20190919 Sportsplex SuiteA IFC-Drawings...6. electric water heater. rheem 81vp20s, 20 gallon...

6

Transcript of 20190919 Sportsplex SuiteA IFC-Drawings...6. electric water heater. rheem 81vp20s, 20 gallon...

Page 1: 20190919 Sportsplex SuiteA IFC-Drawings...6. electric water heater. rheem 81vp20s, 20 gallon capacity. include and install all accessories to provide a complete functioning unit. page
Page 2: 20190919 Sportsplex SuiteA IFC-Drawings...6. electric water heater. rheem 81vp20s, 20 gallon capacity. include and install all accessories to provide a complete functioning unit. page
Page 3: 20190919 Sportsplex SuiteA IFC-Drawings...6. electric water heater. rheem 81vp20s, 20 gallon capacity. include and install all accessories to provide a complete functioning unit. page

Page � of �1 8

GENERAL NOTES 1. ALL CONSTRUCTION SHALL COMPLY WITH THE CODES REFERENCED HEREIN AND ALL

APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS HAVING JURISDICTION.

APPLICABLE CODES:

INTERNATIONAL BUILDING CODE 2012 INTERNATIONAL FIRE CODE 2012 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL PLUMBING CODE 2012 INTERNATIONAL ENERGY CONSERVATION CODE 2012 NATIONAL ELECTRIC CODE 2014 TEXAS ACCESSIBILITY STANDARDS 2012

2. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND CONSTRUCTION MATERIAL. ALL SHEETS ARE TO BE REVIEWED AND NOTES ON ANY ONE SHEET ARE TO BE APPLIED TO ALL RELATED DRAWINGS AND DETAILS.

3. GENERAL CONTRACTOR SHALL COORDINATE ALL MECHANICAL AND ELECTRICAL FLOOR AND WALL SLEEVES AND ALL MECHANICAL SHAFTS WITH MECHANICAL, PLUMBING, ELECTRICAL, STRUCTURAL AND ARCHITECTURAL DRAWINGS.

4. CONSTRUCTION OF WORK INDICATED ON THE DRAWINGS AS (N.I.C.) IS NOT INCLUDED IN THIS CONTRACT. SUBSEQUENT DRAWINGS AND SPECIFICATIONS WILL BE SUBMITTED FOR SEPARATE APPROVAL OR THIS WORK WILL BE COMPLETED BY OTHERS OUTSIDE THIS SCOPE OF WORK.

5. COORDINATE PLACEMENT OF ALL CEILING ELEMENTS WITH MECHANICAL AND ELECTRICAL. WHERE DISCREPANCIES EXIST BETWEEN DRAWINGS AND INSTALLATION, CONSULT THE ARCHITECT PRIOR TO PROCEEDING.

6. ALL FLOOR AND ROOF ELEVATIONS ARE TO TOP OF STRUCTURAL SLAB OR DECKING, U.N.O..

7. ALL SWITCHES AND CONTROLS FOR LIGHTS, HEAT, VENTILATION, WINDOW TREATMENTS, FIRE ALARMS, AND ALL SIMILAR CONTROLS OF FREQUENT OR ESSENTIAL USE SHALL BE PLACED WITHIN REACH FOR INDIVIDUALS IN WHEELCHAIRS, AS REQUIRED BY THE TEXAS ACCESSIBILITY STANDARDS.

8. PROVIDE BLOCKING AS REQUIRED FOR WALL MOUNTED ITEMS.

9. MANUFACTURE'S NAMEPLATES, TRADEMARKS, LOGOS OR THEIR IDENTIFICATION SHALL NOT BE VISIBLE IN PUBLIC AREAS.

10. CONTRACTOR SHALL FIELD VERIFY DIMENSIONS REFERENCING EXISTING ELEMENTS

11. MECHANICAL, ELECTRICAL, AND PLUMBING DESIGN IS DESIGN BUILD BY CONTRACTOR.

Page � of �4 8

DOOR AND DRAWER FRONTS: PLASTIC LAMINATE OVER PARTICLE BOARD.

HARDWARE: FABRICATOR TO PROVIDE ALUMINUM WIRE PULLS, STEEL EURO-STYLE HINGES, AND STEEL DRAWER GUIDES.

4. WINDOW SILL AND APRON. WINDOW SILL AND APRON SHALL BE 1/2 IN. SOLID WOOD, PTD. SEE TYPICAL DETAIL.

F THERMAL AND MOISTURE PROTECTION 1. SPRAY FOAM INSULATION. PROVIDE DEMILEC SEALECTION 500 OPEN CELL SPRAY FOAM

INSULATION AND DEMILIC BLAZELOCK IB4 INTUMESCENT COATING (5 MILS WET, 3 MILS DRY) OVER SPRAY FOAM INSULATION, OR EQUAL. PER DEMILEC THE ABOVE INTUMESCENT COATING MEETS THE THERMAL BARRIER OVER SPRAY FOAM INSULATION REQUIREMENT, AS REQUIRED BY 2009 IBC, SEC. 2603.4.

ROOF (UNDERSIDE OF ROOF DECK): R-40 MIN. EXTERIOR WALLS: R-20 MIN. 2. SOUND ATTENUATION BATTS. PROVIDE UNFACED BATT INSULATION, 3.5 IN THICK, AS

SHOWN ON DRAWINGS, MANUFACTURED BY OWENS CORNING OR EQUAL. INSULATION SHALL INSTALLED PER MANUFACTURERS RECOMMENDATIONS.

G DOORS AND WINDOWS 1. DOOR SCHEDULE. SEE SHEET A1.1 FOR DOOR SCHEDULE.

2. FLUSH WOOD DOORS. CENDURA SERIES, STANDARD WOOD VENEER, FACE GRADE A, SOLID CORE, NON-RATED DOOR, AS MANUFACTURED BY MASONITE DOORS, OR EQUAL. FINISH/COLOR AS SELECTED BY OWNER FROM MANUFACTURERS STANDARD. SEE DOOR SCHEDULE AND DOOR TYPE IF DOORS ARE TO RECEIVE VISION KIT.

3. ALUMINUM FRAMES. ALUMINUM DOOR AND WINDOW FRAMES FOR INTERIOR USE, RACO CLASSIC, AS MANUFACTURED BY RACO INTERIOR PRODUCTS INC. (HOUSTON, TX). INCLUDE SILENCERS. FINISH AS SELECTED BY OWNER FROM MANUFACTURERS STANDARD.

4. HARDWARE.

HARDWARE SCHEDULE. SEE SHEET A1.1 FOR HARDWARE SCHEDULE.

CONTRACTOR SHALL PROVIDE SAMPLE OF EACH HARDWARE COMPONENT TO OWNER FOR APPROVAL, PRIOR TO INSTALLATION. SAMPLES, IF NEW, MAY BE USED IN FINAL WORK.

HARDWARE FINISH SHALL MATCH AND BE SELECTED BY OWNER FROM MANUFACTURER STANDARD.

Page � of �3 8

D CARPENTRY 1. COLD FORMED METAL FRAMING.

