INSTALL GUIDE 33-00135EFS-09 ERM5220R Equipment Remote Module WITH REDLINK™ WIRELESS TECHNOLOGY Table of Contents About the ERM5220R 2 Installation Checklist 3 Terminal Designations 4 Installation 6 Checkout 12 Troubleshooting 13 Specifications 15 5 Year Warranty 17 CAUTION Read these installation instructions completely and follow them carefully. Installation must be performed by a qualified service technician and must comply with local codes. Disconnect power to all relevant devices before installing or servicing the ERM. Failure to connect the device according to these instructions may result in damage to the device, the controls, and/or personal injury.

Transcript of 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3....

Page 1: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

INSTALL GUIDE

33-00135EFS-09

ERM5220REquipment Remote ModuleWITH REDLINK™ WIRELESS TECHNOLOGY

Table of ContentsAbout the ERM5220R 2

Installation Checklist 3

Terminal Designations 4

Installation 6

Checkout 12

Troubleshooting 13

Specifications 15

5 Year Warranty 17

CAUTIONRead these installation instructions completely and follow them carefully.Installation must be performed by a qualified service technician and must comply with local codes.Disconnect power to all relevant devices before installing or servicing the ERM.Failure to connect the device according to these instructions may result in damage to the device, the controls, and/or personal injury.

33-00135EFS_E.book Page 1 Tuesday, February 18, 2020 3:52 PM

Page 2: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 2

About the ERM5220R

Fig. 1.

• Wireless RedLink™ communication between condensing unit/compressor or boiler and thermostat.

• Eliminates the need to run additional wires to your equipment, for example, during a heat pump upgrade.

• Suitable for outdoor use.• Temperature sensor terminals for outdoor temp sensors or indoor

freeze protection.• LEDs for easy installation checkout.• May reduce damage to homes since wiring/drilling is eliminated.

NOTE: The ERM5220R is compatible with updated models THX9421R5021, TH8321R1001, TH8320R1003, and TH8110R1008. THM5421R1021 EIM is also required with THX9421R5021. Optional with other models.

MCR35654

ERMWIRE

CONDENSINGUNIT

THERMOSTAT

ERM

BOILER

33-00135EFS_E.book Page 2 Tuesday, February 18, 2020 3:52 PM

Page 3: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

3 33-00135EFS—09

Installation ChecklistMATERIALS SUPPLIED:

• ERM5220R• Wall Anchors (x2) and Mounting Screws (x2)• Extra Cover Screw (optional)• Installation Instructions

TOOLS NEEDED (NOT SUPPLIED):

• Drill• Nut Driver Attachment for Drill• Wire Stripper• Small Flathead Screwdriver• Phillips Screwdriver• 120/240 V to 24 V Transformer (optional)

M35671

INSTALL GUIDE

33-00135EFS-03

ERM5220REquipment Remote ModuleWITH REDLINK™ WIRELESS TECHNOLOGY

Table of ContentsAbout the ERM5220R 2

Installation Checklist 3

Terminal Designations 4

Installation 6

Checkout 12

Troubleshooting 14

Specifications 16

5 Year Warranty 18

CAUTIONRead these installation instructions completely and follow them carefully.Installation must be performed by a qualified service technician and must comply with local codes.Disconnect power to all relevant devices before installing or servicing the ERM.Failure to connect the device according to these instructions may result in damage to the device, the controls, and/or personal injury.

M35669M35672

M35670

33-00135EFS_E.book Page 3 Tuesday, February 18, 2020 3:52 PM

Page 4: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 4

Terminal Designations

Fig. 2. Terminal Designations for Compressor.

M35

655

JRCYDLS1S1

TER

MIN

ALS

FO

R 1

0K O

HM

TE

MP

ER

ATU

RE

SE

NS

OR

. C

AN

BE

US

ED

TO

SE

NS

E O

UTD

OO

R T

EM

PE

RAT

UR

ES

WH

ICH

WIL

L B

E D

ISP

LAY

ED

O

N A

CO

MPA

TIB

LE R

edLI

NK

TH

ER

MO

STA

T.

CO

MP

RE

SS

OR

LIN

E F

AU

LT T

ER

MIN

AL.

FA

ULT

OC

CU

RR

EN

CE

WIL

L B

E C

OM

MU

NIC

ATE

D T

O C

OM

PATI

BLE

Red

LIN

K T

HE

RM

OS

TAT.

CO

MP

RE

SS

OR

DE

FRO

ST

TER

MIN

AL.

DE

FRO

ST

OC

CU

RR

EN

CE

WIL

L B

E C

OM

MU

NIC

ATE

D T

O C

OM

PATI

BLE

Red

LIN

K T

HE

RM

OS

TAT.

O/B

TE

RM

INA

L FO

R R

EV

ER

SIN

G V

ALV

E O

N H

EAT

PU

MP.

SE

CO

ND

STA

GE

OF

TWO

STA

GE

CO

MP

RE

SS

OR

.

FIR

ST

STA

GE

OF

TWO

STA

GE

CO

MP

RE

SS

OR

.

TER

MIN

ALS

FO

R 2

4VA

C P

OW

ER

.

TER

MIN

AL

FOR

JU

MP

ER

. JU

MP

ER

BE

TWE

EN

J A

ND

R S

HO

ULD

BE

IN P

LAC

E F

OR

CO

MP

RE

SS

OR

US

E.

THE

“D”

TER

MIN

AL

OP

ERAT

ES A

S A

N IN

PU

T FO

R D

EFR

OS

T. A

CTI

VE IN

PU

T O

N “

D”

TER

MIN

AL

WIL

L P

OW

ER A

UX1

. IF

“D”

TO A

UX1

IS N

OT

DES

IRED

, DO

NO

T C

ON

NEC

T “D

” TE

RM

INA

L TO

TH

E ER

M52

20R

. TH

IS F

EATU

RE

IS O

NLY

AC

TIVE

WH

EN T

HE

THE

ERM

5220

R IS

CO

NFI

GU

RED

FO

R U

SE

WIT

H A

CO

MP

RES

SO

R

TE

RM

INA

L D

ES

IGN

AT

ION

S F

OR

CO

MP

RE

SS

OR

O/BT

Y2T

1

1

33-00135EFS_E.book Page 4 Tuesday, February 18, 2020 3:52 PM

Page 5: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

5 33-00135EFS—09

Fig. 3. Terminal Designations for Boiler.

M35

656A

JRCYO/B

TDLS1S1

TER

MIN

ALS

FO

R 1

0K O

HM

TE

MP

ER

ATU

RE

SE

NS

OR

. C

AN

BE

US

ED

FO

R F

RE

EZ

E P

RO

TEC

TIO

N IN

TH

E C

AS

E O

F TH

E T

HE

RM

OS

TAT

LOS

ING

TH

E S

IGN

AL

TO T

HE

ER

M.

SE

NS

OR

MU

ST

RE

MA

IN IN

DO

OR

S T

O B

E U

SE

D F

OR

FR

EE

ZE

PR

OTE

CTI

ON

.

TER

MIN

AL

FOR

HE

AT C

ALL

.

TER

MIN

ALS

FO

R 2

4VA

C P

OW

ER

.

TER

MIN

AL

FOR

JU

MP

ER

. JU

MP

ER

BE

TWE

EN

J A

ND

R S

HO

ULD

BE

RE

MO

VE

D F

OR

BO

ILE

R U

SE

.

TE

RM

INA

L D

ES

IGN

AT

ION

S F

OR

BO

ILE

R

Y2T

TER

MIN

AL

FOR

HE

AT C

ALL

.

NO

TE:

ER

M W

ILL

NO

T S

UP

PO

RT

SE

RIE

S20

OP

ER

ATI

ON

. WH

EN

CO

NFI

GU

RE

D A

S A

BO

ILE

R, T

HE

Y R

ELA

Y S

HA

LL B

E O

FF A

T A

LL T

IME

S.

33-00135EFS_E.book Page 5 Tuesday, February 18, 2020 3:52 PM

Page 6: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 6

INSTALLATIONIMPORTANT

• The ERM is not compatible with RedLink Zone boards.• To ensure that the ERM will receive a wireless signal at the

desired installation location, follow steps 1 to 5 in the Wiring section.

• If your location has metal siding, the ERM’s signal may be affected. If there is no communication or poor signal strength, consider a different location.

• A Prestige (with EIM) or VisionPRO (with or without EIM) will only allow one of the following configurations: 1) Enrolled with a single boiler configured ERM; 2) Enrolled with a single compressor configured ERM; 3) Enrolled with a single boiler configured ERM and enrolled with a single compressor configured ERM.

Wiring1. Make sure power to compressor/boiler is off.2. Remove the front cover by loosening the cover screw and lifting

up from the bottom of the ERM.3. Remove 3 to 4 inches of the cable’s outer sheathing, then

remove 3/8 to 1/2 inch of insulation from each wire.

