Page 1: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

Hurricane Ready™

Hurricane Ready™

Residential Garage Door Wind Load Overview

Raynor StyleView™ Eden Coast by Raynor®

Aspen™ AP138

RockCreeke™

Masterpiece™ & ShowCase™

Aspen™ AP200LV

TradeMark™

Aspen™ AP200

BuildMark™

Page 2: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

Hurricane ReadyResidential Garage DoorsDetermine Your Requirements

Step 1:Determine the minimum wind speed (MPH) your door must meet or exceed from the map below, or go to www.atcouncil.org/windspeed. Determine if wind borne debris is applicable. See map below.

Wind Borne DebrisThe wind borne debris region is also known as those areas that require the large missile impact rated door and/or windows. In Florida, being farther south and closer to the shoreline, it is more likely a home or building will be in the wind borne debris region or HVHZ (High Velocity Hurricane Zone - Miami-Dade and Broward counties).

Miami-Dade and Broward Counties require all garage doors meet the large missile impact rating, regardless if the garage door has windows or not.

Insurance companies sometimes give discounts for garage doors and other exterior building products that exceed the local building code, including meeting wind borne debris requirements not mandated. This means that installing a new garage door with the large missile impact rating may reduce your insurance premiums. Please check with your insurance agent for details.

Step 2:Determine if your home is in an Exposure B, Exposure C or Exposure D region.

Exposure BUrban and suburban areas, wooded areas or other terrain with numerous closely spaced obstructions.

Exposure COpen terrain with scattered obstructions, including flat open ground and grasslands. All of Miami-Dade and Broward Counties is Exposure C, unless it meets Exposure D definition.

Exposure DWithin 600 ft. of the ocean front or other large body of water, measuring at least 5,000 ft. across. Contact building code official or DASMA Technical Data Sheet #155t for design pressures.

Step 3:Determine the structural type of your home: one story or two story.

Step 4:Using wind speed (MPH), exposure and structural type, find your required design pressure. See chart on opposite page.

2

Page 3: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

Design PressuresThe design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the design pressure for the garage door opening in which a door is to be installed. Design pressure has positive and negative values.

Garage Door Wind Load Guide - Values in PSF

Mean Roof

Height

Door Size

Based on the 2010 and 2014 Florida Building Code & ASCE7-10,Exposure B, 115 - 200 MPH Ultimate Design Wind Speed, MPH (V_ult)

Ultimate Wind Speed g 115 MPH 120 MPH 130 MPH 140 MPH 150 MPH 160 MPH 170 MPH 180 MPH 190 MPH 200 MPH

Less Than 30 Feet

Single9' x7'

12.5-14.2

13.7-15.5

16.1-18.2

18.5-20.9

21.3-24.1

24.3-27.5

27.6-31.2

30.6-34.6

34.2-38.6

38.0-43.0

Double16' x 7'

12.0-13.4

13.1-14.6

15.5-17.2

17.7-19.7

20.4-22.7

23.3-26.0

26.4-29.4

29.3-32.6

32.7-36.5

36.4-40.6

Mean Roof

Height

Door Size

Based on the 2010 and 2014 Florida Building Code & ASCE7-10,Exposure C, 115-200 MPH Ultimate Design Wind Speed, MPH (V_ult)

Ultimate Wind Speed g 115 MPH 120 MPH 130 MPH 140 MPH 150 MPH 160 MPH 170* MPH 175**MPH 180 MPH 190 MPH 200 MPH

15 Feet Single Story

Single 9'x7'

15.2-17.2

16.6-18.8

19.6-22.2

22.4-25.3

25.9-29.2

29.5-33.4

33.5-37.8

35.3-39.9

37.1-42.0

41.5-46.9

46.2-52.2

Double 16' x 7'

14.6-16.2

15.9-17.7

18.8-20.9

21.5-23.9

24.8-27.6

28.3-31.5

32.1-35.7

33.8-37.7

35.5-39.6

39.8-44.3

44.2-49.3

25 Feet Double Story

Single 9'x7'

16.8-19.0

18.4-20.8

21.7-24.5

24.8-28.0

28.6-32.3

32.7-36.9

37.0-41.8

39.0-44.1

41.1-46.4

45.9-51.9

51.1-57.7

Double 16'x7'

16.1-18.0

17.6-19.6

20.8-23.1

23.7-26.5

27.4-30.5

31.3-34.9

35.5-39.5

37.4-41.7

39.3-43.8

44.0-49.0

48.9-54.5

*Broward County is 170 MPH, Exposure C for most residential buildings.**Miami-Dade county is 175 MPH, Exposure C for most residential buildings.The design pressures listed are the minimum required. Recommended wind load levels meet or exceed the required design pressures.MPH=miles per hour PSF= pounds per square foot

Mean Roof

Height

Door Size

Based on the 2010 and 2014 Florida Building Code & ASCE7-10,Exposure D, 115-200 MPH Ultimate Design Wind Speed, MPH (V_ult)

Ultimate Wind Speed g 115 MPH 120 MPH 130 MPH 140 MPH 150 MPH 160 MPH 170 MPH 175 MPH 180 MPH 190 MPH 200 MPH

15 Feet Single Story

Single 9'x7'

18.4-20.8

20.1-22.8

23.8-26.8

27.2-30.7

31.3-35.4

35.8-40.5

40.6-45.9

42.7-48.3

45.0-50.8

50.3-56.9

55.9-63.2

Double 16' x 7'

17.7-19.7

19.3-21.5

22.7-25.4

26.0-29.0

30.0-33.4

34.3-38.2

38.8-43.3

40.9-45.6

43.1-48.0

48.2-53.7

53.6-59.7

25 Feet Double Story

Single 9'x7'

20.1-22.7

21.9-24.7

25.8-29.2

29.5-33.4

34.1-38.5

38.9-44.0

44.1-49.9

46.5-52.5

48.9-55.3

54.7-61.8

60.8-68.7

Double 16'x7'

19.2-21.4

21.0-23.4

24.7-27.6

28.3-31.5

32.6-36.4

37.3-41.6

42.2-47.1

44.5-49.6

46.8-52.2

52.4-58.4

58.2-64.9

3

Page 4: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

4

STYLEVIEW WIDE - JULY 2020 UPDATES2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 200+9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

9’ WideIW: P-3319 (41.0/-46.3)

with impact glass

10’ Wide

F: P-2412 (34.0/-38.5) with DSB glass

T: P-2816 (34.0/-38.5) with DSB glass

12’ Wide

14’ WideF: P-2411 (14.2/-15.8)

With DSB glassF: P-2410 (25.5/-28.5)

with DSB glass

F: P-2409 (43.0/-48.0) with DSB glass

T: P-2809 (43.0/-48.0) with DSB glass

IW: P-3327 (43.0/-48.0) with impact glass

IR: P-2909 (43.0/-48.0) with impact glass

16’ Wide

F: P-2420 (27.5/-34.7) with DSB glass

T: P-2817 (27.5/-34.7) with DSB glass

18’ Wide

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Raynor StyleView™

An inspiration in both form and function, Raynor StyleView offers architectural flexibility, maximum visibility and extreme durability in maintenance-free aluminum doors. The Custom Profile, Wide Profile and Narrow Profile models feature a series of unprecedented designs, architectural glass options and 188 ArmorBrite™ powder coat or 7 anodized color finishes to showcase a home's unique flair. From modern styles to classic facades, Raynor StyleView is the choice for achieving a contemporary look or accentuating the design of any residence.

ColorsStandard Anodized Base Colors

Clear

Champagne

Light Bronze

Medium Bronze

Dark Bronze

Extra Dark Bronze

Black

Optional

Choose from over 188 Raynor ArmorBrite™ powder coat colors.The swatches shown on monitors and printed materials may vary from the actual color. For a

true representation of the color, visit your local Raynor Dealer.

"For As Long As You Own Your Home," against defects in material and workmanship.5-year finish warranty

Door Sections*

Hardware: 6 yearsSprings: 3 yearsEnduraCote: "For As Long As You Own Your Home"

Hardware/Springs*

*See www.raynor.com/products for complete Limited Warranty details.

