NCR RealPOS 82XRT (7606)
Release 1.1
Site Preparation Guide
B005‐0000‐2086
Issue B
![Page 2: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/2.jpg)
The product described in this book is a licensed product of NCR Corporation.
NCR is a registered trademark of NCR Corporation. NCR RealPOS is a trademark of NCR Corporation in the United States and/or other countries. Other product names mentioned in this publication may be trademarks or registered trademarks of their respective companies and are hereby acknowledged.
Where creation of derivative works, modifications or copies of this NCR copyrighted documentation is permitted under the terms and conditions of an agreement you have with NCR, NCRʹs copyright notice must be included.
It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware become available. NCR, therefore, reserves the right to change specifications without prior notice.
All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR representative or NCR office for information that is applicable and current.
To maintain the quality of our publications, we need your comments on the accuracy, clarity, organization, and value of this book.
Address correspondence to:
Manager, Information Solutions GroupNCR CorporationDiscovery Centre, 3 Fulton RoadDundee, DD2 4SWScotland
Internet Address:
http://www.info.ncr.com/eFeedback.cfm
Copyright © 2011By NCR CorporationDuluth, GA U.S.A.All Rights Reserved
![Page 3: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/3.jpg)
iii
PrefaceThis is a contractual document. It contains important warnings and confers important
legal rights and obligations. You are advised to read it carefully.
It is the responsibility of the customer to ensure that all installation preparations are
complete and in compliance with NCR specifications and requirements and all
applicable national, state, or local codes, regulations, and laws.
Notice: This document is NCR proprietary information and is not to be disclosed or
reproduced without consent.
Safety RequirementsThe NCR RealPOS 82XRT conforms to all applicable legal requirements. To view the
compliance statements see the NCR RealPOS Terminals Safety and Regulatory Statements
(B005‐0000‐1589).
The on/off switch is a logic switch only. The AC line voltage primaries are live at all
times when the power cord is connected. Therefore, disconnect the AC power cord
before opening the unit to install features or service this terminal.
Peripheral UsageThis terminal should only be used with peripheral devices that are certified by the
appropriate safety agency for the country of installation (UL, CSA, TUV, VDE) or those
which are recommended by NCR Corporation.
References• NCR RealPOS 82XRT User Guide (B005‐0000‐2085)
• NCR RealPOS 82XRT Hardware Service Manual (B005‐0000‐2087)
• NCR RealPOS 82XRT Parts Identification Manual (B005‐0000‐2088)
Revision Record
Issue Date Remarks
A Mar 2012 First Issue
B Aug 2012 Release 1.1
![Page 4: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/4.jpg)
iv
About this BookThis book provides site preparation information for NCR RealPOS 82XRT components.
This book does NOT provide Peripheral component and AC wiring site preparation
information. A list of the associated reference documents is in the Related Site
Preparation Data section.
This book contains the information necessary for the preparation of a site conforming
to the NCR specifications. It is very important that the site complies with the
requirements specified in the document because, once the equipment has been
installed, deficiencies in site preparation or the problems caused by these deficiencies
are much more difficult to detect and correct. Further, failure to comply with these
requirements or to take proper steps to protect equipment against risks identified in
this document may cause serious damage to the equipment and to the customerʹs
business.
In addition to the need to comply with the requirements specified, electrical wiring
and mechanical systems must also comply with all relevant codes, laws, and
regulations.
It is important that a customer or his agent who is fully conversant with the special
requirements of electronic equipment prepare the site. The responsibility of ensuring
that the site is prepared in compliance with this document remains with the customer.
For information and guidance purposes only, a list is provided, in general terms, of
those matters for which the customer is responsible. This list does not intend to be
comprehensive, and in no way modifies, alters, or limits the responsibility of the
customer for all aspects of adequate site preparation.
NCR staff is available to answer questions relating to the contents of this document
except where:
• a customer has been notified that a full or partial consultancy service is available
and/or that NCR is willing to undertake a preliminary or final site survey and
• the customer shall have entered into a formal contract with NCR for provision of
the same.
No comment, suggestion, or advice offered or not offered about preparation of the site
nor any inspection of the site whether before or after preparation is to be taken as
approval of the location of the site and equipment or its preparation and NCR is not
liable in respect of any comment, suggestion, or advice given by its staff or in respect to
any failure to give advice.
