleto

preventhotairbeingdrawnbackintotheventingsystemusinggasketingsuppliedwiththekit.Leave1/4in.(6mm)clearancefromallfourouteredges.Trimexcessgasketing.SeeFigure3.20.

Figure 3.18

Figure 3.19

Figure 3.20

Figure 3.21

22 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 23: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

14-2 w/ground

Standard wall mount with Junction Box

14-3 w/ground

WIRE NUT

WHITE

GREEN

BLACK

BLAC

K

RED

WHITEMatch colors to wire harness (red to red, white to white, etc) and secure with a wire nut

Incoming Power(110V)

Power to the FireplaceSnap Disc bypass switch

Figure 4.1 Fan Wiring Diagram

NOTICE: The manual override switch, rheostat speed control and cover plate are supplied. You will need to supply: 14-3 wire with ground; 14-2 wire with ground; standard wall mount junction box; wire nuts.

• Remove junctionboxcoverplateon thebottomrightsideofthefireplace.

• Threadthe14-3withgroundwirethroughtheopeningwiththestrainreliefonthecoverplate.

• Matchcolorstowireharness,(redtored,whitetowhite,etc.)andsecurewithwirenuts.

WARNING! Risk of Fire! DO NOT applycombustiblefin-ishingmaterialsoveranypartofthefrontofthisfireplace.• Themetal fireplace facemay only be coveredwith

noncombustible materials such as ceramic tile, brick, or stone.

• Donotcoverorblockanycoolingairslots.

NOTICE: Wiring for fans must be done before framed enclosure is completed. If using a Heat Zone kit, it also must be installed before enclosure is complete.

4 Electrical Wiring

23Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 24: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

6 ft (1.8 m) max.unsupportedrun

20 ft (6.10 m) max.pipe between anoffset & return

Ceiling firestop

35 ft (10.7 m)max. straightunsupported

chimney height

14.5 ft (4.42 m) min. height/single offset-return20 ft. (6.10 m) min. height/double offset-return

50 ft (15.24 m) max. height

6 ft (1.83 m) max.unsupported chimneyabove roof

45 3/4 in.(1162 mm)to top of standoffs

Attic Insulation Shield

Chimney Air Kit required with SL

chimney

Figure 5.1 Chimney Requirements

NOTICE: A maximum of two pairs of offsets and returns may be used.

Minimum overall straight height 13 ft 3.96 mMinimum height with single offset/return

14.5 ft 4.42 m

Double offset/return minimum height 20 ft 6.1 mMaximum height 50 ft 15.24 mMaximum chimney length between an offset and return

20 ft 6.1 m

Maximum distance between chimney stabilizers

35 ft 10.67 m

Maximum unsupported chimney length between the offset and return

6 ft 1.83 m

Maximum unsupported chimney heightabovethefireplace

35 ft 10.67 m

Maximum unsupported chimney above roof

6 ft 1.83 m

WARNING! Risk of Fire! You must maintain 2 in. (51 mm) air space clearance to insulation and other combustible materials around the chimney system. Failure to do so maycauseoverheatingandfire.

NOTICE: You must provide support for the pipe during construction and check to be sure inadvertent loading has notdislodgedthechimneysectionfromthefireplaceoratany chimney joint.

A. Chimney RequirementsVerticaldistancesaremeasuredfromthebaseofthefireplaceasshowninFigure5.1.

5 Chimney and Termination Requirements

Table 5.2 Chimney Component DimensionsTable 5.1 Chimney Requirements

HEIGHT OF CHIMNEY COMPONENTS in. mm

Chimney Stabilizer

SL3 4-3/4 121

Offsets/Returns

SL315 13-3/8 340

SL330 15-1/2 394

Chimney Sections*

SL306 4-3/4 121

SL312 10-3/4 273

SL318 16-3/4 425

SL324 22-3/4 578

SL336 34-3/4 883

SL348 46-3/4 1187

* Dimensions reflect effective height.

24 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 25: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

Table 5.3 Offset Dimensions

B. Offsets/Returns• Useanoffset/returntobypassoverheadobstructions.• Anoffsetandreturncanbeusedasasingleentityorseparatedbychimneysection(s).

WARNING! Risk of Fire! DO NOT use offset/returns greater than 30°. Chimney draft will be restricted and could cause overheatingandfire.Secureoffsetswithscrews(nottoexceed1/2”/13mminlength)Securereturnswithstrapping.Straight chimney sections may be secured with screws. Keep chimney sections from separating or twisting.

• Measuretheshiftneededtoavoidtheoverheadobstruction.RefertodimensionAinFigure5.2.• FindtheappropriateAdimensionlistedinTable5.3.TheBdimensioncoincidingwiththeAdimensionmeasurementin

Table5.3representstherequiredverticalclearanceneededtocompletetheoffset/return.• Readacrossthecharttofindthenumberofchimneysections/modelnumbersneededbetweentheoffsetandreturn.

A

B

1-1/4 in. (32 mm)OVERLAP

Figure 5.2 Chimney Offset/Return

Example: Your“A”dimensionfromFigure5.2is14-1/2in.(368mm).UsingTable5.3thedimensionclosestto,butnotlessthan14-1/2in.(368mm)is14-1/2in.(368mm)us-inga30°offset/return.

Youdeterminefromthetablethatyouneed34-1/8in.(867mm)(Dimension“B”)betweentheoffsetandreturn.

ThechimneycomponentthatbestfitsyourapplicationisoneSL324.