Fig. 4. Cable prepared for wiring.M35674

33-00135EFS_E.book Page 6 Tuesday, February 18, 2020 3:52 PM

Page 7: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

7 33-00135EFS—09

4. For compressor applications: Leave the jumper between termi-nals J and R in place.For boiler applications: Remove the jumper between terminals J and R.

Fig. 5. Terminal Designations showing the jumper between J and R terminals.

5. For compressors and boilers: Connect a 24 VAC power source to the R and C terminals on the ERM.

Fig. 6.

6. Connect terminals from the ERM to the appropriate terminals on the compressor/boiler control board.

MCR35657

C Y D L S1 S1FOR COMPRESSOR:Jumper J and R

FOR BOILER:Remove Jumper

J R O/BT

Y2T

M35658

C Y D L S1 S1

24V CAN COME FROM AIR HANDLER (COMPRESSOR APPLICATION)OR EXTERNAL TRANSFORMER

J R O/BT

Y2T

24VAC

V c.a.

33-00135EFS_E.book Page 7 Tuesday, February 18, 2020 3:52 PM

Page 8: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 8

COMPRESSOR

Fig. 7.

BOILER

Fig. 8.

IMPORTANTIf the ERM was previously used with a compressor and will now be used with a boiler: 1) un-enroll the ERM at the thermostat; 2) remove the jumper on the ERM; 3) designate Radiant Heat for Heating System Type

(ISU 2000) in your thermostat.

M35668

C Y D L S1 S1J R O/BT

Y2T

C Y D LR Y2 O/B

24VAC

V c.a.

10K OHM OUTDOORTEMPERATURE SENSOR (OPTIONAL)

EQUIPMENT CONTROL BOARD

M35673

C Y D L S1 S1J R O/BT

Y2T

T

EQUIPMENT CONTROL

BOARD

10K OHM INDOORTEMPERATURE SENSOR(RECOMMENDED)

T24VAC

V c.a.

33-00135EFS_E.book Page 8 Tuesday, February 18, 2020 3:52 PM

Page 9: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

9 33-00135EFS—09

Once power is connected, the “Compressor” (or “Boiler”) LED should illuminate green. (Fig. 9)

Fig. 9.

7. For compressors and boilers: Put the thermostat in pairing mode.New thermostat installation: When going through the initial setup the

thermostat display will ask “TSTAT CONTROLS AN EQUIP MODULE”. This refers to an EIM, not an ERM. See note below. The next screen says “connect RedLINK Accessories?” The ERM is an accessory, so select “yes”, and then “next”.

Existing thermostat installation: Select menu - installer options - wireless manager - add device. See thermostat installation guide for assistance.

NOTE: The ERM (equipment remote module) is not an EIM (equipment interface module).• If using a Prestige IAQ thermostat, the EIM (THM5421R) is

always needed, whether the ERM is used or not.• If using a RedLINK VisionPRO model, the EIM is not needed

if:(a) there are wire connections to R and C at the

thermostat subbase and the thermostat controls hot water heat only (no cooling).

(b) the R and C as well as furnace or air-handler wires are connected to the subbase of the thermostat.

8. Once the thermostat is in pairing mode, press and quickly release the “Connect” button on the ERM.

ORMCR35659

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

MCR35660

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

33-00135EFS_E.book Page 9 Tuesday, February 18, 2020 3:52 PM

Page 10: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 10

When the ERM is connected to the system, the ERM’s “Connected” LED will be solid green and the thermostat will show “ERM” in its Wireless Manager. (Fig. 10)

Fig. 10.

Mounting ERM9. Use two screws and wall anchors to attach the ERM to the exte-

rior wall near the compressor. The location should be at least 3 feet above ground and oriented with the two wire exits fac-ing downward. See Figs. 11 and 12.

10. Attach cover and secure with bottom screw (Fig. 13).

Fig. 11. Mounting orientation.

OR

MCR35661

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

MCR35662

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

MCR35665

MOUNTING SCREWS

CORRECT

Equipment Remote Module I ERM5000R

CompressorBoiler

Connected

Connect

CONNECTED LED STATUSFlashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor:Jump J and R

Boiler:Remove Jumper

J R C Y1 Y2T

O/BT D L S1 S1

INCORRECTINCORRECT

Eq

uip

men

t R

emot

e M

odul

e I E

RM

5000

R

Com

pre

ssor

Boi

ler

Con

nect

ed

Con

nect

CO

NN

EC

TED

LE

D S

TATU

SFl

ashi

ng: D

evic

e C

onne

ctin

gG

reen

: D

evic

e C

onne

cted

Red

: Not

Com

mun

icat

ing

Com

pres

sor:

Jum

p J

and

R

Boi

ler:

Rem

ove

Jum

per

JR

CY1

Y2 TO/B T

DL

S1S1

Equipment Remote Module I ERM5000R

CompressorBoiler

Connected

Connect

CONNECTED LED STATUSFlashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor:Jump J and R

Boiler:Remove Jumper

JRCY1Y2T

O/BTDLS1S1

33-00135EFS_E.book Page 10 Tuesday, February 18, 2020 3:52 PM

Page 11: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

11 33-00135EFS—09

Fig. 12. If mounting on lap siding, allow space for the cover to be removed.

Fig. 13.

M35666

MINIMUM 1/4 INCH GAP

M35667

33-00135EFS_E.book Page 11 Tuesday, February 18, 2020 3:52 PM

Page 12: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 12

CheckoutPower the system on. Use the thermostat to start a cooling or heating cycle, testing the ERM.

1. Restore power to the compressor/boiler as well as your RedLink system.

2. Raise/lower the set point on the zone thermostat to initiate a call for heat/cooling.

3. Observe all control devices to ensure operation and heat/cool-ing is active.

4. Lower/raise the set point on the thermostat to suspend the call for heat/cooling.

5. If outdoor temperature sensor is used, check thermostat to see the readings are active and accurate.

6. Be sure to set thermostat to the desired settings when checkout is complete.

Fig. 14.

M35680

33-00135EFS_E.book Page 12 Tuesday, February 18, 2020 3:52 PM

Page 13: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

13 33-00135EFS—09

TROUBLESHOOTINGNOTE: Disconnect RedLink™ when making changes to the device.

RESET PROCEDURE:Hold down the “Connect” button on the ERM for 10 seconds. The “Connection” LED should appear red for a few seconds and go out. This indicates the unit is reset.

Symptom Possible Cause ActionRelays don’t switch as expected

Incorrect jumper configuration

Check jumper configuration. If incorrect, unenroll from system, change jumper, then re-enroll with system.

Connected LED is red Loss of communication with system

Verify thermostat and/or Equipment Interface Module are powered and functioning correctly.

Connected LED is off Device is not enrolled with system

Enroll with system.

No LEDs are on No power to device Verify 24 VAC at R/C terminals.

33-00135EFS_E.book Page 13 Tuesday, February 18, 2020 3:52 PM

Page 14: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 14

No outdoor temperature shown on thermostat

No wired outdoor temperature sensor connected to ERM, or device configured as boiler

Connect outdoor temperature sensor to S1/S1 terminals.

Device only reports outdoor temperature temperature when configured as compressor.

Thermostat shows “—” for outdoor temperature

Wired outdoor temperature sensor failed

Check sensor for short circuit or open circuit.

Outdoor temperature reading at thermostat is too high

Sun load on sensor Verify outdoor temperature sensor is not in direct sunlight. May need to use longer wire to mount in ideal location.

Compressor doesn’t turn on, “Y” LED is blinking

5-minute compressor lockout after power cycle

Wait 5 minutes, compressor will turn on after safety timeout.

Emergency backup control doesn’t function(if configured as boiler)

No valid indoor temperature sensor

Check sensor for short circuit or open circuit, or install indoor temperature sensor on S1/S1 terminals.

Symptom Possible Cause Action

33-00135EFS_E.book Page 14 Tuesday, February 18, 2020 3:52 PM

Page 15: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

15 33-00135EFS—09

SPECIFICATIONSOperating Ambient Temperature Range:

Compressor: -40 to +155 ºF (-40 to +68 ºC)Boiler: 30 to +130 ºF (-1 to +54 ºC)

Operating Relative Humidity Range: 0 - 99 %

Electrical:24 VAC, 50/60 Hz.

Dimensions:175 mm x 168 mm x 38 mm

Wireless capability via RedLink™ technology.

Fig. 15. Dimensions.

M35664

6-7/8 (175)

6-39/64(168)

1-31/64(38)

33-00135EFS_E.book Page 15 Tuesday, February 18, 2020 3:52 PM

Page 16: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 16

SEPARABLE PARTSERM with TH8321R1001/U: YERM5220R8321

ERM with TH8321R1001/U and THM5421R1021: YERM5220RVPEIM

FCC REGULATIONS§ 15.19 (A)(3)This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. This device may not cause harmful interference, and 2. this device must accept any interference received, including

interference that may cause undesired operation.

IC REGULATIONSRSS-GENThis device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:

1. This device may not cause interference; and2. This device must accept any interference, including interference

that may cause undesired operation of the device.

