Nokia Siemens Networks
GSM/EDGE BSS, Rel.
RG20(BSS), OperatingDocumentation, Issue 03
Reference
Transmission Equipment Alarms (8000-
8999)
DN998797
Issue 8-1
Approval Date 2010-10-15
Confidential
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 2/486
2 DN998797
Issue 8-1
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804cd6
Confidential
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2010. All rights reserved
f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources
of danger.
Only trained and qualified personnel may install, operate, maintain or otherwise handle
this product and only after having carefully read the safety information applicable to this
product.
The safety information is provided in the Safety Information section in the “Legal, Safety
and Environmental Information” part of this document or documentation set.
The same text in German:
f Wichtiger Hinweis zur ProduktsicherheitVon diesem Produkt können Gefahren durch Laser, Elektrizität, Hitzeentwicklung oder
andere Gefahrenquellen ausgehen.
Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch
geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-
anforderungen erfolgen.
Die Sicherheitsanforderungen finden Sie unter „Sicherheitshinweise“ im Teil „Legal,
Safety and Environmental Information“ dieses Dokuments oder dieses Dokumentations-
satzes.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 3/486
DN998797 3
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804cd6
Confidential
Table of contentsThis document has 487 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1 List of Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2 Transmission equipment parameters (DX 200 Alarm System). . . . . . . 18
3 Transmission equipment parameters (BTS Alarm System) . . . . . . . . . 23
4 8000 POWER SUPPLY FAULT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
5 8001 TOTAL LOSS OF POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . 30
6 8002 LOSS OF BACK UP POWER SUPPLY . . . . . . . . . . . . . . . . . . . . 32
7 8003 LOSS OF REMOTE POWER SUPPLY . . . . . . . . . . . . . . . . . . . . 34
8 8004 UNBALANCE IN REMOTE POWER SUPPLY . . . . . . . . . . . . . . . 36
9 8005 INCORRECT RINGING VOLTAGE . . . . . . . . . . . . . . . . . . . . . . . 38
10 8006 FAULT IN CENTRAL BATTERY. . . . . . . . . . . . . . . . . . . . . . . . . . 40
11 8007 FAULT IN CRITERIA VOLTAGE . . . . . . . . . . . . . . . . . . . . . . . . . 42
12 8008 LOW BATTERY VOLTAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
13 8009 FAULT IN CURRENT LOOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
14 8010 SUPPLY UNIT VOLTAGE INCORRECT . . . . . . . . . . . . . . . . . . . 48
15 8011 DISTRIBUTION FUSE FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
16 8012 SIGNALLING VOLTAGE FAULT . . . . . . . . . . . . . . . . . . . . . . . . . 52
17 8013 CHARGER FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
18 8014 AC INPUT VOLTAGE FAILURE. . . . . . . . . . . . . . . . . . . . . . . . . . 56
19 8016 MAIN FUNCTION INHIBITED. . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
20 8017 SIGNAL LOOPED TO TERMINAL . . . . . . . . . . . . . . . . . . . . . . . . 60
21 8018 SIGNAL IS LOOPED TO TRANSMISSION PATH . . . . . . . . . . . . 62
22 8019 FUNCTION INHIBITED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6423 8020 BLOCKED FROM USE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
24 8021 LOOP TO INTERFACE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
25 8022 LOOP TO EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
26 8023 TEST MODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
27 8024 LOOP IN EQUIPMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
28 8025 TEST GENERATOR ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
29 8026 EXTERNAL TEST MODE ACTIVE. . . . . . . . . . . . . . . . . . . . . . . . 78
30 8027 BLOCKED FROM FAR END . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 4/486
4 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804cd6
Confidential
31 8028 TIMESLOT RESERVED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
32 8032 LOSS OF OUTGOING SIGNAL. . . . . . . . . . . . . . . . . . . . . . . . . . . 84
33 8033 LOSS OF OUTGOING 64K SIGNAL . . . . . . . . . . . . . . . . . . . . . . . 86
34 8034 LOSS OF OUTGOING 2M SIGNAL. . . . . . . . . . . . . . . . . . . . . . . . 88
35 8035 LOSS OF OUTGOING 8M SIGNAL. . . . . . . . . . . . . . . . . . . . . . . . 90
36 8036 LOSS OF OUTGOING 34M SIGNAL. . . . . . . . . . . . . . . . . . . . . . . 92
37 8037 LOSS OF OUTGOING 140M SIGNAL. . . . . . . . . . . . . . . . . . . . . . 94
38 8038 LOSS OF OUTGOING 560M SIGNAL. . . . . . . . . . . . . . . . . . . . . . 96
39 8039 LOSS OF OUTGOING 0.7M SIGNAL . . . . . . . . . . . . . . . . . . . . . . 98
40 8040 NO FREE CHANNEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
41 8042 LOSS OF OUTGOING TRANSMISSION PATH SIGNAL . . . . . . 102
42 8043 INCORRECT OUTGOING SIGNAL LEVEL. . . . . . . . . . . . . . . . . 104
43 8044 HIGH REFLECTED POWER. . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
44 8045 NO OUTGOING SIGNAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
45 8046 NO OUTGOING LINE SIGNAL . . . . . . . . . . . . . . . . . . . . . . . . . . 110
46 8047 PAYLOAD MISMATCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
47 8048 LOSS OF INCOMING SIGNAL . . . . . . . . . . . . . . . . . . . . . . . . . . 114
48 8049 LOSS OF INCOMING 64K SIGNAL . . . . . . . . . . . . . . . . . . . . . . 116
49 8050 LOSS OF INCOMING 2M SIGNAL . . . . . . . . . . . . . . . . . . . . . . . 118
50 8051 LOSS OF INCOMING 8M SIGNAL . . . . . . . . . . . . . . . . . . . . . . . 120
51 8052 LOSS OF INCOMING 34M SIGNAL . . . . . . . . . . . . . . . . . . . . . . 122
52 8053 LOSS OF INCOMING 140M SIGNAL . . . . . . . . . . . . . . . . . . . . . 124
53 8054 LOSS OF INCOMING 560M SIGNAL . . . . . . . . . . . . . . . . . . . . . 126
54 8055 LOSS OF INCOMING 0.7M SIGNAL. . . . . . . . . . . . . . . . . . . . . . 128
55 8056 LOSS OF INCOMING 1.5M SIGNAL. . . . . . . . . . . . . . . . . . . . . . 130
56 8057 LOSS OF POINTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
57 8058 LOSS OF INCOMING TRANSMISSION PATH SIGNAL. . . . . . . 134
58 8059 INCORRECT INCOMING SIGNAL LEVEL . . . . . . . . . . . . . . . . . 136
59 8060 NO INCOMING RADIO SIGNAL . . . . . . . . . . . . . . . . . . . . . . . . . 138
60 8061 LOSS OF INCOMING LINE SIGNAL. . . . . . . . . . . . . . . . . . . . . . 140
61 8062 NO CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142
62 8063 NO REDUNDANT CONNECTION. . . . . . . . . . . . . . . . . . . . . . . . 144
63 8064 ALARM SIGNAL (AIS) IS RECEIVED . . . . . . . . . . . . . . . . . . . . . 146
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 5/486
DN998797 5
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804cd6
Confidential
64 8065 ALARM SIGNAL (AIS 64K) IS RECEIVED. . . . . . . . . . . . . . . . . 148
65 8066 ALARM INDICATION SIGNAL (AIS) RECEIVED. . . . . . . . . . . . 150
66 8067 ALARM SIGNAL (AIS 8M) IS RECEIVED . . . . . . . . . . . . . . . . . 152
67 8068 ALARM SIGNAL (AIS 34M) IS RECEIVED . . . . . . . . . . . . . . . . 154
68 8069 ALARM SIGNAL (AIS 140M) IS RECEIVED . . . . . . . . . . . . . . . 156
69 8070 ALARM SIGNAL (AIS 560M) IS RECEIVED . . . . . . . . . . . . . . . 158
70 8071 ALARM SIGNAL (AIS 0.7M) IS RECEIVED . . . . . . . . . . . . . . . . 160
71 8072 ALARM SIGNAL (AIS 16K) IS RECEIVED. . . . . . . . . . . . . . . . . 162
72 8073 ALARM INDICATION SIGNAL (AIS) RECEIVED. . . . . . . . . . . . 164
73 8074 ALARM INDICATION SIGNAL RECEIVED ON TIMESLOT 16 . 166
74 8075 S ALARM RECEIVED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
75 8076 GENERAL ALARM IN NETWORK RECEIVED . . . . . . . . . . . . . 170
76 8077 LOOPED SIGNAL RECEIVED . . . . . . . . . . . . . . . . . . . . . . . . . . 172
77 8078 MEASUREMENT SIGNAL RECEIVED . . . . . . . . . . . . . . . . . . . 174
78 8079 TS16 CODE ERROR RECEIVED. . . . . . . . . . . . . . . . . . . . . . . . 176
79 8080 FRAME ERROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178
80 8081 LOSS OF FRAME ALIGNMENT. . . . . . . . . . . . . . . . . . . . . . . . . 180
81 8082 MULTIFRAME ALIGNMENT LOST . . . . . . . . . . . . . . . . . . . . . . 182
82 8083 LOSS OF FRAME ALIGNMENT OF SUBSYSTEM . . . . . . . . . . 184
83 8084 LOSS OF LINE FRAME ALIGNMENT . . . . . . . . . . . . . . . . . . . . 186
84 8085 LOSS OF RADIO FRAME ALIGNMENT . . . . . . . . . . . . . . . . . . 188
85 8086 LOSS OF CRC MULTIFRAME ALIGNMENT. . . . . . . . . . . . . . . 190
86 8087 LOSS OF OCTET TIMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
87 8088 END TO END FRAME LOSS . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
88 8089 LOSS OF SIGNALLING FRAME . . . . . . . . . . . . . . . . . . . . . . . . 196
89 8096 EXCESSIVE ERROR RATE. . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
90 8097 BIT ERROR RATIO (BER) > 1E-1 . . . . . . . . . . . . . . . . . . . . . . . 200
91 8098 BIT ERROR RATIO (BER) > 1E-2 . . . . . . . . . . . . . . . . . . . . . . . 202
92 8099 RECEIVED BIT ERROR RATIO (BER) > 1E-3 . . . . . . . . . . . . . 204
93 8100 RECEIVED BIT ERROR RATIO (BER) > 1E-4 . . . . . . . . . . . . . 206
94 8101 RECEIVED BIT ERROR RATIO (BER) > 1E-5 . . . . . . . . . . . . . 208
95 8102 RECEIVED BIT ERROR RATIO (BER) > 1E-6 . . . . . . . . . . . . . 210
96 8103 BIT ERROR RATIO (BER) > 1E-7 . . . . . . . . . . . . . . . . . . . . . . . 212
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 6/486
6 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804cd6
Confidential
97 8104 BIT ERROR RATIO (BER) > 1E-8. . . . . . . . . . . . . . . . . . . . . . . . 214
98 8105 BIT ERROR RATIO (BER) > 1E-9. . . . . . . . . . . . . . . . . . . . . . . . 216
99 8106 BIT ERROR RATIO (BER) > 1E-10. . . . . . . . . . . . . . . . . . . . . . . 218
100 8107 BIT ERROR RATIO (BER) > 1E-11. . . . . . . . . . . . . . . . . . . . . . . 220
101 8108 BIT ERROR RATIO (BER) > 1E-12. . . . . . . . . . . . . . . . . . . . . . . 222
102 8109 FADING IN TRANSMISSION PATH . . . . . . . . . . . . . . . . . . . . . . 224
103 8110 SELECTIVE FADING IN TRANSMISSION PATH. . . . . . . . . . . . 226
104 8111 MODULATION ERROR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228
105 8112 FREQUENCY ERROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
106 8113 BUFFER OVERFLOW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 232
107 8119 SYNCHRONIZING FAULT IN TRANSMITTER . . . . . . . . . . . . . . 234
108 8120 SYNCHRONIZING FAULT IN RECEIVER . . . . . . . . . . . . . . . . . 236
109 8121 SYNCHRONIZING FAULT IN AUXILIARY CHANNEL . . . . . . . . 238
110 8122 SYNCHRONIZING FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240
111 8123 SYNCHRONIZING FAULT IN CARRIER RECOVERY . . . . . . . . 242
112 8124 SYNCHRONIZATION FAULT IN CLOCK RECOVERY. . . . . . . . 244
113 8125 LOSS OF SYNCHRONIZATION SIGNAL . . . . . . . . . . . . . . . . . . 246
114 8126 UNIT FUNCTION DEGRADED . . . . . . . . . . . . . . . . . . . . . . . . . . 248
115 8127 EQUIPMENT FAULT DETECTED IN AUTOMATIC LOOP TEST250
116 8128 FAULT IN EQUIPMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
117 8129 FAULT IN CODEC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
118 8130 FAULT IN MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
119 8131 INTERNAL BUS FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
120 8132 FAULT IN SUMMING UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
121 8133 FAULT IN MUX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
122 8134 EXCHANGE LINE ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
123 8135 EQUIPMENT IN RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
124 8136 AIS OSCILLATOR FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
125 8137 OSCILLATOR FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270
126 8138 PRESSURE ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
127 8139 SUBRACK HAS MISSING UNITS. . . . . . . . . . . . . . . . . . . . . . . . 274
128 8140 SUBRACK HAS EXCESSIVE UNITS . . . . . . . . . . . . . . . . . . . . . 276
129 8141 FORCED CONTROL ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 7/486
DN998797 7
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804cd6
Confidential
130 8142 INSTALLATION ERROR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
131 8143 FAULT IN CHANGE OVER FUNCTION. . . . . . . . . . . . . . . . . . . 282
132 8144 OPERATING ERROR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
133 8145 TEMPERATURE ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286
134 8146 WIND ALARM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
135 8147 LOCAL ALARM CANCEL WITHOUT ANY ALARM . . . . . . . . . . 290
136 8148 EQUIPMENT RESET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292
137 8149 FORCED INDICATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294
138 8150 FAULT IN UNIT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
139 8151 FAULT IN CHANNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298
140 8152 FAULT IN BLOCK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300
141 8153 FAULT IN TRANSMITTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
142 8154 FAULT IN RECEIVER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304
143 8155 LASER BIAS OUT OF RANGE. . . . . . . . . . . . . . . . . . . . . . . . . . 306
144 8156 LASER POWER OUT OF RANGE . . . . . . . . . . . . . . . . . . . . . . . 308
145 8157 LASER TEMPERATURE OUT OF RANGE . . . . . . . . . . . . . . . . 310
146 8158 FORCED LASER CUT OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
147 8159 RUN DIAGNOSTICS TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
148 8160 INTERFACE UNIT FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
149 8161 CONNECTED TO REDUNDANT SYSTEM . . . . . . . . . . . . . . . . 318
150 8162 DATABASE FULL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 320
151 8163 REDUNDANT CONNECTION IN USE . . . . . . . . . . . . . . . . . . . . 322
152 8164 LINE CABLE FAULT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324
153 8165 REAL TIME LOST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326
154 8166 E1 CONVERTER RESET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
155 8167 E1 CONVERTER FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330
156 8168 EQUIPMENT DOOR OPEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332
157 8169 EXTENDED FAULT CODE IN USE . . . . . . . . . . . . . . . . . . . . . . 334
158 8172 YELLOW ALARM OCCURRED . . . . . . . . . . . . . . . . . . . . . . . . . 336
159 8173 FAR-END ALARM 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338
160 8174 FAR-END ALARM 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340
161 8175 FAR-END ALARM 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 342
162 8176 FAR-END ALARM RECEIVED . . . . . . . . . . . . . . . . . . . . . . . . . . 344
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 8/486
8 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804cd6
Confidential
163 8178 MULTIFRAME ALARM FROM FAR-END . . . . . . . . . . . . . . . . . . 346
164 8179 FAR-END ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348
165 8180 ALARM FROM FAR-END SUBSYSTEM. . . . . . . . . . . . . . . . . . . 350
166 8181 FAR-END SENDING FAULT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352
167 8182 FAULT IN FAR-END RECEIVING . . . . . . . . . . . . . . . . . . . . . . . . 354
168 8183 FAR-END SYNCHRONIZATION ALARM . . . . . . . . . . . . . . . . . . 356
169 8184 REAL TIME UPDATED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358
170 8185 CONNECTION OR SETTINGS HAVE CHANGED . . . . . . . . . . . 360
171 8186 CONFIGURATION ERROR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
172 8190 CUSTOMER SPECIFIC FAULT CODE 1 . . . . . . . . . . . . . . . . . . 364
173 8191 CUSTOMER SPECIFIC FAULT CODE 2 . . . . . . . . . . . . . . . . . . 366
174 8192 CUSTOMER SPECIFIC FAULT CODE 3 . . . . . . . . . . . . . . . . . . 368
175 8193 CUSTOMER SPECIFIC FAULT CODE 4 . . . . . . . . . . . . . . . . . . 370
176 8194 CUSTOMER SPECIFIC FAULT CODE 5 . . . . . . . . . . . . . . . . . . 372
177 8195 V5 PROTOCOL ALARM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
178 8200 LOSS OF PRIMARY SUPERVISION CONNECTION . . . . . . . . . 376
179 8201 LOSS OF SECONDARY SUPERVISION CONNECTION. . . . . . 378
180 8202 LOSS OF SUPERVISION CONNECTION. . . . . . . . . . . . . . . . . . 380
181 8203 LOSS OF SUPERVISION BUS . . . . . . . . . . . . . . . . . . . . . . . . . . 382
182 8206 CONGESTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
183 8207 CALIBRATION EXPIRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 386
184 8213 REMOTE DEFECT INDICATION (RDI). . . . . . . . . . . . . . . . . . . . 388
185 8214 SIGNAL DEGRADED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 390
186 8215 TRACE IDENTIFIER MISMATCH . . . . . . . . . . . . . . . . . . . . . . . . 392
187 8216 UNEQUIPPED SIGNAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 394
188 8221 VERSION MISMATCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396
189 8222 CORRUPT DATA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 398
190 8223 PROTECTION SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 400
191 8230 THRESHOLD CROSSED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 402
192 8240 ACTIVE ALARM POINT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404
193 8241 UPPER ALARM LIMIT EXCEEDED . . . . . . . . . . . . . . . . . . . . . . 406
194 8242 LOWER ALARM LIMIT EXCEEDED . . . . . . . . . . . . . . . . . . . . . . 408
195 8250 INVALID TIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 9/486
DN998797 9
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804cd6
Confidential
196 8254 OPERATOR DISABLED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412
197 8256 15 MIN G826 ES THRESHOLD CROSSED. . . . . . . . . . . . . . . . 414
198 8257 15 MIN G826 SES THRESHOLD CROSSED . . . . . . . . . . . . . . 416
199 8258 15 MIN G826 BBE THRESHOLD CROSSED . . . . . . . . . . . . . . 418
200 8259 24 H G826 ES THRESHOLD CROSSED. . . . . . . . . . . . . . . . . . 420
201 8260 24 H G826 SES THRESHOLD CROSSED . . . . . . . . . . . . . . . . 422
202 8261 24 H G826 BBE THRESHOLD CROSSED . . . . . . . . . . . . . . . . 424
203 8262 STATISTIC UNAVAILABILITY . . . . . . . . . . . . . . . . . . . . . . . . . . 426
204 8263 STATISTIC RESET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 428
205 8264 15 MIN T/RLTS THRESHOLD CROSSED. . . . . . . . . . . . . . . . . 430
206 8265 24 H T/RLTS THRESHOLD CROSSED. . . . . . . . . . . . . . . . . . . 432
207 8266 LICENCE KEY NOT VALID . . . . . . . . . . . . . . . . . . . . . . . . . . . . 434
208 8267 LICENCE EXPIRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436
209 8268 LICENCE WILL EXPIRE IN THE NEAR FUTURE . . . . . . . . . . . 438
210 8269 LICENCE FOR FEATURE IS NOT AVAILABLE. . . . . . . . . . . . . 440
211 8270 LICENCE FOR FEATURE HAS BEEN ACTIVATED . . . . . . . . . 442
212 8271 LICENCE FOR FEATURE HAS BEEN DEACTIVATED. . . . . . . 444
213 8272 POSITION NOT LOCKED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446
214 8273 LICENCE FOR 2G FLEXI ABIS OVER IP/ETHERNET IS NOT
AVAILABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 448
215 8274 LICENCE FOR 2G FLEXI ADDITIONAL 2 E1/T1 IS NOT AVAILABLE
450
216 8275 LICENCE FOR 2G FLEXI ABIS TRS GROOMING IS NOT AVAIL-
ABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 452
217 8276 LICENCE FOR 2G FLEXI TRS LOOP PROTECTION IS NOT AVAIL-
ABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 454
218 8277 ETHERNET PHYSICAL LINK LAYER LOST . . . . . . . . . . . . . . . 456
219 8278 PSEUDOWIRE DOWN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458
220 8279 PSEUDOWIRE PERFORMANCE DEGRADED. . . . . . . . . . . . . 460
221 8280 PSEUDOWIRE REMOTE PACKET LOSS. . . . . . . . . . . . . . . . . 462
222 8281 FAULT IN OPTICAL INTERFACE (SFP) . . . . . . . . . . . . . . . . . . 464
223 8282 PSEUDOWIRE TUNNEL DOWN . . . . . . . . . . . . . . . . . . . . . . . . 466
224 8283 LICENCE FOR IP SECURITY IS NOT AVAILABLE. . . . . . . . . . 468
225 8284 TRAFFIC SHAPING MISCONFIGURATION . . . . . . . . . . . . . . . 470
226 8285 LICENCE FOR TIMING OVER PACKET IS NOT AVAILABLE . 472
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 10/486
10 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804cd6
Confidential
227 8286 LICENCE FOR SYNCHRONOUS ETHERNET IS NOT AVAILABLE
474
228 8287 CLOCK RECOVERY IN PROGRESS . . . . . . . . . . . . . . . . . . . . . 476
229 8288 FAULT IN CONNECTION TO CLOCK MASTER . . . . . . . . . . . . 478
230 8289 SSM HAS LOST TRACEABILITY TO PRC CLOCK SOURCE . . 480
231 8290 LICENCE FOR PACKET TRS E1/T1 IS NOT AVAILABLE . . . . . 482
232 8291 PMTU BTS TO BSC LESS THAN CONFIGRUED MTU . . . . . . . 484
233 8292 PMTU BTS TO SECURITY GATEWAY LESS THAN CONFIGURED
MTU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 11/486
DN998797 11
Transmission Equipment Alarms (8000-8999) Summary of changes
Id:0900d80580804c95
Confidential
Summary of changesChanges between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.