Finally, only the customer can know the full extent of damage, which may be caused to
his business because of failure of the equipment that is to be installed. For this reason,
it is the customerʹs responsibility to ascertain the extent of any possible damage to his
existing or planned business, and to effect full insurance in respect of it.
![Page 5: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/5.jpg)
v
Table of Contents
Chapter 1: NCR RealPOS 82XRT Terminal Site Preparation
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐1
Model Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐2
Customer Responsibilities. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐3
Third Party Peripheral Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐4
LAN Communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐4
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐5
Base Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐5
Integrated Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐5
Integrated Terminal w/Cash Drawer . . . . . . . . . . . . . . . . . . . . . . . 1‐6
7459‐K320 Vertical Mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐7
5954 15‐Inch DynaKey. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐8
Standard Remote Table Top Mount (5964‐K030/K031) . . . . . 1‐8
NCR 5964‐K038/K039 Checkstand Mount . . . . . . . . . . . . . . . . 1‐9
NCR 5942 12.1‐Inch LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐10
NCR 5943 12‐Inch LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐10
NCR 5964 12‐Inch Touch LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐11
Standard Remote Table Top Mount (5964‐K031/032) . . . . . 1‐11
NCR 5966 15‐Inch Touch LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐12
NCR 5966 with Table Top Mount . . . . . . . . . . . . . . . . . . . . . 1‐12
NCR 5966 with 5964‐K030/K031 Table Top Mount . . . . . . . 1‐12
NCR 5982 6.5‐Inch Color LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐13
Customer Displays. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐14
NCR 5975‐1xxx 2x20 Remote Customer Display . . . . . . . . . . . . 1‐14
NCR 5975‐2xxx Graphical Remote Customer Display . . . . . . . . 1‐15
NCR 5976‐1xxx 2x20 Remote Customer Display . . . . . . . . . . . . 1‐16
Keyboards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐17
NCR 5932‐2xxx 64‐Key POS Keyboard . . . . . . . . . . . . . . . . . 1‐17
NCR 5932‐5xxx USB Big Ticket POS Keyboard . . . . . . . . . . 1‐17
NCR 5932‐6xxx 104‐Key Compact Alphanumeric Keyboard1‐18
NCR 5932‐7xxx PS/2 78‐Key POS Keyboard . . . . . . . . . . . . . 1‐18
NCR 7459‐K317/K318 Keyboard Filler Plate . . . . . . . . . . . . . 1‐18
Printers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐19
NCR 7167 Thermal Receipt and Impact Slip Printer . . . . . . 1‐19
NCR 7168 Thermal Receipt and Impact Slip Printer . . . . . . 1‐19
NCR 7197 Thermal Receipt Printer. . . . . . . . . . . . . . . . . . . . . 1‐20
NCR 7198 Thermal Receipt Printer. . . . . . . . . . . . . . . . . . . . . 1‐20
NCR 7162 Multifunction Impact Printer . . . . . . . . . . . . . . . . 1‐21
![Page 6: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/6.jpg)
vi
Cash Drawers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐22
NCR 2181 Cash Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐22
NCR 2185 Flip Top Drawer . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐22
NCR 2186 Compact Cash Drawer. . . . . . . . . . . . . . . . . . . . . . 1‐23
Environmental Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐24
Barometric Pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐24
Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐24
Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐24
Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐25
7606 Terminal Power Requirements . . . . . . . . . . . . . . . . . . . . . . . 1‐25
Peripheral Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐25
AC Store Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐25
TComponent Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐26
Shipping Weight Estimate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐27
Service Clearance Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐27
Airflow Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1‐28
Appendix A: Transient Protection
![Page 7: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/7.jpg)
NCR RealPOS 82XRT Terminal Site Preparation
IntroductionThis document provides the information necessary to prepare a site to NCR
specifications prior to installing an NCR RealPOS 82XRT Terminal (also referred to as
the NCR 7606). Prepare the site properly before installing the terminal because site
preparation deficiencies may be difficult to detect and correct after installation.
The NCR 7606 consists of separate pieces that may be combined in a variety of
configurations. Certain combinations are mutually exclusive. You must determine the
equipment that will actually be installed before proceeding with the site preparation.
