3WL12 3WL1 air circuit breakers - Portfolio overview Frame size 0 Frame size I Frame size II Frame size III Type 3WL10 3WL11 3WL12 3WL13 Rated voltage up to 690 V up to 1,000 V up to 1,150 V up to 1,150 V Rated current 630 A I 800 A I 1,000 A I 1,250 A 630 A I 800 A I 1,000 A I 1,250 A I 1,600 A I 2,000 A 800 A I 1000 A I 1,250 A I 1,600 A I 2,000 A I 2,500 A I 3,200 A I 4,000 A 4,000 A I 5,000 A I 6,300 A Mounting I Number of poles Withdrawable I 3-/4-pole Fixed-mounted I 3-/4-pole Withdrawable I 3-/4-pole Fixed-mounted I 3-/4-pole Withdrawable I 3-/4-pole Fixed-mounted I 3-/4-pole Withdrawable I 3-/4-pole Fixed-mounted I 3-/4-pole Dimensions in mm width height depth width height depth width height depth width height depth width height depth width height depth width height depth width height depth 278 I 348 363,5 271 210 I 280 296 183 320 I 410 468 I 518 471 320 I 410 462 357 460 I 590 468 I 518 471 460 I 590 462 357 704 I 914 468 I 518 471 704 I 914 462 357 Breaking capacity I cu = I cs (440 V AC or 500 V AC) 440 V AC 42 kA I 55 kA I 66 kA 500 V AC 55 kA I 66 kA I 85 kA 500 V AC 66 kA I 85 kA I 100 kA I 130 kA 500 V AC 100 kA / 150 kA (130 kA, 4 pole) Breaking capacity I cu = I cs (690 V AC) up to 50 kA up to 85 kA up to 100 kA up to 150 kA (130 kA, 4 pole) Endurance (Operating cycles) • Mechanical maintenance • Electrical maintenance up to 20,000 up to 8,000 up to 25,000 up to 25,000 up to 17,500 up to 17,500 up to 10,000 up to 10,000 UL variants available Direct communication connectivity ¹ ) Modbus TCP, Modbus RTU, PROFIBUS, PROFINET Modbus TCP, Modbus RTU, PROFIBUS, PROFINET Modbus TCP, Modbus RTU, PROFIBUS, PROFINET Modbus TCP, Modbus RTU, PROFIBUS, PROFINET Optional integrated metering function ¹ ) yes (incl. internal voltage tap) yes (incl. internal voltage tap) yes (incl. internal voltage tap) yes (incl. internal voltage tap) Comprehensive CAx Data and TIP Support (easy engineering) 3WL10 - Electronic trip units 3WL11 / 12 / 13 - Electronic trip units Basic protection function ETU320 ETU350 ETU360 ETU650 ETU660 ETU15B ETU25B ETU27B ETU45B ETU45B ETU76B L Overload protection (long-time delay) S Short-circuit protection (short-time delayed) I Short-circuit protection (instantaneous) N Neutral conductor protection optional optional G Ground fault protection optional optional optional LCD display Direct communication connectivity optional optional optional optional optional Measurement function optional optional optional optional optional Action item siemens.com/quickselect-3wl10 siemens.com/quickselect-3wl11 siemens.com/quickselect-3wl12 siemens.com/quickselect-3wl13 1) depending on the ETU (Overcurrent release (electronic trip unit) integrated Versatile and with communication capability 3WL air circuit breakers offer highly flexible application and consistent communication capability. They ideally fulfill the increased requirements for air circuit breakers, particularly with regard to the operation and monitoring of network events when using electronic control systems. The quality of this series is setting standards around the world. Reliable, versatile and perfectly integrated You need more information about 3WL air circuit breakers? Then feel free to take advantage of our comprehensive support. From planning to commissioning to operation, we’re happy to help you at any time. siemens.com/3WL Information Planning/ Ordering Operation/ Service Training

Transcript of 3WL1 air circuit breakers - Portfolio overview versatile...

  • 3WL12

    3WL1 air circuit breakers - Portfolio overview

    Frame size 0 Frame size I Frame size II Frame size III

    Type 3WL10 3WL11 3WL12 3WL13

    Rated voltage up to 690 V up to 1,000 V up to 1,150 V up to 1,150 V

    Rated current 630 A I 800 A I 1,000 A I 1,250 A 630 A I 800 A I 1,000 A I 1,250 A I 1,600 A I 2,000 A 800 A I 1000 A I 1,250 A I 1,600 A I 2,000 A I 2,500 A I 3,200 A I 4,000 A 4,000 A I 5,000 A I 6,300 A

    Mounting I Number of poles Withdrawable I 3-/4-pole Fixed-mounted I 3-/4-pole Withdrawable I 3-/4-pole Fixed-mounted I 3-/4-pole Withdrawable I 3-/4-pole Fixed-mounted I 3-/4-pole Withdrawable I 3-/4-pole Fixed-mounted I 3-/4-pole

    Dimensions in mmwidth height depth width height depth width height depth width height depth width height depth width height depth width height depth width height depth

    278 I 348 363,5 271 210 I 280 296 183 320 I 410 468 I 518 471 320 I 410 462 357 460 I 590 468 I 518 471 460 I 590 462 357 704 I 914 468 I 518 471 704 I 914 462 357