Changes made between issues 8-1 and 8-0
Alarms 8288 and 8289 have been updated. Notes added to meaning of alarm sections.
Changes made between issues 8-0 and 7-2
New alarms
Modified alarms
Changes made between issues 7-2 and 7-1
The names of the features BSS30305: 2G Flexi Abis over IP/Ethernet, BSS30280: 2GFlexi TRS Loop Protection, BSS21129: Flexi EDGE Abis TRS Grooming, and
BSS30285: 2G Flexi Additional 2 E1,T1 IF have been modified.
Changes made between issues 7-1 and 7-0
Modified alarms
The Flexi EDGE BTS specific instructions of the following alarms have been updated:
– 8273 LICENCE FOR FLEXIEDGE ABIS OVER IP/ETHERNET IS NOT AVAILABLE
– 8274 LICENCE FOR FLEXIEDGE ADDITIONAL 2 E1/T1 IS NOT AVAILABLE
– 8275 LICENCE FOR FLEXIEDGE TRS ABIS GROOMING IS NOT AVAILABLE
– 8276 LICENCE FOR FLEXIEDGE TRS LOOP PROTECTION IS NOT AVAILABLE
8283 8286 8289 8292
8284 8287 8290
8285 8288 8291
8099 8274 8277 8281
8112 8275 8278 8282
8273 8276 8280
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 12/486
12 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
List of Alarms
1 List of Alarms8000 POWER SUPPLY FAULT
8001 TOTAL LOSS OF POWER SUPPLY8002 LOSS OF BACK UP POWER SUPPLY
8003 LOSS OF REMOTE POWER SUPPLY
8004 UNBALANCE IN REMOTE POWER SUPPLY
8005 INCORRECT RINGING VOLTAGE
8006 FAULT IN CENTRAL BATTERY
8007 FAULT IN CRITERIA VOLTAGE
8008 LOW BATTERY VOLTAGE
8009 FAULT IN CURRENT LOOP
8010 SUPPLY UNIT VOLTAGE INCORRECT
8011 DISTRIBUTION FUSE FAULT
8012 SIGNALLING VOLTAGE FAULT
8013 CHARGER FAULT
8014 AC INPUT VOLTAGE FAILURE
8016 MAIN FUNCTION INHIBITED
8017 SIGNAL LOOPED TO TERMINAL
8018 SIGNAL IS LOOPED TO TRANSMISSION PATH
8019 FUNCTION INHIBITED
8020 BLOCKED FROM USE
8021 LOOP TO INTERFACE
8022 LOOP TO EQUIPMENT
8023 TEST MODE
8024 LOOP IN EQUIPMENT
8025 TEST GENERATOR ON
8026 EXTERNAL TEST MODE ACTIVE
8027 BLOCKED FROM FAR END
8028 TIMESLOT RESERVED
8032 LOSS OF OUTGOING SIGNAL
8033 LOSS OF OUTGOING 64K SIGNAL
8034 LOSS OF OUTGOING 2M SIGNAL
8035 LOSS OF OUTGOING 8M SIGNAL
8036 LOSS OF OUTGOING 34M SIGNAL
8037 LOSS OF OUTGOING 140M SIGNAL
8038 LOSS OF OUTGOING 560M SIGNAL
8039 LOSS OF OUTGOING 0.7M SIGNAL
8040 NO FREE CHANNEL
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 13/486
DN998797 13
Transmission Equipment Alarms (8000-8999) List of Alarms
Id:0900d80580804c95
Confidential
8042 LOSS OF OUTGOING TRANSMISSION PATH SIGNAL
8043 INCORRECT OUTGOING SIGNAL LEVEL
8044 HIGH REFLECTED POWER
8045 NO OUTGOING SIGNAL
8046 NO OUTGOING LINE SIGNAL
8047 PAYLOAD MISMATCH
8048 LOSS OF INCOMING SIGNAL
8049 LOSS OF INCOMING 64K SIGNAL
8050 LOSS OF INCOMING 2M SIGNAL
8051 LOSS OF INCOMING 8M SIGNAL
8052 LOSS OF INCOMING 34M SIGNAL
8053 LOSS OF INCOMING 140M SIGNAL
8054 LOSS OF INCOMING 560M SIGNAL
8055 LOSS OF INCOMING 0.7M SIGNAL
8056 LOSS OF INCOMING 1.5M SIGNAL
8057 LOSS OF POINTER
8058 LOSS OF INCOMING TRANSMISSION PATH SIGNAL
8059 INCORRECT INCOMING SIGNAL LEVEL
8060 NO INCOMING RADIO SIGNAL
8061 LOSS OF INCOMING LINE SIGNAL
8062 NO CONNECTION8063 NO REDUNDANT CONNECTION
8064 ALARM SIGNAL (AIS) IS RECEIVED
8065 ALARM SIGNAL (AIS 64K) IS RECEIVED
8066 ALARM INDICATION SIGNAL (AIS) RECEIVED
8067 ALARM SIGNAL (AIS 8M) IS RECEIVED
8068 ALARM SIGNAL (AIS 34M) IS RECEIVED
8069 ALARM SIGNAL (AIS 140M) IS RECEIVED
8070 ALARM SIGNAL (AIS 560M) IS RECEIVED
8071 ALARM SIGNAL (AIS 0.7M) IS RECEIVED
8072 ALARM SIGNAL (AIS 16K) IS RECEIVED
8073 ALARM INDICATION SIGNAL (AIS) RECEIVED
8074 ALARM INDICATION SIGNAL RECEIVED ON TIMESLOT 16
8075 S ALARM RECEIVED
8076 GENERAL ALARM IN NETWORK RECEIVED
8077 LOOPED SIGNAL RECEIVED
8078 MEASUREMENT SIGNAL RECEIVED
8079 TS16 CODE ERROR RECEIVED
8080 FRAME ERROR
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 14/486
14 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
List of Alarms
8081 LOSS OF FRAME ALIGNMENT
8082 MULTIFRAME ALIGNMENT LOST
8083 LOSS OF FRAME ALIGNMENT OF SUBSYSTEM
8084 LOSS OF LINE FRAME ALIGNMENT
8085 LOSS OF RADIO FRAME ALIGNMENT
8086 LOSS OF CRC MULTIFRAME ALIGNMENT
8087 LOSS OF OCTET TIMING
8088 END TO END FRAME LOSS
8089 LOSS OF SIGNALLING FRAME
8096 EXCESSIVE ERROR RATE
8097 BIT ERROR RATIO (BER) > 1E-1
8098 BIT ERROR RATIO (BER) > 1E-2
8099 RECEIVED BIT ERROR RATIO (BER) > 1E-3
8100 RECEIVED BIT ERROR RATIO (BER) > 1E-4
8101 RECEIVED BIT ERROR RATIO (BER) > 1E-5
8102 RECEIVED BIT ERROR RATIO (BER) > 1E-6
8103 BIT ERROR RATIO (BER) > 1E-7
8104 BIT ERROR RATIO (BER) > 1E-8
8105 BIT ERROR RATIO (BER) > 1E-9
8106 BIT ERROR RATIO (BER) > 1E-10
8107 BIT ERROR RATIO (BER) > 1E-118108 BIT ERROR RATIO (BER) > 1E-12
8109 FADING IN TRANSMISSION PATH
8110 SELECTIVE FADING IN TRANSMISSION PATH
8111 MODULATION ERROR
8112 FREQUENCY ERROR
8113 BUFFER OVERFLOW
8119 SYNCHRONIZING FAULT IN TRANSMITTER
8120 SYNCHRONIZING FAULT IN RECEIVER
8121 SYNCHRONIZING FAULT IN AUXILIARY CHANNEL
8122 SYNCHRONIZING FAULT
8123 SYNCHRONIZING FAULT IN CARRIER RECOVERY
8124 SYNCHRONIZATION FAULT IN CLOCK RECOVERY
8125 LOSS OF SYNCHRONIZATION SIGNAL
8126 UNIT FUNCTION DEGRADED
8127 EQUIPMENT FAULT DETECTED IN AUTOMATIC LOOP TEST
8128 FAULT IN EQUIPMENT
8129 FAULT IN CODEC
8130 FAULT IN MEMORY
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 15/486
DN998797 15
Transmission Equipment Alarms (8000-8999) List of Alarms
Id:0900d80580804c95
Confidential
8131 INTERNAL BUS FAULT
8132 FAULT IN SUMMING UNIT
8133 FAULT IN MUX
8134 EXCHANGE LINE ALARM
8135 EQUIPMENT IN RESET
8136 AIS OSCILLATOR FAULT
8137 OSCILLATOR FAULT
8138 PRESSURE ALARM
8139 SUBRACK HAS MISSING UNITS
8140 SUBRACK HAS EXCESSIVE UNITS
8141 FORCED CONTROL ON
8142 INSTALLATION ERROR
8143 FAULT IN CHANGE OVER FUNCTION
8144 OPERATING ERROR
8145 TEMPERATURE ALARM
8146 WIND ALARM
8147 LOCAL ALARM CANCEL WITHOUT ANY ALARM
8148 EQUIPMENT RESET
8149 FORCED INDICATION
8150 FAULT IN UNIT
8151 FAULT IN CHANNEL8152 FAULT IN BLOCK
8153 FAULT IN TRANSMITTER
8154 FAULT IN RECEIVER
8155 LASER BIAS OUT OF RANGE
8156 LASER POWER OUT OF RANGE
8157 LASER TEMPERATURE OUT OF RANGE
8158 FORCED LASER CUT OFF
8159 RUN DIAGNOSTICS TEST
8160 INTERFACE UNIT FAULT
8161 CONNECTED TO REDUNDANT SYSTEM
8162 DATABASE FULL
8163 REDUNDANT CONNECTION IN USE
8164 LINE CABLE FAULT
8165 REAL TIME LOST
8166 E1 CONVERTER RESET
8167 E1 CONVERTER FAULT
8168 EQUIPMENT DOOR OPEN
8169 EXTENDED FAULT CODE IN USE
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 16/486
16 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
List of Alarms
8172 YELLOW ALARM OCCURRED
8173 FAR-END ALARM 4
8174 FAR-END ALARM 3
8175 FAR-END ALARM 2
8176 FAR-END ALARM RECEIVED
8178 MULTIFRAME ALARM FROM FAR-END
8179 FAR-END ALARM
8180 ALARM FROM FAR-END SUBSYSTEM
8181 FAR-END SENDING FAULT
8182 FAULT IN FAR-END RECEIVING
8183 FAR-END SYNCHRONIZATION ALARM
8184 REAL TIME UPDATED
8185 CONNECTION OR SETTINGS HAVE CHANGED
8186 CONFIGURATION ERROR
8190 CUSTOMER SPECIFIC FAULT CODE 1
8191 CUSTOMER SPECIFIC FAULT CODE 2
8192 CUSTOMER SPECIFIC FAULT CODE 3
8193 CUSTOMER SPECIFIC FAULT CODE 4
8194 CUSTOMER SPECIFIC FAULT CODE 5
8195 V5 PROTOCOL ALARM
8200 LOSS OF PRIMARY SUPERVISION CONNECTION8201 LOSS OF SECONDARY SUPERVISION CONNECTION
8202 LOSS OF SUPERVISION CONNECTION
8203 LOSS OF SUPERVISION BUS
8206 CONGESTION
8207 CALIBRATION EXPIRED
8213 REMOTE DEFECT INDICATION (RDI)
8214 SIGNAL DEGRADED
8215 TRACE IDENTIFIER MISMATCH
8216 UNEQUIPPED SIGNAL
8221 VERSION MISMATCH
8222 CORRUPT DATA
8223 PROTECTION SWITCH
8230 THRESHOLD CROSSED
8240 ACTIVE ALARM POINT
8241 UPPER ALARM LIMIT EXCEEDED
8242 LOWER ALARM LIMIT EXCEEDED
8250 INVALID TIME
8254 OPERATOR DISABLED
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 17/486
DN998797 17
Transmission Equipment Alarms (8000-8999) List of Alarms
Id:0900d80580804c95
Confidential
8256 15 MIN G826 ES THRESHOLD CROSSED
8257 15 MIN G826 SES THRESHOLD CROSSED
8258 15 MIN G826 BBE THRESHOLD CROSSED
8259 24 H G826 ES THRESHOLD CROSSED
8260 24 H G826 SES THRESHOLD CROSSED
8261 24 H G826 BBE THRESHOLD CROSSED
8262 STATISTIC UNAVAILABILITY
8263 STATISTIC RESET
8264 15 MIN T/RLTS THRESHOLD CROSSED
8265 24 H T/RLTS THRESHOLD CROSSED
8266 LICENCE KEY NOT VALID
8267 LICENCE EXPIRED
8268 LICENCE WILL EXPIRE IN THE NEAR FUTURE
8269 LICENCE FOR FEATURE IS NOT AVAILABLE
8270 LICENCE FOR FEATURE HAS BEEN ACTIVATED
8271 LICENCE FOR FEATURE HAS BEEN DEACTIVATED
8272 POSITION NOT LOCKED
8273 LICENCE FOR 2G FLEXI ABIS OVER IP/ETHERNET IS NOT AVAIL-
ABLE
8274 LICENCE FOR 2G FLEXI ADDITIONAL 2 E1/T1 IS NOT AVAILABLE
8275 LICENCE FOR 2G FLEXI ABIS TRS GROOMING IS NOT AVAILABLE
8276 LICENCE FOR 2G FLEXI TRS LOOP PROTECTION IS NOT AVAIL-
ABLE
8277 ETHERNET PHYSICAL LINK LAYER LOST
8278 PSEUDOWIRE DOWN
8279 PSEUDOWIRE PERFORMANCE DEGRADED
8280 PSEUDOWIRE REMOTE PACKET LOSS
8281 FAULT IN OPTICAL INTERFACE (SFP)
8282 PSEUDOWIRE TUNNEL DOWN
8283 LICENCE FOR IP SECURITY IS NOT AVAILABLE
8284 TRAFFIC SHAPING MISCONFIGURATION
8285 LICENCE FOR TIMING OVER PACKET IS NOT AVAILABLE
8286 LICENCE FOR SYNCHRONOUS ETHERNET IS NOT AVAILABLE
8287 CLOCK RECOVERY IN PROGRESS
8288 FAULT IN CONNECTION TO CLOCK MASTER
8289 SSM HAS LOST TRACEABILITY TO PRC CLOCK SOURCE
8290 LICENCE FOR PACKET TRS E1/T1 IS NOT AVAILABLE
8291 PMTU BTS TO BSC LESS THAN CONFIGRUED MTU
8292 PMTU BTS TO SECURITY GATEWAY LESS THAN CONFIGUREDMTU
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 18/486
18 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
Transmission equipment parameters (DX 200 AlarmSystem)
2 Transmission equipment parameters (DX
200 Alarm System)
ALARM CLS OUT IDL IDD CDL ALV
8000 *** ALARM 1 00:00 00:00 00:00 -
8001 *** ALARM 1 00:00 00:10 00:10 -
8002 *** ALARM 1 00:00 00:10 00:10 -
8003 *** ALARM 1 00:00 00:10 00:10 -
8004 *** ALARM 1 00:00 00:10 00:10 -
8005 *** ALARM 1 00:00 00:10 00:10 -
8006 *** ALARM 1 00:00 00:10 00:10 -
8007 *** ALARM 1 00:00 00:10 00:10 -
8008 *** ALARM 1 00:00 00:10 00:10 -
8009 *** ALARM 1 00:00 00:10 00:10 -
8010 *** ALARM 1 00:00 00:10 00:10 -8011 *** ALARM 1 00:00 00:10 00:10 -
8012 *** ALARM 1 00:00 00:10 00:10 -
8013 ** ALARM 5 00:00 00:10 00:10 -
8014 NOTICE NONE 00:00 00:00 00:00 00:00:15
8016 *** ALARM 1 00:00 00:10 00:10 -
8017 *** ALARM 1 00:00 00:10 00:10 -
8018 *** ALARM 1 00:00 00:10 00:10 -
8019 *** ALARM 1 00:00 00:10 00:10 -
8020 ** ALARM 5 00:00 00:10 00:10 -
8021 ** ALARM 5 00:00 00:10 00:10 -
8022 ** ALARM 5 00:00 00:10 00:10 -
8023 ** ALARM 5 00:00 00:10 00:10 -
8024 *** ALARM 1 00:00 00:10 00:10 -
8025 ** ALARM 5 00:00 00:10 00:10 -
8026 ** ALARM 5 00:00 00:10 00:10 -
8027 ** ALARM 5 00:00 00:10 00:10 -
8028 ** ALARM 5 00:00 00:10 00:10 -
8032 *** ALARM 1 00:00 00:10 00:10 -
8033 *** ALARM 1 00:00 00:10 00:10 -
8034 *** ALARM 1 00:00 00:10 00:10 -
8035 *** ALARM 1 00:00 00:10 00:10 -
8036 *** ALARM 1 00:00 00:10 00:10 -
8037 *** ALARM 1 00:00 00:10 00:10 -8038 *** ALARM 1 00:00 00:10 00:10 -
8039 *** ALARM 1 00:00 00:10 00:10 -
8040 DISTUR NONE 00:00 00:00 00:00 00:00:15
8042 *** ALARM 1 00:00 00:10 00:10 -
8043 *** ALARM 1 00:00 00:10 00:10 -
8044 *** ALARM 1 00:00 00:10 00:10 -
8045 *** ALARM 1 00:00 00:10 00:10 -
8046 *** ALARM 1 00:00 00:10 00:10 -
8047 *** ALARM 1 00:00 00:10 00:10 -
8048 *** ALARM 1 00:00 00:10 00:10 -
8049 *** ALARM 1 00:00 00:10 00:10 -
8050 *** ALARM 1 00:00 00:10 00:10 -
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 19/486
DN998797 19
Transmission Equipment Alarms (8000-8999) Transmission equipment parameters (DX 200 AlarmSystem)
Id:0900d80580804c95
Confidential
8051 *** ALARM 1 00:00 00:10 00:10 -
8052 *** ALARM 1 00:00 00:10 00:10 -
8053 *** ALARM 1 00:00 00:10 00:10 -
8054 *** ALARM 1 00:00 00:10 00:10 -
8055 *** ALARM 1 00:00 00:10 00:10 -
8056 *** ALARM 1 00:00 00:10 00:10 -
8057 *** ALARM 1 00:00 00:10 00:10 -
8058 *** ALARM 1 00:00 00:10 00:10 -
8059 *** ALARM 1 00:00 00:10 00:10 -
8060 *** ALARM 1 00:00 00:10 00:10 -
8061 *** ALARM 1 00:00 00:10 00:10 -
8062 *** ALARM 1 00:00 00:10 00:10 -
8063 *** ALARM 1 00:00 00:10 00:10 -
8064 ** ALARM 5 00:00 00:10 00:10 -
8065 ** ALARM 5 00:00 00:10 00:10 -
8066 ** ALARM 5 00:00 00:10 00:10 -8067 ** ALARM 5 00:00 00:10 00:10 -
8068 ** ALARM 5 00:00 00:10 00:10 -
8069 ** ALARM 5 00:00 00:10 00:10 -
8070 ** ALARM 5 00:00 00:10 00:10 -
8071 ** ALARM 5 00:00 00:10 00:10 -
8072 ** ALARM 5 00:00 00:10 00:10 -
8073 ** ALARM 5 00:00 00:10 00:10 -
8074 ** ALARM 5 00:00 00:10 00:10 -
8075 ** ALARM 5 00:00 00:10 00:10 -
8076 ** ALARM 5 00:00 00:10 00:10 -
8077 ** ALARM 5 00:00 00:10 00:10 -
8078 ** ALARM 5 00:00 00:10 00:10 -
8079 ** ALARM 5 00:00 00:10 00:10 -
8080 *** ALARM 1 00:00 00:10 00:10 -
8081 *** ALARM 1 00:00 00:10 00:10 -
8082 *** ALARM 1 00:00 00:10 00:10 -
8083 *** ALARM 1 00:00 00:10 00:10 -
8084 *** ALARM 1 00:00 00:10 00:10 -
8085 *** ALARM 1 00:00 00:10 00:10 -
8086 *** ALARM 1 00:00 00:10 00:10 -
8087 *** ALARM 1 00:00 00:10 00:10 -
8088 *** ALARM 1 00:00 00:10 00:10 -
8089 *** ALARM 1 00:00 00:10 00:10 -
8096 *** ALARM 1 00:00 00:10 00:10 -
8097 *** ALARM 1 00:00 00:10 00:10 -
8098 *** ALARM 1 00:00 00:10 00:10 -
8099 *** ALARM 1 00:00 00:15 00:10 -
8100 ** ALARM 5 00:00 00:10 00:10 -
8101 ** ALARM 5 00:00 00:10 00:10 -
8102 ** ALARM 5 00:00 00:30 00:40 -
8103 * ALARM NONE 00:00 00:10 00:10 -
8104 * ALARM NONE 00:00 00:10 00:10 -
8105 * ALARM NONE 00:00 00:10 00:10 -
8106 * ALARM NONE 00:00 00:10 00:10 -8107 * ALARM NONE 00:00 00:10 00:10 -
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 20/486
20 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
Transmission equipment parameters (DX 200 AlarmSystem)
8108 * ALARM NONE 00:00 00:10 00:10 -
8109 ** ALARM 5 00:00 00:10 00:10 -
8110 ** ALARM 5 00:00 00:10 00:10 -
8111 *** ALARM 1 00:00 00:10 00:10 -
8112 * ALARM NONE 00:00 00:10 00:10 -
8113 * ALARM NONE 00:00 00:10 00:10 -
8119 ** ALARM 5 00:00 00:10 00:10 -
8120 ** ALARM 5 00:00 00:10 00:10 -
8121 ** ALARM 5 00:00 00:10 00:10 -
8122 ** ALARM 5 00:00 00:10 00:10 -
8123 ** ALARM 5 00:00 00:10 00:10 -
8124 ** ALARM 5 00:00 00:10 00:10 -
8125 *** ALARM 1 00:00 00:10 00:10 -
8126 ** ALARM 5 00:00 00:10 00:10 -
8127 ** ALARM 5 00:00 00:10 00:10 -
8128 ** ALARM 5 00:00 00:10 00:10 -8129 ** ALARM 5 00:00 00:10 00:10 -
8130 ** ALARM 5 00:00 00:10 00:10 -
8131 ** ALARM 5 00:00 00:10 00:10 -
8132 ** ALARM 5 00:00 00:10 00:10 -
8133 ** ALARM 5 00:00 00:10 00:10 -
8134 ** ALARM 5 00:00 00:10 00:10 -
8135 ** ALARM 5 00:00 00:10 00:10 -
8136 ** ALARM 5 00:00 00:10 00:10 -
8137 ** ALARM 5 00:00 00:10 00:10 -
8138 ** ALARM 5 00:00 00:10 00:10 -
8139 *** ALARM 1 00:00 00:10 00:10 -
8140 ** ALARM 5 00:00 00:10 00:10 -
8141 *** ALARM 1 00:00 00:10 00:10 -
8142 *** ALARM 1 00:00 00:10 00:10 -
8143 *** ALARM 1 00:00 00:10 00:10 -
8144 *** ALARM 1 00:00 00:10 00:10 -
8145 ** ALARM 5 00:00 00:10 00:10 -
8146 ** ALARM 5 00:00 00:10 00:10 -
8147 NOTICE NONE 00:00 00:00 00:00 00:00:15
