2355 Main Street Suite 120, Irvine CA 92614 Arielbath.com | … · 2019-09-17 · 90x90 Ventilater...

10
2355 Main Street Suite 120, Irvine CA 92614 Arielbath.com | Atlasusa.net email: [email protected] | Phone: (800) 827-5950 DZ938F8 Installation Instruction

Transcript of 2355 Main Street Suite 120, Irvine CA 92614 Arielbath.com | … · 2019-09-17 · 90x90 Ventilater...

2355 Main Street Suite 120, Irvine CA 92614Arielbath.com | Atlasusa.netemail: [email protected] | Phone: (800) 827-5950

DZ938F8 Installation Instruction

C o nn e c t io n B l u e p r in t O f S t e a m B ox�

Component Introduction

Water and Wire Connection Dimension

Installation Step

Control Panel Button and Function Demonstrationfor F3 Type Steam House

Steam House Removing Descale Cleaning Function

Troubleshooting

PRINCIPLE OF THE ELECTRIC INSTALLATION CONTENTS

EQUIPMENTS REFERENCE

...................................................1-2

..................................3

............................................................4-12

..............................................13-14

...............15

................................................................16

Connection Blueprint of Steam Box

MAIN CONTROL BOX

GeneratorO3

Control Panel

Mic Temp detectorRadio Antenna

Loudspeaker1

Loudspeaker2

Steam Generator

Rated Voltage

ACC220-240V/50HZ

ACC220-240V/50HZ

ACC220-240V/50HZ

ACC110-120V/60HZ 1125W

3000W

10W

10W

3W

5W

AC240V/60HZ

DC12VDC12V

Pump

Steam Generator

Ventilator

Magnetic Valve

Loud Speaker

Remark

ChromatherapyLamp

Computer ControlPanel

DC12VDC12V

DC12VDC12V

AC240V/60HZ

Rated Voltage Rated PowerParameter

Components

BU BURD GN GY

GY YE

Y.G

Y.G

Drain

WaterInlet

WaterDetector

HeatPartHeatPtotector WH

BK

PowerSupply

SHOCKPROOF: WATERPROOF: 1PX5

V1.0

1 TYPE

L1 L2

GND

Light12V

Fan12V

AB

CD

E F G H

RGB12V

The hole and funtion depend on the machine model, in addition the funtion of the hole can be choosed.Techniques and parameters are subject to change without notice.

1. Product ground wire should be connected to permanent fixed ground wire.

2. It is prohibited to use this product under the influence of alcohol or hypnotic.

3. It is not allowed for children to operate this product without the supervision of adult.

4. Electrical components, except remote control, must be well placed and fixed so that they will never fall into the water.

5. Special Notice: Water temperatures can not exceed 60 degrees centigrade.

6. Do not use strong corrosive detergent (such as vitriol, hydrochloric acid, lye) to disinfect or clean the body of steam shower house.

7. Please read through this manual before usage and operate according to this manual.

8. The pump casing will be hot when motor working. To prevent being burnt by the steam, do not touch motor casing when motor is still running or just being stopped.

9. Before starting motor, please check and make sure the water supply level is over all the jets.

10. Don’t let anything fall into or inserted into the opening of the motor and pump.

11. Don’t modify the pump.12. The diameter of ground wire shall be more than 1.5 square

mm.13. Caution: To prevent wire area has no electric shock, the

ground outlet must be connected to GFCI/RCD (leakage circuit breaker)

14. Caution: To prevent electric shock, do not use extended wire and the supply power socket must be located there.

15. Caution: To prevent being burnt by the steam, do not open the cover of the descale cleaning box during the motor is running.

16. If the power cord is damaged, it must be replaced by the manufacturer or a qualified service engineer to avoid any risks to safety.

17. Keep electrical appliances without supervision.18. Indoor use only.19. Do not dispose of electrical appliances as unsorted

municipal waste, use seperate collection facilities.Contact your local government for informationregarding the collection systems available.If electrical appliances are disposed of in landfillsor dumps, hazardous substances can leak into the groundwater and get into the food chain,damagingyour health and well-being.

