2424 Evaporative Light Scattering Detector · analyte’s optical properties Waters 2424 ELS...

4
2424 Evaporative Light Scattering Detector Putting confidence in your detection strategy Benefits of adding ELS detection Orthogonal detection technique Detection of analytes without UV/Vis chromophore and/or do not ionize well in MS Nanogram-level detection limits Mass response independent of analyte’s optical properties Waters 2424 ELS Detector. The 2424 ELS Detector allows you to reproducibly detect semi-volatile components as demonstrated by this chromatographic test mix of semi-volatile and non-volatile components. Excellent detection is achieved across the range of components without interference from the DMSO sample diluent. Caffeine Naphazoline Oxymetazoline Oxybutynin Nabumetone LSU 50.00 100.00 150.00 200.00 250.00 300.00 350.00 400.00 450.00 500.00 550.00 600.00 Minutes 0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00 ACHIEVE RICHER ANALYSIS The Waters ® 2424 Evaporative Light Scattering (ELS) Detector, with its compact and innovative design, offers near universal detection of non- volatile and semi-volatile sample components. The 2424 ELS Detector is compatible with both isocratic and gradient separations and has nebulizer options to cover a wide range of analytical and microbore flow rates. By adding the orthogonality of ELS to your detection strategy, you increase peak detection confidence across a wide application space. The 2424 ELS Detector can be used as part of an Alliance ® HPLC or LC/MS system under the control of either Empower ® or MassLynx ® software, or can be operated as a stand-alone detector. Quantification for your entire sample Finding the right balance in a detector designed for evaporative light scattering detection can be the difference between good sensitivity of semi-volatile components and high peak dispersion. The 2424 ELS Detector was designed with this critical balance in mind and delivers reproducible quantification for semi-volatile components without adding high dispersion to fast LC separations. Sample components that elute in the column void volume can be difficult to detect with many techniques, creating an issue of particular concern for strong UV absorbing diluents such as DMSO. The desolvation characteristics of the 2424 ELS Detector can remove the sample diluent interference to give visibility to unretained components in your sample.

Transcript of 2424 Evaporative Light Scattering Detector · analyte’s optical properties Waters 2424 ELS...

  • 2424 Evaporative Light Scattering DetectorPutting confidence in your detection strategy

    Benefits of adding ELS detection ■■ Orthogonal detection

    technique

    ■■ Detection of analytes

    without UV/Vis

    chromophore and/or do

    not ionize well in MS

    ■■ Nanogram-level

    detection limits

    ■■ Mass response

    independent of

    analyte’s optical

    properties

    Waters 2424 ELS Detector.

    The 2424 ELS Detector allows you to reproducibly detect semi-volatile components as demonstrated by this chromatographic test mix of semi-volatile and non-volatile components. Excellent detection is achieved across the range of components without interference from the DMSO sample diluent.

    Caffe

    ine

    Naph

    azol

    ine

    Oxy

    met

    azol

    ine

    Oxy

    buty

    nin

    Nabu

    met

    one

    LSU

    50.00

    100.00

    150.00

    200.00

    250.00

    300.00

    350.00

    400.00

    450.00

    500.00

    550.00

    600.00

    Minutes0.00 0.50 1.00 1.50 2.00 2.50 3.00 3.50 4.00

    ACHIEV E RICHER ANALYSIS

    The Waters® 2424 Evaporative Light Scattering (ELS) Detector, with its

    compact and innovative design, offers near universal detection of non-

    volatile and semi-volatile sample components. The 2424 ELS Detector is

    compatible with both isocratic and gradient separations and has nebulizer

    options to cover a wide range of analytical and microbore flow rates. By adding

    the orthogonality of ELS to your detection strategy, you increase peak detection

    confidence across a wide application space. The 2424 ELS Detector can be

    used as part of an Alliance® HPLC or LC/MS system under the control of either

    Empower® or MassLynx® software, or can be operated as a stand-alone detector.

    Quantification for your entire sample

    Finding the right balance in a detector designed for evaporative light scattering

    detection can be the difference between good sensitivity of semi-volatile

    components and high peak dispersion. The 2424 ELS Detector was designed

    with this critical balance in mind and delivers reproducible quantification for

    semi-volatile components without adding high dispersion to fast LC separations.

    Sample components that elute in the column void volume can be difficult to

    detect with many techniques, creating an issue of particular concern for strong

    UV absorbing diluents such as DMSO. The desolvation characteristics of the

    2424 ELS Detector can remove the sample diluent interference to give visibility

    to unretained components in your sample.

  • AP PLICAT ION SOLUT IONS FOR T HE LABORATORY

    Laboratories around the world rely on the proven performance

    of Waters ELS detectors for superior results across a vast range

    of applications, including the analysis of carbohydrates, fatty

    acids, lipids, surfactants, and pharmaceuticals.

    Complex applications with gradient analysis

    Whether trying to monitor a complex process such as the

    consistent production of food oils or verifying their authenticity

    to prevent adulteration, the use of gradient analysis is

    important for providing a wider separation range of your

    samples. The 2424 ELS Detector is entirely compatible with

    gradient analysis, and with significantly reduced stabilization

    times as compared to other ELS detectors, you can get

    consistent answers, faster.

