2020 - Thames Restek · an application-specific column. Here are a few of Restek’s most popular...
Transcript of 2020 - Thames Restek · an application-specific column. Here are a few of Restek’s most popular...
Must-Have Products for Your Lab
SSENTIALSESSENTIALS2020.2
www.thamesrestek.co.ukPure Chromatography
Maintain LC-MS Performance with Restek Accessories
Take the Choice Out of Column Selection with Application-Specific LC Columns
A Wide Variety of Vials, Caps, and Septa for Your Lab
Find more vials and accessories at www.restek.com/vials2
Optimize Crimping Power Crisp OLED screen display lets you optimize crimping power for each cap type, monitor battery use, and view lifetime statistics.
High-Power Electronic Crimping Tool with OLED Display Screen
• Fixed power supply provides steady, reliable power. Available with cords for several regions.
• Interchangeable jaw sets allow you to buy only the size crimper or decapper you need.
Description qty. cat.# Price £High-Power Electronic Crimping Tool with OLED Display Screen, power cable for United Kingdom ea. 23236-UK £1,994.35
Description Size qty. cat.# Price £Electronic Rechargeable Crimper with OLED Display Screen 11 mm kit 23234 £1,068.80Electronic Rechargeable Crimper with OLED Display Screen 20 mm kit 23235 £1,068.80Electronic Rechargeable Decapper with OLED Display Screen 11 mm kit 23237 £1,068.80Electronic Rechargeable Decapper with OLED Display Screen 20 mm kit 23238 £1,068.80
Electronic Rechargeable Crimpers and Decappers with OLED Display Screen
• Hundreds of operations from one charge.• Large battery allows for faster charge cycle
and two sleep mode options extend battery life.
Learn more about Resprep PLR products at
www.restek.com/PLR
Simultaneously Remove Phospholipids and Proteins in One Resprep PLR SPE Procedure • Prevent signal suppression.• No analyte-specific method development.• Minimize contamination and maintenance.
From preparation to analysis, Restek is
proud to offer workflow solutions that help
provide accurate, reliable results.
Find power cables for more regions at www.restek.com
Description qty. cat.# Price £Resprep PLR SPE Cartridge, 25 mg/1 mL cartridge 100-pk. 28300 £186.00Resprep PLR SPE 96-Well Plate, 25 mg/2 mL each well ea. 28301 £176.70
High-Quality Vials Offer Exceptional Value for AnalystsRestek is proud to offer a selection of reliable, high-quality vials that are stored and shipped from here in the UK:
• Packed in a cleanroom
• High chemical resistance of the PP box to a number of acids, solvents, oils and fats
• No contamination of the vial by particles of the packaging, as PP is non-abrasive
• Full traceability through a batch numbering system
Learn more about the full range: www.thamesrestek.co.uk/latest-of-fers/729:vials
• Easy retrofit—replace TOV and TOV-2 valves without modification! • Proven long life—engineered to exceed 15,000 cycles.
• Leak-free performance—helium leak tested to 1x10-6 mL/sec.
• Effortless operation—finger turn for full valve closure (only 10 in-lb).
Go to www.restek.com/spme for SPME conversion kits, caps, septa, standards, and more. 3
Introduce Your Entech Sampling Canisters to Restek Air Valve Excellence (RAVE)
• Ideal for environmental monitoring, vapor intrusion, industrial hygiene, and personal air sampling.
• Higher uptake rates for excellent low-level sensitivity.• Higher capacity for accurate sampling up to 30 days.• Easy to use—no pump required.
Monitor a Wide Range of Chemicals with Easy-to-Use radiello Air Samplers
Description cat.#/kit Price £Starter kit: 1 complete sampler for BTEX/VOCs, CS2 desorption, white diffusive body, cartridge + blank, support plate, adaptor RAD130S £75.95
Starter kit: 1 complete sampler for 1,3-butadiene & isoprene, thermal desorption, yellow diffusive body, cartridge + blank, support plate, adaptor RAD141S £233.05
Starter kit: 1 complete sampler for BTEX/VOCs, thermal desorption, yellow diffusive body, cartridge + blank, support plate, adaptor RAD145S £244.20
Starter kit: 1 complete sampler for H2S, white diffusive body, cartridge + blank, support plate, adaptor RAD170S £83.75
These are just our starter kits; visit www.restek.com/radiello for our full selection!