Page 5: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

5

STYLEVIEW WIDE - JULY 2020 UPDATES2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 200+9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

9’ WideIW: P-3319 (41.0/-46.3)

with impact glass

10’ Wide

F: P-2412 (34.0/-38.5) with DSB glass

T: P-2816 (34.0/-38.5) with DSB glass

12’ Wide

14’ WideF: P-2411 (14.2/-15.8)

With DSB glassF: P-2410 (25.5/-28.5)

with DSB glass

F: P-2409 (43.0/-48.0) with DSB glass

T: P-2809 (43.0/-48.0) with DSB glass

IW: P-3327 (43.0/-48.0) with impact glass

IR: P-2909 (43.0/-48.0) with impact glass

16’ Wide

F: P-2420 (27.5/-34.7) with DSB glass

T: P-2817 (27.5/-34.7) with DSB glass

18’ Wide

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Panel OptionsCustom Carriage HouseSwing-Up

Swing-Out

No batten 1 batten 2 batten 3 batten

No batten 1 batten 2 batten

Accordion

1 batten 1 batten

Bi-Fold

No batten no batten 1 batten

1 batten 2 batten 3 batten

Custom Mixed Panel

MillCreek MillCreek Summitreef Summitreef with panels with panels

Ridgelake Bridgeport Shoreland

Ridgelake Bridgeport Shorelandwith panels with panels with panels

Edgewater Baypoint Highcrest

Edgewater Baypoint Highcrestwith panels with panels with panels

Springfield Brookview Riverside

Springfield Brookview Riversidewith panels with panels with panels

Window OptionsCustom Carriage House1 Pane

2 Pane

2 over 2 Pane

2 over 2 Pane

3 Pane

3 over 3 Pane

4 Pane

4 over 4 Pane

Prairie (Simulated Only)

Wide ProfileSingle Car

Single car, 4’0” to 9’2”, 2 panel design

Single car, 9’3” to 12’2”, 3 panel design

Double Car

Double car 12’3” to 20’0”, 4&5 panel designs

Page 6: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

6

EDEN COAST BY RAYNOR - JULY 2020 UPDATES2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 200+9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

8’ WIDE

F: P-2381 (34.5/-39.0) No Windows

F: P-2382 (37.1/-41.2) No Windows

9’ WIDE

F: P-2381 (30.7/-34.7) No Windows

F: P-2382 (33.0/-36.6) No Windows

10’ WIDE

F: P-2381 (27.6/-31.2) No Windows

F: P-2382 (29.7/-33.0) No Windows

12’ WIDEF: P-2382

(24.4/-27.2) No Windows

14’ WIDEF: P-2382

(21.0/-23.3) No Windows

16’ WIDEF: P-2382

(18.3/-20.4) No Windows

18’ WIDEF: P-2382

(18.3/-20.4) No Windows

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Eden Coast by Raynor®

Eden Coast by Raynor doors are handcrafted by overlaying steel sections with environmentally-friendly composite material, providing a high-end wood look, without any of the maintenance. No matter the design, all of our overlays are impervious to moisture, mold and mildew because they are built with environmentally friendly composite materials that provide the beauty of naturally strained wood. Underneath our overlays is a sturdy and durable NeuFoam™ insulated steel door base, guarding your garage against hot and cold temperatures.

"For As Long As You Own Your Home," against rust.Certain restrictions apply to corrosive airborne substances.

Door Sections*

18.3

R-value

Hardware: 6 yearsSprings: 3 years

Hardware/Springs*

*See www.raynor.com/products for complete Limited Warranty details.

Page 7: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

7

EDEN COAST BY RAYNOR - JULY 2020 UPDATES2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 200+9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

8’ WIDE

F: P-2381 (34.5/-39.0) No Windows

F: P-2382 (37.1/-41.2) No Windows

9’ WIDE

F: P-2381 (30.7/-34.7) No Windows

F: P-2382 (33.0/-36.6) No Windows

10’ WIDE

F: P-2381 (27.6/-31.2) No Windows

F: P-2382 (29.7/-33.0) No Windows

12’ WIDEF: P-2382

(24.4/-27.2) No Windows

14’ WIDEF: P-2382

(21.0/-23.3) No Windows

16’ WIDEF: P-2382

(18.3/-20.4) No Windows

18’ WIDEF: P-2382

(18.3/-20.4) No Windows

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

ColorsStain Finish Options

Light Cherry

Red Walnut

Dark Cherry

Walnut

Red Mahogany

Mahogany

Dark Cedar

Driftwood

Oak

Natural

Panel OptionsDoor Styles: One and Two Car options AvailableMaximum Door Sizes: 10'0" x 18'2"

Anderson Asheville Birmingham Bridgemill Cambridge Charleston

Hampton Leatherwood Louisville Magnolia Magnolia-Arch Providence

Saratoga St. Augustine Summerhaven Williamsburg Custom

Stain colors shown are for reference only and are not indicative of what the final production color will be. As with all hand stained finishes, slight

variations in color and consistency can occur. Backing and overlays are fin-ished in the same color. Ask your authorized Raynor dealer to see samples

of actual stain options available.

Edges

Round Over Molding (Available at an additional cost.)

RoutedSquare

Backing

FlushV-Groove

For non impact window options please see page 25.

Page 8: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

8

RockCreeke™

Designed to provide unsurpassed character in a maintenance-free design, Raynor RockCreeke overlay doors feature an environmentally stable trim board material. With a long-lasting vinyl capstock, this trim board material has an attractive appearance that holds up over time. Best of all, the material technology can utilize "reclaimed" wood fiber and vinyl from post production processes, helping to save natural resources. And, with an R-value of 13, RockCreeke doors have durable 1⅜" polyurethane insulated base door sections for thermal efficiency and maximum structural integrity.

"For As Long As You Own Your Home," against rust.Certain restrictions apply to corrosive airborne substances.

Door Sections*

12.0

R-value

Hardware: 6 yearsSprings: 3 yearsEnduraCote: "For As Long As You Own Your Home"

Hardware/Springs*

*See www.raynor.com/products for complete Limited Warranty details.

ROCKCREEKE - JULY 2020 UPDATES

2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 200+

9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

8’ WIDE

F: P-2346 (34.5/-39.0) Ranch glass

T: P-2807 (34.5/-39.0) Ranch glass

F: P-2347 (37.1/-41.2) Ranch glass

IR: P-3340 (52.4/-57.0)

9’ WIDE

F: P-2346 (30.7/-34.7) Ranch glass

T: P-2807 (30.7/-34.7) Ranch glass

F: P-2347 (33.0/-36.6) Ranch glass

IR: P-3340 (52.4/-57.0)

10’ WIDE

F: P-2346 (27.6/-31.2) Ranch glass

T: P-2807 (27.6/-31.2) Ranch glass

F: P-2347 (29.7/-33.0) Ranch glass

IR: P-3340 (52.4/-57.0)T: P-2906 (52.4/-57.0)

12’ WIDEF: P-2347 (24.4/-27.2)

Ranch glassIR: P-3340 (32.7/-39.4)

14’ WIDEF: P-2347 (21.0/-23.3)

Ranch glassIR: P-3340 (32.7/-39.4)

16’ WIDE

F: P-2347 (18.3/-20.4) Ranch glass

T: P-2808 (18.3/-20.4) Ranch glass

IR: P-3340 (32.7/-39.4)T: P-2906 (32.7/-39.4)

18’ WIDEIR: P-3340 (25.9/-31.1)T: P-2906 (25.9/-31.1)

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Page 9: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

9

Panel OptionsDoor Styles: Simulated Swing-Out, Bi-fold, and Accordion (12' only)Sizes: Height: up to 10' in 6" increments Widths: 8'0", 9'0", 10'0", 12'0", 16'0", 18'0"(Accordion style doors only available in 12' widths)

Swing-Out Single-Car and Double-Car Panel Configurations

1 car 1 car with windows

1 car withV bucks

1 car with V bucks & windows

1 car withA bucks

1 car with A bucks & windows

1 car withX bucks

1 car with X bucks & windows

Accordion Panel Configurations (Only Available in 12' widths)

12' 12' bi-fold 12' with A bucks

12' with V bucks 12' with X bucks

ColorsStandard Base Colors

White

Almond

Black

Bronze

Brown

Desert Tan

Sandstone

Charcoal

Standard Board Color

White

Optional Board Color

Almond

Black

Bronze

Brown

Desert Tan

Sandstone

Charcoal

The swatches shown on monitors and printed materials may vary from the actual color. For a true representation

of the color, visit your local Raynor Dealer.

