3496 SDMO RP 60HzGB 215 - Kraft Power · 60HZ 15KVA - 2200KVA SDMO ®, Rental Power The Rental...
Transcript of 3496 SDMO RP 60HzGB 215 - Kraft Power · 60HZ 15KVA - 2200KVA SDMO ®, Rental Power The Rental...
E N G L I S H
RPW60/GB-2005/1 Global PowerSolutions
RENTAL POWER
60HZ15KVA - 2200KVA
60HZ15KVA - 2200KVA SDMO®, the generating set s
Since i ts c reat ion in 1966, SDMO ®
Industr ies has chosen to spec ia l ize
exclus ive ly in generat ing sets,
so as to concentrate on the competitiveness
and quality of its services. From this
specialization, SDMO® has acquired skills
recognized by a l l o f i t s customers.
SDMO® is now one of the world’s leading
companies in the generating set market
and i s committed to supply ing you
with impeccable products.
Spec ia l iz ing in the manufacture of
generating sets, SDMO® offers you a wide
range of standard sets, from 7.5 to 2,200
kVA. Its teams, spread over 3 production
sites, have skills at the leading edge
of the new technol og ies and of
manufacturing processes. Each team works
on a common data base, and specializes in
a range of standard products, thus
increasing its efficiency. SDMO® undertakes
to supply you with a reliable, innovative
and quality electrical energy source,
to accompany you in each of your projects.
HANDINESS x HANDLING2 PERFORMANCE SAFETY
he generating set specialist
Now SDMO® is represented in over 150
countries, thought a network of agents,
distributors, 8 subsidiaries all established
in Great Britain, Spain, Belgium, Singapore,
Argentina, the United States, Brazil, Nigeria
and a liaison office in Algeria. SDMO®
devotes its energy to accompanying you in
the successful completion of each of your
projects all over the world.
In order to provide you with proof of
reliability, SDMO® has introduced a quality
procedure. Its careful compliance with this
commitment has made it possible to obtain
ISO 9001 certification. For you this is the
guarantee that delivery will take place on
time, with the best possible monitoring of
your order. The reputation for service quality
acquired by SDMO® all over the world is
the result of this continuous search for
improvement.
SDMO® is committed to supplying you
with the energy source which suits you,
where you need it
MAINTENANCEGlobal PowerSolutions 3
60HZ15KVA - 2200KVA SDMO®, Rental Power
The Rental Power range combines
the qualities, reliability and versatility
of these devices with an appropriate
service policy.
In phase with the expectations and
constraints of the rental and construction
industry, the Rental Power range
accurately and appropriately meets
the expectations of professionals.
Ranging from 15 to 500 kVA, with
sound-proof hoods that can be fitted
onto road trailers, or in containers up
to 2,200 kVA, or even the "EVENT"
ultra-silent concept (available from
60 to 275 kVA), these generator sets
have been designed to combine all of
the properties essential for this specific
market: compactness, low noise levels,
ease of use, reliability and safety.
Discover the innovative products in the
RENTAL POWER range and ensure
yourself the best possible return on
investment.
Handiness and compactness were the main criteria behind the choices made by the
technical teams at each step in the design process.
HANDINESS x HANDLING PERFORMANCE
In accordance with the demands of
the construction and rental market,
the Rental Power range achieves the
highest performance levels.
Alternator with AREP
voltage regulator
(improvement of
the electrical starting
engines capacities)
Central single-pointlifting eye Heavy duty skid
with provisions for winching
Forklift pockets
HANDINESS x HANDLING4 PERFORMANCE SAFETY
MAINTENANCE
Each part has been designed in order to optimise speed of
implementation and ease of maintenance.
er range +
SAFETY
Safety for both humans and equipment is
a top priority constant.
