WEBSITE: www.struthers-dunn.com EMAIL: info@ struthers-dunn.com FAX # 1-843-662-8862 PHONE # 1-843-664-3303 PAGE STRUTHERS-DUNN 1 7 8 14 219DXBP (4P-NO + 2P-NC ) LOCKING CLIP 1.468 (37.2) 2.593 (65.5) .435 (11) 3.406 (86.5) .250 (6.35) OPTIONAL MANUAL ACTUATOR 2.625 (66.6) 5 2 3 4 6 7 10 8 9 11 12 219 SERIES industrial plug-in relays offer a vide varity of contact configurations on 12 pin and 14 pin bases. The coil is encapsulated for protection. 219XDXP (4PDT ) 1 7 8 14 219FXXP (6P-NO ) 1 7 8 14 1 12 219ABAP (DPDT + 1NO & 1 NC ) 1 12 219XBXP (DPDT ) WIRING DIAGRAMS BOTTOM VIEW UL Recognized File No. E 13224 1 0.10 Dia. x .435 (2.54 x 11) Typical of all P in Dimensions 2, 4 OR 6 POLE, 10 AMP INDUSTRIAL RELAY 1 12 219BBXP (DPDT + 2 N.O.) 219 SERIES 6 7 6 7 6 7 COIL Pull-in, min. AC Pull-in min. DC Overvoltage, max. CONTACTS Contact Material: TIMING Operate Time: Release Time: DIELECTRIC STRENGTH All Mutually Insulated Points: Insulation : TEMPERATURE Rated Operation: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Operating Position: Weight: 85% of Nominal Voltage 80 % of Nominal Voltage 110% of nominal Voltage Silver Alloy, Gold diffused (Standard) 25 mS Max. @ Nominal Voltage. 20 mS Max. @ Nominal Voltage. 1500 V rms 1/4" over surface, 1/8" thru Air -10 C to +60 C 10 Million Operations no load 100,000 Operations @ Rated Load. Clear polycarbonate. Vertical, Contacts Up 8.5 oz. (241 g) approx. O O UNITS GENERAL SPECIICATIONS (@ 25 C) o

Transcript of 219 SERIES PAGE ONE

Y RELA YS

WE B S IT E : www.s truthers -dunn.c om E MA IL : info@ s truthers -dunn.c om F A X # 1-843-662-8862 P HONE # 1-843-664-3303PAGE STRUTHERS-DUNN

17

8 14

219DXBP(4P-NO + 2P-NC )

LOC K INGC LIP

1.468(37.2)

2.593(65.5)

.435(11)

3.406(86.5)

.250(6.35)

OP T IONAL MANUAL AC T UAT OR

2.625(66.6)

52 3 4 6

710 891112

219 SERIES industrial plug-in relays offer a vide varity of contact configurations on 12 pin and 14 pin bases. The coil is encapsulated for protection.

219XDXP(4PDT )

17

8 14

219FXXP(6P-NO )

17

8 14

1

12

219ABAP(DPDT + 1NO & 1 NC )

1

12

219XBXP(DPDT )

WIR ING DIA G R A MSB OT T OM V IE W

UL R ecognizedF ile No. E 13224

10.10 Dia. x .435 (2.54 x 11)

T ypical of all P in Dimensions

2, 4 OR 6 POLE, 10 AMP INDUSTRIAL RELAY

1

12

219BBXP(DPDT + 2 N.O.)

219SERIES

6

7

6

7

6

7

COIL Pull-in, min. AC Pull-in min. DC Overvoltage, max.CONTACTS Contact Material:

TIMING Operate Time: Release Time:

DIELECTRIC STRENGTH All Mutually Insulated Points: Insulation :

TEMPERATURE Rated Operation:

LIFE EXPECTANCY Mechanical: Electrical:

MISCELLANEOUS Enclosure: Operating Position: Weight:

85% of Nominal Voltage80 % of Nominal Voltage110% of nominal Voltage

Silver Alloy, Gold diffused(Standard)

25 mS Max. @ Nominal Voltage.20 mS Max. @ Nominal Voltage.

