4 FLOOR TRUNKING & ACCESSORIES - POWER CENTER · 4 FLOOR TRUNKING & ACCESSORIES 4-1 Access Floor...
Transcript of 4 FLOOR TRUNKING & ACCESSORIES - POWER CENTER · 4 FLOOR TRUNKING & ACCESSORIES 4-1 Access Floor...
FLOOR TRUNKING & ACCESSORIES4 4-1 Access Floor Trunking and Accessories
4-2 Flushfloor Trunking and Accessories4-3 Underfloor Trunking and Accessories
SEC4.indd 2 5/16/09 4:00:41 PM
FLO
OR
TRU
NKI
NG
&
ACCE
SSO
RIES
4
Fittings High rise intersection(supplied with couplers)
Low rise intersection(supplied with couplers)
High rise tap-off
Low rise tap-off
Three compartment trunking allows for cablemanagement within most floor voids with a highdegree of flexibility
Trunking Lengths(supplied in 2 meter lenghts with 2 x 1 metrecovers, cover fixing clips and trunk couplers)
Fittings
Flat bend(supplied with couplers)
Rising elbow(supplied with couplers)
Blank end(supplied with fixings)
4-1 ACCESS FLOOR TRUNKINGAND ACCESSORIES
SIZE ITEM NUMBER
W x H
240 x 38mm 23011001
360 x 38mm 23011002
SIZE ITEM NUMBER
W x H
240 x 38mm 23011230
360 x 38mm 23011231
SIZE ITEM NUMBER
W x H
240 x 38mm 23011240
360 x 38mm 23011241
SIZE ITEM NUMBER
W x H
240 x 38mm 23011250
360 x 38mm 23011251
SIZE ITEM NUMBER
W x H
240 x 38mm 23011260
360 x 38mm 23011262
SIZE ITEM NUMBER
W x H
240 x 38mm 23011201
360 x 38mm 23011202
SIZE ITEM NUMBER
W x H
240 x 38mm 23011210
360 x 38mm 23011211
SIZE ITEM NUMBER
W x H
240 x 38mm 23011220
360 x 38mm 23011221
Other sizes are available on request, Please consult our sales department.59
SEC4.indd 3 5/16/09 4:00:43 PM
FLOO
R TRUN
KING
& ACCESSO
RIES
4
Product definition
Available in 2 metre 3 compartment length with 2*1 metre covers which are secured using push-on clips (all trunking is unassembled) and supplied with a joint range of accessories in “high” or “low” rise options depending on size of the floor void.
Material specification
All trunking components are manufactured from pre-galvanised sheet steel to BS EN 10142 in the following thicknesses:Trunking body: 1.0 mmTrunking cover: 1.0 mmAccessories: 1.2 mm
Trunking body and cover are return edge style joints are “fish plate” type and supplied with fixing nuts and bolts.Trunking lengths are manufactured to a tolerance of +0 mm/-2 mm on a 2 000 mm length.
Compartment cross-section
Trunking compartment cross-section240*38 mm 2 980mm²360*38 mm 4 480 mm²
Intersection capacity
Expressed as a percentage of main trunking compart-ment capacity 240*38 mm low rise 65%360*38 mm low rise 65%240*38 mm high rise 100%360*38 mm high rise 100%Tap-off boxes allow 100% of through capacity of the trunking used
Minimum floor void
Low rise 57 mmHigh rise 83 mmRising elbow:Height 83 mmDepth 83 mm
Installation
Trunking and accessories are designed to be laid flat on the floor and should not be used in any other way.
57(o
ver f
ixin
gs)
57(o
ver f
ixin
gs)
83(o
ver f
ixin
gs)
Low rise tap-off
High rise tap-off
High rise intersection
Low rise intersection
306
402522
Dimensions (mm)
Trunking
Flat bend and rising elbow
288
408
40 O
/A
244 O/A12080 80 80
120 120
364 O/A
429
549
402522
248
368
300
83(o
ver f
ixin
gs)
43(o
ver f
ixin
gs)
288408
545665
H
W
4-1 ACCESS FLOOR TRUNKINGAND ACCESSORIES
Other sizes are available on request, Please consult our sales department. 60
SEC4.indd 4 5/16/09 4:00:46 PM
FLO
OR
TRU
NKI
NG
&
ACCE
SSO
RIES
4
FF3001 with FF3021 and FS300G
326
195
110
26
65
inte
rnal
11080
Trunking
4-2 FLUSHFLOOR TRUNKINGAND ACCESSORIES
Three compartment trunking for the laying ofcables into a screeded floor, which providesaccess to the cables once final screed is in place
Trunking lenghts(supplied with covers and couplers)
Fitings
Universal intersection fitting(supplied with cover, 2 coupler sets,1 blanking plate and a terminator assembly)
Rising elbow to skirtign trunking(supplied with underfloor trunking adaptor)
Terminator assemblies
Blanking plate
Conduit adaptor
Underfloor adaptor
Holding down bracket
Trunking coupler
Intersection coupler
SIZE ITEM NUMBER
2.4 m 23021001
1.8 m 23021002
1.2 m 23021003
0.6 m 23021004
ITEM NUMBERS
23021201
ITEM NUMBER
23021220
ITEM NUMBER
23021225
ITEM NUMBER
23021230
ITEM NUMBER
23021235
ITEM NUMBER
23021240
ITEM NUMBER
23021245
ITEM NUMBERS
23021210
Other sizes are available on request, Please consult our sales department.61
