201008.034.ProNet.ProNet

download 201008.034.ProNet.ProNet

of 4

Transcript of 201008.034.ProNet.ProNet

  • 8/11/2019 201008.034.ProNet.ProNet

    1/4

    The Extra Expert in your lab:

    UV Detector L-2400

    UV-Visible Detector L-2420Diode Array Detector L-2450

    Outstanding Performance in HPLC Detection

  • 8/11/2019 201008.034.ProNet.ProNet

    2/4

    14

    12

    10

    8

    6

    4

    2

    0

    0 2 4 6 8 10 12 1614 18 20 22 24 26 28 30

    70

    60

    50

    40

    30

    20

    10

    0

    0 0.2 0.4 0.6 0.8 1.0 1.2 1.61.4 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4

    TC = 0.05 s

    TC = 2.00 s

    350

    300

    250

    200

    150

    100

    50

    0

    200 210 220 230 240 250 260 280270 290 300

    Ratio = 2.75

    Perfect UV-Visible Detection for all your needs

    New Standards in HPLCDetection: The L-2400 UVand L-2420 UV-VisibleDetectors

    Both detector types are designed for highest sen-

    sitivity by utilising the double beam photometric

    detector principle in combination with a grating

    monochromator. To improve light intensity and

    detection sensitivity in the visible range, the

    L-2420 UV-Visible detector contains a tungsten

    lamp in addition to the deuterium lamp. Detection

    wavelength is time-programmable for optimum

    detection sensitivity at the absorbance maximum

    of each analyte. If negative peaks should be

    recorded and integrated, e.g. applying indirect UV

    detection for ion chromatography, the polarity

    of the detector signal can be reversed. In

    stopped-flow mode spectra of the analytes

    can be recorded and background-subtracted for

    proper substance identification and selection of

    the optimum detection wavelength. Both detec-

    tors can be operated either by integration into

    the LaChrom Elite system with control throughthe EZChrom Elite chromatography data

    system or as stand-alone modules via the

    optional keypad. In stand-alone mode, several con-

    trol functions using contact signals are available.

    Highest Sensitivityand Resolution

    Advanced optics and innovative electronics com-

    bined in the LaChrom Elite UV-Visible detectors

    ensure minimised RI effects, a large linear

    dynamic range and superior signal to noise

    even with the fastest response times. So lowest

    trace level detection limits and better quantitative

    reproducibility are achieved. The low baseline

    drift makes signal detection insensitive to varia-

    tions in ambient conditions and leads to optimum

    peak integration.A small optical bandwidth ensures

    high spectral resolution of the detectors.

    Fit for Fast Chromatographyand Micro Applications

    The active noise filter combined with a wide

    range of response times, enables optimum

    peak data acquisition even in high-speed chro-

    matography, e.g. using Chromolith columns.

    Narrow, rapidly eluting peaks can be recorded

    with the highest signal to noise ratio whilst main-

    taining peak shape. For all application ranges, from

    micro up to semi-preparative chromatography,

    different optional pre-aligned and easy-to-install

    flow cells are available.

    Extreme spectral resolution of the L-2450 Diode Array Detector

    for precise compound identification

    mAU

    Wavelength (mn)

    Using the 1 mm slit a maximum resolution

    of the benezene spectrum is achieved

    mV

    min

    Equipping the detectors with a micro flow cell

    enables highest sensitivity in trace level micro HPLC

    mAU

    min

    Conditions: L-2400 UV detector equipped

    with a micro flow cell, L-2100 SMASH pump

    Column: Purospher STAR RP-18e 3 m

    150-1 mm

    Sample: 5 PAH compoundsEluent: Methanol/water 80/20

    Flow rate: 50 l/min

    Injection volume: 0.5 l

    Wavelength: 254 nm

    EZChrom Elite UV detector

    setup screen

    High-speed chromatography using a Chromolith column at 5 ml/min:

