42701 0441 SPECTRALEAF Elizabethtown, KYREINFORCING STEEL - ASTM A615 GRADE 60 (UNLESS WELDED). 3....

40
PROJECT DATE CHECKED DRAWN S T A M P HERE ( N O T FO R CO N ST RU CTIO N ) REMOVE BEFORE PRINTING REMOVE BEFORE PRINTING REVISIONS 35 Public Square Elizabethtown, KY 42701 Office: (270) 737 - 4226 Fax: (270) 737 - 0441 [email protected] ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC. THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC. G - 000 COVER SHEET 2019 - 1576 Author Checker 8/23/2019 95% REVIEW DOCS SPECTRALEAF 170 BUDCO LANE ELIZABETHTOWN, KY 42701 GENERAL SPECTRALEAF 170 BUDCO LANE ELIZABETHTOWN, KY 42701 95% REVIEW DOCS 08/23/19 No. Description Date

Transcript of 42701 0441 SPECTRALEAF Elizabethtown, KYREINFORCING STEEL - ASTM A615 GRADE 60 (UNLESS WELDED). 3....

  • PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    MO

    VE

    BE

    FO

    RE

    PR

    INT

    ING

    RE

    MO

    VE

    BE

    FO

    RE

    PR

    INT

    ING

    RE

    VIS

    ION

    S

    35

    Pu

    bli

    c S

    qu

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    427

    01

    Off

    ice:

    (27

    0)

    73

    7-4

    22

    6 •

    Fa

    x:

    (270

    ) 73

    7-0

    44

    1

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    G-000

    COVER SHEET

    2019-1576

    Author

    Checker

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    GENERAL

    SPECTRALEAF

    170 BUDCO LANE

    ELIZABETHTOWN, KY 42701

    95% REVIEW DOCS

    08/23/19

    No.

    Description

    Date

  • Z:\projects\misc-dp\ICON-LOT5-SOUTHEND-SPECTRALEAF\LOT5-SOUTHEND-BASE.dwg, 8/22/2019 2:40:03 PM, DWG To PDF.pc3

  • FORTERRA

    Z:\projects\misc-dp\ICON-LOT5-SOUTHEND-SPECTRALEAF\LOT5-SOUTHEND-BASE.dwg, 8/22/2019 2:39:09 PM, DWG To PDF.pc3

  • TYPICAL CLEANOUT DETAIL DRAWN BY: M. PAGEDATE: 11/06/17

    Wye Branch Fitting

    Z:\projects\misc-dp\ICON-LOT5-SOUTHEND-SPECTRALEAF\LOT5-SOUTHEND-BASE.dwg, 8/22/2019 1:48:22 PM, DWG To PDF.pc3

  • Z:\projects\misc-dp\ICON-LOT5-SOUTHEND-SPECTRALEAF\LOT5-SOUTHEND-BASE.dwg, 8/22/2019 1:52:30 PM, DWG To PDF.pc3

  • SHOP DRAWINGS:

    SHOP DRAWINGS ARE AN AID FOR FIELD PLACEMENT AND ARE SUPERSEDED BY THE STRUCTURAL DRAWINGS. ANY REVIEW OF SHOP DRAWINGS BY THIS OFFICE IS ONLY FOR GENERAL CONFORMANCE TO THE STRUCTURAL REQUIREMENTS AND IN NO WAY GUARANTEES THE ACCURACY OR COMPLETENESS OF INFORMATION THEREON. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO INSURE ALL CONSTRUCTION IS IN FULL COMPLIANCE WITH THE LATEST SET OF STRUCTURAL DRAWINGS. SHOP DRAWINGS MAY NOT BE BASED ON CONTRACT DRAWINGS. ALL SHOP DRAWINGS WHICH HAVE NOT BEEN PREPARED FROM SCRATCH WILL BE REJECTED. SUBMIT ELECTRONIC COPY FOR REVIEW. REVIEW SET WILL BE RETURNED WITH ANY COMMENTS ELECTRONICALLY IN PDF FORM.

    GEOTECHNICAL REPORT:

    REFERENCE SHOULD BE MADE TO GEOTECHNICAL INVESTIGATION REPORT PREPARED BY:NAMEADDRESSADDRESSDATED

    IT IS RECOMMENDED THAT THE GEOTECHNICAL ENGINEER BE RETAINED TO PROVIDE OBSERVATION AND TESTING SERVICES DURING THE GRADING AND FOUNDATION PHASEOF CONSTRUCTION. INSPECTION AND TESTING REPORTS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER.

    FOUNDATION NOTES:

    1. THE FOUNDATIONS HAVE BEEN DESIGNED BASED ON RECOMMENDATIONS CONTAINED IN THE GEOTECHNICAL INVESTIGATION REPORT PREPARED BY NAME, DATED

    2. SPREAD AND STRIP FOOTINGS HAVE BEEN DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 PSF AT 36 INCHES BELOW GRADE.

    3. PROTECT EXISTING UTILITIES AND STRUCTURES, OVERHEAD OR UNDERGROUND, IN WORK AREA.

    4. PROTECT EXISTING FOOTING. THE CONTRACTOR IS RESPONSIBLE FOR ANY TEMPORARY SHORING OR BRACING.

    CONCRETE NOTES:

    1. CONCRETE STRENGTH - PROVIDE CONCRETE WITH THE FOLLOWING STRENGTHS AT THE LOCATIONS NOTED. MIX DESIGN, SLUMP, AIR ENTRAINMENT, AGGREGATE SIZE, ETC., SHALL BE IN CONFORMANCE WITH THE A.C.I. CODE, LATEST EDITION.

    LOCATION STRENGTH (PSI @ 28 DAYS)

    SPREAD FOOTINGS, SLABS-ON-GRADE 4,000 PSI NORMAL WEIGHT

    2. REINFORCING STEEL - ASTM A615 GRADE 60 (UNLESS WELDED).

    3. WELDING OF REINFORCING STEEL SHALL CONFORM TO AWS D12-1 USING PROPER LOW HYDROGEN ELECTRODES. ALL BARS TO BE WELDED SHALL CONFORM TO ASTM A706.

    4. FABRICATE AND PLACE REINFORCEMENT IN ACCORDANCE WITH ACI PUBLICATION SP-66, ACI DETAILING MANUAL - LATEST EDITION.

    5. PLACE CONCRETE IN COMPLIANCE WITH ACI 304. ALL CONCRETE SHALL BE MECHANICALLY VIBRATED.

    6. CONCRETE COVER FOR REINFORCEMENT FOR NON-PRESTRESSED, CAST IN PLACE CONCRETE SHALL BE AS FOLLOWS:

    CONDITION COVER

    CAST AGAINST EARTH 3" EXPOSED TO WEATHER #5 & SMALLER 1 1/2" #6 & LARGER 2" SLAB-ON-GRADE 2"

    7. EMBEDS - ALL ITEMS TO BE CAST INTO CONCRETE SUCH AS REINFORCING DOWELS, BOLTS, ANCHORS, PIPES, SLEEVES, ETC., SHALL BE SECURELY AND ACCURATELY POSITIONED INTO THE FORMS PRIOR TO PLACING THE CONCRETE.

    8. CONSTRUCTION JOINTS - THE CONTRACTOR SHALL OBTAIN THE ENGINEER'S APPROVAL FOR CONCRETE CONSTRUCTION JOINT LOCATIONS. REINFORCING STEEL DETAILING MAY CHANGE AND THE CONTRACTOR MAY BE RESPONSIBLE FOR ADDITIONAL EXPENSES AS A RESULT.

    STRUCTURAL STEEL NOTES:

    1. MATERIAL - ALL MATERIAL SHALL BE IN ACCORDANCE WITH THE FOLLOWING ASTM DESIGNATIONS UNLESS NOTED OTHERWISE:

    WIDE FLANGE SHAPES A992CHANNELS, PLATES & BARS A36STEEL TUBES A500 GRADE CANGLES A36ANCHOR RODS F1554 GRADE 36

    2. WELDING - PERFORM ALL WELDING IN ACCORDANCE WITH 2000 AWS D1.1 CODE. WELDS SHALL BE MADE ONLY BY OPERATORS CERTIFIED BY AWS IN PERFORMING THE TYPE OF WORK INDICATED.

    3. WELDING CONSUMABLES - WELD CONSUMABLES SHALL HAVE YIELD & TENSILE STRENGTH EQUAL TO OR SLIGHTLY GREATER THAN THE EXPECTED YIELD & TENSILE STRENGTH OF STEEL MEMBER BEING WELDED.

    4. BOLTING - ALL BOLTED CONNECTIONS SHALL CONFORM TO THE RCSC - "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" DATED JUNE 23, 2000. ALL BOLTS SHALL BE 3/4" DIA. ASTM A325-N UNLESS NOTED OTHERWISE.

    5. PAINTING - AFTER MATERIAL HAS BEEN PROPERLY CLEANED (SP3), APPLY TWO SHOP COATS OF STANDARD GRAY PRIMER TO ALL SURFACES, EXCEPT THOSE INTENDED FOR EMBEDMENT INTO CONCRETE OR TO RECEIVE FIELD WELDING, SLIP CRITICAL BOLTS.

    6. FABRICATION - ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL BE FABRICATED AND ERECTED IN ACCORDANCE WITH AISC SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, IN ADDITION TO THE AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS & BRIDGES - LATEST EDITIONS.

    DESIGN CRITERIA:

    BUILDING CODE:2018 KENTUCKY BUILDING CODE

    2ND FLOOR DEAD LOADS:FIRE TREATED 3/4" T&G SUB-FLOOR 2 PSFFRAMING SELF WEIGHT 5 PSFCEILING, MECH & ELECT 5 PSF

    2ND FLOOR LIVE LOADS:FUTURE OFFICE USE 50 PSFPARTITION LOADING 15 PSFCOORIDOR 80 PSFLANDING AND STAIRS 100 PSF

    SEE PEMB DRAWINGS FOR ALL OTHER BUILDING LOADINGS AND CRITERIA

    CONNECTION DESIGN NOTES:

    1. CONNECTION DESIGN MUST BE SUBMITTED FOR REVIEW IN A CLEAR EASILY UNDERSTOOD MANNER, PREFERABLY IN MATHCAD FORMAT. CONNECTION DESIGN SUBMITTALS MUST BE COMPLETE AND REVIEWED PRIOR TO SHOP DRAWING PREPARATION TO ENSURE CONNECTION DESIGN IS PROPERLY DETAILED. SHOP DRAWINGS THAT DO NOT INCORPORATE REVIEWED CONNECTION DESIGNS WILL NOT BE REVIEWED AND WILL BE RETURNED AS "REJECTED".

    2. SIMPLE SHEAR CONNECTIONS SHALL BE DESIGNED FOR THE FORCES SHOWN ON PLAN. SUGGESTED DETAILS ARE PROVIDED IN THE TYPICAL DETAILS. CONNECTION ENGINEER IS RESPONSIBLE FOR CARRYING OUT DESIGN. DEVIATIONS FROM SUGGESTED CONNECTIONS MUST BE APPROVED BEFORE CONNECTION DESIGN IS SUBMITTED FOR REVIEW.

    3. EDGE DISTANCE AND BOLTS SPACING SHALL BE PER AISC SPECIFICATIONS.

    HIGH STRENGTH BOLTS (H.S.B.):

    1. HIGH STRENGTH BOLTS SHALL CONFORM TO THE PROVISIONS OF THE "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS", LATEST EDITION, AS APPROVED BY THE RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS, & THE PROVISIONS OF THE K.B.C.