15-degree 30-degree

SL306 SL312 SL318 SL324 SL336 SL348A B A B

in. mm in. mm in. mm in. mm15/8 41 133/8 340 35/8 92 151/2 394 - - - - - -

27/8 73 173/4 451 51/2 140 185/8 473 1 - - - - -

41/8 102 223/8 568 71/4 184 213/4 552 2 - - - - -

41/2 114 235/8 600 81/2 216 233/4 603 - 1 - - - -

53/4 146 281/4 718 101/4 260 27 686 1 1 - - - -

6 152 293/8 746 111/2 292 29 737 - - 1 - - -

71/4 184 34 864 131/4 337 321/8 816 - 2 - - - -

73/4 197 361/8 918 141/2 368 341/8 867 - - - 1 - -

83/4 222 393/4 1010 161/4 413 373/8 949 1 - - 1 - -

103/8 264 455/8 1159 191/4 489 421/2 1080 - - 2 - - -

105/8 270 463/4 1187 201/2 521 445/8 1133 - - - - 1 -

117/8 302 513/8 1305 221/4 565 473/4 1213 1 - - - 1 -

131/2 243 571/4 1454 251/4 641 527/8 1343 - - - 2 - -

133/4 349 583/8 1483 261/2 673 55 1397 - - - - - 1

15 381 63 1600 281/4 718 581/8 1476 1 - - - - 1

161/2 419 683/4 1746 311/4 794 631/4 1607 - 1 - - - 1

18 457 745/8 1895 341/4 870 681/2 1740 - - 1 - - 1

195/8 498 803/8 2042 371/4 946 733/4 1873 - - - 1 - 1

205/8 524 841/8 2137 391/8 994 767/8 1953 1 - - 1 - 1

223/4 578 917/8 2334 431/4 1099 841/8 2137 - - - - 1 1

24 610 961/2 2451 451/8 1146 871/4 2216 1 - - - 1 1

257/8 657 1031/2 2629 491/4 1251 941/2 2400 - - - - - 2

Properassemblyofair-cooledchimneypartsresultinanoverlapatchimneyjointsof1-1/4in.(32mm).Effectivelengthisbuiltintothischart.

25Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 26: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

Slanted Roofs

Flat Roofs

Chimney mustextend 3 ft (.9 m)above the roof

Chimney must extend 2 ft (.6 m)above any portion of the roof oradjacent structures within 10 ft (3 m) of the chimney

Chimney mustextend 3 ft (.9 m)above the roof

Chimney must extend 2 ft (.6 m)above any portion of the roof oradjacent structures within10 ft (3 m) of the chimney

Multiple Chimney Locations

A B6 in. (minimum) up to 20 in.

152 mm/508 mm18 in. minimum

457 mm20 in. and over 0 in. minimum

Gas, Wood or Fuel OilTermination Cap

WoodMinimum

(Seeillustration

above)

B

GasTermination

Cap **

A *

Per

pend

icul

ar W

all

* If using decorative cap cover(s), this distance may need to be increased. Refer to the installation instructions supplied with the decorative cap cover.

** In a staggered installation with both gas and wood terminations, the wood termination cap must be higher than the gas termination cap.

Figure 5.3 Multiple Chimney Locations

C. Termination Requirements• Installacapapprovedandlistedforthisfireplacesystem.• Locatecapwhereitwillnotbecomepluggedbysnoworothermaterials.• Locatecapawayfromtreesorotherstructures.• Thebottomoftheterminationcapmustbeatleast3ft(.91m)abovetheroofANDatleast2ft(.61m)aboveanyportion

ofroofwithin10ft(3.05m)asshowninFigure5.3.• ThedistancerequiredbetweencapsisshowninFigure5.3.

26 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 27: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

6 Chimney Installation

Termination Cap

Additionalsupport fortall chimneys

Storm Collar

Maintain minimumclearances to combustibles asspecified

Chimney must extendbeyond combustibleroof structure

Maintain minimumheight of chimneyabove roof

Install roof flashingaccording to minimumrequirements

Offsets/returnsmay not exceed30° from vertical Support straps for offsets/

returns must be securedto adequate framing

Ceiling firestopsare required wherechimney passes through ceiling orfloor

Attic Shield isrequired where chimneypasses through attic

Figure 6.1 Typical Chimney System - Guidelines for Chimney System Installation

NOTICE: Chimney performance may vary.

• Trees,buildings,rooflinesandwindconditionsaffectperformance.• Chimneyheightmayneedadjustmentifsmokingoroverdraftoccurs.

A. Typical Chimney System

27Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 28: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

Attach Flue First

CAK4A

Secure with Screws Provided

Push TogetherSecure to Top

C. Install Chimney Air kit (CAK4A)

NOTICE: Chimney Air Kit, Part CAK4A is required when using the SL-300 Pipe Series. Detailed instructions are supplied with the kit. If using the Dura-Plus System (must be 8 in./203 mm in diameter), the starter ring that came withthefireplacemustberemovedandreplacedwiththeDura-Plus Base Plate. The CAK4A is not required with a Dura-Plus System.

• Installthechimneypipefirst.• Handbend the tabs inpositionbeforeplacingon the

fireplace.• Placetheboxontopofthefireplacearoundthechimney

pipe,pushbothpiecestogetherandsecurewithscrewsprovided.

• Usethepre-punchedholesinthetabsasguidesanddrillholesthroughthefireplacetop.

• SecuretheCAK4Ainplace.SeeFigure6.3.• Sealaroundthekitattheflueandatthetopofthecan

withcaulk.SeeFigure6.3.

Figure 6.3 Installing the CAK4A

NOTICE: Chimney sections cannot be disassembled once locked together. Plan ahead!

• Lockchimneysectionsand/oroffsets/returnstogetherbypushingdownwarduntilthetopsectionmeetsthestopbeadonthelowersection.

• Pullonthetopsectiontomakesureitisfullyengagedandwillnotseparate.

• Youmayuse#6or#8sheetmetalscrewsnolongerthan1/2in.(13mm)tofastenchimneysectionstogether.DoNOTpenetrateinnerflue.