20. To protect against the tisk of electrical shock, do not immerse the unit, cor or plug in water or other liquid.

21. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

22. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.

23. This appliance can be used by children aged from 8 years and abover persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

24. The instructions for appliances connected to the water mains shall state.- maximum water inflow pressure:0.75MPa,- maximum water inflow pressure:0.35MPa,

25. The appliance should be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.

SAFETY INFORMATION

COMPONENT INTRODUCTIONSPARE PARTS BAGS:

F Type WaterProof Strip

L011B WaterProof Strip

LS-01*40*260Handle

Waste WithTrap

19 20 21

23 24 25

27 28 29 Right Glass Wall A

Side Panel

Movable Door

Fixed Glass Door 22

26

30

L008A (6MM)Magnetic Strip

D222-1 CopperShower

Right Glass Wall Chrome PlatedFaucet

Lower Track ForDZ938F8

Stainless SteelRoof Fixer

Side Panel B31 32 33

35 36 37

39

Supporting Bar 2 34

38

Roof

Adjustable Leg White Skirt Screw

40 B1 Elastic Wheel41

Upper Track ForDZ938F8

Corner AluminumProfile

Descale CleaningBox

COMPONENT INTRODUCTION

21

6

7

8

39

38

33

32

31

30

28

29

34

35

36

40

41

37

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

1

2

3

4

5

Acrylic LampCover

Middle Panel

F8 Control Panel

Tray Shower Tray SkirtSteam Outlet

Side Panel A

Left Glass Wall A

Left Glass Wall

2063#/C Shower

Copper Jets

4” WaterproofLoud Speaker

ChromatherapyLamp

1/2 Copper Nut Black PlasticSpacer

10 11 12

13 14 15

16 17 18

1 2 3

4 5 6

7 8 9

Shampoo Holder ChromeplatedJets (5 Holes)

90x90 Ventilater

Stainless Steel RoofFixer (13PCS)

4x10 Self-LockingScrews (34PCS)

931-1 SupportingIron Bar (4PCS)

3.5x30 RoundSelf-LockingScrews (8PCS)

4x25 RoundSelf-LockingScrews (12PCS)

Decoration CoverFor Panel (12PCS)

6mm Stainless SteelWasherr (16PCS)

6mm SpringWasher (8PCS)

6x30 HexangularAllen Screw (8PCS)

6mm StainlessSteel Nuts (8PCS)

Screw Sleeve(8PCS)

WATER AND WIRE CONNECTION DIMENSTIONMove the shower tray to the suitable place, adjust the botom of the screw, make it on the level. (As illustrated in Drawing 1)

(Notice: Adjust the height of the foot to make the bathtub on level)

FRONT VIEW

SPECIFICATION: 1500 X 1500 X 2250 MM

TOP VIEW

Drawing 1

3051500140011

00

50

100

Hot Water InletCold Water Inlet

100

410 410

2300

2250

190

80

43

INSTALLATION STEP 1

Adjustable Leg

Wrench

INSTALLATION STEP 2The glass walls (including middle panel, left glass wall A and right glass wall A) should be placed on the tray and connect by 4 x 10 slef-locking screws. (As illustrated in A )

INSTALLATION STEP 3Use 4x25mm self locking screws to connect left and right glass wall with middle panel. Cover the decoration cover for the panel in the panel holes.

4x25 Self-Locking Screw

Drawing 2

Drawing 3

65

4x10 Self-Locking Screw

Right Glass WallLeft Glass Wall

Left Glass Wall A Right Glass Wall B

Middle Panel

Decoration Cover for Board

INSTALLATION STEP 4Use 3.5x30 self-locking screws to connect left and right fixed glass doors with upper and lower track.

INSTALLATION STEP 51. Put the left & right side glass wall separately insert into the aluminum profile groove. Then secure with 4x10

self-locking screws. (As illustrated in A )

Glass Door

Glass Wall

4x10 Self-Locking Screw

Right Glass Wall

Left Glass Wall

Corner Aluminum Profile

Drawing 5

87

Upper Track

Lower Track

Fixed Glass Door 3.5x30 Self-Locking Screws

Drawing 4

Water Proof Stripfor Moveable Door

Water Proof Stripfor Moveable Door

Strip

INSTALLATION STEP 61. Install the whole set glass door on the shower tray and connect them with left & right glass wall by 4 x 25 self-locking screws.