![Page 8: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/8.jpg)
2 NCR RealPOS 82XRT Terminal Site Preparation
Model Numbers
Major Model CPU
7606‐1002 Intel Celeron G540, 2.5 GHz, 2GB DDR3 1033MHz memory, Diskless,
80Plus Gold Power Supply, US power cord only, Beige
7606‐1007 Intel Celeron G540, 2.5 GHz, 2GB DDR3 1033MHz memory, Diskless,
80Plus Gold Power Supply, US power cord only, Charcoal
7606‐1110 Intel Celeron G540, 2.5 GHz, 2GB DDR3 1033MHz memory, Diskless,
UPS Ready, Beige
7606‐1302 Intel Pentium G850, 2.9 GHz, 2GB DDR3 1033MHz memory, Diskless,
80Plus Gold Power Supply, Beige
7606‐1307 Intel Pentium G850, 2.9 GHz, 2GB DDR3 1033MHz memory, Diskless,
80Plus Gold Power Supply, Beige
7606‐1507 Intel Core‐i3 2120, 3.3 GHz, 2GB DDR3 1033MHz memory, Diskless,
80Plus Gold Power Supply, Charcoal
7606‐1707 Intel Core‐i5 2400, 3.1 GHz, 2GB DDR3 1033MHz memory, Diskless,
80Plus Gold Power Supply, Charcoal
![Page 9: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/9.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 3
Customer ResponsibilitiesBefore installing the system, the customer must perform or provide the following:
• When required by NCR, provide the NCR Customer Services representative with
appropriate drawings that indicate:
• Equipment location
• Site wiring (power and communications, paths and lengths)
• Location of other equipment that may generate electrical noise, electromagnetic
interference, or heat
• Make building alterations necessary to meet wiring and other site requirements
• Provide and install all communications cables, wall jacks, special connectors, and
associated hardware
• Provide and install necessary power distribution boxes, conduits, grounds,
lightning protection devices, and associated hardware
• Ensure all applicable codes, regulations, and laws (including, but not limited to,
electrical, building, safety, and health) are met
• Provide and install auxiliary power or other equipment as required
• Provide storage or service areas as required
• Meet all system/unit environmental requirements
• Provide and install floor coverings and environment systems that limit or control
static electricity build‐up and discharge
In general, keep the NCR equipment area free from dust, smoke, lint, and other
particles. Restrict smoking, eating, and drinking around the equipment. Avoid
locating the equipment near other machines that generate ink, carbon, and paper dust
particles.
![Page 10: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/10.jpg)
4 NCR RealPOS 82XRT Terminal Site Preparation
Third Party Peripheral CertificationThird party peripherals must be certified with the POS terminal or a potential ESD
issue can occur. Third party peripherals include any electrically powered devices
connected to the POS terminal that is not an NCR branded product or a certified
solution advocated by NCR. Examples of third party products include printers,
external CD‐ROM drives, cash drawers, cigarette boxes, pin pad devices, etc.
Peripherals tend to be less sensitive to electrostatic damage when directly grounded
through their power cords. If the peripheral is powered by the terminal and has no
dedicated ground, then all of the ESD energy is coupled into the port connection.
Some devices may require the use of an in‐line galvanic isolator/surge protector in
order to prevent problems.
The NCR TPP/SCER process is designed to evaluate third party peripherals and
determine whether additional protective devices are needed.
The NCR Workstation and Peripherals AC Wiring Guide (BST0‐2115‐53) contains
additional information on this subject.
LAN CommunicationsThe NCR 7606 Terminal supports Ethernet 10/100/1000baseT Local Area Network
(LAN) communication protocol. For Ethernet communications wiring specifications,
refer to the NCR Ethernet Communication Wiring Guide (BST0‐2118‐82).
![Page 11: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/11.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 5
Dimensions
Base Unit
Integrated Terminal
30597
340 mm(13.4 in.)
394 mm(15.5 in.)
115 mm(4.5 in.)
30598
442 mm(17.4 in.)
B
472 mm(18.6 in.)
500 mm(19.7 in.)
A
508 mm(20.0 in.)
673 mm(26.5 in.)
Dimension 5964 (12”) 5954 (15”)
612 mm(24.1 in.)
A
B
500 mm(19.7 in.)