WARNING! Risk of Fire! You MUST use screws (pro-vided) to fasten offset/returns to chimney sections to keep the chimney parts from twisting. Failure to do so couldcausefire.

• Fasten offset/returns to chimney sections. Insert thescrews(provided)throughthepredrilledholes.DoNOTpenetrateinnerflue.

• Secure chimney returnswithhanger strapsprovided;fastentostudsorjoists.

• Verticalstraightrunsofchimneymustbesupportedevery35ft(10.7m).

B. Assemble Chimney Sections Useonlythosecomponentsdescribedinthismanual.

Substituteordamagedchimneycomponentscouldimpairsafeoperationandcauseoverheatingandfire.

Attacheitherastraightchimneysectionoranoffsettothetopofthefireplace(dependingonyourinstallationrequirement).Chimneysectionsarelockedtogetherbypushingdownwarduntilthetopsectionmeetsthestopbeadonthelowersection.

Theinnerflueisplacedtotheinsideofthefluesectionbelowit.Theoutercasingisplacedoutsidetheoutercas-ingofthechimneysectionbelowit.SeeFigure6.2.

WARNING! Risk of Fire! DO NOT install substitute or damaged chimney components.

Figure 6.2 Assembling Chimney Sections

28 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 29: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

NOTES: • TheCAK4Aterminationcapmustbeaminimumof4ft

(1219mm)abovethegroundandkeptfreeofdebris.• If theCAK4A is installed inachase, theCAK4Aside

terminationcapmustbeat least3ft(914mm)belowthechimneytop.

• Sealaroundthecapandflexwithcaulktostopairfromgettingintothechase(seeFigures6.4).

Wire Ties

Seal

Seal

4" Duct - Use UL181 Class 0 or Class 1 ducting.

Figure 6.4 Installing Flex Pipe

WARNING! Risk of Fire!• Theflexpipemustneverbecompressedordeformed!• Restrictingtheairflowinsidetheflexpipemayincrease

fluepipetemperaturescausingachasefire.

29Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 30: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

D. Secure Offset/Return

E. Install Ceiling Firestops CAUTION! Risk of Fire! Ceilingfirestopsmustbeused

wheneverthechimneypenetratesaceiling/floor.• Chaseconstructionrequiresceilingfirestopsateach

floororevery10ft.(3.05m)ofclearspace.• Theceilingfirestopslowsspreadoffireandreduces

coldairinfiltration.

• Installaceilingfirestopwheneverchimneypenetratesceiling/floor.

• MarkandcutanopeninginceilingasshowninFigure6.6.• Frametheopeningwiththesamesizelumberusedin

theceilingjoists.• Nailtheceilingfirestoptothebottomoftheceilingjoists

whenthereisaroomabove.• Useanatticinsulationshieldiftheceilingisinsulated.

Theceilingfirestopmaythenbeattachedaboveorbelowthejoists.

ROOM ABOVE (non-insulated ceiling)

ATTIC ABOVE (insulated ceiling)

B A

Ceilng firestop attached to bottom

of framing

Ceiling firestop attached to top of

framing

Note: Use same dimensional lumber for framing ceiling firestop and joists.

2 in. (51mm) clearance

2 in. (51mm) clearance

WARNING! Risk of Fire! DO NOT seal area between firestopopeningandchimneypipeexceptwheretheyen-ter the attic or leave the warm air envelope of the home (use 600° F sealant).

Figure 6.6 Installing the Ceiling Firestop

Whenoffsetsandreturnsarejoinedtostraightpipesec-tions,theymustbelockedintopositionwiththescrewsprovided*(outeronly),usingthepredrilledholes.Topre-ventgravityfrompullingthechimneysectionsapart,thereturnsandthechimneystabilizershavehangerstrapsforsecuringthesepartstojoistsorrafters.SeeFigure6.5.

* Use#6or#8sheetmetalscrew,orlarger,nolongerthan1/2in.(13mm).

WARNING! Risk of Fire!• Secureoffsetswithscrews(nottoexceed1/2in./13mm

In length).• Securereturnswithstrapping.• Straightchimneysectionsmaybesecuredwithscrew

(not to exceed 1/2 in./13 mm In length) at the joints.• Keepchimneysectionsfromseparatingortwisting.

CeilingFirestop

Straps

OptionalAdditionalSupport

JointBand

(Optional)

Figure 6.5 Secure the Chimney

Catalog #A B

in. mm in. mm

FS338 14-1/2 368 14-1/2 368

FS339 14-1/2 368 18-3/8 467

FS340 14-1/2 368 23 584

30 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 31: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

Installationofaceilingfirestopisrequired:

• RefertoFigures6.7,6.8,6.9.• Rolltheshield(aroundthechimneyifalreadyinstalled).

Thethreeholesoneachsidewillmatchup(largeholesontop).

• Insert threescrews into thematchingholes to formatube.

• Bendthetabsonthebottomofthetubeinwardto90°tomaintainchimneyairspace(refertoFigure6.8).

• Resttheinsulationshieldontheceilingfirestopbelow.• Bendthetabsatthetopoftheshieldinwardto90°to

maintainthe2in.(51mm)airspacefromthechimney.

Ifyouwishtomakeacustomshieldorbarrier,followtheseguidelines:

• Metalispreferred,althoughanymaterialstiffenoughtoholdbacktheinsulationcanbeused.

WARNING! Risk of Fire! Use of cardboard or other materialsthatcandeflectunderhumidityorotherenvi-ronmental conditions is not recommended.

• The shield or barriermust be tall enough to extendabovetheinsulationandpreventblown-ininsulationfromspillingintothecavity.

• Maintainspecifiedairspacesaroundchimney.• Checkinstructionsandlocalcodesforfurtherdetails.