SEC4.indd 5 5/16/09 4:00:48 PM
FLOO
R TRUN
KING
& ACCESSO
RIES
4
4-2 FLUSHFLOOR TRUNKINGAND ACCESSORIES
Flushfloor Service Unit
FS300G with SP102F, SP201P and SP203P
A three compartment service unit designed to fitdirectly into the flushfloor trunkingSupplied as one complete unitIncludes reversible lid with cables exits and litinghandle, carpet trim frame, and modular 300 mmtrunking lid fitment65 mm deep flushfloor applications are restrictedto 26 mm below accessory plate
Flushfloor sevice unit300 mm deep flushfloor service unit (supplied empty)
Accessory plates
Twin switched13 A socket outlet(side wired)
Twin unswitched13 A non-standardclean earth socket outlet(round earth pins)
Blank plate
4 x LJ6c/RJ45 plateAperture size:37 x 22.3 mm
4 x 50 Ohm BNC outlet
2 x 25 pin ‘D’ type outlet
2 x single BT(1) LJ2 plate(not suitable for standardsingle gang socket outlets)
4 x ST FNBP type outlet
ITEM NUMBER
23111001
ITEM NUMBER
23111201
ITEM NUMBER
23111202
ITEM NUMBER
23111205
ITEM NUMBER
23111210
ITEM NUMBER
23111212
ITEM NUMBER
23111213
ITEM NUMBER
23111220
ITEM NUMBER
23111221
Other sizes are available on request, Please consult our sales department. 62
SEC4.indd 6 5/16/09 4:00:50 PM
FLO
OR
TRU
NKI
NG
&
ACCE
SSO
RIES
4
4-2 FLUSHFLOOR TRUNKINGAND ACCESSORIES
Product definitionA screed floor system which incorporates an extruded aluminium screed edge over a steel base trunking. The covers rest on a reversible plastic edge gasket and are retained by quarter turn fasteners in addition,the covers are secured with temporary fixings for transit and installation.Trunking jointing pieces incorporate alignment and earthing features Trunking floor fixing brackets are height adjustableIntersections are provided with comprehensive cross-over units in addition to centrally placed lid support pillars
Material specificationAll trunking components are manufactured from hot dipped pre-galvanised sheet steel to BS EN 10142 in the followingThicknesses:Trunking body: pre-galvanised sheet steel – 1.4 mmTrunking over: pre-galvanised sheet steel – 2.0 mmCover reinforcement: pre-galvanised sheet steel – 1.2 mmDividers: pre-galvanised sheet steel – 1.2 mmFloor service unit: pre-galvanised sheet steel Universal intersection fitting: pre-galvanised sheet steel
Aluminium edge strip to BS 1474Gasket formed of extruded PVCTrunking lengths are manufactured to a tolerance of +0 mm/-2 mm on a 2 400 mm length
Compartment cross-sectionCompartment sizeOuter (each) 2 860 mm²Centre 2 080 mm²
Intersection capacityThere is no reduction in cable permitted under at flushfloor trunking intersections
Trunking loading These will be those loads permitted under offices to BS 6399 part 1:1984Pillar supports are provided in the intersection units
Service unit lid loadingComplies with raised access floors specification as specified in PSA MOB PF2 PS/SPU (p4.01/p4.02). tests show that no permanent deformation occurs at point loading of up to 230 kg
InstallationFlushfloor trunking should be installed on to a ribbon screed,using the height adjustable fixing to secure to the floor. Packing underneath trunking should always be used if the trunking is raised off the screed .The trunking cover is supplied in place and sealed with tape which should remain until after all screeding operations are complete. All jointing pieces and mounting brackets may be attached externally The remaining screed can be used as a datum line. After screed has set remove the temporary fixing screws which locate cover on to base
Piercing and technical details for accessory plates
65 mm deep fushfloor applications are restricted to 26 mm below accessory plate
312
302
225300
326
195
195
110
26
65
inte
rnal
11080
186
150
80
65
Accessory plates
Service Unit
Trunking
4 to
10
mm
adj
ustm
ent
for f
loor
fini
sh th
ickn
ess
Truncking with rising elbow
Note: Sockets must be side wired
8.8
9.7
3.7
22.3
BNCtype outlet
LJ6C/RJ45 (shuttered)type outlet
Other sizes are available on request, Please consult our sales department.63
SEC4.indd 7 5/16/09 4:00:51 PM
FLOO
R TRUN
KING
& ACCESSO
RIES
4
4-3 UNDERFLOOR TRUNKINGAND ACCESSORIES
UF391 with UFS391G and B309144
150225
25 38 H
W
A comprehensive system of three compartmentducting which allows service to be suppliedunobtrusively in a screeded floor
