4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor...

30
ASSEMBLY INSTRUCTIONS BIOCLIMATIC PERGOLA 4 DUPLEX COLUMNS P-190

Transcript of 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor...

Page 1: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS BIOCLIMATIC PERGOLA

4 DUPLEX COLUMNS P-190

Page 2: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate
Page 3: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

INDEX

01 INSTALLATION 02

We do not provide the screws for fixing-anchoring to the wall and/or foundations. The fitter must choose the adequate rod/screw/plug/nut/washer system for fixing and flushing to the foundations ad/or wall, based on the nature of these surfaces. In any case, the screws must be in stainless steel.

1.1 INSTALLING THE FIXATION FOR THE COLUMN BASE 02 1.2 FIXING COLUMNS 04 1.3 FIXING LATERAL BEAM 05 1.4 JOINING LATERAL BEAM AND COLUMNS 06 1.5 JOINING THE CENTRAL BEAM 07 1.6 FIXING CAPS OF THE OPENING AND CLOSING BEAM 08 1.7 JOINING THE SURFACE MANIFOLDS 09 1.8 INSTALLING THE SLATS 10 1.9 INSTALLING THE TRANSMISSION PLATE 12 1.10 INSTALLING THE “U” PROFILE 13 1.11 MOTOR INSTALLATION 14

02 ELECTRICAL CONNECTIONS 15

The connection of the electrical installation must be in compliance with the rules and regulations of each country (Low voltage electrotechnical regulation).

2.1 ELECTRICAL DIAGRAM OF COMPONENTS 15

03 INSTALLING THE COLUMN CAP 18

04 SWITCHBOARD PROGRAMMING (factory set up) 19

4.1 ADVANCED MOTOR PROGRAMMING (factory set up) 19

05 MAINTENANCE 20

Before assembling, please read the maximum tightening torque for each type of screw, as indicated in this section.

— ANNEX A - DISMANTLING AND DISPOSING OF PRODUCT PACKAGING AND COMPONENTS

AT THE END OF THEIR USEFUL LIFE 21— ANNEX B - CERTIFICATE OF GUARANTEE 25

— PERGOLA ASSEMBLING CHECKLIST 27

Page 4: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

01 INSTALLATION

1.1 INSTALLING THE FIXATION FOR THE COLUMN BASE

DIAGONAL EXACT

Measure the foundation in order to make sure that the levelling is correct.

Install the base fixings using M-12 screws (not included), with a quality of at least AISI 304 (stainless steel), leaving all bases properly levelled.

NOTE: It is possible to attach the bases to the ground at the ground at the end of the structure assembly. This will

facilitate the mounting process.

Once the column bases are installed in place, measure the diagonal lines to ensure both distances are equal.

- Recommended installation is against a wall with reinforced concrete floor of at least 150 mm thickness (or surface of equivalent strength) by means of 12 mm stainless steel fittings (not included).- Leave a 100 mm space above the beam so the slats can turn.

Page 5: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

3

LEFT BEAM RIGHT BEAM

250,00

250,

00

28,0

0

28,00

144,

00

144,00

Ø12,00

OPENING BEAM

CLOSING BEAM

OPENING SURFACE MANIFOLD

CLOSING SURFACE MANIFOLD

C COLUMN

A COLUMN

D COLUMN

B COLUMN

CENTRAL BEAM

Page 6: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

C COLUMN

A COLUMN

D COLUMNB COLUMN

ULS (ISO 7380) A2 M6x16Code 051103

1.2 FIXING COLUMNS

Join the A, B, C and D columns to the bases attached to the foundation.

Page 7: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

5

C COLUMN

A COLUMN

D COLUMN

LEFT BEAM

1

2 3

45

RIGHT BEAM

B COLUMN

1.3 FIXING LATERAL BEAM

Join the LEFT beam to columns A and D.

Joint the RIGHT beam to columns B and D.

Follow the screwing sequence indicated in the image.