• Enjoy longer lifetimes: Arrow construction protects the phase and minimizes both damage and analyte loss.
• Avoid downtime due to breakage.
• Eliminate septa coring.
Learn more at www.restek.com/spme
SPME Arrow:
Standard SPME Fibers
SPME Arrow
*These molecular weight ranges are a reasonable approximation; however, end users should verify suitability for their specific application.
Due to the relatively large diameter of Restek PAL SPME Arrows, you must modify the GC inlet using an instrument-specific conversion kit from Restek prior to use.
MaterialHub
ColorThickness
(µm)
Needle Diameter
(mm)Recommended
Analytes qty. cat.#Polydimethylsiloxane (PDMS) Red 100 µm 1.1 mm Volatile, 60–275 g/mol* ea. 27485Polydimethylsiloxane (PDMS) Red 100 µm 1.5 mm Volatile, 60–275 g/mol* ea. 27877Polydimethylsiloxane (PDMS) Black 250 µm 1.5 mm Volatile, 60–275 g/mol (high capacity)* ea. 27484Polyacrylate Gray 100 µm 1.1 mm Polar, semivolatile, 80–300 g/mol* ea. 27488
Carbon Wide Range (WR)/PDMS Light Blue 120 µm 1.1 mm Highly volatile, 30–225 g/mol* ea. 27487
Carbon Wide Range (WR)/PDMS Light Blue 120 µm 1.5 mm Highly volatile, 30–225 g/mol* ea. 27879
Divinylbenzene (DVB)/PDMS Violet 120 µm 1.1 mm Amines and polar compounds, 60–300 g/mol* ea. 27486
Divinylbenzene (DVB)/PDMS Violet 120 µm 1.5 mm Aromatic semivolatile, 60–300 g/mol* ea. 27878
DVB/Carbon WR/PDMS Dark Gray 120 µm 1.1 mm Volatile and semivolatile, 40–275 g/mol* ea. 27875
DVB/Carbon WR/PDMS Dark Gray 120 µm 1.5 mm Volatile and semivolatile, 40–275 g/mol* ea. 27876
SPME Arrow Method Development Kit
Set of 5 27489
Siltek-treated Price £ Stainless Steel Price £Description qty. cat.# cat.#1/4" Replacement Valve, RAVEn (2-Port) ea. 27377 £402.45 27376 £298.00 1/4" Replacement Valve, RAVEn (3-Port) ea. 27379 £428.55 27378 £321.05 RAVE and RAVEn Diaphragm Rebuild Kit (includes: diaphragms (3) kit 26390 £58.70 26389 £45.65
Replacement RAVEn Diaphragm ValvesFor Entech air sampling canisters
Browse our full line of LC columns at www.restek.com/LC 4
Eliminate the Impact of PFAS Instrument Contamination with a
Restek PFAS Delay Column• Traps system-related PFAS, preventing interference and
ensuring accurate trace-level analysis of PFAS in samples.
• Universal compatibility.
• Highly retentive of system-related PFAS; no breakthrough even with extended equilibration times.
Take the Choice Out of Column Selection with Application-Specific Allure LC ColumnsColumn phases like our industry-leading Biphenyl are rightfully popular for their versatility and separation power, but sometimes, a particularly tricky analysis calls for an application-specific column. Here are a few of Restek’s most popular LC columns specifically designed to tackle single applications.
Featured Application-Specific LC Columns:
Raptor C18 Performance: Speed, Efficiency, and Ruggedness in Action• A traditional end-capped C18 ideal for general-purpose use in
reversed-phase chromatography.
• Wide pH range (2–8) provides excellent data quality for many applications, matrices, and compounds.
• Offers the highest hydrophobic retention of any Raptor phase.
• Part of Restek’s Raptor LC column line featuring 1.8, 2.7, and 5 μm SPP core-shell silica.