570 mm(22.4 in.)
608 mm(23.9 in.)
5965 (15”) 5943 (12”)
630 mm(24.8 in.)
525 mm(20.7 in.)
![Page 12: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/12.jpg)
6 NCR RealPOS 82XRT Terminal Site Preparation
Integrated Terminal w/Cash Drawer
30599
442 mm(17.4 in.)
B
472 mm(18.6 in.)
500 mm(19.7 in.)
A
622 mm(24.5 in.)
673 mm(26.5 in.)
Dimension 5964 (12”) 5954 (15”)
612 mm(24.1 in.)
A
B
673 mm(24.2 in.)
690 mm(27.2 in.)
608 mm(23.9 in.)
5965 (15”) 5943 (12”)
630 mm(24.8 in.)
645 mm(25.4 in.)
![Page 13: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/13.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 7
7459-K320 Vertical Mount
30620
386 mm(15.2 in.)
378 mm(14.9 in.)198 mm
(7.8 in.)
![Page 14: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/14.jpg)
8 NCR RealPOS 82XRT Terminal Site Preparation
5954 15-Inch DynaKey
Standard Remote Table Top Mount (5964-K030/K031)
23875a
495 mm(19.5 in.)
335 mm(13.2 in.)
295 mm(11.6 in.)
507 mm(20.0 in.)
DynaKey w/MSR
DynaKey w/o MSR
![Page 15: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/15.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 9
NCR 5964-K038/K039 Checkstand Mount
The Checkstand Mount is fully adjustable between the minimum and maximum
dimensions that are illustrated below. The DynaKey can also be rotated right and left
of center (shown) by approximately 90 degrees, as well as tilted from a vertical
position to approximately 45 degrees (shown).
19909b
213 mm(8.4 in.)
216 mm(8.5 in.)
400 mm(15.75 in.)
330 mm(13.0 in.)
370 mm(14.5 in.)
480 mm(19.0 in.)
38 mm1.5 in.
7.6.mm0.30 in.
70 mm2.75 in.
89 mm3.5 in.
114 mm4.25 in.
![Page 16: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/16.jpg)
10 NCR RealPOS 82XRT Terminal Site Preparation
NCR 5942 12.1-Inch LCD
NCR 5943 12-Inch LCD
19810b
306 mm(12.0 in.)
304 mm(11.9 in.)
190 mm(7.5 in.)
133 mm(5.25 in.)
165 mm(6.5 in.)
47 mm(1.9 in.)
13 mm(0.5 in.)
229 mm(9.0 in.)
280 mm(11.0 in.)
292 mm(11.5 in.)
254 mm(10.0 in.)
292 mm(11.5 in.)
329 mm(12.9 in.)
![Page 17: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/17.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 11
NCR 5964 12-Inch Touch LCD
Standard Remote Table Top Mount (5964-K031/032)
21209a
![Page 18: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/18.jpg)
12 NCR RealPOS 82XRT Terminal Site Preparation
NCR 5966 15-Inch Touch LCD
NCR 5966 with Table Top Mount
NCR 5966 with 5964-K030/K031 Table Top Mount
27328
220 mm(8.7 in.)
400 mm(15.7 in.)
358 mm(14.1 in.)
394 mm(15.5 in.)
220 mm(8.7 in.)
180 mm(7.1 in.)
27327
220 mm(8.7 in.)
400 mm(15.7 in.)
358 mm(14.1 in.)
394 mm(15.5 in.)
230 mm(9.0 in.)
254 mm(10.0 in.)
![Page 19: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/19.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 13
NCR 5982 6.5-Inch Color LCD
23158
174 mm(6.9 in.)
140 mm(5.5 in.)
192 mm(7.6 in.)
140 mm(5.5 in.)
![Page 20: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/20.jpg)
14 NCR RealPOS 82XRT Terminal Site Preparation
Customer Displays
NCR 5975-1xxx 2x20 Remote Customer Display
22915
180 mm(7.1 in.)
216 mm(8.5 in.)
123 mm(4.8 in.)
81 mm(3.2 in.)
151 mm(5.9 in.)
![Page 21: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/21.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 15
NCR 5975-2xxx Graphical Remote Customer Display
22916
224 mm(8.9 in.)