FCC WARNING(§15.21) (USA ONLY)Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

33-00135EFS_E.book Page 16 Tuesday, February 18, 2020 3:52 PM

Page 17: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

17 33-00135EFS—09

5 YEAR WARRANTY Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of five (5) years from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option).

If the product is defective,(i) return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or(ii) call Resideo Customer Care at 1-800-633-3991. Customer Care will make the determination whether the product should be returned to the following address: Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage which occurred while the product was in the possession of a consumer.

Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE FIVE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-633-3991.

33-00135EFS_E.book Page 17 Tuesday, February 18, 2020 3:52 PM

Page 18: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 18

33-00135EFS_E.book Page 18 Tuesday, February 18, 2020 3:52 PM

Page 19: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

19 33-00135EFS—09

33-00135EFS_E.book Page 19 Tuesday, February 18, 2020 3:52 PM

Page 20: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

© 2020 Resideo Technologies, Inc. All rights reserved.The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées.Todos los derechos reservados. La marca comercial Honeywell Home se utiliza bajo licencia de Honeywell International, Inc. Este producto es fabricado por Resideo Technologies, Inc. y sus afiliados.

www.resideo.com

Resideo Technologies, Inc.1985 Douglas Drive North, Golden Valley, MN 554221-800-468-150233-00135EFS—09 M.S. Rev. 02-20 | Printed in United States

33-00135EFS_E.book Page 20 Tuesday, February 18, 2020 3:52 PM

Page 21: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

GUIDE D’INSTALLATION

33-00135EFS-09

ERM5220RModule d'équipement à distance (ERM)AVEC TECHNOLOGIE SANS FIL REDLINK™

Table des matièresÀ propos du module ERM5220R 2

Liste de vérification pour l’installation 3

Désignations des bornes 4

Installation 6

Vérification 13

Dépannage 15

Caractéristiques 17

Garantie de 5 ans 19

MISE EN GARDELire cette notice d'installation dans son intégralité et bien respecter les instructions.L’installation doit être effectuée par un technicien d’entretien qualifié et conformément aux codes locaux en vigueur.Couper l’alimentation vers l’appareil avant d’installer ou de réparer ce module ERM.Un raccordement de cet appareil non conforme à ces instructions peut endommager l’appareil ou les régulateurs et causer des blessures.

33-00135EFS_E.book Page 1 Tuesday, February 18, 2020 3:52 PM

Page 22: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 2

À propos du module ERM5220R

Fig. 1.

• Communication sans fil RedLink™ entre le unité de condensation/compresseur ou la chaudière et le thermostat.

• Élimine la nécessité d'acheminer des fils supplémentaires vers l'équipement, pour la mise à niveau d'une thermopompe par exemple.

• Compatible avec une utilisation à l'extérieur.• Bornes de capteur de température pour capteurs de température

extérieure ou protection antigel intérieure.• Témoins DEL pour une vérification aisée de l'installation.• L'absence de câblage et de perçage peut minimiser les dommages

de l'habitation.

REMARQUE : Le module ERM5220R est compatible avec les modèles THX9421R5021, TH8321R1001, TH8320R1003 et TH8110R1008 mis à jour. Le module de l'interface de l'équipement THM5421R1021 est également requis avec le modèle THX-9421R5021. Il est optionnel avec les autres modèles.

MFCR35654

MODULE ERMFIL

UNITÉ DE CONDENSATION

THERMOSTAT

MODULE ERM

CHAUDIÈRE

33-00135EFS_E.book Page 2 Tuesday, February 18, 2020 3:52 PM

Page 23: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

3 33-00135EFS—09

Liste de vérification pour l’installationMATÉRIEL FOURNI :

• ERM5220R• Ancres murales (2) et vis de montage (2)• Vis de couvercle supplémentaire (en option)• Notice d'installationOUTILS REQUIS (NON FOURNIS) :

• Perceuse• Douille tourne-écrou pour la perceuse• Dénudeur de fils• Petit tournevis plat• Tournevis cruciforme• Transformateur 120/240 V à 24 V (en option)

M35671

INSTALL GUIDE

33-00135EFS-03

ERM5220REquipment Remote ModuleWITH REDLINK™ WIRELESS TECHNOLOGY

Table of ContentsAbout the ERM5220R 2

Installation Checklist 3

Terminal Designations 4

Installation 6

Checkout 12

Troubleshooting 14

Specifications 16

5 Year Warranty 18

CAUTIONRead these installation instructions completely and follow them carefully.Installation must be performed by a qualified service technician and must comply with local codes.Disconnect power to all relevant devices before installing or servicing the ERM.Failure to connect the device according to these instructions may result in damage to the device, the controls, and/or personal injury.

M35669M35672

M35670

33-00135EFS_E.book Page 3 Tuesday, February 18, 2020 3:52 PM

Page 24: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 4

Désignations des bornes

Fig. 2. Désignations des bornes pour le compresseur.

MF3

5655

JRCYDLS1S1

BO

RN

ES

PO

UR

CA

PTE

UR

DE

TE

MP

ÉR

ATU

RE

10

K O

HM

S. P

EU

VE

NT

ÊTR

E U

TILI

ES

PO

UR

TEC

TER

LE

S T

EM

RAT

UR

ES

EX

TÉR

IEU

RE

S

QU

I SE

RO

NT

AFF

ICH

ÉE

S S

UR

UN

TH

ER

MO

STA

T R

edLI

NK

CO

MPA

TIB

LE.

BO

RN

E D

E D

ÉFA

ILLA

NC

E D

E L

IGN

E D

U C

OM

PR

ES

SE

UR

. L'O

CC

UR

RE

NC

E D

E L

A D

ÉFA

ILLA

NC

E S

ER

A C

OM

MU

NIQ

E A

U T

HE

RM

OS

TAT

Red

LIN

K C

OM

PATI

BLE

.

BO

RN

E D

E D

ÉG

IVR

AG

E D

U C

OM

PR

ES

SE

UR

. L'O

CC

UR

RE

NC

E D

U D

ÉG

IVR

AG

E S

ER

A C

OM

MU

NIQ

E A

U T

HE

RM

OS

TAT

Red

LIN

K C

OM

PATI

BLE

.

BO

RN

E O

/B P

OU

R L

A V

AN

NE

D'IN

VE

RS

ION

DE

LA

TH

ER

MO

PO

MP

E.

DE

UX

IÈM

E É

TAG

E D

U C

OM

PR

ES

SE

UR

À D

EU

X É

TAG

ES

.

PR

EM

IER

ÉTA

GE

DU

CO

MP

RE

SS

EU

R À

DE

UX

ÉTA

GE

S.

BO

RN

ES

PO

UR

ALI

ME

NTA

TIO

N 2

4 V

C.A

.

BO

RN

E P

OU

R C

AVA

LIE

R. L

E C

AVA

LIE

R E

NTR

E J

ET

R D

OIT

ÊTR

E E

N P

LAC

E P

OU

R L

'AP

PLI

CAT

ION

AV

EC

CO

MP

RE

SS

EU

R.

LA B

OR

NE

D S

ERT

D'E

NTR

ÉE P

OU

R L

E D

ÉGIV

RA

GE.

L'E

NTR

ÉE A

CTI

VE S

UR

LA

BO

RN

E D

ALI

MEN

TE A

UX1

. SI C

ELA

N'E

ST

PAS

SO

UH

AIT

É, N

E PA

S

BR

AN

CH

ER L

A B

OR

NE

D A

U M

OD

ULE

ER

M52

20R

. CET

TE F

ON

CTI

ON

N'E

ST

AC

TIVE

QU

E LO

RS

QU

E LE

MO

DU

LE E

RM

5220

R E

ST

CO

NFI

GU

PO

UR

UN

E U

TILI

SAT

ION

AVE

C U

N C

OM

PR

ESS

EUR

.

SIG

NA

TIO

NS

DE

S B

OR

NE

S P

OU

R L

E C

OM

PR

ES

SE

UR

O/BT

Y2T

1

1

33-00135EFS_E.book Page 4 Tuesday, February 18, 2020 3:52 PM

Page 25: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

5 33-00135EFS—09

Fig. 3. Désignations des bornes pour la chaudière.

MF3

5656

A

JRCYO/B

TDLS1S1

BO

RN

ES

PO

UR

CA

PTE

UR

DE

TE

MP

ÉR

ATU

RE

10

K O

HM

S. P

EU

T Ê

TRE

UTI

LIS

É P

OU

R L

A P

RO

TEC

TIO

N C

ON

TRE

LE

GE

L E

N C

AS

D

E P

ER

TE D

E S

IGN

AL

EN

TRE

LE

TH

ER

MO

STA

T E

T LE

MO

DU

LE E

RM

. LE

CA

PTE

UR

DO

IT R

ES

TER

À L

'INTÉ

RIE

UR

PO

UR

ÊTR

E

UTI

LIS

É C

OM

ME

PR

OTE

CTI

ON

CO

NTR

E L

E G

EL.

