24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test...

11
Dimension tables 98 6 98 6 320 364 243 287 211 320 243 135 100 20 189 291 318 238 100 20 291 339 318 391 16 Systems modules box Metal casing 32 Systems modules box Metal casing WITH SUPPORTS POSITIONED HORIZONTALLY GW 24 606 With hollow lid GW 24 616 With stainless steel lid GW 24 607 With hollow lid GW 24 617 With stainless steel lid GW 24 621 GW 24 622 UNDERFLOOR OUTLET BOXES (16 AND 32 SYSTEM MODULES) TECHNICAL CHARACTERISTICS Standard: EN 60670-1, EN 60670-23 Degree of protection: IP52 between the edge of the underfloor box and the floor IP40 between the lid and the interior of the box (excluding the exit point of the cables) IP20 in the point of exit of the cables Installation temperature: Max +45°C; Min -5°C Material: GW PLAST technopolymer, halogen-free in accordance with EN 60754-2 Point load resistance: 500N Distributed load resistance: 1000N Resistance to abnormal heat and fire: Glow wire test 850°C Compatibility with wiring devices: SYSTEM range 1 Technical Information Version 2.0 For technical information contact the Technical Assistance Service or visit gewiss.com 24 SC

Transcript of 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test...

Page 1: 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test 850°C ... GW 48 006 PM GW 48 126 PM ... resistance Limited resistance 48 PT DIN

Dimension tables

98

6

98

6

320

364

243

287

211

320

243

135

100

20

189

291

318

238

100

20

291

339

318

391

16 Systems modules box Metal casing

32 Systems modules box Metal casing

WITH SUPPORTS POSITIONED HORIZONTALLY

GW 24 606With hollow lid

GW 24 616With stainless steel lid

GW 24 607With hollow lid

GW 24 617With stainless steel lid

GW 24 621

GW 24 622

UNDERFLOOR OUTLET BOXES (16 AND 32 SYSTEM MODULES)

TECHNICAL CHARACTERISTICS

Standard: EN 60670-1, EN 60670-23Degree of protection: IP52 between the edge of the underfloor box and the floor IP40 between the lid and the interior of the box (excluding the exit point of the cables) IP20 in the point of exit of the cablesInstallation temperature: Max +45°C; Min -5°C

Material: GW PLAST technopolymer, halogen-free in accordance with EN 60754-2Point load resistance: 500NDistributed load resistance: 1000N Resistance to abnormal heat and fire: Glow wire test 850°CCompatibility with wiring devices: SYSTEM range

1Technical Information Version 2.0

For technical information contact the Technical Assistance Service or visit gewiss.com

24 SC

Page 2: 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test 850°C ... GW 48 006 PM GW 48 126 PM ... resistance Limited resistance 48 PT DIN

Dimension tables

WITH SUPPORTS POSITIONED VERTICALLY

98

6

98

6

320

364

243

287

211

320

243

135

100

20

189

291

318

238

100

20

291

339

318

391

10 Systems modules box Metal casing

20 Systems modules box Metal casing

GW 24 601With hollow lid

GW 24 611With stainless steel lid

GW 24 602With hollow lid

GW 24 612With stainless steel lid

GW 24 621

GW 24 622

UNDERFLOOR OUTLET BOXES (10 AND 20 SYSTEM MODULES)

TECHNICAL CHARACTERISTICS

Standard: EN 60670-1, EN 60670-23 Degree of protection: IP52 between the edge of the underfloor box and the floor IP40 between the lid and the interior of the box (excluding the exit point of the cables) IP20 in the point of exit of the cablesInstallation temperature: Max +45°C; Min -5°C

Material: GW PLAST technopolymer, halogen-free in accordance with EN 60754-2Point load resistance: 500NDistributed load resistance: 1000N Resistance to abnormal heat and fire: Glow wire test 850°CCompatibility with wiring devices: SYSTEM range

Technical Information Version 2.02

For technical information contact the Technical Assistance Service or visit gewiss.com

24 SC

Page 3: 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test 850°C ... GW 48 006 PM GW 48 126 PM ... resistance Limited resistance 48 PT DIN

BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS

Saline solution

Acids Bases Solvents Mineral oil

UV raysConcentrated Diluted Concentrated Diluted Hexane Benzol Acetone Ethyl alcohol