Double wall frame
with retention
tank for fluids
Air filter with replacable cartridge Radiator with cleaning access
Emergency
stop button
Connection
terminals
Sound attenuated
enclosure
MAINTENANCEGlobal PowerSolutions 5
SDMO ® REFERENCES R20UC R25UC R35UC R50UC R75UC R120UC
GensetPrime Power (kVA) 480V 18 26 38 49 74 120Prime Power cos phi=0.8 (kW) 480V 14 21 30 39 59 96Standby Power (kVA) 480V 20 29 41 54 81 132Standby Power (kW cos phi=0.8) 480V 16 23 33 43 65 106Frequency 60 60 60 60 60 60Genset RPM 1800 1800 1800 1800 1800 1800Available voltages, single-phase 110, 127, 139, 240, 254, 277 V SwitchableAvailable voltages, three-phase 208, 220, 240, 415, 440, 480 V SwitchableCanopy model M127 M127 M127 M128 M128 M129Noise level (dBA) @ 7 meters, 23 ft 62,7 66,7 67,5 66 66 69,6Alternator / 60HzMake Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy SomerModel LSA 422S4 LSA 422S5 LSA 422L9 LSA 432S3 LSA 432L6 LSA 442S7Prime Power (kVA) 480V 22 26 38 56 77 150Prime Power (kW cos phi=0.8) 480V 18 21 30 45 62 120Standby Power (kVA) 480V 24 29 42 62 85 165Standby Standby Power (kW cos phi=0.8) 480V 19 23 34 50 68 132Insulation Class H H H H H HVoltage adjustment potentiometer Yes Yes Yes Yes Yes YesAutomatic voltage regulator +/- 1.5% +/- 1.5% +/- 1.5% +/- 1.5% +/- 1.5% +/- 1.5%Motor starting capability (kVA) 64 65 94 150 215 330PF=0.6 rotor blocked @ 35% Dip voltageEngine / 1800rpmMake Mitsubishi Mitsubishi Mitsubishi John Deere John Deere John DeereModel S4L2-Y262SD S4Q2-Y262SD S4S-Y262SD 4045DF270 4045TF270 4045HF275Prime Power (kW) 16,4 23,7 33,5 44 65 104Prime Power (BHP) 22 32 45 59 87 139Type In line In line In line In line In line In lineNumber of cylinders 4 4 4 4 4 4Auxiliaries voltage 12 12 12 12 12 12Speed regulation +/- 2.5 +/- 2.5 +/- 2.5 +/- 2.5 +/- 2.5 +/- 0.5Cool start capability (°C) -20 -20 -20 -18 -18 -18Displacement 1,75 2,5 3,33 4.48 4.48 4.48Bore 78 88 94 106 106 106Stroke 92 103 120 127 127 127Fuel / Cooling Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / WaterOil Capacity (Gal) 1,43 1,72 2,38 3,57 3,57 3,57Cooling system capacity (Gal) 1,29 2,14 2,35 4,99 6,24 5,34FuelGreat autonomy fuel tank capacity (Gal) 60,8 60,8 60,8 103 103 133,4Full load fuel consumption (Gal/Hour) 1,29 1,96 2,59 3,25 4,57 6,10Run time (hours)at 100% load 42,2 28,0 21,1 28,5 20,3 19,7at 75% load 54,5 37,0 25,2 35,8 26,0 25,7at 50% load 69,0 50,5 34,5 50,1 36,9 33,2at 25% load 123,2 90,2 61,6 89,5 66,0 59,2Dimensions M127 M128 M129Overall lenght (in) 85 85 85 92,3 92,3 102,4Overall width (in) 38 38 38 41,7 41,7 45,3Overall height (in) 62,3 62,3 62,3 70,5 70,5 70,3Wet weight (lbs) 2580 2668 2911 4359 4558 5632Dry weight (lbs) 2117 2205 2426 3499 3698 4518Control panelSDMO Control panel Type NEXYS NEXYS NEXYS NEXYS NEXYS NEXYS
60HZ15KVA - 2200KVA Specifications
CA
PO
TAJE
22
6*
HANDINESS x HANDLING6 PERFORMANCE SAFETY
R145UC R190UC R260UC R325UC R460UC R600UC
145 193 262 327 456 573116 154 210 262 365 458160 212 288 360 502 630128 170 230 288 402 50460 60 60 60 60 60
1800 1800 1800 1800 1800 1800/
208,220,240,416,440,480V ReconnectableM226 M226 M227 M227 M228 M229
64 68,9 70,4 71,3 74,1 75
Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy SomerLSA 442S7 LSA 442L12 LSA 462L6 LSA 462VL12 LSA472VS3 LSA 472M7
150 206 300 381 570 625120 165 240 305 456 500165 227 330 419 550 688132 182 264 335 440 550
H H H H H HYes Yes Yes Yes Yes Yes
+/- 1.5% +/- 1.5% +/- 1.5% +/- 1.5% +/- 1.5% +/- 1.5%
330 420 650 1180 1230 1800
John Deere John Deere John Deere John Deere Volvo Volvo4045HF475 6068HF275-187 6081HF070-260 6081HF070-318 TAD1242GE TAD1641GE
