2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392...

24
RETAIL PRODUCT CATALOGUE AUSTRALIA valid from 01.09.2015 H e a l t h y I n d o o r A i r Y E S P L E A S E !

Transcript of 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392...

Page 1: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

RETAILPRODUCT CATALOGUE

AUSTRALIAvalid from 01.09.2015

Hea

lthy Indoor A

ir

Y

E S P L E A SE!

Page 2: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

2

Prices in AUD and exclude GST. Prices valid from 01.09.2015.

All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted. For volume discounts please refer to your pro clima discount structure.

System Products German technology, proven in Australia

®

®

Page 3: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

3Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

Content

Airtightness

INTELLO® 10 INTELLO® PLUS 10INTELLO® PLUS connection strip 11

Fixing components

ORCON® CLASSIC 12TESCON EXTORA® 13TESCON EXTORA® PROFIL 13TESCON EXTOSEAL® 14CONTEGA® IQ Timber 15CONTEGA® IQ Masonry 15TESCON® NAIDEC 15TESCON® VANA 16TESCON® PROFIL 16DUPLEX 16INSTAABOX 17KAFLEX MONO/DUO 18KAFLEX MULTI 18 KAFLEX post 18ROFLEX 50/100/150/200/250/300 19ROFLEX 20 19

Page

Service

New Zealand STUDY 22INTELLO® brochure 23SOLITEX EXTASANA® brochure 23SOLITEX MENTO® brochure 23BRANZ Appraisal No. 815 (TESCON EXTOSEAL®) 23BRANZ Appraisal No. 838 (TESCON EXTORA®) 23BRANZ Appraisal No. 855 (SOLITEX MENTO® 3000) 23BRANZ Appraisal No. 822 (SOLITEX EXTASANA®) 23pro clima contact details 24

Quality control

Blower Door 20WINCON 21WINCON Transport box 21WINCON Tape 21Draeger smoke stick kit 21

Weathertightness

SOLITEX EXTASANA® 5SOLITEX MENTO® 1000 7SOLITEX MENTO® 3000 7SOLITEX MENTO® PLUS 7SOLITEX® UM connect 8

Page 4: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

4Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

SOLITEX EXTASANA®

The optimum weathertightness protection with pro clima

The extremely high diffusion permeability due to the active diffusion function and the high water resistance of the pro clima SOLITEX EXTASANA under all climatic conditions, offers the ultimate weathertightness solution during construction and for the lifetime of the building. The pro clima SOLITEX EXTASANA offers the optimum protection against the leaky building syndrome.

Can be used as an Air BarrierHigh resistance to driving rainHigh tear resistanceHighly diffusion permeable

High resistance to UV ageingQuiet in windy conditionsNew generation wall sarking Optimum weathertightness system

SOLITEX

EXTASANA®

Wall protection membrane

TESCON

Sill tape

EXTOSEAL®

Multi-purpose liquid adhesive

Sealing grommets for cables

KAFLEX mono/duo

Sealing grommets for pipesROFLEX

Weathertight sealing tape

EXTORA®TESCON

Page 5: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

5Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

Application

ADVANTAGES:

High performance monolithic nonporous

membrane; high water resistance; low vapour

resistance; unaffected by wood preservatives;

thermostability above 100 °C; can be exposed

to the Australian elements for 90 days

SYSTEM PRODUCTS:

TESCON EXTORA; TESCON EXTOSEAL;

ORCON CLASSIC; KAFLEX; ROFLEX;

CONTEGA IQ

Wall protection membraneSOLITEX EXTASANA®

APPLICATION: SOLITEX EXTASANA is designed to be used behind most typical cladding systems, provided it is not exposed to the weather or ultra-violet light for a period greater than 90 days.

TECHNICAL DATA:

Cover-fleece + protective-layer: PP microfibre fleeces

Membrane: monolithic TEEE film

MVTR-value: < 0.75 MNs/g

Thickness : 0.60mm ± 0.05mm

Temperature resistance: -40 °C to +100 °C

UV stability and outdoor exposure: 90 days

Water column: 10,000

Surface weight 140 g/m2 ± 5g/m2

ID CODE GTIN LENGTH WIDTH AREA KG/PU PU PU/PAL $/m2 $/UNIT

13323 4026639133236 36.5 m 2.74 m 100 m2 16 1 20 3.90 310.00

13547 4026639135476 36.5 m 1.50 m 55 m2 8.5 1 20 3.90 170.50

ROOF AND WALL UNDERLAYS - External Membranes

Minimum of 150 mm is required at vertical overlaps.

Vertical overlaps

2

installation direction

Fix securely to the frame at 300 mm centres horizontally and vertically.

Roll out and fix membrane

1SOLITEX EXTASANA to be cut at 45° to corners of openings.

Cut membrane at opening

3

SOLITEX EXTASANA to be folded into opening and secured to framing.

Fold membrane into opening

4

5Seal membrane at opening

Apply TESCON EXTOSEAL sill tape to wall openings as per NZBC Acceptable Solution E2/AS1 paragraph 9.1.5.b.

5

5Seal membrane to window joinery

Apply TESCON EXTORA weathertight sealing tape to window joinery.

6

Sealing penetrations

Use pro clima ROFLEX to seal pipepenetrations and pro clima KAFLEX for cable penetrations.

7Use pro clima ORCON CLASSIC to adhere the SOLITEX EXTASANA to rough adjoining structural components or mineral surfaces.

Connecting to rough or mineral surfaces

8

CodeMark: a certification scheme for

building products

Product certification

(CodeMark) is a voluntary

scheme that provides an easily

uderstood and robust way to show

that a building product or system is

code compliant.

A CodeMark-certified product or

construction method must be

accepted by any building consent

authority as complying with the

Building Code, as long as it is used as

specified.

Page 6: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

6Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

High UV resistance, durability

and thermostability

High water resistanceLow vapour resistance

SOLITEX®

Cover fleece

The robust polypropylene microfibre cover fleece is water - resistant and

provides optimum protection against water penetration. It protects the

specialist TEEE-film underneath from damage and UV radiation.

The honeycomb structure provides non-slip properties even when wet.

It is coloured blue to prevent dazzling effect when it is installed.

TEEE-film open, specialist

A stretchable, diffusion-open specialist TEEE-film gives the pro clima

SOLITEX membranes extremely high resistance to water penetration. At

the same time, it allows the water vapour from the inside to pass almost

unrestricted towards the outside.

In addition, the specific properties of the specialist TEEE-film ensure the

excellent wind resistance properties of the pro clima SOLITEX membranes.

Reinforcement material

The tightly meshed PP reinforcement material doubles the overall

strength of the SOLITEX MENTO PLUS membrane. The material is

highly effective at preventing the membrane being penetrated

through accidental treading or nail tearing.

No tent effect

The fact that the pro clima SOLITEX membranes are multi-layered

prevents the tent effect (tent canvases leak at points of contact).

The pro clima SOLITEX membranes can be supported across the whole

surface.

High water resistance - Three layer nonporous diffusion-open polypropylene membrane

High UV resistance - Up to 90 days exposure in Australia

Low vapour resistance - TEEE film for active moisture transport from the inside to the outside

High thermostability - Melting point of the membrane is 200 °C

High durability under all conditions - Membrane as used for vehicle airbags

High rip and nail tear resistance - Durable in high wind zones

High-performance roof and wall sarking

SOLITEX SOLITEX MENTO® 3000

MENTO® PLUS

SOLITEX MENTO® 1000

KAFLEX / ROFLEX

KAFLEX / ROFLEX

SOLITEX EXTASANA®

ORCON®

resistant to ageing

windproof

rainproof

®

TESCON EXTOSEAL®

TESCON EXTOSEAL®

TESCON EXTORA®

TESCON EXTORA®

TESCON EXTORA®

®

Best protection through high performance monolithic nonporous membranes

Weathertightness with pro clima

For more detailed technical information please refer to the pro clima New Zealand Study.

Fix to all framing members with 20 mm largehead flat head

clouts, 8 - 12 mm stainless steel staples or proprietary

underlay fixings. The fixings should at 100 mm - 150 mm

centres.

The membrane must be pulled taut over the framing

before fixing.

Any laps must be no less than 150 mm.

(Please contact pro clima if the roof pitch is < 5°. )

TESCON EXTORA®

150 mm

SOLITEX MENTO®

Roof pitch > 15°

ORCON®

or version 150 mm

SOLITEX MENTO®

TESCON EXTORA®

Roof pitch 10° - 15°

ORCON®

or version

150 mm

SOLITEX MENTO®

SARKING

TESCON EXTORA®

Roof pitch < 10°

> 15° > 10-15° < 10°

Page 7: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

7Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

ROOF AND WALL SARKING - External Membranes

Three and four layer roof sarkingSOLITEX MENTO® FAMILY

Advantages:

High wear-resistance microfibre fleece; very high resistance to driving rain; very high thermal stability; suitable

for use as temporary roof covering as recommended by pro clima

APPLICATION: SOLITEX MENTO is designed to be used with most typical roof cladding systems, provided it is not

exposed to the weather or ultra-violet light for a period greater than 90 days (30 days for SOLITEX MENTO).

