25,(17$7,21 71 - Mackay Council · The copyright and ownership of the drawings is to be assigned to...
Transcript of 25,(17$7,21 71 - Mackay Council · The copyright and ownership of the drawings is to be assigned to...
The copyright and ownership of the drawings is to be assigned to Telstra
Telst
ra W
ireles
s Ope
ratio
ns T
empla
te - 0
1786
6P02
issu
ed F
eb 20
09 PRELIMINARY
MOBILE NETWORK SITE 284142SOUTH PAGET
Q110590 S1INDEX
SITE LOCALITY AND ACCESS55 DOZER DRIVE, PAGET, QLD 4740
NOTES:1. ALL FEEDER ACCESS POINTS ON THE STRUCTURE MUST BE BIRD
PROOFED AS PER EXTERNAL PLANT POLICY 003615.2. THIS DRAWING SET IS A PRELIMINARY DRAWING ONLY AND IS ISSUED
FOR COMMENT. IT IS NOT A DETAILED SURVEY / STRUCTURAL DRAWINGAND THEREFORE COULD BE SUBJECT TO CHANGE.
PROPOSED TELSTRA LEASE AREA
PROPERTY DESCRIPTION
SITE LAYOUTSCALE 1:2000
SITE ACCESS SCALE 1:10000
SITE STRUCTURE CO-ORDINATESHAND HELD GPS READING ± 10m,
CENTRE OF POLEGDA 94
-21.19155GDA 94
149.15733
LOCALITY PLANNOT TO SCALE
COPYRIGHT C WHEREIS REGISTERED TRADEMARK OF SENSIS PTY LTD.R
PART OF LOT 51 ON SP224085PARISH OF HOWARDCOUNTY OF CARLISLE
PROPERTY DESCRIPTION
RFNSA SITE No. 4740056
DOZER DR
LOT 50SP224085
DOZE
R DR
MERCHANT ST
CATE
PILL
AR D
R
TURBO DR
DIES
EL D
R
BRUC
E HW
Y
FARRELLYS RD SOUT
HGAT
EDR
FARRELLYS RD
CONN
ORS
RD
0 100m20m 20m 40m 60m 80m
LOT 51SP224085
LOT 49SP224085
LOT 48SP224085
LOT 37SP224085
LOT 36SP224085
LOT 35SP224085
LOT 34SP230183
LOT 106SP224085
EASEMENT CSP198680
LOT 15SP234301
MERCHANT STEET
DOZE
R DR
IVE
LOT 107SP224037
CRICHTONS RD
LOT
103
SP19
3948
CONN
ORS
ROAD
CRICHTONS ROADLO
T 22
SP1
3019
5(N
ORTH
COA
ST R
AILW
AY)
PROPOSED TELSTRASITE. REFER TO SHEETS1-1 FOR DETAILS
EXISTING INDUSTRIAL BUILDINGS TYP.
PROPOSED INDUSTRIAL BUILDING UNDER CONSTRUCTION(BY OTHERS)
INDICATES OUTLINE OFPROPOSED LANDSCAPING(BY OTHERS) PROPOSED U/G POWERFROM BUILDING MSB.
ACCESS TO PROPOSEDTELSTRA SITE VIA INDUSTRIALBUILDING DRIVEWAY OFFDOZER DRIVE
The copyright and ownership of the drawings is to be assigned to Telstra
Telst
ra W
ireles
s Ope
ratio
ns T
empla
te - 0
1786
6P02
issu
ed F
eb 20
09 PRELIMINARY
MOBILE NETWORK SITE 284142SOUTH PAGET
Q110590 S1-1INDEX
SITE SETOUT PLAN55 DOZER DRIVE, PAGET, QLD 4740
LOT 51SP224085
LOT 106SP224085
EASEMENT CSP198680 SITE SETOUT PLAN
SCALE 1:1000 1m 2m 3m 4m 5m1m
PROPOSED TELSTRA450W CABLE LADDER
PROPOSED TELSTRA 30m MONOPOLE
PROPOSED TELSTRA LOW IMPACTEQUIPMENT SHELTER TYPE ICS Mk 3.2(REGION C - 3280 L x 2280 W x 2995 H)
11000(PROPOSED TELSTRA LEASE AREA)
7000
(PRO
POSE
D TE
LSTR
A LE
ASE
AREA
)
==
35002720
32801500
MONOPOLE
MONO
POLE
NOTES:1. ALL FEEDER ACCESS POINTS ON THE STRUCTURE MUST BE BIRD
PROOFED AS PER EXTERNAL PLANT POLICY 003615.2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS SPECIFIED OTHERWISE.3. THIS DRAWING SET IS A PRELIMINARY DRAWING ONLY AND IS ISSUED
FOR COMMENT. IT IS NOT A DETAILED SURVEY / STRUCTURAL DRAWINGAND THEREFORE COULD BE SUBJECT TO CHANGE.