SYSTEM COMPONENTS: MANUFACTURERS' STANDARD NON-LOAD-BEARING STEEL STUDS OF DEPTH AND HEIGHT INDICATED ON PLANS; FABRICATED FROM SHEET STEEL MINIMUM THICKNESS AS SPECIFIED BELOW (UNLESS INDICATED OTHERWISE ON THE DRAWINGS); AND HAVING A MINIMUM FLANGE WIDTH OF 1-5/8-INCH AND RETURN LIP OF 1/2-INCH. PROVIDE MANUFACTURER’S STANDARD STEEL RUNNERS (TRACKS), BLOCKING, LINTELS, CLIP ANGLES, SHOES, REINFORCEMENTS, FASTENERS, AND ACCESSORIES FOR APPLICATIONS INDICATED, AS NEEDED TO PROVIDE A COMPLETE METAL FRAMING SYSTEM. TRACKS SHALL BE DESIGNED FOR IMPOSED LOADS, BUT SHALL BE NO THINNER THAN THE GAUGE OF THE MAIN FRAMING MEMBERS.

PROVIDE STEEL VERTICAL DEFLECTION CLIPS DESIGNED SPECIFICALLY FOR ATTACHING LIGHT GAUGE FRAMING TO BUILDING STRUCTURAL MEMBERS ALLOWING FOR VERTICAL DEFLECTION OF THE STRUCTURE.

2. PROVIDE 2x6 BACKING AT BATH ACCESSORIES.

3. FIREBLOCKING IN COMBUSTIBLE CONSTRUCTION. PER 2012 IBC, SECTION 718, PROVIDE FIRE BLOCKING TO CUT OFF CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL). FIRE BLOCKING SHALL FORM AN EFFECTIVE BARRIER BETWEEN FLOORS, BETWEEN TOP STORY AND A ROOF OR ATTIC SPACE. IN ADDITION, PROVIDE FIREBLOCKING IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES, VERTICALLY AT CEILING AND FLOOR LEVELS AND HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FT.. FIREBLOCKING SHALL CONSIST OF 2 IN. NOMINAL LUMBER, BATTS OF MINERAL WOOL, OR UNFACED FIBERGLASS BATTS, AS SPECIFIED BY CODE.

E FINISH CARPENTRY

1. ALL FINISH CARPENTRY SHALL BE FABRICATED PER ARCHITECTURAL WOODWORK INSTITUTE (AWI) STANDARDS.

2. PROVIDE BLOCKING AS REQUIRED FOR WALL MOUNTED CASEWORK ITEMS.

3. SHOP-BUILT CABINETRY. REFER TO FLOOR PLANS FOR TYPE AND EXTENT OF CABINETRY. PROVIDE CUTOUTS FOR PLUMBING FIXTURES. PRIME PAINT CONTACT SURFACES OF CUT EDGES. PROVIDE FLUSH CABINET DRAWER AND DOOR FRONTS. DRAWER AND DOOR FRONTS TO BE FLUSH OVERLAY STYLE. RE. PLASTIC LAMINATE SPECIFICATION.

CABINET CONSTRUCTION: SOFTWOOD LUMBER FRAMING AND PARTICLE BOARD.

COUNTER TOP: SELF EDGED PLASTIC LAMINATE OVER PARTICLE BOARD, SQUARE INTERNAL INTERSECTION TO BACK/SIDE SPLASH.

BACK AND SIDE SPLASH: PLASTIC LAMINATE OVER PARTICLE BOARD, SQUARE INTERNAL INTERSECTIONS TO BACK/SIDE SPLASH AND TOP SURFACE.

Page � of �2 8

A GENERAL REQUIREMENTS

1. IF THERE ARE ANY QUESTIONS REGARDING THESE PLANS, CONTACT PAX CHAGNON WITH CHAGNON ARCHITECTURE PLLC AT 512.757.9127.

2. CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH AND ENSURING THAT ALL WORKMANSHIP AND/OR MATERIALS FURNISHED MEET WITH ALL APPLICABLE CITY, COUNTY, AND OTHER JURISDICTIONAL AGENCY REQUIREMENTS.

3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS ON THE JOB SITE WHICH AFFECT HIS WORK.

4. NO CHANGES TO OR VARIATIONS FROM THESE PLANS MAY BE MADE EXCEPT UPON WRITTEN INSTRUCTION FROM THE OWNER.

5. ALL MATERIALS FURNISHED SHALL BE NEW AND OF FIRST QUALITY, NO USED MATERIALS OR SECONDS WILL BE PERMITTED UNLESS BY EXPLICIT DIRECTION OF THE OWNER.

6. NO WORK SHALL BE PERFORMED OR MATERIALS FURNISHED OTHER THAN AS SHOWN ON THESE PLANS OR AUTHORIZED IN WRITING BY THE OWNER.

7. CONTRACTOR SHALL BE RESPONSIBLE FOR BEING FAMILIAR WITH AND COMPLYING WITH MANUFACTURER'S INSTRUCTIONS FOR CORRECT INSTALLATION AND USE OF ALL MATERIALS USED.

8. CONTRACTOR WILL PROVIDE TEMPORARY SANITARY FACILITIES ON THE JOB SITE BEFORE THE START OF WORK.

9. ALL STUDS AT 16 INCHES O.C. UNLESS NOTED OTHERWISE ON PLANS.

10. ALL EXTERIOR WALL FRAMING SHALL BE 2X WOOD MEMBERS AND ALL INTERIOR WALL FRAMING SHALL BE COLD FORMED METAL FRAMING, UNLESS NOTED OTHERWISE ON PLANS.

11. STRUCT. SPECS. SHALL SUPERSEDE ARCHITECTURAL SPECS. AND DRAWINGS REGARDING CONCRETE, MASONRY, ROUGH CARPENTRY, STEEL, ETC.. REPORT ALL DISCREPANCIES TO THE ARCHITECT AND THE ENGINEER.

B SITE WORK (NOT APPLICABLE)

C CONCRETE 1. SEE NOTES AND DETAILS ON STRUCTURAL SHEET S2.0 OF SHELL BUILDING DRAWINGS,

DATED ISSUE FOR CONSTRUCTION 12.05.2019.

Page � of �8 8

5. MOP BASIN. PROVIDE FIAT MSB-24 24, 24” x 24” x 10” MOULDED STONE, INTEGRAL 3” DRAIN AND STAINLESS STEEL STRAINER, OR EQUAL. INCLUDE OPTIONAL SERVICE FAUCET (830-AA), HOSE AND HOSE BRACKET (832-AA), MOP HANGER (889-CC), AND STAINLESS STEEL WALL GUARD (MSG24X24). INCLUDE AND INSTALL ALL ACCESSORIES TO PROVIDE A COMPLETE FUNCTIONING UNIT.

6. ELECTRIC WATER HEATER. RHEEM 81VP20S, 20 GALLON CAPACITY. INCLUDE AND INSTALL ALL ACCESSORIES TO PROVIDE A COMPLETE FUNCTIONING UNIT.

Page � of �7 8

4. TOILET ACCESSORIES.

FRAMED MIRROR. PROVIDE BOBRICK MODEL B-290 2448 WELDED FRAME MIRROR, OR EQUAL. FRAME SHALL BE STAINLESS STEEL WITH SATIN FINISH. ADA AND TAS COMPLIANT.