    Breaking capacity Icu = Ics (440 V AC or 500 V AC)440 V AC

    42 kA I 55 kA I 66 kA500 V AC

    55 kA I 66 kA I 85 kA500 V AC

    66 kA I 85 kA I 100 kA I 130 kA500 V AC

    100 kA / 150 kA (130 kA, 4 pole)

    Breaking capacity Icu = Ics (690 V AC) up to 50 kA up to 85 kA up to 100 kA up to 150 kA (130 kA, 4 pole)

    Endurance (Operating cycles) • Mechanical maintenance • Electrical maintenance

    up to 20,000up to 8,000

    up to 25,000up to 25,000

    up to 17,500up to 17,500

    up to 10,000up to 10,000

    UL variants available – ✓ ✓ ✓

    Direct communication connectivity ¹) Modbus TCP, Modbus RTU, PROFIBUS, PROFINET Modbus TCP, Modbus RTU, PROFIBUS, PROFINET Modbus TCP, Modbus RTU, PROFIBUS, PROFINET Modbus TCP, Modbus RTU, PROFIBUS, PROFINET

    Optional integrated metering function ¹) yes (incl. internal voltage tap) yes (incl. internal voltage tap) yes (incl. internal voltage tap) yes (incl. internal voltage tap)

    Comprehensive CAx Data and TIP Support (easy engineering)

    ✓ ✓ ✓ ✓

    3WL10 - Electronic trip units 3WL11 / 12 / 13 - Electronic trip units

    Basic protection function ETU320 ETU350 ETU360 ETU650 ETU660 ETU15B ETU25B ETU27B ETU45B ETU45B ETU76B

    L Overload protection (long-time delay) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓

    S Short-circuit protection (short-time delayed) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓

    I Short-circuit protection (instantaneous) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓

    N Neutral conductor protection ✓ ✓ ✓ ✓ ✓ ✓ optional optional ✓

    G Ground fault protection ✓ ✓ ✓ optional optional optional

    LCD display ✓ ✓ ✓ ✓

    Direct communication connectivity optional optional optional optional optional

    Measurement function optional optional optional optional optional

    Action item siemens.com/quickselect-3wl10 siemens.com/quickselect-3wl11 siemens.com/quickselect-3wl12 siemens.com/quickselect-3wl13

    1) depending on the ETU (Overcurrent release (electronic trip unit) ✓ integrated

    Versatile and with communication capability3WL air circuit breakers offer highly flexible application and consistent communication capability. They ideally fulfill the increased requirements for air circuit breakers, particularly with regard to the operation and monitoring of network events when using electronic control systems. The quality of this series is setting standards around the world.

    Reliable, versatile and perfectly integrated

    You need more information about 3WL air circuit breakers?Then feel free to take advantage of our comprehensive support. From planning to commissioning to operation, we’re happy to help you at any time.

    siemens.com/3WL

    Information Planning/Ordering

    Operation/Service

    Training

    http://siemens.com/quickselect-3wl10http://siemens.com/quickselect-3wl11http://siemens.com/quickselect-3wl12http://siemens.com/quickselect-3wl13http://siemens.com/3WL

  • Published by Siemens AG 2019 Energy Management Division Siemensstraße 10 93055 Regensburg Germany

    Article No. EMLP-B10184-00-7600 3WL air circuit breakers – Quick Selection Guide

    Printed in Germany Dispo 25600 • BR 08172.0

    Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract.

    siemens.com/3WL

    3WL air circuit breakersQuick Selection Guide

    Applications

    3WL – Highlights

    Power monitoring Commissioning /parameterization

    with COM15, COM16with COM060with COM35

    with COM040, COM042with COM041, COM043

    PROFIBUS / Modbus RTU

    PROFINET /Modbus TCP

    powerconfigpowermanager

    3VA-line

    3VA 3VA 3VA 3WL103VA273WL11 - 3WL13

    3VA-lineCubicleBUS

    I201_19702

    COM800 COM100

    DSP800

    PAC3200PAC4200

    Communication landscape

    3WL11-13 – Mechanical Upgrades

    Frame size 1-3

    + Increased short circuit performance(Icu

    , Icw

    , Ics

    )

    + Longer endurance and lifecycle(up to 25,000 cycles)

    + Increased operating temperature range -25°C -40°C3WL11-13 – COM35

    ■ PROFINET IO & Modbus TCP ■ PNO certificated ■ Switched Ethernet ■ Highest performance (CC-C)

    3WL11-13 – Metering function with internal voltage tap

    ■ On the lower connection ■ On the upper connection

    3WL & 3VA – Low voltage circuit breaker system3

    VA

    1 (

    IEC

    ) TM

    TU

    Curre

    nt Lim

    iting

    100 A 160 A 250 A 400 A 630 A 1,000 A

    3V

    A2

    (IE

    C)

    ETU

    100 A 160 A 250 A 400 A 630 A 1,000 A 1,600 A

    MCCB Platform MCCB-ACB Platform ACB Platform

    3W

    L (I

    EC

    ) E

    TU

    Frame size 0 Frame size 1 Frame size 2 Frame size 3

    Cu

    rren

    t With

    stand = identical housing dimensions

    1,250 A 2,000 A 4,000 A 6,300 A

    NEW N

    EU

    up to

    +25

    %

    up to

    +30

    %

    http://siemens.com/3WL