229 mm(9.0 in.)
123 mm(4.8 in.)
93 mm(3.7 in.)
151 mm(5.9 in.)
![Page 22: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/22.jpg)
16 NCR RealPOS 82XRT Terminal Site Preparation
NCR 5976-1xxx 2x20 Remote Customer Display
30824
159 mm(6.6 in.)
80 mm(3.2 in.)
123 mm(4.8 in.)
211 mm(8.3 in.)
153 mm(6.0 in.)
![Page 23: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/23.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 17
Keyboards
NCR 5932-2xxx 64-Key POS Keyboard
NCR 5932-5xxx USB Big Ticket POS Keyboard
11413a
184 mm(7.2 in.)
335 mm(13.2 in.)
42 mm(1.7 in.)
19716a
184 mm(7.2 in.)
455 mm(17.9 in.) 42 mm
(1.7 in.)
![Page 24: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/24.jpg)
18 NCR RealPOS 82XRT Terminal Site Preparation
NCR 5932-6xxx 104-Key Compact Alphanumeric Keyboard
NCR 5932-7xxx PS/2 78-Key POS Keyboard
NCR 7459-K317/K318 Keyboard Filler Plate
21317a
184 mm(7.25 in.)
365 mm(14.4 in.)
45 mm(1.7 in.)
22049a
188 mm(7.4 in.)
283 mm(11.1 in.)
47 mm(1.9 in.)
25207
432 mm(17 in.) 185 mm
(7.3 in.)
![Page 25: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/25.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 19
Printers
NCR 7167 Thermal Receipt and Impact Slip Printer
NCR 7168 Thermal Receipt and Impact Slip Printer
19711g
190 mm(7.5 in.)
174 mm(7.0 in.)
262 mm(10.3 in.)
316 mm(12.5 in.)
275 mm10.8 in.
23537a
OK
346 mm(13.6 in.)
190 mm(7.5 in.)
181 mm(7.1 in.)
300 mm(11.8 in.)
![Page 26: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/26.jpg)
20 NCR RealPOS 82XRT Terminal Site Preparation
NCR 7197 Thermal Receipt Printer
NCR 7198 Thermal Receipt Printer
19712g
146 mm(5.75 in.)
156 mm(6.25 in.)
184 mm(7.25 in.)
255 mm10.1 in.
23834c
256 mm(10.1 in.)
145 mm(5.7 in.)
220 mm(8.7 in.)
139 mm(5.5 in.)
![Page 27: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/27.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 21
NCR 7162 Multifunction Impact Printer
15410a
250 mm(11.7 in.)
297 mm(11.7 in.)
191 mm(7.5 in.)
142 mm(5.6 in.)
![Page 28: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/28.jpg)
22 NCR RealPOS 82XRT Terminal Site Preparation
Cash Drawers
NCR 2181 Cash Drawer
NCR 2185 Flip Top Drawer
24799
762 mm(30.0 in.)
442 mm(17.4 in.)
467 mm(18.7 in.)
117 mm(4.6 in.)
w/feet:
127 mm(5.0 in.)
23535
460 mm18.1 in.
254 mm10.0 in.
172 mm6.8 in.
![Page 29: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/29.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 23
NCR 2186 Compact Cash Drawer
23150a
700 mm(27.6 in.)
415 mm(16.3 in.)
411 mm(16.2 in.)
110 mm(4.3 in.)
![Page 30: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/30.jpg)
24 NCR RealPOS 82XRT Terminal Site Preparation
Environmental Requirements
Barometric PressureThe terminal operates within the following barometric pressure conditions:
• Maximum operating altitude: 3,000 m (9,843 ft.)
• Operating range of pressure: 105 to 69 kPa (15.2 to 10.0 lb./in.)
TemperatureThe terminal operates over the temperature ranges shown below. Avoid continuous
operation at, near the indicated temperature extremes, or in locations where the
temperature changes beyond the restrictions.
HumidityThe terminal operates within the humidity ranges shown below. Avoid continuous
operation at, near the indicated humidity extremes, or in locations where the
humidity changes beyond the restrictions. Never expose the terminal to
condensation.
