PS1800 Centr ifugal Pumping SystemsGeneral Data and Sizing Tables
The curve show the performance range of 4 models at 1800Wpsolar array
- irradiation of 6kWh/m on a tilted surface- ambient temperature 30C
Solar tracking will improve performance by aprox 40%
Application:- drinking water supply- livestock watering- pond management- irrigation
0
10
20
30
40
50
Pump Lift RangeSJ 12-3 2- 12m head
SJ 8-5 2- 25m head
SJ 5-8 2- 40m head
SJ 3-9 20- 50m head
Curve is based onIrradiation 6kWh/m day, tilted surface
Pump ends:
SJ -xx =centrifugal pump
Motor:
brushless DC, maintenance free
LORENTZ offers standard solar pumpsolutions up to 230m (760ft) head and
special solutions up to 750m (2500ft)
head. Ask for charts
met
erhead
SJ12-3
SJ8-5
SJ5-8
SJ3-9
Solar Pumping System / Capacity Diagram6kWh/m/day, 1800Wp solar array
-
7/28/2019 21_3_PS1800 Bomba Solar Sumergible
2/10
Head Metres /Ft.
US
GPD m/day
Direct operated PV-Pump System :
Solar Pump System PS1800 C-SJ3-9
C-SJ3-9
- 1% cable loss
Calculation of system performance is based on:
- non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30C
40/132
35/116
30/100
25 /83
50/165
Wp
900
800
700
600
500
400
300
5
10
15
20
25
30
35
40
45
1000
2000
3000
4000
5000
7000
8000
9000
11000
10000
6000
-
7/28/2019 21_3_PS1800 Bomba Solar Sumergible
3/10
System PerformanceAn irradiation value and the required head in metersare given for a certain solar pumping system.By connecting the point for the power output in Wpof the solar array with an irradiation value, movevertical upwards to the intersection with the requiredhead curve, then horizontal to the left to find thedaily quantity of water that can be pumped ( m/day)Or the other way:
By starting from the daily required water amounthorizontally to the intersection of the required head,then vertically down to the intersection with theexpected solar irradiation, then horizontally to theleft to find the required output of the solar array.
Instantaneous Output
MotorThe LORENTZ submersible motor, type EC1200-C is a 2 pole synchronous brushless DCmotor. Slide ring bearing and ceramic trustbearings are water lubricated.The motor raw earth magnets are hermeticallysealed in stainless steel and encapsulated insynthetic resin.The motor is pressure compensated and thereare no practical depth limitations forsubmergence.No electronics are inside the motor and theentire motor is water filled.
Data:Voltage 3 X 100V electronicall commutated
A B C D Emax BSP
SJ 3A-9 546 186 360 96 98 1 1/4" 11,5 kg
Pump TypeMinimum Internal Diameter
of BoreholeWeight
4" (104mm)
Dimensions [mm]
0,0
0,5
1,0
1,5
2,0
2,5
3,0
3,5
4,0
4,5
5,0
5,5
6,0
200 400 600 800 1000 1200 1400 1600DC Power [W]
flowr
ate[m/h]
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
1400
1500
flowr
ate[
USgal/h]
PS1800 C-SJ3-9 (Item No. 1160 ) for Solar Operation(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)
Instantaneous Output 25 m / 82 ft
35 m / 115 ft
45 m / 148 ft
55 m / 180 ft
50 m / 164 ft
30 m / 98 ft
40 m / 131 ft
Average Values
-
7/28/2019 21_3_PS1800 Bomba Solar Sumergible
4/10
Head Metres /Ft.
US
GPD m/day
Direct operated PV-Pump System :Solar Pump System PS1800 C-SJ5-8
C-SJ5-8
- 1% cable loss
Calculation of system performance is based on:- non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30C
10/335 /16.5
15/49.5
Wp
1000
900
800
700
600
500
400
300
10
20
30
40
50
60
70
2500
5000
10000
7500
12500
15000
17500
20/66
25/82.5
30/100
35/115.5
40/132
45/148.5
50/165
80
-
7/28/2019 21_3_PS1800 Bomba Solar Sumergible
5/10
System PerformanceAn irradiation value and the required head in metersare given for a certain solar pumping system.By connecting the point for the power output in Wpof the solar array with an irradiation value, movevertical upwards to the intersection with the requiredhead curve, then horizontal to the left to find thedaily quantity of water that can be pumped ( m/day)
Or the other way:
By starting from the daily required water amounthorizontally to the intersection of the required head,then vertically down to the intersection with theexpected solar irradiation, then horizontally to theleft to find the required output of the solar array.
Motor
The LORENTZ submersible motor, type EC1200-C is a 2 pole synchronous brushless DCmotor. Slide ring bearing and ceramic trustbearings are water lubricated.The motor raw earth magnets are hermeticallysealed in stainless steel and encapsulated insynthetic resin.The motor is pressure compensated and thereare no practical depth limitations for
submergence.No electronics are inside the motor and theentire motor is water filled.
Data:Voltage: 3 X 100V electronically commutatedPower: 1,4kW / 2HP
0,0
1,0
2,0
3,0
4,0
5,0
6,0
7,0
8,0
9,0
10,0
11,0
12,0
0 200 400 600 800 1000 1200 1400 1600DC power [W]
flowr
ate[m/h]
0
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
2600
2800
3000
flowr
ate[USgal/h]
PS1800 C-SJ5-8 (Item No. 1162 ) for Solar Operation(Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 200V DC)
5 m / 16 ft
10 m / 33 ft
15 m / 49 ft
20 m / 66 ft
25 m / 82 ft
30 m / 98 ft
35 m / 115 ft
40 m / 131 ft
45 m / 148 ft
50 m / 164 ft
Instantaneous Output Average Values
A B C D Emax BSP
SJ 5A-8 525 186 339 96 98 1 1/2" 11,2 kg
Pump TypeMinimum Internal Diameter
of BoreholeWeight
4" (104mm)
Dimensions [mm]
-
7/28/2019 21_3_PS1800 Bomba Solar Sumergible
6/10
Head Metres /Ft.
