3 x Lithium 12.8V-100Ah Smart LiFePO4 · BMS 0.5A FUSES CCGX 1A MAIN FUSES BATTERY PRE MAIN...

1
victron energy ARGOFET Battery Isolator 40 AMPERE THERMAL CIRCUIT BREAKER 285040F Conn-G Batt+ Conn-F Batt- VE Bus mains detector Conn-G Batt+ Conn-F Batt- Conn-L Case ground Load Load Load xxxA MEGA xxxA MEGA xxxA MEGA MAIN DC COLOR CONTROL GX INVERTER/CHARGER MAIN SWITCH-1 color control Inverting AC Input AC Loads 0W 102W 75% 103W 12.8V 8.1A -90W DC Power PV-Charger 300W 0-5 m cable length: 4 x 50SQmm 5-10 m cable length: 4 x 70SQmm Cable length stands for the distance between the battery and the MultiPlus connections !!! Recommendations are without other loads in the system and these also should be taken into account for proper main battery, main fuse & main switch cables !!! Fuse size should be 1 x 400A or 2 x 200A Recommended DC cable/fuse size MultiPlus AC IN must be protected by a circuit breaker rated at 50A max or less. This depends heavily on the size of the connected power source.The input currents must be adjusted to fit the size of the connected power source. The breaker and cable size for AC IN should be adjusted accordingly. Recommended AC IN cable/breaker size MultiPlus With Power assist the MultiPlus can add 3KW to the output load when needed. Together with the adjustable 50A input this all adds up to the max sum of input and output current of 50+13=63A. An Earth leakage with breaker or a combination MCB/RCD must be installed on the output. Cable size must be adjusted accordingly. Recommended AC Out-1 cable/breaker size MultiPlus AC Out-2 only is available when power is present on AC IN-1. During battery operation it will be disconnected. AC Out-2 supports up to 16A and is adjustable. An Earth leakage with breaker or a combination MCB/RCD must be installed on the output. Cable size must be adjusted accordingly. Recommended AC Out-2 cable/breaker size MultiPlus MPPT 230 VOLT IS EXTREMELY HAZARDOUS DO NOT TOUCH ANY LIFE WIRED PARTS OF THE INSTALLATION !!! WHEN IN DOUBT, ALWAYS CONSULT YOUR VICTRON DEALER !!! WARNING Drawing BJE-256B CENTRAL NEGATIVE BUSBAR VE-BUS BMS BP220 GND DISTRIBUTION OFF ON SMART BATTERYPROTECT 220 OFF ON MultiPlus Batt + MultiPlus Batt + victron energy BLUE POWER 12.8V-100Ah Lithium Smart LiFePO4 THE BMV SHUNT IS MOUNTED DIRECT ON BOTH BUSBARS Load Load CCGX Alternator- MultiPlus Batt- MultiPlus Batt- MultiPlus Case GR victron energy BLUE POWER 12.8V-100Ah Lithium Smart LiFePO4 victron energy BLUE POWER 12.8V-100Ah Lithium Smart LiFePO4 MultiPlus 12 |3000 |120 charger inverter inverter on overload low battery temperature mains on bulk absorption float I on charger only O off .battery charger .powerassist .transfer switch .three phase .sinewave inverter .parallel connectable AC transfer capacity: 50A | Inverter 230V VOLT VA AMP www.victronenergy.com CE victron energy BLUE POWER MULTIPLUS 3KW/12V/230V AC Conn-C AC OUT-1 Conn-D AC OUT-2 Conn-A AC IN No Break load-1 No Break load-2 No Break load-3 Switched load-1 Switched load-2 Switched load-3 GENERATOR AC BREAKERS AC DISTRIBUTION FROM MULTIPLUS MAIN INCOMMING Shore Gen 0 0 OFF name 0 OFF 0 OFF name 0 OFF CHANGE OVER SWITCH AC POWER SOURCE ISOLATION TRANSFORMER OR GALVANIC ISOLATOR SHOULD BE INSERTED HERE IF NEEDED, INCLUDING NECESSARY BREAKERS. 400A MEGA ANL 175A ANL 175A ANL 175A 100A MEGA Alternator BUSBAR POSITIVE BMV-712 SMART BMS 0.5A FUSES CCGX 1A MAIN FUSES BATTERY PRE MAIN SWITCH-2 BMV 100mA 5x20mm 0 OFF name 0 OFF SmartSolar charge controller MPPT 100 | 30 Bulk Absorbtion Float BATTERY PV + - - + victron energy BLUE POWER ! i SMART MPPT PV ARRAY PV BREAKER ISOLATOR Li-DISTRIBUTION The VE-BUS BMS is enlarged visible in this drawing. The BMS GND is not connected to prevent ground loops. Ground comes through the VE-BUS UTP cable. VE bus1 VE bus2 build inside MultiPlus AC input VRM WORLD victron energy SHORE POWER CONNECTION KEEP NEGATIVE BATTERY CABLES ALL AT THE SAME LENGTH ! KEEP POSITIVE BATTERY CABLES ALL AT THE SAME LENGTH ! BUSBAR POSITIVE VE-BUS MAINS DETECTOR 12.8V-100Ah 3 x Lithium Smart LiFePO4 MULTIPLUS OUTPUT-1 MULTIPLUS OUTPUT-2 0 OFF name 0 OFF name 0 OFF name name ADxxxxx xxA/I n0.03A 0 1 N 2 N T Bx 0 OFF name 0 OFF name 0 OFF name name ADxxxxx xxA/I n0.03A 0 1 N 2 N T Bx MCB/RCD MCB/RCD The BatteryProtect must be programmed for Li-Ion mode and 24 Volt either through programming on the device itself or with a Bluetooth enabled smartphone or tablet. Connect the load disconnect output of the VE.Bus BMS to Remote H terminal. Smart BatteryProtect programming ALARM LED R POS. NEG. CYRIX LI CYRIX Li CHARGE 230 CYRIX Li CHARGE 230 B- D+ B+ Engine- FUSE IGNITION Starter Battery + ARGO FET Charge light ARGOFET BATTERY ISOLATOR MPPT- ALTERNATOR (Lithium Proof) 12V-80A Starter Battery + Maximum 5mA BMS ON/OFF SELECT SETUP BATTERY MONITOR BMV-712 SMART V victron energy