GRAB BARS. PROVIDE BOBRICK MODEL B-6806, OR EQUAL.. (2 PER ACCESSIBLE WATER CLOSET)

MOUNTING: CONCEALED, MANUFACTURER'S STANDARD FLANGES AND ANCHORAGES. CLEARANCE: 1-1/2 IN. CLEARANCE BETWEEN WALL SURFACE AND INSIDE FACE OF BAR. GRIPPING SURFACES: MANUFACTURER'S STANDARD NONSLIP TEXTURE. HEAVY-DUTY SIZE: OUTSIDE DIAMETER OF 1-1/2 IN..

TOILET TISSUE DISPENSER. PROVIDE BOBRICK MODEL B-2840, DOUBLE-ROLL DISPENSER AND UTILITY SHELF FOR SURFACE MOUNTING WITH CONCEALED ANCHORAGE, OR EQUAL. MATERIAL: STAINLESS STEEL WITH PLASTIC SPINDLE.

HAND SOAP DISPENSER. BOBRICK MODEL B-2111, CLASSIC SERIES SURFACE-MOUNTED SOAP DISPENSER, OR EQUAL. CONTAINER AND BACK SHALL BE STAINLESS STEEL WITH SATIN FINISH. MIN. CAPACITY: 32 OZ.

HAND TOWEL DISPENSER. PROVIDE BOBRICK MODEL B-262, CLASSIC SERIES SURFACE MOUNTED PAPER TOWEL DISPENSER, OR EQUAL. UNIT SHALL BE STAINLESS STEEL WITH SATIN FINISH..

SANITARY NAPKIN DISPOSAL. BOBRICK MODEL B-254, CLASSIC SERIES SURFACE-MOUNTED SANITARY NAPKIN DISPOSAL, OR EQUAL. UNIT SHALL BE STAINLESS STEEL WITH SATIN FINISH. WASTE RECEPTACLE CAPACITY: 1.2 GAL.

J PLUMBING FIXTURES 1. WATER CLOSET. PROVIDE KOHLER K-3999 HIGHLINE, OR EQUAL. FLOOR MOUNTED,

ELONGATED BOWEL, TRIP LEVER TO BE ON OPEN SIDE OF TANK, AWAY FROM WALL. WHITE HEAVY DUTY MOLDED COLID PLASTIC ELONGATED SEAT WITH OPEN FRONT - BEMIS 1955SSC. INCLUDE AND INSTALL ALL ACCESSORIES TO PROVIDE A COMPLETE FUNCTIONING UNIT.

2. LAVATORY. PROVIDE KOHLER K2005 KINGSTON, 12”X18”, WALL HUNG WITH SINGLE CENTER HOLE FOR FAUCET, OR EQUAL. WADE W520-D FLOOR MOUNTED CARRIER WITH CONCEALED ARMS ONLY, WALL BRACKET WILL NOT BE ACCEPTABLE. INCLUDE AND INSTALL ALL ACCESSORIES TO PROVIDE A COMPLETE FUNCTIONING UNIT. PROVIDE DRAIN AND SUPPLY LINE INSULATION AS REQUIRED BY TEXAS ACCESSIBILITY STANDARDS.

3. LAVATORY FAUCET. SLOAN MODEL SF-2450, OR EQUAL. ELECTRONIC SENSOR ACTIVATED HAND WASHING FAUCET WITH BATTERY POWERED INFRARED SENSOR WITH ADJUSTABLE RANGE. INCLUDE AND INSTALL ALL ACCESSORIES TO PROVIDE A COMPLETE FUNCTIONING UNIT.

4. SINK AND FAUCET KIT. DAYTON STAINLESS STEEL 33”x22”x6 1/2” EQUAL DOUBLE BOWL DROP-IN SINK AND FAUCET KIT. MODEL K233224DF OR EQUAL. ***FAUCET CONTROLS AND BOWL DEPTH/KNEE SPACE MUST BE ADA/TAS COMPLIANT***. PROVIDE DRAIN AND SUPPLY LINE INSULATION AS REQUIRED BY TEXAS ACCESSIBILITY STANDARDS.

Page � of �6 8

8. PLASTIC LAMINATE. PROVIDE HIGH PRESSURE LAMINATE AS MANUFACTURED BY FORMICA GROUP OR EQUAL. PROVIDE (1) COUNTERTOP AND SPLASH COLOR AND (1) CABINET COLOR. COLORS SHALL BE SELECTED BY OWNER FROM MANUFACTURER’S STANDARD.

9. WOOD CEILING. PROVIDE 1”x6” TONGUE AND GROOVE (V-GROOVE), SOUTHERN YELLOW PINE.

10. RUBBER WALL BASE. RUBBER WALL BASE AS MANUFACTURED BY ROPPE CORPORATION, USA, OR EQUAL. RUBBER WALL BASE SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS ON ALL INTERIOR WALLS WITH GYPSUM WALL BOARD AS THE EXPOSED FINISH MATERIAL. COLOR AS SELECTED BY OWNER FROM MANUFACTURER'S STANDARD PALLET.

11. ACOUSTIC CEILING TILE AND GRID SYSTEM (ACT). PROVIDE ACOUSTIC CEILING TILE AS SHOWN ON DRAWINGS, AS MANUFACTURED BY ARMSTRONG WORLD INDUSTRIES, INC., OR EQUAL.

TILE: PROVIDE ARMSTRONG 24"X24"X5/8" FINE FISSURED #1728.

GRID: ARMSTRONG PRELUDE ML, 5/16" EXPOSED TEE SYSTEM.

12. PAINT SCHEDULE:

COLOR MOCKUP TO BE APPLIED TO PORTION OF BUILDING TO ILLUSTRATE COLOR ON EACH INTERIOR MATERIAL TO BE PAINTED. COLOR MOCKUP SHALL BE REVIEWED AND APPROVED BY OWNER PRIOR TO FURTHER COLOR PAINT APPLICATION. APPROVED COLOR MOCKUP MAY REMAIN AS FINAL WORK.

PT-1 GYPSUM WALL BOARD. PRIMER: SHERWIN-WILLIAMS PROPMAR 200 INTERIOR LATEX PRIMER. FINISH: SHERWIN-WILLIAMS PROPMAR 200 INTERIOR LATEX, SEMI-GLOSS. COLOR AS SELECTED BY OWNER.

STN-1 WOOD CEILING. FINISH: SHERWIN-WILLIAMS, SUPER DECK, WATER BASED, SEMI-TRANSPARENT.

COLOR AS SELECTED BY OWNER. (WHITE WASH OR GRAY WASH)

13. PROVIDE TO OWNER EXTRA MATERIALS EQUAL TO ONE PERCENT OF TOTAL UNIT AREA FOR EACH MATERIAL UPON COMPLETION OF THE PROJECT.

I SPECIALTY 1. SIGNAGE. PROVIDE TOILET ROOM WITH RESTROOM ACCESSIBILITY SIGN. SEE T.A.S.