    Accurate recording of peak shapes if a time constant of 50 ms is selected

  • 8/11/2019 201008.034.ProNet.ProNet

    3/4

    SpecificationsUV Detector L-2400

    UV-Vis Detector L-2420

    Principle Double beam photometric

    detector with grating mono-

    chromator

    Light source L-2400: D2 lamp

    L-2420: D2 lamp + W lamp

    Both: Hg lamp for wavelength

    calibration

    Wavelength range L-2400: 190-600 nm

    L-2420: 190-900 nm

    Noise 0.3 x 10-5AU

    L-2400: at 250 nm

    L-2420: at 250 nm and 600 nm

    Drift 1.0 x 10-4AU/h

    typical 0.4 x 10-4AU/h

    L-2400: at 250 nm

    L-2420: at 250 nm and 600 nm

    Slit width 6 nm

    Response time constant 0.05, 0.1, 0.5, 1, 2, 4, 8 s

    Wavelength time program yes

    Spectrum scan function with background subtraction

    yes

    Polarity change yes

    GLP functions 1. Automatic wavelength

    calibration with different

    D2 lamp and Hg lamp lines

    2. Maintenance logbook: D2,

    W and Hg lamp exchange date,

    lamp energy, total lamp-on

    time, no. of lamp-on switch-

    ings

    Additionally with

    EZChrom Elite:

    - Documentation of instrument

    serial no. and configuration

    - Comprehensive audit trails

    and logbooks

    Safety Leak sensor, Error handling

    Input/Output contact signals - Auto Zero IN

    - Lamp Off IN

    - START IN

    - BUSY OUT

    - ERROR IN/OUT

    Power requirements 24 V DC, 100 W

    Dimensions 340 (W) x 400 (D) x 150 (H) mm

    Diode Array Detector L-2450

    Single beam photometric

    detector with grating mono-

    chromator and 1024 bit diode

    array

    D2 + W lamp

    Hg lamp for wavelength

    calibration

    190-900 nm

    0.75 x 10-5AU

    at 250 nm and 600 nm

    0.5 x 10-3AU/h

    at 250 nm and 600 nm

    1 nm, 4 nm

    0.15 12 s

    by EZChrom Elite

    by EZChrom Elite

    1. Automatic wavelength

    calibration with different

    D2 lamp and Hg lamp lines

    2. Maintenance logbook: D2,

    W and Hg lamp exchange date,

    lamp energy, total lamp-on

    time, no. of lamp-on switch-

    ings

    Additionally with

    EZChrom Elite:

    - Documentation of instrument

    serial no. and configuration

    - Comprehensive audit trails

    and logbooks

    Leak sensor, Error handling

    - START IN

    - BUSY OUT

    - ERROR IN / OUT

    24 V DC, 100 W

    340 (W) x 400 (D) x 150 (H) mm

    The LaChrom Elite Diode Array Detector is

    designed as a single beam photometric detector

    with a grating monochromator. It is equipped

    with a 1024 bit diode array element to sup-

    ply the highest spectral resolution over the

    complete wavelength range. For light sources the

    detector contains both a deuterium and a

    tungsten lamp to ensure maximum sensitivity

    even in the visible range. The selectable optical

    slit width and electronic diode bunching opti-

    mise spectral resolution and sensitivity as

    required for each specific analysis. The setting of

    the electronic noise filter is coupled to the data

    acquisition period. This effectively suppresses

    noise whilst at the same time accurately

    records peak shapes, particularly fast eluting

    peaks in high-speed chromatography.

    3-dimensional chromatographic data is recorded

    and processed in combination with the EZChrom

    Elite chromatography data system.

    The following advanced 3D functions

    are available:

    3D chromatogram data can be background-subtracted and displayed as contour plot,

    as 3D chromatograms, as extracted

    2D chromatograms and extracted spectra.

    Combinations of these display modes can also

    be selected.

    Automatic peak identification by compari-

    son of analyte spectra with library spectra.

    Peak purity assessment by comparison of

    spectra taken at different positions of the

    peak.

    Comparison of spectra and calculation of

    similarity indices.

    Hit list of best fitting spectra with similari-

    ty indices.

    Max Plot: Chromatogram at absorbance

    maximum for each analyte.

    Wavelength bunching: Chromatogram

    calculated over a specified wavelength range

    for optimising sensitivity.

    Ratio Plot: Ratio chromatogram calculated

    from chromatograms at two different wave-

    lengths for assessing peak purity.

