24 Flush Mount DeFlector Vent: sKMD24F0As · 2018. 9. 13. · E 2 Shelf detail showing the...

4
E 1 C N H E F D A B J L I M K G Note: the face of the shelf must sit 1 3 /4" (44.45 mm) back from the face of the cabinet. cabinet face shelf face O 24" FLUSH MOUNT DEFLECTOR VENT: SKMD24F0AS INSTALLATION INSTRUCTIONS 1. Prepare cabinet opening as shown in Figures 1, 2A, 2B, 2C. C L Top view A Anti-Tip block Mounting cleat B C Drawer face Cabinet face Note: the mounting surface of the finished cleat must sit 1 1 /16" (26.97 mm) back from the face of the cabinet [pushing the face of the drawer out 1 /4" (6.35 mm)]. Figure 1 Figure 2A IMPORTANT NOTES TO THE INSTALLER Read all of the Installation Manual that is included with the Microwave Drawer before installing in the flush mount configuration. Observe all governing codes, ordinances, and safety instructions. Be sure to leave these instructions with the consumer. Parts includes: Qty. Part number 1 PREF-B019MRP0 Flush Mount Deflector Vent 2 LX-CZB055MRE0 Mounting screws TINSEB541MRR2 A. 6" (152.40 mm) B. Suggested electrical outlet location C. Anti-Tip block D. 5" (127 mm) E. 3-1/2" (88.90 mm) F. 4" (101.60 mm) G. 24-3/16" (614.35 mm) minimum 24-1/2" (622.3 mm) maximum H. 14-13/16" (376.24 mm) to bottom of Anti-Tip block I. 1-1/16" (26.97 mm) J. 23-1/2" (596.90 mm) minimum depth K. 22-1/8" (561.97 mm) L. 1-3/4" (44.45 mm) M. 16-7/8" (428.62 mm) opening N. Floor must support 100 lb (45.4 kg) O. 1-3/4" (44.45 mm) A. 22" (558.8 mm) mounting cleat opening width B. 1/4" (6.35 mm) C. 1-1/16" (26.97 mm)

Transcript of 24 Flush Mount DeFlector Vent: sKMD24F0As · 2018. 9. 13. · E 2 Shelf detail showing the...

Page 1: 24 Flush Mount DeFlector Vent: sKMD24F0As · 2018. 9. 13. · E 2 Shelf detail showing the deflector vent installed. Shelf detail showing the deflector vent during installation. Position

E 1

C

N

H

E

F

D

AB

J L

I

M

K

G

Note: the face of the shelf must sit 1 3/4" (44.45 mm) back from

the face of the cabinet.

cabinet face

shelf face O

24" Flush Mount DeFlector Vent: sKMD24F0As INSTALLATION INSTRUCTIONS

1. Prepare cabinet opening as shown in Figures 1, 2A, 2B, 2C.

CLTop view

A

Anti-Tip block

Mounting cleat

B CDrawer faceCabinet

face

Note: the mounting surface of the finished cleat must sit 1 1/16" (26.97 mm) backfrom the face of the cabinet [pushing the face of the drawer out 1/4" (6.35 mm)].

Figure 1

Figure 2A

Important notes to the Installer • Read all of the Installation Manual that is included with

the Microwave Drawer before installing in the flush mount configuration.

• Observe all governing codes, ordinances, and safety instructions.

•Be sure to leave these instructions with the consumer.

Parts includes:

Qty. Part number

1

PREF-B019MRP0 Flush Mount Deflector Vent

2 LX-CZB055MRE0 Mounting screws

T INSEB541MRR2

A. 6" (152.40 mm)B. Suggested electrical outlet locationC. Anti-Tip blockD. 5" (127 mm)E. 3-1/2" (88.90 mm)F. 4" (101.60 mm)G. 24-3/16" (614.35 mm) minimum

24-1/2" (622.3 mm) maximumH. 14-13/16" (376.24 mm) to bottom of

Anti-Tip blockI. 1-1/16" (26.97 mm)J. 23-1/2" (596.90 mm) minimum depthK. 22-1/8" (561.97 mm) L. 1-3/4" (44.45 mm) M. 16-7/8" (428.62 mm) openingN. Floor must support 100 lb (45.4 kg)O. 1-3/4" (44.45 mm)

A. 22" (558.8 mm) mounting cleat opening widthB. 1/4" (6.35 mm)C. 1-1/16" (26.97 mm)

Page 2: 24 Flush Mount DeFlector Vent: sKMD24F0As · 2018. 9. 13. · E 2 Shelf detail showing the deflector vent installed. Shelf detail showing the deflector vent during installation. Position

E 2

Shelf detail showing the deflector vent installed.

Shelf detail showing the deflector vent during installation.Position deflector vent and mark holes. Pre drill using a 1/16" (1.57 mm) bit before mounting.