PROPOSED TELSTRA LEASE AREA
PROPERTY BOUNDARY PROP
ERTY
BOU
NDAR
Y
TOP OF EXISTING BANK
BOTTOM OF EXISTING BANK
PROPOSED INDICATIVE TELSTRA UNDERGROUND POWER. EXACTSOURCE AND ROUTE TO BE CONFIRMED AT DETAILED DESIGNPROPOSED INDICATIVE TELSTRA FIBRE LINK FROMEXISTING TELSTRA FIBRE PIT. TO BE CONFIRMED AFTERDETAILED INVESTIGATION BY TELSTRA WIDEBAND
PROPOSED TELSTRA VEHICLE BOLLARDSAROUND TELSTRA LEASE AREA AS SHOWN
PROPOSED LANDSCAPING ANDBIO-RETENTION BASIN (BY OTHERS)
1000
EXISTING ELECTRICALCABLE AND CONDUIT 500mmFROM BOUNDARY AND600mm DEEP
APPROX 7750
LOT 103SP193948
1
3
2
A1
A2
ANTENNA LAYOUT AT 31.4mSCALE 1:25
RRU LAYOUT AT 29.4 & 28.4mSCALE 1:25
R1R4
(BELOW)
R2
R5(BELOW)
R3
R6(BELOW)
0 1000500 500
A3
PROPOSED TELSTRA PANELANTENNAS (3 OFF A1, A2 & A3)ON PROPOSED MOUNTS
PROPOSED TELSTRA RRU'S(6 OFF R1, R2, R3, R4, R5 & R6)DOUBLE STACKED ONPROPOSED MOUNTS
PROPOSED TELSTRA HEADFRAMEWITH ARMS AND OUTER FRAMEREMOVED
HEADFRAME
ORIENTATION 80°TN
The copyright and ownership of the drawings is to be assigned to Telstra
Telst
ra W
ireles
s Ope
ratio
ns T
empla
te - 0
1786
6P02
issu
ed F
eb 20
09 PRELIMINARY
MOBILE NETWORK SITE 284142SOUTH PAGET
Q110590 S1-2INDEX
FUTURE ANTENNA & RRU LAYOUT55 DOZER DRIVE, PAGET, QLD 4740
SCALE 1:50
A2
1
2
3
A1
A3HEADFRAME
ORIENTATION 80°TN
-
-
-
-
-
-
-
-
-
A4
A5A8
A11A7
A10
A6
A9
A12
0 2500500
FUTURE ANTENNA & RRU LAYOUT
C/L CURRENTLY PROPOSED TELSTRA PANEL ANTENNAS
C/L CURRENTLY PROPOSED TELSTRA RRU'S(3 OFF R1, R2 & R3) TO REMAIN
PART FUTURE SOUTH ELEVATIONSCALE 1:50
0 2500500
R8 R7
R9
FUTURE TELSTRA RRUS (3 OFF R7,R8 & R9) ON PROPOSED MOUNTS
FUTURE TELSTRA PANEL ANTENNAS (9 OFF A4,A5, A6, A7, A8, A9, A10, A11 & A12) MOUNTED ONFUTURE HEADFRAME EXTENSION
CURRENTLY PROPOSED TELSTRA PANELANTENNAS (3 OFF A1, A2 & A3) RELOCATEDTO FUTURE HEADFRAME EXTENSION
FUTURE EXTENSION OF TELSTRAHEADFRAME WITH ADDITION OFSUPPORT ARMS AND OUTER FRAME
NOTE:1. INITIAL CONSTRUCTION AT SITE TO HAVE 3 OFF PROPOSED ANTENNAS ON
ANTENNA MOUNTS FIXED TO HEADFRAME WITH SUPPORT ARMS AND OUTERFRAME REMOVED, REFER SHEET S1-1. FUTURE UPGRADE OF SITE TORE-INSTALL SUPPORT ARMS AND OUTER FRAME WITH ANTENNA MOUNTS ASSHOWN. FOR PROPOSED AND FUTURE ANTENNA DETAILS REFER SHEET S3-1
C/L CURRENTLY PROPOSED TELSTRA RRU'S(3 OFF R4, R5 & R6) TO REMAIN
C/L CURRENTLY PROPOSED RRU JUNCTION BOXES(3 OFF) TO REMAIN
(3 OFF A1, A2 & A3) RELOCATED TO FUTURE HEADFRAME EXTENSIONC/L FUTURE TELSTRA PANEL ANTENNAS (9 OFF A4, A5, A6, A7, A8, A9,A10, A11 & A12)
C/L FUTURE TELSTRA RRU'S (3 OFF R7, R8 & R9)
PRELIMINARY
The copyright and ownership of the drawings is to be assigned to Telstra
Telst
ra W
ireles
s Ope
ratio
ns T
empla
te - 0
1786
6P02
issu
ed F
eb 20
09
MOBILE NETWORK SITE 284142SOUTH PAGET
Q110590 S3INDEX
SITE ELEVATION55 DOZER DRIVE, PAGET, QLD 4740
NOTES:1. ALL FEEDER ACCESS POINTS ON THE STRUCTURE MUST BE BIRD
PROOFED AS PER EXTERNAL PLANT POLICY 003615.2. THIS DRAWING SET IS A PRELIMINARY DRAWING ONLY AND IS ISSUED
FOR COMMENT. IT IS NOT A DETAILED SURVEY / STRUCTURAL DRAWINGAND THEREFORE COULD BE SUBJECT TO CHANGE.