Insert three screws

Tabs bent 90°

Figure 6.7 Prepare Attic Insulation Shield

Tabs bent in 90°and taped

Tabs bent 90° to rest against pipe

Attic Insulation Shield

Ceiling Firestop

10-1/2 in.(267 mm)

14-1/2 in. (368 mm)diameter

InsulationInsulation

Pipe

Pipe

2 in. (51 mm)air space

Tabsbent in 90°and taped

Tabs bent 90° to rest against pipe

Attic Insulation Shield

Ceiling Firestop10-1/2 in.(267 mm)

14-1/2 in. (368 mm)diameter

InsulationInsulation

Pipe

Pipe

2 in. (51 mm)air space

Figure 6.8 Install Attic Insulation Shield (firestop above ceiling)

Figure 6.9 Install Attic Insulation Shield (firestop below ceiling)

F. Install Attic Insulation ShieldWARNING! Risk of Fire! You MUST install an attic insu-lation shield when there is any possibility of insulation or other combustible material coming into contact with the chimney. • DO NOT pack insulation between the chimney and the

attic insulation shield. • Failuretokeepinsulationandothermaterialsawayfrom

chimneypipecouldcausefire.• DO NOT offset chimney inside insulation shield.

Double-check the Chimney AssemblyContinueassemblingthechimneysectionsupthroughthe ceiling firestops as needed. While doing so, beawareof theheight andunsupported chimney lengthlimitationsgivenunderSection5.

Checkeachsectionbypullingupslightlyfromthetoptoensureproperengagementbeforeinstallingthesuc-ceedingsections.Iftheyhavebeenconnectedcorrect-ly,theywillnotdisengagewhentested.

31Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 32: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

G. Roof Penetration• RefertoFigure6.10.• Plumbfromrooftocenterofchimney.• Driveanailupthroughrooftomarkcenterofpipe.• Measuretoeithersideofnailandmarkthe14-1/2in.x

14-1/2in.(368mmx368mm)openingrequired.• Measureopeningonthehorizontal;actuallengthmay

belargerdependingonroofpitch.• Cutoutandframeopening.• RefertoChapter 25 of the Uniform Building Code for

roofframingdetails.

Figure 6.10 Ceiling/Attic Construction

Install Flashing• Assemblechimneysoitpassesthroughtheframed

opening.• Sliptheflashingoverthechimney.

NOTICE: Roofingshinglesmustbebelowtheflashingplate on the lower side of a sloped roof and over the flashingplateonthesidesandtop.

• Nailtheflashingtotheroof.Keepgapsbetweentheflashingplateandtherooftoaminimum.

• Caulktheflashingplateandroofjunctionaswellastheverticalseamontheflashing.Allnailheadsmustbecaulkedwitharoofingsealant.

• Caulktheoverlapseamofanyexposedpipesectionsthatarelocatedabovetherooflinetopreventleaks.

CHIMNEY

FLASHING PLATE

JOISTS

NAIL

THIMBLE

FLASHING

Figure 6.11 Installing Part: 12966A, Configuration 1

NOTICE: REQUIRED for manufactured homes.

• Locatethepointwherethechimneywillexittheroofbyplumbingdowntothecenterofthechimney.Layout,cutand framea14-1/2 in. (368mm)squareopening(measuredonthehorizontal)throughtheceilingandroofstructure.Consult local codes for framing details.

• The thimblemustextendcompletely through theroofstructureshieldingcombustiblematerials.Fivelocationholeshavebeenprovidedtoallowforavarietyofceiling/roofthicknesses.Athimbleextensionisrequiredwhentheceiling/roofthicknessexceeds12-1/2in.(318mm).Theextensionshouldoverlapthethimbleoneinch.

• Toattachtheextensiontothethimble,drill1/8in.(3mm)holesthroughtheoutershieldofthethimbleusingthepredrilledholesintheextensionasguides.Attachtheextensiontothethimbleusingthescrewsprovidedwiththeextension.

• Installthethimbleassemblyandnailitsecurelytotheframingmembers.

H. Manufactured Home Installation SL-300 Series Ceiling/Roof Thimble

• Centertheflashingoverthechimneyandnailittotheroof.Keepgapsbetweentheflashingplateandtherooftoaminimum.Caulktheflashingplateandroofjunctionaswellastheverticalseamontheflashing.Allnailheadsmustbecaulkedwitharoofingsealant.

• Finish assembling the chimney storm collar andtermination cap following the installation instructionsprovidedwiththem.

32 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 33: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

NAIL

FLASHING PLATE

CHIMNEY

THIMBLE EXTENSION

SCREW

FLASHING

THIMBLE ADJUSTABLE EXTENSION HOLES

Figure 6.13 Installing Part 12966A Configuration 3

I. Install Chase/Chase Top• YouMUSTuseachasetopinachaseinstallation.

Chase tops are available from yourQuadra-Firedealerormaybefieldconstructed.

• Includeaturndownanddripedgetopreventwaterfromseepingintothechase.

• Includea2 in. (51mm)soldered,weldedorspuncollararoundpipeopeningtokeepwaterout.

• Providea1/8in.(3mm)gaparoundthefluepipe.• Slope the chase top downward away from the

opening.

WARNING! Risk of Fire! DO NOT caulk the pipe to the chase top collar. • Caulkallseamstopreventleaks.

Slope Downward(1/4 in. per footminimum)

Turn-down Drip Edge

Chase

2 in. (51 mm) Collar on Chase Top

.018 (26 ga) min. Galvanized Chase Top

Figure 6.14 Chase Top Construction

FLASHING

CHIMNEY

FLASHING PLATE

NAIL THIMBLE

SCREW

THIMBLE EXTENSION

Figure 6.12 Installing Part 12966A, Configuration 2

33Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 34: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

J. Termination Cap Requirements• Installacapapprovedandlistedforthisfireplacesystem.• Locatecapwhereitwillnotbecomepluggedbysnow

orothermaterials.• Locatecapawayfromtreesorotherstructures.• Thebottomoftheterminationcapmustbeatleast3ft

(.91m)abovetheroofANDatleast2ft(.61m)aboveanyportionofroofwithin10ft(3.05m).