    2. THE ASSEMBLY SURFACE, INCLUDING THOSE ADJACENT TO THE WASHER, SHALL BE FREE OF MILL SCALE, OIL, PAINT, OR OTHER COATINGS.

    3. ALL HIGH STRENGTH BOLTS SHALL BE TIGHTENED TO A BOLT TENSION NOT LESS THAN THAT SPECIFICATION IN THE AISC MANUAL. FULL TENSIONING SHALL BE BY THE TURN OF THE NUT METHOD, BY A DIRECT TENSION INDICATOR, OR BY PROPERLY CALIBRATED WRENCHES. PROVIDE HARDENED WASHERS UNDER THE NUT OR BOLT HEAD, WHICHEVER IS THE ELEMENT TURNED IN TIGHTENING.

    GENERAL NOTES:

    1. TYPICAL NOTES & DETAILS ARE PROVIDED TO COVER GENERAL CONSTRUCTION CONDITIONS. THE CONTRACTOR SHALL FOLLOW THOSE DETAILS & NOTES PERTAINING TO THE SPECIFIC NATURE OF THE WORK TO BE PERFORMED.

    2. NOTES & DETAILS ON THESE STRUCTURAL DRAWINGS SHALL APPLY UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE. DETAILS ARE SHOWN IN DIAGRAMMATIC FORM AND ARE NOT TO BE SCALED (SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS, ELEVATIONS, SLOPES, FINISHES, ETC.). CONSTRUCTION DETAILS NOT SHOWN OR NOTED SHALL BE SIMILAR TO DETAILS SHOWN FOR SIMILAR CONDITIONS. ALL WORK OR CONSTRUCTION SHALL COMPLY WITH THE CURRENT BUILDING CODE AND ALL OTHER APPLICABLE REGULATIONS & SAFETY REQUIREMENTS.

    3. DISCREPANCIES - IN THE EVENT OF A DISCREPANCY IN THE STRUCTURAL CONSTRUCTION DOCUMENTS, THE NOTE OR DETAIL UTILIZING THE STRICTER REQUIREMENT SHALL APPLY.

    4. EXCAVATION, SHORING, & BRACING - IT SHALL BE THE CONTRACTOR'S SOLE RESPONSIBILITY TO DESIGN AND PROVIDE ADEQUATE SHORING, BRACING, FORM WORK, ETC., AS REQUIRED FOR PROTECTION OF LIFE & PROPERTY, TO SUPPORT ANY CONSTRUCTION LOADS, AND TO MAINTAIN ALL BUILDING COMPONENTS SAFELY IN PLACE PRIOR TO THEIR FINAL ASSEMBLY AND ANCHORAGE INTO THE COMPLETED STRUCTURE.

    5. INSPECTIONS - ALL INSPECTION AND TESTING SHALL BE PERFORMED ACCORDING TO BUILDING CODE AND/OR MORE STRINGENT REQUIREMENTS OF THESE PLANS.

    6. COORDINATION - REFER TO THE ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND ALL OTHER PERTINENT DRAWINGS FOR THE SIZE AND LOCATION OF PIPE, VENT, DUCT, AND OTHER OPENINGS & DETAILS NOT SHOWN ON THESE STRUCTURAL DRAWINGS. ALL DIMENSIONS SHALL BE CHECKED & COORDINATED BY THE CONTRACTOR.

    7. SHOP DRAWINGS ARE AN AID FOR FABRICATION & INSTALLATION, AND ARE SUPERSEDED BY THE STRUCTURAL DRAWINGS. THE GENERAL CONTRACTOR IS RESPONSIBLE TO MAKE CERTAIN THAT ALL CONSTRUCTION IS IN FULL AGREEMENT WITH THE LATEST STRUCTURAL DRAWINGS. SHOP DRAWING REVIEWS BY THE STRUCTURAL ENGINEER ARE FOR GENERAL CONFORMANCE WITH THE STRUCTURAL DRAWINGS AND DO NOT GUARANTEE THAT THE SHOP DRAWINGS ARE CORRECT.

    STATEMENT OF SPECIAL INSPECTIONS

    IN ACCORDANCE WITH THE 2013 KENTUCKY BUILDING CODE, THE OWNER WILL EMPLOY AN APPROVED INDEPENDENT INSPECTION/TESTING AGENCY AS DEFINED IN SECTION 1704 TO PERFORM INSPECTIONS DURING CONSTRUCTION ON THE TYPES OF WORK LISTED UNDER SECTION 1705. THE SPECIAL INSPECTION AGENCY WILL PROVIDE TESTING AND INSPECTION REPORTS TO THE STRUCTURAL ENGINEER OF RECORD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING AND/OR CORRECTING DEFICIENCIES AS IDENTIFIED BY THE AGENCY. THE CONTRACTOR SHALL COORDINATE WITH THE AGENCY FOR ALL REQUIRED INSPECTIONS AND TESTING. REPORTS WILL BE PROVIDED FOR EACH DAYS INSPECTION. ALL NONCONFORMING ITEMS WILL BE BROUGHT TO THE CONTRACTORS ATTENTION, AND WILL BE RECORDED ON THE INSPECTION REPORT.

    DELEGATED DESIGN OF BUILDING COMPONENTS:

    1. DESIGN OF CERTAIN BUILDING COMPONENTS THAT ARE NOT CONSIDERED PART OF THE PRIMARY STRUCTURAL SYSTEM IS DELEGATED TO BE COMPLETED BY A SPECIALTY STRUCTURAL ENGINEER RETAINED BY THE CONTRACTOR. THESE COMPONENTS MAY INCLUDE BUT ARE NOT LIMITED TO STAIRS, COLD-FORMED STEEL FRAMING, PREENGINEERED TRUSSES, ARCHITECTURAL AND STRUCTURAL HEAVY TIMBER, HEAVY TIMBER DECKING, AND DESIGNATED EQUIPMENT SUPPORTS. THE DESIGN SHALL INCLUDE THE CONNECTIONS TO THE PRIMARY BUILDING FRAME WHERE APPLICABLE.

    2. THE SPECIALTY STRUCTURAL ENGINEER SHALL DESIGN THE COMPONENT(S) AND ASSOCIATED CONNECTIONS, FOR THE LOADS AND DEFLECTION REQUIREMENTS INDICATED. THE REVIEW OF THE SHOP DRAWING SUBMITTAL BY THE STRUCTURAL ENGINEER SHALL ONLY BE TO VERIFY COMPLIANCE WITH DESIGN INTENT, APPLICATION OF LOADS SPECIFIED, AND REVIEW OF THE PRIMARY BUILDING FRAME TO RESIST THE LOADS IMPOSED BY THE COMPONENT CONNECTIONS.

    COLD-FORMED STEEL (CFS) FRAMING:

    1. ALL STRUCTURAL MEMBERS SHALL CONFORM TO THE AISI "SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS," LATEST EDITION.

    2. ALL COLD-FORMED METAL STUDS AND/OR JOISTS AND ACCESSORIES SHALL BE OF THE TYPE, SIZE, AND MINIMUM GAGE INDICATED.

    3. A SPECIALTY STRUCTURAL ENGINEER LICENSED IN THE PROJECT STATE SHALL DESIGN THE CURTAIN WALL FRAMING INCLUDING THE ANCHORAGE TO THE PRIMARY STRUCTURAL FRAME AND SHALL PROVIDE SEALED CALCULATIONS AND SEALED SHOP DRAWINGS.

    4. ALL STRUCTURAL MEMBERS SHALL BE FORMED FROM ZINC COATED STEEL, CORRESPONDING TO THE REQUIREMENTS OF ASTM A653, WITH A MINIMUM COATING OF G60.

    5. STUDS SHALL BE CUT SQUARE AND PLACED TIGHT TO TRACKS WITH NO GAPS, EXCEPT AT DEFLECTION TRACK/CLIP LOCATIONS ABOVE NON-BEARING PARTITIONS.

    6. THE FRAMING INSTALLER IS TO ENSURE PUNCHOUT ALIGNMENT WHEN ASSEMBLING LATERAL BRACING AND FIELD CUTTING STUDS TO LENGTH. LATERAL BRACING MUST BE INSTALLED AT THE TIME OF WALL ERECTION.

    7. FASTENING OF COMPONENTS SHALL BE WITH SELF-DRILLING SCREWS OF SUFFICIENT SIZE TO ENSURE THE STRENGTH OF THE CONNECTION. WIRE TYING OF COMPONENTS IS NOT PERMITTED. SPLICES IN FRAMING COMPONENTS OTHER THAN THE RUNNER TRACK ARE NOT PERMITTED.

    8. CURTAIN WALL FRAMING SHALL COMPLY WITH THE FOLLOWING:

    A. STUDS SHALL BE AS REQUIRED BY DESIGN BUT NOT LESS THAN 18 GAGE. HEAVIER GAGE STUDS AND/OR REDUCED STUD SPACING AT BUILDING CORNERS MAY BE NECESSARY AS REQUIRED BY DESIGN TO ACCOMMODATE END-ZONE WIND PRESSURES.

    B. INSTALLATION OF CURTAIN WALL FRAMING SHALL ACCOMMODATE DEFLECTION OF PRIMARY STRUCTURAL FRAMING USING DEFLECTION CLIPS AS INDICATED. DESIGN FRAMING SYSTEM TO ACCOMMODATE UPWARD AND DOWNWARD MOVEMENT OF PRIMARY STRUCTURE AS INDICATED.

    C. CURTAIN WALL FRAMING SHALL BE DESIGNED FOR HORIZONTAL WIND PRESSURES PER THE GOVERNING BUILDING CODE FOR COMPONENTS AND CLADDING LOADING. DESIGN CURTAIN WALL FRAMING TO ACCOMMODATE HORIZONTAL DEFLECTION WITHOUT REGARD FOR CONTRIBUTION OF SHEATHING MATERIALS.

    D. LIMIT OUT-OF-PLANE DEFLECTION TO H/600 AT WALLS WITH MASONRY VENEER, OR H/480 AT WALLS WITH NON-MASONRY VENEER.

    E. CURTAIN WALL FRAMING SHALL BE DESIGNED TO INCLUDE THE WEIGHT OF ALL WALL FINISH MATERIALS.

    NEED

    GEO

    TECH

    NICA

    L ST

    UDY

    REPO

    RT

    SPEC

    IAL

    INSP

    ECTI

    ON C

    HART

    S TO

    BE

    ADDE

    D

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35

    Pu

    bli

    c S

    qu

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    427

    01

    Off

    ice:

    (27

    0)

    73

    7-4

    22

    6 •

    Fa

    x:

    (270

    ) 73

    7-0

    44

    1

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    S-000

    GENERAL

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    STRUCTURAL

    No.