126 165 226 279 391 485169 221 303 374 524 650
In line In line In line In line In line In line4 6 6 6 6 6
12 12 12 12 24 24+/- 0.5 +/- 0.5 +/- 0.5 +/- 0.5 +/- 0.5 +/- 0.5
-18 -18 -18 -18 -30 -304.48 6.72 8,1 8,1 12,1 16,1106 106 116 116 131 144127 127 129 129 150 165
er Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / Water Diesel / Water5,68 8,32 8,45 8,45 9,25 12,686,08 6,82 10,3 10,3 11,62 15,85
22,3 229,3 251 251 361,4 467,68,43 10,91 14,03 16,80 24,49 31,89
24,5 18,9 16,1 13,4 13,3 13,232,3 24,9 21,3 18,0 18,2 18,047,3 36,3 30,4 26,1 27,1 26,684,5 64,9 54,3 46,5 48,3 47,6
M226 M227 M228 M229140,2 140,2 159,7 159,7 178,2 200,147,2 47,2 54,3 54,3 55,5 61,480,5 80,5 95,9 95,9 109,4 106,57389 7852 10247 10644 13750 160745442 5905 8108 8527 10734 12458
NEXYS NEXYS NEXYS TELYS TELYS TELYS
CA
PO
TAJE
12
9*
CA
PO
TAJE
12
7*
* N
on
co
ntr
act
ua
l p
ictu
re –
se
e o
pti
on
s list
.
CA
PO
TAJE
22
8*
CA
PO
TAJE
22
9*
CA
PO
TAJE
22
7*
CA
PO
TAJE
12
8*
MAINTENANCEGlobal PowerSolutions 7
SDMO ® REFERENCE R20UC R25UC
Sound Attenuated Enclosure M127 M127
Leroy Somer Alternator l l
AREP excitation l l
Voltage regulation at +/- 1.5% l l
Alternator with vacuum impregnation l l
Radiator with easy cleaning access l l
Central single-point lifting eye l l
Nexys Control Panel l l
Telys Control Panel O O
3-pole circuit breaker l l
Switchable voltage (3 phase - 120/208V - 277/480V, 1 phase - 120/240V) l l
Reconnectable voltage (120/208V - 277/480V) 5 5
Rental Power range color / White l l
Automatic predisposition l l
HI 01 1 Tank - Heavy duty skid with provisions for dragging or slinging- Large fuel tank- Forklift pockets* l l
- 110% Containment for oil, coolant and fuel spills- Quick-drain device
HI 03 Roof access ladder 5 5
HI 04 Protection Devices- Air inlet preheating starting aid- Voltage adjustment potentiometer l l
- Speed adjustment potentiometer (electronic governor only) Oil drainage pump
HI 05 2 Main bus connection studs l l
HI 06 3 Water/Fuel separator l l
HI 07 4 Hot parts safety protection O O
HI 10 5 Battery disconnect switch l l
HI 11 Oil drainage pump O O
HI 26 Heavy duty two stage air filter l l
HI 24 6 3 way fuel valve O O
HI 25 Electronic governor 5 O
HI 28 2 Receptacles with individual breakers l l
HI 29 Special color (3 weeks extra lead time) O O
HI 30 Road trailer O O
HI 31 Automatic starting pack for Telys O O
HI 32 Explosive atmosphere kit 5 5
HI 33-A Dual frequency NC NCHI 34 Tropical impregnation (T26S002) O O
HI 37 Block heater 120V O O
60HZ15KVA - 2200KVA Base and Options
1
2
*Except M227, M228, M229
l Standard feature
O Optional equipment
5 Non available Option
NC Please contact us
HANDINESS x HANDLING8 PERFORMANCE SAFETY
R35UC R50UC R75UC R120UC R145UC R190UC R260UC R325UC R460UC R600UC
M127 M128 M128 M129 M226 M226 M227 M227 M228 M229l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l 5 5
O O O O O O O O l l
l l l l l l l l l l
l l l l l l 5 5 5 5
5 5 5 5 5 5 l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
5 5 5 5 5 5 l l l l
l l l l l l l l l l
l l l l l l l l l l
l l l l l l l l l l
O O O O O O O O O O
l l l l l l l l l l
O O O O O l l l l l
l l l l l l l l l l
O O O O O O O O O O
O O O l l l l l l l
l l l l l l 5 5 5 5
O O O O O O O O O O
O O O O O O O O O O
O O O O O O O O O O
5 O O O O O O O O O
NC NC NC NC NC NC NC NC NC NCO O O O O O O O O O
O O O O O O O O O O
3 5 64
MAINTENANCEGlobal PowerSolutions 9
60HZ15KVA - 2200KVA Contenergy
From 650 to 2,200 kVA, SDMO®
offers you a high degree of flexibility
with the CONTERNERGY concept.
