25,(17$7,21 71 - Mackay Council · The copyright and ownership of the drawings is to be assigned to...

5
The copyright and ownership of the drawings is to be assigned to Telstra Telstra Wireless Operations Template - 017866P02 issued Feb 2009 PRELIMINARY MOBILE NETWORK SITE 284142 SOUTH PAGET Q110590 S1 INDEX SITE LOCALITY AND ACCESS 55 DOZER DRIVE, PAGET, QLD 4740 NOTES: 1. ALL FEEDER ACCESS POINTS ON THE STRUCTURE MUST BE BIRD PROOFED AS PER EXTERNAL PLANT POLICY 003615. 2. THIS DRAWING SET IS A PRELIMINARY DRAWING ONLY AND IS ISSUED FOR COMMENT. IT IS NOT A DETAILED SURVEY / STRUCTURAL DRAWING AND THEREFORE COULD BE SUBJECT TO CHANGE. PROPOSED TELSTRA LEASE AREA PROPERTY DESCRIPTION SITE LAYOUT SCALE 1:2000 SITE ACCESS SCALE 1:10000 SITE STRUCTURE CO-ORDINATES +$1' +(/' *36 5($',1* P CENTRE OF POLE GDA 94 -21.19155 GDA 94 149.15733 LOCALITY PLAN NOT TO SCALE COPYRIGHT C WHEREIS REGISTERED TRADEMARK OF SENSIS PTY LTD. R PART OF LOT 51 ON SP224085 PARISH OF HOWARD COUNTY OF CARLISLE PROPERTY DESCRIPTION RFNSA SITE No. 4740056 DOZER DR LOT 50 SP224085 DOZER DR MERCHANT ST CATEPILLAR DR TURBO DR DIESEL DR BRUCE HWY FARRELLYS RD SOUTHGATE DR FARRELLYS RD CONNORS RD 0 100m 20m 20m 40m 60m 80m LOT 51 SP224085 LOT 49 SP224085 LOT 48 SP224085 LOT 37 SP224085 LOT 36 SP224085 LOT 35 SP224085 LOT 34 SP230183 LOT 106 SP224085 EASEMENT C SP198680 LOT 15 SP234301 MERCHANT STEET DOZER DRIVE LOT 107 SP224037 CRICHTONS RD LOT 103 SP193948 CONNORS ROAD CRICHTONS ROAD LOT 22 SP130195 (NORTH COAST RAILWAY) PROPOSED TELSTRA SITE. REFER TO SHEET S1-1 FOR DETAILS EXISTING INDUSTRIAL BUILDINGS TYP. PROPOSED INDUSTRIAL BUILDING UNDER CONSTRUCTION (BY OTHERS) INDICATES OUTLINE OF PROPOSED LANDSCAPING (BY OTHERS) PROPOSED U/G POWER FROM BUILDING MSB. ACCESS TO PROPOSED TELSTRA SITE VIA INDUSTRIAL BUILDING DRIVEWAY OFF DOZER DRIVE

Transcript of 25,(17$7,21 71 - Mackay Council · The copyright and ownership of the drawings is to be assigned to...

Page 1: 25,(17$7,21 71 - Mackay Council · The copyright and ownership of the drawings is to be assigned to Telstra Telstra Wireless Operations Template - 017866P02 issued Feb 2009 PRELIMINARY

The copyright and ownership of the drawings is to be assigned to Telstra

Telst

ra W

ireles

s Ope

ratio

ns T

empla

te - 0

1786

6P02

issu

ed F

eb 20

09 PRELIMINARY

MOBILE NETWORK SITE 284142SOUTH PAGET

Q110590 S1INDEX

SITE LOCALITY AND ACCESS55 DOZER DRIVE, PAGET, QLD 4740

NOTES:1. ALL FEEDER ACCESS POINTS ON THE STRUCTURE MUST BE BIRD

PROOFED AS PER EXTERNAL PLANT POLICY 003615.2. THIS DRAWING SET IS A PRELIMINARY DRAWING ONLY AND IS ISSUED

FOR COMMENT. IT IS NOT A DETAILED SURVEY / STRUCTURAL DRAWINGAND THEREFORE COULD BE SUBJECT TO CHANGE.