ARTICLE ID CODE GTIN LENGTH WIDTH AREA KG/PU PU PU/PAL. $/m2 $/UNIT

SOLITEX MENTO 1000 15048 4026639150486 50 m 1.50 m 75 m2 9 1 30 3.16 237.00

SOLITEX MENTO 3000 13648 4026639136480 50 m 1.50 m 75 m2 11 1 20 3.96 297.00SOLITEX MENTO 3000 15390 4026639153906 50 m 3.00 m 150 m2 22 1 20 3.96 594.00

SOLITEX MENTO 3000 connect 15391 4026639153913 50 m 1.50 m 75 m2 11 1 20 4.60 345.00

SOLITEX MENTO PLUS 13334 4026639133342 50 m 1.50 m 75 m2 13 1 20 4.60 345.00SOLITEX MENTO PLUS 15393 4026639153937 50 m 3.00 m 150 m2 26 1 20 4.60 690.00

SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00

Technical data:

SOLITEX MENTO® 1000

Three layer roof sarking

light sheet ing with mono lith ic TEEE func tion al

mem brane

SOLITEX MENTO® 3000

Three layer roof sarking

very high wear-resistance, high resistance

to driving rain, very high thermal stability

SOLITEX MENTO® PLUS

Four layer reinforced roof sarking

for blowing-in insulation

SOLITEXX MENTO® PLUS

Also available: -tech no logy with

two in teg rated self-ad hes ive zones

11EN 13859-1

ORCON® CLASSICMulti-purpose joint

adhesive in cartridge

or tubular film. For

joints to adjacent

mineral or rough structural components

TESCON EXTORA®

Multi-purpose adhesive

tape for windproof and weathertight sealing of

roof underlays, wall

underlays and other

weathertightness layers

pro clima system products:ROFLEX / KAFLEXSealing grommets for

cables and pipes that

penetrate through the

SOLITEX membrane layer

TESCON® NAIDEC

Double sided butyl rubber tape.

Weathertight nail sealing tape

for the underside of a purlin /

batten on roofs to form a durable seal around nail or

screw penetrations.

TEDo

We

for

ba

duscr

M

ta

we

ro

un

we

MENTO 1000 MENTO 3000 MENTO PLUS

Cover-fleece + protective-layer: PP microfibre fleeces

Membrane: monolithic TEEE film

Reinforcement: – PP

Attribute

Colour: anthracite anthracite anthracite

Surface weight: 115 ±5 g/m2 150 ±5 g/m2 175 ±5 g/m2

Temperature resistance: -40 °C to +100 °C -40 °C to +120 °C -40 °C to +100 °C

MVTR-value: very low very low very low

Thickness: 0.40 ±0.05 mm 0.45 ±0.05 mm 0.60 ±0.10 mm

Tensile strength MD/CD:(based on EN 12311-1)

220 ±15 N/5 cm /

185 ±15 N/5 cm

300 ±20 N/5 cm /

220 ±20 N/5 cm

500 ±30 N/5 cm /

330 ±30 N/5 cm

UV exposure: 30 days 90 days 90 days

Shrinkage: pass pass pass

Flammability Index: 1 1 1

Page 8: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

8Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

ROOF AND WALL SARKING - External Membranes

Four-layer underlay with 3D separation layer and self-adhesive stripSOLITEX® UM

APPLICATION: SOLITEX UM connect is suitable for ventilated or unventilated structures in combination

with any type of roofing or façade materials such as titanium zinc, aluminium, stainless steel, galvanised

steel, copper etc.

ADVANTAGES:

Optimum safety for the roof; highly

diffusion-permeable but with maximum

resistance to driving rain; 3D separation

layer provides increased acoustic insulation

and ventilation between timber sarking

and the metal cladding; very high thermal

stability; integrated self-adhesive strip

SYSTEM PRODUCTS:

TESCON EXTORA; DUPLEX; ORCON CLASSIC;

KAFLEX; ROFLEX; TESCON NAIDEC; TESCON

EXTOSEAL; CONTEGA IQ

TECHNICAL DATA:

Cover-fleece + protective-layer: PP microfibre fleeces

Membrane: monolithic TEEE film

Thickness: 8.0 ±0.5 mm

MVTR-value: 0.30 ±0.10 MNs/g humidity variable

Surface weight: 450 ±10 g/m2

Temperature resistance: -40 °C to +100 °C

Tensile strength MD/CD: 285 ±15 N/5 cm / 215 ±15 N/5 cm

07EN 13859-1

ID CODE GTIN LENGTH WIDTH AREA KG/PU PU PU/PAL $/m2 $/UNIT

13598 4026639135988 25 m 1.50 m 37.5 m2 19 1 10 17.20 602.00

Page 9: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

9Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

High-performance vapour check

the essential element to ensure thermal insulation is perfect

resulting in warmer, drier, healthier homes - all year round

Airtightness with pro clima

summer

winter

Benefits of AirtightnessEnergy retention

Application

ENERGY EFFICIENCY

Reduced air infiltration saves energy and therefore fewer heating / cooling appliances are needed

Keeps your home warm in winter and cool in summer

Solution to reduce Australia‘s overall energy dependence through greater energy efficiency

FREEDOM FROM STRUCTURAL

DAMAGE

Prevents moisture build up in the construction

High drying capacity through the intelligent INTELLO® membrane

In-situ installation verification through WINCON test

HEALTHY INDOOR AIR

Eliminates contamination of the indoor air

Prevents mould and mildew in the construction from internally driven moisture

Enables controlled ventilation

Moisture control in summer and winter

Mark at 1.47 m

Mark the studs using a vivid marker and rigid measure at a distance of 1.47 m from the floor to indicate where the upper edge of the INTELLO® is to be aligned.

1.48 m 1.48 m 1.48 m

1

Stapling

Staple along the entire upper edge of the INTELLO® (1) to every stud first, then on a middle stud (2) run a hand down toward the floor to tighten the INTELLO® and ensure there is a 30 mm return for fixing to floor – apply the first staples from the bottom. Leave a max. distance of 100 - 150 mm between each staple.

23 4

1

100 mm max.

100 mm max.3

Overlap the membranes

Using the printed markings as a guide, overlap the upper sheet by approx. 150 mm and staple both sheets along the entire length first. As before in 3 – on the middle stud tighten the membrane upwards and staple. Ensure junctions between walls and ceilings are “relaxed”. Avoid joining INTELLO® membranes in corners.

150 mm

4

Tape the overlaps

Tape the INTELLO® with TESCON VANA adhesive tape so that it is free of any tension or stress. Position the tape centrally and press firmly to secure using the PRESSFIX. Cut a slit in any folds in the overlapping part of the membrane and re-tape.

5m

Wall and ceiling

Lay the INTELLO® so that it completely covers the walls and ceiling and tape it with TESCON VANA, ensuring that you form an airtight seal.

6

Floor joint

Apply ORCON joint adhesive, forming a continuous bead approx. 5 mm thick on the floor board and lay the membrane in the adhesive bed, leaving an expansion joint. Do not press the adhesive completely flat. Note for all adhesive bonds: The substrate onto which the adhesive isapplied must be load bearing, dry, smooth and free of dust, silicon and grease.

7

Installation box

Cut a hole in the INTELLO® that is the same size as the INSTAABOX. Make the required number of holes in the INSTAABOX and feed the cable through these holes, then align the INSTAABOX and tape it to the INTELLO® with TESCON VANA, ensuring that you form an airtight seal.

8

30 mm

Unroll INTELLO® for the entire wall section allowing sufficient material for “relaxed” corners, returns ontointersecting wall studs and fixing to joinery. Preferably cut wall sections after stapling main sections of INTELLO®. Important: The writing on the INTELLO® should face into the room.

Unroll the membrane

2 30 mm

1.47 m 1.47 m 1.47 m

Page 10: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

10Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

MOISTURE CONTROL AND AIRTIGHTNESS MEMBRANE - Internal Membranes

High-performance vapour check

TECHNICAL DATA:

Fleece: PP microfibre fleeces

Membrane: polyethylene copolymer

Thickness: 0.20 ±0.05 mm

MVTR-value mGTIN/humidity

variable:

40 / 1.25 > 125 MNs/g

Surface weight: 85 ±5 g/m2

Temperature resistance: -40 °C to +80 °C

Tensile strength MD/CD: 130 N/5 cm / 105 N/5 cm

CE certification as per DIN EN 13984.

07EN 13984

ID CODE GTIN LENGTH WIDTH AREA KG/PU PU PU/PAL $/m2 $/UNIT

15467 4026639154675 20 m 1.50 m 30 m2 3.5 1 42 6.00 180.00

13592 4026639135926 50 m 1.50 m 75 m2 7 1 20 5.40 405.00

13594 4026639135940 50 m 3.00 m 150 m2 14 1 20 5.40 810.00

ADVANTAGES:

Maximum protection for your construction;

Optimum prevention against structural

damage and mould, even in the event of

unexpected moisture intrusion; extremely

high humidity-variable diffusion resistance;

MVTR-value > 125 MNs/g in a winter

climate; MVTR-value = 1.25 MNs/g

back-diffusion capacity in summer

SYSTEM PRODUCTS:

TESCON VANA; TESCON PROFIL; ORCON

CLASSIC; INTELLO PLUS connection strip;

KAFLEX; ROFLEX; INSTAABOX; DUPLEX;

CONTEGA IQ

APPLICATION: Can be used as a vapour check and airtightness membrane for all externally diffusion-open

constructions.

High-performance reinforced vapour checkPLUS

ADVANTAGES:

Maximum protection for the insulation;

Optimum prevention against structural

damage and mould, even in the event of

unexpected moisture intrusion; extremely

high humidity-variable diffusion resistance;

MVTR-value > 125 MNs/g in a winter

climate; MVTR-value = 1.25 MNs/g

back-diffusion capacity in summer

SYSTEM PRODUCTS:

TESCON VANA; TESCON PROFIL; ORCON

CLASSIC; INTELLO PLUS connection strip;

KAFLEX; ROFLEX; INSTAABOX; DUPLEX;

CONTEGA IQ

APPLICATION: Can be used as a vapour check and airtightness membrane for all externally diffusion-open

constructions.