    Mixed View screen of EZChrom Elite

    th diode array detector data

    ection of contour plot, spectra,

    chromatogram and 3D chromatogram

    W lamp

    ptics of the L-2450 Diode Array Detector

    howing the Hg lamp for automaticwavelength calibration

    3D-Chromatography with the Diode Array Detector L-2450Peak Identification and Peak Purity Assessment at Lowest Concentration Levels

    Flow cell

    Hg lamp

    Slit

    Grating monochromator

    Photodiode array

    D2 lamp

  • 8/11/2019 201008.034.ProNet.ProNet

    4/4

    Ordering Information

    VWR International GmbH Scientific Instruments

    Hilpertstrae 20A D-64295 Darmstadt

    Fax: +49-6151-3972-101

    www.vwr.com [email protected]

    Designation

    L-2400 UV Detector

    L-2420 UV-Vis Detector

    L-2450 Diode Array Detector

    USB Interface board

    UI Pad kit for UV or UV/Vis Detector

    Power supply: 100 W AC Adaptor

    Organiser

    (System power supply and solvent tray)

    Analog signal output

    for UV or UV/Vis Detector

    Analog signal output for DAD (2 channels)

    e-DIO cable

    for use of START/BUSY/ERROR

    contact signals in stand-alone mode

    System adaptation kits

    for micro and semi-micro applications

    Cat. No.

    890-0402

    890-0422

    890-0452

    890-0702

    890-0740

    890-0872

    890-0852

    890-0510

    890-0560

    890-6145

    On request

    Designation

    Standard flow cell

    (10 mm, 13 l)

    Semi-micro flow cell

    (5 mm, 3.2 l)

    Micro flow cell (5 mm, 0.9 l)

    Chromolith cell (10 mm, 13 l)

    High-pressure semi-micro

    flow cell

    (5 mm, 3.2 l, 150 bar)

    Cuvette holder unit

    L-2450 DAD

    Cat. No.

    890-0550

    890-0554

    890-0556

    use std. cell

    890-0555

    890-0558

    Convenient Maintenance

    All maintenance parts are accessible from the

    front of the instruments. Therefore, the user can

    easily carry out exchange of the detector lamps and

    cleaning or exchange of the flow cell.

    FDA, GMP, GLP functions included

    All detector types are equipped with a mercury lamp for automatic wavelength calibra-

    tion. Using the different spectral lines of deuterium and mercury lamps, wavelength calibration

    can be performed over the whole spectral range of the detectors. In contrast to calibration

    filters (e.g. Holmium oxide filters), which have to be recalibrated themselves periodically, the

    spectral lines of the lamps remain completely constant with time and need not to be recali-

    brated. On the other hand, for wavelength and absorbance calibration with standard solutions

    according to the European Pharmacopoeia, an optional cuvette holder can be supplied.

    The detectors contain a maintenance logbook, which records the exchange date of the

    lamps, the lamp energy, the total lamp on time and the number of lamp on switchings.

    This facilitates regular maintenance and essential documentation. In combination with the

    EZChrom Elite chromatography data system, the complete range of GxP-related

    functions becomes available e.g., recording of the instrument serial number, hardware

    logbooks and audit trails, automatic documentation of the instrument parameters, etc..

    When connected to EZChrom Elite software, full compliance with the FDA rule 21CFR Part

    11 is achieved. Moreover, module qualification (OQ) can be substantially facilitated using

    the optional Auto-Validation software.

    Perfect UV or UV-Visible Detectors for all your needs

    LaChrom and LaChrom Elite are registered trademarks of VWR International,EZChrom Elite is a registered trademark of Scientific Software Inc.,

    Chromolith and Purospher are registered trademarks of Merck KGaA.All other product or company names are trademarks of their respective owners.

    L-2400 UV

    L-2420 UV-Vis

    Cat. No.

    890-0500

    890-0504

    890-0506

    890-0509

    890-0505

    890-0508

    Optional Flow Cells for

    Automatic wavelength accuracy

    check using different spectral lines

    of the deuterium and

    mercury lamps

    UV Detector L-2400 UV-Visible Detector L-2420 Diode Array Detector L-2450