BO

RN

E P

OU

R A

PP

EL

DE

CH

AU

FFA

GE

.

BO

RN

ES

PO

UR

ALI

ME

NTA

TIO

N 2

4 V

C.A

.

BO

RN

E P

OU

R C

AVA

LIE

R. L

E C

AVA

LIE

R E

NTR

E J

ET

R D

OIT

ÊTR

E R

ETI

PO

UR

L'A

PP

LIC

ATIO

N A

VE

C C

HA

UD

IÈR

E.

SIG

NA

TIO

NS

DE

S B

OR

NE

S P

OU

R L

A C

HA

UD

IÈR

E

Y2T

BO

RN

E P

OU

R A

PP

EL

DE

CH

AU

FFA

GE

.

RE

MA

RQ

UE

: L'

ER

M N

'ES

T P

AS

CO

MP

ATI

BLE

AV

EC

LA

RIE

20.

PO

UR

LE

S A

PP

LIC

ATI

ON

S A

VE

C C

HA

UD

IÈR

E, L

E R

ELA

IS Y

ES

T

SA

CTI

EN

PE

RM

AN

EN

CE

.

33-00135EFS_E.book Page 5 Tuesday, February 18, 2020 3:52 PM

Page 26: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 6

INSTALLATIONIMPORTANT

• Le module ERM n'est pas compatible avec les tableaux de zone RedLink.

• Pour s'assurer que le module ERM recevra un signal sans fil à l'emplacement souhaité pour l'installation, suivre les étapes 1 à 5 de la section Câblage.

• Si l'emplacement comporte un bardage métallique, le signal de l'ERM peut en être affecté. En cas d'absence de communication ou d'inten-sité insuffisante du signal, considérer un autre emplacement.

• Les thermostats Prestige (avec EIM) ou VisionPRO (avec ou sans EIM) ne permettront que l'une des configurations suivantes : 1) Enregistrement avec un ERM configuré pour une seule chaudière; 2) Enregistrement avec un ERM configuré pour un seul com-presseur; 3) Enregistrement avec un ERM configuré pour une seule chaudière et enregistrement avec un ERM configuré pour un seul compresseur.

Câblage1. S'assurer que l'alimentation vers le compresseur/la chaudière

est coupée.2. Retirer le couvercle avant en desserrant la vis du couvercle et en

le relevant du bas de l'ERM.3. Retirer 3 à 4 pouces de la gaine extérieure du câble, puis retirer

3/8 à 1/2 pouce d'isolation de chaque fil.

Fig. 4. Câble préparé pour le raccordement.M35674

33-00135EFS_E.book Page 6 Tuesday, February 18, 2020 3:52 PM

Page 27: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

7 33-00135EFS—09

4. Pour les applications avec compresseur : Laisser le cavalier en place entre les bornes J et R.Pour les applications avec chaudière : Retirer le cavalier entre les bornes J et R.

Fig. 5. Désignations des bornes montrant le cavalier entre les bornes J et R.

5. Pour les compresseurs et les chaudières : Brancher une source d'alimentation de 24 V c.a. sur les bornes R et C du module ERM.

Fig. 6.

6. Connecter les bornes du module ERM aux bornes appropriées du tableau de contrôle du compresseur/de la chaudière.

MCR35657

C Y D L S1 S1FOR COMPRESSOR:Jumper J and R

FOR BOILER:Remove Jumper

J R O/BT

Y2T

MF35658

C Y D L S1 S1

24 V PROVENANT DU SYSTÈME DE TRAITEMENT DE L'AIR (APPLICATION AVEC COMPRESSEUR) OU D'UN TRANSFORMATEUR EXTERNE

J R O/BT

Y2T

24V c.a.

33-00135EFS_E.book Page 7 Tuesday, February 18, 2020 3:52 PM

Page 28: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 8

COMPRESSEUR

Fig. 7.

CHAUDIÈRE

Fig. 8.

MF35668

C Y D L S1 S1J R O/BT

Y2T

C Y D LR Y2 O/B

24V c.a.

CAPTEUR DE TEMPÉRATURE EXTÉRIEURE 10 K OHMS (EN OPTION)

TABLEAU DE CONTRÔLE DE L'ÉQUIPEMENT

MF35673

C Y D L S1 S1J R O/BT

Y2T

T

TABLEAU DE CONTRÔLE DE L'ÉQUIPEMENT

CAPTEUR DE TEMPÉRATUREINTÉRIEURE 10 K OHMS (RECOMMANDÉ)

T24V c.a.

33-00135EFS_E.book Page 8 Tuesday, February 18, 2020 3:52 PM

Page 29: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

9 33-00135EFS—09

IMPORTANTSi le module ERM a précédemment été utilisé avec un compresseur et est maintenant destiné à être utilisé avec une chaudière : 1) annuler l'enregistrement du module ERM sur le thermostat; 2) retirer le cavalier du module ERM; 3) indiquer Radiant Heat for Heating System Type (ISU 2000) (Chauffage rayonnant pour type de système de chauffage) sur le thermostat.

Une fois l'alimentation connectée, le témoin DEL « Compressor » (Compresseur) ou « Boiler » (Chaudière) devrait s'allumer en vert. (Fig. 9)

Fig. 9.

7. Pour les compresseurs et les chaudières : Mettre le thermostat en mode d'appairage.Installation d'un nouveau thermostat : Lors de la configuration

initiale, l'écran du thermostat demandera « TSTAT CONTROLS AN EQUIP MODULE ». Ceci fait référence à un module EIM, et non à un module ERM. Voir la remarque ci-dessous. L'écran suivant invitera à « Connect RedLINK Accessories? » (Brancher les accessoires RedLINK?), Le module ERM est un accessoire, sélectionner « yes » (oui), puis « next » (suivant).

Installation d'un thermostat existant : Sélectionner menu - options de l'installateur - gestionnaire des dispositifs - ajouter un dispositif. Voir la notice d'installation du thermostat pour obtenir de l’aide.

OUMCR35659

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

MCR35660

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

33-00135EFS_E.book Page 9 Tuesday, February 18, 2020 3:52 PM

Page 30: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 10

REMARQUE : Le module ERM (module à distance d'équipement) n'est pas un module EIM (module d'interface d'équipement)..• Lors de l'utilisation d'un thermostat Prestige IAQ, un module

EIM (THM5421R) est toujours nécessaire, qu'un module ERM soit utilisé ou non.

• Lors de l'utilisation du modèle RedLINK VisionPRO, le module EIM n'est pas nécessaire si :

(a) il y a des connexions de câblage à R et C à la plaque de raccordement et que le thermostat ne contrôle que le chauffage de l'eau (pas de refroidissement).

(b) les fils R et C ainsi que ceux de l'appareil de chauffage ou de traitement de l’air sont connectés à la plaque de raccordement du thermostat.

8. Une fois le thermostat en mode d'appairage, appuyer rapide-ment sur le bouton « Connect » (Connexion) sur le module ERM.

Une fois le module ERM connecté au système, son témoin DEL de connexion s'allume en vert en continu et le thermostat indique « ERM » dans le gestionnaire des dispositifs sans fil. (Fig. 10)

Fig. 10.

OU

MCR35661

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

MCR35662

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

33-00135EFS_E.book Page 10 Tuesday, February 18, 2020 3:52 PM

Page 31: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

11 33-00135EFS—09

Montage du module ERM9. Utiliser deux vis et deux ancres murales pour fixer le module

ERM sur le mur extérieur près du compresseur. L'emplacement doit être situé à au moins 3 pieds au-dessus du sol et orienté avec les deux sorties de fil face vers le bas. Voir les Figs. 11 et 12.

10. Attacher le couvercle et le fixer avec la vis inférieure (Fig. 13).

Fig. 11. Orientation de montage.

MFCR35665

VIS DE MONTAGE

CORRECTE

Equipment Remote Module I ERM5000R

CompressorBoiler

Connected

Connect

CONNECTED LED STATUSFlashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor:Jump J and R

Boiler:Remove Jumper

J R C Y1 Y2T

O/BT D L S1 S1

INCORRECTEINCORRECTE

Eq

uip

men

t R

emot

e M

odul

e I E

RM

5000

R

Com

pre

ssor

Boi

ler

Con

nect

ed

Con

nect

CO

NN

EC

TED

LE

D S

TATU

SFl

ashi

ng: D

evic

e C

onne

ctin

gG

reen

: D

evic

e C

onne

cted

Red

: Not

Com

mun

icat

ing

Com

pres

sor:

Jum

p J

and

R

Boi

ler:

Rem

ove

Jum

per

JR

CY1

Y2 TO/B T

DL

S1S1

Equipment Remote Module I ERM5000R

CompressorBoiler

Connected

Connect

CONNECTED LED STATUSFlashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor:Jump J and R

Boiler:Remove Jumper

JRCY1Y2T

O/BTDLS1S1

33-00135EFS_E.book Page 11 Tuesday, February 18, 2020 3:52 PM

Page 32: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 12

Fig. 12. Si le montage a lieu sur un bardage à clin, laisser suffisamment d'espace pour permettre le retrait du couvercle.