07EN 13984

ID CODE GTIN LENGTH WIDTH AREA KG/PU PU PU/PAL $/m2 $/UNIT

15468 4026639154682 20 m 1.50 m 30 m2 4 1 42 6.50 195.00

11367 4026639113672 50 m 1.50 m 75 m2 9 1 20 5.80 435.00

13590 4026639135902 50 m 3.00 m 150 m2 18 1 20 5.80 870.00

TECHNICAL DATA:

Fleece: PP microfibre fleeces

Membrane: polyethylene copolymer

Reinforcement: PP

Thickness: 0.20 ±0.05 mm

MVTR-value mGTIN/humidity

variable:

40 MNs/g / 1.25 > 125 MNs/g

Surface weight: 110 ±5 g/m2

Temperature resistance: -40 °C to +80 °C

Tensile strength MD/CD: 350 N/5 cm / 290 N/5 cm

CE certification as per DIN EN 13984.

ORCON® CLASSICMulti-purpose joint

adhesive in cartridge

or tubular film. For

joints to adjacent

mineral or rough structural components

INSTAABOX

This box allows for

airtight installation

of light switches and power plugs for

wall systems without

service cavity

ROFLEX / KAFLEX

Sealing grommets for cables and pipes that

penetrate through the

INTELLO membrane

layer

TESCON® VANAMulti-purpose adhesive

tape for sealing

membrane overlaps

pro clima system products:

Page 11: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

11Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

MOISTURE CONTROL AND AIRTIGHTNESS MEMBRANE - Internal Membranes

High-performance reinforced vapour check connection strip for ease of installation PLUS connection strip

ADVANTAGES:

Maximum protection for the insulation;

Optimum prevention against structural

damage and mould, even in the event of

unexpected moisture intrusion; extremely

high humidity-variable diffusion resistance;

MVTR-value > 125 MNs/g in a winter

climate; MVTR-value = 1.25 MNs/g

back-diffusion capacity in summer

SYSTEM PRODUCTS:

TESCON VANA; TESCON PROFIL; ORCON

CLASSIC; KAFLEX; ROFLEX; INSTAABOX;

DUPLEX; CONTEGA IQ

APPLICATION: The connection strip is designed to connect the airtightness membranes at junctions

between internal walls and external walls / ceiling.

07EN 13984

ID CODE GTIN LENGTH WIDTH KG/PU PU/BOX PU/PAL $/m2 $/Individual Roll

13315 4026639133151 50 m 300 mm 1.8 2 48 6.25 95.25

TECHNICAL DATA:

Fleece: PP microfibre fleeces

Membrane: polyethylene copolymer

Reinforcement: PP

Thickness: 0.20 ±0.05 mm

MVTR-value mGTIN/humidity

variable:

40 MNs/g / 1.25 > 125 MNs/g

Surface weight: 110 ±5 g/m2

Temperature resistance: -40 °C to +80 °C

Tensile strength MD/CD: 350 N/5 cm / 290 N/5 cm

CE certification as per DIN EN 13984.

APPLICATION

Internal wall

Erect the internal wall allowing an even overhang of the INTELLO® PLUS connection strip on either side of the

internal wall.

PLUS connection strip

Prior to erecting of the internal wall, fix the INTELLO® PLUS connection strip to the junction where

the internal wall meets the external wall using stapes at

200 mm centres. Apply the pro clima ORCONmulti-purpose joint adhesive to connect the INTELLO® PLUS connection strip to the subfloor.

Exterior wall

Floor

All surfaces must be stable, dry, smooth and free of dust, silicon and grease. Sweep or vacuum clGTIN and

wipe all surfaces.

Install the INTELLO® membrane on the inside of the

external wall and uppermost ceiling, where it meets the INTELLO® PLUS connection strip allowing for an

overlap of 20 - 30 mm.

Once all of the INTELLO® membrane is installed, apply

the TESCON VANA multi-purpose adhesive tape to the overlap between the INTELLO® membrane and the

INTELLO® PLUS connection strip to form a continuous airtightness layer.

1 2 3

4 5

ORCON®

CLASSIC

ORCON®

CLASSIC

®

Page 12: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

12Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

ADHESIVES - Fixings

Multi-purpose liquid adhesive

APPLICATION: For connections to rough adjoining structural components or mineral surfaces.

ADVANTAGES:

Exceptionally high cohesion; elastic film;

suitable for bonding of all pro clima

membranes; outstanding adhesion to rough

adjoining structural components or mineral

surfaces

TECHNICAL DATA:

Material: Non-ageing acrylate

polymers without softeners

or halogenated compounds

Installation temperature (unfrozen): -10 °C to +50 °C

Temperature resistance: long term -20 °C to +80 °C

Storage: > -20 °C, cool and dry

ID Code GTIN ITEM VOLUME EFFICIENCY/RANGE KG/PU PU PU/PAL $/Indivdual Unit

14899 4026639148995 cartridge 310 ml bead 5 mm ~ 15 mbead 8 mm ~ 6 m

7.7 20 60 17.50

14900 4026639149008 sausage 600 ml bead 5 mm ~ 30 m bead 8 mm ~ 12 m

7.7 12 60 25.50

Fixing ComponentsFor durable airtightness and weathertightness systems

We provide weather and air tight bonding tapes for fixing of all internal and external surfaces and junctions. The TESCON range is a breakthrough to the Australian market using unique technology patented by pro clima. It adheres to wet and cold surfaces, is diffusion open, highly temperature resistant and easy to apply.

Durable bonding with pro clima

Page 13: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

13Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

APPLICATION: TESCON PROFIL for a secure and permanent weathertight connection between SOLITEX membranes and windows or doors.

TAPES - Fixings

APPLICATION: Multi-purpose adhesive tape for windproof and weathertight sealing of roof underlays, wall sarking and other weathertightness layers.

ADVANTAGES:

Waterproof from the outside; no heating up

necessary; reduces the risk of condensation

and mould; saves time by fast application;

easy to cut; suitable for AUS climate

conditions; thin and flexible; can be applied

to cold and wet surfaces; highly UV

stabilised

ADVANTAGES:

Split release paper for corner of window/door

installations; waterproof from the outside;

no heating up necessary; reduces the risk of

condensation and mould; saves time by fast

application; suitable for AUS climate

conditions; thin and flexible; can be applied to

cold and wet surfaces; highly UV stabilised

ID CODE GTIN LENGTH WIDTH PU KG/PU PU/PAL $/m $/ROLL $/UNIT

13206 4026639132062 30 m 60 mm 10 6 48 1.72 51.60 516.00

13486 4026639134868 30 m 60 mm 20 12 24 1.56 46.80 936.00

13280 4026639132802 30 m 100 mm 3 3 96 2.84 85.20 255.60

14891 4026639148919 30 m 150 mm 2 3.9 96 5.40 129.50 259.00

14892 4026639148926 30 m 200 mm 1 2.9 96 7.20 173.00 173.00

ID CODE GTIN LENGTH WIDTH PU KG/PU PU/PAL $/m $/ROLL $/UNIT

15050 4026639150509 30 m 60 mm 5 6 48 2.10 63.00 315.00

15236 4026639152367 30 m 60 mm 20 12 24 2.00 60.00 1200.00

TECHNICAL DATA:

Carrier material: special fleece based on PP

Release material: siliconized paper

Temperature resistance: long term -40 °C to +90 °C

Installation temperature: from -10 °C

UV stability and outdoor exposure: 90 days

Colour: black

Storage: cool and dry

TECHNICAL DATA:

Carrier material: special fleece based on PP

Release material: siliconized paper

Temperature resistance: long term -40 °C to +90 °C

Installation temperature: from -20 °C

Colour: black

Storage: cool and dry

UV stability and outdoor exposure: 90 days

TESCON EXTORA®

TESCON EXTORA®

Weathertight sealing tape

Weathertight corner sealing tape

Weathertight and durable sealing with pro clima

WatertightCan be applied to damp surfacesVery high adhesion on cold surfacesDiffusion open

Easy to cut with a knifeUV Stability: 90 daysThin and flexible Best performance - saving cost and time

Wall sealing tapes For wall sarking like SOLITEX EXTASANA and other weathertightness layers

Roof sealing tapes For sealing the overlapping of roof sarking like SOLITEX MENTO

big pack*

big pack*

*big pack product only sold per unit.

®

Page 14: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

14Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

TAPES - Fixings

TECHNICAL DATA:

Carrier material butyl rubber with PE film

Release material: siliconized foil in individual strips:

90 / 60 (150mm)

140 /60 (200mm)

Temperature resistance: long term -30 °C to +90 °C

Installation temperature: from -20 °C

Thickness: 1.00 mm

Colour: black

Storage: cool and dry

UV stability and outdoor exposure: 90 days

Sill Tape

APPLICATION: For wall sarking like SOLITEX EXTASANA and other weathertightness layers.

ADVANTAGES:

One piece stretchable Sill tape; no need for

corner moulds; can be applied to damp

surfaces; very high adhesion on cold

surfaces; no heating necessary; highly UV

stabilised; suitable for AUS climate

conditions; best performance; saving cost

and time

ID CODE GTIN LENGTH WIDTH PU KG/PU PU/PAL $/m $/ROLL $/UNIT

14152 4026639141521 20 m 150 mm 2 5 120 6.20 124.00 248.00

14156 4026639141569 20 m 200 mm 2 6.6 84 8.30 166.00 332.00

A

A

TESCON EXTOSEAL®

1Measure vertically up the jamb from the

internal corner of the sill. Minimum 100

mm allowing for 50 mm cover onto the wall

underlay.