    Description

    Date

  • APPLICABLE CODES(KENTUCKY-2018)

    LIFE SAFETY

    2013 KENTUCKY BUILDING CODE (KBC) (815 KAR 7:120)(MODEL CODE: 2012 INTERNATIONAL BUILDING CODE)

    2012 INTERNATIONAL FIRE CODE(NEW CONSTRUCTION IN BUILDINGS WHERE SPECIFICALLY REFERENCED IN THE KBC, ONLY)

    ACCESSIBILITY

    CHAPTER 11 - ACCESSIBILITY(2013 KENTUCKY BUILDING CODE)

    ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES(ICC/ANSI A117.1, 2009 EDITION)

    PLUMBING

    KENTUCKY STATE PLUMBING LAW, REGULATIONS AND CODE(815 KAR CHAPTER 20)

    FUEL GAS

    NATIONAL FUEL GAS CODE(MODEL CODE: 2009 NFPA 54)

    MECHANICAL

    2012 INTERNATIONAL MECHANICAL CODE

    ELECTRICAL

    NATIONAL ELECTRICAL CODE(MODEL CODE: 2014 NFPA 70)

    ENERGY

    2012 INTERNATIONAL ENERGY CONSERVATION CODE(COMCHECK PER ASHRAE 90.1-2010)

    CODE REQUIREMENTS FOR OCCUPANCIES:

    1. THE ENTIRE BUILDING IS CONSIDERED AN "M" OCCUPANCY. (KBC-309.1)

    CODE REQUIREMENTS FOR HEIGHT AND AREA:

    1. THE BUILDING HAS 100 PERCENT OF ITS PERIMETER ON A PUBLIC WAY OR OPEN SPACE HAVING WIDTH OF NOT LESS THAN 20 FEET. (KBC-506.2)2. NO INCIDENTAL USES EXIST WITHIN THE BUILDING. (KBC-509, TABLE 509)

    CODE REQUIREMENTS FOR CONSTRUCTION TYPE:

    1. THE ENTIRE BUILDING IS CONSIDERED A "II-B" CONSTRUCTION TYPE. (KBC-602.2, TABLE 601)

    CODE REQUIREMENTS FOR FIRE RATINGS:

    1. BUILDING ELEMENTS. NO RATINGS REQUIRED. (KBC-TABLE 601, 704.1)2. EXTERIOR WALLS. NO RATINGS REQUIRED. ALL FIRE SEPARATION DISTANCES EXCEED 30' MINIMUM. (KBC-TABLE 602, 705.2.1, 705.5)3. EXTERIOR WALL OPENINGS. NO RATINGS OR PROTECTIONS REQUIRED. ALL FIRE SEPARATION DISTANCES EXCEED 30' MINIMUM. (KBC-TABLE 705.8) 4. FIRE WALLS NONE REQUIRED. NOT APPLICABLE. (KBC-706)5. FIRE BARRIERS. NONE REQUIRED. NOT APPLICABLE. (KBC-707)6. FIRE PARTITIONS. NONE REQUIRED. NOT APPLICABLE. (KBC-708)7. SMOKE BARRIERS. NONE REQUIRED. NOT APPLICABLE. (KBC-709)8. SMOKE PARTITIONS. NONE REQUIRED. NOT APPLICABLE. (KBC-710)9. HORIZONTAL ASSEMBLIES. NONE REQUIRED. NOT APPLICABLE. (KBC-711)10. VERTICAL OPENINGS. NONE REQUIRED. NOT APPLICABLE. (KBC-712) 11. SHAFT ENCLOSURES. NONE REQUIRED. NOT APPLICABLE. (KBC-713)12. PENETRATIONS. NONE REQUIRED. NOT APPLICABLE. (KBC-714) 13. JOINT SYSTEMS. NONE REQUIRED. NOT APPLICABLE. (KBC-715)14. OPENING PROTECTIVES. NONE REQUIRED. NOT APPLICABLE. (KBC-716)

    CODE REQUIREMENTS FOR FIRE SPRINKLER:

    CODE REQUIREMENTS FOR FIRE ALARM/DETECTION:

    1. A FIRE SPRINKLER SYSTEM IS NOT REQUIRED FOR THIS "M" OCCUPANCY. (KBC-903.2.7)

    1. A FIRE ALARM AND DETECTION SYSTEM IS NOT REQUIRED FOR THIS "B" OCCUPANCY. (KBC-907.2.7)

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35

    Pu

    bli

    c S

    qu

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    427

    01

    Off

    ice:

    (27

    0)

    73

    7-4

    22

    6 •

    Fa

    x:

    (270

    ) 73

    7-0

    44

    1

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    G-001

    CODES

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    GENERAL

    No.

    Description

    Date

    1R

    evis

    ion

    1D

    ate

    1

    TO BE EDITED

  • 1 2 3 4 5

    A

    B

    C

    D

    BP-C

    BP-B

    BP-A

    BP-DBP-D BP-D BP-A

    BP-FBP-F

    BP-C

    BP-C

    BP-ABP-EBP-EBP-E

    BP-A

    25' - 0" 25' - 0" 25' - 0" 25' - 0"

    1

    S-300

    2

    S-300

    3

    S-300

    60' -

    0"

    20' -

    0"

    20' -

    0"

    20' -

    0"

    11 3

    /4"

    11 3

    /4"

    1 1

    /2"

    1 1

    /2"

    1 1

    /2"

    1 1

    /2"

    1 1/2"

    1 1/2"

    F1 F1 F1

    F1 F1 F11' - 0"

    5"

    1' - 0"

    1' - 0"

    2' - 6"

    4

    S-300

    1

    S-301

    RECOMMENDED CONTROL JOINT LAYOUT

    2

    S-300

    2

    S-300

    2' - 0" 7' - 11 7/8"

    12" THICKENED SLABWITH 3)#5 CONTINUOUS

    AND #5 CROSS BARS AT 12" O.C.

    6' - 0

    " TY

    PIC

    AL

    HAIR PIN BAR, TYPICAL

    5" 4,000PSI SLAB OVER 10MIL REINFORCED TAPED/SEALED VAPOR BARRIER OVER 6"CLEAN COMPACTED #57 CRUSHED STONE

    F2

    F2

    F2

    F2 F2

    F2

    F2

    F2

    S-1019

    S-1018

    S-10110

    S-10111

    S-10112

    6' -

    4"

    6' - 4"

    S-10113

    HSS

    3-1/

    2X3-

    1/2X

    1/4

    HSS

    3-1/

    2X3-

    1/2X

    1/4

    LAN

    DIN

    G S

    UPP

    OR

    T C

    OLU

    MN

    LAN

    DIN

    G S

    UPP

    OR

    T C

    OLU

    MN

    RE-ENTY BARSTYPICAL AT PIERS

    POUR THROUGH AT DOOR,TYPICAL

    HS

    S6X

    3X

    3/1

    6(E

    L: 100' -

    0")

    5" Foundation Slab

    97' - 6"

    TYPICAL

    97' - 6"

    6

    A-305

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    S-100

    FOUNDATION

    PLAN

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    STRUCTURAL

    A-300 SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN

    No.

    Descriptio

    nD

    ate

    FOOTING SCHEDULE

    MARK LENGTH WIDTH DEPTH REINFORCEMENT

    F1 5' - 0" 4' - 0" 1' - 0" 4)#5 LONG T/B, 5)#5 SHORT T/B - STANDARD HOOK ONTOP BARS

    F2 3' - 0" 3' - 0" 1' - 0" 4)#5 EACH WAY

    SF1 60' - 3" 2' - 6" 1' - 0" 3)#5 CONTINUOUS WITH #5@12" CROSS BARS. RUNCONTINUOUS BARS THROUGH COLUMN FOOTINGS

  • 2 1/2" 3"

    6"

    8"

    Ø5/8" ANCHOR RODS

    11 3

    /4"

    1 1

    /2"

    1 1/2"

    1 3

    /4"

    1 3

    /4"

    4"

    2 1/2" 3"

    1 3

    /4"

    1 3

    /4"

    6"

    8 1/2"

    Ø5/8" ANCHOR RODS

    SE

    E P

    LA

    N

    1 1/2"

    4"

    2 1/2" 3"

    1 3

    /4"

    1 3

    /4"

    6"

    8"

    Ø5/8" ANCHOR RODS

    1 1/2"

    SE

    E P

    LA

    N

    4"

    1 3/4" 1 3/4"

    2 1

    /2"

    3"

    2' -

    0 1

    /2"

    6"

    Ø3/4" ANCHOR RODS

    1 1

    /2"

    8 1

    /4"

    SEE PLAN

    SIDE WALL

    1' -

    0 1

    /4"

    1 3/4" 1 3/4"

    2 1

    /2"

    3"

    1' -

    7"

    6"

    Ø3/4" ANCHOR RODS

    SIDE WALL

    8 1

    /4"

    SEE PLAN

    1 1

    /2"

    1' -

    0 1

    /4"

    SIDE WALL

    SEE PLAN

    3 1/2"

    1 3/4"

    3"

    Ø5/8" ANCHOR RODS

    1 1

    /2"

    2 1

    /2"

    SEE PLAN

    4"

    EN

    D W

    ALL

    SE

    E P

    LA

    N

    3 1

    /2"

    1 3

    /4"

    3"

    Ø5/8" ANCHOR RODS

    1 1/2"2 1/2"

    4"

    3

    D

    3"

    1' -

    0 1

    /4"

    OUTSIDE FACE OF GRADE BEAM

    1 1/2"X1 1/2" NOTCH FORWALL PANEL

    6)#6 VERTICAL

    9 1

    /2"

    2' -

    3 1

    /2"

    PEMB BASE PLATE

    4) 3/4" F1554 GR36 ANCHOR RODS WITH 18" EMBEDMENT AND 3" PROJECTION. PROVIDE NUT & LARGE hd WASHER TACK WELDED BOTTOM

    4 1/4" 3 1/2"

    4)#4 TIES WITH 2 AT TOP

    4)#4 DOWELS AT TIE SPACING

    3' -

    3"

    5' -

    0"

    4' - 0"

    #5 HAIRPIN BAR

    4

    A

    OUTSIDE FACE OF GRADE BEAM

    1 1/2"X1 1/2" NOTCH FORWALL PANEL

    6)#6 VERTICAL

    PEMB BASE PLATE

    4) 3/4" F1554 GR36 ANCHOR RODS WITH 18" EMBEDMENT AND 3" PROJECTION. PROVIDE NUT

    & LARGE hd WASHER TACK WELDED BOTTOM

    4)#4 TIES WITH 2 AT TOP

    4)#4 DOWELS AT TIE SPACING

    5' -

    0"

    4' - 0"

    1' -

    0 1

    /4"

    3"

    4 1/4" 3 1/2"

    #5 HARPIN BAR

    5

    A

    5"

    2' -

    7"

    3' -

    0"

    3' - 0"

    2' - 0" 1' - 0"

    OUTSIDE FACE OF GRADE WALL

    PEMB BASE PLATE

    4) 3/4" F1554 GR36 ANCHOR RODS WITH 12" EMBEDMENT AND 3"

    PROJECTION. PROVIDE NUT & LARGE HD WASHER TACK WELDED BOTTOM

    4)#6 VERTICAL

    4)#4 TIES WITH 2 AT TOP

    5

    B

    1' - 0"

    3' - 0"

    9 1/2"

    3' -

    0"

    OUTSIDE FACE OF GRADE WALL

    1 1/2"X1 1/2" NOTCH FORWALL PANEL

    PEMB BASE PLATE

    4) 3/4" F1554 GR36 ANCHOR RODS WITH 12" EMBEDMENT AND 3"

    PROJECTION. PROVIDE NUT & LARGE HD WASHER TACK WELDED BOTTOM

    4)#6 VERTICAL

    4)#4 TIES WITH 2 AT TOP

    1 1/2"

    #5 HAIR PIN BAR

    1

    D

    2' - 6"

    7" 1' - 4" 7"

    5"

    3' - 0"

    3' -

    0"

    5 1

    /4"

    1' -

    1 1

    /4"

    1' -

    5 1

    /2"

    9 1

    /2"

    1 1

    /2"

    1 1/2"

    GRADE BEAM

    FOUNDATION WALLON STRIP FOOTING

    OUTSIDE FACE OF GRADE WALL

    1 1/2"X1 1/2" NOTCH FORWALL PANEL

    PEMB BASE PLATE

    4) 3/4" F1554 GR36 ANCHOR RODS WITH 12" EMBEDMENT AND 3" PROJECTION. PROVIDE NUT & LARGE HD WASHER TACK WELDED BOTTOM

    4)#6 VERTICAL

    4)#4 TIES WITH 2 AT TOP

    OUTSIDE FACE OF GRADE BEAM1

    C

    7" 1' - 4" 7"

    2' - 6"5" 1"

    1' - 0"

    3' -

    0"

    FOUNDATION WALLON STRIP FOOTING

    OUTSIDE FACE OF GRADE WALL

    1 1/2"X1 1/2" NOTCH FORWALL PANEL

    PEMB BASE PLATE

    4) 3/4" F1554 GR36 ANCHOR RODS WITH 12" EMBEDMENT AND 3" PROJECTION. PROVIDE NUT & LARGE HD WASHER TACK WELDED BOTTOM

    4)#6 VERTICAL

    4)#4 TIES WITH 2 AT TOP

    #5 HAIRPIN BAR

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    S-101

    PEMB BASE

    PLATES &PIER DETAILS

    2019-1576

    MSC

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    STRUCTURAL

    No.