US
GPD m/day
Direct operated PV-Pump System :
Solar Pump System PS1800 C-SJ8-5
C-SJ8-5
- 1% cable loss
Calculation of system performance is based on:
- non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30C
10/33
5 /16.5
15/49.5
Wp
1000
900
800
700600
500
400
300
10
20
30
40
50
60
70
5000
10000
15000
20/66
25/82.5
30/100
80
90
100
110
120
130
20000
25000
30000
-
7/28/2019 21_3_PS1800 Bomba Solar Sumergible
7/10
System Performance
An irradiation value and the required head in metersare given for a certain solar pumping system.By connecting the point for the power output in Wpof the solar array with an irradiation value, movevertical upwards to the intersection with the requiredhead curve, then horizontal to the left to find thedaily quantity of water that can be pumped ( m/day)
Or the other way:
By starting from the daily required water amounthorizontally to the intersection of the required head,then vertically down to the intersection with theexpected solar irradiation, then horizontally to theleft to find the required output of the solar array.
Motor
The LORENTZ submersible motor, type EC1200-C is a 2 pole synchronous brushless DCmotor. Slide ring bearing and ceramic trustbearings are water lubricated.The motor raw earth magnets are hermeticallysealed in stainless steel and encapsulated insynthetic resin.The motor is pressure compensated and thereare no practical depth limitations for
submergence.No electronics are inside the motor and theentire motor is water filled.
Data:Voltage: 3 X 100V electronically commutatedPower: 1,4kW / 2HP
0
2
4
6
8
10
12
14
16
18
0 200 400 600 800 1000 1200 1400 1600DC power [W]
flowr
ate[m/h]
0
500
1000
1500
2000
2500
3000
3500
4000
4500
flowra
te[USgal/h]
PS1800 C-SJ8-5 (Item No. 1164) for Solar Operation(Solar generator: Nominal volt age 72 to 96 V DC, open circu it vo ltage max. 200V DC)
5 m / 16 ft
10 m / 33 ft
15 m / 49 ft
20 m / 66 ft
25 m / 82 ft
30 m / 98 ft
Instantaneous Output Average Values
A B C D Emax BSP
SJ 8A-5 601 186 415 96 98 2" 12,7 kg
Pump TypeMinimum Internal Diameter
of BoreholeWeight
4" (104mm)
Dimensions [mm]
-
7/28/2019 21_3_PS1800 Bomba Solar Sumergible
8/10
Head Metres /Ft.
USGPD m/day
Direct operated PV-Pump System :Solar Pump System PS1800 C-SJ12-3
C-SJ12-3
- 1% cable loss
Calculation of system performance is based on:
- non tracked PV-generator, (see ETATRACK for increasing performance)- 11h standard solar day- ambient average temperature of 30C
12.5/41
10/33
7.5/25
5 /16.5
15/50
Wp
800
700
600
500400
300
20
40
60
80
100
120
140
160
180
200 2.5/8
5000
10000
20000
15000
25000
30000
35000
40000
45000
50000
-
7/28/2019 21_3_PS1800 Bomba Solar Sumergible
9/10
System Performance
An irradiation value and the required head in metersare given for a certain solar pumping system.By connecting the point for the power output in Wpof the solar array with an irradiation value, movevertical upwards to the intersection with the requiredhead curve, then horizontal to the left to find thedaily quantity of water that can be pumped ( m/day)
Or the other way:
By starting from the daily required water amounthorizontally to the intersection of the required head,then vertically down to the intersection with theexpected solar irradiation, then horizontally to theleft to find the required output of the solar array.
Motor
The LORENTZ submersible motor, type EC1200-C is a 2 pole synchronous brushless DCmotor. Slide ring bearing and ceramic trustbearings are water lubricated.The motor raw earth magnets are hermeticallysealed in stainless steel and encapsulated insynthetic resin.The motor is pressure compensated and thereare no practical depth limitations for
submergence.No electronics are inside the motor and theentire motor is water filled.
Data:Voltage: 3 X 100V electronically commutatedPower: 1,4kW / 2HP
0
2
4
6
8
10
12
14
16
18
20
22
24
0 200 400 600 800 1000 1200 1400 1600DC power [W]
flowr
ate[m/h]
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
flowra
te[USgal/h]
PS1800 C-SJ12-3 (Item No. 1166) for Solar Operation(Solar generator: Nominal volt age 72 to 96 V DC, open circu it vo ltage max. 200V DC)
5 m / 16 ft
10 m / 33 ft
15 m / 49 ft
12,5 m / 41 ft
7,5m / 25 ft
Instantaneous Output Average Values
A B C D Emax BSP
SJ 12A-3 566 186 380 96 98 2" 12,5 kg
Pump TypeMinimum Internal Diameter
of BoreholeWeight
4" (104mm)
Dimensions [mm]
-
7/28/2019 21_3_PS1800 Bomba Solar Sumergible
10/10
Depth of Well
Tank Height
Well to Basin
Cable Length
Trans. Pipe Diameter
Riser Pipe Diameter
Well Diameter
Trans. Pipeline Length
Static Level
Drawdown
Pump Intake Depth