Pre-installation measurement

2Cut TESCON EXTOSEAL to appropriate length

(sill length plus required jamb height on either

side).

Cut Sill Tape to length

3Remove first release foil to allow for application

onto sill and jamb framing. Start installing the Sill

Tape from the first pre-installation measurement

of the first jamb. Follow the sill and up the second

jamb. Ensure you apply the Sill Tape tightly into

the corner and smoothly along the sill frame using

the pro clima PRESSFIX.

Installation to framing

4Remove second release foil to allow for

application onto weathertightness layer. Fold and stretch to the face of the weathertightness

layer. Ensure you apply the Sill Tape smoothly using the pro clima PRESSFIX.

Installation to weathertightness layer

5Measure vertically down the jamb andhorizontally across the head trimmer from the

internal corner. Minimum 100 mm allowing for 50 mm cover onto the weathertightness layer.

Repeat installation to jamb and head trimmer

as per steps 3 and 4.

Jamb / Head installation

APPLICATION

Page 15: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

15Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

®

Double sided butyl rubber tape

APPLICATION: As nail sealing tape on the underside of a purlin / batten on roofs to form a durable seal

around nail or screw penetrations.

ADVANTAGES:

Water resistant; suitable for temporary

weathertightening of the roof together with

the pro clima roof sarking without

installation of the roof cladding to allow for

continuous work within the building;

extra-strong due to a reinforcing layer;

contains no bitumen

TECHNICAL DATA:

Carrier material: butyl rubber with PE film

Release material: siliconized paper

Temperature resistance: long term -20 °C to +80 °C

Installation temperature: +5 °C to +35 °C

Thickness: 1.00 mm

Colour: black

Storage: cool and dry

ID CODE GTIN LENGTH WIDTH PU KG/PU PU/PAL $/m $/ROLL $/UNIT

13599 4026639135995 20 m 50 mm 6 8.5 96 1.96 39.20 235.20

13600 4026639136008 20 m 50 mm 24 33 24 1.72 34.40 825.60big pack*

CONTEGA® IQ Window and door connection strips

APPLICATION: CONTEGA IQ is used for an airtight or weathertight connection to windows and door

frames to the airtightness layer, wall underlay or other weathertightness layer.

ADVANTAGES:

Weathertight window and door installation

in accordance with DIN 4108-7, SIA 180 and

OENORM B8110-2; diffusion open,

watertight connection; extremely flexible

and durable connection strip

TECHNICAL DATA:

Carrier material: PP microfibre fleeces

Temperature resistance: from -40 °C to +90 °C

Installation temperature: over -10 °C

Storage: cool and dry

PRODUCT ID CODE GTIN LENGTH WIDTH PU KG/PU PU/PAL $/m $/ROLL

1 self-adhesive strip(For masonry construction)

14897 4026639148971 30 m 90 mm 8 5.5 30 4.75 142.50

2 self-adhesive strip(For timber frame construction)

14896 4026639148964 30 m 90 mm 8 7 30 5.45 163.50

For timber frame construction

with 2 self-adhesive strips

For masonry construction with

1 self-adhesive strip

TAPES - Fixings

*big pack product only sold per unit.

Page 16: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

16Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

TAPES - Fixings

DUPLEX Double sided tape

APPLICATION: Double sided adhesive tape for bonding the overlaps of membranes. Also suitable for

affixing membranes to steel frame structures.

ADVANTAGES: Double sided sealing tape

for the overlap of internal and external

membranes; for fixing of membranes to

steel frame structures; thin and flexible; can

be applied to cold surfaces

TECHNICAL DATA:

Carrier paper: PP reinforcement

Release material: siliconized paper

Temperature resistance: long term from -40 °C to +90 °C

Application temperature: over -10 °C

UV stability and outdoor expo-

sure:

indoor and outdoor use without

direct UV exposure

Colour: clear

Storage: cool and dry

ID CODE GTIN LENGTH WIDTH PU KG/PU PU/PAL $/ROLL $/UNIT

13602 4026639136022 20 m 25 mm 5 0.9 378 15.84 79.20

®

Multi-purpose adhesive tape

APPLICATION: TESCON VANA for a secure and permanent airtight seal of overlaps between INTELLO®

membranes, joints between membranes and smooth, non-mineral surfaces. Also suitable for sealing joints

between wood-based panels.

ADVANTAGES:

Durable airtight sealing inside;

can also be used for penetrations of the

INTELLO®; diffusion open; for airtight sealing

in accordance with DIN 4108, SIA 180

and OENORM B8110-2; thin and flexible;

can be applied to cold surfaces

TECHNICAL DATA:

Carrier material: special fleece made from PP

Release material: siliconized paper

Temperature resistance: long term -40 °C to +90 °C

Installation temperature: from -10 °C

UV stability and outdoor expo-

sure:

indoor use only

Colour: dark blue

Storage: cool and dry

ID CODE GTIN LENGTH WIDTH PU KG/PU PU/PAL $/m $/ROLL $/UNIT

12185 4026639121851 30 m 60 mm 10 7.4 48 1.72 51.60 516.00

11365 4026639113658 30 m 60 mm 20 14.5 24 1.56 46.80 936.00big pack*

Corner sealing tape

ADVANTAGES:

Release paper may be removed in either 3 or

2 individual strips; durable airtight sealing

inside; can also be used for penetrations of

the INTELLO®; diffusion open; for airtight

sealing in accordance with DIN 4108, SIA

180 and OENORM B8110-2;

thin and flexible; can be applied to cold

surfaces

TECHNICAL DATA:

Carrier material: special fleece made from PP

Release material: siliconized paper in individual

strips: 12 / 23 / 25 mm

Temperature resistance: long term from -40 °C to +90 °C

Installation temperature: over -10 °C

UV stability and outdoor expo-

sure:

indoor use only

Colour: dark blue

Storage: cool and dry

®

APPLICATION: TESCON PROFIL for a secure and permanent airtight seal of junctions between INTELLO®

membranes and windows or doors.

ID CODE GTIN LENGTH WIDTH PU KG/PU PU/PAL $/m $/ROLL $/UNIT

12186 4026639121868 30 m 60 mm 5 3.5 96 2.10 63.00 315.00

11398 4026639113986 30 m 60 mm 20 13.8 24 2.00 60.00 1200.00big pack*

*big pack product only sold per unit.

Page 17: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

17Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

All grommets and detail solutions products only available by unit

*big pack product only sold per unit.

Installation box

APPLICATION: This box allows for airtight installation of light switches and power plugs for wall systems

without service cavity.

ADVANTAGES:

Complies with the requirements of DIN

4108-7, SIA 180 and OENORM B8110-2

with regard to airtightness for the use of

standard flush boxes; for up to three flush

boxes; pre-pressed exit points for cables; for

cables up to 20 mm in diameter

INSTAABOX

TECHNICAL DATA:

Material: polyethylene, flexible and extensible

Temperature resistance: –10 °C to +80 °C

Cable diameter: max. 20 mm

Depth: 55 mm

Length / width installation space/

cavern:

260 mm / 130 mm

Length / width over all: 320 mm / 190 mm

ID CODE GTIN PU KG/PU $/PCS $/PU

12181 4026639121813 5 0.13 8.40 42.00

13601 4026639136015 20 0.52 7.50 150.00big pack*

Fixing detail solutionsFor durable airtightness and weathertightness systems

Durable bonding with pro clima

GROMMETS AND DETAIL SOLUTIONS - Fixings

Page 18: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

18Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

GROMMETS AND DETAIL SOLUTIONS - Fixings

KAFLEX multi Multiple cable grommet for up to 16 cables, Ø 6-12 mm

APPLICATION: Cable grommet made from strong and highly flexible EPDM for simple, rapid and permanent

sealing of penetrations for up to 16 cables through the airtightness layer or roof and wall sarking.

ADVANTAGES:

Complete set for up to 16 cables; quick and

secure sealing; indoors or outdoors; extremely

flexible and elastic; efficient and quick

installation; also suitable for penetrations of

roof and wall sarking

TECHNICAL DATA:

Material: EPDM

Temperature resistance: from -40 °C to +120 °C

Installation temperature: over -10 °C

Storage: cool and dry

ID CODE GTIN LENGTH WIDTH PU KG/PU $/PCS $/PU

13630 4026639136305 140 mm 140 mm 2 0.22 26.00 52.00

13634 4026639136343 140 mm 140 mm 20 1 16.60 392.00big pack*

Sealing patch for already installed cables

APPLICATION: KAFLEX post can be used to provide a durable seal to an installed cable that is

already connected. Can be used in combination with internal and external membranes.

ADVANTAGES:

Durable sealing of installed and connected

cables; diffusion open; for airtight sealing

in accordance with DIN 4108, SIA 180 and

OENORM B8110-2; thin and flexible; can be

applied to cold and wet surfaces

KAFLEX post

ID CODE GTIN LENGTH WIDTH PU KG/PU $/PCS $/PU

13635 4026639136350 140 mm 140 mm 5 0.15 8.50 42.50

13636 4026639136367 140 mm 140 mm 20 0.3 6.40 128.00

TECHNICAL DATA:

Material: special fleece made from PP

Release paper: siliconized paper

Temperature resistance: long term -40 °C to +90 °C

Application temperature: from -10 °C

big pack*

*big pack product only sold per unit.