Transcript of 3 x Lithium 12.8V-100Ah Smart LiFePO4 · BMS 0.5A FUSES CCGX 1A MAIN FUSES BATTERY PRE MAIN...

Page 1: 3 x Lithium 12.8V-100Ah Smart LiFePO4 · BMS 0.5A FUSES CCGX 1A MAIN FUSES BATTERY PRE MAIN SWITCH-2 BMV 100mA 5x20mm 0 OFF name 0 OFF SmartSolarcharge controller MPPT 100 | 30 Bulk

victron energy

BLUE POWER

www.victronenergy.com

ARGOFET Battery Isolator100A 2 Output

ENERGIZE

100A 3 Output

200A 2 Output

200A 3 Output

GROUNDOUTPUT-2 OUTPUT-1 INPUT

40 A

MP

ER

E

TH

ER

MA

L C

IR

CU

IT

B

RE

AK

ER

285040F

Conn-G Batt+

Conn-F Batt-

VE Bus mains detector

Conn-G Batt+

Conn-F Batt-

Conn-L Case ground

Load

Load

Load

xxxA

MEGA

xxxA

MEGA

xxxA

MEGA

MAIN DC

COLOR CONTROL GX

INVERTER/CHARGER

MAIN SWITCH-1

color

victron energy

BLUE POWER

control

victron energy

InvertingAC Input AC Loads

0W 102W

75%

- +

103W

12.8V 8.1A

-90W

DC Power

victron energy

PV-Charger

300W

0-5 m cable length: 4 x 50SQmm

5-10 m cable length: 4 x 70SQmm

Cable length stands for the distance between the

battery and the MultiPlus connections !!!

Recommendations are without other loads in the

system and these also should be taken into

account for proper main battery, main fuse & main

switch cables !!!