Temperature Parameter Restriction
Operating 5C to 40C (41F to 104F), dry bulb
Storage ‐10C to 50C (14F to 122F), three months
Shipping ‐40C to 60C (‐40F to 140F), one week
Humidity Type Restriction
Relative 10% to 90%
Maximum change rate 10%/60 minutes
Storage 10% to 90% relative humidity, three months
Shipping 5% to 95% relative humidity, one week
![Page 31: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/31.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 25
Electrical Requirements
7606 Terminal Power RequirementsThe terminalʹs external power supply has a maximum output of 150 Watts and
provides power to the terminal and its powered peripherals.
Caution: Locate the power supply away from other electrical equipment, away from
heat sources, away from possible liquid spills, and where there is adequate clearance
for cooling.
Note: The RealPOS 82XRT does not offer an AC convenience outlet for CRT power. A
separate country‐specific power cord must be ordered separately. Available NCR
power cords are described in the System Cables section.
Peripheral Power RequirementsThe number of peripherals that the terminal can support is dependent upon which
peripherals are connected. For planning purposes, use the RealPOS 82XRT (7606)
Release 1.0 Power Matrix (B005‐0000‐2089) for details on total power distribution.
Note: This file requires Microsoft Excel to run.
AC Store Wiring RequirementsThe customer must provide suitable AC power for the terminals, associated
equipment, and devices. We recommend a dedicated unswitched power line
dedicated to the NCR equipment installation. Refer to the NCR Workstation and
Peripherals AC Wiring Guide (BSTO‐2115‐53) for store AC wiring requirements. The
AC outlet must be installed near the terminal and easily accessible to the operator.
Range Nominal Vrms Minimum Vrms Maximum Vrms
LOW (115) 100‐127 90 136
HIGH (230) 200‐240 180 265
![Page 32: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/32.jpg)
26 NCR RealPOS 82XRT Terminal Site Preparation
TComponent Weights
Terminal Component Weight kg (lbs.)
7606 Terminal w/Batteries 10.7 (23.5)
7606 Terminal w/o Batteries 8.8 (19.3)
Integrated Tray Kit 8.6 (18.0)
2181 Cash drawer 6.0 (13.3)
2185 Cash Drawer 12.3 (27.0)
2186 Cash drawer 12.3 (27.0)
64‐Key Keyboard 0.9 (1.9)
78‐Key Keyboard 1.1 (2.4)
Big Ticket Keyboard 1.0 (2.15)
104‐Key Compact Keyboard 1.4 (3.0)
5975‐1xxx Customer Display 11.9 (26.5)
5975‐2xxx Customer Display 0.5 (1.2)
5976‐1xxx Customer Display 0.3 (0.6)
5942 12.1” Touch LCD 2.8 (6.2)
5943 12.1” LCD 2.1 (4.8)
5965 Touch LCD 4.0 (8.8)
5966 Touch Monitor 5.4 (11.9)
7167 Receipt/Impact Printer 4.5 (10.0)
7168 Receipt/Impact Printer 5.0 (11.0)
7197 Thermal Receipt Printer 1.5 (3.4)
7198 Thermal Receipt Printer 2.2 (4.9)
![Page 33: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/33.jpg)
NCR RealPOS 82XRT Terminal Site Preparation 27
Shipping Weight EstimateTo obtain the total maximum weight of a specific configuration, add the weights of
the appropriate individual components. The following table provides an example.
Service Clearance Requirements
Terminal Component Weight kg (lbs.)
Integrated Terminal w/Batteries 13.0 (35.0)
5942 12.1‐Inch LCD 2.8 (6.2)
5975‐2xxx Customer display 0.5 (1.2)
64‐Key keyboard 0.9 (1.9)
7167 Receipt/Impact Printer 4.5 (10.0)
Total 21.7 (54.3)
Miscellaneous items and
shipping materials
5.2 (11.5)
Shipping total 26.9 (65.8)
DeviceAbove mm (in.)
Left Side mm (in.)
Right Side mm (in.)
Front mm (in.)
Behind mm (in.)
