3-phase Motors - 1 Rotating Magnetic Field

Transcript of 3 phase motors 1

Page 1: 3 phase motors 1

3-phase Motors - 1

Rotating Magnetic Field

Page 2: 3 phase motors 1

3-phase Supply

(3 voltages, 120o apart)

3-phase Motor Stator

(3 Windings, 120o apart)Phase A (Red)

Phase B (Black)Phase C (Blue)

Arrows show Magnetic Fluxwhen phase voltage is POSITIVE

A B C

Page 3: 3 phase motors 1

3-phase Motor Stator

(3 Windings, 120o apart)

Each step is shownhere at 0.5 seconds(6 seconds per cycle)

Green dotted lines show resulting magnet flux

Green arrow shows flux direction

Three-phase sequence produces resulting ROTATINGMAGNETICFLUX

Page 4: 3 phase motors 1

3-phase Motor Stator

(3 Windings, 120o apart)

Each step is shownhere at 0.2 seconds(2.4 seconds per cycle)

Page 5: 3 phase motors 1

3-phase Motor Stator

(3 Windings, 120o apart)

Each step is shownhere at 0.1 seconds(1.2 seconds per cycle)

Page 6: 3 phase motors 1

3-phase Motor Stator

(3 Windings, 120o apart)

This shows continuous1 second per cycle

Page 7: 3 phase motors 1

3-phase Motor Stator

(3 Windings, 120o apart)

The STATOR core is a stack of thin silicon steel LAMINATIONS

Page 8: 3 phase motors 1

3-phase Motor Stator

(3 Windings, 120o apart)

Windings are coils placed in SLOTS around the STATOR

The coils are connected in groups for each of the THREE PHASES

Page 9: 3 phase motors 1

Speed – Frequency - Poles

The SPEED of the rotating magnetic fieldis determined by:

Supply FREQUENCY in Hertz (Hz)

Number of magnetic POLESproduced by the stator windings

Page 10: 3 phase motors 1

Speed – Frequency - PolesThe SPEED of the rotating magnetic field is determined by:

120Synch

fN

P

SynchronousSpeed (rpm)

Frequency(Hz)

Number of Polesper phase

x2 Poles to PAIRSx60 rps to rpm

Page 11: 3 phase motors 1

Production of Torque

Page 12: 3 phase motors 1

Production of Torque

Note that the ROTOR LAGS behind the rotating magnetic field

(Watch the pink dot)