Fuse size should be 1 x 400A or 2 x 200A

Recommended DC cable/fuse size MultiPlus

AC IN must be protected by a circuit

breaker rated at 50A max or less. This

depends heavily on the size of the

connected power source.The input currents

must be adjusted to fit the size of the

connected power source. The breaker and

cable size for AC IN should be adjusted

accordingly.

Recommended AC IN

cable/breaker size MultiPlus

With Power assist the MultiPlus can add

3KW to the output load when needed.

Together with the adjustable 50A input this

all adds up to the max sum of input and

output current of 50+13=63A. An Earth

leakage with breaker or a combination

MCB/RCD must be installed on the output.

Cable size must be adjusted accordingly.

Recommended AC Out-1 cable/breaker size MultiPlus

AC Out-2 only is available when power is

present on AC IN-1. During battery

operation it will be disconnected.

AC Out-2 supports up to 16A and is

adjustable. An Earth leakage with breaker

or a combination MCB/RCD must be

installed on the output. Cable size must be

adjusted accordingly.

Recommended AC Out-2 cable/breaker size MultiPlus

MPPT

230 VOLT IS EXTREMELY HAZARDOUS

DO NOT TOUCH ANY LIFE WIRED

PARTS OF THE INSTALLATION !!!

WHEN IN DOUBT, ALWAYS CONSULT

YOUR VICTRON DEALER !!!

WARNING

Drawing BJE-256B

CENTRAL NEGATIVE BUSBAR

VE-BUS BMS

BP220 GND

DISTRIBUTION

OFF

ON

SMART BATTERYPROTECT 220

OFF

ON

MultiPlus Batt +

MultiPlus Batt +

vic

tro

n en

erg

y

BL

UE

P

OW

ER

12

.8

V-1

00

Ah

LithiumS

ma

rt L

iF

eP

O4

THE BMV SHUNT IS MOUNTED

DIRECT ON BOTH BUSBARS

Load

Load

CCGX

Alternator-

MultiPlus Batt-

MultiPlus Batt-

MultiPlus Case GR

vic

tro

n en

erg

y

BL

UE

P

OW

ER

12

.8

V-1

00

Ah

LithiumS

ma

rt L

iF

eP

O4

vic

tro

n en

erg

y

BL

UE

P

OW

ER

12

.8

V-1

00

Ah

LithiumS

ma

rt L

iF

eP

O4

MultiPlus

12 |3000 |120

charger inverter

inverter on

overload

low battery

temperature

mains on

bulk

absorption

float

I on

charger only

O off

.battery charger

.powerassist

.transfer switch

.three phase

.sinewave inverter

.parallel

connectable

AC transfer capacity: 50A | Inverter 230V

VO

LT

VA

AM

P

www.victronenergy.com

CE

victron energy

BLUE POWER

Battery

AC in 1

AC in 2

AC out 1

AC out 2

MULTIPLUS 3KW/12V/230V AC

Conn-C AC OUT-1

Conn-D AC OUT-2

Conn-A AC IN

No Break load-1

No Break load-2

No Break load-3

Switched load-1

Switched load-2

Switched load-3

GENERATOR

AC BREAKERS

AC DISTRIBUTION

FROM MULTIPLUS

MAIN INCOMMING

Shore Gen

0

0 OFF

name

0 OFF 0 OFF

name

0 OFF

CHANGE OVER SWITCH

AC POWER SOURCE

ISOLATION TRANSFORMER OR

GALVANIC ISOLATOR SHOULD BE

INSERTED HERE IF NEEDED,

INCLUDING NECESSARY

BREAKERS.

400A

MEGA

ANL

175A

ANL

175A

ANL

175A

100A

MEGA

Alternator

BUSBAR

POSITIVE

BMV-712 SMART

BMS 0.5A

FUSES

CCGX 1A

MAIN FUSES

BATTERY PRE

MAIN SWITCH-2

BMV 100mA

5x20mm

0 OFF

name

0 OFF

SmartSolar charge controller

MPPT 100 | 30

Bu

lk

Ab

so

rb

tio

n

Flo

at

BATTERY PV

+ - - +

victron energy

BLUE POWER

!

i

SMART MPPT PV ARRAY

PV BREAKER

ISOLATOR

Li-DISTRIBUTION

The VE-BUS BMS is enlarged

visible in this drawing.