StormCollar

ChimneyPipe

Chase Top

TerminationCap

Chase

6 in. (153 mm)Minimum top ofchase to top ofchimney pipe

Collar2 in. (51 mm)

Minimum Height

Do NOTblock air holes

Caulk gaps between storm collar & pipe,

and storm collar& chase top.

Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm).

Slipstorm collar

around chimney pipebefore termination

cap pipe is snapped into the chimney

pipe.

Figure 6.15 Installing a TR344 Round Termination Cap

StormCollar

ChimneyPipe

Chase Top

TerminationCap

Chase

14 1/2 in. (368 mm)Maximum

Collar2 in. (51 mm)

Minimum Height

Caulk gaps between storm collar & pipe,

and storm collar& chase top.

Do NOT block air

holes

3 clip brackets.Slip over chase collar

and attach with screwsprovided.

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Assemblestorm collar

around extended termination cap

pipeonce cap is

installed.

Figure 6.16 Installing a TR342 Round Telescoping Termination Cap

K. Install Termination CapInstallthechimneysectionsupthroughthechaseenclo-sure.

• Caulktheoverlapseamofanyexposedpipesectionsthatarelocatedabovetherooflinetopreventleaks.

• Refertoterminationcapinstructions.

WARNING! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from cap. Separation allows sparks, heat and embers to escape.

NOTICE: Paint the termination cap with a rust-resistant paint to protect against the effects of corrosion on those parts exposed to the weather.

34 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 35: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

ChimneyPipe

Chase Top

Termination Cap

Chase

Collar2 in. (51 mm)

Minimum Height

Place waterproof caulk or sealer under each flange of the termination cap and on top of each screw to help prevent leaks.

Flange

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

2 in. (51 mm)maximum

4 3/4 in. (121 mm)maximum

The last section of pipe must stop between 2 in. (51 mm) above the top of the chase and 4 3/4 in. (121 mm) below the top of the chase.

Figure 6.17 Installing an ST375 Square Termination Cap

ChimneyPipe

Chase Top

Termination Cap

Chase

Collar2 in. (51 mm)

Minimum Height

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm).

Place waterproof sealer under each flange of the termination cap and on top of each screw to help prevent leaks.

2 in. (51 mm)maximum

4 3/4 in. (121 mm)maximum

The last section of pipe must stop between 2 in. (51 mm) above the top of the chase and 4 3/4 in. (121 mm) below the top of the chase.

Figure 6.18 Installing a TS345/TS345P Square Termination Cap

ChimneyPipe

Chase Top

Termination Cap

Chase

Collar2 in. (51 mm)

Minimum Height

Remove 2 screws from front & back to lift the top off

Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm)

Place waterproof sealer under each flange of the termination cap and on top of each screw to help prevent leaks.

The last section of pipe must stop between 2 in. (51 mm) above top of chase and 7 in. (178 mm) below top of chase

2 in. (51 mm)

7 in. (178 mm)

Figure 6.19 Installing a TCT375 Terra Cotta Cap

35Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 36: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

7 Finishing

A. TemplateAcardboardtemplateofthefrontisprintedontheoutsideoftheshippingbox.Cutoutthetemplatealongtheout-sideofthelineforuseinyourinstallation.Ametaltem-plate(seecatalog)isavailableformoredurablecontin-ueduse,remainingaccurateovertime.Bothmeasure1/8in.(3mm)largerallthewayaroundthantheactualfront.

Note:This1/8in.ofthenon-combustiblematerialmustbepaintedortheredwillbevisible.

Tools Required: 1/8in.Allenwrench.• Removethedoorsonthefireplace(ifinstalled).• Removethescrewsfromthefasciaandremovefascia

fromthefireplace(ifinstalled).Savethescrews.Storethefasciainasafe,protectedareatopreventscratchingorotherdamage.

• Installthetemplateonthefrontofthefireplace(Figure7.1)usingthescrewssavedinthepreviousstep.

Youarenowreadytocontinueyourinstallationwiththedesireddecorativematerial.Thetemplatealsoservesasaprotectivecoveringandpreventsdamagetothefrontofthefireplace.

NOTE: The decorative fascia must be removable for future serviceability of the automatic combustion control.

Figure 7.1 Install the Finishing Template

Note: DO NOT remove hang tags until installing finishmaterials.

B Finish the WallUseawetordrytowelorasoftbrushtoremoveanydustordirtfromthenon-combustiblefacingmaterial.

Applyanon-combustibleadhesivetoattachtile,stoneorothernon-combustiblefinishingmaterialspermanufac-turer’sinstructions.

1. Stone, Brick FinishWARNING! Risk of Fire! DO NOT apply tar paper or water resistive barrier over non-combustible board.

• Applymetallathtothe1/2in.thicknon-combustibleboardwith corrosion resistant self-tapping screwscapableofpenetratingthemetalsurfacebehindthenon-combustibleboard.

• HHT recommendsusing typeNor typeSmortar.Duetohightemperatures,reviewpolymermodifiersspecificationsheetbeforeusing.

2. Tile, Granite, Marble Finish• Duetohightemperatures,HHTrecommendsusing

unmodifiedthinsetwhenapplyingtile.• Whenapplyinggraniteormarble,HHTrecommends

usingthinsettoadhere.Ifusingadifferentadhesive,review specification sheet for application in hightemperatureareas.

36 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 37: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

C. Mantel and Wall ProjectionsAcombustiblemantelmaybepositionednolowerthan60in.(1524mm)fromthebaseofthefireplace.

RefertoSection3forreducedmantelheightallowances.