These compact models are offered in
versions specifically adapted to
mobile rental applications thanks, in
particular, to a low noise level and
great adaptation flexibility
CIR 20 SSI
HANDINESS x HANDLING10 PERFORMANCE SAFETY
l Standard feature
5 Non available option
EN 01 Option code
FD 01 Free Option
Ba
seF
ue
lPa
nel
sD
imen
sions
Sp
ecifi
catio
ns
ISO 20 CIR 20 SSI EUR 40 SIEUR 40 SSI
Base girder l l l
Starter, charging alternator 24V l l l
Batteries with electrolyte SO001 SO001 SO001Standard air-filter l l l
Lub oil drain pump l l l
Sound-proofing type SI SSI SI/SSIHigly efficient silencer built in-attenuation 30dB(A)
l l l
Floor Wood Waterlight Steel Wood
Number of doors 1 2 2Air outlet galvanized steel rain guard grid
CT 005 l l
Emergency light and emergency fuel valve
CT 007 CT 007 CT 007
Exhaust exit on flanges CT 011 CT 011 CT 011White paint finishing (RAL 9010) l l l
Catch pit under the whole of the container
CT 014 CT 014 CT 014
Tank without retention bund 500L l l 5
Tank with retention bund 500L 5 5 l
Tank with retention Bund 2000L + client connection terminal strip
5 CT 003 5
Auto. fuel fill kit (1 pump 1m3/H°) CT 008 CT 008 CT 008Auto. fuel fill kit (2 pumps 1m3/H) 5 5 CT 009Auto. fuel fill kit (2 pumps 4m3/H) 5 5 CT 010Electric panel EC compliance l l l
Panel Mics TELYS CM 40 CM 40 CM 40Panel Mics KERYS CA 600 CA 600 CA 600Length (mm) 6058 6058 12192Width (mm) 2438 2438 2438Height (mm) 2896 2896 2896
Me
sure
sO
pe
rati
on
Op
era
tio
n a
nd
/o
r sa
fety
ligh
tsE
ng
ine
pa
ram
ete
rs
Sa
fety
de
vice
sM
isce
lla
ne
ou
sA
uto
ma
tio
n
NEXYS TELYS
Line voltages in Volts l LCD l LCDSingle voltages in Volts l LCD l LCDPhase currents in Amps l LCD l LCDNeutral current in Amps 5 l LCDFrequency in Hertz l LCD l LCDAll generating set states,all starter phases
l LCD l LCD
Analogical indicator OP, WT, BV, FL l l
Ammeter battery 5 O
Indication of engine speed l LCD l LCDIndication of battery voltage l LCD l LCDElapsed hour meter l LCD l LCDPowering up 5 l
Fuel solenoid-operated valve control l l
Starter control l l
Plug preheating control O O
Water preheating control O O
Mains contactor control 5 O
Generating set contactor control 5 O
Oil pressure fault l l
Water temperature fault l l
Fail to start fault l l
Overspeed fault l l
Set ready for load l l
Charging alternator fault l l
General alarm l l
General fault l l
Panel lamp, 22 dia. l l
STOP/MANU/AUTO/TEST mode 5 l
Generating set side contactor closed
5 O
Mains side contactor closed 5 O
Any faults or any alarms messages 5 l LCD
NEXYS TELYS
Oil pressure fault l l
Water temperature fault l l
Emergency stop fault l l
Overload or short-circuit alarmor fault
O l (1)
Min/max battery voltage alarm or fault
5 l (1)
Min/max alternator voltage alarmor fault
5 l (1)
Min/max alternator frequency alarm or fault
5 l (1)
Overspeed fault l l
Differential relay present fault l l (2)
Differential triggering alarm or fault
O O (1+2)
Automatic standby l l
Automatic extinction 5 l
4 modes 5 l
Engine stopping for coolingen auto 5 l
Voltage and speed stabilization l l
Plug preheating l l
ATS changeover presence choice 5 O
Mains contactor position return 5 (self-controlled INS) O
Generating set and mains contactor position return
5 (self-controlled INS) O
Generating set contactor manual closing
5 O
Generating set contactor manual opening
5 O
Starting on clock 5 O
External starting order l l
Mains sensing 3-ph O O (3)
Test LEDs l l
Fault reset l l
External AMF predisposition O O
3-phase with or without neutral, 2-phase or single-phase use
l (5) l (4)
12V battery charger O O
Differential protection with time and sensitivity adjustment
l (std > R66K) (1) l (std > R66K) (6)
Alarm hooter O O
NEXYS/TELYS
KERYSFor generator sets intended for coupling applications, the Kerys
monitoring and control box is a user-friendly and intuitive tool
offering a very broad range of features.