(As illustrated in drawing A )2. Cover the decoration cover for panel in the panel holes (As illustrated in drawing B )

1. When installing the movable door please hang the sliding door on the upper track (As illustrated in A ), and press the lower roller to hook the lower track (As illustrated in drawing B ). Using a small slotted screwdriver to adjust in case the two sliding doors are not entirely closed.

2. Install fixed door water-proof strip C , install magnetic strip D and waterproof E to two moveable doors.3. Install the handle on the movable doors (As illustrated in F )4. Install the slider bar on the glass wall (As illustrated in G ), connect the hand shower hose to the hand shower connector (As

illustrated in H ), then install the shampoo holder (As illustrated in I ).

INSTALLATION STEP 7

Drawing 7

Drawing 6

Hang up themoveabledoor on theupper track

Press thelower wheeland the hookto the lowertrack

Install thehandle on themoveable door

Sliding door installationinstruction chart

109

ShowerConnector

ShowerHose

Glass Clip

Shampoo Holder

4mm PlasticWasher

4x16 RoundAllen Screw

6mm FlatWasher

4mm Nut

4 x 25 self-locking screw

INSTALLATION STEP 81. Connect the glass wall and shower tray by 6x30 hexangular screws. (As illustrated in A )2. Fasten the support iron bar on the panel with 4x10 self-locking screws. (As illustrated in B )3. Put the roof on the glass wall and secure with 4x10 self-locking screws. (As illustrated in C )4. Connect the loudspeaker, chromatherapy lamp, ventilator in accordance with relevant lable plug.

INSTALLATION STEP 7Install ceiling hose, steam hose, steam outlet hose, cold and hot water hose. Finally test whether the electric equipment and fittings run well. (As illustrated in Drawing 9)Note: The Thermostatic faucet is optional.

Fixed Rail

Shower Wall

6x30 Hexangular Screw

6x30 Stainless Steel Nut

6mm Spring Washer

12mm Stainless Steel Washer

6mm Stainless Steel Washer

Screw Sleeve

Shower Tray

GLASS WALL FIXING DRAWING

SupportingIron Bar

Aluminum Panel

Cleaning Joints

Shower Joints

Jet

TemperatureSensor

Radio AntennaVentilatorChromatherapy LampLoud Speaker

a. Fire Wireb. Natural Wirec. Yello Green Ground Wire

Plug

CeilingShower

4x10 Self-LockingScrewChromatherapy Lamp Wire

Ceiling Shower HoseVentilator Wire

Speaker Wire

Drawing 8

Drawing 9 Right SideShower

Left Side Shower

ShowerTray

Right SideShower

ShowerTray

HotWater

CeilingShower

Cold WaterJoints

ColdWater

Shower

STANDARD FAUCET

Right SideShower

Left Side Shower

ShowerTray

Right SideShowerShowerTray

WaterAdjusting

ThermostaticAdjusting

CeilingShower

Cold WaterJoints

Shower

WaterAdjusting

Hot WaterJoints

OPTIONAL FAUCET

1211

4x10 Self-LockingScrew

Stainless steel clipfor fixing cover

1. POWER KEYPress to switch on the strea room, press again toswitch it off. The steam room will shut down in 60minutes automatically. (As in Picture 1)

2. STEAM KEYPress . The steam generator starts working.The temperature will be shown on the control panel likein picture 2. Press while the system is off for 2seconds to start the water draining function, let gothe button to stop the function. Automatic water draining function turnson with the full water level, otherwise the iron is silent. Ambient temperature <=setting temperature-2 two sets of fuse starts to work; ambient temperature> setting temperature the heater stop working.

3. TIME ADJUSTINGWhen the steam function starts to work, press for more than 1 second the setting time will be increased continuously as picture 3. When it reaches to the maximum level and will return to the minimum level automatically. The time setting range is between 5-50 minutes. The defualt setting time is 30 minutes.