Thecombustiblemantelmayhaveamaximumdepthof12in.(305mm).Combustibletrimpiecesthatprojectnomorethan3/4in.(19mm)fromthefaceofthefireplacecanbeplacednocloserthan6in.(152mm)fromthetoporsideofthedecorativefront.Combustibletrimmustnotcover:

• themetalsurfacesofthefireplace• where the non-combustible board is placedover the

metalsurfaces• thespacebetweenthemetalfaceofthefireplaceand

framingmembers

60 in.(1524 mm)

Mantel

Clearances are from bottom of appliance to lower edge of mantel or trim

Trim

48 in.(1219 mm)

36 in. (914 mm)

Ceiling/enclosure

Figure 7.2 Mantel Specifications - Combustible Mantel

D. Finishing the Hearth Extension

Table 7.1

R = 1/k x inches of thickness

Table 7.2

WARNING! Risk of Fire! High temperatures, sparks, em-bers or other burning material falling from the fireplacemayigniteflooringorconcealedcombustiblesurfaces.• ProtectivemetalhearthstripsMUSTbeinstalled.• Hearth extensions MUST be installed exactly as

specified.

Ahearthextensionmustbeinstalledwithallfireplacestoprotectthecombustiblefloorinfrontofthefireplacefrombothradiantheatandsparks.

• YouMUSTuseahearthextensionwiththisfireplace.

• RefertoFigure7.4forminimumdimensions.• Thisfireplacehasbeentestedandapprovedforusewith

ahearthextensioninsulatedtoaminimumRvalueof2.06.

• ThehearthextensionmaterialMUSTbecoveredwithtile,stoneorothernon-combustiblematerial.

• Manufactured hearthmaterials will usually have apublishedR value (resistance to heat) or k value (conductivityofheat).RefertotheformulainTable7.1toconvertakvaluetoanRvalue,

• Refer to Table 7.2 for hearth extension insulationalternatives.

Hearth Extension Insulation Alternatives, R Value = 2.06

Materialk per inch

thickr per inch

thick

Minimum thickness required

Hearth&HomeHX3,HX4 0.49 2.06 1in.

USGMicore300™ 0.49 2.06 1in.

USGDurock™CementBoard 1.92 0.52 4in.

CementMortar 5.0 0.20 101/2in.

CommonBrick 5.0 0.20 101/2in.

CeramicTile 12.50 0.08 253/4in.

Armstrong™PrivacyGuardPlus 0.46 2.18 1in.

Marble 14.3-20.0 0.07-0.05 29 1/2 - 41 1/4 in.

Anoncombustiblemantelmaybepositionednolowerthan46in.(1168mm)fromthebaseofthefireplace.

Noncombustibleframingmaterialsmustbeusedabovethefireplacetoaheightof84in.(2134mm)ortotheceilingfromthebaseofthefireplaceforallconstruc-tionmaterials,framingmembers,sheeting,andallfinishmaterials.

Figure 7.2 Mantel Specifications - Non-Combustible Mantel

46 in.(1168 mm)

Noncombustible Mantel

Clearances are from bottom of appliance to lower edge of mantel or trimAll construction materials, framing members, sheeting and finish materials MUST be noncombustible.

37Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 38: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

8 in. (203mm) minimum from each side offuel loading door

AB

Figure 7.3 Minimum Hearth Extension Dimensions

Model # 7100FP A Bin. 41 20mm 1041 508

• FireplaceandHearthExtensionflushonthefloor Non-combustibleflooringaminimumof20in.(508mm)

infrontofand8in.(203mm)toeithersideofthefuelopeningisrequiredasshowninFigure7.3.

The construction of, andmaterials used for a hearthextensionareshowninFigure7.4.Ahearthextensionof this constructionmay be coveredwith any non-combustible decorativematerial andmay have aminimumthicknessasperFigure7.4.Sealgapsbetweenthehearthextensionandthefrontofthefireplacewithabeadofnon-combustiblesealantorgrout.

FasciaOuter Can Flange

Protective metalhearth strip

Tile,marble or other non-combustible finish material

Minimum 4 in. (102 mm) Cement Board or equivalent, (or two pieces HX4)

Minimum 20 in. (508mm) in front and 8 in. (203mm) on sides to fuel loading doors

Combustible Floor

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

. . .

. .

Non-combustible material supplied with unit.

. . .

. . .

. . .

. .

Non-combustible sealant or groutTile,marble or other non-combustible finish material

Figure 7.4 Fireplace and Hearth Extension Flush on the Floor.

• RaisedHearthExtensionFraming The hearth framing must be constructed of non-

combustible materials (such as metal framing orequivalentmaterial) and toppedwith twoHX4s, orequivalentmaterial(Table7.2).

When creating the platform, allow for the thickness of the non-combustible fi nishing materials (Figure7.5).

Outer Can Flange

Non-combustible material supplied with unit

Fascia

Protective metalhearth strip

Minimum 4 in. (102 mm) Cement Board or equivalent, (or two pieces HX4)

Minimum 20 in. (508 mm) in front and 8 in. (203 mm) on sides to fuel loading doors

Combustible Floor

Non-combustible sealant or groutTile,marble or other non-combustible finish material. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

. . .

. . .

. .

. . .

. . .

. . .

. .

Non-combustibleframing materials

Figure 7.5 Raised Hearth Extension to Bottom of Fascia

• Fireplaceinstalledflushonthefloorandhearthextensionraisedtobottomoffascia:

Non-combustibleflooringaminimumof20in.(508mm)infrontofand8in.(203mm)toeithersideofthefuelopeningisrequired(seeFigure7.3).

WARNING! Risk of Fire!

Hearth extensions are to be installed only as illustrated to prevent high tempertures from occurring on concealed combustible materials.