Ducting lenghts(supplied in 3 metre lenghts with couplers)
Fittings
Intersection box (333 x 333 mm)65 mm deep box with aluminium inner frame andsteel lid to support floor finish, A separate plastictrim is included for fitting when laying carpet
Rising elbowFrom underfloor to75 mm deep surfacecable trunking
CouplersSupplied complete withfixing screwsand earth bonding link
End stopSupplied complete withfixing screws
SIZE ITEM NUMBER
W x H
150 x 25mm 23031001
225 x 25mm 23031002
225 x 38mm 23031003
SIZE ITEM NUMBER
W x H
150 x 25mm 23031201
225 x 25mm 23031202
225 x 38mm 23031203
SIZE ITEM NUMBER
W x H
150 x 25mm 23031210
225 x 25mm 23031211
225 x 38mm 23031212
SIZE ITEM NUMBER
W x H
150 x 25mm 23031220
225 x 25mm 23031221
225 x 38mm 23031222
SIZE ITEM NUMBER
W x H
150 x 25mm 23031230
225 x 25mm 23031231
225 x 38mm 23031232
Other sizes are available on request, Please consult our sales department. 64
SEC4.indd 8 5/16/09 4:00:53 PM
FLO
OR
TRU
NKI
NG
&
ACCE
SSO
RIES
4
4-3 UNDERFLOOR TRUNKINGAND ACCESSORIES
Underfloor service unit
Three compartment service unit Includes a 65 mm deep box, reversible lid withcable exits, lifting handle and carpet trim frameApplications are restricted to 26 mm belowaccessory plateThe unit is supplied with a screeding cover platewhich is removed sfter screeding and replacedby the lid/trim pack supplied
Underfloor service units(supplied empty)
Accessory plates
Twin switched13 A socket outlet(side wired)
Twin unswitched13 A non-standardclean earth socket outlet(round earth pins)
Blank plate
4 x LJ6c/RJ45 plateAperture size:37 x 22.3 mm
4 x 50 Ohm BNC outlet
2 x 25 pin ‘D’ type outlet
2 x single BT(1) LJ2 plate(not suitable for standardsingle gang socket outlets)
4 x ST FNBP type outlet
SIZE ITEM NUMBER
302 x 250 x 65 mm
For use with 150 x 25 mm underfloor ducting23121001
302 x 250 x 65 mm
For use with 225 x 25 mm underfloor ducting23121002
302 x 250 x 65 mm
For use with 225 x 38 mm underfloor ducting23121004
302 x 250 x 65 mm
Fitted with blank plates for conduit23121010
302 x 250 x 80 mm
Fitted with blank plates for conduit23121015
302 x 250 x 100 mm
Fitted with blank plates for conduit23121018
ITEM NUMBER
23121201
ITEM NUMBER
23121202
ITEM NUMBER
23121205
ITEM NUMBER
23121210
ITEM NUMBER
23121212
ITEM NUMBER
23121213
ITEM NUMBER
23121220
Item Numbers
23121221
Other sizes are available on request, Please consult our sales department.65
SEC4.indd 9 5/16/09 4:00:55 PM
FLOO
R TRUN
KING
& ACCESSO
RIES
4
4-3 UNDERFLOOR TRUNKINGAND ACCESSORIES
Product definitionA screeded floor system available in three sizes of three compartment ducting complying with BS 4678, part2: 1973 and utilizing a service outlet unit similar to the cavity and flush floor types
Material specificationAll trunking components are manufactured from pre-galvanised sheet steel to BS EN 10142 in the following thickenesses:Top section: 1.2 mmBase: 1.0 mmFillet: 1.0 mm
Compartment cross-section
Ducting compartment sizes25*150 1 140 mm²25*225 1 760 mm²38*225 2 540 mm²
Intersection capacityExpressed as a percentage of main trunking compart-ment capacity25 mm deep trunking 100%38 mm deep trunking 71%
Service unit lid loadingComplies with raised access floors specification as specified in PSA MOB PF2 PS/SPU (P4.01/P4.02). tests show that no permanent deformation occurs at point loading of up to 230 kg.
Installation
It is recommended that you should lay expanded metal mesh over the ducting prior to screeding to specified thickness. After screeding remove underfloor service unit screeding plate and replace with lid/trim pack which is supplied.
Piercing details for accessory plates
65 mm deep flushfloor applications are restricted to 26 mm below accessory plate.
8.8
9.7
37
22.3
BNCtype outlet
LJ6C/RJ45 (shuttered)type outlet
186Accessory Plates
80
250
150225
225
4 to
10
mm
adu
stm
ent
for f
loor
fini
sh th
ickn
ess
65
195
Service box
Note: Sockets must be side wired
Ducting with rising elbow
302
282
15 m
m a
dust
men
t for
flo
or ir
regu
larit
y
25 38
75
150
100
(for 2
5 m
m d
eep
truck
ing)
113
(for 3
8 m
m d
eep
truck
ing)
25 38
H
W
Other sizes are available on request, Please consult our sales department. 66
SEC4.indd 10 5/16/09 4:00:57 PM