Fig. 13.

MF35666

ESPACEMENT MINIMUM 1/4 PO

M35667

33-00135EFS_E.book Page 12 Tuesday, February 18, 2020 3:52 PM

Page 33: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

13 33-00135EFS—09

VérificationMettre le système sous tension. Utiliser le thermostat pour lancer un cycle de chauffage ou de refroidissement pour tester le module ERM.

1. Restaurer l'alimentation vers le compresseur/la chaudière ainsi que vers le système RedLink.

2. Hausser/réduire le point de consigne sur le thermostat de zone pour lancer un appel de chauffage/refroidissement.

3. Observer tous les dispositifs de régulation pour vérifier qu'ils fonctionnent bien et que le chauffage/refroidissement est actif.

4. Réduire/hausser le point de consigne sur le thermostat pour lancer un appel de chauffage/refroidissement.

5. Si le capteur de température extérieure est utilisé, vérifier que les valeurs indiquées sur le thermostat sont actives et précises.

6. Veiller à régler le thermostat aux réglages désirés une fois la vérification terminée.

33-00135EFS_E.book Page 13 Tuesday, February 18, 2020 3:52 PM

Page 34: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 14

Fig. 14.

M35680

33-00135EFS_E.book Page 14 Tuesday, February 18, 2020 3:52 PM

Page 35: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

15 33-00135EFS—09

DÉPANNAGEREMARQUE : Débrancher le système RedLink™ avant de procéder à

des modifications sur le dispositif.

PROCÉDURE DE RÉINTIALISATION :Appuyer pendant 10 secondes sur le bouton « Connect » (Connexion) du module ERM. Le témoin DEL de connexion doit s'allumer en rouge pendant quelques secondes, puis s'éteindre. Ceci indique que l'unité a été réinitialisée.

Symptôme Cause possible ActionLes relais ne s'enclenchent pas comme prévu

Configuration incorrecte du cavalier

Contrôler la configuration du cavalier. Si elle est incorrecte, annuler l'enregistrement, modifier le cavalier, puis enregistrer de nouveau l'appareil.

Le témoin DEL de connexion est rouge

Perte de communication avec le système

Vérifier que le thermostat et/ou le module d'interface d'équipement sont alimentés et fonctionnent correctement.

Le témoin DEL de connexion est éteint

L'appareil n'est pas enregistré dans le système

Enregistrer l'appareil dans le système.

Aucun témoin DEL n'est allumé

L'appareil n'est pas alimenté

Vérifier que 24 V c.a. sont présents aux bornes R/C.

Le thermostat n'affiche pas la température extérieure

Aucun capteur de température extérieure n'est connecté au module ERM, ou l'appareil est configuré sur chaudière

Brancher le capteur de température extérieur aux bornes S1/S1.

L'appareil n'indique que la température extérieure lorsqu'il est configuré sur compresseur.

33-00135EFS_E.book Page 15 Tuesday, February 18, 2020 3:52 PM

Page 36: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 16

Le thermostat indique « — » pour la température extérieure

Défaillance du capteur de température extérieure avec fil

Contrôler le capteur pour s'assurer qu'il n'y a ni court-circuit ni circuit ouvert.

La température extérieure indiquée sur le thermostat est trop élevée

Charge solaire sur le capteur

Vérifier que le capteur de température extérieure n'est pas directement exposé à la lumière solaire. Un fil plus long peut être requis pour assurer une installation adéquate.

Le compresseur ne se met pas en marche, le témoin DEL « Y » clignote

Verrouillage du compresseur de 5 minutes après le cycle de mise sous tension

Attendre 5 minutes. Le compresseur se met en marche après le délai de sécurité.

La régulation de secours en cas d'urgence ne fonctionne pas (si configurée comme chaudière)

Pas de capteur de température intérieure valide

Contrôler le capteur pour vérifier qu'il n'y a pas de court-circuit ni de circuit ouvert, ou installer le capteur de température intérieure sur les bornes S1/S1.

Symptôme Cause possible Action

33-00135EFS_E.book Page 16 Tuesday, February 18, 2020 3:52 PM

Page 37: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

17 33-00135EFS—09

CARACTÉRISTIQUESGamme de température ambiante de service :

Compresseur : -40 à +68 °C (-40 à +155 °F)Chaudière : -1 à +54 °C (30 à +130 °F)

Plage d'humidité relative de service : 0 - 99 %

Spécifications électriques :24 V c.a., 50/60 Hz.

Dimensions :175 mm x 168 mm x 38 mm

Capacité sans fil via technologie RedLink™.

Fig. 15. Dimensions.

M35664

6-7/8 (175)

6-39/64(168)

1-31/64(38)

33-00135EFS_E.book Page 17 Tuesday, February 18, 2020 3:52 PM

Page 38: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 18

PIÈCES SÉPARABLESERM avec TH8321R1001/U : YERM5220R8321ERM avec TH8321R1001/U et THM5421R1021 : YERM5220RVPEIM

RÈGLEMENTS DE LA FCC§ 15.19 (A)(3)Ce dispositif est conforme à la Partie 15 du règlement de la FCC. Le fonctionnement est soumis aux deux conditions suivantes :

1. Ce dispositif ne doit pas causer d’interférences nuisibles, et 2. Ce dispositif doit accepter toutes les interférences reçues, y

compris celles pouvant causer un fonctionnement non souhaité.

RÉGLEMENTATION ICRSS-GENLe présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :

1. l’appareil ne doit pas produire de brouillage;2. l’utilisateur de l’appareil doit accepter tout brouillage

radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

AVERTISSEMENT DE LA FCC(§15.21) (ÉTATS-UNIS UNIQUMENT)Toute modification qui n'est pas autorisée expressément par la partie responsable de la conformite de l'appareil peut rendre l'utilisateur inapte a faire fonctionner l'équipment.

33-00135EFS_E.book Page 18 Tuesday, February 18, 2020 3:52 PM

Page 39: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

19 33-00135EFS—09

GARANTIE DE 5 ANSResideo garantit ce produit, à l’exception des piles, contre tout défaut de pièce ou de main-d’oeuvre, durant une période pour cinq (5) ans à partir de la date d’achat par le consommateur d’origine si le produit est utilisé et entretenu convenablement. En cas de défaillance ou de mauvais fonctionnement pendant la période de garantie, Resideo remplacera ou réparera le produit, à sa discrétion.

Si le produit est défectueux(i) renvoyez-le avec la facture ou une autre preuve d’achat date au lieu d’achat; ou(ii) appelez le service à la clientèle de Resideo en composant le 1-800-633-3991. Le service à la clientèle déterminera si le produit doit être retourné à l’adresse suivante : Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, ou si un produit de remplacement peut vous être expédié.

La présente garantie ne couvre pas les frais de retrait ou de réinstallation. La présente garantie ne s’applique pas s’il est démontré par Resideo que la défaillance ou le mauvais fonctionnement sont dus à un endommagement du produit alors que le consommateur l’avait en sa possession.

La responsabilité exclusive de Resideo se limite à réparer ou à remplacer le produit conformément aux modalités susmentionnées. RESIDEO N’EST EN AUCUN CAS RESPONSABLE DES PERTES OU DOMMAGES, Y COMPRIS LES DOMMAGES INDIRECTS OU ACCESSOIRES DÉCOULANT DIRECTEMENT OU INDIRECTEMENT D’UNE VIOLATION QUELCONQUE D’UNE GARANTIE, EXPRESSE OU TACITE, APPLICABLE AU PRÉSENT PRODUIT, OU TOUTE AUTRE DÉFAILLANCE DU PRÉSENT PRODUIT. Certaines provinces ne permettent pas l’exclusion ou la restriction des dommages indirects ou accessoires et, par conséquent, la présente restriction peut ne pas s’appliquer.

CETTE GARANTIE EST LA SEULE GARANTIE EXPRESSE FAITE PAR RESIDEO POUR CE PRODUIT. LA DURÉE DE TOUTE GARANTIE IMPLICITE, INCLUANT LES GARANTIES DE QUALITÉ MARCHANDE OU D’ADAPTATION À UNE UTILISATION PARTICULIÈRE, EST LIMITÉE PAR LES PRÉSENTES À LA PÉRIODE À CINQ ANNÉES DE LA PRÉSENTE GARANTIE. Certaines provinces ne permettent pas de limiter la durée des garanties tacites et, par conséquent, la présente limitation peut ne pas s’appliquer.

La présente garantie donne au consommateur des droits spécifiques et certains autres droits qui peuvent varier d’une province à l’autre.

Pour toute question concernant la présente garantie, prière d’écrire aux Services à la clientèle de Resideo à l’adresse suivante : Resideo Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 ou composer le 1-800-633-3991.