Length2.1 mm
cat.#3.0 mm
cat.#4.6 mm
cat.# Price £1.8 µm Columns30 mm 9304232 — — £433.9550 mm 9304252 930425E — £471.40100 mm 9304212 930421E — £490.45150 mm 9304262 — — £502.952.7 µm Columns30 mm 9304A32 9304A3E 9304A35 £369.0550 mm 9304A52 9304A5E 9304A55 £401.20100 mm 9304A12 9304A1E 9304A15 £433.35150 mm 9304A62 9304A6E 9304A65 £464.905 µm Columns30 mm — 930453E — £368.2550 mm 9304552 930455E 9304555 £407.10100 mm 9304512 930451E 9304515 £445.95150 mm 9304562 930456E 9304565 £484.75250 mm — — 9304575 £580.40
Learn more at www.restek.com/raptor
Allure Aldehyde Ketone Column
Allure Organic Acids ColumnsAllure Acrylamide LC ColumnDescription cat.# Price £ 5 µm Columns50 mm, 2.1 mm ID 9167552 £545.60
Description cat.# Price £5 µm Columns200 mm, 4.6 mm ID 9159525-700 £819.00 (with Trident Inlet Fitting)
Description cat.# Price £5 µm Columns150 mm, 3.0 mm ID 916556E £732,155 µm Columns150 mm, 4.6 mm ID 9165565 £732.155 µm Columns250 mm, 4.6 mm ID 9165575 £780.805 µm Columns300 mm, 4.6 mm ID 9165585 £802.10 For more, visit www.restek.com/LC
Description cat.# Price £5 µm Columns
50 mm, 2.1 mm ID 27854 £354.15
Visit www.restek.com/standards to buy 1,000s of top-quality standards! 5
MegaMix Ampuls Set the Environmental Standard• Developed for the analysis of volatiles and semivolatiles (a.k.a., extractables).
• Maximized number of target analytes in a single ampul.
• Formulated and packaged for superior stability.
• Two independently produced lots in inventory for most mixes.
Conc. in Solvent and Volume cat.# Price £1,000 µg/mL each in methylene chloride (3-methylphenol and 4-methylphenol at 500 µg/mL), 1 mL/ampul 31850 £148.65
8270 MegaMix Standard (76 components)
For full compound lists and other MegaMix standards, go to
www.restek.com/megamix
Featured MegaMix Standard
Get More Uptime with Restek’s Long-Life ESI Electrode for Sciex Turbo V Sources
Custom Flexibility with Restek Reference Standards• More than 1/3 of the ampuls that leave our facility are custom orders—
almost all are certified reference materials (CRMs).
• ISO accreditation covers our catalog standards and your custom orders.
• Feasibility verification for every order.
• Top-quality, highly stable product whether it’s a stock, off-the-shelf standard or a one-of-a-kind, custom-formulated solution.
Accessories to Maintain LC-MS Performance
Description Model #Similar to
Sciex Part # qty. cat.# Price £
Long-Life ESI Electrode API 3200, 3500, 4000, 4500, 5000, 5500+, 6500, and 6500+ 025392 ea. 25831 £93.00
Description qty. cat.# Price £ESI Electrode Gauge for Sciex Turbo V Ion Sources ea. 25832 £16.75
ESI Electrode Gauge(for Sciex Turbo V Sources)
Description qty. cat.# Price £LC-MS/MS Infusion Kit kit 25755 £323.65
LC-MS/MS Infusion Kit
Description qty. cat.# Price £PEEK Connector, Luer Lock to 10-32 ea. 25830 £64.75
PEEK Connector, Luer Lock to 10-32
Quick-and-Easy Visual Confirmation of Electrode Exposure
Everything You Need to Put Together Your Own LC-MS/MS Infusion Rig
Connect PEEK Tubing to a Luer Lock Style Syringe
Request a custom standard at www.restek.com/solutions today!
Longer lifetimes mean higher sample throughput for your lab!
• Same chromatographic performance as original equipment.• Rugged electrode lasts longer and requires fewer replacements.
View testing results and learn more at www.restek.com/LongLifeESI
Rt-Msieve 5A Columns (fused silica PLOT)
Consistent flow restriction (F)
means reproducible results column to column.