38 Quadra-Fire•7100FP•433-3610InstallationManual•RevF•3/25/14

Page 39: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

E. Non-Combustible Sealant Material• After completing the installation of non-combustible

materialintherequirednon-combustiblezoneandthenon-combustiblefinishingmaterialoverthat,removethetemplate.

• Abeadofnon-combustiblesealant(orSuperCalstick)mustbeusedtocloseoffanygapsatthetopandsidesbetween the fireplace and non-combustible facing(Figure7.6)topreventcoldairleaksandtheriskoffire.Largegapscanbebridgedwithfiberglassropegasket.

• Wheninstallationofthedecorativematerialiscomplete,replace/installthefasciaandfireplacedoors.

WARNING! Risk of Fire! • Maintainclearances. • Useonlynon-combustiblematerialbelowstandoffs,

material such as cement board is acceptable. • Framingorfinishingmaterialusedonthefrontof

thefireplacecloserthantheminimumslisted,mustbe constructed entirely of non-combustible materi-als (i.e., steel studs, concrete board, etc.).

WARNING! Risk of Fire! Hearth & Home Technologies is not responsible for

discoloration, cracking or other material failures of finishingmaterialsduetoheatexposureorsmoke.

• Choosefinishingmaterialscarefully.

Seal inside perimeter of fireplace finished opening with non-combustible grout to prevent risk of fire and cold air infiltration.

7100

45-1/4 in.(1150 mm)

47-1/2 in.(1207 mm)

NON-COMBUSTIBLE ZONE

Figure 7.6

39Quadra-Fire•7100FP•433-3610InstallationManual•RevF•3/25/14

Page 40: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

8 Fireplace Setup

A. Firebrick PlacementThefireboxofyourfireplaceislinedwithhighqualityfire-brick,whichhasexceptionalinsulatingproperties.

Donotuseagrate;simplybuildafireonthefireboxfloor.

Donotoperatethefireplacewithoutbricks.Makesurebricksareinstalledasshown.

IMPORTANT:Thebricksareverysimilarinsize.Becertainyouhavetheproperbrickinthecorrectlocation.Measurethebricksizeforaccuracy.

- Remove new brick set from box and lay out todiagramasshowninFigure8.2.

- Laybottombricksinfirebox.- Install rearbrickson the topof thebottombricks.

Slidetopofbricksundercliponbackoffireboxwallandpushbottomofbrickback.

- Installsidebricks.Slidetopofbrickunderclipsonsideoffireboxandpushthebottomofthebrickuntilitisflushwiththesideofthefirebox.

4

5 5 5 5 5 5

5

5

3

5 5 5 5 5

222224

5

5

5

3

11

5 5 5 5 5

5 5 5 5 5 11

4 2 2 2 2 2 4

5

5

5

3

5

5

5

3

Left Side Right SideBack

Floor

1-1/4"3-1/4"

9.0"

1

# BrickSize Qty.InSet1 9”x3-1/4”x1-1/4”Angled(see drawing) 22 6-1/4”x4-1/2”x1-1/4” 53 9”x2”x1-1/4” 24 6-1/4”x3-1/2”x1-1/4” 25 9”x4.5”x1-1/4” 16

Figure 8.1 Fire Brick Configurations

Figure 8.2 Fire Brick Configurations

Table 8.1

40 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 41: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

B. Baffle and Blanket PlacementEnsurecorrectbaffleandbaffleprotectionchannelplace-ment;replacebafflecomponentsifdamagedormissing.

TheceramicblanketandbaffleboardMUSTbeincontactwiththebackofthefireboxandevenwitheachotherinthe front.ThebaffleprotectionchannelMUSTbeinposi-tion.

Figure 8.3

Ceramic BlanketBack of Firebox

Baffle Board

BaffleProtectionChannelinposition

C. Install Fascia (Fronts)Frontsarerequiredtocompletetheinstallation.The7100fireplaceallowsachoiceoffronts,thereforetheyareshippedseparatelyfromthefireplaceduetocustomerpreferenceandselection.Instructionsforattachmentofthefrontsareincludedwiththem.Contactyourlocaldealerwithanyquestionsonofferingsorinstallation.

41Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 42: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

A. Chimney ComponentsThefollowingdrawingsshowtheSL-300Serieschimneyandfireplacecomponentswhichmaybesafelyusedwiththisfireplace.

ID4 Insulated Duct

UD4 Uninsulated Duct

42 in. (1067 mm)

4 in. (102 mm) i.d.

42 in.(1067 mm)

4 in. (102 mm) i.d.

8 in.(203 mm)

10-1/2 in.(267 mm)

A

B

10-1/2 in.(287 mm)

12 in.(305 mm)

5-1/4 in.(133 mm) 4 in. (102 mm)

12 in.(305 mm)

CAK4A Chimney Air Kit (shipped with fireplace)

Catalog #A B

in mm in mmSL306 6 152 4-3/4 121

SL312 12 305 10-3/4 273

SL318 18 457 16-3/4 425

SL324 24 610 22-3/4 578

SL336 36 914 34-3/4 883

SL348 48 1219 46-3/4 1187

9 Reference Materials

Catalog # DescriptionCAK4A ChimneyAirKit(shippedwithfireplace)

ID4 InsulatedDuct(usedwithchimneyairkit)

UD4 UninsulatedDuct(usedwthchimneyairkit)

SL306 ChimneySection-6in.(152mm)long

SL312 ChimneySection-12in.(305mm)long

SL318 ChimneySection-18in.(457mm)long

SL324 ChimneySection-24in.(610mm)long

SL336 ChimneySection-36in.(914mm)long

SL348 ChimneySection-48in.(1219mm)long

SL3 ChimneyStabilizer

SL315 ChimneyOffset/Return-15deg

SL330 ChimneyOffset/Return-30deg

FS338 CeilingFirestop-Straight

FS339 CeilingFirestop-15deg

FS340 CeilingFirestop-30deg

AS8 SL300StraightAtticInsulationShield,24in.(610mm)(shippedwithfireplace)