PROPOSED TELSTRA LEASE AREA

PROPERTY DESCRIPTION

SITE LAYOUTSCALE 1:2000

SITE ACCESS SCALE 1:10000

SITE STRUCTURE CO-ORDINATESHAND HELD GPS READING ± 10m,

CENTRE OF POLEGDA 94

-21.19155GDA 94

149.15733

LOCALITY PLANNOT TO SCALE

COPYRIGHT C WHEREIS REGISTERED TRADEMARK OF SENSIS PTY LTD.R

PART OF LOT 51 ON SP224085PARISH OF HOWARDCOUNTY OF CARLISLE

PROPERTY DESCRIPTION

RFNSA SITE No. 4740056

DOZER DR

LOT 50SP224085

DOZE

R DR

MERCHANT ST

CATE

PILL

AR D

R

TURBO DR

DIES

EL D

R

BRUC

E HW

Y

FARRELLYS RD SOUT

HGAT

EDR

FARRELLYS RD

CONN

ORS

RD

0 100m20m 20m 40m 60m 80m

LOT 51SP224085

LOT 49SP224085

LOT 48SP224085

LOT 37SP224085

LOT 36SP224085

LOT 35SP224085

LOT 34SP230183

LOT 106SP224085

EASEMENT CSP198680

LOT 15SP234301

MERCHANT STEET

DOZE

R DR

IVE

LOT 107SP224037

CRICHTONS RD

LOT

103

SP19

3948

CONN

ORS

ROAD

CRICHTONS ROADLO

T 22

SP1

3019

5(N

ORTH

COA

ST R

AILW

AY)

PROPOSED TELSTRASITE. REFER TO SHEETS1-1 FOR DETAILS

EXISTING INDUSTRIAL BUILDINGS TYP.

PROPOSED INDUSTRIAL BUILDING UNDER CONSTRUCTION(BY OTHERS)

INDICATES OUTLINE OFPROPOSED LANDSCAPING(BY OTHERS) PROPOSED U/G POWERFROM BUILDING MSB.

ACCESS TO PROPOSEDTELSTRA SITE VIA INDUSTRIALBUILDING DRIVEWAY OFFDOZER DRIVE

tracyh
Received (Manual Date)
Page 2: 25,(17$7,21 71 - Mackay Council · The copyright and ownership of the drawings is to be assigned to Telstra Telstra Wireless Operations Template - 017866P02 issued Feb 2009 PRELIMINARY

The copyright and ownership of the drawings is to be assigned to Telstra

Telst

ra W

ireles

s Ope

ratio

ns T

empla

te - 0

1786

6P02

issu

ed F

eb 20

09 PRELIMINARY

MOBILE NETWORK SITE 284142SOUTH PAGET

Q110590 S1-1INDEX

SITE SETOUT PLAN55 DOZER DRIVE, PAGET, QLD 4740

LOT 51SP224085

LOT 106SP224085

EASEMENT CSP198680 SITE SETOUT PLAN

SCALE 1:1000 1m 2m 3m 4m 5m1m

PROPOSED TELSTRA450W CABLE LADDER

PROPOSED TELSTRA 30m MONOPOLE

PROPOSED TELSTRA LOW IMPACTEQUIPMENT SHELTER TYPE ICS Mk 3.2(REGION C - 3280 L x 2280 W x 2995 H)

11000(PROPOSED TELSTRA LEASE AREA)

7000

(PRO

POSE

D TE

LSTR

A LE

ASE

AREA

)

==

35002720

32801500

MONOPOLE

MONO

POLE

NOTES:1. ALL FEEDER ACCESS POINTS ON THE STRUCTURE MUST BE BIRD

PROOFED AS PER EXTERNAL PLANT POLICY 003615.2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS SPECIFIED OTHERWISE.3. THIS DRAWING SET IS A PRELIMINARY DRAWING ONLY AND IS ISSUED

FOR COMMENT. IT IS NOT A DETAILED SURVEY / STRUCTURAL DRAWINGAND THEREFORE COULD BE SUBJECT TO CHANGE.

PROPOSED TELSTRA LEASE AREA

PROPERTY BOUNDARY PROP

ERTY

BOU

NDAR

Y

TOP OF EXISTING BANK

BOTTOM OF EXISTING BANK

PROPOSED INDICATIVE TELSTRA UNDERGROUND POWER. EXACTSOURCE AND ROUTE TO BE CONFIRMED AT DETAILED DESIGNPROPOSED INDICATIVE TELSTRA FIBRE LINK FROMEXISTING TELSTRA FIBRE PIT. TO BE CONFIRMED AFTERDETAILED INVESTIGATION BY TELSTRA WIDEBAND

PROPOSED TELSTRA VEHICLE BOLLARDSAROUND TELSTRA LEASE AREA AS SHOWN

PROPOSED LANDSCAPING ANDBIO-RETENTION BASIN (BY OTHERS)

1000

EXISTING ELECTRICALCABLE AND CONDUIT 500mmFROM BOUNDARY AND600mm DEEP

APPROX 7750

LOT 103SP193948

1

3

2

A1

A2

ANTENNA LAYOUT AT 31.4mSCALE 1:25

RRU LAYOUT AT 29.4 & 28.4mSCALE 1:25

R1R4

(BELOW)