INTERIORS SHEET FOR MOUNTING LOCATIONS. ALL SIGNS SHALL COMPLY WITH CHARACTER PROPORTION AND HEIGHT, RAISED AND BRAILLE CHARACTERS AND PICTORIAL SYMBOL SIGNS, FINISH AND CONTRAST, MOUNTING LOCATION AND HEIGHT, AND SYMBOLS OF ACCESSIBILITY REQUIREMENTS AS DEFINED BY TEXAS ACCESSIBILITY STANDARDS. SIGN COLOR AS SELECTED BY OWNER FROM MANUFACTURERS STANDARD PALLET. ROOM TITLES TO BE VERIFIED BY OWNER.

2. PORTABLE FIRE EXTINGUISHERS. PROVIDE MULTIPURPOSE DRY-CHEMICAL TYPE: UL-RATED 2A-10B:C, 10-LB NOMINAL CAPACITY, WITH MONOAMMONIUM PHOSPHATE-BASED DRY CHEMICAL IN MANUFACTURER'S STANDARD ENAMELED CONTAINER

3. FIRE EXTINGUISHER CABINETS. PROVIDE SEMI-RECESSED STEEL, WHITE WITH RED LETTERING,. CONTRACTOR TO COORDINATE TYPE AND CAPACITY OF FIRE EXTINGUISHER WITH FIRE EXTINGUISHER CABINETS TO ENSURE FIT AND FUNCTION. MOUNTING HEIGHT AND PROJECTION FROM WALL SHALL COMPLY WITH TEXAS ACCESSIBILITY STANDARDS.

Page � of �5 8

5. GLAZING.

ALL NEW GLAZING MATERIALS USED IN WINDOWS AND DOORS SHALL BE CERTIFIED BY THE MANUFACTURER TO COMPLY WITH THE SAFETY STANDARD FOR ARCHITECTURAL GLAZING MATERIALS CHAPTER 24 OF THE 2012 INTERNATIONAL BUILDING CODE WHENEVER APPLICABLE. GLASS TYPES, AS MANUFACTURED BY PPG INDUSTRIES, INC, OR EQUAL.

M-A MONOLITHIC, FULLY TEMPERED. (INTERIOR WINDOWS AND DOORS) 1. PRODUCT: 1/4 INCH THICK, CLEAR.

H FINISHES

1. ROOM FINISH SCHEDULE. SEE SHEET A1.1 FOR ROOM FINISH SCHEDULE.

2. CONCRETE STAIN. PROVIDE ACID STAIN WHICH COLORS CONCRETE SURFACES WITH A TRANSLUCENT APPEARANCE. MOCKUP SHALL BE REVIEWED AND APPROVED BY OWNER PRIOR TO FURTHER MATERIAL APPLICATION. APPROVED COLOR MOCKUP MAY REMAIN AS FINAL WORK.

3. CONCRETE SEALER. PROVIDE COMMERCIAL GRADE CONCRETE SEALER. INSTALL PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR TO VERIFY COMPLIANCE WITH CONCRETE STAIN MANUFACTURER’S RECOMMENDATIONS.

4. GYPSUM WALL BOARD. PROVIDE 5/8 IN. GYPSUM WALL BOARD AS MANUFACTURED BY GEORGIA-PACIFIC, OR EQUAL.

FINISH. LEVEL 4.

TEXTURE. LIGHT ORANGE PEEL.

CORNERS BEADS. SQUARE (NOT ROUNDED).

ANCHORING. ANCHORING SHALL BE AS FOLLOWS EXCEPT WHERE INDICATED OTHERWISE ON PLANS. APPLIED TO VERTICAL FRAMING MEMBERS: (ALL WALL PARTITIONS) (1) 5/8" GYPSUM WALL BOARD WITH 1- 1/4" SCREWS @ 8" O.C. NOT MORE THAN 3/8" FROM EDGES AND ENDS AND 1- 1/4" SCREWS AT 8" O.C. AT FIELD. PROVIDE 5/8" MOISTURE-RESISTANT GYPSUM WALL BOARD AT MEN'S RESTROOM, WOMEN'S RESTROOM, AND AT WATER FOUNTAIN.

5. WALL TILE. GLAZED CERAMIC WALL TILE, SEMI-GLOSS, AS MANUFACTURED BY DALTILE CORPORATION. PROVIDE 3x6 WALL TILE (FIELD TILE) AS SHOWN ON DRAWINGS. COLOR: TO BE SELECTED BY OWNER FROM PRICE GROUP 1 COLOR PALLET.

6. TILE GROUT. PROVIDE LATEX-PORTLAND CEMENT TILE GROUT, AS MANUFACTURED BY C-CURE CHEMICAL COMPANY, INC., OR EQUAL. PROVIDE SEALANT FOR GROUT AS RECOMMENDED BY GROUT MANUFACTURER. COLOR TO BE SELECTED BY OWNER FROM MANUFACTURERS STANDARD COLOR PALLET.

7. TILE EDGE PROFILE. PROVIDE METAL EDGE PROFILE AS MANUFACTURED BY SCHLUTER SYSTEMS, OR EQUAL, AS SHOWN ON DRAWINGS. MODEL: JOLLY. FINISH: ANODIZED ALUMINUM, SATIN (AE).

Page 4: 20190919 Sportsplex SuiteA IFC-Drawings...6. electric water heater. rheem 81vp20s, 20 gallon capacity. include and install all accessories to provide a complete functioning unit. page

1. ALL WORK DONE UNDER THIS SECTION SHALL COMPLY WITH THE 2014 NATIONAL ELECTRICAL CODE AND LOCAL CODE REGULATIONS. THE CONTRACTOR SHALL PERFORM ALL WORK IN CONFORMITY WITH THESE REGULATIONS WHETHER OR NOT SUCH WORK IS SPECIFICALLY SHOWN ON DRAWINGS.

2. VERIFY LOCATION OF & TYPE OF POWER TO ALL EQUIPMENT AND APPLIANCES.

3. GANG ALL SWITCHES AND OUTLETS WHERE POSSIBLE.

4. GROUND FAULT CIRCUIT INTERRUPTER OUTLETS WITHIN 36" OF A SINK OR LAVATORY TO BE ON A G.F.I. CIRCUIT. ADDITIONAL G.F.I. AS REQUIRED BY CODE.

5. HEIGHT OF OUTLETS FROM FLOOR TO CENTER LINE OF OUTLET TO BE 18" TYPICAL UNLESS NOTED OTHERWISE. RE. T.A.S. INTERIORS SHEET.

6. HEIGHT OF SWITCHES AND T-STAT FROM FLOOR TO CENTER LINE OF SWITCH OR T-STAT TO BE 45" TYPICAL UNLESS NOTED OTHERWISE. RE. T.A.S. INTERIORS SHEET.

7. SUPPLY 220v & 110v OR GAS & 110v TO HVAC UNIT(S). PROVIDE POWER AS REQ'D. AT A/C COMPRESSOR UNITS.

8. ALL EXTERIOR OUTLETS AND SWITCHES TO BE WATERPROOF, NOTED OR OTHERWISE.

9. LEGEND.

ELECTRICAL PANEL

ARC FAULT INTERRUPTERDUPLEX RECEPTACLE. RE.GROUND FAULT CIRCUITINTERRUPTER, SEE NOTES ABOVE.'WP' DESIGNATES WATERPROOF RECEPTACLE.

