2019 Sound Insulation Heat Insulation Shear Dowels ... · Impact sound insulation products for...

8
2019 Sound Insulation Heat Insulation Shear Dowels Connecting Elements Strong Products for efficient solutions

Transcript of 2019 Sound Insulation Heat Insulation Shear Dowels ... · Impact sound insulation products for...

Page 1: 2019 Sound Insulation Heat Insulation Shear Dowels ... · Impact sound insulation products for stairs, landings tested according to DIN 4109, EN ISO 10140:3:2010 and heat insulation

2019

Sound Insulation Heat Insulation Shear Dowels

Connecting Elements

Strong Products for efficient solutions

Page 2: 2019 Sound Insulation Heat Insulation Shear Dowels ... · Impact sound insulation products for stairs, landings tested according to DIN 4109, EN ISO 10140:3:2010 and heat insulation

EC2, DIN 4108, DIN 7396 and DIN 4109 page 1

Impact sound insulation products for stairs, landings tested according to DIN 7396

The listed sound products of Pakon AG were tested at the EMPA according to DIN 7396. The sound level measurements according to DIN 7396 are determined according to a standardised test setup and can be used for a statistical energy analysis (SEA) in accordance with DIN EN 12354 and DIN 4109-32 will be applied.

HQW – general technical Approval DIBt Z 15.7-321

TSB – type approvel Prüfamt

Tübingen

NF – Staircase head

NB – Staircase foot

PD – locking dowel

TSP – selfadhesive plates

10/15 mm or Rolls

Page 3: 2019 Sound Insulation Heat Insulation Shear Dowels ... · Impact sound insulation products for stairs, landings tested according to DIN 4109, EN ISO 10140:3:2010 and heat insulation

EC2, DIN 4108, DIN 7396 and DIN 4109 page 2

Impact sound insulation products for stairs, landings tested according to DIN 4109, EN ISO 10140:3:2010 and heat insulation to DIN 4108

HQW – general technicalApproval DIBt Z 15.7-321

Draft ancor – type approval LGA Nürnberg

Single dowel ESD galvanized or Inox

(Quality in S 355 und S 690, Class III + IV)

NURSID SW 24/30 mandrel dowel - Balcony

(Inox 1.4301)

NURSID SW 24 mandrel dowel - facade

(Inox 1.4301)

Page 4: 2019 Sound Insulation Heat Insulation Shear Dowels ... · Impact sound insulation products for stairs, landings tested according to DIN 4109, EN ISO 10140:3:2010 and heat insulation

EC2, DIN 4108, DIN 7396 and DIN 4109 page 3

Wall lock System NURSID KS16 – approvel tested by LGA Nürnberg

Dry connection for precast concrete panels with each other or with props

Wall thickness – from 10 cm

Monting – the side and from above

opening – lockable

Deconstruction capable with mounting box

Tolerance – angular deviation to 4°

+/- 10 mm by 360°

Ball dome with Slotted hole

Page 5: 2019 Sound Insulation Heat Insulation Shear Dowels ... · Impact sound insulation products for stairs, landings tested according to DIN 4109, EN ISO 10140:3:2010 and heat insulation

EC2, DIN 4108, DIN 7396 and DIN 4109 page 4

Schall- Isodorn Typ HQW ST – Set with integrated height adjustment

Schall- Isodorn

Typ HQW SB – Set with top plate for the connection of Steel Balcony

Schall- Isodorn Typ HQW ZD – Set with integrated pull cord

Wall locking dowel

Typ PW – constructive locking dowel for use in masonry walls

Stair dowel

Typ PD – locking dowel

Gripp

Typ A, Typ S – Constructive masonry reinforcement on the role and for the butt made of glass fiber fabric

Page 6: 2019 Sound Insulation Heat Insulation Shear Dowels ... · Impact sound insulation products for stairs, landings tested according to DIN 4109, EN ISO 10140:3:2010 and heat insulation

EC2, DIN 4108, DIN 7396 and DIN 4109 page 5

ZEMBORD - Concrete board for stairs, walls and slabs with connection reinforcement

standard – height 18- 50 cm

WD-P – Joining plate

WD-F – Joining tape

WD-I – Injection

Concrete quality C 45/55

Material thickness 2 cm

Perforation after EC 2

Concrete cover to 20-50 mm

For concrete steel Ø 6 – 28 mm

Butt joint view Butt joint cut

Page 7: 2019 Sound Insulation Heat Insulation Shear Dowels ... · Impact sound insulation products for stairs, landings tested according to DIN 4109, EN ISO 10140:3:2010 and heat insulation

EC2, DIN 4108, DIN 7396 and DIN 4109 page 6

Pakon – plastic profiles

- Own tools- Production in Germany- High quality standard

Page 8: 2019 Sound Insulation Heat Insulation Shear Dowels ... · Impact sound insulation products for stairs, landings tested according to DIN 4109, EN ISO 10140:3:2010 and heat insulation

08/2019