Page 8: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

C COLUMN

A COLUMN

CLOSING BEAM

OPENING BEAM

D COLUMN

LEFT BEAM

RIGHT BEAM

B COLUMN

1.4 JOINING LATERAL BEAM AND COLUMNS

Join the CLOSING bear to columns A and B.

Join the OPENING bear to columns C and D.

Page 9: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

7

CLOSING BEAM

OPENING BEAM

CENTRAL BEAM

ULS (ISO 7380) A2 M6x16Cod. 051103

VA-A WS9350 A4 M8x110Code 050136

1.5 JOINING THE CENTRAL BEAM

Join the CENTRAL beam with the OPENING and CLOSING beams.

Page 10: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

TAPA VIGA CIERRE

TAPA VIGA APERTURA

1.6 FIXING CAPS OF THE OPENING AND CLOSING BEAM

Join the CLOSING beam to columns A and B.

Join the OPENING beam to columns C and D.

Page 11: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

9

SEALANT

Before continuing the installation, create a groove for the water run-off at each end of both manifolds (use a hammer and a flat screwdriver).

1.7 JOINING THE SURFACE MANIFOLDS

Apply the provided sealant between the contact sides of the OPENING and CLOSING beams and their correspond-ing surface manifolds.

The opening and closing surface manifolds will be joined, screwing them to the beams.

ATTENTION: Do not bypass this step, it is very important to seal the manifold joint properly (sealant provided).

OPENING CLOSING

130,00 125,00

130,00 125,00

Page 12: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

16 cm

1.8 INSTALLING THE SLATS

When the structure has been assembled, and before installing the slats, place the 16,3 mm plastic rimmed caps in the machined beam holes where no LEDs are going to be installed.

Start the slat installation from the opening side.

When reaching a hole for LED slats, connect the connector and insert it inside the beam (as shown in the images below). Then install the 16,3 rimmed plastic cap.

Prepare the fixed axles for the left side of the slats and the mobile axles for the right side.

Page 13: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

11

To install the slats, they must be tilted with the end caps facing down, inserting the fixed axle first (left) and then the mo-bile one (right).

Using a Nº 4 Allen key, pull back the axle until it stops in the grooved hole.

When it stops, fasten the screw of the cap.

Turn the axle 180º and insert the safety screw.

Page 14: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

BOTTOMRespect the transmission plate position

NUT M6 A2 DIN 985Code 051048

RIMMED CAP 6,3Code 051033 ULS (ISO 7380) A2 M6x16

Code 051103

ATTENTION: When installing the plate in the slats, do not tighten the screw nuts too much, so they are set without tightening. Thus the plate can perform the opening and closing movements manually with no friction whatsoever.

1.9 INSTALLING THE TRANSMISSION PLATE

With the slats already in the structure, install the two transmission plates in the slat end caps. One of the slats will include an integrated support with a motor fixing stud, It is necessary to know the side of the pergola where the motor will be installed, so the plate can be mounted on that side.

Install the two plates simultaneously if possible. Start by fixing the first, the last and the centre slats to the transmission plate. This facilitates the rest of the installation.

Join the plates to the end caps with their corresponding ULS (ISO 7380) A2 M6x16, screws, 6,3 mm rimmed plastic caps and M6. DIN 985 nut.

Page 15: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

13

SEALANT

Check that all the “U” profile holes match the M6 machined ones on the beam. If all of them match, apply the sealant be-tween the “U” profile and the beam after screwing the profiles with the ULS (ISO 7380) A2 M6x16.

Use the sealant provided to seal the “U” profiles to the beams and the joints that could suffer water leaks.

1.10 “U” PROFILE INSTALLATION

Start by installing the “U” profile with the pre-installed motor on the CENTRAL beam. To do this, insert the profile end through the draining hole machined on the OPENING beam. Proceed in the same manner with the “U” profiles of the LEFT and RIGHT beams, inserting one end of the profile through the draining hole machined on the C and D columns.

SCREWHOLE

SCREWHOLE

“U” PROFILE

SEALANT

Page 16: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

AB

Steps to install the motor:

1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A).