220 SINGLE RECEPTACLE

DATA / VOICE RECEPTACLE

TELEVISION / DATA RECEPTACLE

FLOOR PLAN NOTES

NOTES:

1. ALL CONSTRUCTION SHALL ADHERE TO THE REQUIREMENTS OF THE 2012 INTERNATIONAL BUILDING CODE, 2012 TEXAS ACCESSIBILITY STANDARDS, AND ALL OTHER LOCAL CODES AND ORDINANCES.

2. REFER TO ADA-TAS INTERIORS SHEET FOR REQUIRED CLEARANCES AND INTERIOR MOUNTING HEIGHTS.

3. REFER TO ROOF FINISH, WINDOW, DOOR, AND HARDWARE SCHEDULES ON SHEET A1.1.

4. MECHANICAL, ELECTRICAL, AND PLUMBING DESIGN IS DESIGN BUILD BY CONTRACTOR.

5. ALL DIMENSIONS REFERENCE FACE OF STUD.

6. ALL INTERIOR WALLS TO BE AS SCHEDULED. RE. WALL TYPE SCHEDULE.

7. DOOR OPENINGS THAT ARE NOT DIMENSIONALLY LOCATED ARE TO BE CENTERED BETWEEN WALLS OR POSITIONED WITH THE JAMB 4 IN. FROM AN ADJACENT WALL OR COLUMN AS SHOWN ON THE PLANS.

8. ALL WINDOWS WILL BE DIMENSIONED TO CENTER LINE UNLESS OTHERWISE NOTED.

9. GENERAL CONTRACTOR TO VERIFY SIZING AND LOCATION OF ALL APPLIANCES & RELATED COMPONENTS.

10. ALL PLUMBING, APPLIANCE AND GAS VENTS TO VENT TO REAR OF ROOF RIDGE WHEREVER POSSIBLE.

POWER PLAN NOTES

A EXTERIOR WALL. EXTERIOR WALL. PROVIDE SPRAY FOAM INSULATION IN WALL CAVITY, AS SPECIFIED, WITH ONE LAYER 5/8" G.W.B., FULL HEIGHT OF WALL (FOR FIREBLOCKING PURPOSE), AT INTERIOR SIDE. INCLUDE 2x WD. FIRE BLOCKING AT 10 FT. A.F.F..

B 6" 25 GA. METAL STUDS @ 16" O.C. WITH FULLHEIGHT SOUND ATTENUATION BATTS AND WITH ONE LAYER 5/8" GYP. BOARD AT TENANT FINNISH-OUT SIDE. EXTEND WALL TO BOTTOM SIDE OF ROOF DECK.

C 3 5/8" 25 GA. METAL STUDS @ 16" O.C. WITH FULLHEIGHT SOUND ATTENUATION BATTS AND WITH ONELAYER 5/8" GYP. BOARD EACH SIDE. EXTENDWALL 1'-0" ABOVE CEILING LINE (MIN.).

EXISTING WALL TO REMAIN

PROPOSED WALL

NOTES:

1. TYP. INT. WALL SECTION DETAILS, RE. 2 & 3/A1.0. 2. ALL WALLS NOT KEYED ARE TO BE TYPE 'C'.

3. PROVIDE 5/8" THICK MOISTURE-RESISTANT GYPSUM WALL BOARD, AS SPECIFIED, AT ALL WALLS SCHEDULED TO RECEIVE WALL TILE.

WALL TYPES SCHEDULE

C1 SAME AS 'C' WITH NO SOUND ATTENUATION BATTS.

D 6" 25 GA. METAL STUDS @ 16" O.C. WITH FULL HEIGHT SOUND ATTENUATION BATTS AND WITH ONE LAYER 5/8" GYP. BOARD EACH SIDE. EXTEND WALL 1'-0" ABOVE CEILING LINE (MIN.).

D1 SAME AS 'D' WITH NO SOUND ATTENUATION BATTS.

103A

002A

101A

102A

A

104A

006A

007A

005C

005B

005A

004B 004A

ROOM002

OFFICE101

CONFERENCE

OFFICE103

OFFICE104

COPY004

HALL003

MEN006

RECEPTION001

BREAK005

WOMEN007

30" S

INK

W/ K

NE

ES

PA

CE

36"

REF

.

18"

UTI

L.C

AB

.

MOPSINK

1R/1

S

OFFICE102

SH

ELV

S

HVACCOND.UNIT

W.P.220

ELE

C.

PA

NE

L

DAT

A /

VO

ICE

DAT

A /

VO

ICE

DATA /VOICE

DAT

A /

VO

ICE

DAT

A /

VO

ICE

TV/D

ATA

66" 66

"

FLOORPOWER & TV/DATA

DAT

A /

VO

ICE

DATA /VOICE

42"

42"

42"

45"

45"

18'-4

"16

'-0"

10'-5

"

11'-6" 11'-6" 11'-4"

34'-4"

EQ

.E

Q.

ALIGN

2'-3" 5'-3" 2'-4" 7'-6" 5'-2"

8'-0

"8'

-0"

5'-6

"

5'-4

"5'

-4"

5'-4

"

44'-9

" (E

XIS

TIN

G)

21'-9

"

ALIGN

ALIGN

A

A

A

A

A

AB

D

D

D1

D1

5'-1

0 1/

2"

48" P

HO

TOC

OP

IER

SHELVS 1'-1

0"DATAPANEL42"

SH

ELV

S

F.E

.C.

ALIGN

4'-11" 4'-11"

10'-5

"2'

-1 1

/2"

11'-0

"

EXISTING CONCRETEGRADE BEAM

60"

REF.

001A

CHAGNON

arc

hit

ec

ture

. i

nte

rio

rs .

de

sig

n-b

uil

d

215

W. S

AN

AN

TON

IO S

T., S

UIT

E 2

104,

SA

N M

AR

CO

S, T

EX

AS

786

66

5

1 2

. 7 5

7 .

9 1

2 7

ww

w.c

hagn

onar

ch.c

om

pcha

gnon

@ch

agno

narc

h.co

m

SHEET NUMBER

REV

.

D

ES

CR

IPTI

ON

DAT

E

2019

ALL

DR

AW

ING

S A

ND

DO

CU

ME

NTS

, AS

INS

TRU

ME

NTS

OF

SE

RV

ICE

, RE

MA

IN T

HE

PR

OP

ER

TY O

F C

HA

GN

ON

AR

CH

ITE

CTU

RE

, PLL

C.

THE

US

E O

R R

EP

RO

DU

CTI

ON

OF

THE

SE

DR

AW

ING

S F

OR

CO

NS

TRU

CTI

ON

OTH

ER

TH

AN

TH

AT W

HIC

H IS

DE

SC

RIB

ED

HE

RE

IN, I

S P

RO

HIB

ITE

D W

ITH

OU

T W

RIT

TEN

CO

NS

EN

T O

F C

HA

GN

ON

AR

CH

ITE

CTU

RE

, PLL

C.

c

SP

OR

TSP

LEX

OFF

ICE

BU

IDLI

NG

- S

UIT

E A

249

SP

OR

TSP

LEX

DR

., D

RIP

PIN

G S

PR

ING

S, T

EX

AS

7862

0

ISS

UE

FO

R C

ON

STR

UC

TIO

N

09.