Bi-Fold

1 car 1 car with windows

ROCKCREEKE - JULY 2020 UPDATES

2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 200+

9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

8’ WIDE

F: P-2346 (34.5/-39.0) Ranch glass

T: P-2807 (34.5/-39.0) Ranch glass

F: P-2347 (37.1/-41.2) Ranch glass

IR: P-3340 (52.4/-57.0)

9’ WIDE

F: P-2346 (30.7/-34.7) Ranch glass

T: P-2807 (30.7/-34.7) Ranch glass

F: P-2347 (33.0/-36.6) Ranch glass

IR: P-3340 (52.4/-57.0)

10’ WIDE

F: P-2346 (27.6/-31.2) Ranch glass

T: P-2807 (27.6/-31.2) Ranch glass

F: P-2347 (29.7/-33.0) Ranch glass

IR: P-3340 (52.4/-57.0)T: P-2906 (52.4/-57.0)

12’ WIDEF: P-2347 (24.4/-27.2)

Ranch glassIR: P-3340 (32.7/-39.4)

14’ WIDEF: P-2347 (21.0/-23.3)

Ranch glassIR: P-3340 (32.7/-39.4)

16’ WIDE

F: P-2347 (18.3/-20.4) Ranch glass

T: P-2808 (18.3/-20.4) Ranch glass

IR: P-3340 (32.7/-39.4)T: P-2906 (32.7/-39.4)

18’ WIDEIR: P-3340 (25.9/-31.1)T: P-2906 (25.9/-31.1)

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Page 10: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

10

AP200LV - JULY 2020 UPDATES2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 200+9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

8’ Wide

9’ WideF: P-2371

(18.5/-20.9) Ranch glass

F: P-2372 (32.7/-36.5) Ranch glass

F: P-2373 (43.3/-49.0) Ranch glass

10’ Wide

12’ WideF: P-2371

(11.4/-12.9) Ranch glass

F: P-2372 (21.3/-27.5) Ranch glass

F: P-2373 (27.6/-31.2) Ranch glass

14’ Wide

16’ WideF: P-2372 (13.1/-15.5)

Ranch glass

F: P-2373 (15.5/-19.7) Ranch glass

F: P-2374 (32.7/-36.5) Ranch glass

18’ WideF: P-2373 (12.0/-13.9)

Ranch glassF: P-2374 (23.3/-29.4)

Ranch glass

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Aspen™ AP200LVAP200LV LuxeVue door by Raynor® combines all of the aesthetic design options of our Aspen™ AP200 line with a dramatically larger top window section to create a beautiful door, with stunning curb appeal.

"For As Long As You Own Your Home," against rust.Certain restrictions apply to corrosive airborne substances.

Door Sections*

18.0

R-value

Hardware: 6 yearsSprings: 3 yearsEnduraCote: "For As Long As You Own Your Home"

Hardware/Springs*

*See www.raynor.com/products for complete Limited Warranty details.

LuxeVue™ Standard

Page 11: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

11

AP200LV - JULY 2020 UPDATES2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 200+9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

8’ Wide

9’ WideF: P-2371

(18.5/-20.9) Ranch glass

F: P-2372 (32.7/-36.5) Ranch glass

F: P-2373 (43.3/-49.0) Ranch glass

10’ Wide

12’ WideF: P-2371

(11.4/-12.9) Ranch glass

F: P-2372 (21.3/-27.5) Ranch glass

F: P-2373 (27.6/-31.2) Ranch glass

14’ Wide

16’ WideF: P-2372 (13.1/-15.5)

Ranch glass

F: P-2373 (15.5/-19.7) Ranch glass

F: P-2374 (32.7/-36.5) Ranch glass

18’ WideF: P-2373 (12.0/-13.9)

Ranch glassF: P-2374 (23.3/-29.4)

Ranch glass

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

For non impact window options please see page 25.

Panel Options

Raised Colonial Recessed Colonial Grooved

Raised Ranch Recessed Ranch Grooved

Flush Plank

ColorsSolid Color Options

White

Almond

Desert Tan

Sandstone

Bronze

Brown

Charcoal

Black

Distinct Finish Woodtone Options

Painted Woodtone Options

Optional Post Paint FinishRaynor’s ColorWave™ features 1,500 Sherwin-Williams® next generation post paint system for your garage door.

DriftwoodAuburn Mocha

Walnut

The swatches shown on monitors and printed materials may vary from the actual color. For a true representation

of the color, visit your local Raynor Dealer.

Page 12: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

12

AP200 - JULY 2020 UPDATES

2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 210 210+

9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

8’ Wide F: P-2339 (20.8/-23.5) Ranch glass

F: P-2340 (48.6/-55.0) Ranch glass

IW: P-3344 (60.0/-65.0) Ranch glass

F: P-2341 (63.1/-70.4) Ranch glass

F: P-2342 (82.5/-90.0) No glass

IR: P-3342 (73.0/-80.0) No Windows

9’ Wide F: P-2339 (18.5/-20.9) Ranch glass

F: P-2340 (43.2/-48.9) Ranch glass

T: P-2800 (43.2/-48.9) Ranch glass

IW: P-3343 (56.1/-62.6) Colonial windows

F: P-2341 (56.1/-62.6) Ranch glass

T: P-2801 (56.1/-62.6) Ranch glass

IW: P-3341 (62.0/-69.0) Colonial windows

F: P-2342 (73.3/-80.0) No glass

IW: P-3344 (60.0/-65.0) Ranch glass

T: P-2900 (60.0/-65.0) Ranch glass

IR: P-3342 (73.0/-80.0) No Windows

IW: P-3345 (60.0/-65.0) Ranch glass

10’ Wide F: P-2339 (15.0/-16.9) Ranch glass

F: P-2340 (35.0/-39.6) Ranch glass

IW: P-3344 (42.8/-47.6) Ranch windows

F: P-2341 (45.4/-50.7) Ranch glass

F: P-2446 (50.0/-55.0) Colonial. / Ranch windowsIW: P-3346 (50.0/-55.0)

Colonial. / Ranch windowsT: P-2901 (50.0/-55.0)

Colonial. / Ranch windows

IR: P-3342 (56.5/-65.5) No Windows

F: P-2342 (72.0/-83.2) No glass

12’ Wide F: P-2340 (24.3/-27.5) Ranch glass

IW: P-3343 (31.6/-35.2) Colonial windows

F: P-2341 (31.6/-35.2) Ranch glass

IW: P-3344 (42.8/-47.6) Ranch windows

IR: P-3342 (56.5/-65.5) No Windows

F: P-2342 (60.0/-69.3) No glass

14’ Wide F: P-2340 (17.9/-20.2) Ranch glass

F: P-2341 (23.2/-25.9) Ranch glass

IW: P-3344 (32.5/-35.9) Ranch Windows

F: P-2342 (51.4/-59.4) No glass

IR: P-3342 (45.0/-52.0) No Windows

16’ Wide F: P-2340 (13.7/-15.5) Ranch glass

F: P-2341 (17.8/-19.8) Ranch glass

F: P-2446 (20.4/-22.7) Colonial / Ranch windows

P-3346 (20.4/-22.7) Col. / Ran. windows

IW: P-3344 (32.5/-35.9) Ranch windows

T: P-2900 (32.5/-35.9) Ranch glass

IW: P-3341 (36.5/-40.6) Colonial windows

F: P-2342 (45.0/-52.0) No glass

T: P-2802 (45.0/-52.0) No glass

IR: P-3342 (45.0/-52.0) No Windows

18’ Wide F: P-2340 (10.8/-12.2)Ranch glass

F: P-2341 (14.0/-15.7) Ranch glass

IW: P-3344 (24.5/-26.9) Ranch windows

F: P-2342 (37.1/-40.7) No glass

IR: P-3342 (33.4/-36.7) No Windows

T: P-2902 (33.4/-36.7) No Windows

20’ Wide F: P-2341 (11.4/-12.7)Ranch glass

IW: P-3341 (23.3/-26.0) Colonial windows

IW: P-3344 (24.5/-26.9) Ranch windows

F: P-2342 (33.4/-36.7) No glass

T: P-2802 (33.4/-36.7) No glass

IR: P-3342 (33.4/-36.7) No Windows

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Aspen™ AP200The Aspen™ model AP200 is a 2" thick, thermally efficient door, featuring Neufoam™ polyurethane insulation that fills 100% of the section's interior. Combine this with all the decorative options available, and you have a best-in-class door that just can't be beat.

"For As Long As You Own Your Home," against rust.Certain restrictions apply to corrosive airborne substances.

Door Sections*

18.0

R-value

Hardware: 6 yearsSprings: 3 yearsEnduraCote: "For As Long As You Own Your Home"

Hardware/Springs*

*See www.raynor.com/products for complete Limited Warranty details.