2 Insert the tip of the motor piston rod into the transmission plate stud (B).

3 Mount the nut on the transmission plate stud so the motor does not come out (B).

4 Lastly, the motor support is mounted again on the “U” profile its 2 screws (A).

1.12 MOTOR INSTALLATION

The motor is already pre-installed in the “U” profile. The motor piston rod needs to be halfway through its stroke so it can be inserted into the plate stud and the support with the engine can be taken to the profile position.

Page 17: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

15

02 ELECTRICAL CONNECTIONS

¡ATTENTION! The reception of the operators can be reduced or cancelled by the emission of frequencies that are issued in the same range as our automatisms.v

The connection of the electrical installation must be in compliance with the rules and regulations of each country (Low voltage electrotechnical regulation).

The perimeter cabling for the electrical and sound installations will be passed throuth the beam and column spaces.

The cable of the motor will go through the “U” profile towards the end where the electric connection will be performed, making a loop at the motor outlet and passing it under the support, so it cannot be pinched by the transmission plate when the assembly moves.

Complete the electric connections of the pergola according to the instructions and considering that both the motor and the LEDs run with a 24V voltage. For this reason, it is necessary to use the power soure and switchboard provided for the pergola operation.

For greater safety, it is necessary to ground the pergola, and install a watertight box outside it in order to house all the connections and protect the automatic systems.

1 + POSITIVE 24V

2 - NEGATIVE 24V

3 MOTOR +

4 MOTOR -

2.1 ELECTRICAL DIAGRAM COMPONENTS

Central for pergola RTS, only MOTOR.

3 14 2

PROG.IN

POWER SUPPLY24V

230VMOTORL

N

+ +- -

POWERSOURCE

Page 18: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

Central for pergola system io, with LEDs and rain sensor

OPTIONRAIN SENSOR

OPTIONLEDS

PR

OG

.S

1

ON

1 2 3 4 5

OFF

PO

WER

SU

PP

LY

OU

TPU

T Vd

c

OU

TPU

T Vd

cO

UTP

UT

Vdc

S1

S1

S2

S2

S2

24 Vdc

24 Vdc

RAINSENSOR

12345

24 Vdc 230VL

N

+

+

+

-

-

-

LED TUBEWHITE STRIPETRANSPARENT

REDBLACK

POWERSOURCE

WHITE LEDRECEIVER io

EXTENSIONMOTORISATION

S1

EXTENSIONMOTORISATION

S2

¡WARNING! INSTALL THE POLARISED COMPO-NENTS CORRECTLY

OUTLED

IN

Page 19: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

17

Central for pergola system io, with LEDs, rain and wind sensor

OPTIONRAIN SENSOR

+WIND SENSOR

OPTIONLEDS

LED TUBEWHITE STRIPETRANSPARENT

REDBLACK

PR

OG

.S

1 ON

1 2 3 4 5

OFFP

OW

ER S

UP

PLY

OU

TPU

T Vd

c

OU

TPU

T Vd

cO

UTP

UT

Vdc

S1

S1

S2 S2

S2

24 Vdc 230V

230V

L

L

N

N

+-

POWERSOURCE

EXTENSIONMOTORISATION

S1

EXTENSIONMOTORISATION

S2

¡WARNING! INSTALL THE POLARISED COMPO-NENTS CORRECTLY

BLACK 1

BLACK 2

24 Vdc

RAINSENSOR

12345

+-

WHITE LEDRECEIVER io

OUTLED

IN

Page 20: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

03 INSTALLING THE COLUMN CAP

After the electric connections are completed, installing the column caps is the last stage left. To do this, the caps will be screwed to the inner reinforcements using the ULS (ISO 7380) A2 M6x16 mm screws.

When all the column caps have been installed, it will be neces-sary to seal their joints with the sealant provided, as mentioned before, one of the caps has 3 glands to take the cables out to the switchboard.

SEALANT

VERY IMPORTANT: The pergola switchboard comes completely programmed from the factory and with complete stroke ends, so you should NOT MANIPULATE the components or change the switchboard set up, as this could cause operation faults in the pergola and its automation systems.