19.2

019

FLOOR PLAN

A1.0

METAL TOP TRACKWITH 2" DEEP LEGS

ACOUSTIC CEILING TILE AND GRID SYSTEM

CONCRETE FOUNDATION FINISH FLOOR AS SCHEDULED

WALL BASE

5/8" GYPSUM WALL BOARD EACH SIDE

COLD FORMED METAL STUDS

FIBERGLASS BATT INSULATION,AS SPECIFIED, RE. WALL TYPESCHEDULE

METAL BOTTOM TRACK

RE

. RE

FLE

CTE

D C

EIL

ING

PLA

N

METAL TOP TRACKWITH 2" DEEP LEGS

EXISTING ROOF DECK

ACOUSTIC CEILING TILE AND GRID SYSTEM

CONCRETE FOUNDATION FINISH FLOOR AS SCHEDULED

WALL BASE

5/8" GYPSUM WALL BOARD AT TENNENT SIDE

COLD FORMED METAL STUDS

FIBERGLASS BATT INSULATION,AS SPECIFIED, RE. WALL TYPESCHEDULE

METAL BOTTOM TRACK

RE

. RE

FLE

CTE

D C

EIL

ING

PLA

N

TOP OF STUDS CUT 1" LESS THAN ASSEMBLY HEIGHT, WITH DEFLECTION CLIPS

TENANT FINISH-OUT

UNFINISHED

TOP OF STUDS CUT 1" LESS THAN ASSEMBLY HEIGHT, WITH DEFLECTION CLIPS

EXISTING BOTTOM CORD OF WD. TRUSS

DRAFTSTOPPING NOTE:

PER 2012 IBC, SEC. 718.4, IN COMBUSTIBLE CONSTRUCTION, DRAFTSTOPPING SHALL BE INSTALLED TO SUBDIVIDE ATTIC SPACES AND CONCEALED ROOF SPACES.

PER SEC. 718.4.3, DRAFTSTOPPING SHALL BE INSTALLED IN ATTICS AND CONCEALED ROOF SPACES, SUCH THAT ANY HORIZONTAL AREA DOES NOT EXCEED 3,000 S.F.

PER SEC. 718.3.1, DRAFTSTOPING MATERIALS SHALL NOT BE LESS THAN 1/2" GYPSUM BOARD (OTHER MATERIAL OPTIONS NOTED IN CODE).

DOOR TYPE 1

RE

. DO

OR

SC

HE

DU

LE

RE. DOOR SCHEDULE

WINDOW TYPE A

2"2"

2"5'

-9"

2'-9

"

9'-0

"

2" 2" 2"EQ.

9'-0"

2" EQ.EQ.

TEMP.GLASS(M-A)

TEMP.GLASS(M-A)

TEMP.GLASS(M-A)

TEMP.GLASS(M-A)

TEMP.GLASS(M-A)

TEMP.GLASS(M-A)

DOOR

FLOOR PLAN1/4" = 1'-0"1TYPICAL INTERIOR WALL SECTION

3/4" = 1'-0"2

WALL SECTION SEPERATING TENANTS3/4" = 1'-0"3

INTERIOR DOOR AND WINDOW TYPES3/8" = 1'-0"4

Page 5: 20190919 Sportsplex SuiteA IFC-Drawings...6. electric water heater. rheem 81vp20s, 20 gallon capacity. include and install all accessories to provide a complete functioning unit. page

OS

A

A

A

A

AOS

OS

A

OS

AAOS

A

OS

E

OSA

EM

E

OS

AEM

EX

BEMB B

B

BB

EM

EX

EX, WALL MOUNT

AEM

OS

OS

OS

R R

RR

A

A

RR

AEM

EM

OS

B

OS

CEILING(B.O. TRUSS)13'-6" A.F.F.

CHAGNON

arc

hit

ec

ture

. i

nte

rio

rs .

de

sig

n-b

uil

d

215

W. S

AN

AN

TON

IO S

T., S

UIT

E 2

104,

SA

N M

AR

CO

S, T

EX

AS

786

66

5

1 2

. 7 5

7 .

9 1

2 7

ww

w.c

hagn

onar

ch.c

om

pcha

gnon

@ch

agno

narc

h.co

m

SHEET NUMBER

REV

.

D

ES

CR

IPTI

ON

DAT

E

2019

ALL

DR

AW

ING

S A

ND

DO

CU

ME

NTS

, AS

INS

TRU

ME

NTS

OF

SE

RV

ICE

, RE

MA

IN T

HE

PR

OP

ER

TY O

F C

HA

GN

ON

AR

CH

ITE

CTU

RE

, PLL

C.

THE

US

E O

R R

EP

RO

DU

CTI

ON

OF

THE

SE

DR

AW

ING

S F

OR

CO

NS

TRU

CTI

ON

OTH

ER

TH

AN

TH

AT W

HIC

H IS

DE

SC

RIB

ED

HE

RE

IN, I

S P

RO

HIB

ITE

D W

ITH

OU

T W

RIT

TEN

CO

NS

EN

T O

F C

HA

GN

ON

AR

CH

ITE

CTU

RE

, PLL

C.

c

SP

OR

TSP

LEX

OFF

ICE

BU

IDLI

NG

- S

UIT

E A

249

SP

OR

TSP

LEX

DR

., D

RIP

PIN

G S

PR

ING

S, T

EX

AS

7862

0

ISS

UE

FO

R C

ON

STR

UC

TIO

N

09.

19.2

019

REFLECTEDCEILING PLAN

A1.1

REFLECTED CEILING PLAN1/4" = 1'-0"1

NOTES:

1. MECHANICAL, ELECTRICAL, AND PLUMBING DESIGN IS DESIGN BUILD BY CONTRACTOR.

2. FIRE ALARM AND DETECTION SYSTEM. CONTRACTOR SHALL DESIGN AND INSTALL A COMPLETE FIRE ALARM AND DETECTION SYSTEM PER 2012 INTERNATIONAL FIRE CODE, NFPA 72, AND LOCAL CODE ORDINANCES.

3. ALL LIGHT FIXTURES AND BULBS SHALL BE LED.

4. ALL EXTERIOR OUTLETS AND SWITCHES TO BE WATERPROOF, NOTED OR OTHERWISE.

5. ALL CEILINGS AT 11'-0" A.F.F. UNLESS NOTED OTHERWISE.

6. HEIGHT OF SWITCHES AND T-STAT FROM FLOOR TO CENTER LINE OF SWITCH OR T-STAT TO BE 45" TYPICAL UNLESS NOTED OTHERWISE. RE. T.A.S. INTERIORS SHEET.

LEGEND:

2x2 ACOUSTICAL CEILING TILE AND GRID SYSTEM.