R2

R5(BELOW)

R3

R6(BELOW)

0 1000500 500

A3

PROPOSED TELSTRA PANELANTENNAS (3 OFF A1, A2 & A3)ON PROPOSED MOUNTS

PROPOSED TELSTRA RRU'S(6 OFF R1, R2, R3, R4, R5 & R6)DOUBLE STACKED ONPROPOSED MOUNTS

PROPOSED TELSTRA HEADFRAMEWITH ARMS AND OUTER FRAMEREMOVED

HEADFRAME

ORIENTATION 80°TN

Page 3: 25,(17$7,21 71 - Mackay Council · The copyright and ownership of the drawings is to be assigned to Telstra Telstra Wireless Operations Template - 017866P02 issued Feb 2009 PRELIMINARY

The copyright and ownership of the drawings is to be assigned to Telstra

Telst

ra W

ireles

s Ope

ratio

ns T

empla

te - 0

1786

6P02

issu

ed F

eb 20

09 PRELIMINARY

MOBILE NETWORK SITE 284142SOUTH PAGET

Q110590 S1-2INDEX

FUTURE ANTENNA & RRU LAYOUT55 DOZER DRIVE, PAGET, QLD 4740

SCALE 1:50

A2

1

2

3

A1

A3HEADFRAME

ORIENTATION 80°TN

-

-

-

-

-

-

-

-

-

A4

A5A8

A11A7

A10

A6

A9

A12

0 2500500

FUTURE ANTENNA & RRU LAYOUT

C/L CURRENTLY PROPOSED TELSTRA PANEL ANTENNAS

C/L CURRENTLY PROPOSED TELSTRA RRU'S(3 OFF R1, R2 & R3) TO REMAIN

PART FUTURE SOUTH ELEVATIONSCALE 1:50

0 2500500

R8 R7

R9

FUTURE TELSTRA RRUS (3 OFF R7,R8 & R9) ON PROPOSED MOUNTS

FUTURE TELSTRA PANEL ANTENNAS (9 OFF A4,A5, A6, A7, A8, A9, A10, A11 & A12) MOUNTED ONFUTURE HEADFRAME EXTENSION

CURRENTLY PROPOSED TELSTRA PANELANTENNAS (3 OFF A1, A2 & A3) RELOCATEDTO FUTURE HEADFRAME EXTENSION

FUTURE EXTENSION OF TELSTRAHEADFRAME WITH ADDITION OFSUPPORT ARMS AND OUTER FRAME

NOTE:1. INITIAL CONSTRUCTION AT SITE TO HAVE 3 OFF PROPOSED ANTENNAS ON

ANTENNA MOUNTS FIXED TO HEADFRAME WITH SUPPORT ARMS AND OUTERFRAME REMOVED, REFER SHEET S1-1. FUTURE UPGRADE OF SITE TORE-INSTALL SUPPORT ARMS AND OUTER FRAME WITH ANTENNA MOUNTS ASSHOWN. FOR PROPOSED AND FUTURE ANTENNA DETAILS REFER SHEET S3-1

C/L CURRENTLY PROPOSED TELSTRA RRU'S(3 OFF R4, R5 & R6) TO REMAIN

C/L CURRENTLY PROPOSED RRU JUNCTION BOXES(3 OFF) TO REMAIN

(3 OFF A1, A2 & A3) RELOCATED TO FUTURE HEADFRAME EXTENSIONC/L FUTURE TELSTRA PANEL ANTENNAS (9 OFF A4, A5, A6, A7, A8, A9,A10, A11 & A12)

C/L FUTURE TELSTRA RRU'S (3 OFF R7, R8 & R9)

Page 4: 25,(17$7,21 71 - Mackay Council · The copyright and ownership of the drawings is to be assigned to Telstra Telstra Wireless Operations Template - 017866P02 issued Feb 2009 PRELIMINARY

PRELIMINARY

The copyright and ownership of the drawings is to be assigned to Telstra

Telst

ra W

ireles

s Ope

ratio

ns T

empla

te - 0

1786

6P02

issu

ed F

eb 20

09

MOBILE NETWORK SITE 284142SOUTH PAGET

Q110590 S3INDEX

SITE ELEVATION55 DOZER DRIVE, PAGET, QLD 4740

NOTES:1. ALL FEEDER ACCESS POINTS ON THE STRUCTURE MUST BE BIRD

PROOFED AS PER EXTERNAL PLANT POLICY 003615.2. THIS DRAWING SET IS A PRELIMINARY DRAWING ONLY AND IS ISSUED

FOR COMMENT. IT IS NOT A DETAILED SURVEY / STRUCTURAL DRAWINGAND THEREFORE COULD BE SUBJECT TO CHANGE.