The BMS GND is not connected

to prevent ground loops.

Ground comes through the

VE-BUS UTP cable.

VE bus1 VE bus2

build inside MultiPlus

AC input

VRM

WORLD

victron energy

BLUE POWER

SHORE POWER

CONNECTION

KEEP NEGATIVE BATTERY CABLES

ALL AT THE SAME LENGTH !

KEEP POSITIVE BATTERY CABLES

ALL AT THE SAME LENGTH !

BUSBAR

POSITIVE

VE-BUS MAINS DETECTOR

12.8V-100Ah

3 x Lithium

Smart LiFePO4

MULTIPLUS

OUTPUT-1

MULTIPLUS

OUTPUT-2

0 OFF

name

0 OFF

name

0 OFF

namenameADxxxxx xxA/I n0.03A

test regularly

0

earth fault indicator

1 N

2 N

TBx

0 OFF

name

0 OFF

name

0 OFF

namenameADxxxxx xxA/I n0.03A

test regularly

0

earth fault indicator

1 N

2 N

TBx

MCB/RCD MCB/RCD

The BatteryProtect must be programmed

for Li-Ion mode and 24 Volt either through

programming on the device itself or with a

Bluetooth enabled smartphone or tablet.

Connect the load disconnect output of the

VE.Bus BMS to Remote H terminal.

Smart BatteryProtect programming

ALARM LED

R

POS. NEG.

CYRIX LI

CYRIX Li CHARGE 230

CYRIX Li

CHARGE

230

B-

D+

B+

Engine-

FUSE

IGNITION

Starter Battery +

ARGO FET

Charge light

ARGOFET BATTERY ISOLATOR

MPPT-

ALTERNATOR

(Lithium Proof)

12V-80A

Starter Battery +

Maximum 5mA

BMS ON/OFF

SELECTSETUP

BATTERY MONITOR

BMV-712 SMART

V

victron energy

BLUE POWER

MAIN

AutoCAD SHX Text
BTV CABLE
AutoCAD SHX Text
RESET
AutoCAD SHX Text
BAT
AutoCAD SHX Text
LOAD
AutoCAD SHX Text
V+
AutoCAD SHX Text
GND
AutoCAD SHX Text
VE BUS
AutoCAD SHX Text
ETHERNET
AutoCAD SHX Text
SUPPLIED UTP CABLE
AutoCAD SHX Text
VE-direct
AutoCAD SHX Text
BMV POWER +
AutoCAD SHX Text
CCGX POWER +
AutoCAD SHX Text
VE-direct
AutoCAD SHX Text
12/24V | 30A
AutoCAD SHX Text
Battery |
AutoCAD SHX Text
100V | 30A
AutoCAD SHX Text
PV |
AutoCAD SHX Text
max
AutoCAD SHX Text
IP43
AutoCAD SHX Text
BTV CABLE
AutoCAD SHX Text
BTV CABLE
AutoCAD SHX Text
BTV CABLE
AutoCAD SHX Text
BTV CABLE
AutoCAD SHX Text
BTV CABLE
AutoCAD SHX Text
TO BMS
AutoCAD SHX Text
FROM BMS
AutoCAD SHX Text
VE-BUS MAINS DETECTOR
AutoCAD SHX Text
CCGX VE-BUS CONNECTION
AutoCAD SHX Text
VE-direct-1
AutoCAD SHX Text
SHORE POWER
AutoCAD SHX Text
BMS POWER+
AutoCAD SHX Text
BMS LOAD DISCONNECT
AutoCAD SHX Text
BMS CHARGE DISCONNECT
AutoCAD SHX Text
ALARM LED +
AutoCAD SHX Text
ALARM LED -
AutoCAD SHX Text
VE-direct-2
AutoCAD SHX Text
FROM MPPT
AutoCAD SHX Text
xx AMP.
AutoCAD SHX Text
30
AutoCAD SHX Text
AC
AutoCAD SHX Text
FROM ENGINE+(30)
AutoCAD SHX Text
ENGINE SYSTEM
AutoCAD SHX Text
+B1
AutoCAD SHX Text
+B2