1x6 WOOD CEILING

2x4 RECESSED LED TROFFER'EM' = PROVIDE BATTER BACK UP.

2x2 RECESSED LED TROFFER'EM' = PROVIDE BATTER BACK UP.

6 IN. RECESSED DOWN LIGHT FIXTURE'EM' = PROVIDE BATTER BACK UP.

SURFACE MOUNTED DOWN LIGHT FIXTURE, FULLY SHIELDED,

'EM' = PROVIDE BATTER BACK UP.

B

A

D

C

EXIT LIGHT FIXTURE.

HVAC SUPPLY.

HVAC RETURN.

EXHAUST FAN.

SWITCH. 'OS' DESIGNATES SWITCHWITH INTEGRATED OCCUPANCYSENSOR TO MEET 2012 IECC

REQUIREMENTS. IF OMITTED, LIGHT REDUCTION CONTROLS ARE REQUIRED.

EX

E

OS

MANUFACTURER LEGEND:

1. (BYO) BY OTHERS

2. (DLR) HARDWARE SUPPLIER

3. (GLY) GLYNN JOHNSON

4. (IVE) IVES

5. (LCN) LCN

6. (NGP) NATIONAL GUARD PRODUCTS

7. (SCH) SCHLAGE

8. (TBD) TO BE DETERMINED

HARDWARE SCHEDULE NOTES:1. GENERAL CONTRACTOR SHALL COORDINATE

COMPATIBILITY OF EXTERIOR DOOR HARDWARE WITH OWNER/TENANT'S SECURITY ACCESS SYSTEM PROVIDER. VERIFY WITH OWNER/TENANT.

2. CONTRACTOR SHALL PROVIDE SAMPLE OF EACH HARDWARE COMPONENT TO OWNER/TENANT FOR APPROVAL, PRIOR TO INSTALLATION. SAMPLES, IF NEW, MAY BE USED IN FINAL WORK.

HARDWARE SCHEDULE

HARDWARE SCHEDULE:

HW SET: 01 (OFFICES & CONFERENCE)EACH TO HAVE:3 EA HINGE 3CB1 4.5 X 4.5 (IVE)1 EA ENTRANCE/OFFICE LOCK, AL50PD, SATURN LEVER (SCH)

PUSH-BUTTON LOCKING. PUSH-BUTTON LOCKS OUTSIDE LEVER UNTIL UNLOCKED WITH KEY OR BY ROTATING INSIDE LEVER.

1 EA WALL STOP WS406CCV (IVE)3 EA SILENCERS SR64 (IVE)

HW SET: 02 (TOILET ROOMS)EACH TO HAVE:3 EA HINGE 3CB1 4.5 X 4.5 (IVE)1 EA BATH PRIVACY LOCK, AL40S, SATURN LEVER (SCH)

PUSH-BUTTON LOCKING. CAN BE OPENED FROM OUTSIDE WITH SMALL SCREWDRIVER.

1 EA WALL STOP WS406CCV (IVE)3 EA SILENCERS SR64 (IVE)

3. HARDWARE FINISH SHALL MATCH AND BE SELECTED BY OWNER/TENANT FROM MANUFACTURER STANDARD.

4. ALL LOCK SETS SHALL BE ADA COMPLIANT, DOOR KNOBS ARE NOT PERMITTED.

5. PER IBC SEC. 1008.1.9.4, BOLT LOCKS (DEAD BOLTS) ARE NOT PERMITTED.

6. PER IBC SEC. 1008.1.9, DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.

HW SET: 03 (CLOSET DOORS)EACH TO HAVE:3 EA HINGE 3CB1 4.5 X 4.5 (IVE)1 EA PASSAGE LOCK, AL10S, SATURN LEVER (SCH)

BOTH LEVERS ALWAYS UNLOCKED.1 EA WALL STOP WS406CCV (IVE)3 EA SILENCERS SR64 (IVE)

FINISH SCHEDULE KEY:CONC. - CONCRETE FLOOR FINISH

(RE. STAIN AND SEALER SPECIFICATION)

V.C.T. - VINYL COMPOSITE TILEV.S.F. - VINYL SHEET FLOORINGR.B. - RUBBER BASE

NO. ROOM NAME WALLS/FINISH CEILING/FINISHWALL BASE001 RECEPTION WOOD/STND.

& A.C.T. RB.CONC.

002 CONC. G.W.B./PTD. RB.

ROOM FINISH SCHEDULE

A.C.T. CONFERENCE

003 HALL A.C.T. RB.CONC.

004 CONC. G.W.B./PTD.RB. A.C.T. COPY

G.W.B./PTD. & WOOD WALL PANELING/STND.

005 CONC. RB. A.C.T. BREAK

006 CONC. RB. A.C.T. MEN

007 CONC. RB. A.C.T. WOMEN

101 CONC. RB. A.C.T. OFFICE

G.W.B./PTD. & TILE

G.W.B./PTD.

G.W.B./PTD. & TILE

G.W.B./PTD. & TILE

102 CONC. RB. A.C.T. OFFICE G.W.B./PTD.

103 CONC. RB. A.C.T. OFFICE G.W.B./PTD.

104 CONC. RB. A.C.T. OFFICE G.W.B./PTD.

FLOOR

G.W.B./PTD.

TILE - CERAMIC WALL TILEGWB. - GYPSUM WALL BOARDPTD. - PAINTEDF.R.P. - FIBERGLAS REINFORCED PANELA.C.T. - ACOUSTIC CEILING TILE

AND GRID SYSTEM

DOOR SCHEDULE

NO. SIZE DOOR FRAME HDWR. DOOR TYPEMATERIAL FINISH MATERIAL FINISH

001A EXISTING DOOR002A 3'-0" x 7'-0" SC PRE-FINISH ALUM - 1 1004A 3'-0" x 7'-0" SC PRE-FINISH ALUM - 3 1004B 3'-0" x 7'-0" SC PRE-FINISH ALUM - 3 1005A 3'-0" x 7'-0" SC PRE-FINISH ALUM - 3 1005B 3'-0" x 7'-0" SC PRE-FINISH ALUM - 3 1005C 3'-0" x 7'-0" SC PRE-FINISH ALUM - 3 1006C 3'-0" x 7'-0" SC PRE-FINISH ALUM - 2 1007C 3'-0" x 7'-0" SC PRE-FINISH ALUM - 2 1

101A 3'-0" x 7'-0" SC PRE-FINISH ALUM - 1 1102A 3'-0" x 7'-0" SC PRE-FINISH ALUM - 1 1103A 3'-0" x 7'-0" SC PRE-FINISH ALUM - 1 1104A 3'-0" x 7'-0" SC PRE-FINISH ALUM - 1 1

MATERIALS KEY:ALUM - ALUMINUMHM - HOLLOW METALSC - SOLID CORE FLUSH WOOD DOORPRE-FINISH - PRE-FINISHED / FACTORY FINISHEDPTD - PAINTEDWD - WOODSF - STEEL FRAME

WINDOW SCHEDULETYPE SIZE GLAZING NOTESA 9'-0" x 9'-0" - 9'-0" H.H. M-A SEE 4/A1.0, INTERIOR WINDOW

NOTE:1.0 - ALL INTERIOR DOORS TO BE UNDERCUT 3/4" FOR AIR SUPPLY.