Page 13: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

13

AP200 - JULY 2020 UPDATES

2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 210 210+

9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

8’ Wide F: P-2339 (20.8/-23.5) Ranch glass

F: P-2340 (48.6/-55.0) Ranch glass

IW: P-3344 (60.0/-65.0) Ranch glass

F: P-2341 (63.1/-70.4) Ranch glass

F: P-2342 (82.5/-90.0) No glass

IR: P-3342 (73.0/-80.0) No Windows

9’ Wide F: P-2339 (18.5/-20.9) Ranch glass

F: P-2340 (43.2/-48.9) Ranch glass

T: P-2800 (43.2/-48.9) Ranch glass

IW: P-3343 (56.1/-62.6) Colonial windows

F: P-2341 (56.1/-62.6) Ranch glass

T: P-2801 (56.1/-62.6) Ranch glass

IW: P-3341 (62.0/-69.0) Colonial windows

F: P-2342 (73.3/-80.0) No glass

IW: P-3344 (60.0/-65.0) Ranch glass

T: P-2900 (60.0/-65.0) Ranch glass

IR: P-3342 (73.0/-80.0) No Windows

IW: P-3345 (60.0/-65.0) Ranch glass

10’ Wide F: P-2339 (15.0/-16.9) Ranch glass

F: P-2340 (35.0/-39.6) Ranch glass

IW: P-3344 (42.8/-47.6) Ranch windows

F: P-2341 (45.4/-50.7) Ranch glass

F: P-2446 (50.0/-55.0) Colonial. / Ranch windowsIW: P-3346 (50.0/-55.0)

Colonial. / Ranch windowsT: P-2901 (50.0/-55.0)

Colonial. / Ranch windows

IR: P-3342 (56.5/-65.5) No Windows

F: P-2342 (72.0/-83.2) No glass

12’ Wide F: P-2340 (24.3/-27.5) Ranch glass

IW: P-3343 (31.6/-35.2) Colonial windows

F: P-2341 (31.6/-35.2) Ranch glass

IW: P-3344 (42.8/-47.6) Ranch windows

IR: P-3342 (56.5/-65.5) No Windows

F: P-2342 (60.0/-69.3) No glass

14’ Wide F: P-2340 (17.9/-20.2) Ranch glass

F: P-2341 (23.2/-25.9) Ranch glass

IW: P-3344 (32.5/-35.9) Ranch Windows

F: P-2342 (51.4/-59.4) No glass

IR: P-3342 (45.0/-52.0) No Windows

16’ Wide F: P-2340 (13.7/-15.5) Ranch glass

F: P-2341 (17.8/-19.8) Ranch glass

F: P-2446 (20.4/-22.7) Colonial / Ranch windows

P-3346 (20.4/-22.7) Col. / Ran. windows

IW: P-3344 (32.5/-35.9) Ranch windows

T: P-2900 (32.5/-35.9) Ranch glass

IW: P-3341 (36.5/-40.6) Colonial windows

F: P-2342 (45.0/-52.0) No glass

T: P-2802 (45.0/-52.0) No glass

IR: P-3342 (45.0/-52.0) No Windows

18’ Wide F: P-2340 (10.8/-12.2)Ranch glass

F: P-2341 (14.0/-15.7) Ranch glass

IW: P-3344 (24.5/-26.9) Ranch windows

F: P-2342 (37.1/-40.7) No glass

IR: P-3342 (33.4/-36.7) No Windows

T: P-2902 (33.4/-36.7) No Windows

20’ Wide F: P-2341 (11.4/-12.7)Ranch glass

IW: P-3341 (23.3/-26.0) Colonial windows

IW: P-3344 (24.5/-26.9) Ranch windows

F: P-2342 (33.4/-36.7) No glass

T: P-2802 (33.4/-36.7) No glass

IR: P-3342 (33.4/-36.7) No Windows

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Panel Options

Raised Colonial Raised Ranch Recessed Ranch Grooved

Recessed Colonial Grooved Mixed Raised Panel Flush

Plank (Beadline)For impact window options please see page 23.

For non impact window options please see page 24.

ColorsSolid Color Options

White

Almond

Desert Tan

Sandstone

Bronze

Brown

Charcoal

Black

Distinct Finish Woodtone Options

Painted Woodtone Options Optional Post Paint Finish

Raynor’s ColorWave™ features 1,500 Sherwin-Williams® next generation post paint system for your garage door.

The swatches shown on monitors and printed materials may vary from the actual color. For a true representation of the color, visit your local Raynor Dealer.

DriftwoodAuburn Mocha

Walnut

Page 14: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

14

AP138 - JULY 2020 UPDATES2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 100 110 115 120 130 140 150 160 170 180 190 200 210 210+9’ x 7’ EXP B 9.6/-10.9 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 9.2/-10.3 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

8’ Wide F: P-2339 (12.8/-14.0) Ranch glass

F: P-2340 (31.1/-35.1) Ranch glass

F: P-2341 (55.1/-61.2) Ranch glass

IW: P-3344 (55.0/-62.0) Ranch windows

F: P-2342 (74.5/-82.5) No glass

IR: P-3342 (66.3/-73.0) No windows

9’ Wide F: P-2339 (11.4/-12.4) Ranch glass

P-2339 (12.6/-14.2) Ranch glass (24”)

F: P-2340 (27.6/-31.2) Ranch glass

T: P-2800 (27.6/-31.2) Ranch glass

P-2340 (34.2/-38.6) Ranch glass (24”)

IW: P-3343 (49.0/-54.4) Colonial windows

F: P-2341 (49.0/-54.4) Ranch glass

T: P-2801 (49.0/-54.4) Ranch glass

IW: P-3341 (55.0/-62.0) Colonial windows

IW: P-3344 (55.0/-62.0) Ranch windows

T: P-2900 (55.0/-62.0) Ranch windows

F: P-2342 (66.3/-73.0) No windows

IR: P-3342 (66.3/-73.0) No windows

10’ Wide F: P-2340 (22.4/-25.3) Ranch glass

F: P-2341 (39.7/-44.1) Ranch glass

IW: P-3344 (39.1/-43.5) Ranch windows

IR: P-3342 (51.5/-60.6) No windows

F: P-2446 (50.0/-55.0) Colonial / Ranch windowsIW: P-3346 (50.0/-55.0)

Colonial / Ranch windowsT: P-2901 (50.0/-55.0)

Colonial / Ranch windows

F: P-2342 (59.2/-72.0) No windows

12’ Wide P-2340 (18.5/-20.9) Ranch glass (24”)

F: P-2340 (21.4/-23.7) Ranch glass

P-2341 (21.3/-27.5) Ranch glass (24”)

IW: P-3343 (49.0/-54.4) Colonial windows

F: P-2341 (27.6/-30.6) Ranch glass

IW: P-3344 (39.1/-43.5) Ranch windows

F: P-2342 (49.3/-60.0) No glass

IR: P-3342 (51.5/-60.6) No windows

14’ Wide F: P-2340 (15.7/-17.4) Ranch glass

F: P-2341 (20.3/-22.5) Ranch glass

IW: P-3344 (29.7/-33.1) Ranch windows

F: P-2342 (42.0/-51.4) No glass

F: P-3342 (37.0/-45.0) No windows

16’ Wide P-2340 (9.2/-10.3) Ranch glass (24”)

F: P-2340 (12.0/-13.4) Ranch glass

P-2341 (13.1/-17.2)

Ranch glass (24”)

F: P-2341 (15.5/-17.2) Ranch glass

F: P-2446 (20.4/-22.7) Colonial / Ranch

WindowsIW: P-3346 (20.4/-22.7)

Colonial / Ranch windows

Doors needed with non-impact

glass

IW: P-3341 (29.3/-32.6) Colonial windows

IW: P-3344 (29.7/-33.1) Ranch windows

T: P-2900 (29.7/-33.1) Ranch windows

F: P-2342 (37.0/-45.0) No glass

T: P-2802 (37.0/-45.0) No glass

IR: P-3342 (37.0/-45.0) No windows

18’ Wide F: P-2341 (12.3/-13.6) Ranch glass

IW: P-3344 (22.5/-24.7) Ranch windows

Doors needed with non-impact

glass

F: P-2342 (37.1/-40.7) No glass

IR: P-3342 (33.4/-36.7) No Windows

T: P-2902 (33.4/-36.7) No Windows

20’ Wide F: P-2341 (9.9/-11.0) Ranch glass

IW: P-3341 (20.1/-22.7) Colonial windows

IW: P-3344 (22.5/-24.7) Ranch windows

F: P-2342 (33.4/-36.7) No glass

T: P-2802 (33.4/-36.7) No glass

IR: P-3342 (33.4/-36.7) No Windows

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Aspen™ AP138The Aspen™ model AP138 is a 1⅜" thick, thermally efficient door, featuring Neufoam™ polyurethane insulation that fills 100% of the section's interior. Combine this with all the decorative options available, and you have a best-in-class door. The AP138 is ideal for moderate climates.

"For As Long As You Own Your Home," against rust.Certain restrictions apply to corrosive airborne substances.

Door Sections*

13.0

R-value

Hardware: 6 yearsSprings: 3 yearsEnduraCote: "For As Long As You Own Your Home"

Hardware/Springs*

*See www.raynor.com/products for complete Limited Warranty details.