ResistantNot

resistantNot

resistantLimited

resistanceLimited

resistanceNot

resistantNot

resistantNot

resistantLimited

resistanceLimited

resistanceLimited

resistance

Dimension tables

6 gangGW 24 206

ROUNDGW 24 232

SQUAREGW 24 231

3 gang GW 24 4034 gang GW 24 404

6 gangGW 24 406

12 gangGW 24 238

8 gangGW 24 237

18 gangGW 24 239

GW 24 403 GW 24 404 GW 24 406

Code 3 gang BIG BOX 4 gang BIG BOX 6 gang BIG BOX

A 96 121 171

B 58 58 60

C 119 144 194

D 80 85 90

E 49 49 49

F 50,5 50,5 50,5

G 83,5 108,5 100

FLUSH-MOUNTING BOXES

FLUSH-MOUNTING BOXES FOR MASONRY WALLS

Standard: IEC 60670-1; EN 60670-1;Degree of protection: IP40Installation temperature: max. +60°C; min. -15°CMaterial: GW PLAST technopolymer, halogen-free in accordance with EN 60754-2

Impact resistance: IK 07 (referred to wall-mounting boxes and lids)Heat resistance: thermo-pressure with ball 70°CResistance to abnormal heat and fire: Glow wire test 650°CInstallation: for masonry walls

TECHNICAL CHARACTERISTICS

3Technical Information Version 2.0

For technical information contact the Technical Assistance Service or visit gewiss.com

24 SC

Page 4: 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test 850°C ... GW 48 006 PM GW 48 126 PM ... resistance Limited resistance 48 PT DIN

238

306 80

306

396

85

GW 24 101

GW 24 102

FLUSH-MOUNTING BOXES

Technical Information Version 2.04

For technical information contact the Technical Assistance Service or visit gewiss.com

24 SC

Page 5: 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test 850°C ... GW 48 006 PM GW 48 126 PM ... resistance Limited resistance 48 PT DIN

PLAYBUS WALL-MOUNTING BOXES

CodeGW 32 431GW 32 432

GW 32 436GW 32 437

3 GANG 4+4 GANG

A 80 140

B 116 140.6

C 83.5 108.5

D 90 78

E 50 110

F - 57.5

G 50 53

GW 32 431 - GW 32 432GW 32 436 - GW 32 437

COMPACT WALL-MOUNTING BOXES

DEEP LIDS

BLANK PLATES

CodeGW 24 211GW 24 212

GW 24 213GW 24 214

GW 24 215GW 24 216

3 GANG 4 GANG 3+3 GANG

B 83.5 108.5 83.5

C 110 134 110

D 80 80 133

E - - 51

Code GW 24 006 GW 24 007

3 GANG 3+3 GANG

A 83 136

B 83.5 83.5

C 113 113

D 96 96

E 65 119

F – 51

GW 24 006GW 24 007

TOP SYSTEM WALL-MOUNTING BOXES

GW 24 227GW 24 228

GW 22 471 GW 22 472

GW 24 215 - GW 24 216GW 24 211 - GW 24 212GW 24 213 - GW 24 214

Screw tightening torque: 0.8 Nm

Screw tightening torque: 0.8 Nm

Screw tightening torque: 0.8 Nm

5Technical Information Version 2.0

For technical information contact the Technical Assistance Service or visit gewiss.com

24 SC

Page 6: 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test 850°C ... GW 48 006 PM GW 48 126 PM ... resistance Limited resistance 48 PT DIN

1600

mm

Fixing on a metal frame

Articles On metal frame On sheet On masonry wall

Enclosures and distribution boards

- Junction boxes- Boxes for interlocked socket-outlets 67IB and 44IB

(with tabs*)

- Boxes for domestic ranges - 3/4/6 gangs- Boxes for round domestic ranges - 2 and 2+2 gangs (with clamps)

Box for domestic ranges - 8 gangs (4+4) **(with tabs*)

Box for Master ICE(with tabs*)

* Tabs on the sides of the horizontal walls. Boards (24, 36, 54, 72 modules) and box for interlocked socket-outlets (67 IB) equipped with fixing tabs on the sides of the vertical walls. ** Can also be used for the installation of command panels and video entryphones.

The products can be fixed on a metal frame in two ways: for products with tabs on the sides of the horizontal walls, use an extra horizontal frame; for products with tabs on the sides of the vertical walls, use vertical uprights. The structure is created with the aid of special screws for use with plasterboard, then the back-mounting box is fixed to the frame by means of the tabs.

E.g. assembly on a “U” rail profile (12 M enclosure)

Assembly of back-mounting box with tabs on the sides of

the horizontal walls

Assembly of back-mounting box with tabs on the sides of

the vertical walls

E.g. assembly on a “C” upright profile (24 M board)

FIXING METHODS FOR GREEN WALL PRODUCTS

Technical Information Version 2.06

For technical information contact the Technical Assistance Service or visit gewiss.com

24 SC

Page 7: 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test 850°C ... GW 48 006 PM GW 48 126 PM ... resistance Limited resistance 48 PT DIN

ø68 mm

Fixing on plasterboard

Fixing on a masonry wall

Method A: with tabs The back-mounting box is fixed to the back of the sheet with the aid of the tabs, then anchored from the front of the sheet with special screws for use with plasterboard.