KAFLEX mono/duoSealing grommets for 1 cable, Ø 6-12 mm

Sealing grommets for 2 cables, Ø 6-12 mm

APPLICATION: Sealing grommet made of strong and highly flexible EPDM. Ideally suited for rapid and

permanent airtight sealing of penetrations of cables and pipes through the airtightness layer. Can also be

used outdoors, i.e. for roof and wall sarking.

ADVANTAGES:

High-quality EPDM, extremely flexible and

elastic; cables and pipes can be still be pulled

or pushed without damaging the airtightness

layer; quick and secure sealing; also suitable

for penetrations of roof and wall sarking

TECHNICAL DATA:

Material: special reinforced paper with EPDM

Temperature resistance: -40 °C to +150 °C (EPDM)

Installation temperature: over -10 °C

Storage: cool and dry

PRODUCT ID CODE GTIN LENGTH WIDTH PU KG/PU $/PCS $/PU

KAFLEX mono 13628 4026639136282 145 mm 145 mm 5 0.15 7.20 36.00

KAFLEX mono 13629 4026639136299 145 mm 145 mm 30 0.5 5.50 164.00

KAFLEX duo 13633 4026639136336 145 mm 145 mm 5 0.15 7.20 36.00

KAFLEX duo 13631 4026639136312 145 mm 145 mm 30 0.5 5.50 164.00

big pack*

big pack*

Page 19: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

19Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

GROMMETS AND DETAIL SOLUTIONS - Fixings

ROFLEX 20 multi Multi con duit grom met for up to 9 con duits

APPLICATION: Con duit grom met made of strong and highly flex ible EP DM for simple, rap id and per man ent

air tight feed-throughs of up to 9 pipes through the air tight seal ing lay er or un der the roof.

ADVANTAGES:

Com plete set for up to 9 pipes; se cure bond,

quick and se cure seal ing, in doors or out;

high-qual ity EP DM, ex tremely flex ible and elast ic,

no ex cess bush ing; wa ter proof, also suit able for

pen et ra tions in façades and roof lin ings; pipes

and cables can be still be pulled or pushed

TECHNICAL DATA:

Material: EPDM

Temperature resistance: from -40 °C to +150 °C

Installation temperature: from -10 °C

Storage: cool and dry

ID CODE GTIN LENGTH WIDTH PU KG/PU $/PCS $/PU

12936 4026639129369 200 mm 200 mm 2 0.22 38.90 77.80

*big pack product only sold per unit.

ROFLEX 50 / 100 / 150 / 200 / 250 / 300Sealing grommets for pipes

APPLICATION: Sealing grommet made of strong and highly flexible EPDM. Ideally suited for rapid and permanent

airtight sealing of cable and pipe penetrations through the airtightness layer. Can also be used outdoors, i.e. for

roof and wall sarking by applying the waterproof TESCON EXTORA adhesive tape over grommets.

ADVANTAGES:

High-quality EPDM, extremely flexible and

elastic; cables and pipes can be still be pulled or

pushed without damaging the airtightness layer;

quick and secure sealing; also suitable for

penetrations of roof and wall sarking

TECHNICAL DATA:

Material: EPDM

Temperature resistance: from -40 °C to +150 °C

Installation temperature: over -10 °C

Storage: cool and dry

ID CODE GTIN LENGTH WIDTH FOR DIAMETER PU KG/PU $/PCS $/PU

13608 4026639136084 140 mm 140 mm Ø 50-90 mm 2 ROFLEX 50 0.1 12.00 24.00

13609 4026639136091 140 mm 140 mm Ø 50-90 mm 20 ROFLEX 50 0.4 7.75 155.00

13610 4026639136107 200 mm 200 mm Ø 100-120 mm 2 ROFLEX 100 0.22 14.00 28.00

13613 4026639136138 200 mm 200 mm Ø 100-120 mm 20 ROFLEX 100 1 9.30 186.00

13614 4026639136145 250 mm 250 mm Ø 120-170 mm 2 ROFLEX 150 0.28 19.00 38.00

13612 4026639136121 250 mm 250 mm Ø 120-170 mm 20 ROFLEX 150 1.8 12.00 240.00

13615 4026639136152 300 mm 300 mm Ø 170-220 mm 2 ROFLEX 200 0.4 23.00 46.00

13616 4026639136169 300 mm 300 mm Ø 170-220 mm 20 ROFLEX 200 2 15.00 300.00

13617 4026639136176 450 mm 450 mm Ø 220-270 mm 2 ROFLEX 250 0.7 34.00 68.00

13618 4026639136183 500 mm 500 mm Ø 270-320 mm 2 ROFLEX 300 0.8 42.00 84.00

big pack*

ROFLEX 20 Sealing grommets for pipes, Ø 15-30 mm

APPLICATION: Sealing grommet made of strong and highly flexible EPDM. Ideally suited for rapid and

permanent airtight sealing of penetrations of cables and pipes through the airtightness layer. Can also be

used outdoors, i.e. for roof and wall sarking.

ADVANTAGES:

High-quality EPDM, extremely flexible and

elastic; cables and pipes can be still be pulled or

pushed without damaging the airtightness; secure

bond, quick and secure sealing; also suitable for

penetrations of roof and wall sarking

TECHNICAL DATA:

Material: special reinforced paper with EPDM

Temperature resistance: -40 °C to +120 °C (EPDM)

Installation temperature: over -10 °C

Storage: cool and dry

ID CODE GTIN LENGTH WIDTH PU KG/PU $/PCS $/PU

13605 4026639136053 145 mm 145 mm 5 0.1 8.40 42.00

13606 4026639136060 145 mm 145 mm 30 0.4 6.10 183.00big pack*

big pack*

big pack*

big pack*

Page 20: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

20Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

Airtightness is measurable!

Quality control with pro clima WINCON and Minneapolis Blower Door

WINCON - verification of installation

Verification of the installation of the Intelligent Airtightness System (IAS) is undertaken by using the pro clima WINCON. The simple and easy WINCON test allows air leakage to be identified by depressurising the building.

Blower Door - measuring building performance

A Blower Door is a diagnostic tool which helps locate air leakage within the building envelope. Measurements are performed in pressurised or depressurised buildings, where climatic or other external influences are minimized due to the high pressure difference created by the fan. This allows for a reliable measurement of infiltration rates.

Blower Door Hardware and Software

TECHNICAL DATA:

Frame dimensions: Width 0.71 – 1.14 m

Length 1.32 – 2.43 m

Power source: 230 V / 50 Hz

Maximum airflow volume: Up to 7,200 m3/h

Features: With aluminum frame, DG-700

digital pressure and flow gauge

and software TECTITE Express

Warranty: 1 year

ID Code 15394

GTIN 4026639153944

PU 1

$/PU 8099.00

Page 21: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

21Prices in AUD and exclude GST. Price valid from 01.09.2015. All previous price lists are invalid. Non-binding offer. Terms and conditions apply. Errors excepted.

For volume discounts please refer to your pro clima discount structure.

QUALITY CONTROL

Robust and practical transport box with carry handles.

WINCON Transport box

TECHNICAL DATA:

Material: Plywood

Dimensions: H/860 x B/420 x T/850 mm

ID Code 13640

GTIN 4026639136404

PU 1

$/PU 560.00

10 tubes to visualise air movement, rubber bulb, 4 rubber caps

Draeger smoke stick kit CH 216

ID Code 13642

GTIN 4026639136428

PU 1

$/PU 140.00

For temporary sealing of the WINCON to the construction. Tape can easily be removed after testing

without causing any damage.

WINCON Tape

TECHNICAL DATA:

Roll: 50 mm width / 50 m length

ID Code 13641

GTIN 4026639136411

PU 1

$/PU 18.90

WINCON Installation verification unit

TECHNICAL DATA:

Frame dimensions: 810 x 810 mm

Power source: 230 V / 50 Hz / 4.35 A

Maximum airflow volume: 11,000 m3/h; 9,600 m3/h at 50 Pa

Features: Differential pressure indicator,

speed controller, 5 m power cord

Warranty: 2 years

ID Code 13639

GTIN 4026639136398

PU 1

$/PU 3650.00

Page 22: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

ORDER NOW ++ ORDER NOW ++ ORDER NOW ++ ORDER NOW ++ ORDER NOW +

www.proclima.com.au

KNOWLEDGE

��Seminars

��Workshops

��Technical Support

Weathertight

Windproof

Durable

Waterproof

SOLITEX MENTO

Roof Underlays... optimum protection against

mould and condensation

in your construction

Appraisal No.855 [2014]

Hea

lthy Indoor A

ir

Y

E S P L E A SE!

SOLITEX MENTO 3000 Roof Underlay

protection against

d condensation

construction

HHHeeaa

lltthhy Indoor A

ir

YY

ES P L E A SE!

22

Page 23: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

++ ORDER NOW ++ ORDER NOW ++ ORDER NOW ++ ORDER NOW ++ ORDER NOW

... our knowledge creates solutions for you23

CERTIF

ICATE�O

F�CONFO

RMITY�

This�pro

duct�Cer

tificate�is

�issued�u

nder�Sect

ion�269�o

f�the�Bui

lding�Ac

t�2004�for

:�

Solitex Extasana Wall Underlay

Page 1 of 4�

CodeMark Certification Body

11/10/2012

22/10/2012

11/10/2015

GM-CM30032-

RevB

Global-Mark Pty Ltd, Suite 4.07, 32 Delhi

Road, North Ryde NSW 2113, Australia

www.Global-Mark.com.au

Herve Michoux

Managing Director

Date of issue

Last update

Date of next

re-certification

Certificate Number

The purpose of construction site audits is to confirm the practicability of installing the product; and to confirm the appropriateness and accuracy of

installation instructions.