R.C.P. NOTES

Page 6: 20190919 Sportsplex SuiteA IFC-Drawings...6. electric water heater. rheem 81vp20s, 20 gallon capacity. include and install all accessories to provide a complete functioning unit. page

24

1 1/

2"

2'-1

0"

SE

E E

LEVA

TIO

N

COUNTERTOP AND BACK SPLASH, AS SPECIFIED

ADA SINK, AS SCHEDULED

INSULATE DRAIN PIPE AND HOT WATER SUPPLY PER TAS REQUIREMENTS

2'-3

" MIN

.

6" MAX. 8" MIN.

9" M

IN.

SINK/COUNTER TOPSECTION DETAIL

KNEE AND TOE CLEARANCE PER TAS REQUIREMENTS, RE. ADA-TAS INTERIORS SHEET

1x6 APRON BOARD

WOMENSCALE: 1/2" = 1'1WOMEN

SCALE: 1/2" = 1'2WOMEN SCALE: 1/2" = 1'4 WOMEN

SCALE: 1/2" = 1'3

NOTE:RE. ADA-TAS INTERIORS SHEET FOR FIXTURE AND ACCESSORY MOUNTING HEIGHTS AND DIMENSIONS.

HAND TOWAL DISPENSER, AS SPECIFIED

WALL TILE, AS SPECIFIED

GYPSUM WALL BOARD, AS SPECIFIED

TILE EDGE PROFILE, AS SPECIFIED

DOOR, HARDWARE, AND FRAME, AS SPECIFIED

3'-6

"

BREAK & COPYSCALE: 1/2" = 1'9

GRAB BARS, AS SPECIFIED

WATER CLOSET, ASSPECIFIED

WALL TILE, AS SPECIFIED

GYPSUM WALL BOARD,AS SPECIFIED

HAND TOWAL DISPENSER,AS SPECIFIED

FRAMED MIRROR,AS SPECIFIED

HAND SOAP DISPENSER,AS SPECIFIED

LAVATORY W/ FLOORMOUNTED CARRIER IN

WALL, AS SPECIFIED

TILE EDGE PROFILE, ASSPECIFIED

3'-6

"

3'-6

"

WALL TILE, AS SPECIFIED

GYPSUM WALL BOARD, AS SPECIFIED

TILE EDGE PROFILE, AS SPECIFIED

3'-6

"WALL TILE, AS SPECIFIED

GYPSUM WALL BOARD,AS SPECIFIED

TILE EDGE PROFILE,AS SPECIFIED

DOOR, HARDWARE, ANDFRAME, AS SPECIFIED

MEN SCALE: 1/2" = 1'5MEN

SCALE: 1/2" = 1'6MEN SCALE: 1/2" = 1'7

GRAB BARS, AS SPECIFIED

WALL TILE, AS SPECIFIED

GYPSUM WALL BOARD,AS SPECIFIED

TILE EDGE PROFILE,AS SPECIFIED

MEN SCALE: 1/2" = 1'8

3'-6

"

3'-6

"

WALL TILE, AS SPECIFIED

GYPSUM WALL BOARD, AS SPECIFIED

TILE EDGE PROFILE, AS SPECIFIED

3'-6

"

GRAB BARS, AS SPECIFIED

WATER CLOSET, AS SPECIFIED

TOILET TISSUE DISPENSER, AS SPECIFIED

WALL TILE, AS SPECIFIED

GYPSUM WALL BOARD, AS SPECIFIED

TILE EDGE PROFILE, AS SPECIFIED

WATER CLOSET, ASSPECIFIED

TOILET TISSUE DISPENSER,AS SPECIFIED

SANITARY NAPKIN DISPOSAL,AS SPECIFIED

4'-0

"

GRAB BARS, AS SPECIFIED

WATER CLOSET, AS SPECIFIED

WALL TILE, AS SPECIFIED

GYPSUM WALL BOARD, AS SPECIFIED

CL

2'-0"

FRAMED MIRROR, AS SPECIFIED

HAND SOAP DISPENSER, AS SPECIFIED

3'-3

"

LAVATORY W/ FLOOR MOUNTED CARRIER IN WALL, AS SPECIFIED

TILE EDGE PROFILE, AS SPECIFIED

3'-6

"

4'-0

"

CL

2'-0"

3'-3

"

34" CLEAR

SINK W/KNEE SPACE

OPEN

36"REF.

(N.I.C.)

40" CLEAR

COPIER, N.I.C.

(CABINET MAKER TOVERIFY DIMS. OF

EQUIPMENT WITH OWNER/TENANT)

OPENSHELF

24"18"24"24"18"18"

x 96"

28"x 24"

14"x 42"

14"x 42"

28"x 42"

38"x 24"

36"x 30"

24"x 42"

BASE CABINETS, ASSPECIFIED

COUNTERTOP AND BACK AND SIDE SPLASH, TYP., AS SPECIFIED

WALL CABINETS, ASSPECIFIED

GYPSUM WALL BOARD,AS SPECIFIED

SINK, AS SPECIFIED

2'-1

0"1'

-8"

3'-6

"

8'-0

"

SINK DETAILSCALE: 1/2" = 1'10

24" DEEP24" DEEP

UTIL.CAB.

WALL TILE, AS SPECIFIED

CHAGNON

arc

hit

ec

ture

. i

nte

rio

rs .

de

sig

n-b

uil

d

215

W. S

AN

AN

TON

IO S

T., S

UIT

E 2

104,

SA

N M

AR

CO

S, T

EX

AS

786

66

5

1 2

. 7 5

7 .

9 1

2 7

ww

w.c

hagn

onar

ch.c

om

pcha

gnon

@ch

agno

narc

h.co

m

SHEET NUMBER

REV

.

D

ES

CR

IPTI

ON

DAT

E

2019

ALL

DR

AW

ING

S A

ND

DO

CU

ME

NTS

, AS

INS

TRU

ME

NTS

OF

SE

RV

ICE

, RE

MA

IN T

HE

PR

OP

ER

TY O

F C

HA

GN

ON

AR

CH

ITE

CTU

RE

, PLL

C.

THE

US

E O

R R

EP

RO

DU

CTI

ON

OF

THE

SE

DR

AW

ING

S F

OR

CO

NS

TRU

CTI

ON

OTH

ER

TH

AN

TH

AT W

HIC

H IS

DE

SC

RIB

ED

HE

RE

IN, I

S P

RO

HIB

ITE

D W

ITH

OU

T W

RIT

TEN

CO

NS

EN

T O

F C

HA

GN

ON

AR

CH

ITE

CTU

RE

, PLL

C.

c

SP

OR

TSP

LEX

OFF

ICE

BU

IDLI

NG

- S

UIT

E A

249

SP

OR

TSP

LEX

DR

., D

RIP

PIN

G S

PR

ING

S, T

EX

AS

7862

0

ISS

UE

FO

R C

ON

STR

UC

TIO

N

09.

19.2

019

INTERIORELEVATIONS

A1.2