3. FOR EME SIGNS NOTED THUS #X REFER TO 005486 FOR DETAILS.4. FOUNDATIONS ARE SHOWN INDICATIVE ONLY. FINAL DESIGN IS SUBJECT

TO RESULTS OF GEOTECHNICAL INVESTIGATION.

SOUTH ELEVATIONSCALE 1:125

C/L PROPOSED TELSTRA PANEL ANTENNAS (3 OFF A1, A2 & A3)

PROPOSED TELSTRAHEADFRAME WITH ARMS ANDOUTER FRAME REMOVED

PROPOSED TELSTRA 30.0mMONOPOLE

PROPOSED TELSTRA FEEDERSTO RUN INSIDE MONOPOLE

PROPOSED TELSTRA 450WCABLE LADDER

PROPOSED TELSTRA EQUIPMENTSHELTER

# 2 BEHIND EACHPANEL ANTENNA

5.0m AGL# 6

PROPOSED FOUNDATIONS SHOWNINDICATIVELY TO BE CONFIRMEDAT DETAILED DESIGN STAGE

NOTE: THIS DRAWING TO BE READ IN CONJUNCTION WITH SHEET S3-1

C/L PROPOSED TELSTRA RRU'S (3 OFF R1, R2 & R3)

C/L PROPOSED TELSTRA RRU'S (3 OFF R4, R5 & R6)

PROPOSED BOUNDARY FENCE AS PARTOF INDUSTRIAL BUILDING UNDERCONSTRUCTION (BY OTHERS)

C/L PROPOSED RRU JUNCTION BOXES (3 OFF)

Page 5: 25,(17$7,21 71 - Mackay Council · The copyright and ownership of the drawings is to be assigned to Telstra Telstra Wireless Operations Template - 017866P02 issued Feb 2009 PRELIMINARY

PRELIMINARY

The copyright and ownership of the drawings is to be assigned to Telstra

Telst

ra W

ireles

s Ope

ratio

ns T

empla

te - 0

1786

6P02

issu

ed F

eb 20

09

MOBILE NETWORK SITE 284142SOUTH PAGET

Q110590 S3-1INDEX

ANTENNA CONFIGURATION TABLE55 DOZER DRIVE, PAGET, QLD 4740

ANTENNANo

ANTENNA TYPE &SIZE H x W x D

ANTENNAHEIGHT

C/L A.G.L.

ANTENNASTATUS

SECTOR NO.& SYSTEM

PHYSICALANTENNABEARING (°T)

A1 31.40m 80°PROPOSED

S1: WCDMA850S1: WCDMA850

S1: LTE1800S1: LTE1800

S1: LTE1800S1: LTE1800ARGUS CVVPX310B2 PANEL

2494 x 353 x 209

A2 31.40m 200°PROPOSED

S2: WCDMA850S2: WCDMA850

S2: LTE1800S2: LTE1800

S2: LTE1800S2: LTE1800ARGUS CVVPX310B2 PANEL

2494 x 353 x 209

A3 31.40m 320°PROPOSED

S3: WCDMA850S3: WCDMA850

S3: LTE1800S3: LTE1800

S3: LTE1800S3: LTE1800ARGUS CVVPX310B2 PANEL

2494 x 353 x 209

A4 31.40m 80°FUTURE

--

--

--ARGUS CVVPX310B2 PANEL

2494 x 353 x 209

A5 31.40m 200°FUTUREARGUS CVVPX310B2 PANEL2494 x 353 x 209

A6 31.40m 320°FUTUREARGUS CVVPX310B2 PANEL2494 x 353 x 209

A7 31.40m 80°FUTUREARGUS CVVPX310B2 PANEL2494 x 353 x 209

A8 31.40m 200°FUTUREARGUS CVVPX310B2 PANEL2494 x 353 x 209

A9 31.40m 320°FUTUREARGUS CVVPX310B2 PANEL2494 x 353 x 209

A10 31.40m 80°--

--

FUTUREARGUS VVPX310B1 PANEL1328 x 290 x 103

A11 31.40m 200°FUTUREARGUS VVPX310B1 PANEL1328 x 290 x 103

A12 31.40m 320°FUTUREARGUS VVPX310B1 PANEL1328 x 290 x 103

NOTE: THIS DRAWING TO BE READ IN CONJUNCTION WITH SHEET S3

NOTE: COMBINED AT 80W RU IN PROPOSED RBS6202*

*

*

*

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--