Okoguard-Okolon TS-CPE is Okonite’s tradename for its composite insulation systemconsisting of a layer of EPR and coveredwith a chlorinated polyethylene (CPE)thermoset compound.
The advantages of Okoguard EPR, with aproven track record of over 40 years as amedium voltage insulation, are now offeredin low voltage cables. Okolon TS-CPE isOkonite's trade name for its chlorinated poly-ethylene (CPE) thermoset compound.
Okoguard-Okolon TS-CPE 600 Volt Powerand Control Cables are recommended foruse in all low voltage circuits where continu-ity of service is the prime consideration.These cables may be installed in wet or drylocations, indoors or outdoors, in raceways,underground ducts, directly buried in theearth, or lashed to a messenger for aerial in-stallation. These cables may also be in-stalled in cable tray (size 1/0 AWG and largerper NEC 392.2).
Uncoated soft copper per ASTMB-3. Solid per ASTM B-3. Sizes smaller than#8 are compress stranded per ASTM B-8.Sizes #8 and larger are compact strandedper ASTM B-496.
Meets or exceeds all require-ments of ICEA S-95-658, NEMA WC-70 andUL Standards 44 and 854.
Listed by Underwriters Laboratories, Inc. asType RHH or RHW-2 or USE-2, VW-1. Sizes1/0 AWG and larger are also marked sunlightresistant, for use in cable tray.
Listed by CSA as RW-90, -40C, FT1 (1/0and larger: FT4), sunlight resistant.
• Sizes 1/0 AWG and larger pass the Ver-tical Tray Flame Test requirements of UL1581 for use in cable tray.
• Passes the IEEE 383 Vertical TrayFlame Test. (sizes #6 AWG and larger)
• Passes the IEEE 1202 Vertical TrayFlame Test. (sizes 1/0 AWG & larger)
• Extreme heat resistance;90°C continuous rating, wet or dry130°C emergency overload rating250°C short circuit rating
• Exceptional resistance to deformationat high temperature.
• Stable electrical properties.
• Low SIC and power factor.
• Low moisture absorption.
• Mechanically rugged.
• Resistant to weather, most oils, acidsand alkalies.
• More flexible, easier to install and termi-nate than XLPE insulation.
• UL and CSA Listed.
Okoguard-Okolon® TS-CPE Type RHHor RHW-2 or USE-2, VW-1, FT-4, CSA RW-90
Copper Conductor/90°C Wet or Dry
Uncoated, Copper ConductorComposite Okoguard/OkolonTS-CPE Insulation
14-9 30 15
8 45 15
6-2 45 30
1-4/0 55 45
250-500 65 65
750-1000 80 65
ULR
B
A
OK
ON
ITE
51/
0A
WG
CU
OK
OG
UA
RD
EP
TS
-CP
E(U
L)
![Page 2: 3-1](https://reader030.fdocuments.us/reader030/viewer/2022013109/577ccef71a28ab9e788e877c/html5/thumbnails/2.jpg)
112-24-2061� 112-24-2071
112-24-2091
141412
171
454545
1.141.141.14
0.160.170.18
4.064.574.57
232532
283037
151520
151520
242430
� 112-24-2101112-24-2121
� 112-24-2131
121010
717
454545
1.141.141.14
0.190.200.21
4.835.085.33
344649
395154
203030
203030
304242
112-24-2171� 112-24-2191� 112-24-2221
986
1977
456075
1.141.521.91
0.230.270.33
5.846.868.38
5875
119
6382
130
305575
305065
485575
� 112-24-2251� 112-24-2311
112-24-2331
421
77
19
7575
100
1.911.912.54
0.380.430.52
9.7511.0013.16
173257340
184280372
95130150
85115130
97130156
� 112-24-2351� 112-24-2371
112-24-2391
1/02/03/0
191919
100100100
2.542.542.54
0.560.600.64
14.1015.1416.33
414507622
446539654
170195225
150175200
179204242
� 112-24-2411� 112-24-2431� 112-24-2471
4/0250350
193737
100130130
2.543.303.30
0.700.800.89
17.6820.3222.61
766938
1265
805993
1320
260290350
230255310
278317384
� 112-24-2531� 112-24-2591� 112-24-2651
500750
1000
376161
130145145
3.303.683.68
1.011.211.36
25.6530.7334.54
175025903391
182726903568
430535615
380475545
477598689
Visit Okonite's web site, www.okonite.com, for the most up to date dimensions.
� Available from our Customer Service Centers. are based on Table 310.16 of the National Electrical Code forthese 90°C rated conductors at an ambient temperature of 30°C. The 75°Cwet column is provided for additional information.
The ampacities shown apply to open runs of cable, installation in any approvedraceway, direct burial in the earth, or as aerial cable on a messenger. Deratingfor more than three current carrying conductors within a raceway is in accor-dance with NEC Sectiion 310.15.B.2.
Based on three (3) conductors in a single enclosed or exposed conduit. Ca-pacities based on 40°C air ambient using ICEA methods. For 30°C ambientmultiply values by 1.10; for 50°C multiply by .90. For other ambients or installa-tion conditions refer to Engineering Data Book EHB.
For ampacities in cable tray, see NEC Section 392.11.B.
B\11100301
Okoguard-Okolon TS-CPE Type RHH orRHW-2 or USE-2, VW-1, FT-4, CSA RW-90Copper Conductor/90°C Wet or Dry
To order a color other than black, change the last digit of thecatalog number as follows:
White 2 Orange 5
Red 3 Blue 6
Green 4 Yellow 7
Example: To order #14/Sol - Red, the catalog number would be112-24-2063.
ULR
Ramsey, New Jersey 07446THE OKONITE COMPANY