3. FOR EME SIGNS NOTED THUS #X REFER TO 005486 FOR DETAILS.4. FOUNDATIONS ARE SHOWN INDICATIVE ONLY. FINAL DESIGN IS SUBJECT
TO RESULTS OF GEOTECHNICAL INVESTIGATION.
SOUTH ELEVATIONSCALE 1:125
C/L PROPOSED TELSTRA PANEL ANTENNAS (3 OFF A1, A2 & A3)
PROPOSED TELSTRAHEADFRAME WITH ARMS ANDOUTER FRAME REMOVED
PROPOSED TELSTRA 30.0mMONOPOLE
PROPOSED TELSTRA FEEDERSTO RUN INSIDE MONOPOLE
PROPOSED TELSTRA 450WCABLE LADDER
PROPOSED TELSTRA EQUIPMENTSHELTER
# 2 BEHIND EACHPANEL ANTENNA
5.0m AGL# 6
PROPOSED FOUNDATIONS SHOWNINDICATIVELY TO BE CONFIRMEDAT DETAILED DESIGN STAGE
NOTE: THIS DRAWING TO BE READ IN CONJUNCTION WITH SHEET S3-1
C/L PROPOSED TELSTRA RRU'S (3 OFF R1, R2 & R3)
C/L PROPOSED TELSTRA RRU'S (3 OFF R4, R5 & R6)
PROPOSED BOUNDARY FENCE AS PARTOF INDUSTRIAL BUILDING UNDERCONSTRUCTION (BY OTHERS)
C/L PROPOSED RRU JUNCTION BOXES (3 OFF)
PRELIMINARY
The copyright and ownership of the drawings is to be assigned to Telstra
Telst
ra W
ireles
s Ope
ratio
ns T
empla
te - 0
1786
6P02
issu
ed F
eb 20
09
MOBILE NETWORK SITE 284142SOUTH PAGET
Q110590 S3-1INDEX
ANTENNA CONFIGURATION TABLE55 DOZER DRIVE, PAGET, QLD 4740
ANTENNANo
ANTENNA TYPE &SIZE H x W x D
ANTENNAHEIGHT
C/L A.G.L.
ANTENNASTATUS
SECTOR NO.& SYSTEM
PHYSICALANTENNABEARING (°T)
A1 31.40m 80°PROPOSED
S1: WCDMA850S1: WCDMA850
S1: LTE1800S1: LTE1800
S1: LTE1800S1: LTE1800ARGUS CVVPX310B2 PANEL
2494 x 353 x 209
A2 31.40m 200°PROPOSED
S2: WCDMA850S2: WCDMA850
S2: LTE1800S2: LTE1800
S2: LTE1800S2: LTE1800ARGUS CVVPX310B2 PANEL
2494 x 353 x 209
A3 31.40m 320°PROPOSED
S3: WCDMA850S3: WCDMA850
S3: LTE1800S3: LTE1800
S3: LTE1800S3: LTE1800ARGUS CVVPX310B2 PANEL
2494 x 353 x 209
A4 31.40m 80°FUTURE
--
--
--ARGUS CVVPX310B2 PANEL
2494 x 353 x 209
A5 31.40m 200°FUTUREARGUS CVVPX310B2 PANEL2494 x 353 x 209
A6 31.40m 320°FUTUREARGUS CVVPX310B2 PANEL2494 x 353 x 209
A7 31.40m 80°FUTUREARGUS CVVPX310B2 PANEL2494 x 353 x 209
A8 31.40m 200°FUTUREARGUS CVVPX310B2 PANEL2494 x 353 x 209
A9 31.40m 320°FUTUREARGUS CVVPX310B2 PANEL2494 x 353 x 209
A10 31.40m 80°--
--
FUTUREARGUS VVPX310B1 PANEL1328 x 290 x 103
A11 31.40m 200°FUTUREARGUS VVPX310B1 PANEL1328 x 290 x 103
A12 31.40m 320°FUTUREARGUS VVPX310B1 PANEL1328 x 290 x 103
NOTE: THIS DRAWING TO BE READ IN CONJUNCTION WITH SHEET S3
NOTE: COMBINED AT 80W RU IN PROPOSED RBS6202*
*
*
*
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--