Page 15: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

15

AP138 - JULY 2020 UPDATES2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 100 110 115 120 130 140 150 160 170 180 190 200 210 210+9’ x 7’ EXP B 9.6/-10.9 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 9.2/-10.3 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

8’ Wide F: P-2339 (12.8/-14.0) Ranch glass

F: P-2340 (31.1/-35.1) Ranch glass

F: P-2341 (55.1/-61.2) Ranch glass

IW: P-3344 (55.0/-62.0) Ranch windows

F: P-2342 (74.5/-82.5) No glass

IR: P-3342 (66.3/-73.0) No windows

9’ Wide F: P-2339 (11.4/-12.4) Ranch glass

P-2339 (12.6/-14.2) Ranch glass (24”)

F: P-2340 (27.6/-31.2) Ranch glass

T: P-2800 (27.6/-31.2) Ranch glass

P-2340 (34.2/-38.6) Ranch glass (24”)

IW: P-3343 (49.0/-54.4) Colonial windows

F: P-2341 (49.0/-54.4) Ranch glass

T: P-2801 (49.0/-54.4) Ranch glass

IW: P-3341 (55.0/-62.0) Colonial windows

IW: P-3344 (55.0/-62.0) Ranch windows

T: P-2900 (55.0/-62.0) Ranch windows

F: P-2342 (66.3/-73.0) No windows

IR: P-3342 (66.3/-73.0) No windows

10’ Wide F: P-2340 (22.4/-25.3) Ranch glass

F: P-2341 (39.7/-44.1) Ranch glass

IW: P-3344 (39.1/-43.5) Ranch windows

IR: P-3342 (51.5/-60.6) No windows

F: P-2446 (50.0/-55.0) Colonial / Ranch windowsIW: P-3346 (50.0/-55.0)

Colonial / Ranch windowsT: P-2901 (50.0/-55.0)

Colonial / Ranch windows

F: P-2342 (59.2/-72.0) No windows

12’ Wide P-2340 (18.5/-20.9) Ranch glass (24”)

F: P-2340 (21.4/-23.7) Ranch glass

P-2341 (21.3/-27.5) Ranch glass (24”)

IW: P-3343 (49.0/-54.4) Colonial windows

F: P-2341 (27.6/-30.6) Ranch glass

IW: P-3344 (39.1/-43.5) Ranch windows

F: P-2342 (49.3/-60.0) No glass

IR: P-3342 (51.5/-60.6) No windows

14’ Wide F: P-2340 (15.7/-17.4) Ranch glass

F: P-2341 (20.3/-22.5) Ranch glass

IW: P-3344 (29.7/-33.1) Ranch windows

F: P-2342 (42.0/-51.4) No glass

F: P-3342 (37.0/-45.0) No windows

16’ Wide P-2340 (9.2/-10.3) Ranch glass (24”)

F: P-2340 (12.0/-13.4) Ranch glass

P-2341 (13.1/-17.2)

Ranch glass (24”)

F: P-2341 (15.5/-17.2) Ranch glass

F: P-2446 (20.4/-22.7) Colonial / Ranch

WindowsIW: P-3346 (20.4/-22.7)

Colonial / Ranch windows

Doors needed with non-impact

glass

IW: P-3341 (29.3/-32.6) Colonial windows

IW: P-3344 (29.7/-33.1) Ranch windows

T: P-2900 (29.7/-33.1) Ranch windows

F: P-2342 (37.0/-45.0) No glass

T: P-2802 (37.0/-45.0) No glass

IR: P-3342 (37.0/-45.0) No windows

18’ Wide F: P-2341 (12.3/-13.6) Ranch glass

IW: P-3344 (22.5/-24.7) Ranch windows

Doors needed with non-impact

glass

F: P-2342 (37.1/-40.7) No glass

IR: P-3342 (33.4/-36.7) No Windows

T: P-2902 (33.4/-36.7) No Windows

20’ Wide F: P-2341 (9.9/-11.0) Ranch glass

IW: P-3341 (20.1/-22.7) Colonial windows

IW: P-3344 (22.5/-24.7) Ranch windows

F: P-2342 (33.4/-36.7) No glass

T: P-2802 (33.4/-36.7) No glass

IR: P-3342 (33.4/-36.7) No Windows

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Panel Options

Raised Colonial Raised Ranch Recessed Ranch Grooved

Recessed Colonial Grooved Mixed Raised Panel Flush

Plank (Beadline)For impact window options please see page 23.

For non impact window options please see page 24.

ColorsSolid Color Options

White

Almond

Desert Tan

Sandstone

Bronze

Brown

Charcoal

Black

Distinct Finish Woodtone Options

Painted Woodtone Options Optional Post Paint Finish

Raynor’s ColorWave™ features 1,500 Sherwin-Williams® next generation post paint system for your garage door.

The swatches shown on monitors and printed materials may vary from the actual color. For a true representation of the color, visit your local Raynor Dealer.

DriftwoodAuburn Mocha

Walnut

Page 16: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

16

Showcase/Masterpiece - July 2020 Updates

2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size

MPH 110 115 120 130 140 150 160 170 180 190 200 210 210+

9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

9’ Wide N: P-2312 (12.3/-13.7)

IW: P-3325 (41.6/-47.1) Colonial Glass

D: P-3305 (52.0/-58.0)P-3312 (65.0/-75.0)

N: P-1303 (37.3/-37.3) Colonial/Ranch Glass

10’ WideF: P-1339 (29.0/-32.5)

Ranch GlassD: P-3312 (56.4/-65.1)

12’ Wide D: P-3312 (56.4/-65.1)

16’ Wide N: P-2313 (12.3/-13.7)

F: P-2365 (18.0/-20.0) Ranch Glass

F: P-2365 (26.4/29.4)IR: P-3324 (29.7/-33.1)

D: P-3312 (45.0/-52.0)N: P-1309 (18.7/-18.7) Colonial/Ranch Glass

IW: P-3332 (29.7/-33.1) Colonial glass

18’ WideF: P-2418 (18/-20.0)

Ranch glassIW: P-3332 (23.5/-26.2)

Colonial glass

N: P-3309 (45.3/-51.2) D: P-3314 (43.5/-50.0)

P-3314 (43.5/-50.0)

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Masterpiece™ & ShowCase™

The flagship of the Raynor Traditions Series, Raynor Masterpiece steel garage doors feature 2” thick sections, a continuous thermal break between sections, and expanded polystyrene insulation bonded between two steel skins, for an outstanding 10.25 R-value. Masterpiece features the EnduraCote™ hardware system, while ShowCase uses galvanized hardware. Masterpiece and ShowCase doors are available in post, u-bar, and strut designs.

"For As Long As You Own Your Home," against rust.Certain restrictions apply to corrosive airborne substances.

Door Sections*

10.25

R-value

Masterpiece:"For As Long As You Own Your Home"ShowCase:Hardware: 6-yearsSpring: 3-years

Hardware/Springs*

*See www.raynor.com/products for complete Limited Warranty details.

Page 17: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

17

Showcase/Masterpiece - July 2020 Updates

2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size

MPH 110 115 120 130 140 150 160 170 180 190 200 210 210+

9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

9’ Wide N: P-2312 (12.3/-13.7)

IW: P-3325 (41.6/-47.1) Colonial Glass

D: P-3305 (52.0/-58.0)P-3312 (65.0/-75.0)

N: P-1303 (37.3/-37.3) Colonial/Ranch Glass

10’ WideF: P-1339 (29.0/-32.5)

Ranch GlassD: P-3312 (56.4/-65.1)

12’ Wide D: P-3312 (56.4/-65.1)

16’ Wide N: P-2313 (12.3/-13.7)

F: P-2365 (18.0/-20.0) Ranch Glass

F: P-2365 (26.4/29.4)IR: P-3324 (29.7/-33.1)

D: P-3312 (45.0/-52.0)N: P-1309 (18.7/-18.7) Colonial/Ranch Glass

IW: P-3332 (29.7/-33.1) Colonial glass

18’ WideF: P-2418 (18/-20.0)

Ranch glassIW: P-3332 (23.5/-26.2)

Colonial glass

N: P-3309 (45.3/-51.2) D: P-3314 (43.5/-50.0)

P-3314 (43.5/-50.0)

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Panel Options

Raised Colonial Raised Ranch Beadline

Carriage House (Grooved) Flush For impact window options please see page 23. For non impact window options please see page 25.

ColorsStandard

White

Almond

Bronze

Beige*

Brown*

*Features the Kynar® paint process, which provides

extended UV protection against fading.

Optional

Raynor’s ColorWave™ features 1,500 Sherwin-Williams® next generation post paint system for your garage door.

The swatches shown on monitors and printed materials may vary from the actual color. For a true representation

of the color, visit your local Raynor Dealer.