    Descriptio

    nD

    ate

    SCALE: 1 1/2" = 1'-0"

    1 PEMB BASE PLATE A NEW

    SCALE: 1 1/2" = 1'-0"

    2 PEMB BASE PLATE B NEW

    SCALE: 1 1/2" = 1'-0"

    3 PEMB BASE PLATE C NEW

    SCALE: 1 1/2" = 1'-0"

    4 PEMB BASE PLATE D NEW

    SCALE: 1 1/2" = 1'-0"

    5 PEMB BASE PLATE E NEW

    SCALE: 1 1/2" = 1'-0"

    6 PEMB BASE PLATE F NEWSCALE: 1 1/2" = 1'-0"

    7 PEMB BASE PLATE G NEW

    S-100 SCALE: 1" = 1'-0"

    9 TYPICAL PIER AT PEMB BASE PLATE D

    S-100 SCALE: 1" = 1'-0"8 TYPICAL PIER AT PEMB BASE PLATE E

    S-100 SCALE: 1" = 1'-0"

    10 TYPICAL PIER AT PEMB BASE PLATE B - LINE 5

    S-100 SCALE: 1" = 1'-0"11 TYPICAL PIER AT PEMB BASE PLATE C - LINE 5

    S-100 SCALE: 1" = 1'-0"12 TYPICAL PIER AT PEMB BASE PLATE A - LINE 1

    S-100 SCALE: 1" = 1'-0"13 TYPICAL PIER AT PEMB BASE PLATES B & C - LINE 1

  • 1 2

    A

    B

    C

    D

    6

    S-301

    FUTURE OFFICE SPACE

    30

    4

    S-301

    R @ 6 15/16"19

    1

    S-301

    S-1052

    S-1052

    5

    A-305

    WIT

    H 3

    / 4"

    T&

    G F

    IRE

    TR

    EA

    TE

    D P

    LY

    WO

    OD

    SU

    B-F

    LO

    OR

    12

    " 14

    GA

    LIG

    HT

    GA

    GE

    JO

    IST

    S @

    16

    " O

    .C. -

    PR

    OV

    IDE

    16

    GA

    CR

    IPP

    LE

    ST

    UD

    S A

    T E

    AC

    H E

    ND

    WITH 3/4" T&G FIRE TREATED PLYWOOD SUB-FLOOR

    6" 16GA LIGHT GAGE JOISTS @ 16" O.C.

    HSS12X3X3/16(EL: 111' - 4")

    HSS12X3X3/16(EL: 111' - 4")

    C12X

    20.7

    ST

    RIN

    GE

    R

    C12X

    20.7

    ST

    RIN

    GE

    R

    CONCRETE FILLED PAN STAIR TREAD WITH RISER

    1 1

    /4"

    4 1/2"

    9 1

    /2"

    1"

    3/16"

    1"

    1 1

    /4"

    3/8" BASE PLATE

    1/2" TAPCON OR EQUALSCREW-IN ANCHORS W/3" EMBEDMENT

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35

    Pu

    bli

    c S

    qu

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    427

    01

    Off

    ice:

    (27

    0)

    73

    7-4

    22

    6 •

    Fa

    x:

    (270

    ) 73

    7-0

    44

    1

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    S-105

    2ND FLOOR

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    STRUCTURAL

    No.

    Description

    Date

    A-305 SCALE: 1/4" = 1'-0"

    1 MEZZANINE - STRUCTURAL

    S-105 SCALE: 1 1/2" = 1'-0"

    2 LANDING SUPPORT BASE PLATE

  • T/SLAB100' - 0"

    D

    9 1/2"

    RIGID INSULATION

    4" CLEAN CRUSHED#57 STONE

    2' -

    6"

    8)#5x24" DOWELS

    EXTERIOR PAVEMENT

    3)#5 CONTINUOUS(TOP BAR DROPED)

    #4@18" O.C.

    5" SLAB

    WWF

    SLOPE 1/2" AT OVERHEAD DOOR ISOLATION JOINT

    T/SLAB100' - 0"

    9 1/2"

    5" SLAB(SEE PLAN)

    2" RIGID INSULATION

    4" CLEAN #57CRUSHED STONE

    3) #5 CONT. WITH#4 HOOK TIES AT 18" O.C.

    4"

    GRADE 5% SLOPEMINIMUM

    1 1/2"1 1/2"

    T/SLAB100' - 0"

    5

    8' - 3 7/8"

    METAL GRALVANIZED/BANDEDGRATING

    1' -

    7"

    ETHANOL STORAGE #2

    14

    1' -

    6"

    6"

    6' - 0"

    HSS6X3X3/16 GALVANIZED

    EM

    BE

    DM

    EN

    T

    ALL ANCHOR RODS: F1554 GRADE 36

    3"

    1' - 0"

    CONSTRUCTION JOINT, WALL FACE, OR COLUMNCORNER

    #4 x 3'-0" TOP & BOTTOM

    #4 x 5'-0" TOP & BOTTOM

    SLAB ON GRADE

    T/SLAB100' - 0"

    1

    5" SLAB(SEE PLAN)

    2" RIGID INSULATION

    4" CLEAN #57CRUSHED STONE

    6) #4 CONT.

    GRADE 5% SLOPEMINIMUM

    4"

    2' -

    6"

    1' -

    0"

    2' - 6"

    1 1

    /2"

    #4 @ 18" O.C.

    3) #5 CONT. WITH #5 CROSS BARS AT 12" O.C.

    7" 1' - 4" 7"

    6" 16GA LOAD BEARING STUDS

    ANCHOR 6" TRACK WITH1/2" "TAPCON" TYPE SCREWSAT 4'-0" O.C., TYP. AT LOAD BEARING WALLS

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    S-300

    SECTIONS

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    STRUCTURAL

    S-100 SCALE: 3/4" = 1'-0"1 POUR-THROUGH @ OVERHEAD DOOR

    S-100 SCALE: 3/4" = 1'-0"2 GRADE BEAM SECTION, TYP. LINE A, D & 5

    No.

    Descriptio

    nD

    ate

    S-100 SCALE: 3/4" = 1'-0"3 PIT SECTION

    SCALE: 1 1/2" = 1'-0"

    5 TYPICAL ANCHOR ROD EMBEDMENTSCALE: 1/2" = 1'-0"

    6 TYPICAL RE-ENTRY REINFORCINGS-100 SCALE: 3/4" = 1'-0"

    4 FOUNDATION WALL AT COLUMN LINE 1

  • T/SLAB100' - 0"

    T/STEEL118' - 0"

    1

    2ND FLOOR111' - 0"

    S-3012

    S-3013

    15' - 0 1/8"

    1' -

    0"

    2' - 0"

    12" x 24" THICKENED SLAB@ BEARING WALL,WITH

    3) #5 CONTINUOUS, AND #5 @ 18" O.C.

    15' - 6 1/4"

    2ND FLOOR111' - 0"

    12" 14 GA TRACK

    3/4" FIRE TREATEDT&G PLYWOOD

    SUBFLOOR

    12" 14GA FLOOR JOIST @ 16" O.C.

    HSS6X3X3/16

    6" TOP TRACK

    6" 16GA METALSTUDS @ 16" O.C.

    6" TRACK

    6" 16GA METALSTUDS @ 16" O.C.

    12" LONG 6" 16GA STUDSQUASH BLOCK @ EACH JOIST END, TYP

    1

    2ND FLOOR111' - 0"

    3/4" FIRE TREATEDT&G PLYWOODSUBFLOOR

    12" 14GA FLOOR JOIST @ 16" O.C.

    HSS6X3X3/16

    6" TOP TRACK

    METAL BUILDING INSULATION

    12" 14 GA TRACK

    6" 16GA METALSTUDS @ 16" O.C.

    6" TRACK

    6" 16GA METALSTUDS @ 16" O.C.

    12" LONG 6" 16GA STUDSQUASH BLOCK @ EACH

    JOIST END, TYP

    T/SLAB100' - 0"

    T/STEEL118' - 0"

    C

    2ND FLOOR111' - 0"

    6

    S-301

    5' - 6"

    HSS12X3X3/16

    3/4" FIRE-TREATEDT&G PLYWOOD

    S-3015

    2ND FLOOR111' - 0"

    14GA BENT PLATE

    6" 14GA METAL JOISTS @ 16" O.C.

    HSS12X3X3/16

    3/4

    "

    3/4" FIRE-TREATEDT&G PLYWOOD SUB

    FLOOR

    1 1/2" SCHED 40 RAILING

    RA

    ILIN

    G H

    EIG

    HT

    3' -

    6"

    T/SLAB100' - 0"

    T/STEEL118' - 0"

    2

    2ND FLOOR111' - 0"

    4

    S-301

    NOTCH

    3' - 0"

    1' - 1 1/8"

    10

    ' - 4

    "

    S-3017

    1 1/2" SCHED 40RAILING

    6" 16GA METAL STUD WALLWITH 5/8 FIRE RATED GYPBOARD & 6" INSULATION

    S-3018

    CONCRETE FILLED PAN STAIR

    INSULATION NOT SHOWN FOR CLARITY

    6" 18GA METAL STUD WALLWITH 5/8 GYP BOARD

    & 6" INSULATION

    HSS3-1/2X3-1/2X1/4

    2

    2ND FLOOR111' - 0"

    4 3

    /4"

    6" 14GA JOISTS @ 16" O.C.

    NOTCH

    3' - 0"3/4" FIRE TREATED T&GPLYWOOD SUB FLOOR

    HSS12X3X3/16

    HSS3-1/2X3-1/2X1/4W/ 3/8" CAP

    BOTH SIDES

    3/8

    "

    5" 3X3X1/8 BENT PLATE CLIPSWELDED TO TUBE @ 16" O.C.

    5"

    INSULATION NOT SHOWN FOR CLARITY

    SUPPLY 1/4" CLOSURE PLATE, GRIND SMOOTH

    CONCRETE FILLEDPAN STAIR BEYOND

    2ND FLOOR111' - 0"

    4"

    5" 3X3X1/8 BENT PLATE CLIPSWELDED TO TUBE @ 16" O.C.

    4 3

    /4"

    HSS6X2X3/16

    HSS12X3X3/16

    6" 14GA JOISTS@ 16" O.C.

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    S-301

    STAIR &

    LANDINGSECTIONS

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    STRUCTURAL

    No.