(1) The choice Alarm or Fault is programmed through the keyboard. (2) The earth fault protection is ensured by one external module connected to the CB12 card and through connecting of one tiny relay on theCB12 card. A local configuration is also needed. (3) MICS DS mains detection is proposed as a base in the source inverter. In the case whereby the source inverter is not chosen, the MICS DS module can be mouldedin the panel. (4) Choice is revised through programming - The alternator’s voltage reference connecting wire modification is necessary. (5) The earth fault protection is ensured by one external module.
l Standard
O Option code
l LCD Standard with LCD message
Command control panel
MAINTENANCEGlobal PowerSolutions 11
ISO 9001
SDMO Industries
Sites in France
Rental Power also means:
The Event range: based on the same design as the generator sets of the
Rental Power range, the Event concept allows us to offer equipment
with the same advantages, but with even lower noise levels. For all
circumstances demanding perfect noise discretion (shows, work in urban
areas, etc.); the noise levels of the generator sets of this design do not
exceed 70 dBA at a distance of 1m.
Lighting masts: products directly derived from
the generator sets. A light source associated
with a power generation auxiliary for all types
of work site.
For more details, please contact us.
SUBSIDIARIES
SDMO GENERATING SETS Inc
USA
Tel. +1 305 863 00 12 – Fax +1 305 863 97 81
SDMO DO BRASIL Ltda
Brazil
Tel. +55 (11) 4053-2700 – Fax +55 (11) 4053-2718
SDMO ARGENTINA
Argentina
Tel./Fax +54 114 205 3005
SDMO ASIA PACIFIC PTE Ltd
Singapore
Tel. +65 6419 3788 – Fax +65 6419 3798
SDMO ENERGY Ltd
UK
Tel. +44 (0) 1932 345 777 – Fax +44 (0) 1932 350 033
SDMO INDUSTRIES IBERICA
Spain
Tel. +34 90 230 56 56 – Fax +34 93 580 31 36
SDMO NV/SA
Belgium
Tel. +32 3 646 04 15 – Fax +32 3 646 06 25
SDMO LAGOS
Nigeria
Tel. +234 (0) 1 776 95 95 – Fax +234 (0) 1 461 34 75
OFFICE
SDMO ALGER
Algeria
Tel. +213 21 92 55 84 – Fax +213 21 92 47 76
- 0
6/
20
05
– G
B –
50
/0
1 –
SD
MO
– R
CS
Bre
st 5
48
20
2 9
85
– P
ho
tos
: St
ud
io 2
9,
Gu
illa
um
e T
ea
m –
Pri
nte
r :
Ca
llig
rap
hy
(Re
nn
es)
– A
ll in
ord
er
to im
pro
ve s
till
fu
rth
er
the
qu
ality
of
its
pro
du
cts,
SD
MO
In
du
stri
es
rese
rve
s th
e r
igh
t to
mo
dif
y a
ny
of
the
sp
eci
fica
tio
ns
ind
ica
ted
in
th
is c
ata
log
ue
wit
ho
ut
pri
or
no
tice
. N
on
-co
ntr
act
ua
l d
ocu
me
nt.
Co
pyr
igh
t S
DM
O®.
Do
no
t d
isp
ose
of
the
hig
hw
ay.
Ca
talo
gu
e p
rice
giv
en
fo
r in
form
ati
on
: 1
.04
€
SDMO Industries – 12 bis rue de la Villeneuve – CS 92848 – 29228 BREST Cedex 2 – France
Tél. +33 (0)2 98 41 41 41 – Fax +33 (0)2 98 41 63 07 – Telex 615 092 F – http://www.sdmo.com