Terminal Base ‐ ‐ 100 (4.0) 100 (4.0) 100 (4.0)
Keyboard ‐ ‐ 100 (4.0) ‐ ‐
Cash Drawer ‐ ‐ ‐ 330 (13.0) ‐
7162 Printer 325 (13.0) 300 (12.0) ‐ 100 (4.0) 25 (1.0)
7167 Printer 305 (12) 305 (12) ‐ ‐ ‐
7168 Printer 305 (12) 305 (12) ‐ ‐ ‐
7197 Printer 267 (10.5) ‐ ‐ ‐
5953 DynaKey 50 (2) 25 (1) 100 (4) ‐ ‐
5942/43 LCD 50 (2) 25 (1) 25 (1.0) ‐ ‐
5964 Touch LCD 50 (2) 25 (1) 100 (4) ‐ ‐
5975 Display 25 (1.0) ‐ 25 (1.0) ‐ ‐
![Page 34: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/34.jpg)
28 NCR RealPOS 82XRT Terminal Site Preparation
Airflow RequirementsDo not block the air vents on the terminal. These vents are necessary for cooling.
Do not place the terminal in an enclosed area where sufficient ventilation is not
available. Leave at least 100 mm (4 inches) of clearance on sides where air vents are
located.
When the terminal is wall‐mounted, the rear cover must have at lease 6 mm (0.25 in.)
clearance from the wall. The mounting mechanism must not block the vent holes on
the rear cover.
24089a
![Page 35: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/35.jpg)
Appendix A: Transient Protection
AC Power Line Transient ProtectionIn the process of power distribution, transient electrical energy (including, but not
limited to, lightning strikes, intermittent short circuits, and switching transients) can
be introduced onto power lines. Such transient energy can be very damaging to
electronic hardware, and can also cause data corruption. Under these circumstances,
NCR recommends the use of AC power transient suppressors. Such protection
devices are intended to guard against power line transients that can result in
hardware damage and various system or program errors.
Improvement of any deficiencies in power quality is a customer responsibility.
Malfunction and/or component failure as a result of power quality problems are/is
not covered by the NCR Maintenance Agreement. NCR accepts no liability for any
such occurrence nor for its consequences.
When power transient suppression is required, the suppressors used should meet the
following minimum requirements:
• Dissipate energy to match the appropriate location categories as defined by IEEE
Standard C.62.41.2‐2002.
• Be of the voltage limiting (clipping), or tracking filter type. The suppressor must
not clamp the voltage to zero, and must self‐recover after the passage of the
transient. The suppressor may be of the hybrid type construction that makes use
of various technologies in order to meet speed and dissipation requirements.
• TranUpon failure, exhibit a positive indication of its failure such as a blown fuse
or tripped breaker.
• Be listed by the accepted safety organization for the country involved (UL, CSA,
VDE, ETL, and so on) and the installation must conform to local, state, and
national electrical
![Page 36: 2086b](https://reader030.fdocuments.us/reader030/viewer/2022020200/55cf9c6c550346d033a9cb1b/html5/thumbnails/36.jpg)
2
Data Line Transient ProtectionThe nature of the transient phenomenon may extend to the data communication lines
connected to this equipment. It is the responsibility of the customer to install and
connect a data line transient suppression system to correct or prevent any
deficiencies. Such systems must meet the following minimum requirements:
• Be of the voltage limiting type and must self‐recover after passage of the transient.
• Must be designed to avoid signal degradation for the given interface they are
attached to.
• Be installed in accordance with all applicable local, state, and national electrical
codes and regulation.
Note: NCR provides a full line of both AC power and data line transient surge
suppressors to protect your RealPOS system and reduce downtime and extend the
life of the RealPOS Retail Solution. For sizing and product information, please call
NCR Site Preparation Services at 800‐257‐0458.
The following product offerings are available from NCR Site Preparation Services:
• UPS ‐Uninterruptible Power Systems
• Provides battery backup for power outages and brownouts.
• Includes AC and data line surge protection.
• If needed, certain models provide basic voltage regulation.
• Small size provides easy installation.
• Line Conditioners / Filters
• Incorporates an Isolation transformer or filter that provides 100% isolation
from disturbances on the incoming AC power line.
• Removes EMI/RFI noise that causes equipment lockups.
• Reduces common mode noise issues and surges/transients.
• Significantly reduces POS downtime and component failure.
• Transient Voltage Surge Suppressors
Provides protection from catastrophic AC surges/transients.
• Provides data line protection from catastrophic surges that can migrate onto
the data line and network.