33-00135EFS_E.book Page 19 Tuesday, February 18, 2020 3:52 PM

Page 40: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

© 2020 Resideo Technologies, Inc. All rights reserved.The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées.Todos los derechos reservados. La marca comercial Honeywell Home se utiliza bajo licencia de Honeywell International, Inc. Este producto es fabricado por Resideo Technologies, Inc. y sus afiliados.

www.resideo.com

Resideo Technologies, Inc.1985 Douglas Drive North, Golden Valley, MN 554221-800-468-150233-00135EFS—09 M.S. Rev. 02-20 | Imprimé aux Étas-Unis

33-00135EFS_E.book Page 20 Tuesday, February 18, 2020 3:52 PM

Page 41: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

GUÍA DE INSTALACIÓN

33-00135EFS-09

Módulo de acceso remoto al equipo ERM5220RCON TECNOLOGÍA INALÁMBRICA REDLINK™

ÍndiceSobre el ERM5220R 2

Lista de verificación para la instalación 3

Designación de los terminales: 4

Instalación 6

Verificación 13

Localización y solución de problemas 14

Especificaciones 16

Garantía de 5 Años 19

PRECAUCIÓNLea todas las instrucciones de instalación y cumpla con estas atentamente.La instalación la debe realizar un técnico de servicio calificado y debe cumplir con los códigos locales.Desconecte el suministro de energía eléctrica hacia todos los dispositivos relevantes antes de instalar o prestar servicio al ERM.No conectar el dispositivo según estas instrucciones, puede ocasionar daños al dispositivo, los controles y/o lesiones personales.

33-00135EFS_E.book Page 1 Tuesday, February 18, 2020 3:52 PM

Page 42: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 2

Sobre el ERM5220R

Fig. 1.

• Comunicación inalámbrica RedLink™ entre el unidad de condensación/compresor o la caldera y el termostato.

• Elimina la necesidad de pasar cables adicionales a su equipo, por ejemplo, durante una actualización de la bomba de calor.

• Apto para uso exterior.• Terminales de sensor de temperatura para protección de los

sensores de temperatura exteriores o de congelamiento en interiores.

• Los LED para revisión fácil de la instalación.• Puede disminuir el daño a los hogares debido a que se elimina el

cableado/las perforaciones.

NOTA: El ERM5220R es compatible con los modelos actualizados THX9421R5021, TH8321R1001, TH8320R1003, y TH8110R1008. El THM5421R1021 EIM también es necesario con el modelo THX-9421R5021. Opcional con otros modelos.

MSCR35654

ERMCABLE

UNIDAD DE CONDENSACIÓN

TERMOSTATO

ERM

CALDERA

33-00135EFS_E.book Page 2 Tuesday, February 18, 2020 3:52 PM

Page 43: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

3 33-00135EFS—09

Lista de verificación para la instalaciónMATERIALES PROPORCIONADOS:

• ERM5220R• Tarugos de pared (2) y tornillos de montaje (2)• Tornillo para cubierta adicional (opcional)• Instrucciones de instalación

HERRAMIENTAS NECESARIAS (NO SE SUMINISTRAN):

• Taladro• Accesorio de inserción de tuercas para uso con el taladro• Pelacables• Destornillador pequeño de hoja plana• Destornillador de estrella• Transformador de 120/240 V a 24 V (opcional)

M35671

INSTALL GUIDE

33-00135EFS-03

ERM5220REquipment Remote ModuleWITH REDLINK™ WIRELESS TECHNOLOGY

Table of ContentsAbout the ERM5220R 2

Installation Checklist 3

Terminal Designations 4

Installation 6

Checkout 12

Troubleshooting 14

Specifications 16

5 Year Warranty 18

CAUTIONRead these installation instructions completely and follow them carefully.Installation must be performed by a qualified service technician and must comply with local codes.Disconnect power to all relevant devices before installing or servicing the ERM.Failure to connect the device according to these instructions may result in damage to the device, the controls, and/or personal injury.

M35669M35672

M35670

33-00135EFS_E.book Page 3 Tuesday, February 18, 2020 3:52 PM

Page 44: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 4

Designación de los terminales:

Fig. 2. Designación de los terminales para el compresor.

MS

3565

5

JRCYDLS1S1

TER

MIN

ALE

S P

AR

A E

L S

EN

SO

R D

E T

EM

PE

RAT

UR

A D

E 1

0K O

HM

IOS

. SE

PU

ED

E U

TILI

ZA

R P

AR

A D

ETE

CTA

R L

AS

TE

MP

ER

ATU

RA

S

EX

TER

IOR

ES

QU

E S

E M

OS

TRA

N E

N U

N T

ER

MO

STA

TO R

edLI

NK

CO

MPA

TIB

LE.

TER

MIN

AL

DE

FA

LLA

DE

TU

BE

RÍA

DE

L C

OM

PR

ES

OR

. LA

FA

LLA

SE

CO

MU

NIC

AD

A A

L TE

RM

OS

TATO

Red

LIN

K C

OM

PATI

BLE

.

TER

MIN

AL

DE

DE

SC

ON

GE

LAC

IÓN

DE

L C

OM

PR

ES

OR

. LA

DE

SC

ON

GE

LAC

IÓN

SE

CO

MU

NIC

AD

A A

L TE

RM

OS

TATO

Red

LIN

K C

OM

PATI

BLE

.

TER

MIN

AL

O/B

PA

RA

INV

ER

TIR

LA

LVU

LA E

N L

A B

OM

BA

DE

CA

LOR

.

SE

GU

ND

A E

TAPA

DE

L C

OM

PR

ES

OR

DE

DO

S E

TAPA

S.

PR

IME

RA

ETA

PA D

EL

CO

MP

RE

SO

R D

E D

OS

ETA

PAS

.

TER

MIN

ALE

S P

AR

A A

LIM

EN

TAC

IÓN

DE

24

V C

A.

TER

MIN

AL

DE

L P

UE

NTE

. EL

PU

EN

TE E

NTR

E J

Y R

DE

BE

ES

TAR

EN

SU

LU

GA

R P

AR

A E

L U

SO

DE

L C

OM

PR

ES

OR

.

EL T

ERM

INA

L "D

" FU

NC

ION

A C

OM

O U

NA

EN

TRA

DA

PA

RA

DES

CO

NG

ELA

CIÓ

N. A

CTI

VAR

LA

EN

TRA

DA

EN

EL

TER

MIN

AL

"D"

ALI

MEN

TAR

Á E

L A

UX1

. S

I NO

SE

DES

EA "

D"

A A

UX1

, N

O C

ON

ECTE

EL

TER

MIN

AL

"D"

AL

ERM

5220

R.

ESTA

FU

NC

IÓN

ES

TÁ A

CTI

VA Ú

NIC

AM

ENTE

CU

AN

DO

EL

ERM

5220

RES

TÁ C

ON

FIG

UR

AD

O P

AR

A U

SO

CO

N U

N C

OM

PR

ESO

R.

DE

SIG

NA

CIÓ

N D

E L

OS

TE

RM

INA

LES

PA

RA

EL

CO

MP

RE

SO

R

O/BT

Y2T

1

1

33-00135EFS_E.book Page 4 Tuesday, February 18, 2020 3:52 PM

Page 45: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

5 33-00135EFS—09

Fig. 3. Designación de los terminales para la caldera.

MS

3565

6A

JRCYO/B

TDLS1S1

TER

MIN

ALE

S P

AR

A E

L S

EN

SO

R D

E T

EM

PE

RAT

UR

A D

E 1

0K O

HM

IOS

. SE

PU

ED

E U

TILI

ZA

R P

AR

A P

RO

TEC

CIÓ

N C

ON

TRA

CO

NG

ELA

CIÓ

N

EN

CA

SO

DE

QU

E E

L TE

RM

OS

TATO

PIE

RD

A L

A S

AL

AL

ER

M.

EL

SE

NS

OR

DE

BE

PE

RM

AN

EC

ER

EN

INTE

RIO

RE

S P

AR

A S

ER

UTI

LIZ

AD

OC

OM

O P

RO

TEC

CIÓ

N C

ON

TRA

CO

NG

ELA

CIÓ

N.

TER

MIN

AL

PAR

A D

EM

AN

DA

DE

CA

LEFA

CC

IÓN

.

TER

MIN

ALE

S P

AR

A A

LIM

EN

TAC

IÓN

DE

24

V C

A.

TER

MIN

AL

PAR

A E

L P

UE

NTE

. EL

PU

EN

TE E

NTR

E J

Y R

DE

BE

ES

TAR

EN

SU

LU

GA

R P

AR

A E

L U

SO

DE

LA

CA

LDE

RA

.

DE

SIG

NA

CIÓ

N D

E L

OS

TE

RM

INA

LES

PA

RA

LA

CA

LDE

RA

Y2T

TER

MIN

AL

PAR

A D

EM

AN

DA

DE

CA

LEFA

CC

IÓN

.

NO

TA: E

L E

RM

NO

AD

MIT

E E

L FU

NC

ION

AM

IEN

TO C

ON

LA

SE

RIE

20.