Description temp. limits qty. cat.# Price £Rt-Msieve 5A 15 m, 0.25 mm ID, 20 µm to 300 °C ea. 19773 £774.25
Rt-Q-BOND Columns (fused silica PLOT)100% divinylbenzeneDescription temp. limits qty. cat.# Price £Rt-Q-BOND 30 m, 0.25 mm ID, 8 µm to 280/300 °C ea. 19765 £641.20
MXT-Msieve 5A Columns (Siltek-treated, stainless-steel PLOT)Description temp. limits qty. cat.# Price £MXT-Msieve 5A 30 m, 0.53 mm ID, 50 µm to 300 °C 7" 11-pin cage ea. 79723 £1,292.40MXT-Msieve 5A 30 m, 0.53 mm ID, 50 µm to 300 °C 3.5" Coil ea. 79723-273 £1,292.40
MXT-Q-BOND Columns (Siltek-treated, stainless-steel PLOT)Description temp. limits qty. cat.# Price £MXT-Q-BOND 30 m, 0.53 mm ID, 20 µm to 280/300 °C 7" 11-pin cage ea. 79716 £893.45MXT-Q-BOND 30 m, 0.53 mm ID, 20 µm to 280/300 °C 3.5" Coil ea. 79716-273 £893.45
Turn to Restek PLOT Columns for Reproducible ResultsRestek’s next-generation PLOT columns show a constant flow behavior and have significantly improved mechanical stability, resulting in easier operation, better chromatography, and reduced particle release. Greater particle stability also means more reproducible retention times, virtually no spiking, and longer column lifetimes.
Go to www.restek.com/PLOT for our full selection!
These and many more Restek GC columns are waiting at www.restek.com/GC6
• Optimized stationary phase selectivity ensures accurate quantification of critical cis/trans FAME isomers.
• Application-specific QC test guarantees consistent, reliable performance for AOAC 996.06 and AOCS Ce 1j-07 methods.
• Excellent sample capacity; no peak distortion means easy, accurate peak integration.
Accurate, Reliable FAMEs Analysis
highly polar phase; biscyanopropyl polysiloxane—not bondedRt-2560 Column (fused silica)
Description temp. limits qty. cat.# Price £100 m,* 0.25 mm ID, 0.20 µm 20 to 250 °C ea. 13198 £1,541.75
*Nominal length = 100 m. The actual length is 110 m, which is equivalent to the length of the previous Rt-2560 column (cat.# 13199).
Need reference standards? Search “FAME” at www.restek.com
for a full selection.
On-Demand Videos Offer 24/7 Education in Minutes
Looking to troubleshoot faster? Shave time off an analysis? Keep your instrument running longer?
The Restek Video Library is the place for you. It contains close to 100 quick-hitting videos — with more being released each month — that are targeted at specific topics we have helped actual Restek customers with. Higher lab throughput (and a job made easier) are only a click away.
Start watching at www.restek.com/videos
Keep up to date with our new videos and more: Follow us online
facebook.com/RestekThames
twitter.com/ThamesRestek
linked.com/company/restek-thames
Find more GC products to make your lab life easier at www.restek.com/GCacc 7
Easy Injection Port Maintenance with EZ Twist Top Injection Ports• Change inlet liners faster and easier.• Gas lines are attached to shell
weldment bottom to help eliminate broken gas lines.
• Gas lines don't interfere with routine maintenance.
• Two-sided design—use, flip, then use again!
• Vespel ring embedded in top and bottom surface eliminates need for a washer.
• Highly inert gold seals reduce breakdown and adsorption of active compounds, maximizing component transfer to GC column.
Reversible Flip Seal Inlet Seal—Same Cost, Extended Lifetime
Supplies and Accessories Proven to Make Your Lab Life Easier
Flexible metal tubing allows coil diameters down to 2.5" to perfectly fit the smallest spaces. Restek MXT columns are available in a variety of standard and custom configurations.
qty. cat.# Price £Injection Port Assembly Kit kit 22177 £952.70Injection Port Assembly Kit, Siltek-Treated kit 22178 £1,041.70
For Agilent 7890 GCs
2-pk. Price £ 10-pk. Price £Flip Seal Dual Vespel Ring Inlet Seal cat.# cat.#Gold-Plated 23411 £58.85 23413 £260.70Siltek-Deactivated 23412 £54.35 23414 £264.35
Flip Seal Dual Vespel Ring Inlet Seal Kit qty. cat.#Inc: gold-plated inlet seal, reducing nut adaptor, 1/16" SS nut kit 23406 £65.80
For a list of popular MXT coiling configurations and custom ordering information, visit www.restek.com/MXT-config
The Perfect Fitfor Portable, Process, and High-Temperature GC Analysis
Description qty. cat.# Price £ 5 m, 0.53 mm ID, 0.10 µm 3.5 in coil without cage ea. 70112-273 £366.85
MXT-1HT SimDist Column (Siltek-treated stainless steel) nonpolar phase
MXT-WAX Columns (Siltek-treated stainless steel)
qty. cat.# Price £Injection Port Assembly Kit kit 22735 £867.60Injection Port Assembly Kit, Siltek-Treated kit 22736 £969.15
For Agilent 6850/6890/7820 GC(for use with large canister type filter)
Description qty. cat.# Price £ 30 m, 0.53 mm ID, 1.00 µm 2.5 in coil without cage ea. 70655-274 £654.2530 m, 0.53 mm ID, 1.00 µm 4.5 in coil without cage ea. 70655-272 £654.25
Speed Up and Simplify GC
Method Development with
• Model chromatograms• Get column recommendations• Translate methods • Calculate flowsGet started at www.restek.com/ezgc-mtfc
Now in multiple languages!