8148 NOTICE NONE 00:00 00:00 00:00 00:00:15
8149 NOTICE NONE 00:00 00:00 00:00 00:00:15
8150 *** ALARM 1 00:00 00:10 00:10 -
8151 *** ALARM 1 00:00 00:10 00:10 -
8152 *** ALARM 1 00:00 00:10 00:10 -
8153 *** ALARM 1 00:00 00:10 00:10 -
8154 *** ALARM 1 00:00 00:10 00:10 -
8155 *** ALARM 1 00:00 00:10 00:10 -
8156 *** ALARM 1 00:00 00:10 00:10 -
8157 *** ALARM 1 00:00 00:10 00:10 -
8158 *** ALARM 1 00:00 00:10 00:10 -
8159 *** ALARM 1 00:00 00:10 00:10 -
8160 *** ALARM 1 00:00 00:10 00:10 -
8161 ** ALARM 5 00:00 00:10 00:10 -
8162 NOTICE NONE 00:00 00:00 00:00 00:00:158163 ** ALARM 5 00:00 00:10 00:10 -
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 21/486
DN998797 21
Transmission Equipment Alarms (8000-8999) Transmission equipment parameters (DX 200 AlarmSystem)
Id:0900d80580804c95
Confidential
8164 *** ALARM 1 00:00 00:10 00:10 -
8165 ** ALARM 5 00:00 00:10 00:10 -
8166 ** ALARM 5 00:00 00:10 00:10 -
8167 *** ALARM 1 00:00 00:10 00:10 -
8168 * ALARM NONE 00:00 00:10 00:10 -
8169 * ALARM NONE 00:00 00:10 00:10 -
8172 ** ALARM 5 00:00 00:10 00:10 -
8173 DISTUR NONE 00:00 00:00 00:00 00:00:15
8174 * ALARM NONE 00:00 00:10 00:10 -
8175 ** ALARM 5 00:00 00:10 00:10 -
8176 *** ALARM 1 00:00 00:10 00:10 -
8178 ** ALARM 5 00:00 00:10 00:10 -
8179 ** ALARM 5 00:00 00:10 00:10 -
8180 ** ALARM 5 00:00 00:10 00:10 -
8181 ** ALARM 5 00:00 00:10 00:10 -
8182 ** ALARM 5 00:00 00:10 00:10 -8183 ** ALARM 5 00:00 00:10 00:10 -
8184 NOTICE NONE 00:00 00:00 00:00 00:00:15
8185 DISTUR NONE 00:00 00:00 00:00 00:00:15
8186 * ALARM NONE 00:00 00:00 00:00 -
8190 * ALARM NONE 00:00 00:00 00:00 -
8191 * ALARM NONE 00:00 00:00 00:00 -
8192 * ALARM NONE 00:00 00:00 00:00 -
8193 ** ALARM 5 00:00 00:00 00:00 -
8194 ** ALARM 5 00:00 00:00 00:00 -
8195 *** ALARM 1 00:00 00:00 00:00 -
8200 ** ALARM 5 00:00 00:00 00:00 -
8201 ** ALARM 5 00:00 00:00 00:00 -
8202 *** ALARM 1 00:00 00:00 00:00 -
8203 *** ALARM 1 00:00 00:00 00:00 -
8206 DISTUR NONE 00:00 00:00 00:00 00:00:15
8207 DISTUR NONE 00:00 00:00 00:00 00:00:15
8213 ** ALARM 5 00:00 00:00 00:00 -
8214 ** ALARM 5 00:00 00:00 00:00 -
8215 *** ALARM 1 00:00 00:00 00:00 -
8216 *** ALARM 1 00:00 00:00 00:00 -
8221 *** ALARM 1 00:00 00:00 00:00 -
8222 *** ALARM 1 00:00 00:00 00:00 -
8223 DISTUR NONE 00:00 00:00 00:00 00:00:15
8230 NOTICE NONE 00:00 00:00 00:00 00:00:15
8240 ** ALARM 5 00:00 00:00 00:00 -
8241 *** ALARM 1 00:00 00:00 00:00 -
8242 * ALARM NONE 00:00 00:00 00:00 -
8250 * ALARM NONE 00:00 00:00 00:00 -
8254 NOTICE NONE 00:00 00:00 00:00 00:00:15
8256 * ALARM NONE 00:00 00:00 00:00 -
8257 ** ALARM 5 00:00 00:00 00:00 -
8258 * ALARM NONE 00:00 00:00 00:00 -
8259 NOTICE NONE 00:00 00:00 00:00 00:00:15
8260 NOTICE NONE 00:00 00:00 00:00 00:00:158261 NOTICE NONE 00:00 00:00 00:00 00:00:15
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 22/486
22 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
Transmission equipment parameters (DX 200 AlarmSystem)
8262 *** ALARM 1 00:00 00:00 00:00 -
8263 NOTICE NONE 00:00 00:00 00:00 00:00:15
8264 ** ALARM 5 00:00 00:00 00:00 -
8265 NOTICE NONE 00:00 00:00 00:00 00:00:15
8266 *** ALARM 1 00:00 00:00 00:00 -
8267 *** ALARM 1 00:00 00:00 00:00 -
8268 ** ALARM 5 00:00 00:00 00:00 -
8269 *** ALARM 1 00:00 00:00 00:00 -
8270 NOTICE NONE 00:00 00:00 00:00 00:00:15
8271 NOTICE NONE 00:00 00:00 00:00 00:00:15
8272 * ALARM NONE 00:10 00:10 00:10 -
8273 *** ALARM 1 00:10 00:10 00:10 -
8274 *** ALARM 1 00:10 00:10 00:10 -
8275 * ALARM NONE 00:10 00:10 00:10 -
8276 * ALARM NONE 00:10 00:10 00:10 -
8277 *** ALARM 1 00:10 00:10 00:10 -8278 *** ALARM 1 00:10 00:10 00:10 -
8279 ** ALARM 5 00:10 00:10 00:10 -
8280 ** ALARM 5 00:10 00:10 00:10 -
8281 *** ALARM 1 00:10 00:10 00:10 -
8282 ** ALARM 5 00:10 00:10 00:10 -
8283 *** ALARM 1 00:10 00:10 00:10 -
8284 ** ALARM 5 00:10 00:10 00:10 -
8285 ** ALARM 5 00:10 00:10 00:10 -
8286 *** ALARM 1 00:10 00:10 00:10 -
8287 * ALARM NONE 00:10 00:10 00:10 -
8288 ** ALARM 5 00:10 00:10 00:10 -
8289 ** ALARM 5 00:10 00:10 00:10 -
8290 ** ALARM 5 00:10 00:10 00:10 -
8291 ** ALARM 5 00:10 00:10 00:10 -
8292 * ALARM NONE 00:10 00:10 00:10 -
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 23/486
DN998797 23
Transmission Equipment Alarms (8000-8999) Transmission equipment parameters (BTS Alarm Sys-tem)
Id:0900d80580804c95
Confidential
3 Transmission equipment parameters (BTS
Alarm System)
NUMBER CLASS RECOVERY PRINTING OMC UPD. IDL CDL STATE
8000 *** ON OFF ON 10 10 UNBLOCKED
8001 *** ON OFF ON 10 10 UNBLOCKED
8002 *** ON OFF ON 10 10 UNBLOCKED
8003 *** ON OFF ON 10 10 UNBLOCKED
8004 *** ON OFF ON 10 10 UNBLOCKED
8005 *** ON OFF ON 10 10 UNBLOCKED
8006 *** ON OFF ON 10 10 UNBLOCKED
8007 *** ON OFF ON 10 10 UNBLOCKED
8008 *** ON OFF ON 10 10 UNBLOCKED
8009 *** ON OFF ON 10 10 UNBLOCKED
8010 *** ON OFF ON 10 10 UNBLOCKED8011 *** ON OFF ON 10 10 UNBLOCKED
8012 *** ON OFF ON 10 10 UNBLOCKED
8013 ** ON OFF ON 10 10 UNBLOCKED
8014 ON OFF ON 10 10 UNBLOCKED
8016 *** ON OFF ON 10 10 UNBLOCKED
8017 *** ON OFF ON 10 10 UNBLOCKED
8018 *** ON OFF ON 10 10 UNBLOCKED
8019 *** ON OFF ON 10 10 UNBLOCKED
8020 ** ON OFF ON 10 10 UNBLOCKED
8021 ** ON OFF ON 10 10 UNBLOCKED
8022 ** ON OFF ON 10 10 UNBLOCKED
8023 ** ON OFF ON 10 10 UNBLOCKED
8024 *** ON OFF ON 10 10 UNBLOCKED
8025 ** ON OFF ON 10 10 UNBLOCKED
8026 ** ON OFF ON 10 10 UNBLOCKED
8027 ** ON OFF ON 10 10 UNBLOCKED
8028 ** ON OFF ON 10 10 UNBLOCKED
8032 *** ON OFF ON 10 10 UNBLOCKED
8033 *** ON OFF ON 10 10 UNBLOCKED
8034 *** ON OFF ON 10 10 UNBLOCKED
8035 *** ON OFF ON 10 10 UNBLOCKED
8036 *** ON OFF ON 10 10 UNBLOCKED
8037 *** ON OFF ON 10 10 UNBLOCKED8038 *** ON OFF ON 10 10 UNBLOCKED
8039 *** ON OFF ON 10 10 UNBLOCKED
8040 ON OFF ON 10 10 UNBLOCKED
8042 *** ON OFF ON 10 10 UNBLOCKED
8043 *** ON OFF ON 10 10 UNBLOCKED
8044 *** ON OFF ON 10 10 UNBLOCKED
8045 *** ON OFF ON 10 10 UNBLOCKED
8046 *** ON OFF ON 10 10 UNBLOCKED
8047 *** ON OFF ON 10 10 UNBLOCKED
8048 *** ON OFF ON 10 10 UNBLOCKED
8049 *** ON OFF ON 10 10 UNBLOCKED
8050 *** ON OFF ON 10 10 UNBLOCKED
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 24/486
24 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
Transmission equipment parameters (BTS Alarm Sys-tem)
8051 *** ON OFF ON 10 10 UNBLOCKED
8052 *** ON OFF ON 10 10 UNBLOCKED
8053 *** ON OFF ON 10 10 UNBLOCKED
8054 *** ON OFF ON 10 10 UNBLOCKED
8055 *** ON OFF ON 10 10 UNBLOCKED
8056 *** ON OFF ON 10 10 UNBLOCKED
8057 *** ON OFF ON 10 10 UNBLOCKED
8058 *** ON OFF ON 10 10 UNBLOCKED
8059 *** ON OFF ON 10 10 UNBLOCKED
8060 *** ON OFF ON 10 10 UNBLOCKED
8061 *** ON OFF ON 10 10 UNBLOCKED
8062 *** ON OFF ON 10 10 UNBLOCKED
8063 *** ON OFF ON 10 10 UNBLOCKED
8064 ** ON OFF ON 10 10 UNBLOCKED
8065 ** ON OFF ON 10 10 UNBLOCKED
8066 ** ON OFF ON 10 10 UNBLOCKED8067 ** ON OFF ON 10 10 UNBLOCKED
8068 ** ON OFF ON 10 10 UNBLOCKED
8069 ** ON OFF ON 10 10 UNBLOCKED
8070 ** ON OFF ON 10 10 UNBLOCKED
8071 ** ON OFF ON 10 10 UNBLOCKED
8072 ** ON OFF ON 10 10 UNBLOCKED
8073 ** ON OFF ON 10 10 UNBLOCKED
8074 ** ON OFF ON 10 10 UNBLOCKED
8075 ** ON OFF ON 10 10 UNBLOCKED
8076 ** ON OFF ON 10 10 UNBLOCKED
8077 ** ON OFF ON 10 10 UNBLOCKED
8078 ** ON OFF ON 10 10 UNBLOCKED
8079 ** ON OFF ON 10 10 UNBLOCKED
8080 *** ON OFF ON 10 10 UNBLOCKED
8081 *** ON OFF ON 10 10 UNBLOCKED
8082 *** ON OFF ON 10 10 UNBLOCKED
8083 *** ON OFF ON 10 10 UNBLOCKED
8084 *** ON OFF ON 10 10 UNBLOCKED
8085 *** ON OFF ON 10 10 UNBLOCKED
8086 *** ON OFF ON 10 10 UNBLOCKED
8087 *** ON OFF ON 10 10 UNBLOCKED
8088 *** ON OFF ON 10 10 UNBLOCKED
8089 *** ON OFF ON 10 10 UNBLOCKED
8096 *** ON OFF ON 10 10 UNBLOCKED
8097 *** ON OFF ON 10 10 UNBLOCKED
8098 *** ON OFF ON 10 10 UNBLOCKED
8099 *** ON OFF ON 15 10 UNBLOCKED
8100 ** ON OFF ON 10 10 UNBLOCKED
8101 ** ON OFF ON 10 10 UNBLOCKED
8102 ** ON OFF ON 30 40 UNBLOCKED
8103 * ON OFF ON 10 10 UNBLOCKED
8104 * ON OFF ON 10 10 UNBLOCKED
8105 * ON OFF ON 10 10 UNBLOCKED
8106 * ON OFF ON 10 10 UNBLOCKED8107 * ON OFF ON 10 10 UNBLOCKED
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 25/486
DN998797 25
Transmission Equipment Alarms (8000-8999) Transmission equipment parameters (BTS Alarm Sys-tem)
Id:0900d80580804c95
Confidential
8108 * ON OFF ON 10 10 UNBLOCKED
8109 ** ON OFF ON 10 10 UNBLOCKED
8110 ** ON OFF ON 10 10 UNBLOCKED
8111 *** ON OFF ON 10 10 UNBLOCKED
8112 * ON OFF ON 10 10 UNBLOCKED
8113 * ON OFF ON 10 10 UNBLOCKED
8119 ** ON OFF ON 10 10 UNBLOCKED
8120 ** ON OFF ON 10 10 UNBLOCKED
8121 ** ON OFF ON 10 10 UNBLOCKED
8122 ** ON OFF ON 10 10 UNBLOCKED
8123 ** ON OFF ON 10 10 UNBLOCKED
8124 ** ON OFF ON 10 10 UNBLOCKED
8125 *** ON OFF ON 10 10 UNBLOCKED
8126 ** ON OFF ON 10 10 UNBLOCKED
8127 ** ON OFF ON 10 10 UNBLOCKED
8128 ** ON OFF ON 10 10 UNBLOCKED8129 ** ON OFF ON 10 10 UNBLOCKED
8130 ** ON OFF ON 10 10 UNBLOCKED
8131 ** ON OFF ON 10 10 UNBLOCKED
8132 ** ON OFF ON 10 10 UNBLOCKED
8133 ** ON OFF ON 10 10 UNBLOCKED
8134 ** ON OFF ON 10 10 UNBLOCKED
8135 ** ON OFF ON 10 10 UNBLOCKED
8136 ** ON OFF ON 10 10 UNBLOCKED
8137 ** ON OFF ON 10 10 UNBLOCKED
8138 ** ON OFF ON 10 10 UNBLOCKED
8139 *** ON OFF ON 10 10 UNBLOCKED
8140 ** ON OFF ON 10 10 UNBLOCKED
8141 *** ON OFF ON 10 10 UNBLOCKED
8142 *** ON OFF ON 10 10 UNBLOCKED
8143 *** ON OFF ON 10 10 UNBLOCKED
8144 *** ON OFF ON 10 10 UNBLOCKED
8145 ** ON OFF ON 10 10 UNBLOCKED
8146 ** ON OFF ON 10 10 UNBLOCKED
8147 ON OFF ON 10 10 UNBLOCKED
8148 ON OFF ON 10 10 UNBLOCKED
8149 ON OFF ON 10 10 UNBLOCKED
8150 *** ON OFF ON 10 10 UNBLOCKED
8151 *** ON OFF ON 10 10 UNBLOCKED
8152 *** ON OFF ON 10 10 UNBLOCKED
8153 *** ON OFF ON 10 10 UNBLOCKED
8154 *** ON OFF ON 10 10 UNBLOCKED
8155 *** ON OFF ON 10 10 UNBLOCKED
8156 *** ON OFF ON 10 10 UNBLOCKED
8157 *** ON OFF ON 10 10 UNBLOCKED
8158 *** ON OFF ON 10 10 UNBLOCKED
8159 *** ON OFF ON 10 10 UNBLOCKED
8160 *** ON OFF ON 10 10 UNBLOCKED
8161 ** ON OFF ON 10 10 UNBLOCKED
8162 ON OFF ON 10 10 UNBLOCKED8163 ** ON OFF ON 10 10 UNBLOCKED
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 26/486
26 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
Transmission equipment parameters (BTS Alarm Sys-tem)
8164 *** ON OFF ON 10 10 UNBLOCKED
8165 ** ON OFF ON 10 10 UNBLOCKED
8166 ** ON OFF ON 10 10 UNBLOCKED
8167 *** ON OFF ON 10 10 UNBLOCKED
8168 * ON OFF ON 10 10 UNBLOCKED
8169 * ON OFF ON 10 10 UNBLOCKED
8172 ** ON OFF ON 10 10 UNBLOCKED
8173 ON OFF ON 10 10 UNBLOCKED
8174 * ON OFF ON 10 10 UNBLOCKED
8175 ** ON OFF ON 10 10 UNBLOCKED
8176 *** ON OFF ON 10 10 UNBLOCKED
8178 ** ON OFF ON 10 10 UNBLOCKED
8179 ** ON OFF ON 10 10 UNBLOCKED
8180 ** ON OFF ON 10 10 UNBLOCKED
8181 ** ON OFF ON 10 10 UNBLOCKED
8182 ** ON OFF ON 10 10 UNBLOCKED8183 ** ON OFF ON 10 10 UNBLOCKED
8184 ON OFF ON 10 10 UNBLOCKED
8185 ON OFF ON 10 10 UNBLOCKED
8186 * ON OFF ON 10 10 UNBLOCKED
8190 * ON OFF ON 10 10 UNBLOCKED
8191 * ON OFF ON 10 10 UNBLOCKED
8192 * ON OFF ON 10 10 UNBLOCKED
8193 ** ON OFF ON 10 10 UNBLOCKED
8194 ** ON OFF ON 10 10 UNBLOCKED
8195 *** ON OFF ON 10 10 UNBLOCKED
8200 ** ON OFF ON 10 10 UNBLOCKED
8201 ** ON OFF ON 10 10 UNBLOCKED
8202 *** ON OFF ON 10 10 UNBLOCKED
8203 *** ON OFF ON 10 10 UNBLOCKED
8206 ON OFF ON 10 10 UNBLOCKED
8207 ON OFF ON 10 10 UNBLOCKED
8213 ** ON OFF ON 10 10 UNBLOCKED
8214 ** ON OFF ON 10 10 UNBLOCKED
8215 *** ON OFF ON 10 10 UNBLOCKED
8216 *** ON OFF ON 10 10 UNBLOCKED
8221 *** ON OFF ON 10 10 UNBLOCKED
8222 *** ON OFF ON 10 10 UNBLOCKED
8223 ON OFF ON 10 10 UNBLOCKED
8230 ON OFF ON 10 10 UNBLOCKED
8240 ** ON OFF ON 10 10 UNBLOCKED
8241 *** ON OFF ON 10 10 UNBLOCKED
8242 * ON OFF ON 10 10 UNBLOCKED
8250 * ON OFF ON 10 10 UNBLOCKED
8254 ON OFF ON 10 10 UNBLOCKED
8256 * ON OFF ON 10 10 UNBLOCKED
8257 ** ON OFF ON 10 10 UNBLOCKED
8258 * ON OFF ON 10 10 UNBLOCKED
8259 ON OFF ON 10 10 UNBLOCKED
8260 ON OFF ON 10 10 UNBLOCKED8261 ON OFF ON 10 10 UNBLOCKED
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 27/486
DN998797 27
Transmission Equipment Alarms (8000-8999) Transmission equipment parameters (BTS Alarm Sys-tem)
Id:0900d80580804c95
Confidential
8262 *** ON OFF ON 10 10 UNBLOCKED
8263 ON OFF ON 10 10 UNBLOCKED
8264 ** ON OFF ON 10 10 UNBLOCKED
8265 ON OFF ON 10 10 UNBLOCKED
8266 *** ON OFF ON 0 0 UNBLOCKED
8267 *** ON OFF ON 0 0 UNBLOCKED
8268 ** ON OFF ON 0 0 UNBLOCKED
8269 *** ON OFF ON 0 0 UNBLOCKED
8270 ON OFF ON 10 10 UNBLOCKED
8271 ON OFF ON 10 10 UNBLOCKED
8272 * OFF OFF ON 10 10 UNBLOCKED
8273 *** OFF OFF ON 10 10 UNBLOCKED
8274 *** OFF OFF ON 10 10 UNBLOCKED
8275 * OFF OFF ON 10 10 UNBLOCKED
8276 * OFF OFF ON 10 10 UNBLOCKED
8277 *** OFF OFF ON 10 10 UNBLOCKED8278 *** OFF OFF ON 10 10 UNBLOCKED
8279 ** OFF OFF ON 10 10 UNBLOCKED
8280 ** OFF OFF ON 10 10 UNBLOCKED
8281 *** OFF OFF ON 10 10 UNBLOCKED
8282 *** OFF OFF ON 10 10 UNBLOCKED
8283 *** OFF OFF ON 0 0 UNBLOCKED
8284 ** OFF OFF ON 10 10 UNBLOCKED
8285 ** OFF OFF ON 0 0 UNBLOCKED
8286 ** OFF OFF ON 0 0 UNBLOCKED
8287 * OFF OFF ON 10 10 UNBLOCKED
8288 ** OFF OFF ON 10 10 UNBLOCKED
8289 ** OFF OFF ON 10 10 UNBLOCKED
8290 ** OFF OFF ON 0 0 UNBLOCKED
8291 ** OFF OFF ON 10 10 UNBLOCKED
8292 * OFF OFF ON 10 10 UNBLOCKED
8291 ** OFF OFF ON 10 10 UNBLOCKED
8292 * OFF OFF ON 10 10 UNBLOCKED
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 28/486
28 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8000 POWER SUPPLY FAULT
4 8000 POWER SUPPLY FAULT
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 29/486
DN998797 29
Transmission Equipment Alarms (8000-8999) 8000 POWER SUPPLY FAULT
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 30/486
30 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8001 TOTAL LOSS OF POWER SUPPLY
5 8001 TOTAL LOSS OF POWER SUPPLY
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 31/486
DN998797 31
Transmission Equipment Alarms (8000-8999) 8001 TOTAL LOSS OF POWER SUPPLY
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 32/486
32 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8002 LOSS OF BACK UP POWER SUPPLY
6 8002 LOSS OF BACK UP POWER SUPPLY
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 33/486
DN998797 33
Transmission Equipment Alarms (8000-8999) 8002 LOSS OF BACK UP POWER SUPPLY
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 34/486
34 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8003 LOSS OF REMOTE POWER SUPPLY
7 8003 LOSS OF REMOTE POWER SUPPLY
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 35/486
DN998797 35
Transmission Equipment Alarms (8000-8999) 8003 LOSS OF REMOTE POWER SUPPLY
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 36/486
36 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8004 UNBALANCE IN REMOTE POWER SUPPLY
8 8004 UNBALANCE IN REMOTE POWER
SUPPLY
Meaning
There is a fault in the power supply of a piece of transmission
equipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27. If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 37/486
DN998797 37
Transmission Equipment Alarms (8000-8999) 8004 UNBALANCE IN REMOTE POWER SUPPLY
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 38/486
38 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8005 INCORRECT RINGING VOLTAGE
9 8005 INCORRECT RINGING VOLTAGE
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 39/486
DN998797 39
Transmission Equipment Alarms (8000-8999) 8005 INCORRECT RINGING VOLTAGE
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 40/486
40 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8006 FAULT IN CENTRAL BATTERY
10 8006 FAULT IN CENTRAL BATTERY
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant.
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 41/486
DN998797 41
Transmission Equipment Alarms (8000-8999) 8006 FAULT IN CENTRAL BATTERY
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 42/486
42 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8007 FAULT IN CRITERIA VOLTAGE
11 8007 FAULT IN CRITERIA VOLTAGE
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 43/486
DN998797 43
Transmission Equipment Alarms (8000-8999) 8007 FAULT IN CRITERIA VOLTAGE
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 44/486
44 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8008 LOW BATTERY VOLTAGE
12 8008 LOW BATTERY VOLTAGE
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 45/486
DN998797 45
Transmission Equipment Alarms (8000-8999) 8008 LOW BATTERY VOLTAGE
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 46/486
46 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8009 FAULT IN CURRENT LOOP
13 8009 FAULT IN CURRENT LOOP
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 47/486
DN998797 47
Transmission Equipment Alarms (8000-8999) 8009 FAULT IN CURRENT LOOP
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 48/486
48 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8010 SUPPLY UNIT VOLTAGE INCORRECT
14 8010 SUPPLY UNIT VOLTAGE INCORRECT
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or daughter
board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 49/486
DN998797 49
Transmission Equipment Alarms (8000-8999) 8010 SUPPLY UNIT VOLTAGE INCORRECT
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 50/486
50 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8011 DISTRIBUTION FUSE FAULT
15 8011 DISTRIBUTION FUSE FAULT
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 51/486
DN998797 51
Transmission Equipment Alarms (8000-8999) 8011 DISTRIBUTION FUSE FAULT
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 52/486
52 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8012 SIGNALLING VOLTAGE FAULT
16 8012 SIGNALLING VOLTAGE FAULT
Meaning
There is a fault in the power supply of a piece of transmissionequipment power supply.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a daughter
board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 53/486
DN998797 53
Transmission Equipment Alarms (8000-8999) 8012 SIGNALLING VOLTAGE FAULT
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 54/486
54 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8013 CHARGER FAULT
17 8013 CHARGER FAULT
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 55/486
DN998797 55
Transmission Equipment Alarms (8000-8999) 8013 CHARGER FAULT
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 56/486
56 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8014 AC INPUT VOLTAGE FAILURE
18 8014 AC INPUT VOLTAGE FAILURE
Meaning
There is a fault in the power supply of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 57/486
DN998797 57
Transmission Equipment Alarms (8000-8999) 8014 AC INPUT VOLTAGE FAILURE
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 58/486
58 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8016 MAIN FUNCTION INHIBITED
19 8016 MAIN FUNCTION INHIBITED
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 59/486
DN998797 59
Transmission Equipment Alarms (8000-8999) 8016 MAIN FUNCTION INHIBITED
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 60/486
60 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8017 SIGNAL LOOPED TO TERMINAL
20 8017 SIGNAL LOOPED TO TERMINAL
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 61/486
DN998797 61
Transmission Equipment Alarms (8000-8999) 8017 SIGNAL LOOPED TO TERMINAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 62/486
62 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8018 SIGNAL IS LOOPED TO TRANSMISSION PATH
21 8018 SIGNAL IS LOOPED TO TRANSMISSION
PATH
Meaning
A user operation inhibits the normal use of a piece of transmission
equipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27. If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 63/486
DN998797 63
Transmission Equipment Alarms (8000-8999) 8018 SIGNAL IS LOOPED TO TRANSMISSION PATH
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 64/486
64 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8019 FUNCTION INHIBITED
22 8019 FUNCTION INHIBITED
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 65/486
DN998797 65
Transmission Equipment Alarms (8000-8999) 8019 FUNCTION INHIBITED
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 66/486
66 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8020 BLOCKED FROM USE
23 8020 BLOCKED FROM USE
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 67/486
DN998797 67
Transmission Equipment Alarms (8000-8999) 8020 BLOCKED FROM USE
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: A cross-connection is configured to an interface which
is not in use.
Instructions:
1. Check that all interfaces where cross connection termination
points have been set are in use. In cross connection window,
blocked cross connections are highlighted in Italic font.
2. Remove any unnecessary cross connections that have
termination point(s) to non-existing or unused interfaces.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 68/486
68 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8021 LOOP TO INTERFACE
24 8021 LOOP TO INTERFACE
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 69/486
DN998797 69
Transmission Equipment Alarms (8000-8999) 8021 LOOP TO INTERFACE
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
FLEXI EDGE:
Description: PDH test-loop to Interface activated.
Instructions:
No actions required, alarm is cancelled when interface loop is
deactivated by the user with BTS Manager or after defined
timeout.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 70/486
70 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8022 LOOP TO EQUIPMENT
25 8022 LOOP TO EQUIPMENT
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 71/486
DN998797 71
Transmission Equipment Alarms (8000-8999) 8022 LOOP TO EQUIPMENT
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
FLEXI EDGE:
Description: PDH test-loop to Equipment activated.
Instructions:
No actions required, alarm is cancelled when interface loop is
deactivated by the user with BTS Manager or after defined
timeout.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 72/486
72 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8023 TEST MODE
26 8023 TEST MODE
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 73/486
DN998797 73
Transmission Equipment Alarms (8000-8999) 8023 TEST MODE
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 74/486
74 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8024 LOOP IN EQUIPMENT
27 8024 LOOP IN EQUIPMENT
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 75/486
DN998797 75
Transmission Equipment Alarms (8000-8999) 8024 LOOP IN EQUIPMENT
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 76/486
76 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8025 TEST GENERATOR ON
28 8025 TEST GENERATOR ON
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 77/486
DN998797 77
Transmission Equipment Alarms (8000-8999) 8025 TEST GENERATOR ON
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 78/486
78 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8026 EXTERNAL TEST MODE ACTIVE
29 8026 EXTERNAL TEST MODE ACTIVE
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 79/486
DN998797 79
Transmission Equipment Alarms (8000-8999) 8026 EXTERNAL TEST MODE ACTIVE
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 80/486
80 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8027 BLOCKED FROM FAR END
30 8027 BLOCKED FROM FAR END
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 81/486
DN998797 81
Transmission Equipment Alarms (8000-8999) 8027 BLOCKED FROM FAR END
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 82/486
82 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8028 TIMESLOT RESERVED
31 8028 TIMESLOT RESERVED
Meaning
A user operation inhibits the normal use of a piece of transmissionequipment function.
This alarm may affect the provided services. The unit is not working
properly and the unit services can be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 83/486
DN998797 83
Transmission Equipment Alarms (8000-8999) 8028 TIMESLOT RESERVED
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 84/486
84 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8032 LOSS OF OUTGOING SIGNAL
32 8032 LOSS OF OUTGOING SIGNAL
Meaning
There is a fault in the outgoing signal of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 85/486
DN998797 85
Transmission Equipment Alarms (8000-8999) 8032 LOSS OF OUTGOING SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 86/486
86 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8033 LOSS OF OUTGOING 64K SIGNAL
33 8033 LOSS OF OUTGOING 64K SIGNAL
Meaning
There is a fault in the outgoing signal of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 87/486
DN998797 87
Transmission Equipment Alarms (8000-8999) 8033 LOSS OF OUTGOING 64K SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 88/486
88 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8034 LOSS OF OUTGOING 2M SIGNAL
34 8034 LOSS OF OUTGOING 2M SIGNAL
Meaning
There is a fault in the outgoing signal of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 89/486
DN998797 89
Transmission Equipment Alarms (8000-8999) 8034 LOSS OF OUTGOING 2M SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 90/486
90 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8035 LOSS OF OUTGOING 8M SIGNAL
35 8035 LOSS OF OUTGOING 8M SIGNAL
Meaning
There is a fault in the outgoing signal of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 91/486
DN998797 91
Transmission Equipment Alarms (8000-8999) 8035 LOSS OF OUTGOING 8M SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 92/486
92 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8036 LOSS OF OUTGOING 34M SIGNAL
36 8036 LOSS OF OUTGOING 34M SIGNAL
Meaning
There is a fault in the outgoing signal of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 93/486
DN998797 93
Transmission Equipment Alarms (8000-8999) 8036 LOSS OF OUTGOING 34M SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 94/486
94 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8037 LOSS OF OUTGOING 140M SIGNAL
37 8037 LOSS OF OUTGOING 140M SIGNAL
Meaning
There is a fault in the outgoing signal of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 95/486
DN998797 95
Transmission Equipment Alarms (8000-8999) 8037 LOSS OF OUTGOING 140M SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 96/486
96 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8038 LOSS OF OUTGOING 560M SIGNAL
38 8038 LOSS OF OUTGOING 560M SIGNAL
Meaning
There is a fault in the outgoing signal of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 97/486
DN998797 97
Transmission Equipment Alarms (8000-8999) 8038 LOSS OF OUTGOING 560M SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 98/486
98 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8039 LOSS OF OUTGOING 0.7M SIGNAL
39 8039 LOSS OF OUTGOING 0.7M SIGNAL
Meaning
There is a fault in the outgoing signal of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 99/486
DN998797 99
Transmission Equipment Alarms (8000-8999) 8039 LOSS OF OUTGOING 0.7M SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 100/486
100 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8040 NO FREE CHANNEL
40 8040 NO FREE CHANNEL
Meaning
There is no available channel for connection, the channel is not freeor the channel cannot be taken in use.
This alarm affects the provided services. The unit is not working
properly and the unit services may be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If the equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 101/486
DN998797 101
Transmission Equipment Alarms (8000-8999) 8040 NO FREE CHANNEL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 102/486
102 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8042 LOSS OF OUTGOING TRANSMISSION PATHSIGNAL
41 8042 LOSS OF OUTGOING TRANSMISSION
PATH SIGNAL
Meaning
There is a fault in the outgoing signal of a piece of transmission
equipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27. If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 103/486
DN998797 103
Transmission Equipment Alarms (8000-8999) 8042 LOSS OF OUTGOING TRANSMISSION PATHSIGNAL
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 104/486
104 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8043 INCORRECT OUTGOING SIGNAL LEVEL
42 8043 INCORRECT OUTGOING SIGNAL
LEVEL
Meaning
There is a fault in the outgoing signal of a piece of transmission
equipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27. If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 105/486
DN998797 105
Transmission Equipment Alarms (8000-8999) 8043 INCORRECT OUTGOING SIGNAL LEVEL
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 106/486
106 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8044 HIGH REFLECTED POWER
43 8044 HIGH REFLECTED POWER
Meaning
There is a fault in the outgoing signal of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 107/486
DN998797 107
Transmission Equipment Alarms (8000-8999) 8044 HIGH REFLECTED POWER
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 108/486
108 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8045 NO OUTGOING SIGNAL
44 8045 NO OUTGOING SIGNAL
Meaning
There is a fault in the outgoing signal of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 109/486
DN998797 109
Transmission Equipment Alarms (8000-8999) 8045 NO OUTGOING SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 110/486
110 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8046 NO OUTGOING LINE SIGNAL
45 8046 NO OUTGOING LINE SIGNAL
Meaning
There is a fault in the outgoing signal of a piece of transmissionequipment.