    Descriptio

    nD

    ate

    A-100 SCALE: 1/4" = 1'-0"

    1 OFFICE, CONFERENCE/BREAK ROOM SECTIONS-301 SCALE: 1" = 1'-0"

    2 DETAIL @ INTERNAL BEARING WALL

    S-301 SCALE: 1" = 1'-0"

    3 DETAIL @ EXTERNEL BEARING WALLA-105 SCALE: 1/4" = 1'-0"4 LANDING SECTION

    S-301 SCALE: 1" = 1'-0"

    5 LANDING SECTION DETAIL

    A-105 SCALE: 1/4" = 1'-0"

    6 Section 13

    S-301 SCALE: 1" = 1'-0"

    7 LANDING @ STAIR WALLS-301 SCALE: 1" = 1'-0"

    8 LANDING @ BEARING WALL

  • UP

    1 2 3 4 5

    A

    B

    C

    D

    25' - 0" 25' - 0" 25' - 0" 25' - 0"

    20

    ' - 0

    "2

    0' -

    0"

    20

    ' - 0

    "

    100' - 0"

    6' - 0"14' - 5 5/8"

    29

    ' - 0

    1/4

    "

    15' - 0"

    15

    ' - 0

    "

    13

    ' - 3

    3/8

    "

    12

    ' - 0

    "1

    7' -

    9 3

    /4"

    10'-0"X12'-0" OH DOOR

    36"X60"

    36"X

    60"

    36"X

    60"

    36"X

    60"

    36"X

    60"

    36"X

    60"

    6' - 0"

    36"X60"

    36"X

    60"

    GRAY & RED WALLS TO DECK & INSULATED(ETHANOL STORAGE WALLS DO NOT GO TO DECK)

    23

    ' - 3

    1/4

    "

    9' - 6 3/4"

    1

    A-305

    4' -

    0 1

    /2"

    ENTRANCE VESTIBULE

    1

    OFFICE

    2

    CONFERENCE

    3

    BREAK ROOM

    4

    CORRIDOR

    5

    WOMEN'S ROOM

    6

    MEN'S ROOM

    7

    UTILITY

    8

    FUTURE LAB

    9

    1653 SF

    PROCESSING ROOM

    10

    PROCESS UTILITY

    11

    BULK HEMP STORAGE

    12

    ETHANOL STORAGE #2

    14

    SHIPPING/RECEIVING

    15

    5' -

    6"

    5' -

    6"

    4' -

    9"

    5' -

    6"

    CLOSET

    16

    3

    2 18

    17

    15

    14

    13

    16

    1

    4

    5

    7

    6

    8 9

    22

    21

    1919

    4' -

    0"

    1' -

    3 7

    /8"

    A-405

    1

    A-405 2A-405

    3

    A-4054

    A-4055

    MAPES CANOPY LUMISHADEOR EQUAL

    10' - 0"

    10

    ' - 0

    "

    12

    SINKWATER HEATER

    MOP SINK

    SINK

    6' -

    2 3

    /8"

    7 1

    /4"

    6' -

    6 3

    /8"

    10' - 0"

    10

    ' - 0

    "

    6' -

    0"

    6' - 0"

    MAPES CANOPY LUMISHADEOR EQUAL

    ETHANOL STORAGE #1

    13

    29' - 8 3/8" 29' - 3 3/8"

    10

    ' - 0

    "

    18' - 7 7/8" 10' - 7 1/2"

    27' - 4 3/8"

    44

    ' - 0

    7/8

    "

    43' - 8 5/8"

    9' - 6"

    6' - 0"

    2

    A-305

    7' - 0"

    1

    S-301

    5

    A-305

    11

    4

    A-305

    1

    A-305

    6

    A-305

    FIRE RATED WALLSTO 9'-1 1/4" ONLY

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    A-100

    FLOOR PLAN

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    ARCHITECTURAL

    A-300 SCALE: 1/4" = 1'-0"

    1 FLOOR PLAN

    No.

    Descriptio

    nD

    ate

  • 1 2

    A

    B

    C

    D

    6

    S-301

    FUTURE OFFICE SPACE

    30

    3/4" FIRE-TREATED T&GPLYWOOD ON 12" 14GALIGHT GAGE METAL JOISTS

    LANDING @ 11'-0" AFF

    R @ 6 15/16"1914' - 5 5/8"

    58

    ' - 0

    3/4

    "

    4

    S-301

    1

    S-301

    5

    A-305

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    A-105

    2ND FLOOR

    PLAN

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    ARCHITECTURAL

    No.

    Descriptio

    nD

    ate

    A-305 SCALE: 1/4" = 1'-0"

    1 2ND FLOOR

  • 1 2 3 4 5

    A

    B

    C

    D

    1

    A-305

    FUTURE LAB

    9

    BULK HEMP STORAGE

    12

    PROCESSING ROOM

    10

    BREAK ROOM

    4

    CORRIDOR

    5

    CONFERENCE

    3

    OFFICE

    2

    PROCESS UTILITY

    11

    SHIPPING/RECEIVING

    15

    ETHANOL STORAGE #2

    14

    ENTRANCE VESTIBULE

    1

    CLOSET

    16

    MEN'S ROOM

    7

    WOMEN'S ROOM

    6

    UTILITY

    8

    NO CEILING

    A-405

    1

    A-405 2A-405

    3

    A-4054

    6

    S-301

    NO CEILING

    NO CEILING

    NO CEILING

    2

    A-305

    4

    S-301

    1

    S-301

    GYP BOARD CEILING @ 9'-0" A.F.F.(2 LAYERS 5/8" FIRERATED GYP BOARD)

    GYP BOARD CEILING @ 9'-0" A.F.F.(2 LAYERS 5/8" FIRE RATED GYP BOARD)

    NO CEILING

    NO CEILING

    GYP BOARDCEILINGS @8'-0" A.F.F.

    2' X 2' ACT@ 8'-6" A.F.F.

    2' X 2' ACT@ 8'-6" A.F.F.

    5

    A-305

    GYP BOARD CEILING@ 8'-0" A.F.F.

    4

    A-305

    ETHANOL STORAGE #1

    13

    6

    A-305

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    A-110

    REFLECTED

    CEILING PLAN

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    ARCHITECTURAL

    No.

    Descriptio

    nD

    ate

    A-300 SCALE: 1/4" = 1'-0"

    1 REFLECTED CEILING PLAN

  • T/SLAB100' - 0"

    T/STEEL118' - 0"

    A B C D123' - 0 11/16"

    5' - 6" 5' - 6" 4' - 9" 5' - 6"

    6

    S-301

    MAPES CANOPY LUMISHADE OR EQUAL

    30' - 5 7/8"

    T/SLAB100' - 0"

    T/STEEL118' - 0"

    1

    2345

    6' - 0 1/2"

    T/SLAB100' - 0"

    1

    2 3 4 5

    6' - 0 1/2"5

    ' - 5

    3/4

    "5

    ' - 0

    "5

    ' - 1

    "7

    ' - 5

    "

    22

    ' - 1

    1 3

    /4"

    4' -

    8"

    7' -

    4"

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    A-300

    ELEVATIONS

    & 3D VIEW

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    ARCHITECTURAL

    SCALE: 1/8" = 1'-0"

    1 WEST

    SCALE: 1/8" = 1'-0"

    2 NORTH

    SCALE: 1/8" = 1'-0"

    3 SOUTH

    SCALE:

    4 3-D VIEW

    No.

    Descriptio

    nD

    ate

    MAPES CANOPY LUMISHADEOR EQUAL

  • T/SLAB100' - 0"

    D

    3 5/8" METAL STUDS @ 16" O.C.

    2) LAYERS OF 5/8" FIRE RATED GYP BOARD

    8" GIRT, BY METALBUILDING MFGR.

    METAL BLDGEXTERIOR PANEL

    FOUNDATION WALLSEE STRUCTURAL

    BUILDING INSULATION

    PROVIDE 1/2" GAP TO DECK. FILL GAP WITH FIRE-RATED FOAM

    RESINOUS EPOXY BASE

    SEALED CONCRETE

    T/SLAB100' - 0"

    T/STEEL118' - 0"

    5/8" FIRE RATED GYP BOARD

    5/8" FIRE RATED GYP BOARD

    BUILDING INSULATION

    6" 16GA METAL STUDS@ 16" O.C.

    A-3053

    SIM

    PARTITIONS PARALLEL TO DECK FLUTES

    1HR FIRE-RATINGSCONSTRUCT PER UL DESIGN HW-D-0587

    PARTITIONS PERPENDICULAR TO DECK FLUTES

    1HR FIRE-RATINGSCONSTRUCT PER UL DESIGN HW-D-0577

    CONTINUOUS STEEL STRAP

    DEFLECTION TRACK

    PACKING MATERIALS IN VOID BEYOND

    FIRE-RATED JOINT ASSEMBLY CONSISTING OF SLOTTED TRACK WITH OVERLAPPING GYPSUM BOARD (NUMBER OF GYP. BOARD LAYERS VARIES PER DESIGN)

    FIRE SAFINGINSULATION

    1" 1"

    FIRE SAFINGINSULATION

    FIRE SAFING INSULATION

    T/SLAB100' - 0"

    T/STEEL118' - 0"

    5/8" FIRE RATED GYP BOARD

    6" INSULATION

    5/8" FIRE RATED GYP BOARD

    6" 18GA METAL STUDS@ 16" O.C.

    BUILDINGINSULATION A-305

    3SIM

    T/SLAB100' - 0"

    2

    2ND FLOOR111' - 0"

    7" / 1

    2"

    3' - 6"

    A-3053

    SIM

    5/8" GYP BOARDBOTH SIDES

    6" 18GA METALSTUDS @ 16"

    O.C.

    FIRE RATED DOOR

    5/8" FIRE RATED GYP BOARD BOTHSIDES

    9/16" METAL DECK ON 8" 20GA JOISTS @ 16" O.C.

    6' TRACK

    8' -

    0"

    T/SLAB100' - 0"

    C

    9' AFF109' - 0"

    2) LAYERS 5/8" FIRE RATED GYP BOARD CEILING

    9/16" METAL DECKINGON 8" 20GA JOISTS @16" O.C.

    1X6 POPLAR TRIM

    5/8" FIRE RATED GYP BOARD BOTH SIDES

    6" 18GA METAL STUDS@ 16" O.C.

    6" INSULATION

    6" TOP TRACK

    6" TRACK

    8" TRACK

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    A-305

    WALL

    SECTIONS

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    ARCHITECTURAL

    No.

    Descriptio

    nD

    ate

    A-100 SCALE: 3/4" = 1'-0"1 FIRE RATED EXTERIOR WALL SECTION

    A-100 SCALE: 3/4" = 1'-0"2 PROCESSING ROOM WALL SECTION

    A-305 SCALE: 3" = 1'-0"

    3 INTERSECTION OF FIRE-RATED PARTITION WITH METAL DECK ABOVE

    A-100 SCALE: 3/4" = 1'-0"4 FIRE RATED WALL SECTION

    A-100 SCALE: 3/4" = 1'-0"5 CLOSET SECTION

    A-100 SCALE: 3/4" = 1'-0"

    6 ETHANOL STORAGE WALL SECTION

    DETAILS TO BE DETERMINEDNEED TO DISCUSS PEMB INSULATION INSTALL

  • 3'-3"

    5'-0" MIN. CLEAR

    8" 1'-6"

    2'-0"

    3'-0"

    1'-0" 3'-6" 3'-0" 6"

    17"-

    19"

    1'-2"

    4'-0" 5'-6"

    2'-10"

    1'-3"

    MIN

    .