The back-mounting boxes of the PT DIN GREEN WALL and CM GREEN WALL junction boxes and of the boxes for interlocked switched socket-outlets are equipped with special reference points so they can be fixed to masonry walls with the aid of wall plugs.

Method B: with clampsThe boxes for modular domestic ranges (3,4,6 gangs) and the round boxes can be fixed directly to walls (even double sheet walls) using the metal clamps. To prepare the sheet for the installation of the boxes, use a hollow mill ø 68 (for rectangular boxes of 3,4,6 gangs) or a hollow mill ø 68 (for round boxes), using the references on the boxes themselves.

E.g. fixing of a 3-gang box

E.g. fixing of a junction box

E.g. fixing of a junction box

7Technical Information Version 2.0

For technical information contact the Technical Assistance Service or visit gewiss.com

24 SC

Page 8: 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test 850°C ... GW 48 006 PM GW 48 126 PM ... resistance Limited resistance 48 PT DIN

E

DA

G

N° - S

N° / M N° / P

M

N

' D /

' E

7.5H

CF

B

' L' I

LI

Dimension tables

JUNCTION BOXES

Notes: H-type casing in compliance with EN60670-22, and Ha-type in compliance with IEC60670-22.

Regulation: EN 60670-1; EN 60670-22; IEC 60670-24Degree of protection: IP 40Installation temperature: max. +60°C; min. -15°CMaterial: GW PLAST technopolymer, halogen-free in accordance with EN 60754-2

Impact resistance: IK 07 (referred to the lids)Heat resistance: thermo-pressure with ball 70°CResistance to abnormal heat and fire: Glow wire test 850°CInstallation: for mobile and plasterboard walls

Code

Modular boxes Cover Deep lid Max Ø of conduit

per sector

Max Ø of conduit in the back-

mounting box

Pde max. power

lossA B C G H N° / P No. / SMAX

no./MI L ’I ’L D E F ’D ’E M N

GW 48 006 PMGW 48 126 PMGW 48 086

196 152 75 207 57 1/100 2 4.5 69 61 62 53.5 222 178 79 214 170 49 56 Ø50 Ø32 11W

GW 48 007 PMGW 47 087

294 152 75 207 57 1/208 3 5 69 61 62 53.5 320 178 79 312 170 66 73 Ø50 Ø32 13W

GW 48 008 PMGW 48 088

392 152 75 207 57 2/153 4 5 70 63 63 55.5 418 178 80 410 170 66 73 Ø50 Ø32 17W

GW 48 009 PM 480 160 75 213 571/1531/250

3 8 70 61 63 53.5 506 186 80.5 - - - - Ø50 Ø50 25W

BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS

AgentSaline

solution

Acids Bases Solvents Mineral oil

UV raysConcentrated Diluted Concentrated Diluted Hexane Benzol Acetone Ethyl alcohol

48 PT / PT DIN standard

coverResistant

Not resistant

Not resistant

Limited resistance

Limited resistance

Not resistant

Not resistant

Not resistant

Limited resistance

Limited resistance

Limited resistance

Shockproof cover for 48 PT / PT DIN

ResistantNot

resistantLimited

resistanceNot

resistantLimited

resistanceResistant

Not resistant

Not resistant

Limited resistance

Limited resistance

Limited resistance

48 PT DIN GREEN WALL - JUNCTION, CONNECTION AND DOMOTIC BOX - IP40

TECHNICAL CHARACTERISTICS

Technical Information Version 2.08

For technical information contact the Technical Assistance Service or visit gewiss.com

24 SC

Page 9: 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test 850°C ... GW 48 006 PM GW 48 126 PM ... resistance Limited resistance 48 PT DIN

Notes: H-type casing in compliance with EN60670-1, and Ha-type in compliance with IEC 60670-1.

Regulation: IEC 60670-1; EN 60670-1Degree of protection: IP 40Installation temperature: max. +60°C, min. -15°C (min. -25°C for boxes with 3,4,6 gangs)Material: GW PLAST technopolymer, halogen-free in accordance with EN 60754-2

Heat resistance: thermo-pressure with ball 70°CResistance to abnormal heat and fire: Glow wire test 850°CInstallation: for mobile and plasterboard walls

73

133.5 50

73

110 50

73

180 50

11256

ø20ø20ø20ø16ø25 ø25

ø32

ø20 ø20 ø20ø16 ø25ø25

ø68ø32

136.3

177

133.