This alarm affects the provided services. The unit is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 111/486
DN998797 111
Transmission Equipment Alarms (8000-8999) 8046 NO OUTGOING LINE SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 112/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 113/486
DN998797 113
Transmission Equipment Alarms (8000-8999) 8047 PAYLOAD MISMATCH
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 114/486
114 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8048 LOSS OF INCOMING SIGNAL
47 8048 LOSS OF INCOMING SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 115/486
DN998797 115
Transmission Equipment Alarms (8000-8999) 8048 LOSS OF INCOMING SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: External Q1 device does not receive signal at its
interface (e.g. LMU has lost its GPS signal).
Instructions:
1. Find out the alarming Q1 device and refer to its product
documentation for more details on this alarm.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 116/486
116 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8049 LOSS OF INCOMING 64K SIGNAL
48 8049 LOSS OF INCOMING 64K SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 117/486
DN998797 117
Transmission Equipment Alarms (8000-8999) 8049 LOSS OF INCOMING 64K SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 118/486
118 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8050 LOSS OF INCOMING 2M SIGNAL
49 8050 LOSS OF INCOMING 2M SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 119/486
DN998797 119
Transmission Equipment Alarms (8000-8999) 8050 LOSS OF INCOMING 2M SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: FIxx PIU has detected no incoming signal on E1
interface. Far End Alarm bit indication (TS0/b3) is sent in Tx
direction.
Instructions:
1. Check that interface settings are the same at both ends of
the link.
2. Check that the E1 cable is connected to right interface and
cable is correctly mated to the PIU. Check the condition of
cables, connectors and in case FIPA is used, check the
correct polarities of the wire pairs.
3. Replace FIxx
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 120/486
120 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8051 LOSS OF INCOMING 8M SIGNAL
50 8051 LOSS OF INCOMING 8M SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 121/486
DN998797 121
Transmission Equipment Alarms (8000-8999) 8051 LOSS OF INCOMING 8M SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 122/486
122 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8052 LOSS OF INCOMING 34M SIGNAL
51 8052 LOSS OF INCOMING 34M SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 123/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 124/486
124 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8053 LOSS OF INCOMING 140M SIGNAL
52 8053 LOSS OF INCOMING 140M SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 125/486
DN998797 125
Transmission Equipment Alarms (8000-8999) 8053 LOSS OF INCOMING 140M SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 126/486
126 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8054 LOSS OF INCOMING 560M SIGNAL
53 8054 LOSS OF INCOMING 560M SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 127/486
DN998797 127
Transmission Equipment Alarms (8000-8999) 8054 LOSS OF INCOMING 560M SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 128/486
128 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8055 LOSS OF INCOMING 0.7M SIGNAL
54 8055 LOSS OF INCOMING 0.7M SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 129/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 130/486
130 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8056 LOSS OF INCOMING 1.5M SIGNAL
55 8056 LOSS OF INCOMING 1.5M SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 131/486
DN998797 131
Transmission Equipment Alarms (8000-8999) 8056 LOSS OF INCOMING 1.5M SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: FIxx PIU has detected no incoming signal on T1
interface. Yellow Alarm is sent in Tx direction.
1. Check that interface settings correspond to the actual link
characteristics.
2. Check that the T1 cable is connected to right interface and
cable is correctly mated to the PIU. Check the condition of
cables, connectors and correct polarities of the wire pairs.
3. Replace FIPA.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 132/486
132 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8057 LOSS OF POINTER
56 8057 LOSS OF POINTER
Meaning
Loss of Pointer condition has occurred.
This alarm affects the provided services. The unit is not working
properly and the unit services may be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If the equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 133/486
DN998797 133
Transmission Equipment Alarms (8000-8999) 8057 LOSS OF POINTER
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 134/486
134 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8058 LOSS OF INCOMING TRANSMISSION PATHSIGNAL
57 8058 LOSS OF INCOMING TRANSMISSION
PATH SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmission
equipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27. If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 135/486
DN998797 135
Transmission Equipment Alarms (8000-8999) 8058 LOSS OF INCOMING TRANSMISSION PATHSIGNAL
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 136/486
136 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8059 INCORRECT INCOMING SIGNAL LEVEL
58 8059 INCORRECT INCOMING SIGNAL LEVEL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 137/486
DN998797 137
Transmission Equipment Alarms (8000-8999) 8059 INCORRECT INCOMING SIGNAL LEVEL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 138/486
138 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8060 NO INCOMING RADIO SIGNAL
59 8060 NO INCOMING RADIO SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 139/486
DN998797 139
Transmission Equipment Alarms (8000-8999) 8060 NO INCOMING RADIO SIGNAL
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 140/486
140 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8061 LOSS OF INCOMING LINE SIGNAL
60 8061 LOSS OF INCOMING LINE SIGNAL
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 141/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 142/486
142 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8062 NO CONNECTION
61 8062 NO CONNECTION
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 143/486
DN998797 143
Transmission Equipment Alarms (8000-8999) 8062 NO CONNECTION
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 144/486
144 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8063 NO REDUNDANT CONNECTION
62 8063 NO REDUNDANT CONNECTION
Meaning
There is a fault in the incoming signal of a piece of transmissionequipment.
This alarm affects the provided services. The interface is not working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 145/486
DN998797 145
Transmission Equipment Alarms (8000-8999) 8063 NO REDUNDANT CONNECTION
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 146/486
146 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8064 ALARM SIGNAL (AIS) IS RECEIVED
63 8064 ALARM SIGNAL (AIS) IS RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised
by a BTS that supports coordin
ate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 147/486
DN998797 147
Transmission Equipment Alarms (8000-8999) 8064 ALARM SIGNAL (AIS) IS RECEIVED
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 148/486
148 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8065 ALARM SIGNAL (AIS 64K) IS RECEIVED
64 8065 ALARM SIGNAL (AIS 64K) IS RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 149/486
DN998797 149
Transmission Equipment Alarms (8000-8999) 8065 ALARM SIGNAL (AIS 64K) IS RECEIVED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 150/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 151/486
DN998797 151
Transmission Equipment Alarms (8000-8999) 8066 ALARM INDICATION SIGNAL (AIS) RECEIVED
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: The signal is cut, deteriorated or a equipment loop is
set in the far-end equipment. Alarm Indication Signal (AIS) is
indicated as "1111 1111" in all received time slots.
Instructions:
1. Check the transmission path to find where AIS insertion
occurs.
2. Check the alarms at the far-end. Refer to the product
documentation of the far-end equipment.
3. In case FIFA PIU is used, check that the microwave link
is commissioned and operational. Check that 2M cross
connections are configured at FIFA. Refer to the FIFA
product documentation for further instructions.
4. Replace FIxx.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 152/486
152 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8067 ALARM SIGNAL (AIS 8M) IS RECEIVED
66 8067 ALARM SIGNAL (AIS 8M) IS RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 153/486
DN998797 153
Transmission Equipment Alarms (8000-8999) 8067 ALARM SIGNAL (AIS 8M) IS RECEIVED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 154/486
154 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8068 ALARM SIGNAL (AIS 34M) IS RECEIVED
67 8068 ALARM SIGNAL (AIS 34M) IS RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 155/486
DN998797 155
Transmission Equipment Alarms (8000-8999) 8068 ALARM SIGNAL (AIS 34M) IS RECEIVED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 156/486
156 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8069 ALARM SIGNAL (AIS 140M) IS RECEIVED
68 8069 ALARM SIGNAL (AIS 140M) IS
RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from another
piece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 157/486
DN998797 157
Transmission Equipment Alarms (8000-8999) 8069 ALARM SIGNAL (AIS 140M) IS RECEIVED
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 158/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 159/486
DN998797 159
Transmission Equipment Alarms (8000-8999) 8070 ALARM SIGNAL (AIS 560M) IS RECEIVED
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 160/486
160 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8071 ALARM SIGNAL (AIS 0.7M) IS RECEIVED
70 8071 ALARM SIGNAL (AIS 0.7M) IS
RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from another
piece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 161/486
DN998797 161
Transmission Equipment Alarms (8000-8999) 8071 ALARM SIGNAL (AIS 0.7M) IS RECEIVED
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 162/486
162 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8072 ALARM SIGNAL (AIS 16K) IS RECEIVED
71 8072 ALARM SIGNAL (AIS 16K) IS RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 163/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 164/486
164 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8073 ALARM INDICATION SIGNAL (AIS) RECEIVED
72 8073 ALARM INDICATION SIGNAL (AIS)
RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from another
piece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 165/486
DN998797 165
Transmission Equipment Alarms (8000-8999) 8073 ALARM INDICATION SIGNAL (AIS) RECEIVED
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: The signal is cut, deteriorated or a equipment loop is
set in the far-end equipment. Alarm Indication Signal (AIS) is
indicated as "1111 1111" in all received time slots.
Instructions:
1. Check the transmission path to find where AIS insertion
occurs.
2. Check the alarms at the far-end. Refer to the product
documentation of the far-end equipment.
3. Replace FIPA.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 166/486
166 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8074 ALARM INDICATION SIGNAL RECEIVED ONTIMESLOT 16
73 8074 ALARM INDICATION SIGNAL
RECEIVED ON TIMESLOT 16
Meaning
A piece of transmission equipment receives an alarm signal from another
piece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 167/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 168/486
168 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8075 S ALARM RECEIVED
74 8075 S ALARM RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 169/486
DN998797 169
Transmission Equipment Alarms (8000-8999) 8075 S ALARM RECEIVED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 170/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 171/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 172/486
172 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8077 LOOPED SIGNAL RECEIVED
76 8077 LOOPED SIGNAL RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 173/486
DN998797 173
Transmission Equipment Alarms (8000-8999) 8077 LOOPED SIGNAL RECEIVED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 174/486
174 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8078 MEASUREMENT SIGNAL RECEIVED
77 8078 MEASUREMENT SIGNAL RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 175/486
DN998797 175
Transmission Equipment Alarms (8000-8999) 8078 MEASUREMENT SIGNAL RECEIVED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 176/486
176 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8079 TS16 CODE ERROR RECEIVED
78 8079 TS16 CODE ERROR RECEIVED
Meaning
A piece of transmission equipment receives an alarm signal from anotherpiece of equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 177/486
DN998797 177
Transmission Equipment Alarms (8000-8999) 8079 TS16 CODE ERROR RECEIVED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 178/486
178 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8080 FRAME ERROR
79 8080 FRAME ERROR
Meaning
A framing error has been detected in the input signal.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 179/486
DN998797 179
Transmission Equipment Alarms (8000-8999) 8080 FRAME ERROR
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 180/486
180 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8081 LOSS OF FRAME ALIGNMENT
80 8081 LOSS OF FRAME ALIGNMENT
Meaning
A framing error has been detected in the input signal.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 181/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 182/486
182 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8082 MULTIFRAME ALIGNMENT LOST
81 8082 MULTIFRAME ALIGNMENT LOST
Meaning
A framing error has been detected in the input signal.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 183/486
DN998797 183
Transmission Equipment Alarms (8000-8999) 8082 MULTIFRAME ALIGNMENT LOST
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 184/486
184 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8083 LOSS OF FRAME ALIGNMENT OF SUBSYS-TEM
82 8083 LOSS OF FRAME ALIGNMENT OF SUB-
SYSTEM
Meaning
A framing error has been detected in the input signal.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 185/486
DN998797 185
Transmission Equipment Alarms (8000-8999) 8083 LOSS OF FRAME ALIGNMENT OF SUBSYS-TEM
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 186/486
186 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8084 LOSS OF LINE FRAME ALIGNMENT
83 8084 LOSS OF LINE FRAME ALIGNMENT
Meaning
A framing error has been detected in the input signal.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 187/486
DN998797 187
Transmission Equipment Alarms (8000-8999) 8084 LOSS OF LINE FRAME ALIGNMENT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 188/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 189/486
DN998797 189
Transmission Equipment Alarms (8000-8999) 8085 LOSS OF RADIO FRAME ALIGNMENT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 190/486
190 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8086 LOSS OF CRC MULTIFRAME ALIGNMENT
85 8086 LOSS OF CRC MULTIFRAME ALIGN-
MENT
Meaning
A framing error has been detected in the input signal.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 191/486
DN998797 191
Transmission Equipment Alarms (8000-8999) 8086 LOSS OF CRC MULTIFRAME ALIGNMENT
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: CRC multiframe alignment signal lost or not received
on PDH interface. CRC multiframe alignment word is conveyed in
TS0 spread over a multiframe consisting of 16 E1 frames. Far End
Alarm bit indication (TS0/b3) is sent in Tx direction.
Instructions:
1. Check that the interface settings are the same at both ends and
the CRC is set in use.
2. Check that the far-end device is able to transmit signal with
CRC multiframe alignment enabled.
3. Check the condition of cables, connectors and correct polarities
of the wire pairs.
4. Check the signal quality of the transmission path to the alarming
equipment.
5. Replace FIxx.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 192/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 193/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 194/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 195/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 196/486
196 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8089 LOSS OF SIGNALLING FRAME
88 8089 LOSS OF SIGNALLING FRAME
Meaning
A framing error has been detected in the input signal.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 197/486
DN998797 197
Transmission Equipment Alarms (8000-8999) 8089 LOSS OF SIGNALLING FRAME
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 198/486
198 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8096 EXCESSIVE ERROR RATE
89 8096 EXCESSIVE ERROR RATE
Meaning
The bit error rate has been exceeded in the input signal.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 199/486
DN998797 199
Transmission Equipment Alarms (8000-8999) 8096 EXCESSIVE ERROR RATE
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 200/486
200 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8097 BIT ERROR RATIO (BER) > 1E-1
90 8097 BIT ERROR RATIO (BER) > 1E-1
Meaning
The bit error rate has been exceeded in the input signal.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 201/486
DN998797 201
Transmission Equipment Alarms (8000-8999) 8097 BIT ERROR RATIO (BER) > 1E-1
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 202/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 203/486
DN998797 203
Transmission Equipment Alarms (8000-8999) 8098 BIT ERROR RATIO (BER) > 1E-2
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 204/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 205/486
DN998797 205
Transmission Equipment Alarms (8000-8999) 8099 RECEIVED BIT ERROR RATIO (BER) > 1E-3
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE and Flexi Multiradio:
Description: Received signal has degraded on E1/T1 interface. Bit
Error Ratio (BER) is over 1E-3.
Instructions:
1. If FIFA PIU is used, Refer to the FIFA product documentation
for instructions.
2. Check that the interface settings are correct for the link.
3. Check quality of the E1/T1 line by enabling a Loop to
Interface (line) at the far end equipment. If the alarm is
cancelled during the loop test, check the far-end equipment.
4. Equip an external cable loop to the interface to check that
the interface in FIxx is ok. If the alarm is still active
during the loop test, go to step 6.
5. Check the condition of cables, connectors and correct
polarities of the wire pairs.
6. Check that FIxx is fully inserted in to ESMA.
7. Replace FIxx.
8. Check the signal quality of the transmission path to the
alarming equipment.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 206/486
206 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8100 RECEIVED BIT ERROR RATIO (BER) > 1E-4
93 8100 RECEIVED BIT ERROR RATIO (BER) >
1E-4
Meaning
The bit error rate has been exceeded in the input signal.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 207/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 208/486
208 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8101 RECEIVED BIT ERROR RATIO (BER) > 1E-5
94 8101 RECEIVED BIT ERROR RATIO (BER) >
1E-5
Meaning
The bit error rate has been exceeded in the input signal.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 209/486
DN998797 209
Transmission Equipment Alarms (8000-8999) 8101 RECEIVED BIT ERROR RATIO (BER) > 1E-5
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 210/486
210 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8102 RECEIVED BIT ERROR RATIO (BER) > 1E-6
95 8102 RECEIVED BIT ERROR RATIO (BER) >
1E-6
Meaning
The bit error rate has been exceeded in the input signal.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 211/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 212/486
212 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8103 BIT ERROR RATIO (BER) > 1E-7
96 8103 BIT ERROR RATIO (BER) > 1E-7
Meaning
The bit error rate has been exceeded in the input signal.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 213/486
DN998797 213
Transmission Equipment Alarms (8000-8999) 8103 BIT ERROR RATIO (BER) > 1E-7
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 214/486
214 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8104 BIT ERROR RATIO (BER) > 1E-8
97 8104 BIT ERROR RATIO (BER) > 1E-8
Meaning
The bit error rate has been exceeded in the input signal.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 215/486
DN998797 215
Transmission Equipment Alarms (8000-8999) 8104 BIT ERROR RATIO (BER) > 1E-8
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 216/486
216 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8105 BIT ERROR RATIO (BER) > 1E-9
98 8105 BIT ERROR RATIO (BER) > 1E-9
Meaning
The bit error rate has been exceeded in the input signal.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 217/486
DN998797 217
Transmission Equipment Alarms (8000-8999) 8105 BIT ERROR RATIO (BER) > 1E-9
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 218/486
218 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8106 BIT ERROR RATIO (BER) > 1E-10
99 8106 BIT ERROR RATIO (BER) > 1E-10
Meaning
The bit error rate has been exceeded in the input signal.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 219/486
DN998797 219
Transmission Equipment Alarms (8000-8999) 8106 BIT ERROR RATIO (BER) > 1E-10
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 220/486
220 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8107 BIT ERROR RATIO (BER) > 1E-11
100 8107 BIT ERROR RATIO (BER) > 1E-11
Meaning
The bit error rate has been exceeded in the input signal.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 221/486
DN998797 221
Transmission Equipment Alarms (8000-8999) 8107 BIT ERROR RATIO (BER) > 1E-11
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 222/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 223/486
DN998797 223
Transmission Equipment Alarms (8000-8999) 8108 BIT ERROR RATIO (BER) > 1E-12
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 224/486
224 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8109 FADING IN TRANSMISSION PATH
102 8109 FADING IN TRANSMISSION PATH
Meaning
Fading has been detected in the input signal.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 225/486
DN998797 225
Transmission Equipment Alarms (8000-8999) 8109 FADING IN TRANSMISSION PATH
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 226/486
226 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8110 SELECTIVE FADING IN TRANSMISSION PATH
103 8110 SELECTIVE FADING IN TRANSMISSION
PATH
Meaning
Fading has been detected in the input signal.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 227/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 228/486
228 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8111 MODULATION ERROR
104 8111 MODULATION ERROR
Meaning
A modulation error has been detected in the received signal.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 229/486
DN998797 229
Transmission Equipment Alarms (8000-8999) 8111 MODULATION ERROR
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 230/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 231/486
DN998797 231
Transmission Equipment Alarms (8000-8999) 8112 FREQUENCY ERROR
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE and Flexi Multiradio:
Description: The node is running on the internal clock as
configured in the timing priority list. This alarm can also be raised
in case synchronisation protection is configured, when the Rx source
signals from both directions have its MCBs in state '1' .
Instructions:
1. Check that synchronisation priority list has Rx clock entries
for used interfaces.
2. In case FIFA PIU is used, check that the microwave link is
commissioned and operational. Refer to FIFA product documentation
for further instructions.
3. If any of the alarms 8050, 8066, 8081, 8099, 8056 or 8073 are
active, follow the instructions on them.
4. Check that interface cables are correctly mated to FIxx. Check
also condition of the connectors.
5. If BTS is part of PDH loop protection configuration, check
MCB/LCB configuration and operational state of loop network.