CU

AN

DO

SE

CO

NFI

GU

RA

CO

MO

UN

A C

ALD

ER

A, E

L R

ELÉ

"Y

"

DE

BE

ES

TAR

AP

AG

AD

O E

N T

OD

O M

OM

EN

TO.

33-00135EFS_E.book Page 5 Tuesday, February 18, 2020 3:52 PM

Page 46: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 6

INSTALACIÓNIMPORTANTE

• El módulo de acceso remoto al equipo (ERM) no es compatible con los tableros de zona RedLink.

• Para garantizar que el ERM reciba una señal inalámbrica en el lugar de instalación deseado, siga los pasos 1 al 5 en la sección de Cableado.

• Si el lugar tiene paneles de revestimiento de metal, la señal del ERM puede verse afectada. Si no hay comunicación o la señal tiene poca potencia, considere una ubicación diferente.

• Un Prestige (con EIM) o VisionPRO (con o sin EIM) solo permitirá una de las siguientes configuraciones: 1) Incorporado con un ERM configurado a una sola caldera; 2) Incorporado con un ERM configurado a un solo compresor; 3) Incorporado con un ERM configurado a una sola caldera e incorporado con un ERM configurado a un solo compresor.

Cableado1. Compruebe que el suministro de energía eléctrica hacia el compre-

sor/caldera esté desconectado.2. Retire la cubierta frontal aflojando el tornillo de la cubierta y

extrayéndola de la parte inferior del ERM.3. Retire 3 o 4 pulgadas (7.6 cm o 10.2 cm) del revestimiento del

cable, seguidamente retire de 3/8 a 1/2 pulgada del aislante de cada cable.

Fig. 4. Cable preparado para el cableado.

M35674

33-00135EFS_E.book Page 6 Tuesday, February 18, 2020 3:52 PM

Page 47: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

7 33-00135EFS—09

4. Para aplicaciones en el compresor: Deje el puente entre los terminales J y R en su lugar.Para aplicaciones en la caldera: Retire el puente entre los terminales J y R.

Fig. 5. Designaciones de terminales mostrando el puente entre los terminales J y R.

5. Para compresores y calderas: Conecte a una toma de energía de 24 V CA a los terminales R y C en el ERM.

Fig. 6.

6. Conecte los terminales del ERM a los terminales adecuados del tablero de control del compresor/caldera.

MCR35657

C Y D L S1 S1FOR COMPRESSOR:Jumper J and R

FOR BOILER:Remove Jumper

J R O/BT

Y2T

MS35658

C Y D L S1 S1

LOS 24 V PUEDEN PROCEDER DE UN CONTROLADOR DE AIRE (APLICACIÓN DEL COMPRESOR) O DE UN TRANSFORMADOR EXTERNO

J R O/BT

Y2T

24VAC

V c.a.

33-00135EFS_E.book Page 7 Tuesday, February 18, 2020 3:52 PM

Page 48: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 8

COMPRESOR

Fig. 7.

CALDERA

Fig. 8.

IMPORTANTESi el ERM se utilizó previamente con un compresor y ahora se utilizará con una caldera: 1) Desincorpore el ERM en el termostato; 2) Retire el puente en el ERM; 3) Designe calefacción radiante para el tipo de sistema de calefacción (ISU 2000) en su termostato

MS35668

C Y D L S1 S1J R O/BT

Y2T

C Y D LR Y2 O/B

24VAC

V c.a.

SENSOR DE 10K OHMDE TEMPERATURA EXTERIOR (OPCIONAL)

PANEL DE CONTROL DEL EQUIPO

MS35673

C Y D L S1 S1J R O/BT

Y2T

T

PANEL DE CONTROL DEL

EQUIPO

SENSOR DE 10K OHM DE TEMPERATURA INTERIOR (RECOMENDADO)

T24VAC

V c.a.

33-00135EFS_E.book Page 8 Tuesday, February 18, 2020 3:52 PM

Page 49: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

9 33-00135EFS—09

Una vez que la electricidad está conectada, el LED del "compressor" (compresor) o del "boiler" (caldera) se debe iluminar en verde. (Fig. 9)

Fig. 9.

7. Para compresores y calderas: Coloque el termostato en el modo de conexión.Instalación de termostato nuevo: Cuando ejecute los pasos de

la configuración inicial la pantalla del termostato mostrará “TSTAT CONTROLS AN EQUIP MODULE” (el termostato controla un módulo de equipo). Esto se refiere a un EIM no a un ERM. Consulte la nota que se encuentra a continuación. ¿La siguiente pantalla indica "connect RedLINK Accessories?” (¿conectar los accesorios RedLINK?) El ERM es un accesorio, de modo que seleccione "yes" (sí) y luego "next" (siguiente).

Instalación en termostato existente: Seleccione el menú - opciones del instalador - administrador inalámbrico - añadir dispositivo. Consulte la guía de instalación del termostato para obtener asistencia.

OMCR35659

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

MCR35660

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

33-00135EFS_E.book Page 9 Tuesday, February 18, 2020 3:52 PM

Page 50: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 10

NOTA: El ERM (módulo de acceso remoto al equipo) no es un EIM (módulo de interfaz del equipo).• Si utiliza un termostato Prestige IAQ, el EIM (THM5421R) se

necesita siempre, independientemente de si el ERM se utiliza o no.

• Si utiliza un modelo RedLINK VisionPRO, no se necesita el EIM si:

(a) hay conexiones de cable a R y C en la subbase del termostato y el termostato controla la calefacción por agua caliente únicamente (no la refrigeración).

(b) El R y el C, así como los cables del sistema de calefacción o la unidad de manejo del aire están conectados a la subbase del termostato.

8. Una vez que el termostato esté en el modo de conexión, presi-one y suelte rápidamente el botón "Conectar" en el ERM.

Cuando el ERM está conectado al sistema, el LED "conectado" del ERM estará verde fijo y el termostato mostrará "ERM" en su Administrador inalámbrico. (Fig. 10)

Fig. 10.

O

MCR35661

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

MCR35662

CONNECTED LED STATUS

Connect Flashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor

Boiler

Connected

33-00135EFS_E.book Page 10 Tuesday, February 18, 2020 3:52 PM

Page 51: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

11 33-00135EFS—09

Monte el ERM9. Utilice dos tornillos y tarugos de pared para fijar el ERM a la

pared exterior cerca del compresor. La ubicación debe estar por lo menos a 3 pies (91 cm) por encima del suelo y orientada con las dos salidas de cable hacia abajo. Vea las Figs. 11 y 12.

10. Fije la cubierta y asegúrela con el tornillo inferior (Fig. 13).

Fig. 11. Orientación de montaje.

MSCR35665

TORNILLOS DE MONTAJE

CORRECTA

Equipment Remote Module I ERM5000R

CompressorBoiler

Connected

Connect

CONNECTED LED STATUSFlashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor:Jump J and R

Boiler:Remove Jumper

J R C Y1 Y2T

O/BT D L S1 S1

INCORRECTAINCORRECTA

Eq

uip

men

t R

emot

e M

odul

e I E

RM

5000

R

Com

pre

ssor

Boi

ler

Con

nect

ed

Con

nect

CO

NN

EC

TED

LE

D S

TATU

SFl

ashi

ng: D

evic

e C

onne

ctin

gG

reen

: D

evic

e C

onne

cted

Red

: Not

Com

mun

icat

ing

Com

pres

sor:

Jum

p J

and

R

Boi

ler:

Rem

ove

Jum

per

JR

CY1

Y2 TO/B T

DL

S1S1

Equipment Remote Module I ERM5000R

CompressorBoiler

Connected

Connect

CONNECTED LED STATUSFlashing: Device ConnectingGreen: Device ConnectedRed: Not Communicating

Compressor:Jump J and R

Boiler:Remove Jumper

JRCY1Y2T

O/BTDLS1S1

33-00135EFS_E.book Page 11 Tuesday, February 18, 2020 3:52 PM

Page 52: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 12

Fig. 12. Si está montado sobre paneles de revestimiento, deje espacio para que se pueda retirar la cubierta.

Fig. 13.

MS35666

MÍNIMO 1/4 DE PULGADA (6.3 mm) DE SEPARACIÓN

M35667

33-00135EFS_E.book Page 12 Tuesday, February 18, 2020 3:52 PM

Page 53: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

13 33-00135EFS—09

VerificaciónActive el suministro de energía eléctrica hacia el sistema. Utilice el termostato para comenzar el ciclo de refrigeración o calefacción, probando el ERM.

1. Restituya el suministro de energía eléctrica al compresor/caldera así como al sistema RedLink.

2. Eleve/baje el punto de referencia del termostato de zona para iniciar una demanda de calefacción/refrigeración.

3. Observe todos los dispositivos de control para garantizar que el funcionamiento y la calefacción/refrigeración estén activas.