Central for pergola system io, with LEDs,and wind sensor

OPTIONWIND SENSOR230V

OPTIONLEDS

TUBE LEDWHITE STRIPETRANSPARENT

REDBLACK

PR

OG

.S

1 ON

1 2 3 4 5

OFF

PO

WER

SU

PP

LY

OU

TPU

T Vd

c

OU

TPU

T Vd

cO

UTP

UT

Vdc

S1

S1

S2 S2

S2

24 Vdc 230VL

N+-

POWERSOURCE

EXTENSIONMOTORISATION

S1

EXTENSIONMOTORISATION

S2

¡WARNING! INSTALL THE POLARISED COMPO-NENTS CORRECTLY

24 Vdc

12345

+-

WHITE LEDRECEIVER io

OUTLED

IN

Page 21: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

19

04 SWITCHBOARD PROGRAMMING (FACTORY SET UP)

4.1 ADVANCED PROGRAMMING THE MOTOR (factory set up)

1 Press the PROG. button on the electronic plate for over 2 seconds, until the S1 and S2 light-up indicators flash (raising and lowering movement of the pergola.

5 Press the raise button to check the rotation direction: if the automatic product opens itself, the rotation direction is correct. If the automatic product closes itself, the rota-tion direction is incorrect. Press the “mu” button until the automatic product raises and the lowers itself. This will modify the rotation direction.

6 Press the “RAISE” button to check the rotation direction.

2 Select desired extension by briefly pressing the PROG. button. The light-up indicator corresponding to the selected extension will flash. If the plate only has a per-gola, continue to the next stage (resending information to the selected extension).

3 Select the desired channel in the control points Situo 1 io and Situo 5 io.

4 Press “RAISE” and “LOWER” simultaneously until you see a response from the selected pergola.

CONFIGURED

PROG.S1

S2

PROG.S1

S2>2s

CONFIGURED

PROG.S1

S2

PROG.S1

S2>0.5s

select

1

2

3

4

CONFIGURED

<

<

1

2

3

4

<

1

2

3

4

Page 22: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

SCREWS HARDNESS CATEGORY 70

THREAD µges.MA TIGHTENING TORQUE (Nm)

M5 0,2 5,7

M6 0,2 10

M8 0,2 24

05 MAINTENANCE

For best use and extended durability of your pergola, it is recommended to carry out regular maintenance and services at least once a year, or even more often depending on the wind fatigue at the installation site.

To prevent corrosion, it is recommended to periodically clean gutters and sections with neutral soap. The minimum fre-quency is once a year, and must be increased for cloths exposed to aggressive environments (marine, industrial, airborne dust particles, etc.). It is important to rinse thoroughly with water, after using detergents, to avoid the formation of salts

on the surface of the sections.When properly done, this periodical cleaning removes from the surface of the cloth the exogenous agents that can attack the coating and aluminium, extending the life of the sections and their aesthetic performance.

Inspection of seals, revision of the electrical installation, as well as a review of the tightening of screws according to the tightening torques (standard metric thread) set forth in the attached table.

7 Press “RAISE” and “LOWER” simultaneously. do not interrupt the movement. The motorisation will automati-cally find its upper and lower limit switches.

8 Move the pergola into the desired position in case of frost/snow using long presses on the “RAISE” and “LOWER” buttons.

9 Confirm the adjustments by pressing “my” for over 2 seconds (resending information to the selected exten-sion)

10 Briefly press the PROG. button on the rear part of the control point, until you see a response from the selected extension. The product will have memorised the posi-tions of its limit switches.

<

<

1

2

3

4

CONFIGURED

<

<

1

2

3

4

my

1

2

3

4

>2s

Prog

Page 23: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

21

IMPORTANT: packaging should be recycled by the qualified professional who installed the product..

OUR COMMITMENT TO PROTECTING THE ENVIRONMENT

One of Giménez Ganga’s objectives is to maintain socially responsible behaviour. Our commitment to the environment involves continual improvements to the measures adopted for combating climate change.