CancellingDo not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 232/486
232 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8113 BUFFER OVERFLOW
106 8113 BUFFER OVERFLOW
Meaning
A frequency error has been detected in the input signal.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 233/486
DN998797 233
Transmission Equipment Alarms (8000-8999) 8113 BUFFER OVERFLOW
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 234/486
234 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8119 SYNCHRONIZING FAULT IN TRANSMITTER
107 8119 SYNCHRONIZING FAULT IN TRANSMIT-
TER
Meaning
A synchronization error has been detected.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 235/486
DN998797 235
Transmission Equipment Alarms (8000-8999) 8119 SYNCHRONIZING FAULT IN TRANSMITTER
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 236/486
236 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8120 SYNCHRONIZING FAULT IN RECEIVER
108 8120 SYNCHRONIZING FAULT IN RECEIVER
Meaning
A synchronization error has been detected.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 237/486
DN998797 237
Transmission Equipment Alarms (8000-8999) 8120 SYNCHRONIZING FAULT IN RECEIVER
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 238/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 239/486
DN998797 239
Transmission Equipment Alarms (8000-8999) 8121 SYNCHRONIZING FAULT IN AUXILIARYCHANNEL
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 240/486
240 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8122 SYNCHRONIZING FAULT
110 8122 SYNCHRONIZING FAULT
Meaning
A synchronization error has been detected.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 241/486
DN998797 241
Transmission Equipment Alarms (8000-8999) 8122 SYNCHRONIZING FAULT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 242/486
242 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8123 SYNCHRONIZING FAULT IN CARRIER RE-COVERY
111 8123 SYNCHRONIZING FAULT IN CARRIER
RECOVERY
Meaning
A synchronization error has been detected.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 243/486
DN998797 243
Transmission Equipment Alarms (8000-8999) 8123 SYNCHRONIZING FAULT IN CARRIER RE-COVERY
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 244/486
244 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8124 SYNCHRONIZATION FAULT IN CLOCK RE-COVERY
112 8124 SYNCHRONIZATION FAULT IN CLOCK
RECOVERY
Meaning
A synchronization error has been detected.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 245/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 246/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 247/486
DN998797 247
Transmission Equipment Alarms (8000-8999) 8125 LOSS OF SYNCHRONIZATION SIGNAL
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: All defined synchronisation sources in the
synchronisation priority list are invalid or the list is empty. Node
is running on its internal clock.
Instructions:
1. Check that synchronisation priority list has Rx clock entries
for used interfaces.
2. In case FIFA PIU is used, check that the microwave link is
commissioned and operational. Refer to FIFA product
documentation for further instructions.
3. If any of the alarms 8050, 8066, 8081, 8099, 8056 or 8073 are
active, follow the instructions on them.
4. Check that interface cables are correctly mated to FIxx. Check
also condition of the connectors.
5. Replace FIxx.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 248/486
248 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8126 UNIT FUNCTION DEGRADED
114 8126 UNIT FUNCTION DEGRADED
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 249/486
DN998797 249
Transmission Equipment Alarms (8000-8999) 8126 UNIT FUNCTION DEGRADED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 250/486
250 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8127 EQUIPMENT FAULT DETECTED IN AUTOMAT-IC LOOP TEST
115 8127 EQUIPMENT FAULT DETECTED IN
AUTOMATIC LOOP TEST
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 251/486
DN998797 251
Transmission Equipment Alarms (8000-8999) 8127 EQUIPMENT FAULT DETECTED IN AUTOMAT-IC LOOP TEST
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 252/486
252 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8128 FAULT IN EQUIPMENT
116 8128 FAULT IN EQUIPMENT
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 253/486
DN998797 253
Transmission Equipment Alarms (8000-8999) 8128 FAULT IN EQUIPMENT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 254/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 255/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 256/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 257/486
DN998797 257
Transmission Equipment Alarms (8000-8999) 8130 FAULT IN MEMORY
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 258/486
258 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8131 INTERNAL BUS FAULT
119 8131 INTERNAL BUS FAULT
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 259/486
DN998797 259
Transmission Equipment Alarms (8000-8999) 8131 INTERNAL BUS FAULT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 260/486
260 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8132 FAULT IN SUMMING UNIT
120 8132 FAULT IN SUMMING UNIT
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 261/486
DN998797 261
Transmission Equipment Alarms (8000-8999) 8132 FAULT IN SUMMING UNIT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 262/486
262 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8133 FAULT IN MUX
121 8133 FAULT IN MUX
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 263/486
DN998797 263
Transmission Equipment Alarms (8000-8999) 8133 FAULT IN MUX
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 264/486
264 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8134 EXCHANGE LINE ALARM
122 8134 EXCHANGE LINE ALARM
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 265/486
DN998797 265
Transmission Equipment Alarms (8000-8999) 8134 EXCHANGE LINE ALARM
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 266/486
266 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8135 EQUIPMENT IN RESET
123 8135 EQUIPMENT IN RESET
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 267/486
DN998797 267
Transmission Equipment Alarms (8000-8999) 8135 EQUIPMENT IN RESET
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 268/486
268 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8136 AIS OSCILLATOR FAULT
124 8136 AIS OSCILLATOR FAULT
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 269/486
DN998797 269
Transmission Equipment Alarms (8000-8999) 8136 AIS OSCILLATOR FAULT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 270/486
270 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8137 OSCILLATOR FAULT
125 8137 OSCILLATOR FAULT
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 271/486
DN998797 271
Transmission Equipment Alarms (8000-8999) 8137 OSCILLATOR FAULT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 272/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 273/486
DN998797 273
Transmission Equipment Alarms (8000-8999) 8138 PRESSURE ALARM
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 274/486
274 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8139 SUBRACK HAS MISSING UNITS
127 8139 SUBRACK HAS MISSING UNITS
Meaning
An installation or usage error has been detected in a piece ofequipment.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 275/486
DN998797 275
Transmission Equipment Alarms (8000-8999) 8139 SUBRACK HAS MISSING UNITS
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 276/486
276 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8140 SUBRACK HAS EXCESSIVE UNITS
128 8140 SUBRACK HAS EXCESSIVE UNITS
Meaning
An installation or usage error has been detected in a piece ofequipment.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 277/486
DN998797 277
Transmission Equipment Alarms (8000-8999) 8140 SUBRACK HAS EXCESSIVE UNITS
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 278/486
278 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8141 FORCED CONTROL ON
129 8141 FORCED CONTROL ON
Meaning
An installation or usage error has been detected in a piece ofequipment.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 279/486
DN998797 279
Transmission Equipment Alarms (8000-8999) 8141 FORCED CONTROL ON
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 280/486
280 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8142 INSTALLATION ERROR
130 8142 INSTALLATION ERROR
Meaning
An installation or usage error has been detected in a piece ofequipment.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 281/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 282/486
282 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8143 FAULT IN CHANGE OVER FUNCTION
131 8143 FAULT IN CHANGE OVER FUNCTION
Meaning
An installation or usage error has been detected in a piece ofequipment.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 283/486
DN998797 283
Transmission Equipment Alarms (8000-8999) 8143 FAULT IN CHANGE OVER FUNCTION
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 284/486
284 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8144 OPERATING ERROR
132 8144 OPERATING ERROR
Meaning
An installation or usage error has been detected in a piece ofequipment.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 285/486
DN998797 285
Transmission Equipment Alarms (8000-8999) 8144 OPERATING ERROR
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 286/486
286 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8145 TEMPERATURE ALARM
133 8145 TEMPERATURE ALARM
Meaning
A piece of equipment has detected an environmental error.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 287/486
DN998797 287
Transmission Equipment Alarms (8000-8999) 8145 TEMPERATURE ALARM
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 288/486
288 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8146 WIND ALARM
134 8146 WIND ALARM
Meaning
A piece of equipment has detected an environmental error.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 289/486
DN998797 289
Transmission Equipment Alarms (8000-8999) 8146 WIND ALARM
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 290/486
290 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8147 LOCAL ALARM CANCEL WITHOUT ANY ALARM
135 8147 LOCAL ALARM CANCEL WITHOUT ANY
ALARM
Meaning
A piece of equipment has detected a usage or operation failure.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 291/486
DN998797 291
Transmission Equipment Alarms (8000-8999) 8147 LOCAL ALARM CANCEL WITHOUT ANY ALARM
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 292/486
292 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8148 EQUIPMENT RESET
136 8148 EQUIPMENT RESET
Meaning
A piece of equipment has detected a usage or operation failure.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 293/486
DN998797 293
Transmission Equipment Alarms (8000-8999) 8148 EQUIPMENT RESET
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: This warning is issued by Q1 device when reset has
occurred.
Instructions:
1. Find out the alarming Q1 device and refer to its product
documentation for more details on this warning message.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 294/486
294 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8149 FORCED INDICATION
137 8149 FORCED INDICATION
Meaning
A piece of equipment has detected a usage or operation failure.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 295/486
DN998797 295
Transmission Equipment Alarms (8000-8999) 8149 FORCED INDICATION
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 296/486
296 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8150 FAULT IN UNIT
138 8150 FAULT IN UNIT
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 297/486
DN998797 297
Transmission Equipment Alarms (8000-8999) 8150 FAULT IN UNIT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 298/486
298 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8151 FAULT IN CHANNEL
139 8151 FAULT IN CHANNEL
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 299/486
DN998797 299
Transmission Equipment Alarms (8000-8999) 8151 FAULT IN CHANNEL
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 300/486
300 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8152 FAULT IN BLOCK
140 8152 FAULT IN BLOCK
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 301/486
DN998797 301
Transmission Equipment Alarms (8000-8999) 8152 FAULT IN BLOCK
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 302/486
302 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8153 FAULT IN TRANSMITTER
141 8153 FAULT IN TRANSMITTER
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 303/486
DN998797 303
Transmission Equipment Alarms (8000-8999) 8153 FAULT IN TRANSMITTER
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 304/486
304 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8154 FAULT IN RECEIVER
142 8154 FAULT IN RECEIVER
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 305/486
DN998797 305
Transmission Equipment Alarms (8000-8999) 8154 FAULT IN RECEIVER
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 306/486
306 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8155 LASER BIAS OUT OF RANGE
143 8155 LASER BIAS OUT OF RANGE
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 307/486
DN998797 307
Transmission Equipment Alarms (8000-8999) 8155 LASER BIAS OUT OF RANGE
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 308/486
308 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8156 LASER POWER OUT OF RANGE
144 8156 LASER POWER OUT OF RANGE
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 309/486
DN998797 309
Transmission Equipment Alarms (8000-8999) 8156 LASER POWER OUT OF RANGE
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 310/486
310 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8157 LASER TEMPERATURE OUT OF RANGE
145 8157 LASER TEMPERATURE OUT OF
RANGE
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 311/486
DN998797 311
Transmission Equipment Alarms (8000-8999) 8157 LASER TEMPERATURE OUT OF RANGE
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 312/486
312 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8158 FORCED LASER CUT OFF
146 8158 FORCED LASER CUT OFF
Meaning
A piece of equipment has detected a fault in its operation.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 313/486
DN998797 313
Transmission Equipment Alarms (8000-8999) 8158 FORCED LASER CUT OFF
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 314/486
314 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8159 RUN DIAGNOSTICS TEST
147 8159 RUN DIAGNOSTICS TEST
Meaning
The equipment has detected a fault in a diagnostics test.This alarm affects the provided services. The unit may not be working
properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 315/486
DN998797 315
Transmission Equipment Alarms (8000-8999) 8159 RUN DIAGNOSTICS TEST
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 316/486
316 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8160 INTERFACE UNIT FAULT
148 8160 INTERFACE UNIT FAULT
Meaning
A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be
working properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 317/486
DN998797 317
Transmission Equipment Alarms (8000-8999) 8160 INTERFACE UNIT FAULT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 318/486
318 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8161 CONNECTED TO REDUNDANT SYSTEM
149 8161 CONNECTED TO REDUNDANT SYSTEM
Meaning
A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be
working properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 319/486
DN998797 319
Transmission Equipment Alarms (8000-8999) 8161 CONNECTED TO REDUNDANT SYSTEM
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 320/486
320 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8162 DATABASE FULL
150 8162 DATABASE FULL
Meaning
A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be
working properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 321/486
DN998797 321
Transmission Equipment Alarms (8000-8999) 8162 DATABASE FULL
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: This warning is sent when the polling master
(BTS/BSC) is either unable to poll alarms from the Q1 device(s)
or it has not cleared the alarm history. Alarm history database has
become full.
Instructions:
1. Find out the alarming Q1 device and refer to its product
documentation for more details on this warning message.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 322/486
322 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8163 REDUNDANT CONNECTION IN USE
151 8163 REDUNDANT CONNECTION IN USE
Meaning
A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be
working properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 323/486
DN998797 323
Transmission Equipment Alarms (8000-8999) 8163 REDUNDANT CONNECTION IN USE
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 324/486
324 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8164 LINE CABLE FAULT
152 8164 LINE CABLE FAULT
Meaning
A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be
working properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 325/486
DN998797 325
Transmission Equipment Alarms (8000-8999) 8164 LINE CABLE FAULT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 326/486
326 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8165 REAL TIME LOST
153 8165 REAL TIME LOST
Meaning
A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be
working properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 327/486
DN998797 327
Transmission Equipment Alarms (8000-8999) 8165 REAL TIME LOST
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: Q1 device has not received real time from the polling
master (BTS/BSC). Time stamps are not displayed correctly.
Instructions:
1. Find out the alarming Q1 device and refer to its product
documentation for more details on this alarm.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 328/486
328 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8166 E1 CONVERTER RESET
154 8166 E1 CONVERTER RESET
Meaning
A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be
working properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 329/486
DN998797 329
Transmission Equipment Alarms (8000-8999) 8166 E1 CONVERTER RESET
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 330/486
330 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8167 E1 CONVERTER FAULT
155 8167 E1 CONVERTER FAULT
Meaning
A piece of equipment has detected a fault in its operation.This alarm may affect the provided services. The unit may not be
working properly.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 331/486
DN998797 331
Transmission Equipment Alarms (8000-8999) 8167 E1 CONVERTER FAULT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 332/486
332 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8168 EQUIPMENT DOOR OPEN
156 8168 EQUIPMENT DOOR OPEN
Meaning
A piece of equipment has detected a fault in its operation.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 333/486
DN998797 333
Transmission Equipment Alarms (8000-8999) 8168 EQUIPMENT DOOR OPEN
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 334/486
334 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8169 EXTENDED FAULT CODE IN USE
157 8169 EXTENDED FAULT CODE IN USE
Meaning
The BSC or BTS does not recognise the received fault code. Theequipment is supervised by the TMS4 polling system and does not
understand the extended fault codes.
This alarm may affect the provided services depending on the
actual fault.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 335/486
DN998797 335
Transmission Equipment Alarms (8000-8999) 8169 EXTENDED FAULT CODE IN USE
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 336/486
336 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8172 YELLOW ALARM OCCURRED
158 8172 YELLOW ALARM OCCURRED
Meaning
The yellow alarm is sent by the equipment in the far-end, itindicates a serious fault in the received signal of the far-end
equipment.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 337/486
DN998797 337
Transmission Equipment Alarms (8000-8999) 8172 YELLOW ALARM OCCURRED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Instructions:
1. Check the far end equipment for alarms 8056, 8073, 8081.
See the instructions on them.
2. Apply Loop to interface (line) at far end to check that link
is ok. If 8056/8073/8081 alarm is not active at near-end
during the loop test the problem is at the far-end receiver.
Note: 8172 Yellow alarm will be cancelled during this test.
3. Equip an external cable loop to the interface to check that
the interface in FIxx is ok. If 8056/8073/8081 alarm is active
during the loop test, go to step 5. Note: 8172 Yellow alarm
will be cancelled during this test.
4. Check the condition of cables, connectors and correct
polarities of the wire pairs.
5. Check that FIxx is fully inserted in to ESMA.
6. Replace FIxx.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.
Flexi EDGE:
Do not cancel the alarm. The alarm is cancelled automatically when Yellow
alarm (RAI) clearance is detected according to ANSI T1.231.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 338/486
338 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8173 FAR-END ALARM 4
159 8173 FAR-END ALARM 4
Meaning
A piece of transmission equipment has received a far-end alarm.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 339/486
DN998797 339
Transmission Equipment Alarms (8000-8999) 8173 FAR-END ALARM 4
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 340/486
340 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8174 FAR-END ALARM 3
160 8174 FAR-END ALARM 3
Meaning
A piece of transmission equipment has received a far-end alarm.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 341/486
DN998797 341
Transmission Equipment Alarms (8000-8999) 8174 FAR-END ALARM 3
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 342/486
342 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8175 FAR-END ALARM 2
161 8175 FAR-END ALARM 2
Meaning
A piece of transmission equipment has received a far-end alarm.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 343/486
DN998797 343
Transmission Equipment Alarms (8000-8999) 8175 FAR-END ALARM 2
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 344/486
344 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8176 FAR-END ALARM RECEIVED
162 8176 FAR-END ALARM RECEIVED
Meaning
A piece of transmission equipment has received a far-end alarm.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 345/486
DN998797 345
Transmission Equipment Alarms (8000-8999) 8176 FAR-END ALARM RECEIVED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 346/486
346 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8178 MULTIFRAME ALARM FROM FAR-END
163 8178 MULTIFRAME ALARM FROM FAR-END
Meaning
A piece of transmission equipment has received a far-end alarm.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 347/486
DN998797 347
Transmission Equipment Alarms (8000-8999) 8178 MULTIFRAME ALARM FROM FAR-END
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 348/486
348 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8179 FAR-END ALARM
164 8179 FAR-END ALARM
Meaning
Sent by the equipment in the far-end (TS0 Bit 3), which indicatesthat far-end equipment is unable to receive the signal.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 349/486
DN998797 349
Transmission Equipment Alarms (8000-8999) 8179 FAR-END ALARM
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Instructions:
1. Check the far end equipment for alarms 8050, 8066, 8081
and 8086. See the instructions on them.
2. Apply Loop to interface (line) at far end to check that link
is ok. If 8050/8066/8081/8086 alarm is not active at near-end
during the loop test the problem is at the far-end receiver.
Note: 8179 Far-end alarm will be cancelled during this test.
3. Equip an external cable loop to the interface to check that
the interface in FIxx is ok. If 8050/8066/8081/8086 alarm
is active during the loop test, go to step 5.
Note: 8179 Far-end alarm will be cancelled during this test.
4. Check the condition of cables, connectors and correct
polarities of the wire pairs.
5. Check that FIxx is fully inserted in to ESMA.
6. Replace FIxx.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 350/486
350 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8180 ALARM FROM FAR-END SUBSYSTEM
165 8180 ALARM FROM FAR-END SUBSYSTEM
Meaning
A piece of transmission equipment has received a far-end alarm.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 351/486
DN998797 351
Transmission Equipment Alarms (8000-8999) 8180 ALARM FROM FAR-END SUBSYSTEM
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 352/486
352 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8181 FAR-END SENDING FAULT
166 8181 FAR-END SENDING FAULT
Meaning
A piece of transmission equipment has received a far-end alarm.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 353/486
DN998797 353
Transmission Equipment Alarms (8000-8999) 8181 FAR-END SENDING FAULT
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 354/486
354 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8182 FAULT IN FAR-END RECEIVING
167 8182 FAULT IN FAR-END RECEIVING
Meaning
A piece of transmission equipment has received a far-end alarm.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 355/486
DN998797 355
Transmission Equipment Alarms (8000-8999) 8182 FAULT IN FAR-END RECEIVING
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 356/486
356 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8183 FAR-END SYNCHRONIZATION ALARM
168 8183 FAR-END SYNCHRONIZATION ALARM
Meaning
A piece of transmission equipment has received a far-end alarm.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 357/486
DN998797 357
Transmission Equipment Alarms (8000-8999) 8183 FAR-END SYNCHRONIZATION ALARM
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 358/486
358 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8184 REAL TIME UPDATED
169 8184 REAL TIME UPDATED
Meaning
Real time is updated to the equipment. The equipment's time changeexceeds the alarm threshold.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 359/486
DN998797 359
Transmission Equipment Alarms (8000-8999) 8184 REAL TIME UPDATED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
This alarm does not require any action. The system has updated
the equipment time more than the alarm threshold.
