Improved RRI PerformanceImproved RRI Performance
for NOx Control in Coalfor NOx Control in CoalFired Utility BoilersFired Utility Boilers
M. Cremer, D. Wang D. BollReaction Engineering International AmerenUE
E. Schindler E. VsquezRJM Corporation RMT, Inc., Alliant Energy Corp.
US DOE Conference on SCR/SNCR for NOx Control
Pittsburgh, PAOctober 29-30, 2003
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
2/18
Presentation OutlinePresentation Outline
RRI Background
Measured performance Impact of deeper staging
Potential in other unitsEdgewater Unit 4
205 MW cyclone
RRI Operating Costs
Summary
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
3/18
RRI BackgroundRRI Background
High temperature,fuel-rich conditions
Synergism withstaging and RRI
Avoids ammonia slip
Potential for
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
4/18
Demonstration ResultsDemonstration Results
B L En g l a n d U n i t 1 ( Co n e c t i v )
130 MW cyclone, 0.55 lb/MBtu
RRI: 30% NOx reduction,
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
5/18
As Good As it Gets?As Good As it Gets?
0
0.2
0.4
0.6
0.8
1
1.2
1.4
NOx(lb/MBtu
)
Baseline OFA OFA +RRI
Predictions
Measurements
Sioux Unit 1 Results
RRI+OFA: 0.27 lb/MBtu
Predictions consistentwith measurements
Can RRI do better in
Sioux?
Other units?
What NOx emissions can be expected bycombining RRI with deeper staging?
Can better NOx reductions be achievedwith RRI in other units?
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
6/18
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
7/18
RRI in Sioux Unit 1RRI in Sioux Unit 1
500 MW Cyclone500 MW CycloneNOx (ppm)
SR=0.95, OFA
0.41 lb / MBtu
SR=0.90, OFA
0.28 lb / MBtu
SR=0.90, OFA+RRI
0.18 lb / MBtu
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
8/18
Edgewater Unit 4Edgewater Unit 4Alliant EnergyAlliant Energy
330 MW, seven barrels,single wall-fired
SmartBurnSM technology
Front and Rear Wall OFA
PRB/Bituminous blend
NOx 0.45 lb/MBtu
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
9/18
RRI EvaluationRRI Evaluation
Edgewater Unit 4Edgewater Unit 4
0
500
NOx (ppm)
Pre RRI
Post RRI
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
10/18
Predicted RRI PerformancePredicted RRI PerformanceEdgewater Unit 4Edgewater Unit 4
350
550
750
950
1150
1350
1550
1750
620 640 660 680 700 720
Elevation (ft)
NOxM
assFlow
(lb-N
O2/hr)
Baseline RRI 1 RRI 2 RRI 3 RRI 4
Lower
Barrels
Upper
Barrels
OFA
Impact of injector
location and droplet size
NOx = 52%
52% NOx reduction to 0.22 lb/MBtu,
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
11/18
205 MW Cyclone205 MW Cyclone
Opposed wall-fired, fourscroll burner barrels
Front and Rear Wall OFA
Bituminous Coal
Large residence time
NOx ~ 0.6 lb/MBtu
1.2 lb/MBtu prior to OFA Barrel EL 406
OFA EL 908
Large residencetime in fuelrich zone
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
12/18
Predicted PerformancePredicted Performance
205 MW Cyclone205 MW Cyclone
0
700
NOx (ppm)
Pre RRI Post RRI
57% NOx reduction
from 0.61 lb/MBtufull load baseline
Post RRI
0
200
NH3 (ppm)
< 1 ppm NH3
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
13/18
NSR DependenceNSR Dependence
RRI in 205 MW CycloneRRI in 205 MW Cyclone
30%
35%
40%
45%
50%
55%
60%
0 0.5 1 1.5 2 2.5
Normalized Stoichiometric Ratio (NSR)
NOxReductionPerce
ntage RRI 3 Full Load09
RRI 3 Full Load095
41% reagent utilization at NSR=1
RRI performance increases with staging level
57% NOx reduction to 0.26 lb/MBtu at NSR=2 Best performance with 12 injectors at two elevations
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
14/18
Overall ResultsOverall Results
0
0.10.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
NOx(lb/
MBtu)
OFA only
OFA+RRI
Sioux 1 Edgwtr 4 205 MW
0.95 0.90 0.90 0.80 0.95 0.90SR
Unit
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
15/18
Approximate RRI CostsApproximate RRI Costs
0
300
600
900
1200
1500
1800
Sioux 1 Edgwtr 4 205 MW
Unit
$/ton NOx
removedRea g ent Co sts
(Assumes $0.80 per
gallon 50% urea)
Capital Costs consistent with SNCR
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
16/18
SummarySummary
RRI combined with deeper staging will likely
achieve NOx
-
7/30/2019 40753 REI Netl SCR Workshop 1003 (1)
17/18
AcknowledgementsAcknowledgements
The authors would like to acknowledgeEPRI and the U.S. Department of
Energy (USDOE) for their support ofthe original development of RRI. USDOE support under contract number
DE-FC26-00NT40753 (Bruce Lani,Project Manager).
-