Page 18: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

18

TradeMark - JULY 2020 UPDATES

2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 210 210+

9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

9’ WideN: P-2392 (12.8/14.5) Colonial / Ranch glass

F: P-2300 (18.5/-20.9) Colonial / Ranch glass

F: P-2301 (24.8/-28.0) Colonial / Ranch glassT: P-2803 (24.8/-28.0) Colonial / Ranch glass

F: P-2301 (31.0/-35.1) Colonial glass (3) stilesT: P-2803 (24.8/-28.0) Colonial glass (3) stiles

IW: P-3348 (36.6/-41.1) Ranch glass

IR: P-3321 (41.6/-47.1)IW: P-3322 (41.6/-47.1)

Colonial glassT: P-2903 (41.6/-47.1)

Colonial glass

D: P-3307 (65.0/-75.0)T: P-2907 (65.0/-75.0)

10’ WideN: P-2324 (22.8/-25.8)

Colonial glassN: P-2325 (26.7/-30.2)

Colonial glassD: P-3307 (56.4/-65.1)

12’ WideD: P-3307 (56.4/-65.1)T: P-2907 (56.4/-65.1)

16’ Wide

N: P-2326 (12.3/-13.7) No glass

N: P-2352 (12.0/-13.4) Ranch glass

F: P-2357 (16.0/-17.7) Colonial glass

F: P-2358 (18.0/-22.7) Colonial glass

T: P-2804 (18.4/-22.7) Colonial glass

IW: P-3348 (23.3/-28.0) Ranch glass

F: P-2368 (23.3/-28.0) Colonial / Ranch glassT: P-2806 (23.3/-28.0) Colonial / Ranch glassN: P-2359 (25.6/-28.5)

Colonial glass

IR: P-3321 (29.7/-33.1)IR: P-2416 (30.0/-33.5)N: P-2360 (29.7/-33.1)

Colonial glassIW: P-3331 (29.7/-33.1)

Colonial glassIW: P-2904 (29.7/-33.1)

Colonial glassF: P-2369 (29.7/-33.1)

Colonial glassF: P-2370 (29.7/-33.1)

Colonial glassF: P-2419 (29.3/-32.6)

Colonial glass

IR: P-3318 (39.3/-43.8)D: P-3307 (45.0/-52.0)T: P-2907 (45.0/-52.0)IR: P-3361 (47.3/-47.3)

18’ Wide

N: P-2354 (12.0/-13.4) Colonial / Ranch glassN: P-2367 (12.0/-13.4) Colonial / Ranch glass

N: P-2362 (15.2/-16.9) Colonial glass

F: P-2417 (16.0/-18.0) Colonial glass

IW: P-3349 (17.7/-19.7) Ranch glass

IW: P-3333 (23.5/-26.2) Colonial glass

T: P-2805 (26.4/-29.4) Colonial glass

N: P-2363 (29.7/-36.0) Colonial glass

IR: P-3317 (37.4/-41.7)T: P-2905 (37.4/-41.7)

D: P-3308 (43.5/-50.0)T: P-2908 (43.5/-50.0)

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

TradeMark™

The combination of durable, 24-gauge steel, defined raised panel styling and authentic woodgrain texture gives your home curb appeal with TradeMark steel garage doors. Add charm with colonial or ranch panels, or for a distinctive look on your home, choose the carriage house option. Optional polystyrene insulation can be added to provide additional comfort and help keep your garage quieter. TradeMark doors are available in both post and strut designs.

"For As Long As You Own Your Home," against rust.Certain restrictions apply to corrosive airborne substances.

Door Sections*

6.6 with optional insulation

R-value

Hardware: 6 yearsSprings: 3 years

Hardware/Springs*

*See www.raynor.com/products for complete Limited Warranty details.

Page 19: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

19

TradeMark - JULY 2020 UPDATES

2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 210 210+

9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

9’ WideN: P-2392 (12.8/14.5) Colonial / Ranch glass

F: P-2300 (18.5/-20.9) Colonial / Ranch glass

F: P-2301 (24.8/-28.0) Colonial / Ranch glassT: P-2803 (24.8/-28.0) Colonial / Ranch glass

F: P-2301 (31.0/-35.1) Colonial glass (3) stilesT: P-2803 (24.8/-28.0) Colonial glass (3) stiles

IW: P-3348 (36.6/-41.1) Ranch glass

IR: P-3321 (41.6/-47.1)IW: P-3322 (41.6/-47.1)

Colonial glassT: P-2903 (41.6/-47.1)

Colonial glass

D: P-3307 (65.0/-75.0)T: P-2907 (65.0/-75.0)

10’ WideN: P-2324 (22.8/-25.8)

Colonial glassN: P-2325 (26.7/-30.2)

Colonial glassD: P-3307 (56.4/-65.1)

12’ WideD: P-3307 (56.4/-65.1)T: P-2907 (56.4/-65.1)

16’ Wide

N: P-2326 (12.3/-13.7) No glass

N: P-2352 (12.0/-13.4) Ranch glass

F: P-2357 (16.0/-17.7) Colonial glass

F: P-2358 (18.0/-22.7) Colonial glass

T: P-2804 (18.4/-22.7) Colonial glass

IW: P-3348 (23.3/-28.0) Ranch glass

F: P-2368 (23.3/-28.0) Colonial / Ranch glassT: P-2806 (23.3/-28.0) Colonial / Ranch glassN: P-2359 (25.6/-28.5)

Colonial glass

IR: P-3321 (29.7/-33.1)IR: P-2416 (30.0/-33.5)N: P-2360 (29.7/-33.1)

Colonial glassIW: P-3331 (29.7/-33.1)

Colonial glassIW: P-2904 (29.7/-33.1)

Colonial glassF: P-2369 (29.7/-33.1)

Colonial glassF: P-2370 (29.7/-33.1)

Colonial glassF: P-2419 (29.3/-32.6)

Colonial glass

IR: P-3318 (39.3/-43.8)D: P-3307 (45.0/-52.0)T: P-2907 (45.0/-52.0)IR: P-3361 (47.3/-47.3)

18’ Wide

N: P-2354 (12.0/-13.4) Colonial / Ranch glassN: P-2367 (12.0/-13.4) Colonial / Ranch glass

N: P-2362 (15.2/-16.9) Colonial glass

F: P-2417 (16.0/-18.0) Colonial glass

IW: P-3349 (17.7/-19.7) Ranch glass

IW: P-3333 (23.5/-26.2) Colonial glass

T: P-2805 (26.4/-29.4) Colonial glass

N: P-2363 (29.7/-36.0) Colonial glass

IR: P-3317 (37.4/-41.7)T: P-2905 (37.4/-41.7)

D: P-3308 (43.5/-50.0)T: P-2908 (43.5/-50.0)

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

ColorsStandard

White

Almond

Sandstone

Bronze

Brown

Optional

Raynor’s ColorWave™ features 1,500 Sherwin-Williams® next generation post paint system for your garage door.

Panel Options

Raised Colonial Recessed Colonial Grooved

Raised RanchFor impact window options please see page 23.

For non impact window options please see page 24.

The swatches shown on monitors and printed materials may vary from the actual color. For a true representation

of the color, visit your local Raynor Dealer.

Page 20: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

20

BuildMark - JULY 2020 UPDATES

2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 210 210+

9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

9’ WideN: P-2392 (12.8/14.5) Colonial / Ranch glass

F: P-2300 (18.5/-20.9) Colonial / Ranch glass

F: P-2301 (24.8/-28.0) Colonial / Ranch glass T: P-2803 (24.8/-28.0) Colonial / Ranch glass

F: P-2301 (31.0/-35.1) Colonial glass (3) stilesT: P-2803 (24.8/-28.0) Colonial glass (3) stiles

IW: P-3348 (36.6/-41.1) Ranch glass

IR: P-3321 (41.6/-47.1)IW: P-3322 (41.6/-47.1)

Colonial glassT: P-2903 (41.6/-47.1)

Colonial glass

10’ WideN: P-2324 (22.8/-25.8)

Colonial glassN: P-2325 (26.7/-30.2)

Colonial glass

16’ Wide

N: P-2326 (12.3/-13.7) No glass

N: P-2352 (12.0/-13.4) Ranch glass

F: P-2357 (16.0/-17.7) Colonial glass

F: P-2358 (18.0/-22.7) Colonial glass

T: P-2804 (18.4/-22.7) Colonial glass

N: P-2359 (25.6/-28.5) Colonial glass

IW: P-3348 (23.3/-28.0) Ranch glass

F: P-2368 (23.3/-28.0) Colonial / Ranch glassT: P-2806 (23.3/-28.0) Colonial / Ranch glass

IW: P-2419 (29.3/-32.6) Colonial glass

IR: P-3321 (29.7/-33.1)F: P-2416 (30.0/-33.5)N: P-2360 (29.7/-33.1)

Colonial glassIW: P-3331 (29.7/-33.1)

Colonial glassT: P-2904 (29.7/-33.1)

Colonial glassF: P-2369 (29.7/-33.1)

Colonial glassF: P-2370 (29.7/-33.1)

Colonial glass

IR: P-3318 (39.3/-43.8) IR: P-3361 (47.3/-47.3)

18’ Wide

N: P-2354 (12.0/-13.4) Colonial / Ranch glassN: P-2367 (12.0/-13.4) Colonial / Ranch glass

N: P-2362 (15.2/-16.9) Colonial glass

F: P-2417 (16.0/-18.0) Colonial glass

IW: P-3349 (17.7/-19.7) Ranch glass

IW: P-3333 (23.5/-26.2) Colonial glass

T: P-2805 (26.4/-29.4) Colonial glass

N: P-2363 (29.7/-36.0) Colonial glass

IR: P-3317 (37.4/-41.7)T: P-2905 (37.4/-41.7)

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

BuildMark®

This steel garage door design offers a traditional look at an affordable price. Choose from the time-honored ranch and colonial patterns or customize your garage with a carriage house design. Optional polystyrene insulation can be added to provide additional comfort and help keep your garage quieter. BuildMark doors are available in both u-bar and box strut designs.