See the equipment operating manual for more detailed information on
the fault code.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 360/486
360 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8185 CONNECTION OR SETTINGS HAVECHANGED
170 8185 CONNECTION OR SETTINGS HAVE
CHANGED
Meaning
Connection or settings have changed in a piece of transmission
equipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 361/486
DN998797 361
Transmission Equipment Alarms (8000-8999) 8185 CONNECTION OR SETTINGS HAVECHANGED
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 362/486
362 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8186 CONFIGURATION ERROR
171 8186 CONFIGURATION ERROR
Meaning
A configuration error has been detected in a piece of equipment.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 363/486
DN998797 363
Transmission Equipment Alarms (8000-8999) 8186 CONFIGURATION ERROR
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 364/486
364 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8190 CUSTOMER SPECIFIC FAULT CODE 1
172 8190 CUSTOMER SPECIFIC FAULT CODE 1
Meaning
This alarm is generated from a customer specific fault code.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 365/486
DN998797 365
Transmission Equipment Alarms (8000-8999) 8190 CUSTOMER SPECIFIC FAULT CODE 1
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 366/486
366 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8191 CUSTOMER SPECIFIC FAULT CODE 2
173 8191 CUSTOMER SPECIFIC FAULT CODE 2
Meaning
This alarm is generated from a customer specific fault code.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 367/486
DN998797 367
Transmission Equipment Alarms (8000-8999) 8191 CUSTOMER SPECIFIC FAULT CODE 2
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 368/486
368 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8192 CUSTOMER SPECIFIC FAULT CODE 3
174 8192 CUSTOMER SPECIFIC FAULT CODE 3
Meaning
This alarm is generated from a customer specific fault code.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 369/486
DN998797 369
Transmission Equipment Alarms (8000-8999) 8192 CUSTOMER SPECIFIC FAULT CODE 3
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 370/486
370 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8193 CUSTOMER SPECIFIC FAULT CODE 4
175 8193 CUSTOMER SPECIFIC FAULT CODE 4
Meaning
This alarm is generated from a customer specific fault code.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 371/486
DN998797 371
Transmission Equipment Alarms (8000-8999) 8193 CUSTOMER SPECIFIC FAULT CODE 4
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 372/486
372 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8194 CUSTOMER SPECIFIC FAULT CODE 5
176 8194 CUSTOMER SPECIFIC FAULT CODE 5
Meaning
This alarm is generated from a customer specific fault code.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 373/486
DN998797 373
Transmission Equipment Alarms (8000-8999) 8194 CUSTOMER SPECIFIC FAULT CODE 5
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 374/486
374 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8195 V5 PROTOCOL ALARM
177 8195 V5 PROTOCOL ALARM
Meaning
This alarm is generated from a customer specific fault code.
This alarm may affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 375/486
DN998797 375
Transmission Equipment Alarms (8000-8999) 8195 V5 PROTOCOL ALARM
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 376/486
376 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8200 LOSS OF PRIMARY SUPERVISION CONNEC-TION
178 8200 LOSS OF PRIMARY SUPERVISION
CONNECTION
Meaning
A piece of equipment has detected a supervision connection fault.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 377/486
DN998797 377
Transmission Equipment Alarms (8000-8999) 8200 LOSS OF PRIMARY SUPERVISION CONNEC-TION
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 378/486
378 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8201 LOSS OF SECONDARY SUPERVISION CON-NECTION
179 8201 LOSS OF SECONDARY SUPERVISION
CONNECTION
Meaning
A piece of equipment has detected a supervision connection fault.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 379/486
DN998797 379
Transmission Equipment Alarms (8000-8999) 8201 LOSS OF SECONDARY SUPERVISION CON-NECTION
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 380/486
380 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8202 LOSS OF SUPERVISION CONNECTION
180 8202 LOSS OF SUPERVISION CONNECTION
Meaning
A piece of equipment has detected a supervision connection fault.This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 381/486
DN998797 381
Transmission Equipment Alarms (8000-8999) 8202 LOSS OF SUPERVISION CONNECTION
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: Q1 device doesn't respond to poll command sent by the
polling master (BTS/BSC).
Instructions:
1. Check that Q1 baud rate and Q1 address of the Q1 device matches
with what is configured at the BSC.
2. Check if alarm 7601 "Q1 bus faulty" is active. Check that the
cable is correctly mated with the ESMA and Q1 device. Check also
condition of the Q1 cable connectors.
3. Check that Q1 switches are set to enable polling master (BTS/BSC)
to access the microprocessor (up) of the Q1 device.
4. Replace ESMA.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 382/486
382 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8203 LOSS OF SUPERVISION BUS
181 8203 LOSS OF SUPERVISION BUS
Meaning
A piece of equipment has detected a supervision connection fault.This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 383/486
DN998797 383
Transmission Equipment Alarms (8000-8999) 8203 LOSS OF SUPERVISION BUS
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 384/486
384 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8206 CONGESTION
182 8206 CONGESTION
Meaning
There is congestion in the equipment or in the plug-in unit. Resource orservice has congestion and requested operation cannot be executed.
This alarm affects the provided services. The unit is not working
properly and the unit services may be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If the equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 385/486
DN998797 385
Transmission Equipment Alarms (8000-8999) 8206 CONGESTION
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 386/486
386 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8207 CALIBRATION EXPIRED
183 8207 CALIBRATION EXPIRED
Meaning
Recalibration is needed.
This alarm may affect the provided services. The unit is not working
properly and the unit services may be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 387/486
DN998797 387
Transmission Equipment Alarms (8000-8999) 8207 CALIBRATION EXPIRED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 388/486
388 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8213 REMOTE DEFECT INDICATION (RDI)
184 8213 REMOTE DEFECT INDICATION (RDI)
Meaning
A remote end indicates failure in the termination point.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 389/486
DN998797 389
Transmission Equipment Alarms (8000-8999) 8213 REMOTE DEFECT INDICATION (RDI)
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 390/486
390 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8214 SIGNAL DEGRADED
185 8214 SIGNAL DEGRADED
Meaning
The signal is degraded.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 391/486
DN998797 391
Transmission Equipment Alarms (8000-8999) 8214 SIGNAL DEGRADED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 392/486
392 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8215 TRACE IDENTIFIER MISMATCH
186 8215 TRACE IDENTIFIER MISMATCH
Meaning
The trace identifier does not match the expected one.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 393/486
DN998797 393
Transmission Equipment Alarms (8000-8999) 8215 TRACE IDENTIFIER MISMATCH
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 394/486
394 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8216 UNEQUIPPED SIGNAL
187 8216 UNEQUIPPED SIGNAL
Meaning
Virtual Container (VC) does not carry valid payload data because thecross-connection is not configured.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 395/486
DN998797 395
Transmission Equipment Alarms (8000-8999) 8216 UNEQUIPPED SIGNAL
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 396/486
396 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8221 VERSION MISMATCH
188 8221 VERSION MISMATCH
Meaning
The software or program version is not compatible with the hardware,other software versions or software information.
This alarm affects the provided services. The unit is not working
properly and the unit services may be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 397/486
DN998797 397
Transmission Equipment Alarms (8000-8999) 8221 VERSION MISMATCH
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 398/486
398 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8222 CORRUPT DATA
189 8222 CORRUPT DATA
Meaning
The received or stored data is corrupted. The data content is notwhat it was expected to be.
This alarm affects the provided services. The unit is not working
properly and the unit services may be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 399/486
DN998797 399
Transmission Equipment Alarms (8000-8999) 8222 CORRUPT DATA
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 400/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 401/486
DN998797 401
Transmission Equipment Alarms (8000-8999) 8223 PROTECTION SWITCH
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 402/486
402 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8230 THRESHOLD CROSSED
191 8230 THRESHOLD CROSSED
Meaning
A piece of equipment has detected a performance monitoring fault.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 ascii string of the piece of transmission equipment type.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 403/486
DN998797 403
Transmission Equipment Alarms (8000-8999) 8230 THRESHOLD CROSSED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 404/486
404 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8240 ACTIVE ALARM POINT
192 8240 ACTIVE ALARM POINT
Meaning
This is an external alarm connected to a piece of transmissionequipment.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 405/486
DN998797 405
Transmission Equipment Alarms (8000-8999) 8240 ACTIVE ALARM POINT
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Flexi EDGE:
Description: This is an external user-defined alarm. This alarm is
activated at the external equipment. Alarrm line number is mapped to
Supervision Block number. EAC lines can be routed via EAC port at ESMA
or via FSEx connected to ESMA.
Instructions:
1. Check that the relevant EAC line is correctly configured at the
BSC (MML command ZEFO:<id>:IOP;).
2. Check equipment connected to alarming EAC line.
3. Check that the cable chain is correctly mated between ESMA and
the external equipment.
4. Check the ESMA and replace it if faulty.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 406/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 407/486
DN998797 407
Transmission Equipment Alarms (8000-8999) 8241 UPPER ALARM LIMIT EXCEEDED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 408/486
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 409/486
DN998797 409
Transmission Equipment Alarms (8000-8999) 8242 LOWER ALARM LIMIT EXCEEDED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 410/486
410 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8250 INVALID TIME
195 8250 INVALID TIME
Meaning
This is a transmission equipment alarm generated by a mediator device.The mediator has detected that the time in the alarm is in the future
or too far away in the past.
This alarm affects the provided services. The unit is not working
properly and the unit services may be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 411/486
DN998797 411
Transmission Equipment Alarms (8000-8999) 8250 INVALID TIME
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session totransmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 412/486
412 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8254 OPERATOR DISABLED
196 8254 OPERATOR DISABLED
Meaning
This is a transmission equipment alarm generated by a mediator device.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 413/486
DN998797 413
Transmission Equipment Alarms (8000-8999) 8254 OPERATOR DISABLED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 414/486
414 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8256 15 MIN G826 ES THRESHOLD CROSSED
197 8256 15 MIN G826 ES THRESHOLD
CROSSED
Meaning
A piece of equipment has detected a performance monitoring fault.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 415/486
DN998797 415
Transmission Equipment Alarms (8000-8999) 8256 15 MIN G826 ES THRESHOLD CROSSED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 416/486
416 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8257 15 MIN G826 SES THRESHOLD CROSSED
198 8257 15 MIN G826 SES THRESHOLD
CROSSED
Meaning
A piece of equipment has detected a performance monitoring fault.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 417/486
DN998797 417
Transmission Equipment Alarms (8000-8999) 8257 15 MIN G826 SES THRESHOLD CROSSED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 418/486
418 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8258 15 MIN G826 BBE THRESHOLD CROSSED
199 8258 15 MIN G826 BBE THRESHOLD
CROSSED
Meaning
A piece of equipment has detected a performance monitoring fault.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 419/486
DN998797 419
Transmission Equipment Alarms (8000-8999) 8258 15 MIN G826 BBE THRESHOLD CROSSED
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 420/486
420 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8259 24 H G826 ES THRESHOLD CROSSED
200 8259 24 H G826 ES THRESHOLD CROSSED
Meaning
A piece of equipment has detected a performance monitoring fault.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 421/486
DN998797 421
Transmission Equipment Alarms (8000-8999) 8259 24 H G826 ES THRESHOLD CROSSED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 422/486
422 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8260 24 H G826 SES THRESHOLD CROSSED
201 8260 24 H G826 SES THRESHOLD CROSSED
Meaning
A piece of equipment has detected a performance monitoring fault.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 423/486
DN998797 423
Transmission Equipment Alarms (8000-8999) 8260 24 H G826 SES THRESHOLD CROSSED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 424/486
424 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8261 24 H G826 BBE THRESHOLD CROSSED
202 8261 24 H G826 BBE THRESHOLD CROSSED
Meaning
A piece of equipment has detected a performance monitoring fault.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 425/486
DN998797 425
Transmission Equipment Alarms (8000-8999) 8261 24 H G826 BBE THRESHOLD CROSSED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 426/486
426 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8262 STATISTIC UNAVAILABILITY
203 8262 STATISTIC UNAVAILABILITY
Meaning
A piece of equipment has detected a performance monitoring fault.
This alarm does not affect the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 427/486
DN998797 427
Transmission Equipment Alarms (8000-8999) 8262 STATISTIC UNAVAILABILITY
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 428/486
428 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8263 STATISTIC RESET
204 8263 STATISTIC RESET
Meaning
A piece of equipment has detected a performance monitoring fault.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 429/486
DN998797 429
Transmission Equipment Alarms (8000-8999) 8263 STATISTIC RESET
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 430/486
430 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8264 15 MIN T/RLTS THRESHOLD CROSSED
205 8264 15 MIN T/RLTS THRESHOLD CROSSED
Meaning
In the radio interface a T/RLTS is a one-second period during whichthe detected transmitted level (TL) value is higher or the received
level (RL) value is lower than a predefined reference threshold.
If the number of seconds counted in a time interval is higher than
the predefined threshold value, this event is generated.
This alarm affects the provided services. The unit is not working
properly and the unit services may be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 431/486
DN998797 431
Transmission Equipment Alarms (8000-8999) 8264 15 MIN T/RLTS THRESHOLD CROSSED
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 432/486
432 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8265 24 H T/RLTS THRESHOLD CROSSED
206 8265 24 H T/RLTS THRESHOLD CROSSED
Meaning
In the radio interface a T/RLTS is a one-second period during whichthe detected transmitted level (TL) value is higher or the received
level (RL) value is lower than a predefined reference threshold.
If the number of seconds counted in a time interval is higher than
a predefined threshold value, this event is generated.
This alarm affects the provided services. The unit is not working
properly and the unit services may be lost.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 433/486
DN998797 433
Transmission Equipment Alarms (8000-8999) 8265 24 H T/RLTS THRESHOLD CROSSED
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
No cancelling.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 434/486
434 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8266 LICENCE KEY NOT VALID
207 8266 LICENCE KEY NOT VALID
Meaning
The licence key does not fit the unit or the feature.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 435/486
DN998797 435
Transmission Equipment Alarms (8000-8999) 8266 LICENCE KEY NOT VALID
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 436/486
436 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8267 LICENCE EXPIRED
208 8267 LICENCE EXPIRED
Meaning
Licence has expired. The feature has been deactivated.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 437/486
DN998797 437
Transmission Equipment Alarms (8000-8999) 8267 LICENCE EXPIRED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 438/486
438 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8268 LICENCE WILL EXPIRE IN THE NEAR FUTURE
209 8268 LICENCE WILL EXPIRE IN THE NEAR
FUTURE
Meaning
The licence is time limited. The feature will not be usable after
licence expiration.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 439/486
DN998797 439
Transmission Equipment Alarms (8000-8999) 8268 LICENCE WILL EXPIRE IN THE NEAR FUTURE
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 440/486
440 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8269 LICENCE FOR FEATURE IS NOT AVAILABLE
210 8269 LICENCE FOR FEATURE IS NOT AVAIL-
ABLE
Meaning
The feature cannot be activated without a licence.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 441/486
DN998797 441
Transmission Equipment Alarms (8000-8999) 8269 LICENCE FOR FEATURE IS NOT AVAILABLE
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 442/486
442 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8270 LICENCE FOR FEATURE HAS BEEN ACTIVAT-ED
211 8270 LICENCE FOR FEATURE HAS BEEN
ACTIVATED
Meaning
The user has activated the licence for the feature.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 443/486
DN998797 443
Transmission Equipment Alarms (8000-8999) 8270 LICENCE FOR FEATURE HAS BEEN ACTIVAT-ED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 444/486
444 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8271 LICENCE FOR FEATURE HAS BEEN DEACTI-VATED
212 8271 LICENCE FOR FEATURE HAS BEEN
DEACTIVATED
Meaning
The user has deactivated the licence for the feature.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 445/486
DN998797 445
Transmission Equipment Alarms (8000-8999) 8271 LICENCE FOR FEATURE HAS BEEN DEACTI-VATED
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 446/486
446 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8272 POSITION NOT LOCKED
213 8272 POSITION NOT LOCKED
Meaning
The global positioning system (GPS) position is not locked becausea GPS receiver self survey is ongoing. The location measurement unit(LMU)
GPS position is not locked. A minimum of four satellite signals are
needed to achieve GPS FIX.
The GPS position survey takes about 24 hours with a good satellite view.
If the self survey is not completed within a reasonable time(it may take
from one to five days), check the GPS antenna installation.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies the physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 the number of the Q1 service channel in the BSC. The number can
be 0...27. If the equipment is supervised by the BTS, the channel
number is not relevant
6 the name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
7 the number of the piece of transmission equipment.
Not included if the index is in the alarm object field of the alarm printout.
For more information, see the alarm's instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 447/486
DN998797 447
Transmission Equipment Alarms (8000-8999) 8272 POSITION NOT LOCKED
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check the Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, open a remote session to the
transmission equipment and display the fault information.
For more detailed information on the fault code and corrective actions,
see the equipment's operating manual.
Flexi EDGE:
Description: The LMUB power is out of its normal operating limits or the
fuse-link is blown due to over-current.
Instructions:
Refer to the Location Measurement Unit (LMUB) product documentation for
troubleshooting information.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 448/486
448 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8273 LICENCE FOR 2G FLEXI ABIS OVER IP/ETH-ERNET IS NOT AVAILABLE
214 8273 LICENCE FOR 2G FLEXI ABIS OVER
IP/ETHERNET IS NOT AVAILABLE
Meaning
The feature cannot be activated without a licence.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies the physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 the number of the Q1 service channel in the BSC, 0...27.
If the equipment is supervised by the BTS, the channel number
is not relevant
6 the name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 449/486
DN998797 449
Transmission Equipment Alarms (8000-8999) 8273 LICENCE FOR 2G FLEXI ABIS OVER IP/ETH-ERNET IS NOT AVAILABLE
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check the Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, open a remote session to the
transmission equipment and display the fault information.
For more detailed information on the fault code and corrective actions,
see the equipment's operating manual.
Flexi EDGE and Flexi Multiradio:
Description: Transmission is commissioned to be in Pseudowire
(PWE) mode without a licence or without configuring the BSC.
Instructions:
1. Check the status of the '2G Flexi Abis over IP/
Ethernet' feature at the BSC, and if needed, install
and/or activate it.
2. Configure the '2G Flexi Abis over IP/Ethernet' feature
in the BSC.
Alternatively, you can:
1. Recommission the site to use TDM mode.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 450/486
450 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8274 LICENCE FOR 2G FLEXI ADDITIONAL 2 E1/T1IS NOT AVAILABLE
215 8274 LICENCE FOR 2G FLEXI ADDITIONAL 2
E1/T1 IS NOT AVAILABLE
Meaning
The feature cannot be activated without a licence.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies the physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 the number of the Q1 service channel in the BSC, 0...27.
If the equipment is supervised by the BTS, the channel number
is not relevant
6 the name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 451/486
DN998797 451
Transmission Equipment Alarms (8000-8999) 8274 LICENCE FOR 2G FLEXI ADDITIONAL 2 E1/T1IS NOT AVAILABLE
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check the Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, open a remote session to
the transmission equipment and display the fault information.
For more detailed information on the fault code and corrective actions,
see the equipment's operating manual.
Flexi EDGE and Flexi Multiradio:
Description: The number of used E1/T1 interfaces with terminated
Abis traffic is higher than the number of licensed E1/T1 interfaces
or the number of the E1/T1 interfaces configured in the BSC.
Instructions:
1. Check the status of the '2G Flexi Additional 2 E1/T1'
feature at the BSC, and if needed, install and/or activate
it.
2. Configure the '2G Flexi Additional 2 E1/T1' feature by
increasing the number of licensed E1/T1 interfaces at the
BSC.
Alternatively, you can:
1. Reduce the number of E1/T1 interfaces exceeding the licence:
a. Remove the terminated Abis allocations from the number of
exceeded interfaces.
OR
b. Set the exceeded number of interfaces to 'Not in Use'
state.
Note: Only two E1/T1 interfaces are licence free. One licence will
increase the number of E1/T1 interfaces by two.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 452/486
452 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8275 LICENCE FOR 2G FLEXI ABIS TRS GROOM-ING IS NOT AVAILABLE
216 8275 LICENCE FOR 2G FLEXI ABIS TRS
GROOMING IS NOT AVAILABLE
Meaning
The feature cannot be activated without a licence.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies the physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 the number of the Q1 service channel in the BSC, 0...27.