C

Front view

No oven

B

ASuggested electrical

outlet location Anti-Tip block

3/4" (19.05 mm)shelf

Side view

1 3/4" (44.45 mm)front face of shelf

Front face of cabinet

16 7/8"(428.62 mm)flush opening

height

Move oven locationdownward for extended countertops for better viewing angle. Anti-Tip

block

3. Place the drawer adjacent to the wall or cabinet opening. Plug the power supply cord into the electrical outlet.

4. Carefully guide the drawer into the prepared opening. Avoid contact with the sides of the cutout opening and also pinching the cord between the oven and the wall.

5. Slide the drawer all the way back until the mounting flanges touch the cleats mounted in the cabinet opening.

6. Open the drawer. Using the 4 holes on the drawer as a template, pre drill the cabinet using a 1/16” (1.57 mm) bit. See Figure 4.

Figure 3A

Figure 4

Figure 3B

2. Install deflector as shown in Figure 3A.

7. Secure the drawer with the 4 screws supplied.

Mountingflange

Figure 2B

Figure 2C

A. 22-1/8" (561.97 mm) mounting cleat opening widthB. 24-3/16" (614.35 mm) minimum

24-1/2" (622.3 mm) maximum flush opening width

C. 3/4" (19.05 mm) shelf

Page 3: 24 Flush Mount DeFlector Vent: sKMD24F0As · 2018. 9. 13. · E 2 Shelf detail showing the deflector vent installed. Shelf detail showing the deflector vent during installation. Position

E 3

C

N

H

E

F

D

BA

JL

I

cabinet face

shelf face O

G

KM

Note: the face of the shelf must sit 1 3/4" (44.45 mm) back from

the face of the cabinet.

30" Flush Mount DeFlector Vent: sKMD30F0As INSTALLATION INSTRUCTION

1. Prepare cabinet opening as shown in Figures 1, 2A, 2B, 2C.

CLTop view

A

B C

Anti-Tip block

Mounting cleat

Drawer faceCabinet

face

Note: the mounting surface of the finished cleat must sit 1 1/16" (26.97 mm) backfrom the face of the cabinet [pushing the face of the drawer out 1/4" (6.35 mm)].

Figure 1

Figure 2A

Important notes to the Installer • Read all of the Installation Manual that is included with

the Microwave Drawer before installing in the flush mount configuration.

• Observe all governing codes, ordinances, and safety instructions.

•Be sure to leave these instructions with the consumer.

Parts includes:

Qty. Part number

1

PREF-B020MRP0 Flush Mount Deflector Vent

2 LX-CZB055MRE0 Mounting screws

A. 6" (152.40 mm)B. Suggested electrical outlet locationC. Anti-Tip blockD. 5" (127 mm)E. 3-1/2" (88.90 mm)F. 4" (101.60 mm)G. 30-5/16" (769.92 mm) minimum

30-5/8" (777.87 mm) maximumH. 14-13/16" (376.24 mm) to bottom of

Anti-Tip blockI. 1-1/16" (26.97 mm)J. 23-1/2" (596.90 mm) minimum depthK. 28-7/16" (722.3 mm) L. 1-3/4" (44.45 mm) M. 16-7/8" (428.62 mm) openingN. Floor must support 100 lb (45.4 kg)O. 1-3/4" (44.45 mm)

A. 28-1/2" (723.9 mm) mounting cleat opening widthB. 1/4" (6.35 mm)C. 1-1/16" (26.97 mm)

Page 4: 24 Flush Mount DeFlector Vent: sKMD24F0As · 2018. 9. 13. · E 2 Shelf detail showing the deflector vent installed. Shelf detail showing the deflector vent during installation. Position

E 4

Shelf detail showing the deflector shield installed.

Shelf detail showing the deflector vent during installation.Position deflector vent and mark holes. Pre drill using a 1/16" (1.57 mm) bit before mounting.

Front view

No oven

C

B

ASuggested electrical

outlet location Anti-Tip block

1 Sharp Plaza Suite 1, Mahwah, New Jersey 07495-1123, USA • 1-800-BE-SHARP (237-4277)335 Britannia Road East, Mississauga, Ontario, L4Z 1W9, Canada

3. Place the drawer adjacent to the wall or cabinet opening. Plug the power supply cord into the electrical outlet.

4. Carefully guide the drawer into the prepared opening. Avoid contact with the sides of the cutout opening and also pinching the cord between the oven and the wall.

5. Slide the drawer all the way back until the mounting flanges touch the cleats mounted in the cabinet opening.

6. Open the drawer. Using the 4 holes on the drawer as a template, pre drill the cabinet using a 1/16” (1.57 mm) bit. See Figure 4.

Figure 3A

Figure 4

Figure 3B

2. Install deflector as shown in Figure 3A.

7. Secure the drawer with the 4 screws supplied.

Mountingflange

Figure 2B

Figure 2C

3/4" (19.05 mm)shelf

Side view

1 3/4" (44.45 mm)front face of shelf

Front face of cabinet

16 7/8"(428.62 mm)flush opening

height

Move oven locationdownward for extended countertops for better viewing angle. Anti-Tip

block

A. 28-7/16" (722.3 mm) mounting cleat opening widthB. 30-5/16" (769.92 mm) minimum

30-5/8" (777.87 mm) maximum flush opening width

C. 3/4" (19.05 mm) shelf