Heating, Ventilating, and Air-Conditioning
![Page 2: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/2.jpg)
TABLE OF CONTENTS• Types of Systems• Central Forced Air System
– Air Handling Unit• Hot Water System• Zoned Control System• Radiant Heat• Heat Pump• HVAC Plans
![Page 3: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/3.jpg)
Types of Systems
• Central Forced-Air Systems• Hot Water Systems• Zone Control Systems• Radiant Heat
![Page 4: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/4.jpg)
Central Forced Air System
• Most Common HVAC System• Circulates air through or around heating
and cooling devices.• A fan forces air into ducts• Supply ducts transport conditioned air into
building through diffusers or supply registers
• Air is routed back to heating/cooling device through return ducts
![Page 5: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/5.jpg)
Air Handling Unit (AHU)
• Device used to condition and circulate air as part of an HVAC system
• Large metal box containing a blower, heating or cooling elements, filter, and sound attenuators
• Connects to ductwork that distributes the conditioned air through the building and returns it to the AHU
Courtesy Eric Fisher
![Page 6: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/6.jpg)
Air Handling Unit (AHU)
• May need to supply heating, cooling, or both• A furnace generates heat
– Fuel oil or natural gas– Electric heating elements– Heat pump
• A refrigeration system absorbs heat– Air conditioner– Heat pump
![Page 7: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/7.jpg)
Air Handling Unit (AHU)• Smaller air handlers may contain a fuel-burning
heater or a refrigeration evaporator placed directly in the air stream
• Large commercial air handling units contain coils that circulate water– Boiler provides hot water or steam– Chiller provides chilled water
©iStockphoto.com ©iStockphoto.com
![Page 8: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/8.jpg)
Wikimedia
1. Supply duct2. Fan compartment3. Flexible connection4. Heating and/or cooling coil5. Filter compartment6. Return and fresh air duct
Typical AHU components:
Air Handling Unit (AHU)
![Page 9: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/9.jpg)
Hot Water System
• Water heated in boiler and circulated through pipes to radiators
• Requires plumbing rather than ductwork
©iStockphoto.com
![Page 10: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/10.jpg)
Zone Control System
• One heater and one thermostat per room• No ductwork• Often used in hotel rooms
![Page 11: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/11.jpg)
Radiant Heat• Supply heat directly to the floor, wall, or ceiling• Hot water pipes or electric heating element runs
through building component• Dependent on radiant heat
– Heat transferred from hot surface to people and objects
Wikimedia
![Page 12: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/12.jpg)
Heat Pump (HP)• A machine or device that moves heat from one
location (the source) to another location (the mechanical work)
• Can produce heating or cooling by reversing the direction of heat flow
• Can be used in:– Forced Air System– Hot Water System– Radiant Heat System
wikimedia
![Page 13: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/13.jpg)
HVAC Plans
Image Courtesy Novus Architects
![Page 14: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/14.jpg)
HVAC (Mechanical) Plans
Image Courtesy Novus Architects
![Page 15: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/15.jpg)
HVAC Mechanical Plans
Image Courtesy Novus Architects
![Page 16: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/16.jpg)
TABLE OF CONTENTS• Types of Systems• Central Forced Air System
– Air Handling Unit• Hot Water System• Zoned Control System• Radiant Heat• Heat Pump• HVAC Plans
![Page 17: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/17.jpg)
•en.wikimedia.org. Images retrieved Dec. 8, 2009.•Novus Architecture (formerly SGM Architects), Mt.
Pleasant, SC•www.istockphoto.com. Images retrieved Dec. 8, 2009.
Image Sources
![Page 18: 3.3 Hvac](https://reader031.fdocuments.us/reader031/viewer/2022030317/577ccf221a28ab9e788ef5c6/html5/thumbnails/18.jpg)
Heating, Ventilating, and Air-Conditioning