If the equipment is supervised by the BTS, the channel number
is not relevant
6 the name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 453/486
DN998797 453
Transmission Equipment Alarms (8000-8999) 8275 LICENCE FOR 2G FLEXI ABIS TRS GROOM-ING IS NOT AVAILABLE
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check the Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, open a remote session to
the transmission equipment and display the fault information.
For more detailed information on the fault code and corrective actions,
see the equipment's operating manual.
Flexi EDGE and Flexi Multiradio:
Description: Bypass cross-connections are configured in used E1/T1
interfaces without a licence or without configuring the BSC.
Instructions:
1. Check the status of the '2G Flexi Abis TRS Grooming'
feature at the BSC, and if needed, install and/or activate
it.
2. Configure the '2G Flexi Abis TRS Grooming' feature
in the BSC.
Alternatively, you can:
1. Disable all the cross-connections which are controlled by
'2G Flexi Abis TRS Grooming'.
Note: Bi-directional cross-connections controlled by '2G Flexi Abis
TRS Grooming' are of the following granularities: 8 kBit/s,
16 kBit/s, 32 kBit/s, 64 kBit/s and n*64 kBit/s.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 454/486
454 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8276 LICENCE FOR 2G FLEXI TRS LOOP PROTEC-TION IS NOT AVAILABLE
217 8276 LICENCE FOR 2G FLEXI TRS LOOP
PROTECTION IS NOT AVAILABLE
Meaning
The feature cannot be activated without a licence.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies the physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 the number of the Q1 service channel in the BSC, 0...27.
If the equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 455/486
DN998797 455
Transmission Equipment Alarms (8000-8999) 8276 LICENCE FOR 2G FLEXI TRS LOOP PROTEC-TION IS NOT AVAILABLE
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check the Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, open a remote session to the
transmission equipment and display the fault information.
For more detailed information on the fault code and corrective actions,
see the equipment's operating manual.
Flexi EDGE and Flexi Multiradio:
Description: Abis protection and/or protected cross-connections are
configured in used E1/T1 interfaces without a licence or without
configuring the BSC.
Instructions:
1. Check the status of the '2G Flexi TRS Loop Protection'
feature at the BSC, and if needed, install and/or activate
it.
2. Configure the '2G Flexi TRS Loop Protection' feature in
the BSC.
Alternatively, you can:
1. Disable all cross-connections which are controlled by
'2G Flexi TRS Loop Protection'.
Note: Protected bi-directional cross-connections, Masked
bi-directional cross-connections and Abis protection are
controlled by '2G Flexi TRS Loop Protection'.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically whenthe fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 456/486
456 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8277 ETHERNET PHYSICAL LINK LAYER LOST
218 8277 ETHERNET PHYSICAL LINK LAYER
LOST
Meaning
Incoming ethernet link connectivity is lost because of a broken or
missing cable, loose connector, or high attenuation on ethernet link.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies the physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 the number of the Q1 service channel in the BSC. The number can
be 0...27. If the equipment is supervised by the BTS, the channel number is not relevant
6 the name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
7 the number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 457/486
DN998797 457
Transmission Equipment Alarms (8000-8999) 8277 ETHERNET PHYSICAL LINK LAYER LOST
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check the Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, open a remote session to the
transmission equipment and display the fault information.
For more detailed information on the fault code and corrective actions,
see the equipment's operating manual.
Flexi EDGE and Flexi Multiradio:
Description: Physical Ethernet link is detected to be down.
Instructions:
1. Check that the Ethernet cable is connected to the right interface and
the cable is correctly mated to the PIU. Check the condition of
cables and connectors. Check that the length/type of the cable does not
introduce excessive attenuation.
2. Check that the device connected to the FIxx PIU supports 100 Base-T,
full duplex mode and autonegotiation.
3. Check that the device connected to the FIxx PIU has correct settings,
such as autonegotiation and Ethernet interface enabled.
4. Replace FIxx.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 458/486
458 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8278 PSEUDOWIRE DOWN
219 8278 PSEUDOWIRE DOWN
Meaning
Pseudowire connection is lost. There is a configuration mismatch ofpseudowire (PW) parameters between pseudowire emulation edge to edge
(PWE) near and far end, or a cut in connection in the packet switched
network because of a link/equipment defect or very high congestion.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies the physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 the number of the Q1 service channel in the BSC. The number can
be 0...27. If the equipment is supervised by the BTS, the channel
number is not relevant
6 the name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
7 the number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 459/486
DN998797 459
Transmission Equipment Alarms (8000-8999) 8278 PSEUDOWIRE DOWN
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check the Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, open a remote session to thetransmission equipment and display the fault information.
For more detailed information on the fault code and corrective actions,
see the equipment's operating manual.
Flexi EDGE and Flexi Multiradio:
Description: The incoming pseudowire connection is down. There is a fault
in the connection of the pseudowire. R bit is set at the CESoPSN control
word and sent in the Tx direction.
Instructions:
1. Check the pseudowire and pseudowire tunnel configuration settings at
both ends.
2. Check the conditions in the transmission path of the pseudowire tunnel
at the packet switched network.
3. Replace FIxx.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 460/486
460 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8279 PSEUDOWIRE PERFORMANCE DEGRADED
220 8279 PSEUDOWIRE PERFORMANCE
DEGRADED
Meaning
The performance of pseudowire is below the threshold. There is high
delay, delay variation, or excessive packet loss because of high load
in the packet switched network. The jitter buffer size is insufficient.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies the physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 the number of the Q1 service channel in the BSC. The number can be 0...27. If the equipment is supervised by the BTS, the channel
number is not relevant
6 the name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
7 the number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 461/486
DN998797 461
Transmission Equipment Alarms (8000-8999) 8279 PSEUDOWIRE PERFORMANCE DEGRADED
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check the Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, open a remote session to thetransmission equipment and display the fault information.
For more detailed information on the fault code and corrective actions,
see the equipment's operating manual.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 462/486
462 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8280 PSEUDOWIRE REMOTE PACKET LOSS
221 8280 PSEUDOWIRE REMOTE PACKET LOSS
Meaning
The far-end pseudowire emulation edge to edge (PWE) equipment signalsare defect in the received pseudowire (PW) signal of the far-end PWE
equipment. There is a PW parameter configuration mismatch between the
PWE near and far end, a unidirectional cut in connection in the packet
switched network because of a link/equipment defect, or very high
congestion.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies the physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 the number of the Q1 service channel in the BSC. The number can
be 0...27. If the equipment is supervised by the BTS, the channel
number is not relevant
6 the name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
7 the number of the piece of transmission equipment.
Not included if the index is in the alarm object field of the alarm printout.
For more information, see the alarm's instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 463/486
DN998797 463
Transmission Equipment Alarms (8000-8999) 8280 PSEUDOWIRE REMOTE PACKET LOSS
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check the Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, open a remote session to the
transmission equipment and display the fault information.
For more detailed information on the fault code and corrective actions,
see the equipment's operating manual.
Flexi EDGE and Flexi Multiradio:
Description: Signalled by the equipment in the far-end; indicates a
serious fault in the received signal at the far-end equipment.
Instructions:
1. Check for alarms at the far-end equipment. See instructions on them.
2. Check the condition of the cables and connectors, and the correct
polarities of the wire pairs at both ends.
3. Check that the pseudowire and pseudowire tunnel settings are correct
at both ends.
4. Check the transmission path of the pseudowire tunnel from the alarming
interface to the far end.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 464/486
464 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8281 FAULT IN OPTICAL INTERFACE (SFP)
222 8281 FAULT IN OPTICAL INTERFACE (SFP)
Meaning
A fault has been detected on the ethernet SFP interface. The insertedSFP module type is not supported, the inserted SFP module type could
not be identified, or there is a SFP module signals fault in the
transmitter.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies the physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 the number of the Q1 service channel in the BSC. The number can
be 0...27. If the equipment is supervised by the BTS, the channel
number is not relevant
6 the name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
7 the number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 465/486
DN998797 465
Transmission Equipment Alarms (8000-8999) 8281 FAULT IN OPTICAL INTERFACE (SFP)
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check the Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, open a remote session to thetransmission equipment and display the fault information.
For more detailed information on the fault code and corrective actions,
see the equipment's operating manual.
Flexi EDGE Flexi Multiradio:
Description: A fault is detected at the Ethernet SFP interface.
Instructions:
1. Check that the SFP module is correctly installed.
2. Check that the SFP module is of supported type (Ethernet 1000 Base-SX
or 1000 Base-LX).
3. Check that the electrical contacts of the SFP module are clean from
dust, dirt or water.
4. Replace the SFP module.
5. Replace FIxx.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 466/486
466 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8282 PSEUDOWIRE TUNNEL DOWN
223 8282 PSEUDOWIRE TUNNEL DOWN
Meaning
Pseudowire tunnel is not functional. No pseudowire packets have arrivedfor the configured VLAN and pseudowire local/peer IP address pair for
one second.
Possible causes are that there are no pseudowires configured on the
peer IP, the local or peer IP/gateway configurations are incorrect,
the peer subnet mask is incorrect, the far-end ARP resolution for the
local IP address has failed, the VLAN configuration is incorrect, or
there is no physical connection.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies the physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 the number of the Q1 service channel in the BSC. The number can
be 0...27. If the equipment is supervised by the BTS, the channel
number is not relevant
6 the name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
7 the number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
For more information, see the alarm's instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 467/486
DN998797 467
Transmission Equipment Alarms (8000-8999) 8282 PSEUDOWIRE TUNNEL DOWN
Id:0900d80580804c95
Confidential
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check the Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To find out the reason for the fault, open a remote session to the
transmission equipment and display the fault information.
For more detailed information on the fault code and corrective actions,
see the equipment's operating manual.
Flexi EDGE Flexi Multiradio:
Fault reason: Transmission is commissioned to be in Pseudowire (PWE)
mode without a licence.
Instructions:
1. Install and activate the 'Flexi EDGE Abis over IP/
Ethernet' licence at the BSC.
2. Recommission the site to use TDM mode.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically when
the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 468/486
468 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8283 LICENCE FOR IP SECURITY IS NOT AVAIL- ABLE
224 8283 LICENCE FOR IP SECURITY IS NOT
AVAILABLE
Meaning
The feature cannot be activated without a licence.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical
unit of the transmission equipment, for example a
plug-in unit or a daughter board. The number can be
0...254
4 the supervision block number specifies the faulty
part of the functional entity, for example a certain
line interface or component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 469/486
DN998797 469
Transmission Equipment Alarms (8000-8999) 8283 LICENCE FOR IP SECURITY IS NOT AVAIL- ABLE
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically
when the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 470/486
470 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8284 TRAFFIC SHAPING MISCONFIGURATION
225 8284 TRAFFIC SHAPING MISCONFIGURA-
TION
Meaning
Traffic shaping misconfigured. BTS-internal traffic shaping disabled but
Abis traffic shaping is enabled or CIR value of Abis traffic shaping is
smaller than CIR value of the BTS-internal uplink traffic shaping.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical
unit of the transmission equipment, for example a
plug-in unit or a daughter board. The number can be
0...254
4 the supervision block number specifies the faulty
part of the functional entity, for example a certain
line interface or component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 471/486
DN998797 471
Transmission Equipment Alarms (8000-8999) 8284 TRAFFIC SHAPING MISCONFIGURATION
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
The fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically
when the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 472/486
472 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8285 LICENCE FOR TIMING OVER PACKET IS NOT AVAILABLE
226 8285 LICENCE FOR TIMING OVER PACKET
IS NOT AVAILABLE
Meaning
The feature cannot be activated without a licence.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical
unit of the transmission equipment, for example a
plug-in unit or a daughter board. The number can be
0...254
4 the supervision block number specifies the faulty
part of the functional entity, for example a
certain line interface or component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 473/486
DN998797 473
Transmission Equipment Alarms (8000-8999) 8285 LICENCE FOR TIMING OVER PACKET IS NOT AVAILABLE
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically
when the fault has been corrected. Alarm is cancelled when the
license for ToP clock is made available or Alarm is cancelled when
ToP clock is removed from the priority list.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 474/486
474 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8286 LICENCE FOR SYNCHRONOUS ETHERNET ISNOT AVAILABLE
227 8286 LICENCE FOR SYNCHRONOUS
ETHERNET IS NOT AVAILABLE
Meaning
The feature cannot be activated without a licence.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical
unit of the transmission equipment, for example a
plug-in unit or a daughter board. The number can be
0...254
4 the supervision block number specifies the faulty
part of the functional entity, for example a certain
line interface or component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot FF = not defined
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 475/486
DN998797 475
Transmission Equipment Alarms (8000-8999) 8286 LICENCE FOR SYNCHRONOUS ETHERNET ISNOT AVAILABLE
Id:0900d80580804c95
Confidential
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically
when the fault has been corrected. Alarm is cancelled when the
license for SyncE clock is made available or Alarm is cancelled when
SyncE clock is removed from the priority list.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 476/486
476 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8287 CLOCK RECOVERY IN PROGRESS
228 8287 CLOCK RECOVERY IN PROGRESS
Meaning
BTS Timing over Packet Slave is running clock recovery algorithm andclock synchronisation is not yet complete
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical
unit of the transmission equipment, for example a
plug-in unit or a daughter board. The number can be
0...254
4 the supervision block number specifies the
faulty part of the functional entity, for example
a certain line interface or component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel
number is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object
field of the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object
field of the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised
by a BTS that supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised
by a BTS that supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 477/486
DN998797 477
Transmission Equipment Alarms (8000-8999) 8287 CLOCK RECOVERY IN PROGRESS
Id:0900d80580804c95
Confidential
a BTS that supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether
the BSC or the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands
Axx for alarm administration.
If the BTS supervises the equipment, use the MML commands
EOx for alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed
information on the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically
when the fault has been corrected. Alarm is cancelled after ToP
clock gets the lock or Alarm is cancelled when 30 minute timer
expires. Alarm Error in Connection with ToP Master is raised and ToP
Clock is marked as Not OK.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 478/486
478 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8288 FAULT IN CONNECTION TO CLOCK MASTER
229 8288 FAULT IN CONNECTION TO CLOCK
MASTER
Meaning
Timing over Packet master is not reachable or unable to
provide required synchronisation messages
Notes: This alarm is masked if Loss of Synchronisation or Frequency error alarm is
raised.
Rationale is that if BTS switches to internal clock, there will be already these
alarms and user can determine if ToP is root cause by checking related status
display.
The alarm is raised when:1. The difference between expected sync message rate and
actual sync message rate is less than 50% within 10 seconds.
2. If the announce grant from the master is ignored for the first time after a
timeout period of 2 seconds.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical
unit of the transmission equipment, for example a plug-in unit or a daughter board. The number can
be 0...254
4 the supervision block number specifies the faulty
part of the functional entity, for example a certain
line interface or component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 479/486
DN998797 479
Transmission Equipment Alarms (8000-8999) 8288 FAULT IN CONNECTION TO CLOCK MASTER
Id:0900d80580804c95
Confidential
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether
the BSC or the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands
Axx for alarm administration.
If the BTS supervises the equipment, use the MML commands
EOx for alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed
information on the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically
when the fault has been corrected. Alarm is cancelled when ToP Clock
gets the lock or ToP Clock is removed from priority list.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 480/486
480 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8289 SSM HAS LOST TRACEABILITY TO PRCCLOCK SOURCE
230 8289 SSM HAS LOST TRACEABILITY TO PRC
CLOCK SOURCE
Meaning
Invalid clock quality level received
Notes: This alarm is masked if Loss of Synchronisation or Frequency error alarm is
raised.
Rationale is that if BTS switches to internal clock, there will be already these
alarms and user can determine if SSM is root cause by checking related status
display.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit of the
transmission equipment, for example a plug-in unit or a
daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part of the
functional entity, for example a certain line interface or
component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that supports coordinate settings
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 481/486
DN998797 481
Transmission Equipment Alarms (8000-8999) 8289 SSM HAS LOST TRACEABILITY TO PRCCLOCK SOURCE
Id:0900d80580804c95
Confidential
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the BSC or
the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands Axx for
alarm administration.
If the BTS supervises the equipment, use the MML commands EOx for
alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed information on
the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm automatically
when the fault has been corrected.
Alarm is cancelled if SSM Operation is disabled or Alarm is
cancelled if SyncE Clock is deleted from Priority list or Alarm is
cancelled if SSM with QL PRC is received at the active SyncE port.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 482/486
482 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8290 LICENCE FOR PACKET TRS E1/T1 IS NOT AVAILABLE
231 8290 LICENCE FOR PACKET TRS E1/T1 IS
NOT AVAILABLE
Meaning
The feature cannot be activated without a licence.
This alarm affects the provided services.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit
of the Transmission equipment, for example a plug-in
unit or a daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part
of the Functional entity, for example a certain line
Interface or component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 483/486
DN998797 483
Transmission Equipment Alarms (8000-8999) 8290 LICENCE FOR PACKET TRS E1/T1 IS NOT AVAILABLE
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the
BSC or the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands
Axx for alarm administration.
If the BTS supervises the equipment, use the MML commands
EOx for alarm administration.
To clarify the reason for the fault, take a remote session to
transmission equipment and display fault information.
See the equipment operating manual for more detailed
information on the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm
automatically when the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 484/486
484 DN998797
Transmission Equipment Alarms (8000-8999)
Id:0900d80580804c95
Confidential
8291 PMTU BTS TO BSC LESS THAN CONFIGRUEDMTU
232 8291 PMTU BTS TO BSC LESS THAN CONFI-
GRUED MTU
Meaning
Path MTU (PMTU) to BSC has been determined by BTS to be less than the
configured MTU value.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit
of the transmission equipment, for example a plug-in
unit or a daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part
of the functional entity, for example a certain line
interface or component
5 number of the Q1 service channel in the BSC, 0...27.
If equipment is supervised by the BTS, the channel number
is not relevant
6 name of the piece of transmission equipment.
Not included if the name is in the alarm object field of
the alarm printout.
See alarm instructions
7 number of the piece of transmission equipment.
Not included if the index is in the alarm object field of
the alarm printout.
See alarm instructions
8 rack (cabinet) number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
9 shelf number
FF = not defined
Included only if the equipment is supervised by a BTS that
supports coordinate settings
10 slot
FF = not defined
Included only if the equipment is supervised by a BTS that
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 485/486
DN998797 485
Transmission Equipment Alarms (8000-8999) 8291 PMTU BTS TO BSC LESS THAN CONFIGRUEDMTU
Id:0900d80580804c95
Confidential
supports coordinate settings
Instructions
Check Supplementary information field 1 to see whether the
BSC or the BTS supervises the equipment.
If the BSC supervises the equipment, use the MML commands
Axx for alarm administration.
If the BTS supervises the equipment, use the MML commands
EOx for alarm administration.
To clarify the reason for the fault, take a remote session
to transmission equipment and display fault information.
See the equipment operating manual for more detailed
information on the fault code and corrective actions.
Cancelling
Do not cancel the alarm. The system cancels the alarm
automatically when the fault has been corrected.
7/25/2019 2G 8000 - 8999 Transmission Alarms
http://slidepdf.com/reader/full/2g-8000-8999-transmission-alarms 486/486
Transmission Equipment Alarms (8000-8999)8292 PMTU BTS TO SECURITY GATEWAY LESSTHAN CONFIGURED MTU
233 8292 PMTU BTS TO SECURITY GATEWAY
LESS THAN CONFIGURED MTU
Meaning
Path MTU (PMTU) to Security Gateway has been determined by BTS
to be less than the configured MTU value.
Supplementary information fields
1 01 BSC supervises the equipment
02 BTS supervises the equipment
2 Q1 address of the piece of transmission equipment
3 the functional entity number specifies a physical unit
of the transmission equipment, for example a plug-in unit
or a daughter board. The number can be 0...254
4 the supervision block number specifies the faulty part
of the functional entity, for example a certain line
interface or component
5 number of the Q1 service channel in the BSC, 0...27.