1500 V rms1/4" over surface, 1/8" thru Air

-10 C to +60 C

10 Million Operations no load100,000 Operations @ Rated Load.

Clear polycarbonate.Vertical, Contacts Up8.5 oz. (241 g) approx.

O O

UNITS

GENERAL SPECIICATIONS (@ 25 C)o

� �� � � � � ������

WEBSITE: www.struthers-dunn.com EMAIL: [email protected] FAX # 1-843-662-8862 PHONE # 1-843-664-3303 PAGESTRUTHERS-DUNN

219 XBX P L -24DSeries 219 Industrial plug-in styleContact Arrangements XBX (DPDT) ABA (DPDT + 1 Pole-NO & 1 Pole NC) BBX (2 Pole-NO & DPDT) XDX (4 PDT) FXX (6 Pole-NO) DXB (4 Pole-NO & 2 Pole-NC)Standard Features Polycarbonate Cover- CODE "P"

Optional FeaturesIndicator Lamp - CODE "L"Manual Actuator- CODE "M"

Bifurcated Contacts - CODE "33" Perm. Magnet Blowout- CODE "69"

Coil Voltage AC: 6, 12, 24, 120, 240 (Add ) "A" DC: 6, 12, (24-28), 32, 115/125 (Add ) "D"Coil Voltages & Frequencies must be specified.

ORDERING CODETypical Type No.

* Note: Stock 24 Vdc and 115 Vac relays have nameplates stamped 24-28and 115-125 Vdc respectively. These relays operate at 80% of the lowervoltages and operate within allowable temperature rises at higher voltages.250 Vdc - Use 125 Vdc relay and series resistor (6000 �, 5 W) not supplied.

MilliamperesCold Hot

AC RELAYS 50/60 HZ (COIL DATA @ 60HZ Voltage

61224

120240

ResistanceOhms� 10%

1.14.2

15.55402100

15007503757532

Milliamperes Cold Hot

8404102004017

Impedance Ohms

7.227

1202700

13,400

NominalVoltage

NominalVoltage

ResistanceOhms� 10%

15.563.5250375

6200

385189968620

304147776216

612

24 (28)*32

115/125*

10A3A1A3A0.1A

0.5A1.5A150 mA0.5A

24 VDC120 VAC240 VAC28 VDC125 VDC

125 VDC SM125 VDC DM250 VDC SM250 VDC DM

VOLTS MAKE30A30A30A30A30A

30A30A30A30A

10A10A10A10A10A

10A10A10A10A

10A10A5A10A0.5A

1.5A4A0.5A1.5A

RESISTIVE INDUCTIVECARRY

DC RELAYS, 1.8 WATTS (2.5 W @ 125VDC)

BREAK

For versions with suffix "69"Permanent Magnet Blowouts

COIL SPECIFICATIONS @ 25 C

CONTACT RATINGS

MATING SOCKETS27390D - 12 PIN33377D - 14 PIN

STRUTHERS-DUNN

O

219SERIES

2, 4 OR 6 POLE, 10 AMP INDUSTRIAL RELAY

2.593(65.5)

.435(11)

.250(6.35)

3.406(86.5)

LOCKINGCLIP

3.062(77.77)

OPTIONAL MANUAL ACTUATOR

911 10 812

1 652 3 4 7 1.468(37.2)

0.10 Dia. x .435 (2.54 x 11)Typical of all Pin Dimensions

NUCLEAR QUALIFIEDVERSIONS AVAILABLE

1314

219BBXP219XBXP219ABAP

DPDT + 2 NODPDT

DPDT + 1 NO & 1 NC

219XDXP219FXXP219DXBP

4PDT6P-NO

4P-NO + 2P-NC

CONTACTS12 PIN CONTACTS14 PIN

COMMONLY AVAILABLE MODELS

Make before break and other Contact configurations availablelimited only by the number of terminal pins.