4. TEMPERATURE ADJUSTING KEYAfter steam function is turned on, press will increase the temperatures. When press more than 1 second, the setting temperature will be increased continuously until you stop pressing or just when it reaches the maximum limitting temperature that it will return to the minimum limitting temperature automatically.Note: The temperature setting range is between 20ºC-50ºC. The controlled temperature tolerance: ± 3ºC The default temperature is 40ºC. Press for 2 seconds to change the temperature unit before start the steam function.

5. VENTILATOR KEYPress to turn on the ventilator, press again to turn off the ventilator.

6. COLOR LIGHT KEYPress to turn on the color light. After the color light is turned on, each more press will change the different colors of the light. The color light works in this sequence: Turn on, blue --blue--blue and red--red--red and orange--orange--orange and blue--blue--circulating--turn off.Press the key for 2 seconds to turn off the function.

7. LAMP KEYPress the key to turn on the lamp, press againand turn it off. (As picture 6)

8. RADIO KEYPress key to turn on the radio, press again to turn off the radio and turn on the bluetooth; press for the third time to turn off the multimedia. When the bluetooth turns on the icon lighten as pictures 7 and 7-1.The phone icon lightens when answering the call.Press to answer the call and press again to finish.Note: Please connect the mobile phone to the system while using the Bluetooth function.The Bluetooth will disconnect after the system turns off for 10 seconds. It shows bt. F while no Bluetooth connected and bt while the Bluetooth connects well.It shows bt. n when switch to next song, the password is “0000”, The bluetooth name is “SANJUN BT”.

9. CHANNEL MEMORY KEYPress and release within 1 second, the frequency of current channel will be changed; Press and hold it more than 1 second, the frequency of current chanelwill be saved. It can memory total 8 channels.To refuse the call please press key.

10. SELECT KEYThis key gets double functions. When the radio is turned on, this key shows the Frequency function. Press the key and it can be switched from the frequency to the volume function. Press the key, on the Displayer will show like the Picture 10(Volume) or Picture 9(Frequency). Press to adjust volume and switch song while the Bluetooth turns on as picture 9 and 9-1. Picture 9 shows the volume adjustment. 9-1 shows the song switch

F8 CONTROL PANEL KEYS AND OPERATING INSTRUCTIONS F8 CONTROL PANEL KEYS AND OPERATING INSTRUCTIONS

1413

11. VOLUME UP KEYAfter the radio is turned on (As in Picture 9), presswill increase the volume. Hold on the key more than 1 second, volume will keep increasing until the key is released. When (Picture 10) shows on the displayer, press will increase the frequency. Hold on the key more than 1 second, the frequency will keep increasing until the key is released.

12. VOLUME DOWN KEYAfter the radio is turned on, when (Picture 9) is shown on the displayer, press will decrease the volume. Hold on the key more than 1 second, volumed will keep decreasing until the key is released. When (Picture 10) is shown on the displayer, press will decrease the frequency. Hold on the key more than 1 second, the frequency will keep decreasing until the key is released.

1210 11

1

3

8

9

5 7 6

2

4

Picture 10

Picture 1

Picture 2

Picture 3 Picture 6

Picture 7

Picture 8

Picture 9

Picture 7-1

Picture 9-1

Picture 4

Picture 5

Code

E1

E2

E4

E5

E8

E9

Fault

Recognition error

Check whether the line connectionis faulty, or replace the temperature

Check whether the line connectionis faulty, or replace the temperature

Communication error

Water inletovertime

Water inlet failure

Temperature probeis open circuitTemperature probeshort circuit

Please change new main engine

Check whether the communicationconnection is normal, the main engineCheck whether water connectionis normalCheck whether water connectionis normal

Solution

FAULT CODE

STEP 1: POWER OFFFor safety, it is forbidden to twist the cover of detergent box so as to avoid being burnt by the steam. Before using the cleaning function, if it is in an open state, please close all of the function. Press key to power off.