    4'-0"

    MA

    X.

    3'-4"

    3'-8"

    HIG

    H C

    ON

    TR

    OL

    3'-4"

    3'-0"

    MA

    X. S

    PO

    UT

    3'-2"

    MIN

    . S

    PO

    UT

    3'-7"

    MA

    X. S

    PO

    UT

    3'-8"

    HA

    ND

    LE

    3'-8"

    DO

    OR

    PU

    LL

    3'-4"

    3'-0"

    5'-0"

    2'-9-1

    /2"

    1'-6"

    3'-3"

    AD

    A W

    AT

    ER

    CLO

    SE

    T

    TO

    ILE

    T P

    AP

    ER

    DIS

    PE

    NS

    ER

    GR

    AB

    BA

    RS

    RE

    ST

    RO

    OM

    ST

    ALL

    SA

    NIT

    AR

    Y N

    AP

    KIN

    VE

    ND

    OR

    MIR

    RO

    R, C

    EN

    TE

    RE

    D O

    N L

    AV

    AT

    OR

    YA

    DA

    LA

    VA

    TO

    RY

    CO

    NT

    RO

    LS

    FO

    R A

    LL IT

    EM

    ST

    O B

    E L

    OC

    AT

    ED

    WIT

    HIN

    TH

    ISA

    RE

    A U

    NLE

    SS

    NO

    TE

    D O

    TH

    ER

    WIS

    E

    ELE

    CT

    RIC

    HA

    ND

    DR

    YE

    R

    AD

    A W

    AT

    ER

    CLO

    SE

    T

    GR

    AB

    BA

    RS

    RE

    ST

    RO

    OM

    ST

    ALL

    AD

    A C

    OA

    T H

    OO

    K/R

    OD

    CO

    AT

    HO

    OK

    /RO

    DT

    YP

    ICA

    L H

    EIG

    HT

    PR

    OV

    IDE

    (1)

    AT

    EA

    CH

    LO

    CA

    TIO

    N

    AD

    A T

    RA

    P W

    RA

    PH

    W, C

    W, A

    ND

    DR

    AIN

    LIN

    ES

    NOTE:

    ALL INSTALLATIONS SHALL COMPLY WITH ALL CURRENT GOVERNING CODES

    AND REQUIREMENTS FOR ACCESSIBILITY AND MOUNTING HEIGHTS,

    INCLUDING IBC, ADA, ANSI A117.1, ETC.

    AD

    A E

    LE

    CT

    RIC

    WA

    TE

    R C

    OO

    LE

    R

    ELE

    CT

    RIC

    WA

    TE

    R C

    OO

    LE

    RO

    R W

    AT

    ER

    FO

    UN

    TA

    IN

    OR

    WA

    TE

    R F

    OU

    NT

    AIN

    FIR

    E E

    XT

    ING

    UIS

    HE

    R W

    / B

    RA

    CK

    ET

    FIR

    E E

    XT

    ING

    UIS

    HE

    R W

    / C

    AB

    INE

    T

    PA

    PE

    R T

    OW

    EL D

    ISP

    EN

    SE

    R

    MO

    P H

    AN

    GE

    R

    DIA

    PE

    R C

    HA

    NG

    ING

    ST

    AT

    ION

    SA

    NIT

    AR

    Y N

    AP

    KIN

    DIS

    PO

    SA

    L

    TO

    ILE

    T P

    AP

    ER

    DIS

    PE

    NS

    ER

    SA

    NIT

    AR

    Y N

    AP

    KIN

    DIS

    PO

    SA

    L

    ST

    AN

    DIN

    G/T

    ALLE

    R H

    EIG

    HT

    TY

    PIC

    AL/L

    OW

    ER

    HE

    IGH

    T

    TO

    TO

    P O

    F H

    OR

    IZ. S

    UR

    FA

    CE

    T/SLAB100' - 0"

    2

    ADA GRABBARS

    TOILET TISSUEDISPENSER

    TOILET

    GYP BDCEILING

    8' AFF108' - 0"

    T/SLAB100' - 0"

    ADA GRAB BARS

    TOILET TISSUE DISPENSER

    SANITARY NAPKINDISPOSAL (WOMEN'SROOM ONLY)

    TOILET

    GYP BDCEILING

    8' AFF108' - 0"

    T/SLAB100' - 0"

    2

    GYP BDCEILING

    8' AFF108' - 0"

    MIRROR

    WALL MOUNT SINK

    PAPER TOWELDISPENSER

    TRASH CAN

    T/SLAB100' - 0"

    MIRROR

    WALL MOUNT SINK

    GYP BDCEILING

    8' AFF108' - 0"

    PAPER TOWEL DISPENSER

    2

    A-405

    1

    A-405 2A-405

    3

    A-4054

    MEN'S ROOM

    7

    WOMEN'S ROOM

    6

    SUPPLY SHELVING

    ADA GRAB BARS

    WALL MOUNT SINK

    TOILET TISSUEDISPENSER

    TOILET

    ADA GRAB BARS

    WALL MOUNT SINK TOILET TISSUE

    DISPENSER

    TOILET

    PAPER TOWEL DISPENSER

    PAPER TOWEL DISPENSER

    TRASH CAN

    TRASH CAN

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    A-405

    RESTROOM

    SECTIONS,PLAN &

    ACCESSORYHEIGHTS

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    ARCHITECTURAL

    No.

    Descriptio

    nD

    ate

    SCALE: 1/4" = 1'-0"

    6 TYPICAL RESTROOM ACCESSORY HEIGHTS

    A-100 SCALE: 1/2" = 1'-0"

    1 RESTROOM ELEVATION 1A-100 SCALE: 1/2" = 1'-0"

    2 RESTROOM ELEVATION 2A-100 SCALE: 1/2" = 1'-0"

    3 RESTROOM ELEVATION 3A-100 SCALE: 1/2" = 1'-0"

    4 RESTROOM ELEVATION 4

    NOTE: ELEVATIONS SHOWN ARE AT WOMEN'S RESTROOM. MEN'S ROOM ACCESSORY PLACEMENT IS MIRRORED

    A-100 SCALE: 1/2" = 1'-0"5 ENLARGED RESTROOM PLAN

  • JACK STUDS

    HEADER, SIZE & GAUGE AS REQUIRED

    STIFFENING PLATE

    TYPICAL METAL STUD WALL FRAMING

    CRIPPLE STUDS

    CLIP

    BOTTOM TRACK, SIZE AND GAGE AS REQUIRED

    1/2" TAPCON ANCHORS @ 24" MAX OR WITHIN 6" EACH SIDE OF A JOINT, WITH 3" EMBEDMENT ON EXTERIOR WALLS OR INTERIOR LOAD BEARING WALLS ONLY. PROVIDE POWDER ACTUATED FASTENERS @ INTERIOR NON-LOAD BEARING WALLS.

    JACK STUDS

    HEADER, SIZE & GAUGE AS REQUIRED

    STIFFENING PLATE

    TYPICAL METAL STUD WALL FRAMING

    CRIPPLE STUDS

    BOTTOM TRACK, SIZE AND GAGE AS REQUIRED

    JACK STUDS

    CLIP CLIP

    CLIP CLIP

    1/2" TAPCON ANCHORS @ 24" MAX OR WITHIN 6" EACH SIDE OF A JOINT, WITH 3" EMBEDMENT.

    HM FRAME

    MIN. (3) PER JAMBJAMB ANCHORS

    @ JAMB

    5/8" GYP. BOARD

    DOUBLE 20 GA. STUDS

    SEALANT (BOTH SIDES)

    MTL. STUDS @ 16" O.C.

    (SEE PLAN FOR SIZE)

    DOOR

    2"

    B

    HM FRAME

    SEALANT (BOTH SIDES)

    5/8" GYP. BOARD

    MTL. STUDS @ 16" O.C.

    (SEE PLAN FOR SIZE)

    DOOR

    A

    4' -

    0"

    3' - 0"

    3' -

    0"

    7' -

    0"

    3' - 0"

    7' -

    0"

    3' - 0"

    8"6"

    2' -

    9"

    8"

    1 2

    7' -

    0"

    6' - 0"

    3

    DOOR GLASS TYPES

    1/4" LAMINATED SAFETY CLASS; CLEAR

    2"DOORWIDTH 2"

    7' -

    0"

    7' -

    2"

    2"

    A B

    2" DOOR WIDTH 2"

    7' -

    0"

    2"

    HOLLOWMETAL

    HOLLOWMETAL

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    A-505

    DOOR/

    WINDOWDETAILS &

    SCHEDULES

    2019-1576

    Author

    Checker

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    ARCHITECTURAL

    No.

    Descriptio

    nD

    ate

    SCALE: 1/2" = 1'-0"

    1 TYPICAL METAL STUD DOOR HEADER DETAILSCALE: 1/2" = 1'-0"

    2 TYPICAL METAL STUD WINDOW HEADER DETAILSCALE: 1 1/2" = 1'-0"

    3 DOOR DETAIL H. M. JAMBSCALE: 1 1/2" = 1'-0"

    4 DOOR DETAIL H.M. HEAD

    SCALE: 1/4" = 1'-0"

    5 WINDOW ELEVATIONSCALE: 1/4" = 1'-0"

    6 DOOR ELEVATIONS

    DOOR SCHEDULE

    MARK MATERIALDOOR

    ELEVATION FRAMEFRAME

    ELEVATION HEIGHT WIDTH FUNCTIONFIRE

    RATED COMMENTS

    1 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0"

    2 HOLLOW METAL 3 HOLLOW METAL A 7' - 0" 3' - 0" W/ VISION PANE

    3 HOLLOW METAL 3 HOLLOW METAL A 7' - 0" 3' - 0" W/ VISION PANE

    4 HOLLOW METAL 3 HOLLOW METAL A 7' - 0" 3' - 0" W/ VISION PANE

    5 HOLLOW METAL 3 HOLLOW METAL A 7' - 0" 3' - 0" W/ VISION PANE

    6 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0"

    7 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0"

    8 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0" 1 HR

    9 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0" 1 HR

    11 HOLLOW METAL 2 HOLLOW METAL B 7' - 0" 6' - 0" 1 HR

    12 HOLLOW METAL 2 HOLLOW METAL B 7' - 0" 6' - 0" 1 HR

    13 HOLLOW METAL 2 HOLLOW METAL B 7' - 0" 6' - 0"

    14 HOLLOW METAL 2 HOLLOW METAL B 7' - 0" 6' - 0" 1 HR

    15 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0"

    16 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0"

    17 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0" 1 HR

    18 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0" 1 HR

    19 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0" 1 HR

    20 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0"

    21 HOLLOW METAL 1 HOLLOW METAL A 7' - 0" 3' - 0"

    22 12' - 0" 10' - 0" OVERHEAD DOOR

    SCALE: 1/4" = 1'-0"