Measures that we feel are essential for the achievement of our objectives are promoting responsible care of the environ-ment, complying with legal and legislative requirements that apply to our products and encouraging energy savings in all of our projects.

We recommend that the product packaging should be recycled in a responsible manner:

• Dispose of waste in compliance with current legislation:

- Directive 94/62/CE, for packaging and packaging waste - Law 11/1997, of the 24th April, for packaging and packaging waste.

• Sort the waste by separating it into the different types of materials in order to efficiently dispose of the packag-ing.

• Do not dispose of packaging along with other types of waste. Take it to a collection point for packaging materia designated by the local authorities.

• To minimise the environmental impact of packaging and packaging waste, the composition and natura of our product packaging should be defined, in order to recommend the best means of disposal:

Paper and cardboard: In waste management, recycling of paper and cardboard is of vital importance since up to 70% of the material can be recovered. Paper and cardboard can be disposed of in numerous ways, such as collection by private contractors or delivery to waste treatment centres.

Plastic: Recycling plastic is highly beneficial for the environment and, as such, it is beneficial for every-one’s quality of life, contributing to a major saving of raw material in addition to natural, economic and energy resources. Plastic can be disposed of by private contractors or by delivery to waste treatment centres.

Bubble wrap: It is made of low-density polyethylene, which is 100% recyclable material. For optimal disposal, waste material of this type should be delivered to a treatment centre for plastic waste.

ANNEX A

DISMANTLING AND DISPOSING OF PRODUCT PACKAGING AND COMPONENTS AT THE END OF THEIR USEFUL LIFE

DISPOSING OF PACKAGING

Page 24: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

IMPORTANT: the dismantlement of the product at the end of its useful should be carried out by a qualified professional, To do this, the steps taken to initially assemble the product should be carried out in reverse.

In order to dismantle this product a series of precautionary measures should be taken. Observe the following warnings and specifications. In case of doubt, contact the supplier.

Dismantlement should only be performed by experienced fitters. This manual is not designed for DIY amateurs or trainee fitters.

For further information on these dismantlement instructions, please refer to the installation chapters of this manual, which contain drawings and detailed information.

¡ATTENTION! Proceed with great caution. Use tools which are appropriate for the task and in good condition.

STEP 1Disconnect the electricity. ¡ATTENTION! Shut off the energy supply before disconnecting any cables.

STEP 2Dismantle the motor.

STEP 3Dismantle the transmission plate.

STEP 4Dismantle the slats.

STEP 5Dismantle the drainage channels.

STEP 6Dismantle the rubber parts.

STEP 7Dismantle the clip fasteners on the opening and closing beams.

STEP 8Dismantle the pergola structure by disassembling the interior brackets that fasten the beams to the columns, and the wall fixtures, if there are any.

STEP 9Dismantle the columns and their fixtures.

¡ATTENTION! Make sure that you dispose of all the product’s parts according to the nature of the material.

DISMANTLING AND DISPOSING OF THE PRODUCT

Page 25: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

23

Our products are primarily made of recyclable materials. It is necessary to enquire about the recycling and disposal sys-tems specified by the current local legislation for this type of product.

When electrical or electronic equipment reaches the end of its useful life it should not be disposed of alongside other types of waste. It should be delivered to specific centres that are regulated by local administrations.

Effective separation of waste will avoid any negative consequences for health and the environment that can be produced from poor management of

Illegal disposal of the product may incur serious penalties due to local regulations.

IMPORTANT: respect of this directive will benefit the environment and contribute to the conservation of natural resources and health protection.

This symbol means that the product cannot be disposed of alongside domestic waste as it should be col-lected separately, to be recovered, reused or recycled according to the current local legislation.

In accordance with European Directive 2012/19/UE, waste electrical and electronic equipment (WEEE) can have serious consequences for the environment if it is not managed appropriately. The Directive provides the general framework, valid throughout the European Union, for the removal and recycling of waste electrical and electronic equipment.