4. Baje/eleve el punto de referencia del termostato de zona para suspender la demanda de calefacción/refrigeración.

5. Si se utiliza el sensor de temperatura exterior, revise el termostato para ver si las lecturas están activas y son precisas.

6. Verifique que el termostato esté en las configuraciones deseadas cuando finalice la revisión.

Fig. 14.

M35680

33-00135EFS_E.book Page 13 Tuesday, February 18, 2020 3:52 PM

Page 54: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 14

LOCALIZACIÓN Y SOLUCIÓN DE PROBLEMASNOTA: Desconecte RedLink™ cuando haga cambios al dispositivo.

PROCEDIMIENTO PARA REINICIAR:Presione el botón "Connect" (conectar) en el ERM durante 10 segundos. El LED de la "conexión" debe aparecer en rojo durante unos segundos y después se apaga. Esto indica que la unidad está reiniciada.

Síntoma Causa posible AcciónLos relés no cambian como se espera

Configuración incorrecta del puente.

Revise la configuración del puente. Si está incorrecta, desincorpore a nivel del sistema, cambie el puente y vuelva a incorporar al sistema.

El LED conectado está rojo

Pérdida de comunicación con el sistema

Verifique que el termostato y/o el módulo de acceso remoto están alimentados y funcionando correctamente.

El LED conectado está apagado

El dispositivo no está incorporado al sistema

Incorpórelo al sistema.

Ninguno de los LED está encendido

No llega electricidad al dispositivo

Verifique que haya 24 V CA en los terminales R/C

33-00135EFS_E.book Page 14 Tuesday, February 18, 2020 3:52 PM

Page 55: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

15 33-00135EFS—09

No se muestra la temperatura exterior en el termostato

No hay sensor de temperatura de exterior cableado conectado al ERM, ni dispositivo configurado como caldera

Conecte el sensor de temperatura exterior a los terminales S1/S1.

El dispositivo solo reporta la temperatura exterior cuando está configurado como compresor.

El termostato muestra “—” para la temperatura exterior

Falla en el sensor de temperatura cableado exterior

Revise el sensor en busca de cortocircuito o circuito abierto.

La lectura de temperatura exterior del termostato es demasiado alta

Carga de sol en el sensor

Verifique que el sensor de temperatura exterior no esté bajo la luz solar directa. Puede necesitar utilizar un cable más largo para montarlo en un lugar ideal.

El compresor no se activa, el LED "Y" está parpadeando

Bloqueo del compresor durante 5 minutos después del ciclo de encendido

Espere 5 minutos, el compresor se activará después del apagado por seguridad.

El control de respaldo de emergencia no funciona (si se configura como caldera)

No hay sensor de temperatura válido en interiores

Revise el sensor en busca de cortocircuito o circuito abierto o instale el sensor de temperatura en interiores en los terminales S1/S1.

Síntoma Causa posible Acción

33-00135EFS_E.book Page 15 Tuesday, February 18, 2020 3:52 PM

Page 56: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 16

ESPECIFICACIONESRango de temperatura ambiente de funcionamiento:

Compresor: De -40 a +155 °F (-40 a +68 °C)Caldera: De 30 a +130 ºF (-1 a +54 ºC)

Rango de humedad relativa de funcionamiento: 0 - 99 %

Características eléctricas:24 V CA, 50/60 Hz.

Dimensiones:175 mm x 168 mm x 38 mm

Habilitación inalámbrica mediante la tecnología RedLink™.

Fig. 15. Dimensiones.

M35664

6-7/8 (175)

6-39/64(168)

1-31/64(38)

33-00135EFS_E.book Page 16 Tuesday, February 18, 2020 3:52 PM

Page 57: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

17 33-00135EFS—09

PARTES SEPARABLESERM con TH8321R1001/U: YERM5220R8321ERM con TH8321R1001/U y THM5421R1021: YERM5220RVPEIM

REGULACIONES DE LA FCC§ 15.19 (A)(3)Este dispositivo cumple con la Sección 15 de las regulaciones la FCC. El funcionamiento está sujeto a las dos condiciones siguientes:

1. Este dispositivo no debe causar interferencia perjudicial y2. este dispositivo deberá aceptar cualquier interferencia que se

reciba, incluyendo la interferencia que pudiese causar el funcionamiento no deseado.

REGULACIONES ICRSS-GENEste dispositivo cumple con la(s) norma(s) RSS exentas de licencia de la industria de Canadá. El funcionamiento está sujeto a las dos condiciones siguientes:

1. Este dispositivo no debe causar interferencia, y2. Este dispositivo deberá aceptar cualquier interferencia, incluso

la interferencia que pudiese causar el funcionamiento no deseado del dispositivo.

33-00135EFS_E.book Page 17 Tuesday, February 18, 2020 3:52 PM

Page 58: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

33-00135EFS—09 18

ADVERTENCIA DE LA FCC(§15.21) (SOLO EN LOS EE.UU.)Los cambios o las modificaciones que no hayan sido expresamente aprobados por la parte responsable del cumplimiento de las regulaciones podrían anular la autoridad del usuario para hacer funcionar el equipo.

33-00135EFS_E.book Page 18 Tuesday, February 18, 2020 3:52 PM

Page 59: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

19 33-00135EFS—09

GARANTÍA DE 5 AÑOSResideo garantiza que este producto, excluyendo la batería, no tiene defectos en la mano de obra ni en los materiales en condiciones de uso y servicio normales durante un período de cinco (5) años desde la fecha de compra por parte del comprador original. Si en cualquier momento, durante el período de vigencia de la garantía, se determina que el producto está defectuoso debido a la mano de obra o los materiales, Resideo lo reparará o reemplazará (a elección de Resideo).

Si el producto está defectuoso(i) devuélvalo, con una factura de venta o cualquier otro comprobante de compra con fecha, al lugar donde lo compró; o(ii) llame al Servicio de atención al cliente de Resideo al 1-800-633-3991. En el Servicio de atención al cliente determinarán si el producto debe ser devuelto a la siguiente dirección: Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, o si se le puede enviar un producto de reemplazo.

Esta garantía no cubre los gastos de remoción ni de reinstalación. Esta garantía no se aplicará si Resideo demuestra que el defecto fue causado por daños que se produjeron mientras el producto estuvo en posesión de un consumidor.

La única responsabilidad de Resideo será la de reparar o reemplazar el producto según los términos mencionados anteriormente. RESIDEO NO SERÁ RESPONSABLE POR LA PÉRDIDA O EL DAÑO DE NINGÚN TIPO, INCLUYENDO LOS DAÑOS ACCIDENTALES O RESULTANTES DERIVADOS DIRECTA O INDIRECTAMENTE DEL INCUMPLIMIENTO DE LAS GARANTÍAS, EXPRESAS O IMPLÍCITAS, O DE OTRAS FALLAS DE ESTE PRODUCTO. Algunos estados no permiten la exclusión o limitación de los daños accidentales o resultantes, por lo que esta limitación podría no aplicarse en su caso.

ESTA GARANTÍA ES LA ÚNICA GARANTÍA EXPRESA QUE RESIDEO OTORGA SOBRE ESTE PRODUCTO. LA DURACIÓN DE CUALQUIERA DE LAS GARANTÍAS IMPLÍCITAS, INCLUIDAS LAS GARANTÍAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN DETERMINADO, QUEDA, POR EL PRESENTE, LIMITADA A LA DURACIÓN DE CINCO AÑOS DE ESTA GARANTÍA. Algunos estados no permiten limitaciones en relación a la duración de una garantía implícita, de manera que la limitación anterior puede no aplicarse en su caso.

Esta garantía le otorga derechos legales específicos, pero es posible que usted goce de otros derechos que varían de un estado a otro. Si tiene preguntas acerca de esta garantía, escriba a Resideo Customer Relations, 1985 Douglas Dr. Golden Valley, MN 55422 o llame al 1-800-633-3991.

33-00135EFS_E.book Page 19 Tuesday, February 18, 2020 3:52 PM

Page 60: 33-00135EFS E.book Page 1 Tuesday, February 18, 2020 3:52 ... · 5 33-00135efs—09 fig. 3. terminal designations for boiler. m35656a j r c y o/b t d l s1 s1 terminal designations

© 2020 Resideo Technologies, Inc. All rights reserved.The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manufactured by Resideo Technologies, Inc. and its affiliates.Tous droits réservés. La marque de commerce Honeywell Home est utilisée avec l’autorisation d’Honeywell International, Inc. Ce produit est fabriqué par Resideo Technologies, Inc. et ses sociétés affiliées.Todos los derechos reservados. La marca comercial Honeywell Home se utiliza bajo licencia de Honeywell International, Inc. Este producto es fabricado por Resideo Technologies, Inc. y sus afiliados.

www.resideo.com

Resideo Technologies, Inc.1985 Douglas Drive North, Golden Valley, MN 554221-800-468-150233-00135EFS—09 M.S. Rev. 02-20 | Impreso en EE. UU.

33-00135EFS_E.book Page 20 Tuesday, February 18, 2020 3:52 PM