    7 FRAME ELEVATIONS

    ROOM FINISH SCHEDULE

    ROOMNO. ROOM NAME WALL FINISH CEILING FINISH

    CEILINGHEIGHT BASE FINISH FLOOR FINISH

    1 ENTRANCE VESTIBULE PAINTED GYP BOARD 24" X 24" ACT 8'-6" 4" VINYL SEALED CONCRETE

    2 OFFICE PAINTED GYP BOARD 24" X 24" ACT 8'-6" 4" VINYL SEALED CONCRETE

    3 CONFERENCE PAINTED GYP BOARD 24" X 24" ACT 8'-6" 4" VINYL SEALED CONCRETE

    4 BREAK ROOM PAINTED GYP BOARD 24" X 24" ACT 8'-6" 4" VINYL SEALED CONCRETE

    5 CORRIDOR PAINTED GYP BOARD NONE N/A 4" VINYL SEALED CONCRETE

    6 WOMEN'S ROOM PAINTED GYP BOARD GYPSUM BOARDCEILING

    8'-0" 4" VINYL SEALED CONCRETE

    7 MEN'S ROOM PAINTED GYP BOARD GYPSUM BOARDCEILING

    8'-0" 4" VINYL SEALED CONCRETE

    8 UTILITY PAINTED GYP BOARD NONE NONE 4" VINYL SEALED CONCRETE

    9 FUTURE LAB FIRE RATED GYP BOARD 2LAYERS ON EXTERIOR WALL

    NONE 10'-0" NONE SEALED CONCRETE

    10 PROCESSING ROOM PAINTED GYP BOARD & 8'-0"FRP

    NONE 10'-0" NONE SEALED CONCRETE

    11 PROCESS UTILITY PAINTED GYP BOARD NONE 10'-0" 4" VINYL SEALED CONCRETE

    12 BULK HEMP STORAGE PEMB METAL LINER PANEL -APPROX. 8'-0"

    NONE 10'-0" 4" VINYL SEALED CONCRETE

    13 ETHANOL STORAGE #1 FIRE RATED GYP BOARD FIRE RATED GYPBOARD 2) LAYERSOF 5/8"

    8'-0" 4" VINYL SEALED CONCRETE WITH GALAV, STEEL GRATING

    14 ETHANOL STORAGE #2 FIRE RATED GYP BOARD FIRE RATED GYPBOARD 2) LAYERSOF 5/8"

    8'-0" 4" VINYL SEALED CONCRETE WITH GALAV, STEEL GRATING

    15 SHIPPING/RECEIVING PEMB METAL LINER PANEL -APPROX. 8'-0"

    NONE NONE 4" VINYL SEALED CONCRETE

    16 CLOSET PAINTED GYP BOARD GYPSUM BOARDCEILING

    8'-0" 4" VINYL SEALED CONCRETE

  • PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    A-900

    3-D VIEW

    2019-1576

    LEA

    MSC

    8/23/2019

    95%

    RE

    VIE

    W D

    OC

    S

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    ARCHITECTURAL

    No.

    Descriptio

    nD

    ate

    SCALE:

    1 3D VIEW

  • SHEET METAL DUCTWORK

    1. AIR DISTRIBUTION DUCTWORK, INCLUDING SUPPLY, RETURN, AND EXHAUST DUCTWORK SHALL BE FABRICATED FROM PRIME QUALITY GALVANIZED SHEET METAL IN ACCORDANCE WITH THE 2006 INTERNATIONAL MECHANICAL CODE AND SMACNA HVAC DUCT CONSTRUCTION MANUAL.

    2. AIR DISTRIBUTION DUCTWORK SHALL BE DELIVERED TO THE SITE IN UNDAMAGED AND CLEAN CONDITION. DUCTWORK SHALL BE PROTECTED DURING STORAGE AND INSTALLATION AGAINST DAMAGE AND CONTAMINATION.

    3. DUCTWORK SHALL BE SUPPORTED FROM SUITABLE BUILDING STRUCTURAL COMPONENTS. THE HVAC CONTRACTOR SHALL FURNISH ANY SUPPLEMENTARY STRUCTURAL MEMBERS REQUIRED TO PROPERLY SUPPORT THE DUCTWORK.

    4. BRANCH DUCT CONNECTIONS MAY BE MADE WITH FITTINGS OR TAPS. A BALANCING DAMPER SHALL BE INSTALLED AT EACH BRANCH DUCT CONNECTION. PROVIDE RAKE-OFFS OR SCOOPS AT EACH BRANCH CONNECTION.

    5. DIFFUSER RUNOUT CONNECTIONS SHALL BE MADE WITH SPIN-IN OR DOVETAIL TAPS. A BALANCING DAMPER SHALL BE INSTALLED FOR EACH RUNOUT.

    6. THE HVAC CONTRACTOR MAY SUBSTITUTE EQUIVALENT ROUND DUCT FOR THE RECTANGULAR DUCT SHOWN ON THE DRAWINGS.

    7. PROVIDE AIR TURNING VANES IN MITERED FITTINGS. PROVIDE SPLITTER DAMPERS IN RADIUS WYES OR TEES.

    8. DIFFUSER CONNECTIONS MAY BE MADE WITH METAL ELBOWS OR FLEX DUCT. FLEX DUCT RUNS SHALL NOT EXCEED 6’-0” IN LENGTH.

    9. ALL BALANCING DAMPERS SHALL BE ACCESSIBLE. PROVIDE ACCESS PANELS FOR DAMPERS LOCATED ABOVE HARD CEILINGS. MARK THE LOCATION OF DAMPERS LOCATED ABOVE LAY-IN CEILINGS.

    10. ALL DUCTWORK SHALL BE SEALED AIR-TIGHT WITH MASTIC NON-HARDENING DUCT SEALANT.

    CONDENSING FURNACE & HEATER VENTING & COMBUSTION AIR INTAKE

    1. FURNISH AND INSTALL COMBUSTION AIR INTAKE AND EXHAUST VENT PIPING FOR CONDENSING FURNACE(S), USING PVC SCHEDULE 40 PIPE AND FITTINGS OR METAL VENT PIPING IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS/RECOMMENDATIONS. TERMINATE INTAKE AND EXHAUST PIPING IN ACCORDANCE WITH THE FURNACE MANUFACTURER'S RECOMMENDATIONS.

    2. PROVIDE CONDENSATE DRAIN CONNECTION AND PIPING AT BASE OF COMBUSTION EXHAUST STACK.

    REFRIGERANT TUBING

    1. INSTALL REFRIGERANT PIPING IN ACCORDANCE WITH THE HVAC EQUIPMENT MANUFACTURER'S RECOMMENDATIONS, USING ACR COPPER TUBING.

    2. FURNISH AND INSTALL REFRIGERANT SPECIALTIES IN ACCORDANCE WITH THE HVAC EQUIPMENT MANUFACTURER'S RECOMMENDATIONS.

    3. INSULATE SUCTION LINES WITH ARMAFLEX OR EQUAL INSULATION.4. INSTALL SLEEVES FOR ANY WALL PENETRATIONS. SEAL SLEEVE TO WALL.FILL SPACE

    BETWEEN SLEEVE AND TUBING WITH ELASTOMERIC SEALANT.5. SUPPORT REFRIGERANT TUBING FROM THE BUILDING STRUCTURE WITH HANGERS OR

    CLAMPS EQUAL TO HYDRA-ZORB. 6. RACK MULTIPLE PARALLEL RERIGERANT TUBING RUNS ON STRUT WITH SUITABLE

    VIBRATION ABSORBING TUBING CLAMPS.7. ROUTE REFRIGERANT TUBING RUNS EITHER VERTICAL, OR HORIZONTAL RUNS SLOPED

    PER THE EQUIPMENT MANUFACTURER'S RECOMMENDATIONS.8. REFRIGERANT TUBING JOINTS SHALL BE BRAZED USING BRAZING FILLER METAL SUCH

    AS SIL-FOS 15.9. BRAZING PROCEDURES AND PROCEDURE QUALIFICATION SHALL COMPLY WITH AWS

    STANDARDS AS OUTLINED IN AWS BRH:2007 BRAZING HANDBOOK, 5TH EDITION.

    CONDENSATE DRAINAGE

    1. PROVIDE CONDENSATE DRAIN PIPING FOR ALL HEATING AND/OR COOLING EQUIPMENT THAT PRODUCES CONDENSATION.

    2. ROUTE CONDENSATE DRAINAGE PIPING TO FLOOR DRAINS, FIXTURES, OR INDEPENDENT CONDENSATE DRAINAGE SYSTEM(S) AS SHOWN ON THE DRAWINGS.

    3. PROVIDE CONDENSATE RETURN RECEIVER & PUMP WHERE REQUIRED TO LIFT CONDENSATE TO CONDENSATE GRAVITY DRAINAGE SYSTEM.

    4. INSULATE METALLIC CONDENSATE DRAINAGE PIPING WITH FIBERGLASS OR ELASTOMERIC FOAM INSULATION.

    DUCT SMOKE DETECTORS

    1. PROVIDE SMOKE DETECTORS IN AIR HANDLING UNIT SUPPLY AND RETURN DUCTS WITH AIR HANDLING CAPACITY GREATER THAN 2000 CFM.

    2. THE SMOKE DETECTOR SHALL BE CONNECTED TO SHUT DOWN THE UNIT IN THE EVENT THAT SMOKE IS DETECTED.

    3. SMOKE DETECTORS SHALL BE COMPATIBLE WITH THE FIRE ALARM SYSTEM IF A FIRE ALARM SYSTEM IS INSTALLED. COORDINATE WITH ELECTRICAL CONTRACTOR OR INDEPENDENT FIRE ALARM CONTRACTOR.

    4. COORDINATE WIRING OF SMOKE DETECTORS WITH ELECTRICAL CONTRACTOR.

    AUTOMATIC TEMPERATURE CONTROLS/BUILDING AUTOMATION SYSTEM

    1. FURNISH AND INSTALL AUTOMATIC TEMPERATURE CONTROLS OR BUILDING AUTOMATION SYSTEM AS INDICATED ON DRAWINGS AND/OR IN SPECIFICATIONS.

    2. INSTALL LOW-VOLTAGE CONTROL WIRING IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE NFPA 70 AS ADOPTED AND ENFORCED BY THE COMMONWEALTH OF KENTUCKY.

    3. CONTROL CABLE INSTALLED IN RETURN AIR PLENUMS SHALL BE PLENUM RATED.4. CONTROL CABLE OR WIRING CONDUCTORS INSTALLED OUTSIDE THE BUILDING

    SHALL BE INSTALLED IN METALLIC RACEWAYS AND/OR SUITABLE FLEXIBLE CONDUIT AS ALLOWED BY THE NEC. UNDERGROUND CONTROL WIRING SHALL BE INSTALLED IN NON-METALLIC RACEWAYS LISTED FOR UNDERGROUND USE.

    FIRE AND SMOKE DAMPERS

    1. PROVIDE FIRE DAMPERS IN DUCTS PENETRATING RATED WALLS, FLOORS, OR CEILINGS IN ACCORDANCE WITH THE KENTUCKY BUILDING CODE AND THE INTERNATIONAL MECHANICAL CODE.

    2. PROVIDE SMOKE DAMPERS IN DUCTS PENETRATING SMOKE PARTITIONS OR SMOKE BARRIERS.

    3. PROVIDE COMBINATION FIRE/SMOKE DAMPERS WHERE INDICATED ON THE DRAWINGS, OR BY NOTE.

    4. PROVIDE SLEEVES, FRAMING AND SUPPORTS FOR FIRE DAMPERS IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS.

    5. COORDINATE WIRING OF SMOKE OR FIRE/SMOKE DAMPERS WITH THE ELECTRICAL CONTRACTOR.

    6. FIRE DAMPERS SHALL COMPLY WITH UL STANDARD 555, STANDARD FOR SAFETY FOR FIRE DAMPERS.

    7. SMOKE DAMPERS SHALL COMPLY WITH UL STANDARD 555S, STANDARD FOR SAFETY FOR SMOKE DAMPERS.

    8. INSTALL FIRE DAMPERS, SMOKE DAMPERS, AND COMBINATION FIRE/SMOKE DAMPERS IN ACCORDANCE WITH NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS.