COMPONENTS

GA

LVA

NIS

EDS

TEEL

STA

INLE

SS

STE

EL

ALU

MIN

IUM

WEE

E

PLA

STI

C

TEXT

ILE

Cables and LED lines •Watertight box •Caps •Switchboard • •Brackets •Upper brackets •Rubber seal •Motor • • •Profile •Motor brackets •End plates •Screws •

Page 26: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

THE MATERIALS USED IN OUR PRODUCTS OFFER A WIDE VARIETY OF ENVIRONMENTAL ADVAN-TAGES

GALVANISED STEEL

Galvanised steel is a type of steel which undergoes treatment to cover it with several layers of zinc, pro-tecting it and preventing rust. Recycling zinc contributes to a reduction of the demand for new materials

and consequently it provides a large energy saving, thus it is a valuable and sustainable metal. To recycle galvanised steel correctly it should be taken to a collection centre for metallic waste.

STAINLESS STEEL

Stainless steel is a type of iron alloy which contains nickel and chrome to protect it from corrosion and rust. Among its many beneficial qualities are its high temperature resistance and its strength as a mate-

rial. Stainless steel is a “green material”, so can be recycled indefinitely. Its properties make it ideal for exposure to the elements. Trerefore, in order to dispose of stainless steel appropriately it should be taken to a collection centre for specialised waste.

ALUMINIUM

Recycling aluminium provides a plethora of environmental benefits. Using recycled aluminium offers a 95% saving of the energy used in the production of raw materials, since it is entirely recyclable and can be recycled indefinitely. Furthermore, recycling aluminium is cost-effective both from a technical and

economical perspective. Consequently, in order to dispose of this material appropriately it should be taken to a collec-tion centre for specialised waste

CABLES

Recycling electrical cables will avoid the contamination that they can cause. Recycling them means that the copper, aluminium and brass cables can be reused once the plastic covering is removed. Electrical and electronic waste should be taken to clean points to be recycled correctly.

PLASTIC

The recycling of plastic provides a sustainable source of raw materials for industry. Recycling it also significantly reduces environmental problems, since plastic is not a biodegradable materialRecycling also reduces energy consumption and reduces CO2 emissions, thus limiting contamination and climate change. There are many different types of plastic, so to recycle it correctly it is essential than it be taken to

clean points where it can be identified and separated according to the various types.

TEXTIL

The use of textile waste is essential when we talk about recycling. Recycling it helps to reduce water consumption and the release of gases from the production process. To dispose of textile waste appro-

priately it should be taken to a centre for specialised waste, where they can separate the individual textile fibres.

IMPORTANT: follow these recommendations to recycle the products correctly. Remember that recycling is more than just an action, it is a responsibility to preserve natural resources.

Page 27: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

25

The Saxun bioclimatic pergola is composed of a waterproof structure with adjustable aluminium slats, driven by a motor.

Its main structure is made of 6063 T5 alloy aluminium profiles, lacquered or anodised according to the techni-cal specifications of the Qualicoat and Qualanod quality brands. This structure is totally self-supporting and can be dismantled, so that no type of work or construction is required for its installation.

Our pergolas, just like the rest of our products, are subjected to a variety of tests in our labs in order to check their resistance and behaviour in every type of circumstance.

Tests carried out following the requirements of international standards, involving parameters such as wind re-sistance and loads of rain or snow, demonstrate the excellent performance of our bioclimatic pergolas against the most adverse conditions.

The P-150 and P-190 pergolas were tested in accordance with the following standards, obtaining the following results;

WIND RESISTANCE:

P-150 and P-190 Standard: EN 13659CLASS 6 (Approx. 112 km/h)Tested up to 190 km/h, without breakage due to limitation of the test bench.

RAIN LOAD:

P-150 and P-190 Standard: EN 12056-3Classification: (0.03 l/s max.) constant torrential rain approx. 108 l.m2/h (struc-ture + slat)

SNOW LOAD:

P-150Standard: EN 1999 Eurocode 9Aluminium structures projects.

≤65 kg/m²(Including own weight)

P-190Standard: EN 1999 Eurocode 9Aluminium structures projects.

