30529 East Mill Run Milton, Delaware 19968
description
Transcript of 30529 East Mill Run Milton, Delaware 19968
30529 East Mill RunMilton, Delaware 19968
302-644-1435Fax 302-644-1437
Bruce R. Moore
ComCor Tech ~ HistoryComCor Tech ~ History
Organization formed in 1987Organization formed in 1987– Primary business was coating salesPrimary business was coating sales
Owners such as MOC, Crowley and MTL Owners such as MOC, Crowley and MTL requested our services in coating applicationrequested our services in coating application
Started with soft coatings such as Started with soft coatings such as Magnakote and BiokoteMagnakote and Biokote
Coating market progressed to the Coating market progressed to the development of surface tolerant epoxies.development of surface tolerant epoxies.
ComCor Tech ~ What We Do!ComCor Tech ~ What We Do!
Developed relationship with coating companies Developed relationship with coating companies such as Jotun, International, Devoe, Sigma, such as Jotun, International, Devoe, Sigma, Sherwin Williams and Royal ChemicalSherwin Williams and Royal Chemical
Present systems are mostly 100% solid coatings.Present systems are mostly 100% solid coatings. We utilize both electric and diesel blasting We utilize both electric and diesel blasting
systems.systems. Owners asked us to prepare surfaces utilizing Owners asked us to prepare surfaces utilizing
water and slurry blasting.water and slurry blasting. We found German technology to be the most We found German technology to be the most
advanced.advanced.
Surface Preparation AlternativesSurface Preparation Alternatives
Slurry blasting is a Slurry blasting is a technique for preparing technique for preparing surfaces with a mixture surfaces with a mixture of fresh water and an of fresh water and an abrasive. We utilize abrasive. We utilize pressurized water to pressurized water to propel abrasives. propel abrasives. Surfaces will be to a Surfaces will be to a SA-2.5 equivalent.SA-2.5 equivalent.
Hi-Pressure water Hi-Pressure water blasting will first utilize blasting will first utilize mechanical scalers to mechanical scalers to knock off hard scale knock off hard scale areas. Surfaces are areas. Surfaces are then blasted at 500 then blasted at 500 BAR, standard will be BAR, standard will be to a WJ-2 on all to a WJ-2 on all breakdown areas.breakdown areas.
Diesel water blasting unit welded to the deck.Diesel water blasting unit welded to the deck.
WE CAN PLACE THIS EQUIPMENT ANYWHERE ON THE VESSEL TO GAIN ACCESS TO THE TANKS.
ELECTRIC BLASTERS RATED AT 500 BAR.
DIESEL BLASTERS RATED AT 12,000 PSI (35 GPM)
DIESEL BLASTERS RATED AT 12,000 PSI (35 GPM)
THE AIRLESS SPRAY PUMPS THE AIRLESS SPRAY PUMPS SHOWN ARE DESIGNED FOR SHOWN ARE DESIGNED FOR
APPLICATION OF 100% SOLID APPLICATION OF 100% SOLID EPOXIES.EPOXIES.
Horizon LinesHorizon Lines
Horizon Lines ~ Blasted SurfaceHorizon Lines ~ Blasted Surface
Horizon Lines ~ Blasted SurfaceHorizon Lines ~ Blasted Surface
Horizon Lines ~ Blasted SurfaceHorizon Lines ~ Blasted Surface
Horizon Lines ~ Blasted SurfaceHorizon Lines ~ Blasted Surface
Horizon Lines ~ Blasted SurfaceHorizon Lines ~ Blasted Surface
Horizon Lines ~ Slurry BlastedHorizon Lines ~ Slurry Blasted
Horizon Lines ~ Slurry BlastedHorizon Lines ~ Slurry Blasted
Horizon Lines ~ Prime CoatHorizon Lines ~ Prime Coat
Horizon Lines ~ Prime CoatHorizon Lines ~ Prime Coat
Horizon Lines ~ Prime CoatHorizon Lines ~ Prime Coat
Horizon Lines ~ Top CoatHorizon Lines ~ Top Coat
Horizon Lines ~ Top CoatHorizon Lines ~ Top Coat
Horizon Lines ~ Top CoatHorizon Lines ~ Top Coat
Horizon Lines ~ Top CoatHorizon Lines ~ Top Coat
Horizon Lines ~ Top CoatHorizon Lines ~ Top Coat
Horizon Lines ~ Top CoatHorizon Lines ~ Top Coat
AHL Shipping CompanyAHL Shipping Company
AHL ~ Prior to BlastingAHL ~ Prior to Blasting
AHL ~ Prior to BlastingAHL ~ Prior to Blasting
AHL ~ Prior to BlastingAHL ~ Prior to Blasting
AHL ~ Blasted SurfaceAHL ~ Blasted Surface
AHL ~ Blasted SurfaceAHL ~ Blasted Surface
AHL ~ Blasted SurfaceAHL ~ Blasted Surface
AHL ~ Coated SurfaceAHL ~ Coated Surface
AHL ~ Coated SurfaceAHL ~ Coated Surface
AHL ~ Coated SurfaceAHL ~ Coated Surface
Program ApproachProgram Approach
Use the correct equipment. A combination Use the correct equipment. A combination of pressure and flow to achieve surface of pressure and flow to achieve surface standards required.standards required.
ComCor has experience in removing oil, ComCor has experience in removing oil, mud and other contaminants efficiently prior mud and other contaminants efficiently prior to blasting.to blasting.
Electric blasters are rated for efficient Electric blasters are rated for efficient production.production.
-continued--continued-
Program ApproachProgram Approach
Triple head mechanical scalers are used Triple head mechanical scalers are used where necessary.where necessary.
Slurry blasting utilized to profile existing Slurry blasting utilized to profile existing coating systems.coating systems.
Diesel blasters equipped with nitrogen Diesel blasters equipped with nitrogen splitter utilized in shipyard and also on some splitter utilized in shipyard and also on some projects underway.projects underway.
Technical ApproachTechnical Approach
Working relationship with paint companies allows Working relationship with paint companies allows ComCor to devise paint specifications for efficient ComCor to devise paint specifications for efficient production and excellent results.production and excellent results.
Pictures supplied of prepared tanks step by step of Pictures supplied of prepared tanks step by step of the procedure.the procedure.
Infrared thermometer and relative humidity Infrared thermometer and relative humidity readings taken to ensure proper conditions for readings taken to ensure proper conditions for coating application.coating application.
Explosive gas meter and properly sized Explosive gas meter and properly sized ventillators are utilized to ensure safe working ventillators are utilized to ensure safe working environments.environments.
Four Gas & Infrared Temperature GaugesFour Gas & Infrared Temperature Gauges
Digital Temperature/ Humidity GaugeDigital Temperature/ Humidity Gauge
ComCor Tech, LLC30529 East Mill RunMilton, Delaware 19968
Thank You.
We look forward to working with you in the
near future.
302-644-1435Fax [email protected]