    CHEMICAL TREATMENT

    1. PROVIDE ACCOMMODATIONS FOR CHEMICAL TREATMENT SYSTEMS FOR ALL CLOSED AND OPEN HVAC CIRCULATING WATER SYSTEMS.

    2. INSTALL BLEED CONTROL SOLENOID VALVE ON OPEN COOLING TOWER PUMP DISCHARGE PIPING.3. INSTALL BLEED CONTROL SOLENOID VALVE ON CLOSED CIRCUIT FLUID COOLER SPRAY PUMP

    DISCHARGE PIPING.4. ROUTE TOWER/COOLER BLEED LINE TO FLOOR DRAIN OR OPEN SITE DRAIN CONNECTED TO

    SANITARY SEWER SYSTEM.5. INSULATE AND HEAT TRACE BLEED PIPING EXPOSED TO WEATHER.6. OBTAIN AND EXECUTE CONTRACT WITH CHEMICAL TREATMENT SUPPLIER FOR ONE YEAR OF

    CHEMICAL TREATMENT FOR ALL HVAC CIRCULATING WATER SYSTEMS. CHEMICAL TREATMENT PROGRAM SHALL INCLUDE FURNISHING AND INSTALLING EQUIPMENT, AND CHEMICALS FOR ONE YEAR CONTRACT PERIOD.

    7. COORDINATE POWER WIRING FOR CHEMICAL TREATMENT FEEDERS, CONTROL VALVES, AND OTHER COMPONENTS WITH ELECTRICAL CONTRACTOR.

    START-UP

    1. PROVIDE FACTORY STARTUP FOR ALL MAJOR EQUIPMENT.2. PROVIDE TECHNICAL ASSISTANCE FOR FACTORY STARTUP TECHNICIANS.3. PROVIDE DOCUMENTATION OF STARTUP PROCEDURES FOR FACTORY STARTUP, FACTORY

    ASSISTED STARTUP, AND CONTRACTOR STARTUP PROCEDURES.4. CONTRACTOR STARTUP PROCEDURES SHALL BE CONDUCTED IN ACCORDANCE WITH

    MANUFACTURER'S INSTRUCTIONS.TESTING, ADJUSTING, AND BALANCING

    1. PROVIDE TAB SERVICES VIA INDEPENDENT TAB CONTRACTOR IF SO SPECIFIED. TAB CONTRACTOR SHALL BE CERTIFIED BY NEBB, AABC, TABB OR EQUIVALENT CERTIFICATION AGENCY.

    2. IF CONTRACTOR PERFORMS TESTING, ADJUSTING, AND BALANCING, FIRM AND TECHNICIANS SHALL BE CERTIFIED BY NEBB, AABC, TABB OR EQUIVALENT AGENCY.

    3. PROVIDE TAB REPORT AT CONCLUSION OF TESTING, ADJUSTING, AND BALANCING.

    COMMISSIONING

    1. IF PROJECT COMMISSIONING IS IMPLEMENTED BY THE GENERAL CONTRACTOR , CONSTRUCTION MANAGER, A/E, OR OWNER, THE MECHANICAL CONTRACTOR SHALL PARTICIPATE IN ALL PHASES OF THE COMMISSIONING PROCESS.

    2. THE MECHANICAL CONTRACTOR SHALL PERFORM FUNCTIONAL TESTS AS DIRECTED BY THE COMMISSIONING AGENT.

    3. THE MECHANICAL CONTRACTOR SHALL PROVIDE DOCUMENTATION OF TESTS, MANUALS, AND OTHER MATERIALS AS DIRECTED BY THE COMMISSIONING AGENT.

    4. IF A FORMAL COMMISSIONING PLAN IS NOT IMPLEMENTED, THE MECHANICAL CONTRACTOR SHALL PERFORM FUNCTIONAL TESTS AS RECOMMENDED BY EQUIPMENT MANUFACTURERS, AS SPECIFIED IN THE PROJECT MANUAL, OR AS REQUIRED TO DEMONSTRATE ACCEPTABLE OPERATION OF ALL MECHANICAL SYSTEMS.

    COORDINATED DUCTWORK SHOP DRAWINGS

    1. PREPARE AND SUBMIT COORDINATED SHOP DRAWINGS SHOWING ALL DUCTWORK, AIR-MOVING EQUIPMENT, DUCT ACCESSORIES, HANGERS, SUPPORTS AND RELATED EQUIPMENT.

    2. SHOW ALL OFFSETS, TRANSITIONS, JOINTS AND CONNECTIONS.3. SHOW HORIZONTAL DIMENSIONS FROM CENTER OR SIDE OF DUCT TO COLUMN

    CENTERLINES, FACE OF WALL OR OTHER SUITABLE REFERENCE POINT OR PLANE.4. SHOW TOP OR BOTTOM OF DUCT ELEVATIONS.5. INDICATE PRESSURE CLASS OF DUCTWORK SYSTEMS AND SUB-SYSTEMS.6. SHOW REINFORCEMENT WITH THE USE OF REINFORCEMENT DETAILS AND KEY NOTES.7. SUBMIT SHOP DRAWINGS IN ELECTRONIC FORM, PREFERABLY PDF, SUITABLE FOR

    PLOTTING AT A SCALE OF 1/4" = 1'-0".8. INCLUDE CONTRACTOR'S TITLEBLOCK ON ALL DRAWING SHEETS.9. INCLUDE A KEY PLAN ON EACH DRAWING SHEET, SHOWING THE AREA COVERED BY THAT

    SHEET.10. INDICATE THE SCALE OF THE DRAWING IN NOTE FORM (1/4" - 1'-0") AND WITH A GRAPHIC

    SCALE.

    GENERAL

    1. ALL MECHANICAL WORK SHALL COMPLY WITH THE INTERNATIONAL MECHANICAL CODE AS ADOPTED AND ENFORCED BY THE COMMONWEALTH OF KENTUCKY, AND ANY CODES OR STANDARDS INCLUDED IN THE IMC BY REFERENCE.

    2. THE PRIME MECHANICAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL BE LICENSED BY THE COMMONWEALTH OF KENTUCKY.

    3. THE PRIME MECHANICAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL APPLY FOR, PAY FOR AND OBTAIN ANY PERMITS, INSPECTIONS, AND APPROVALS REQUIRED BY STATE AND LOCAL AUTHORITIES HAVING JURISDICTION.

    RECORD, PROGRESS AND AS-BUILT DRAWINGS

    1. THE MECHANICAL CONTRACTOR AND ALL MECHANICAL SUBCONTRACTORS SHALL MAINTAIN PROGRESS DRAWINGS ON SITE, AVAILABLE TO THE GENERAL CONTRACTOR, ARCHITECT, ENGINEER, AND INSPECTORS HAVING JURISDICTION.

    2. PROGRESS DRAWINGS SHALL INDICATE THE CURRENT STATUS OF THE WORK, AND ANY DEPARTURES FROM THE CONTRACT DRAWINGS DUE TO CHANGE ORDERS, FIELD DIRECTIVES, OR UNFORESEEN CONDITIONS.

    3. UPON REQUEST, THE CONTRACTOR SHALL PROVIDE COPIES OF THE PROGRESS DRAWINGS TO THE GENERAL CONTRACTOR OR ARCHITECT/ENGINEER.

    4. AT THE COMPLETION OF THE PROJECT, THE MECHANICAL CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS (PROGRESS DRAWINGS AS OF PROJECT COMPLETION) TO THE GENERAL CONTRACTOR FOR SUBMISSION TO THE OWNER. AS-BUILT DRAWINGS SHALL BE COMPLETE, CLEAN AND LEGIBLE.

    WxH SA

    WxH RA

    WxH EA

    CEILING SUPPLY DIFFUSER WITH RUNOUT AND SPIN-IN TAP

    SUPPLY AIR DUCT

    RETURN AIR DUCT

    EXHAUST AIR DUCT

    T THERMOSTAT

    BALANCING DAMPER

    CD-XYYY CFM

    X = NECK SIZE, YYY = AIR FLOW

    RETURN AIR GRILLE OR EXHAUST AIR GRILLE

    WxH SA

    WxH RA

    WxH EA

    SUPPLY AIR DUCT RISER

    RETURN AIR DUCT RISER

    EXHAUST AIR DUCT RISER

    FIRE DAMPER

    NOTE: DUCTS MAY OR MAY NOT BE SHADED ON PLANS

    FIRE DAMPER

    FIRE DAMPER SLEEVE

    V. D. IN DUCTSPIN-IN WITH V. D.

    CLAMP CLAMP

    VOL DPR

    RATED WALL

    VOL DPR

    VOL DPR

    VOL DPR

    VOL DPR

    PROVIDE TURNING VANES IN RECTANGULAR MITERED ELBOWS

    PROVIDE VOLUME DAMPERS IN ALL BRANCH DUCTS OR BRANCH TAKE-OFFS

    SUPPLY DUCT RISER

    RETURN DUCT RISER

    SPLITTER DAMPER

    FLEX DUCT

    SLIP-IN DUCT HEATER

    FLANGED DUCT HEATER

    1.5 D RADIUS ELBOW

    FIRE DAMPER

    FIRE DAMPER SLEEVE

    V. D. IN DUCT

    SPIN-IN WITH V. D.

    CLAMP CLAMP

    VOL DPR

    RATED WALLSUPPLY DUCT RISER

    RETURN DUCT RISER

    FLEX DUCT

    1.5D RADIUS ELEOW

    VAV BOX

    TYPICAL DOCTWORK COMPONENTS ARE SHOWN. FOR MORE DETAIL, CONSULT SMACNA HVAC DUCT CONSTRUCTION STANDARDS.

    PROJECT

    DATE

    CHECKED

    DRAWN

    STA

    MP

    HE

    RE

    (NO

    T F

    OR

    CO

    NST

    RU

    CT

    ION

    )

    RE

    VIS

    ION

    S

    35 P

    ub

    lic

    Squ

    are

    •E

    liza

    bet

    hto

    wn

    , K

    Y •

    42

    70

    1

    Off

    ice:

    (2

    70)

    737

    -42

    26 •

    Fa

    x:

    (270

    ) 7

    37

    -04

    41

    info

    @ic

    on

    eng

    inee

    rin

    g.u

    s

    ICON ENGINEERING AND INSPECTION SERVICES, PLLC HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO

    REPRODUCE, REUSE, OR COPY THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE SPECIFIC

    PROJECT LOCATION NOTED IN THE PROJECT TITLE BLOCK. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT

    THE PRIOR WRITTEN CONSENT OF ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST ICON ENGINEERING AND

    INSPECTION SERVICES, PLLC RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR

    REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN ICON ENGINEERING AND INSPECTION SERVICES, PLLC.

    M-000

    MECHANICALNOTES

    2019-1576

    VW

    VW

    8/23/2019

    95

    % R

    EV

    IEW

    SP

    EC

    TR

    AL

    EA

    F

    170 B

    UD

    CO

    LA

    NE

    EL

    IZA

    BE

    TH

    TO

    WN

    , K

    Y 4

    2701

    SCALE: 1/4" = 1'-0"

    DETAIL - DUCTWORK LAYOUT

    No.

    Descriptio

    nD

    ate

    MECHANICAL

  • MECHANICAL ABBREVIATIONS

    ABV ABOVE

    AFMS AIR FLOW MEASURING STATION

    AMB AMBIENT

    APD AIR PRESSURE DROP

    BD