This certificate is issued by Global-Mark Pty Limited, an independent certific

ation body accredited by the product certification accreditation body (JAS-

ANZ) appointed by the Chief Executive of the Department of Building and Housing under the Building Act 2004. The Department of Building and

Housing does not in any way warrant, guarantee, or represent that the building method or product the subject of this certificate conforms with the New

Zealand Building Code, nor accept any liability arising out of the use of the building method or product. The Department of Building and Housing

disclaims, to the extent permitted by law, all liability (including negligence) for claims of losses, expenses, damages, and costs arising as a result of the

use of the building method(s) or product(s) referred to in this certificate. This Certific

ate may only be reproduced in its entirety

Product Description

Solitex Extasana Wall Underlay is a flexible synthetic wall underlay for use under direct fixed and non-direct fixed wall cladding on

timber and steel framed buildings. The product consists of a non-porous water resistant film laminated between two layers of non

woven spun-bonded polypropylene and is coloured blue on the top surface and grey on the bottom surface.

Product purpose and use

Has been assessed for use as a flexible wall underlay on timber framed buildings within the following scope:

� the scope limitations of NZBC Acceptable Solution E2/AS1 (AMENDMENT 5 - AUGUST 2011 AND ERRATA 2

DECEMBER 2011 ), Paragraph 1.1; and,

� with absorbent wall claddings directly fixed to framing; and,

� with non-metallic, non-absorbent wall claddings directly fixed to frame; and,

� with absorbent and non-absorbent wall claddings installed over an 18 mm minimum drained cavity; and,

� with masonry veneer in accordance with NZBC Acceptable Solution E2/AS1 (AMENDMENT 5 - AUGUST 2011 AND

ERRATA 2 DECEMBER 2011 ); and,

� situated in NZS 3604:2011 Wind Zones up to, and including ‘Very High’.

Has been assessed for use as a flexible wall underlay on steel framed buildings within the following scope:

� the scope limitations of NZBC Acceptable Solution E2/AS1 (AMENDMENT 5 - AUGUST 2011 AND ERRATA 2

DECEMBER 2011 ), Paragraph 1.1 with regards to building height and floor plan area; and,

� with absorbent and non-absorbent wall claddings installed over an 18 mm minimum drained cavity; and,

� with masonry veneer in accordance with NZBC Acceptable Solution E2/AS1 (AMENDMENT 5 - AUGUST 2011 AND

ERRATA 2 DECEMBER 2011 ); and,

� situated in NZS 3604:2011 Wind Zones up to, and including ‘Very High’.

Has been assessed for use as a flexible wall underlay over rigid wall underlays on timber and steel framed buildings within the

following scope:

� the scope limitations of NZBC Acceptable Solution E2/AS1 (AMENDMENT 5 - AUGUST 2011 AND ERRATA 2

DECEMBER 2011 ) (August 2011), Paragraph 1.1 with regards to building height and floor plan area; and,

� with absorbent and non-absorbent wall claddings installed over an 18 mm minimum drained cavity; and,

� with masonry veneer in accordance with NZBC Acceptable Solution E2/AS1 (AMENDMENT 5 - AUGUST 2011 AND

ERRATA 2 DECEMBER 2011 ); and,

� situated in NZS 3604:2011 Wind Zones up to and including ‘Extra High’

Certificate holder

Pro Clima NZ Limited, 27 Port Road, Seaview, Lower Hutt 5010, New Zealand

Compliance with the New Zealand Building Code (NZBC):

If used, designed, installed and maintained in accordance with the statements and conditions of the Installation Guide and this

Certificate, will m

eet, or contribute to meeting the following provisions of the NZBC:

� Clause B2 DURABILITY: Performance B2.3.1(a), not less than 50 years, B2.3.1(b), 15 years and B2.3.2. meets these

requirements.

� Clause E2 EXTERNAL MOISTURE: Performance E2.3.2. When used as part of the cladding system, will contribute to

meeting this requirement.

� Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1. Meets this requirement and will not present a

health hazard to people.

Delhi

ralia

Herve Michou

Managing Dire

dits is to confirm the pract

al-Mark Pty Limited, an inde

ecutive of the Department

warrant, guarantee, or repre

ccept any liability arising out

itted by law, all liability (inclu

s) or product(s) referred to in

ng Code (NZBC

accordance with th

the following prov

ncece B2.3.1(a), not l

RE: PPerformance E2

LDING MMATERIALS

hin the

5 - AUG

nd,

mm minim

E2/AS1 (A

High’.

uildings wit

ENDMENT

ight and flo

er an 18 mm

Solution E2/

ng ‘Very Hig

d wall underla

2/AS1 (AMEND

with regards to

nstalled over a

Acceptable Solu

and including ‘Ex

Fof

y

ed an

lm lam

the bo

ower Hutt 5010, N

ue

ct

det oeutlin

BCth

ovle

E2

S

eG

im(A

witTo

mm2/A

ghla

NDtoau

Ex

Fof

nd

ambo

N

CERTIFICATE�OF�CONFORM

ITY�

This�product�Certificate�is�iss

ued�under�Section�269�of�the

�Building�Act�2004�for:�

Solitex Extasana Wall Underlay

Page 2 of 4�

CodeMark Certification Body

11/10/2012

22/10/2012

11/10/2015

GM-CM30032-

RevB

Global-Mark Pty Ltd, Suite 4.07, 32 Delhi

Road, North Ryde NSW 2113, Australia

www.Global-Mark.com.au

Herve Michoux

Managing Director

Date of issue

Last update

Date of next

re-certification

Certificate Number

The purpose of construction site audits is to confirm the practicability of installing the product; and to confirm the appropriateness and accuracy of

installation instructions.

This certificate is issued by Global-Mark Pty Limited, an independent certification body accredited by the product certification accreditation body (JAS-

ANZ) appointed by the Chief Executive of the Department of Building and Housing under the Building Act 2004. The Department of Building and

Housing does not in any way warrant, guarantee, or represent that the building method or product the subject of this certificate conforms with the New

Zealand Building Code, nor accept any liability arising out of the use of the building method or product. The Department of Building and Housing

disclaims, to the extent permitted by law, all liability (including negligence) for claims of losses, expenses, damages, and costs arising as a result of the

use of the building method(s) or product(s) referred to in this certificate. This Certificate may only be reproduced in its entirety

Subject to the following conditions and limitations:

Design Conditions:

Product specification and incorporation of the Solitex Extasana Wall Underlay into the building design shall be carried out by a

designer / architect / engineer or a building professional who:

� Is qualified to design the buildings covered under the ‘Scope’ of use of this product.

� Has ready access to the relevant technical specifications, NZBC, Standards, details and other information related to

the installation method, including the current version of the Pro Clima NZ Limited Installation Guide for Solitex

Extasana as noted within this Certificate.

Design Information

Timber and Steel Framing

1. Studs must be provided at maximum 600 mm centres. Dwangs must be fitted flush between the studs at maximum 1200 mm

centres.

General

2. Solitex Extasana Wall Underlay is intended for use as an alternative to conventional building papers which are fixed over

timber or steel framed walls in order to limit the entry of wind into building cavities, and to act as a secondary barrier to wind-

driven rain.

3. The material also provides a degree of temporary weather protection during early construction. However, the product will not

make the building weathertight and some wetting of the underlying structure is always possible before the building is closed

in. Hence, the building must be closed-in and made weatherproof before moisture sensitive materials such as wall or ceiling

linings and insulation materials are installed.

4. Solitex Extasana Wall Underlay must not be exposed to the weather or ultra violet light for a total of more than 60 days

before being covered by the wall cladding.

5. Solitex Extasana Wall Underlay is suitable for use under wall claddings as a wall underlay as called up in NZBC Acceptable

Solution E2/AS1 (AMENDMENT 5 - AUGUST 2011 AND ERRATA 2 DECEMBER 2011 ), Table 23 on timber framed

buildings. Solitex Extasana Wall Underlay is suitable for use under cavity based wall claddings as an absorbent synthetic

wall underlay as called up in NZS 2295:2006, Table 2.4 on steel framed buildings. Refer to Table 1.

6. In cavity installations where the cavity battens are installed at greater than 450 mm centres, the wall underlay must be

supported between the battens to prevent the underlay bulging into the cavity space when bulk insulation is installed in the wall

frame cavity in accordance with the requirements of NZBC Acceptable Solution E2/AS1 (AMENDMENT 5 - AUGUST 2011 AND

ERRATA 2 DECEMBER 2011), Paragraph 9.1.8.5.

Structure

7. Solitex Extasana Wall Underlay is suitable for use in all Wind Zones of NZS 3604:2011 up to, and including, ‘Very High’ when

used as a stand-alone flexible wall underlay, and all Wind Zones of NZS 3604:2011 up to, and including, ‘Extra High’ when used

as an overlay for rigid wall underlays.