≤100 kg/m²(Including own weight)

ANNEX B

CERTIFICATE OF GUARANTEE

Page 28: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

BIOCLIMATIC PERGOLA

MAXIMUM DIMENSIONS:

P-150 5.000 mm x 3.600 mm x 3.000 mm* Approximate weight of 310 Kg

P-190 6.200 mm x 4.200 mm x 3.000 mm* Approximate weight of 485 Kg

* Length (mm) X Width (mm) X Height (mm)

FINISHING WARRANTY:Giménez Ganga, S.L.U declares that all its extruded and surface treated aluminium profiles, which form part of the Bioclimatic Pergolas product range, are manufactured at least under Qualanod specifications in anodised finishes and Qualicoat in the case of lacquered finishes.

The guarantee of these finishes extends over a period of 10 years, provided that the quality of the finish is cho-sen correctly according to the location of the installation and that the corresponding maintenance indicated in the manual of the pergolas is carried out.

BRUSH GUARANTEE:The brushes offer a 10-year guarantee from the date of manufacture in case the product does not meet the re-quired standards. It will be replaced free of charge during the guarantee period excluding those cases in which the product is modified, used incorrectly or damaged, as well as for any other improper handling by the user during its installation or replacement.

MOTOR GUARANTEE:A 2-year guarantee is offered for motors, just as for the pergola seals. In the terms of the guarantee, faults caused by incorrect installation and/or use of the products, tampering, electrical variations, as well as by for-tuitous causes or natural disasters considered to be of a special nature are excluded.

ELECTRICAL AND/OR ELECTRONIC DEVICE GUARANTEE:The guarantee applicable to electrical and electronic devices is for 2 years, as established in the current leg-islation. The repair or replacement of defective parts is guaranteed, as long as they have not been caused by wear, breakage, faulty installation, incorrect use, dirt, negligence or accident.

Page 29: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

ASSEMBLY INSTRUCTIONS 4 DUPLEX COLUMNS P-190

27

CLIENT: ORDER/QUOTE:

Prior to placement of columns OKSquaring and parallel alignment of bases for anchoring to floor slab

Strength of attachment of bases for anchoring to floor slab

Accurate levelling of bases for anchoring to floor slab

Prior to installation of slats OKStrength of wall fasteners

Confirm accurate plumbing of columns

Confirm accurate levelling of beams

Prior to final installation of motor OKConfirm wires are correctly earthed in compliance with REBT

Visual inspection of electrical installation, loose cables, pipes, stuffing boxes, closing and sealing

of boxes (motor cable)

Confirm correct insertion of all security screws (attachment of slat axes)

Confirm correct clipping of collectors and slat axes

Confirm correct functioning, (smooth and silent) when opening and closing manually, (before

installing the motor)

Confirm proper sealing by applying water to critical points with a hose or bucket

Check tightness of all screws according to tightening chart, (except the transmission)

During final installation of motor OKConfirm correct operation of all motor manoeuvres, according to the issuer

Re-check and confirm that the drainage collectors, channels and conduits are clean and free of

anything that might hinder proper drainage

Check profiles and slats are clean (use pH-neutral soap and dilute heavily)

Check functioning of optional extras OKLED lighting at all levels

Music, Bluetooth and loudspeaker equipment

Infra-red heating

Rain sensor

Temperature sensor

WARNINGS• The structural stability of the pergola cannot be guaranteed if any foreign parts are attached to it.• The proper evacuation of rainwater cannot be guaranteed if you fail to enable the channels and downspouts recommended in the quotation.

Installer comments

Date, signature and stamp of installer I confirm receipt of the installed pergola, with no observ-able defects. I have received and understood the instruc-tions for use and maintenance, and the warranty condi-tions.

Signed by the client

Page 30: 4 DUPLEX COLUMNS P-190...1 Unscrew the ULS (ISO 7380) A2 M6x16 screws from the “U” profile motor support (A). 2 Insert the tip of the motor piston rod into the transmission plate

MK

0572

• IN

G •

01

• 02

19

saxun.com