Restek’s EZGC Software Suite
SilTite µ-Union Connectors
Easy installation and a permanent leak-tight connection. Deactivated metal is stable at extreme temperatures.
Universal “Y” Press-Tight Connectors
Split sample flow—perform dual-column confirmation analysis with a single injection. Split column flow to two detectors.
Questions? Contact us or your local Restek representative (www.thamesrestek.co.uk/contact-us).Restek patents and trademarks are the property of Restek Corporation. (See www.restek.com/Patents-Trademarks for full list.) Other trademarks in Restek literature or on its website are the property of their respective owners. Restek registered trademarks are registered in the U.S. and may also be registered in other countries. To unsubscribe from future Restek communi-cations or to update your preferences, visit www.restek.com/subscribe To update your status with an authorized Restek distributor or instrument channel partner, please contact them directly.
© 2020 Restek Corporation. All rights reserved. Printed in the U.S.A.
www.thamesrestek.co.uk Lit. Cat.# GNES3144-UK
Make a Strong and Lasting Connection in Your GC
Description Fits Column ID qty. cat.# PriceSilTite µ-Union Connector Kit 0.32 mm to 0.32 mm kit 23882 £107.30SilTite µ-Union Connector Kit 0.32 mm to 0.53 mm kit 23883 £107.30SilTite µ-Union Connector Kit 0.53 mm to 0.53 mm kit 23884 £107.30SilTite µ-Union Connector Kit 0.18/0.25 mm to 0.18/0.25 mm kit 23885 £107.30SilTite µ-Union Connector Kit 0.18/0.25 mm to 0.32 mm kit 23886 £107.30SilTite µ-Union Connector Kit 0.18/0.25 mm to 0.53 mm kit 23887 £107.30
Fits Column ID Color5-pk.cat.# Price £
25-pk.cat.# Price £
For 0.18/0.25 mm to 0.18/0.25 mm ID Columns
Red to Red (end codes) 22159 £69.15 22160 £252.85
For 0.18/0.25 mm to 0.32 mm ID Columns
Red to Black (end codes) 22161 £69.15 22162 £253.40
For 0.18/0.25 mm to 0.53 mm ID Columns
Red to Blue (end codes) 22163 £69.15 22164 £252.85
For 0.32 mm to 0.32 mm ID Columns
Black to Black (end codes) 22165 £69.15 22166 £252.85
For 0.32 mm to 0.53 mm ID Columns
Black to Blue (end codes) 22167 £69.15 22168 £252.85
For 0.53 mm to 0.53 mm ID Columns
Blue to Blue (end codes) 22169 £69.15 22170 £252.85
Description 5-pk. Price £ 25-pk. Price £ 100-pk. Price £Universal Press-Tight Connectors 20400 £57.30 20401 £230.15 20402 £695.80Universal Press-Tight Connectors, Deactivated 20429 £65.95 20430 £263.65 —
Universal Press-Tight Connectors, Siltek Deactivated 20480 £78.90 20449 £325.25 —
Defined PressFit Connectors
ID-specific ends for better sealability; color-coded for easy identification. Deactivated borosilicate glass.
Description ea. Price £ 3-pk. Price £Universal "Y" Press-Tight Connector 20405 £87.55 20406 £232.30Universal "Y" Press-Tight Connector, Deactivated 20405-261 £88.60 20406-261 £235.55Universal "Y" Press-Tight Connector, Siltek Deactivated 20485 £98.35 20486 £265.80
Universal Press-Tight Connectors
One connector works with 0.1–0.53 mm ID Restek columns (0.33–0.74 mm OD). Available in standard, deactivated, and Siltek- deactivated versions.