Durability

8. Solitex Extasana Wall Underlay meets code compliance with NZBC Clause B2.3.1 (a), not less than 50 years for wall underlays

used where the cladding durability requirement or expected serviceable life is not less than 50 years, e.g. behind masonry veneer,

s ce

oux ector

icab

peBn

Wall Underlay into the building design s

e ‘Scope’ of use of this product.

ations, NZBC, Standards, details and

sion of the Pro Clima NZ Limited I

angs must be fitted flush betwee

an alternative to conventiona

wind into building cavities, a

her protection during early

e underlying structure is a

eatherproof before moistuf

d to the weather or ult

nder wall claddings as

1 AND ERRATA 2

e for use under cav

2.4 on steel framed

installed at greate

bulging into the ca

BC Acceptable S

n all Wind Zon

Wind Zones of

iance with

pected se

TE OF CONFORM

is issued under Section269 of the Buil

ding

Wall Underlay

s ce

r

b

eBn

sh

d I

e

naa

y a

tu

lt

s D

avd

tecaS

onof

thse

Mg CERTIFICATE�OF�CONFORMITY�

This�product�Certificate�is�issued�under�Section�269�of�the�Building�Act�2004�for:�

Solitex Extasana Wall Underlay

Page 3 of 4�

CodeMark Certification Body

11/10/2012

22/10/2012 11/10/2015 GM-CM30032-RevB

Global-Mark Pty Ltd, Suite 4.07, 32 Delhi

Road, North Ryde NSW 2113, Australia

www.Global-Mark.com.au Herve Michoux Managing Director Date of issue Last update Date of next re-certification

Certificate Number

The purpose of construction site audits is to confirm the practicability of installing the product; and to confirm the appropriateness and accuracy of

installation instructions. This certificate is issued by Global-Mark Pty Limited, an independent certification body accredited by the product certification accreditation body (JAS-

ANZ) appointed by the Chief Executive of the Department of Building and Housing under the Building Act 2004. The Department of Building and

Housing does not in any way warrant, guarantee, or represent that the building method or product the subject of this certificate conforms with the New

Zealand Building Code, nor accept any liability arising out of the use of the building method or product. The Department of Building and Housing

disclaims, to the extent permitted by law, all liability (including negligence) for claims of losses, expenses, damages, and costs arising as a result of the

use of the building method(s) or product(s) referred to in this certificate. This Certificate may only be reproduced in its entirety

and code compliance with NZBC Clause B2.3.1 (b), 15 years for wall underlays used where the cladding durability requirement is

15 years. Serviceable Life 9. Provided it is not exposed to the weather or ultra-violet light for a total of more than 60 days, and provided the exterior cladding

is maintained in accordance with the cladding manufacturer’s instructions and the cladding remains weather resistant, Solitex

Extasana Wall Underlay is expected to have a serviceable life equal to that of the cladding.

Control of Internal Fire and Smoke Spread

10. Solitex Extasana Wall Underlay has an AS 1530. 2:1993 (including Amendment 1) Flammability Index of � 5 and meets the

requirements of NZBC Acceptable Solution C/AS1 (AMENDMENT 9 – 10 OCTOBER 2011) Part 6, Table 6.2 for surface finish

requirements for suspended flexible fabrics, and therefore it may be used with no restrictions in all buildings.

Outbreak of Fire 11. Solitex Extasana Wall Underlay must be separated from fireplaces, heating appliances, flues and chimneys in accordance with

the requirements of NZBC Acceptable Solution C/AS1 (AMENDMENT 9 – 10 OCTOBER 2011) Part 9 for the protection of

combustible materials.

External Moisture12. Solitex Extasana Wall Underlay must be used behind claddings that meet the requirements of the NZBC, such as those

covered by NZBC Acceptable Solution E2/AS1 (AMENDMENT 5 - AUGUST 2011 AND ERRATA 2 DECEMBER 2011 ), or

claddings covered by a valid BRANZ Appraisal.

13. Solitex Extasana Wall Underlay can be added as a second layer over head flashings in accordance with the requirements of

NZBC Acceptable Solution E2/AS1 (AMENDMENT 5 - AUGUST 2011 AND ERRATA 2 DECEMBER 2011 ), Paragraph 9.1.10.3.

14. Solitex Extasana Wall Underlay, when installed in accordance with the Technical Literature and the CodeMark Certificate will

assist in the total cladding systems compliance with NZBC Clause E2.

Product Installation Information

1. Installation shall always be carried out by:

� A Licensed Building Practitioner (LBP) with a experience in wall underlay installation; or,

� A person with experience in wall underlay installation being supervised by an LBP.

2.The LBP shall also: �

Comply with all of the relevant technical information related to the products use including information contained within the

Solitex Extasana Wall Underlay Installation Guide, titled ‘Pro Clima Solitex Extasana Wall Protection Membrane, Version

2012-09 ID DIG-147’, and the CodeMark Certificate; and,

� Upon completion of the installation, complete and sign a Certificate of Installation and return it to Pro Clima NZ Limited.

11/10/2012r

Date of

y of installingcertificatioand Housbuildingthe buie) for This

ce with NZBC Clause B2.3.1 (b), 15 years for wall underlays used wher

xposed to the weather oor ultra-violet light for a total of more than 60

dance with the claddining manufacturer’s instructions and the cla

is expected to have aa serviceable life equal to that of the claddin

and Smoke Spread Underlay has an AAS 1530. 2:1993 (including Amendment 1

ceptable Solution CC/AS1 (AMENDMENT 9 – 10 OCTOBE

flexible fabrics, anand therefore it may be used with no restr

erlay must be sseparated from fireplaces, heating appli

ceptable Solutution C/AS1 (AMENDMENT 9 – 10 Oay must be e used behind claddings that meet

ution E2/A/AS1 (AMENDMENT 5 - AUGUST

Z Appraisasal. can be adadded as a second layer over head

AMENDMMENT 5 - AUGUST 2011 AND ERR

hen insstalled in accordance with the Tec

mpliancece with NZBC Clause E2. by:

LBPBP) with a experience in wall und

ndderlay installation being supervisnnical information related to the

allation Guide, titled ‘Pro Clim

Mark Certificate; and, mplete and sign a Certificat

RTIFICATE OF COThis product Certificate is issued under Section

Solitex Extasana Wall UnderlaPage 3 of 4

CERTIFICATE�OF�CONFORMITY�

This�product�Certificate�is�issued�under�Section�269�of�the�Building�Act�2004�for:�

Solitex Extasana Wall Underlay

Page 4 of 4�

CodeMark Certification Body

11/10/2012

22/10/2012 11/10/2015 GM-CM30032-

RevB

Global-Mark Pty Ltd, Suite 4.07, 32 Delhi

Road, North Ryde NSW 2113, Australia

www.Global-Mark.com.au Herve Michoux

Managing Director Date of issue

Last update Date of next

re-certification Certificate Number

The purpose of construction site audits is to confirm the practicability of installing the product; and to confirm the appropriateness and accuracy of

installation instructions.

This certificate is issued by Global-Mark Pty Limited, an independent certification body accredited by the product certification accreditation body (JAS-

ANZ) appointed by the Chief Executive of the Department of Building and Housing under the Building Act 2004. The Department of Building and

Housing does not in any way warrant, guarantee, or represent that the building method or product the subject of this certificate conforms with the New

Zealand Building Code, nor accept any liability arising out of the use of the building method or product. The Department of Building and Housing

disclaims, to the extent permitted by law, all liability (including negligence) for claims of losses, expenses, damages, and costs arising as a result of the

use of the building method(s) or product(s) referred to in this certificate. This Certificate may only be reproduced in its entirety

Table 1: NZBC E2/AS1 (AMENDMENT 5 - AUGUST 2011 AND ERRATA 2 DECEMBER 2011) Table 23 Requirements

NZBC E2/AS1 (AMENDMENT

5 - AUGUST 2011 AND

ERRATA 2 DECEMBER

2011) Table 23

Wall Underlay Properties Property Performance

Requirement

Actual Property Performance

Absorbency

� 100 g/m 2

Pass

Vapour Resistance

� 7 MN s/g

Pass

Water Resistance

� 20 mm

Pass

pH of Extract

� 5.5 and � 8

Pass

Shrinkage

� 0.5%

Pass

Mechanical

Edge tear and tensile strength

Edge tear (Average aged):

Machine direction = 234 N

Cross direction = 171 N

Tensile strength (Average aged):

Machine direction = 4.57 kN/m

Cross direction = 3.32 kN/m

Air Barrier

Air resistance: � 0.1 MN s/m 3 Pass. is suitable for use as an air barrier.

End of the document

BRANZ Appraisals

Technical Assessments of products

for building and construction

BRANZ Limited

Private Bag 50 908

Porirua City

New Zealand

Tel: +64 4 237 1170

Fax: +64 4 237 1171

www.branz.co.nz

Readers are advised to check the validity of this Appraisal by referring to the Valid Appraisals listing on the BRANZ website, or by contacting BRANZ.

BRANZ

APPRAISAL

No. 815 (2013)

TESCON EXTOSEAL

SILL TAPE

Pro Clima (NZ) Ltd

PO Box 925

Wellington 6140

Tel: 04 589 8460

Fax: 04 589 8461

Web: www.proclima.co.nz

Email: [email protected]

Appraisal No.815 [2013]

Product

1.1 TESCON EXTOSEAL Sill Tape is a flexible flashing tape for use around framed

joinery openings as a secondary weather resistant barrier.

1.2 The system is installed into and around the framed joinery opening over the building

underlay and exposed frame to cover both the face and edge of the opening framing.

Scope

2.1 TESCON EXTOSEAL Sill Tape has been appraised as a flexible flashing system for

use around window and door joinery openings for buildings within the following scope:

• the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1; and,

• with a risk score of 0-20, calculated in accordance with NZBC Acceptable Solution E2/

AS1, Table 2; and,

• with wall cladding systems complying with NZBC Acceptable Solution E2/AS1 or a valid

BRANZ Appraisal that specifies a flexible flashing system; and,

• with flexible wall underlays compatible with the flashing tape; and,

• situated in NZS 3604 Wind Zones up to, and including, ‘Extra High’.