STEP 2: OPEN THE DESCALE COVERAfter confirming the system power off, press the right label and found the detergent box in the steam house. Twist the cover by reverse direction and take out the box cover.

STEP 3: INPUT CLEANING SOLUTIONOpen the detergent box, use the spoon to pour the citric acid or compounds cleaning fluid into the box.

STEP 4: COVER THE DESCALE COVERAfter inputting the cleaning liquid, whirl the box cover in clock wise direction, twist the cover and avoid the steam hurting the people.

STEP 5: POWER ON - RUN THE AUTOMATIC CLEANING FUNCTIONAfter covering the detergent box, press to power on. Then press key to open the cleaning function and let and system to automatically cleaning.

STEP 6: POWER OFF AND WATER DISCHARGEAfter 5 to 10 minutes, press key to close the steam function, and press to power off. The firty water will be discharged automatically. The cleaning process will be finished after 5 minutes.

STEAM HOUSE REMOVING DESCALE CLEANING FUNCTION TROUBLE SHOOTING

ATTENTION:1. It is forbidden to use cleaning function when using other function.2. It is forbidden to use the alkaline compounds to clean the steam generator.3. It is forbidden to use cleaning agent to clean the steam generator, so as to avoid plugging the pipes.WE RECOMMEND THAT YOU USE CITRIC ACID SOLUTION TO CLEAN THE STEAM GENERATOR

Malfunctions Causes Solution

The motor is working normally, but no water comes out from jets or water pressure is not normal

Shaking of bathtub and too noisy

1. The steel stand at the bottom of the bathtub is not balanced.2. The fasten screws for motor and shockproof rubber is incomplete or loose.3. Problem of motor.

1. The suction is partly clogged.2. The water level is too slow (the pressure is not enough).3. The hyrdo-massage water regulating switch is turned off.4. Air exists in air pump water inlet.5. Other.

1. Adjusting the leg to make the steel stand even.2. 4 pieces of screws and 4 shockproof rubbers shall be provided for the motor. Fasten the nuts.3. Contact with your dealer or the manufacturer.

1. Use the screw driver to dismantle the suction and clean it so as to make the water flow smoothly.2. Fill in water until it reaches to normal height, that means the water level is higher than the sensor screws.3. Turn on hyrdro-massage water regulating switch.4. a) Turn on the cleaning function to drive out the air. b) Fasten connecting water inlet parts of water pump to prevent air in.

1. Voltage is abnormal or electric power is disconnected.2. The air pressure switch or micro pneumatic switch is broken.

1. Switch on the power.2. Call an electrician to replace the air pressure switch or pneumatic switch with the same specification.

1. Plug is off.2. Control circuit board is burnt.

1. Re-plug in the plug or replace plug.2. Contact with dealer or manufacture after-sale department.

1. Supply water pressure is low.2. Water inlet block.

1. The waste cover is leakage, the screw is loose or the water divert adjusts too low.2. The pulling cord of water outlet is broken.3. The washer is uneven.

1. Power off or wrong wiring.2. Switched off.3. Wire connection to control box is loose.

1. Temperature limiter or heater is burnt.

1. The circuit of light connection is broken or the lamp seat is loose.2. The light board is broken.

1. Check supply water pressure2. Clean water inle filter.

1. Take off the stopper of pop-up water outlet valve, fasten the screws or adjust the top hole to the proper place.2. Replace with new rubber.3. Dismantel the water outlet, level the washer and re-install it.

1. To provide power supply and do correct wiring.2. Turn on the switch.3. Refasten the wiring connection.

1. Ask professional people to repair.

1. Replace it or re-fasten it.2. Replace.

1. Plug is off.2. Fan blade is blocked.3. Ventilation fan broken.

1. Re-plug in.2. Drive the fan gentley after opening.3. Replace broken ventilator.

The massage motor or the air motor can’t be started

Chromaterapy light doesn’t work

Slow water outlet

The pop-up water outlet valve can’t pop-up or it is leaking

Display panel doesn’t work

Steam key signal on, but no steam comes out

Colorful light doesn’t work

Ventilator doesn’t work

1615