5

57

Dimension tables

BOXES FOR MODULAR RANGES, KNX DEVICES AND DIGITAL VISION

3 gangs GW 24 403 PM

6 gangs GW 24 406 PM 8 gangs (4+4) GW 24 237 PM

4 gangs GW 24 404 PM

BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS

Saline solution

Acids Bases Solvents Mineral oil

UV raysConcentrated Diluted Concentrated Diluted Hexane Benzol Acetone Ethyl alcohol

Boxes with 3, 4 and

6 gangs Resistant

Not resistant

Not resistant

Limited resistance

Limited resistance

Not resistant

Not resistant

Not resistant

Limited resistance

Limited resistance

Limited resistance

Round boxes Resistant

Not resistant

Not resistant

Limited resistance

Limited resistance

Not resistant

Not resistant

Not resistant

Limited resistance

Limited resistance

Limited resistance

Boxes (with fixing

tabs)Resistant

Not resistant

Not resistant

Limited resistance

Limited resistance

Not resistant

Not resistant

Not resistant

Limited resistance

Limited resistance

Limited resistance

24 SC GREEN WALL - FOR WIRING DEVICES AND HOME&BUILDING AUTOMATION DEVICES

TECHNICAL CHARACTERISTICS

73

133.5 50

73

110 50

73

180 50

11256

ø20ø20ø20ø16ø25 ø25

ø32

ø20 ø20 ø20ø16 ø25ø25

ø68ø32

136.3

177

133.

5

57

9Technical Information Version 2.0

For technical information contact the Technical Assistance Service or visit gewiss.com

24 SC

Page 10: 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test 850°C ... GW 48 006 PM GW 48 126 PM ... resistance Limited resistance 48 PT DIN

Dimension tables

BOXES FOR WIRING DEVICES AND HOME&BUILDING AUTOMATION DEVICES

GW 24 101 PM

GW 24 234 PMø7

2

45

ø65

GW 24 282 PM

72

125.5 45

24 SC GREEN WALL - FOR WIRING DEVICES AND HOME&BUILDING AUTOMATION DEVICES

238

306 80

258

350

396

306 85

306182

80

281.

523

8

GW 24 102 PM

Technical Information Version 2.010

For technical information contact the Technical Assistance Service or visit gewiss.com

24 SC

Page 11: 24 SCpro.gewiss.com/irj/go/km/docs/FILE/ZIT/CT_SERIE 24 SC... ·  · 2017-10-19... Glow wire test 850°C ... GW 48 006 PM GW 48 126 PM ... resistance Limited resistance 48 PT DIN

INSTALLATION TYPE VERSIONS CHARACTERISTICS / PERFORMANCE

Flus

h-m

ount

ing

ROUND BOXESModular, Conical, Cylindrical Ø 65 and Cylindrical Ø 85

A complete range suitable for every type of installation.

SQUARE BOXES ModularPossibility of combined composition without the help of accessories.

RECTANGULAR BIG BOXES

3, 4 and 6 gang6 (3+3), 8 (4+4), 12 (6+6) and 18 (6+6+6) gang

Increased internal space for wiring. Possibility of internal circuit separation.

BOXES FOR TELEPHONE SYSTEMS

Conventional and for prefabricated versions Fitted for conduit inlet Ø 20

Flus

h-m

ount

ing

for

plas

terb

oard

s wal

ls ROUND BOXES Cylindrical Ø 65

RECTANGULAR BOXES 3, 4 and 6 gang

Inte

rfac

e fo

r flu

sh- a

nd su

rfac

e-m

ount

ing

COVER WITH WINDOW Universal for 1 and 3 gang plates

They allow you to switch from a chased system to an exposed one with trunking.Excellent design quality of the installation.

BLANK COVER

Surf

ace-

mou

ntin

g

FOR CHORUS RANGE 3 and 4 gang in two colors (White and Black) Suitable for ONE plates

FOR CHORUS RANGE 2 and 2+2 gang horizontal and vertical in two colors (White and Black)

Suitable for ONE INTERNATIONAL plates

FOR PLAYBUS RANGE3 gangs and 4 + 4 gang, in two colours (Cloud white and Toner black)

Suitable for PLAYBUS plates.Pre-arrangement for conduit or trunking inlet.

FOR SYSTEM RANGE 3 and 4 gang in Cloud whiteSuitable for TOP SYSTEM plates.Pre-arrangement for conduit or trunking inlet.

11Technical Information Version 2.0

For technical information contact the Technical Assistance Service or visit gewiss.com

24 SC