JB877 ChimneyJointBand

CB876 ChimneyBracket

RF370 RoofFlashing-Flatto6/12Pitch

RF371 RoofFlashing-6/12to12/12Pitch

DTO134/146 OctogonalDecorativeCaps

DTS134/146 SquareDecorativeCaps

ST375 SquareTerminationCap

TCT375 TerraCottaTerminationCap

TR344 RoundTerminationCap

TR342 RoundTelescopingTerminationCap

TR-TVK TRTopVentKit

TS345 SquareTerminationCap

TS345P SquareTerminationCap-Painted

TV342 TopVentRoundTerminationCap

12966A ManufacturedHomeThimble

MH841 ManufacturedHomeThimbleExtension20in./508mm

HX4 MicoreHearthExtension,20in./508mmwide

LDS33 DecorativeShroud-3ftx3ft(.91mx.91m)

LDS46 DecorativeShroud-4ftx6ft(1.22mx1.83m)

LDS-BV DecorativeShroud-26in.x26in.(660mmx660mm)

FieldConstructedShrouds(See“WoodburningTerminationCap”)

CT-3A Adapter-Maybeusedwiththefollowingcaps

CTSeries

DTSeries

Heat Zone WoodHHT - TemplateLintel Bar - HHT

42 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 43: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

RF370 - Roof Flashing Flat to 6/12 Pitch

RF371 - Roof Flashing 6/12 to 12/12 Pitch

Firestop Spacer

A=ActualLengthB=Effectivelength(lengthofchimneypart

afterithasbeensnappedtoanother)

A

B 14-1/2 in.(368 mm)

24-5/8 in.(625 mm)

27-3/8 in.(695 mm)

12 in.(305 mm)

31 in.(787 mm)

24-5/8 in.(625 mm)

12 in.(305 mm)

Catalog # A BFS338 0-deg. 14-1/2in. 368mm

FS339 15-deg. 18-3/8in. 467mm

FS340 30-deg. 23in. 584mm

20-3/4 in.(527 mm)

InsideDiameter

8 in.(203 mm)

OutsideDiameter10-1/2 in.(267 mm)

4-3/4 in. (121 mm)Effective Height

SL3 Chimney Stabilizer

Inside Diameter8 in. (203 mm)

Outside Diameter10-1/2 in.(267 mm)

SL315 Chimney Offset/Return - 15 deg.SL330 Chimney Offset/Return - 30 deg.

AS8 SL300 Straight Attic Insulation Shield (shipped with unit)

2 in. (51 mm)

10-1/2 in.(267 mm)

JB877 Chimney Joint Band

10-1/2 in.(267 mm)

CB876 Chimney Bracket

MH841 Manufactured Home Thimble Extension

24-5/8 in.(625 mm)

16-5/8 in.(422 mm)

29 in.(737 mm)

16-5/8 in.(422 mm)

12966A Manufactured Home Thimble

AssembledDiameter: 14 1/2 in./368 mm

Height: 24 in./610 mm

43Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 44: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

20 in.(508 mm)

66 in.(1676 mm)

1/2 in.(13 mm)

HX4 Micore Hearth Extension

B

A

C

B

C

A

DTS134/DTS146 DTO134/DTO146Decorative Caps

DTO134 A B Cin 34 20 24mm 864 508 610

DTO146in 46 22.7 26mm 1168 576 660

DTS134 A B Cin 34 21.18 24mm 864 538 610

DTS146in 46 21.18 26mm 1168 538 660

23 in.(584 mm)

19 in.(483 mm)

15-5/8 in.(397 mm)

ST375 Square Termination Cap

22 1/2 in.(572 mm)

9 1/2 in.(241 mm)

16 1/2 in.(419 mm)

9 1/2 in.(241 mm)

TCT375 Terra Cotta Termination Cap

34-3/4 in.(883 mm)

32-1/2 in.(826 mm)

TR342 Round Telescoping Termination Cap

15-3/4 in.(400 mm)

TR344 Round Termination Cap

44 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 45: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

TR-TVK Top Vent Kit

13 1/4 in.(337 mm)

18 in. (457 mm)

16 1/4 in.(413 mm)

26 1/2 in.(673 mm)

28 5/8 in.(727 mm)

TS345 Square Termination CapTS345P Painted Square Termination Cap

32 in.(813 mm)

34-1/4 in.(870 mm)

TV342 Top Vent Round Termiantion Cap

A

B

C

D

Catalog #A B C D

in. mm in. mm in. mm in. mmLDS33 36 914 36 914 8.5 216 11 279

LDS46 48 1219 72 1829 8.5 216 11 279

LDS33/LDS46 Decorative Shroud

Catalog # A B C D E

LDS-BVin. 26 12.5 15.5 22 23

mm 660 318 394 533 584

ED

A

CB

LDS-BV Decorative Shroud

26 in.

7 3/4 in.

CT-3A Adapter

45Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 46: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

B. Accessories

MESH-HHT FirescreenDoors: Classic Black Gold Satin NickelFronts: Valley Forge Mission Hill Rolling Meadow

46 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 47: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

This page intentionally left blank.

47Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14

Page 48: 433-3610F 7100 Installer Manual 11-18-13 WIP...shown) must be used with SL300 chimney Protective metal hearth strip(s) A. Typical Fireplace System Figure 2.1 Typical Fireplace System

Quadra-Fire,abrandofHearth&HomeTechnologies7571215thStreetWest,Lakeville,MN55044

www.quadrafire.com

PleasecontactyourQuadra-Firedealerwithanyquestionsorconcerns.ForthelocationofyournearestQuadra-Firedealer,pleasevisitwww.quadrafire.com.

48 Quadra-Fire • 7100 FP • 433-3610 Installation Manual • Rev F • 3/25/14