    Enhance your existing detection capabilities

    For applications where not all components have a UV

    chromophore, adding ELS detection expands the visibility

    of your sample by providing a complementary

    detection capability.

    LSU

    0.00

    200.00

    400.00

    600.00

    800.00

    1000.00

    1200.00

    1400.00

    LSU

    0.00

    200.00

    400.00

    600.00

    800.00

    1000.00

    1200.00

    1400.00

    Minutes0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00

    Molasses

    Food sugar standard1 2 3

    45

    12

    31. p-Toluamide 2. Fructose 3. Glucose4. Sucrose 5. Maltose 6. Lactose

    The gradient analysis of triglycerides in edible oils, overlay of safflower oil (blue) and olive oil (green).

    LSU

    Minutes

    600.00

    500.00

    400.00

    300.00

    200.00

    100.00

    0.00

    8.00

    700.00

    800.00

    900.00

    1000.00

    9.00 10.00 11.00 12.00 13.00 14.00 15.00 17.0016.00

    0.16

    0.12

    0.08

    0.04

    0.00

    -0.04

    -0.08

    Minutes

    PDA

    ELS

    Ace

    sulfa

    me-

    KA

    cesu

    lfam

    e-K

    Sacc

    harin

    Sacc

    harin

    Cycl

    amat

    e

    Sucr

    alos

    e

    Asp

    arta

    ne

    Neoh

    espe

    ridin

    Asp

    arta

    me

    Neoh

    espe

    ridin

    12.00

    10.00

    8.00

    6.00

    4.00

    2.00

    0.000.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00

    AU

    LSU

    While some artificial sweeteners can be analyzed by UV, several lack UV chromophores. In this example, all these artificial sweeteners can be quantified by adding ELS detection.

    Simple food sugars lack a UV chromophore, but they are easily detected and quantified in complex matrices using the 2424 ELS Detector.

  • ALL T HIS T ECHNOLOGY, WIT HOUT ALL T HE BENCHSPAC E

    The 2424 ELS Detector hosts a multitude of innovative design features for detection of your non-UV samples, but with

    simple integration into your system and your laboratory environment.

    Designed for your laboratory■■ Compact footprint for system stacking and reduced

    laboratory space requirement

    ■■ Front-mounted, user-installable lamp

    ■■ Easily accessible nebulizers covering wide flow rate range

    ■■ Open access ready with accelerated nebulizer stabilization

    Maximize your method performance■■ Sampling rates up to 80 points/sec

    ■■ Independent optimization of digital filtering

    ■■ Active nebulizer heating and cooling

    ■■ Auto-optimize gain function

    ■■ Optional external column heater control

    Detection technology■ Reference energy monitoring for consistent long-term signal■ 60° scatter angle detection to minimize stray light and optics polarization

    for long-term optimal sensitivity■ Normalized energy output for improved bench-to-bench repeatability

    Nebulization technology■ Concentric flow nebulizer designed

    for consistent droplet formation■ Heating for method optimization■ Cooling for rapid stabilization

    Desolvation technology■ Temperature controlled and

    monitored to provide optimal conditions for desolvating semi-volatile components

    ■ Optimized geometry for analytical HPLC peak volumes and flow rates

    ■ Desolvation of interfering sample diluent peaks to expose unretained sample components

  • Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 2000 F: 1 508 872 1990 www.waters.com

    Waters, Empower, MassLynx, and Alliance are registered trademarks of Waters Corporation. SystemsQT and T he Science of What’s Possible are trademarks of Waters Corporation. All other trademarks are the property of their respective owners.

    ©2013 Waters Corporation. Printed in the U.S.A.February 2013 720004525EN TC-PC

    COMPLET E T HE CHROMATOGRAPHIC P ICTURE AND BUILD HIGHER CONFIDENC E IN YOUR RESULT S

    Pair a 2424 ELS Detector with a Waters 2489 UV/Vis Detector and SQ Detector 2

    single quadrupole mass detector, and achieve the capability to:

    ■■ Derive more complete peak information in one chromatographic run,

    ■■ Detect molecules that lack a UV/Vis chromophore, complementing absorbance

    detector information, and

    ■■ Analyze compounds that don’t ionize well by MS.

    Supported in both Empower and Masslynx software, you can select the right

    chromatographic data system for your laboratory’s needs. The 2424 ELS Detector

    is also compliance-ready as part of the Alliance HPLC family of systems supported

    within the Systems Qualification Tool (SystemsQT™) technology.

    Alliance HPLC System with 2424 ELS Detector, 2998 PDA Detector, and SQ Detector 2.

    BE ASSURED

    CHOOSE WATERS GLOBAL SERVICES

    Waters Global Services focuses

    on optimizing Waters products

    with superior service, support,

    upgrades, training, and Waters

    Quality Parts®. For more

    information, go to

    waters.com/services