2.2 TESCON EXTOSEAL Sill Tape has also been appraised as a flexible flashing system

for use around window and door joinery openings for steel framed buildings within the

following scope:

• the scope limitations of NZBC Acceptable Solution E2/AS1, with regards to building

height and floor plan area; and,

• constructed with steel framing complying with the NZBC; and,

• with a risk score of 0-20, calculated in accordance with NZBC Acceptable Solution E2/

AS1, Table 2; and,

• with wall cladding systems covered by a valid BRANZ Appraisal that specifies a flexible

flashing system; and,

• with flexible wall underlays compatible with the flashing tape and steel frame; and,

• situated in NZS 3604 Wind Zones up to, and including, ‘Extra High’.

Building Regulations

New Zealand Building Code (NZBC)

3.1 In the opinion of BRANZ, TESCON EXTOSEAL Sill Tape, if designed, used,

installed and maintained in accordance with the statements and conditions of this

Appraisal, will meet or contribute to meeting the following provisions of the NZBC:

Clause B2 DURABILITY: Performance B2.3.1(b), 15 years and B2.3.2. TESCON

EXTOSEAL Sill Tape meets these requirements. See Paragraphs 8.1 and 8.2.

Clause E2 EXTERNAL MOISTURE: Performance E2.3.2. TESCON EXTOSEAL Sill Tape

contributes to meeting this requirement. See Paragraphs 7.1 - 7.4 and 11.1.

Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1. TESCON

EXTOSEAL Sill Tape meets this requirement and will not present a health hazard to people.

3.2 This is an Appraisal of an Alternative Solution in terms of New Zealand Building

Code compliance. See Paragraph 7.1.

Amended 14 February 2014

y of this Appraisal by referring

N EXTOSEA

dow and do

mitations of

score of 0-2

2; and,

cladding sys

Appraisal tha

ble wall und

in NZS 360

ESCON EXTO

ound window

scope:

cope limitatio

ht and floor pla

structed with s

h a risk score o

S1, Table 2; and

ith wall claddin

ashing system;

with flexible wall

situated in NZS

Building R

New Zealand

3.1In the o

installed and m

Appraisal, will m

Clause B2 DU

EXTOSEAL Sill T

Clause E2 EXT

contributes to m

Clause F2 H

EXTOSEAL Sil

3.2This

Code complia

Taweatoove

rring t

EAdoof2

sad04Ow

olasodng ll

S

R

d o

mmU TTmHls a

Taeaove

BRANZ Appraisals

Technical Assessments of products

for building and construction

BRANZ Limited

Private Bag 50 908

Porirua City

New Zealand

Tel: +64 4 237 1170

Fax: +64 4 237 1171

www.branz.co.nz

Readers are advised to check the validity of this Appraisal by referring to the Valid Appraisals listing on the BRANZ website, or by contacting BRANZ.

BRANZ

APPRAISAL

No. 838 (2013)

TESCON EXTORA

SEALING TAPE

Pro Clima (NZ) Ltd

PO Box 925

Wellington 6140

Tel: 04 589 8460

Fax: 04 589 8461

Web: www.proclima.co.nz

E-mail: [email protected]

Appraisal No.838 [2013]

Product

1.1 TESCON EXTORA Sealing Tape is a flashing tape for use around the head and

jambs (not sills) of framed joinery openings as a secondary weather resistant barrier.

1.2 TESCON EXTORA Sealing Tape can also be used as a jointing tape for rigid wall

underlays (fibre cement sheet and H3.2 treated plywood) before they are over-fixed with a

flexible wall underlay.

1.3 TESCON EXTORA Sealing Tape can also be used to seal flashing upstands to the

wall underlay and as a lap sealing tape for flexible wall and roof underlays.

Scope

2.1 TESCON EXTORA Sealing Tape has been appraised as a flashing tape for use

around the head and jambs of window and door joinery openings for buildings within the

following scope:

• the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1; and,

• with a risk score of 0-20, calculated in accordance with NZBC Acceptable Solution E2/

AS1, Table 2; and,

• with wall cladding systems complying with NZBC Acceptable Solution E2/AS1 or a valid

BRANZ Appraisal that specifies a flexible flashing system; and,

• with a compatible flexible wall underlay fixed directly to the framing or over-fixed over

a rigid wall underlay (fibre cement sheet and H3.2 treated plywood in accordance with

NZBC Acceptable Solution E2/AS1 Paragraph 9.1.7.2); and,

• situated in NZS 3604 Wind Zones up to, and including, Extra High.

2.2 TESCON EXTORA Sealing Tape has also been appraised as a joint sealing tape

for rigid wall underlays (fibre cement sheet and H3.2 treated plywood in accordance with

NZBC Acceptable Solution E2/AS1) which are over-fixed with a flexible wall underlay in

accordance with NZBC Acceptable Solution E2/AS1 Paragraph 9.1.7.2 on buildings within

the following scope:

• the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1; and,

• with a risk score of 0-20, calculated in accordance with NZBC Acceptable Solution E2/

AS1, Table 2; and,

• with wall cladding systems complying with NZBC Acceptable Solution E2/AS1 or a valid

BRANZ Appraisal; and,

• situated in NZS 3604 Wind Zones up to, and including, Extra High.

(Note: Pro Clima (NZ) Ltd offer TESCON EXTORA Sealing Tape as a jointing and flashing

tape for use with rigid air barrier systems that do not require a flexible wall underlay, but

this aspect is outside the scope of this Appraisal. Contact the rigid air barrier system

proprietor for system details including recommended jointing and flashing tapes.)

2.3 TESCON EXTORA Sealing Tape has also been appraised as a lap sealing tape for

flexible wall and roof underlays, and as a tape for sealing metal and uPVC head flashings

to flexible wall underlays in accordance with NZBC Acceptable Solution E2/AS1 Paragraph

9.1.10.3.referring to the Valid Appraisals listing on th w.

EXTOand ja

tatioore o; andddingaisa

patibundptabNZSONndablithscli

k lec

AiC

Sealing Tape

oinery openi

Sealing Tape

et and H3.2

Sealing Ta

sealing tap

listing on thew

Oa

onofdg

abdebS

Ndl

hci

ec

AiC

en

pe2

app

BRANZ AppraisalsTechnical Assessments of products for building and construction

BRANZ LimitedPrivate Bag 50 908

Porirua CityNew Zealand

Tel: +64 4 237 1170Fax: +64 4 237 1171www.branz.co.nz

Readers are advised to check the validity of this Appraisal by referring to the Valid Appraisals listing on the BRANZ website, or by contacting BRANZ.

BRANZ APPRAISAL

No. 855 (2014)

SOLITEX MENTO 3000 ROOF UNDERLAY

Pro Clima (NZ) LtdPO Box 925

Wellington 6140

Tel: 04 589 8460Fax: 04 589 8461Web: www.proclima.co.nzE-mail: [email protected]

Appraisal No.855 [2014]

Product1.1 SOLITEX MENTO 3000 is a synthetic building underlay for use under roof claddings. The product consists of a water resistant film laminated to two layers of polypropylene microfibre cover fleece.

Scope2.1 SOLITEX MENTO 3000 has been appraised for use as a self-supporting roof underlay on buildings within the following scope:• the scope limitations of NZBC Acceptable Solution E2/AS1, Paragraph 1.1 with regards

to building height and floor plan area; and,• with masonry tile roof cladding; and,• with metal tile and profiled metal roof cladding; and, • situated in NZS 3604 Wind Zones up to, and including ‘Extra High’.

Building RegulationsNew Zealand Building Code (NZBC)3.1 In the opinion of BRANZ, SOLITEX MENTO 3000, if used, designed, installed and maintained in accordance with the statements and conditions of this Appraisal, will meet, or contribute to meeting the following provisions of the NZBC:Clause B2 DURABILITY: Performance B2.3.1(a), not less than 50 years, B2.3.1(b), 15 years and B2.3.2. SOLITEX MENTO 3000 meets these requirements. See Paragraphs 9.1 and 9.2.Clause E2 EXTERNAL MOISTURE: Performance E2.3.2. When used as part of the roof cladding system, SOLITEX MENTO 3000 will contribute to meeting this requirement. See Paragraphs 12.1 and 12.2.Clause F2 HAZARDOUS BUILDING MATERIALS: Performance F2.3.1. SOLITEX MENTO 3000 meets this requirement and will not present a health hazard to people. 3.2 This is an Appraisal of an Alternative Solution in terms of the New Zealand Building Code compliance.

d Appraisals listing on the BRANZ website, or by c

MENTO 3000s within the ons of NZBCt and floor proof claddd profiled 604 Wind

gulat

lding n of BordanmeetiY: PeTEX

MOEX 2.2

Bm

ctITEX MENTO 3000 is a syntheconsists of a water resistantver fleece.

RANZ website, or by co

00e

BCp

d

d

ti

BRncti

PeX

OX2B

m

ett

Page 24: 2015-11-10 15414 price-list AUS en 2015 1.3.8 high€¦ · SOLITEX MENTO PLUS connect 15392 4026639153920 50 m 1.50 m 75 m2 13 1 20 5.20 390.00 Technical data: SOLITEX MENTO ® 1000

Hea

lthy Indoor A

ir

Y

E S P L E A SE!

Pro Clima Australia Pty Ltd

PO Box 924GosfordNSW 2250Australia

Phone: 1800 PRO CLIMA (776 254)Web: www.proclima.com.auEmail: [email protected]

2015-09 M15414