"For As Long As You Own Your Home," against rust.Certain restrictions apply to corrosive airborne substances.

Door Sections*

6.6 with optional insulation

R-value

Hardware: 6 yearsSprings: 3 years

Hardware/Springs*

*See www.raynor.com/products for complete Limited Warranty details.

Page 21: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

21

BuildMark - JULY 2020 UPDATES

2017 FLORIDA BUILDING CODE DESIGN LOADS FOR CATEGORY II OCCUPANCY

Wind speed in Miles Per Hour (MPH) is for reference purposes only: reference the wind speed conversion charts for exact Design Loads or local Authority Having Jurisdiction (AHJ) to insure the door being specified meets the required Design Loads. Wind speeds in the charts are Ultimate Design Wind Speeds for 2017 Florida Building Code (FBC) Exposure B. Doors are rated by Design Loads, not Miles Per Hour. Design pressures may vary between door line. Refer to drawings for exact design load pressures.

Door Size MPH 110 115 120 130 140 150 160 170 180 190 200 210 210+

9’ x 7’ EXP B 11.4/-12.9 12.6/-14.2 13.7/-15.5 16.1/-18.2 18.5/-20.9 21.3/-24.1 24.3/-27.5 27.6/-31.2 30.6/-34.6 34.2/-38.6 38.0/-43.0

16’ X 7’ EXP B 10.9/-12.2 12.0/-13.4 13.1/-14.6 15.5/-17.2 17.7/-19.7 20.4/-22.7 23.3/-26.0 26.4/-29.4 29.3/-32.6 32.7/-36.5 36.4/-40.6

9’ WideN: P-2392 (12.8/14.5) Colonial / Ranch glass

F: P-2300 (18.5/-20.9) Colonial / Ranch glass

F: P-2301 (24.8/-28.0) Colonial / Ranch glass T: P-2803 (24.8/-28.0) Colonial / Ranch glass

F: P-2301 (31.0/-35.1) Colonial glass (3) stilesT: P-2803 (24.8/-28.0) Colonial glass (3) stiles

IW: P-3348 (36.6/-41.1) Ranch glass

IR: P-3321 (41.6/-47.1)IW: P-3322 (41.6/-47.1)

Colonial glassT: P-2903 (41.6/-47.1)

Colonial glass

10’ WideN: P-2324 (22.8/-25.8)

Colonial glassN: P-2325 (26.7/-30.2)

Colonial glass

16’ Wide

N: P-2326 (12.3/-13.7) No glass

N: P-2352 (12.0/-13.4) Ranch glass

F: P-2357 (16.0/-17.7) Colonial glass

F: P-2358 (18.0/-22.7) Colonial glass

T: P-2804 (18.4/-22.7) Colonial glass

N: P-2359 (25.6/-28.5) Colonial glass

IW: P-3348 (23.3/-28.0) Ranch glass

F: P-2368 (23.3/-28.0) Colonial / Ranch glassT: P-2806 (23.3/-28.0) Colonial / Ranch glass

IW: P-2419 (29.3/-32.6) Colonial glass

IR: P-3321 (29.7/-33.1)F: P-2416 (30.0/-33.5)N: P-2360 (29.7/-33.1)

Colonial glassIW: P-3331 (29.7/-33.1)

Colonial glassT: P-2904 (29.7/-33.1)

Colonial glassF: P-2369 (29.7/-33.1)

Colonial glassF: P-2370 (29.7/-33.1)

Colonial glass

IR: P-3318 (39.3/-43.8) IR: P-3361 (47.3/-47.3)

18’ Wide

N: P-2354 (12.0/-13.4) Colonial / Ranch glassN: P-2367 (12.0/-13.4) Colonial / Ranch glass

N: P-2362 (15.2/-16.9) Colonial glass

F: P-2417 (16.0/-18.0) Colonial glass

IW: P-3349 (17.7/-19.7) Ranch glass

IW: P-3333 (23.5/-26.2) Colonial glass

T: P-2805 (26.4/-29.4) Colonial glass

N: P-2363 (29.7/-36.0) Colonial glass

IR: P-3317 (37.4/-41.7)T: P-2905 (37.4/-41.7)

N Tested But Not Certified F Florida Approved IR Impact Rated IW Impact Rated With Windows D Dade Co. Approved T Texas Dept. of Insurance Approved *P-xxxx = Drawing Number

Panel Options

Raised Colonial Recessed Colonial Grooved

Raised Ranch Flush

For impact window options please see page 23. For non impact window options please see page 24.

The swatches shown on monitors and printed materials may vary from the actual color. For a true representation

of the color, visit your local Raynor Dealer.

ColorsStandard

White

Almond

Desert Tan

Sandstone

Brown

Black

Painted Woodtone Options

Optional Post Paint Finish

Raynor’s ColorWave™ features 1,500 Sherwin-Williams® next generation post paint system for your garage door.

Mocha WalnutAuburn

Page 22: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

Hurricane Ready™ Reinforcing SystemRaynor provides a wide range of residential garage door models that meet the demands of the most rigorous wind load or impact rating guidelines. Raynor wind load systems meet or exceed the Florida Building Code (FBC) and are tested to ANSI/DASMA 108 & 115. Additionally, Raynor offers several models that meet Miami-Dade product requirements (TAS 201, 202, 203).

Horizontal Trussing

Raynor Hurricane Ready reinforcing systems utilize horizontal trussing, made from high-tensile steel box struts or u-bars, to create a door system built to withstand hurricane force winds.

Single or double end stiles are provided depending on wind load specifications. Both feature Raynor's heavy-duty diamond hinges.

Raynor's box strut design (Patent Pending) features a yellow cap at each end for safety and visibility.

Raynor's high-strength rollers are designed and tested to withstand hurricane force winds.

Vertical Post(s)

Raynor's hurricane post(s) are installed prior to a hurricane and provide strength right where you need it.

The top of the post is anchored to the header with heavy-duty galva-nized hardware.

The middle of the door is strapped to the post to prevent the door from being pulled out of the opening from negative wind forces.

The bottom of the post is pinned to the floor with heavy-duty galva-nized hardware.

22

Page 23: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

Impact WindowsRaynor's impact and wind load rated windows are made from tough lightweight polycarbonate material that is durable, UV and scratch resistant, and housed in a colonial sized extruded aluminum frame. Available for BuildMark®, TradeMark™, ShowCase™ and Masterpiece™ doors.

Aspen™ AP138 & AP200

Color OptionsAspen™ Colors

White

Almond

Desert Tan

Sandstone

Bronze

Brown

Slate

Charcoal

Black

*For woodtone doors

Insert OptionsAspen™AP138 & AP200

Clear Colonial Clear Ranch

Snap-In InsertsColonial Ranch

Sherwood Sunburst Ranch

Prairie Prairie Ranch

Cathedral Arched Stockbridge Ranch

Waterton Waterton Ranch

Cascade Cascade Ranch

Stockton Stockton Ranch

Stockbridge Ranch Arched Stockton Ranch

Sunburst 4

Sunburst 5

Sunburst 6

Sunburst 7

Sunburst 8

Sunburst 9

Sunray (4 panel)

Berkshire

Breckenridge

BuildMark™ & TradeMark®

Color OptionsBuildMark® and TradeMark™ Colors

White

Almond

Desert Tan

Sandstone

Bronze

Brown

Black

*For woodtone doors

Insert OptionsBuildMark® and TradeMark™

Clear Colonial Clear Ranch

Snap-In InsertsColonial Ranch

Sherwood Sunburst Ranch

Prairie Prairie Ranch

Cathedral Arched Stockbridge Ranch

Waterton Waterton Ranch

Cascade Cascade Ranch

Stockton Stockton Ranch

Stockbridge Ranch Arched Stockton Ranch

Sunburst 4

Sunburst 5

Sunburst 6

Sunburst 7

Sunburst 8

Sunburst 9

Sunray (4 panel)

Berkshire

Breckenridge

ShowCase™Color Options

White

Almond

Insert Options

ShowCase™

Snap-In Inserts

Cathedral Cascade Stockton

Sunburst 4 Sherwood

Auburn Mocha Walnut

23

Page 24: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

24

Non-Impact WindowsAspen™ AP200LVSnap-In Inserts

Arched 4 Pane - Arched

Square 4 Pane - Square

Two Piece Arched 4 Pane - Two Piece Arched

4-Over-4 - Arched Wrought Iron - Arched

4-Over-4 - Square Wrought Iron - Square

4-Over-4 - Two Piece Arched Wrought Iron - Two Piece Arched

Peakview

Mission Vista

Spring Line

Revival Arch

Non-Impact GlassAspen™ AP200LV, AP200, AP138, TradeMark™, BuildMark®

Clear

Obscure

Satin

RockCreeke™

Clear

Rain

Aspen™ AP200, AP138, TradeMark™, BuildMark®

Snap-In Inserts

Clear Colonial Clear Ranch

Sunburst Ranch Sherwood

Prairie Ranch Prairie

Arched Stockbridge Ranch Cathedral

Waterton Ranch Waterton

Cascade Ranch Cascade

Stockton Ranch Stockton

Stockbridge Ranch Arched Stockton Ranch

Sunburst 4 Sunburst 5

Sunburst 6

Sunburst 7

Sunburst 8

Sunburst 9

Sunray (4 panel)

Berkshire

Breckenridge

Page 25: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

RockCreeke™ Window OptionsOur beautiful window designs put the perfect finishing touch on your new Raynor RockCreeke garage door.

1 pane 2 over 2 3 pane 3 over 3 3 over 3 arched

1 pan arched 4 pane 4 over 4 4 over 4 arched

25

Masterpiece™ and ShowCase™ Window OptionsArtistic GlassClear Beveled

Clear Diamond Colonial Clear Diamond Ranch Clear Prairie Colonial Clear Prairie Ranch

Frosted Beveled

Frosted Diamond Colonial Frosted Diamond Ranch Frosted Prairie Colonial Frosted Prairie Ranch

Dimensions GlassFrosted and Beveled with Caming

Regency Colonial Antique Ranch Oval/Diamond Frost Ranch Black Caming

Standard Glass & Snap-In InsertsDress up our clear and obscure windows with a variety of snap in inserts.

Plain Ranch Arched Stockton Ranch Plain Colonial Cascade Colonial

Stockton Ranch Prairie Ranch Sherwood Colonial Sunburst Colonial

Cascade Ranch Stockton Colonial Cathedral Colonial

Sunray Ranch Berkshire Ranch

Window designs shown may not be available on all sizes or models.

Page 26: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

26

Hardware OptionsDecorative HardwareDecorative handles and straps are optional on Aspen™, Eden Coast by Raynor®, RockCreeke™, Masterpiece™, ShowCase™, TradeMark™, and BuildMark® doors.

Handles

Cast Lift Handle Fleur-de-Lis 6131100

Cast Pull Handle Fleur-de-Lis 6131117

Cast Lift Handle Spear 6131115

Cast Pull Handle Spear 6131116

Cast Pull Handle Colonial 6131113

Stamped Lift Handle Spade 6131101

Stamped Pull Handle Spade 6131102

Low Profile Stamped Bean Handles 2/pack 6130498

Low Profile Stamped HandleFleur-de-Lis 2/pack 6130499

Magnetic Sets

Manor Handle & Strap Kit 4051100 Mission Handles &

Strap Kit 4051101 Colonial Handle & Strap Kit 4051102

Straps

Stamped 16” Hinge Spade (2” High) 6131105

Stamped 16” Hinge Narrow Spade (1⅝” High) 6131111

Cast 16” Hinge Colonial 6131114

Stamped 24” Hinge Spade 6131106

Cast 16” Hinge Spear 6131104

Cast 16” Hinge Assembly Spear 6131103

Stamped 17” Bean Straps 4/pack 6130491

Stamped 17” Fleur-de-Lis Straps 4/pack 6130492

HardwareGalvanized steel hardwareGalvanized hardware comes standard on Aspen™, RockCreeke™, Raynor StyleView™, ShowCase™, TradeMark™ and BuildMark® doors.

EnduraCote™ hardwareThe EnduraCote Hardware System features extended-life black powder coated torsion springs and white powder coated track and hinges. Heavy-duty nylon rollers, with steel ball bearings, also help to provide superior noise reduction.

EnduraCote comes standard on Masterpiece™ doors and is optional on Aspen™, RockCreeke™ and Raynor StyleView™ doors.

Page 27: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

27

Garage Door OpenersRaynor offers a full line of residential openers, featuring a variety of horsepower and configuration options. All of our operators feature MyQ™technology, a patented, two-way communication system that allows users to open and close the garage door and manage other household devices from anywhere in the world via a Smart Phone. Ask your authorized Raynor dealer about our residential openers, and select the ideal Raynor opener for your home.

Premium

Deluxe

Standard

Prodigy II® Providing an exceptional solution for garages that don’t allow for a traditional garage door opener. Prodigy II is a space-saving, wall-mounted jackshaft opener. The ultra-quiet 24V DC motor-operated Prodigy II mounts easily on the wall beside the garage door.

Prodigy II® with WiFi® Space saving and heavy lifting, the Raynor Prodigy II with WiFi is the ultimate garage access solution. This opener comes fully equipped with must-have features including built in WiFi for smartphone control, MyQ® Remote LED light, integrated battery backup, and the automatic garage door lock.

General II with WiFi® General II with WiFi® features the quiet reliability of a belt drive opener combined with a battery backup. The General II with WiFi® features MyQ™ technology, a patented, two-way communi-cation system that allows users to open and close the garage door and manage other household devices from anywhere in the world via a Smart Phone. Standard integrated WiFi® provides an all-in-one solution with free apps for Apple and Android.

Sentinel™ Sentinel is built with an integrated HD camera which lets you see who is coming and going in your garage through a live feed or recorded event. Recording begins when motion is detected, even at night thanks to built-in night vision. Want to talk to anyone you see in your garage? This opener is also equipped with 2-way audio for real time communication. Ensure your family and possessions are safe and secure with a reliable garage door opener that’s simple to use, dependable and myQ® connected.

Admiral II with WiFi® Admiral II with WiFi® offers the quiet reliability of a DC belt driven opener, combined with a battery backup. The Admiral II with WiFi® features MyQ™ technology, a patented, two-way communi-cation system that allows users to open and close the garage door and manage other household devices from anywhere in the world via a Smart Phone. Standard integrated WiFi® provides an all-in-one solution with free apps for Apple and Android.

Ultra II with WiFi® Designed to handle even the heaviest doors, the Raynor Ultra II with WiFi® combines a chain drive with a 3/4 horsepower motor. A rugged I-beam rail and chasis support gives added strength and reliable operation. A dual-drive sprocket allows the opener’s speed to be adjusted to optimize door and opener performance. Standard with integrated WiFi provides an all-in-one solution with free apps for Apple and Android.

Aviator II® with WiFi® The Aviator II garage door opener is powered by a 1/2 hp motor with a one-piece solid belt drive rail, for quiet-running performance. Standard integrated WiFi® provides an all-in-one solution with free apps for Apple and Android.

Pilot II® with WiFi® Reliable, effortless operation comes with the Pilot II with WiFi garage door opener, which is powered by a 1/2 hp motor with an industrial-strength chain drive. Standard integrated WiFi® provides an all-in-one solution with free apps for Apple and Android.

Corporal II™ with WiFi® A smooth-running 1/2 hp chain drive opener, the Corporal II with WiFi is dependable and secure. Designed for those who want an excellent combination of value and functionality. Standard integrated WiFi® provides an all-in-one solution with free apps for Apple and Android.

Airman II™ with WiFi® A smooth-running 1/2 hp belt drive opener, the Airman II with WiFi is dependable and secure. Designed for those who want an excellent combination of value and functionality with that everyday dependability of a Raynor opener. Standard integrated WiFi® provides an all-in-one solution with free apps for Apple and Android.

Sergeant II™ with WiFi® Designed for the consumer who values reliability, security and connectivity. The Sergeant II with WiFi has built in technology and is equipped with battery backup to keep homeowners safe and secure while at home or away. This chain drive system offers quiet operation with industrial strength and is built to last. Standard integrated WiFi® provides an all-in-one solution with free apps for Apple and Android.

Capable

Capable

Capable

Page 28: 2902893 Wind-Load-Overview 0820The design wind load pressure rating of a door as expressed in PSF (pounds per square foot). The design pressure of the door must equal or exceed the

Exclusively Distributed by:

Professional Installation & ServiceDepend on your Raynor DealerWhen you select Raynor, you’re not just getting a superior garage door - you’re also getting professional garage door installation and service expertise.

Every Raynor garage door is installed by a trained Raynor professional, and that means added benefits for you. First, you won’t have to deal with it yourself. Second, because it’s done right the first time, your door will deliver performance and reliability from the day it’s installed. Your technician will check your door for everything from safety to performance and appearance. Trust your Raynor garage door to someone who knows it better than anyone else, your professional Raynor Dealer.

Follow Us

©2020 Raynor 2902893 10/201-800-4-RAYNOR (472-9667) • www.raynor.com

Hurricane Ready™